1 User s Manual Power istribution Unit

2 Table of ontents Model List...1 PU Naming onvention... 1 Package ontents... 2 Safety Precautions... 2 Installation... 3 Horizontal Installation... 3 Vertical Installation with rackets... 4 Vertical Installation Keyhole Mounts (0U models only)... 5 ord Retention Tray installation... 5 Meter onfiguration... 5 lectrical Installation... 6 Troubleshooting... 6 Product eatures Technical Specification... 7 asic Series (1U 20)... 7 asic Series (1U 30)... 8 asic Series (0U 10)... 9 asic Series (0U 20) asic Series (0U 30) Metered Series (0U 20) Metered Series (0U 30) Warranty & Service...14

3 Model List: asic Series: PU20HVT8R PU20HVT10R PU20HVT12R PU20HVI8R PU20HVI10R PU20HVI12R PU20HVI12Ra PU30T88R PU30T1010R PU30HVT8R PU30HVT10R PU30HVT12R asic Series (0U): PU10VHVI16 PU10VHVI20 PU20VHVT16 PU20VHVT20 PU20VHVT24 PU20VHVT32 PU20VHVT38 PU20VHVI16 PU20VHVI20 PU20VHVI24 PU20VHVI32 PU20VHVI38 PU30VT14 PU30VT16 PU30VT20 PU30VT28 PU30VT32 PU30VHVT16 PU30VHVT20 PU30VHVT32 PU30VHVT38 Metered Series (0U): PU20MVHVT20 PU20MVHVT30 PU20MVHVT38 PU20MVHVI24 PU20MVHVI30 PU20MVHVI38 PU30MVT24 PU30MVT32 PU30MVHVT20 PU30MVHVT30 PU30MVHVT38 PU Naming onvention: PU XX M V HV T R NT mperage 15, 20, 30 : =asic M: =Metered SW: = Switched NULL: =Horizontal V:= Vertical 3. Rack Space: NULL: =120V HV:= High 200V to 230V 4. Input : NULL: =NM 5-15P / 5-20P 5. Plug Type: T: = Twist (NM L5-L6 Plug) I:= (I 14/20) Number of Outlets followed by xample 8 6. Outlet Number ront Number of Outlets followed by R xample 8R 7. Outlet Number Rear 8. Network Management NT 1. mperage: 2. Series: 1 or information on yberpower products, visit

4 Package ontents PU (1) ord Retention Tray (1/2/3/4 pcs - varies by model) Mounting rackets Horizontal Installation Used (1 set) Vertical Installation Vertical Mounting rackets (1 set) (for 0U models only) Used (1 set) ord Retention Tray Mounting Screws M3 X 6 (4/8/12/16 pcs - varies by model) racket Mounting Screws M4 X 6 (4pcs) Keyhole Mounting Pegs (2pcs) with Screws M4 X 6 (2pcs) (for 0U models only) able Tie (12/ 15/ 21/ 24/ 30/ 36/ 45/ 48/ 57 pcs - varies by model) for ord Retention Tray round Screw M5 X 6 (1 pcs) ocumentation: Use r Man ual ist Power ribu tion Unit User s Manual heck Product Registration ard Product Registration ard efore using, please check to ensure the package contains all the items shown above. If there are missing parts please contact yberpower technical support at or call Safety Precautions Read the following before installing or operating the Power istribution Unit (PU): 1. UTION! Use ONLY the supplied hardware (including screws, pegs and cord retainer clips) to attach the mounting brackets. Using different hardware or improper installations may cause damage that is NOT covered by this warranty. 2. The PU must only be plugged into a three-wire, grounded outlet on a circuit protected by a fuse or circuit breaker. onnection to any other type of power outlet may result in a shock hazard. 3. o not use extension cords or adapters with this PU. 4. Never install a PU, or associated wiring or equipment, during a lightning storm. 5. heck that the power cord, plug, and socket are in good condition. 6. The socket-outlet shall be installed near the equipment and shall be easily accessible. 7. UTION! To prevent the risk of fire or electric shock, this PU should be installed in a temperature and humidity controlled indoor area free of conductive contaminants. o not install this PU where excessive moisture or heat is present. 2 or information on yberpower products, visit

5 Installation Horizontal Installation (1U models only) Step 1 Mounting bracket installation Install the screws (M4 X 6) in holes diagonal from each other. Step 2 PU Mounting Install the PU using fasteners compatible with the rack. 3 or information on yberpower products, visit

6 Vertical Installation with rackets Step 1 Mounting bracket installation Install the screws (M4 X 6) in holes diagonal from each other. Step 2 PU Mounting Install the PU using fasteners compatible with the rack. Vertical Installation with rackets (0U models only) Step 1 Mounting bracket installation ttach the Vertical Mounting rackets to the PU with the 4 supplied racket Mounting Screws (M4 X 6). Step 2 PU Mounting Install the PU using fasteners compatible with the rack. or information on yberpower products, visit 4

7 Vertical Installation with Keyhole Mounts (0U Models) Step 1 Keyhole Mount installation ttach the Keyhole Mounting Pegs to the PU with the 2 supplied racket Mounting Screws (M4 X 6). Step 2 PU Mounting lign the the Keyhole Mounts to the Keyhole Slots on the rack. Insert and slide down to lock firmly into place. ord Retention Tray installation (Optional for both horizontal and vertical installations) djust the length of the ord Retention Tray till the screw hole on the Tray and PU are aligned. ttach the ord Retention Tray to the PU with the 4 supplied ord Retention Tray Mounting Screws (M3 X 6). Tighten the ord Retention Tray with the screw on it. Use the able Ties provided to fasten each power cord to the ord Retention Tray. Meter onfiguration! Note epending on installation method (vertical or horizontal), the L Meter may need to be rotated, before installation, for proper orientation. Use a screwdriver to gently remove the L Meter. Rotate the L Meter 90 degrees, and insert back into the PU. 5 or information on yberpower products, visit

8 lectrical Installation Step 1 Receptacle evaluation nsure that the plug type of your PU unit (e.g. NM 5-15P, NM 520P, NM L5-30P) matches the wall receptacle type that you are using. UTION!! PU must be plugged into a three-wire, grounded wall receptacle only. The wall receptacle must also be connected to an appropriate branch circuit/main with fuse or circuit breaker protection. onnection to any other type of wall receptacle may result in a shock hazard. Step 2 Plug the PU into the wall receptacle Step 3 ttach equipment efore attaching equipment, it is important to calculate the total load that you will be placing on the PU. It is extremely important not to exceed the PU's maximum current load (as outlined in the Specifications section). In order to determine your total load, simply add up the amperage of your devices and ensure that it does not exceed the unit s capacity. Troubleshooting Problem Possible ause PU Outlets do not 1. Open breaker provide power to 2. Loose power cord connected equipment mperage displayed 1. Overload on mperage Meter 2. mperage meter is damaged exceeds the unit s capability (Metered type only) ircuit breaker has tripped 1. Sustained overload 2. xcessive ambient or internal temperatures. 3. aulty breaker Solution Reset reaker check if plug is completely connected. If the problem remains contact tech support. The meter will flash when overloaded. Reduce the load on the PU until the overload is gone. If the problem remains contact tech support. Reset reaker. If the problem remains contact tech support. or information on yberpower products, visit 6

9 asic Series ( 1U 20 ) Product eatures ront View R. Mounting racket ack View Twist Type. Mounting racket. ack Outlets (I ). ack Outlets (I ). ircuit reaker. xternal Site round. Power ord. ord Retention Tray I Type. xternal Site round. Inlet (I ). ord Retention Tray. Mounting racket. ack Outlets (I ). ircuit reaker Technical Specifications PU20HVI8R PU20HVI10R PU20HVI12R PU20HVI12Ra PU20HVT8R PU20HVT10R PU20HVT12R Model Name Input Max urrent 20 Regulatory erated Input urrent 16 ircuit reaker Plug Type Power ord Length NM L6-20P I I (8) I (10) I (12) I (2)/13(10) Output Max urrent Outlet Type(Quantity) I (2)/13(6) I (2)/13(8) I (12) Indicators L Indicators N/ Meter Readout N/ Physical imension (WxxH) 17.5" x 1.5" x 1.75" / 44.5 x 3.81 x 4.45 cm nvironmental Humidity ltitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32 to 95 Non-Operating 5 to 113 Safety pprovals ertifications Warranty 7 TL (test followed UL ) RoHS Lifetime or information on yberpower products, visit

10 asic Series ( 1U 30 ) Product eatures ront View Normal Type R NK1 NK2 NK1. Mounting racket. L Indicators. ront ank 1 Outlets High Type R NK1 NK2. Mounting racket. L Indicators ack View Normal Type NK2.Mounting racket.ircuit reaker (ank 1).Rear ank 2 Outlets.xternal Site round.ircuit reaker (ank 2). Power ord.ord Retention Tray High Type NK2 H NK1 H.Mounting racket.ank 2 Outlets.ank 1 Outlets.ircuit reaker (ank 2).ircuit reaker (ank 1).xternal Site round. Power ord H.ord Retention Tray Technical Specifications Model Name PU30HVT8R PU30HVT10R PU30HVT12R PU30T88R PU30T1010R Input 100 ~ 125 V Max urrent 30 Regulatory erated Input urrent 24 ircuit reaker Plug Type Power ord Length 20 x 2 16 x 2 NM L5-30P NM L6-30P 12 f t 100~125 V NM 5-20R(16) NM 5-20R(20) I (2)/13(6) I (2)/13(8) I (12) Output Max urrent Outlet Type(Quantity) Indicators L Indicators Meter Readout ank1(rn) ank2(rn) N/ Physical imension (WxxH) 17.5"x2.25"x1.75" / 44.5x5.72x4.45 cm 17.5"x1.5"x1.75" / 44.5x3.81x4.45 cm nvironmental Humidity ltitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32 to 95 Non-Operating 5 to 113 Safety pprovals ertifications Warranty TL (test followed UL ) RoHS Lifetime or information on yberpower products, visit 8

11 asic Series ( 0U 10 ) Product eatures ront View ack View. Inlet (I ). ircuit reaker. xternal Site round. ront Outlets. ord Retention Tray. racket Screw Hole. Keyhole Mount Peg Technical Specifications PU10VHVI16 PU10VHVI20 Model Name Input Max urrent 10 Input urrent ircuit reaker Plug Type I 14 Power ord Length Output Max urrent 10 Outlet Type(Quantity) I (16) I (4)/13(16) Indicators L Indicators N/ Meter Readout N/ Physical imension (WxxH) 1.75"x1.5"x24" / 4.45x3.81x60.96 cm 1.75"x1.5"x36" / 4.45x3.81x91.44 cm nvironmental Humidity ltitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32 to 95 Non-Operating 5 to 113 Safety pprovals ertifications Warranty 9 TL (test followed UL ) RoHS Lifetime or information on yberpower products, visit

12 asic Series ( 0U 20 ) Product eatures ront View ack View Twist Type:. Power ord. ircuit reaker. xternal Site round. ront Outlets. ront Outlets. ord Retention Tray. racket Screw Hole. Keyhole Mount Peg High Type:. Inlet (I ). ircuit reaker. xternal Site round. ront Outlets. ront Outlets. ord Retention Tray Technical Specifications Model Name PU20VHVT16 PU20VHVT20 PU20VHVT24 PU20VHVT32 PU20VHVT38 PU20VHVI16 PU20VHVI20 PU20VHVI24 PU20VHVI32 PU20VHVI38 Input Max urrent 20 Regulatory erated Input urrent ircuit reaker Plug Type Power ord Length NM L6-20P I Output Max urrent Outlet Type(Quantity) I (16) I (4)/13(16) I (4)/13(20) I (8)/13(24) I (8)/13(30) Indicators L Indicators N/ Meter Readout N/ Physical imension (WxxH) 1.75" x 1.5" x 24" / 4.45 x 3.81 x cm 1.75" x 1.5" x 36" / 4.45 x 3.81 x cm 1.75" x 1.5" x 48" / 4.45 x 3.81 x cm 1.75" x 1.5" x 60" / 4.45 x 3.81 x cm 1.75" x 1.5" x 70" / 4.45 x 3.81 x cm nvironmental Humidity ltitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32 to 95 Non-Operating 5 to 113 Safety pprovals ertifications Warranty TL (test followed UL ) RoHS Lifetime or information on yberpower products, visit 10

13 asic Series ( 0U 30 ) Product eatures ront View ack View Normal Type: Normal Type:. Power ord. xternal Site round. ircuit reaker (ank 1). ircuit reaker (ank 2). ord Retention Tray. ront Outlets(ank1). ront Outlets(ank2). Power ord. racket Screw Hole. Keyhole Mount Peg High Type:. Power ord. ircuit reaker (ank 1). ircuit reaker (ank 2). xternal Site round. ront Outlets(ank 1). ront Outlets(ank 2). ord Retention Tray High Type:. Power ord. racket Screw Hole. Keyhole Mount Peg Technical Specifications PU30VT14 PU30VT16 PU30VT20 PU30VT28 PU30VT32 Model Name PU30VHVT16 PU30VHVT20 PU30VHVT32 PU30VHVT38 Input 100 ~ 125 V Max urrent 30 Regulatory erated Input urrent 24 ircuit reaker Plug Type Power ord Length 20 x 2 16 x 2 NM L5-30P NM L6-30P 100 ~ 125 V 30 NM 5-20R(14) NM 5-20R(16) NM 5-20R(20) NM 5-20R(28) NM 5-20R(32) 30 Output Max urrent Outlet Type(Quantity) I (16) I (4)/13(16) I (8)/13(24) I (8)/13(30) Indicators L Indicators N/ Meter Readout N/ Physical imension (WxxH) 1.75"x2.25"x24" / 4.45x5.72x60.96 cm 1.75"x2.25"x36" / 4.45x5.72x91.44 cm 1.75"x2.25"x48" / 4.45x5.72x121.92cm 1.75"x2.25"x60" / 4.45x5.72x cm 1.75"x2.25"x70" / 4.45x5.72x cm 1.75"x1.5"x24" / 4.45x3.81x60.96 cm 1.75"x1.5"x36" / 4.45x3.81x91.44 cm 1.75"x1.5"x60" / 4.45x3.81x cm 1.75"x1.5"x70" / 4.45x3.81x cm nvironmental Humidity ltitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32 to 95 Non-Operating 5 to 113 Safety pprovals ertifications Warranty 11 TL (test followed UL ) RoHS Lifetime or information on yberpower products, visit

14 Meter Series ( 0U 20 ) Product eatures ront View ack View Twist Type:. Power ord. ircuit reaker. xternal Site round. ront Outlets. Meter Readout. ront Outlets. ord Retention Tray. racket Screw Hole. Keyhole Mount Peg High Type:. Inlet (I ). ircuit reaker. xternal Site round. ront Outlets. Meter Readout. ront Outlets. ord Retention Tray Technical Specifications Model Name PU20MVHVT20 PU20MVHVT30 PU20MVHVT38 PU20MVHVI24 PU20MVHVI30 PU20MVHVI38 Input Max urrent 20 Regulatory erated Input urrent ircuit reaker Plug Type Power ord Length NM L6-20P I I (4)/13(16) I (6)/13(24) I (8)/13(30) I (4)/13(20) I (6)/13(24) I (8)/13(30) Output Max urrent Outlet Type(Quantity) Indicators L Indicators N/ Meter Readout mperage Physical imension (WxxH) 1.75" x 1.5" x 48" / 4.45 x 3.81 x cm 1.75" x 1.5" x 60" / 4.45 x 3.81 x cm 1.75" x 1.5" x 70" / 4.45 x 3.81 x cm nvironmental Humidity ltitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32 to 95 Non-Operating 5 to 113 Safety pprovals ertifications Warranty TL (test followed UL ) RoHS Lifetime or information on yberpower products, visit 12

15 Metered Series (0U 30) Product eatures ront View ack View. Power ord. racket Screw Hole. Keyhole Mount Peg I Normal Type:. Power ord. xternal Site round. ircuit reaker (ank 1). ircuit reaker (ank 2). ord Retention Tray I H I I. ront Outlets (ank 1). Meter Readout (ank 1) H. Meter Readout (ank 2) I. ront Outlets (ank 2) High Type:. Power ord. ircuit reaker (ank 1). ircuit reaker (ank 2). xternal Site round. ront Outlets (ank 1). Meter Readout (ank 1). Meter Readout (ank 2) H. ront Outlets (ank 2) I. ord Retention Tray H I Technical Specifications PU30MVHVT20 PU30MVHVT30 PU30MVHVT38 PU30MVT24 PU30MVT32 Model Name Input 100 ~ 125 V Max urrent 30 Regulatory erated Input urrent 24 ircuit reaker Plug Type Power ord Length 20 x 2 16 x 2 NM L5-30P NM L6-30P 100 ~ 125 V NM 5-20R(24) NM 5-20R(32) I (4)/13(16) I (6)/13(24) I (8)/13(30) Output Max urrent Outlet Type(Quantity) Indicators L Indicators N/ Meter Readout 2 mperage Physical imension (WxxH) 1.75"x2.25"x60" / 4.45x5.72x cm 1.75"x2.25"x70" / 4.45x5.72x cm 1.75"x1.5"x48" / 4.45x3.81x cm 1.75"x1.5"x60" / 4.45x3.81x cm 1.75"x1.5"x70" / 4.45x3.81x cm nvironmental Humidity ltitude Temperature Operating 0 to 95% Non-condensing Non-Operating 0 to 95% Non-condensing Operating 0ft to 10,000ft Non-Operating 0ft to 50,000ft Operating 32 to 95 Non-Operating 5 to 113 Safety pprovals ertifications Warranty 13 TL (test followed UL ) RoHS Lifetime or information on yberpower products, visit

16 Product Registration Thank you for purchasing a yberpower product. Prompt product registration entitles coverage under the Limited Warranty and onnected quipment uarantee, and also allows the opportunity to be notified of product enhancements, upgrades, and other announcements. Registration is quick and easy at under "Support". Need dditional Help? eel free to contact our Tech Support department with installation, troubleshooting, or general product questions. yberpower Technical Support th ve ast, Suite 400 Shakopee, MN Toll-free: (877) Limited Warranty Read the following terms and conditions carefully before using the yberpower PU(the Product ). y using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty (together referred to as this Warranty ). If you do not agree to the terms and conditions of this Warranty, you should return the Product for a full refund prior to using it. Who is Providing this Warranty? yberpower Systems (US), Inc. ( yberpower ) provides this Limited Warranty. What oes This Warranty over? This warranty covers defects in materials and workmanship in the Product under normal use and conditions. What is the Period of overage? This Warranty is for as long as the original owner owns the Product. Who Is overed? This warranty only covers the original purchaser. overage ends if you sell or otherwise transfer the Product. How o You et Service? 1. all us at (877) or write to us at yber Power Systems (US), Inc., th ve.., ST 400, Shakopee, MN or send us an message at claims@cpsww.com for instructions. 2. When you contact yberpower, identify the Product, the Purchase ate, and the item(s) of onnected quipment. Have information on all applicable insurance or other resources of recovery/payment that are available to the Initial ustomer and Request a laim Number. 3. You must provide a purchase receipt (or other proof of the original purchase) and provide a description of the defect. 4. Pack and ship the product to yberpower and, if requested, the item(s) of onnected quipment, a repair cost estimate for the damage to the onnected quipment, and all claim forms that yberpower provides to you. Show the laim Number on the shipping label or include it with the product. You must prepay all shipping costs, you are responsible for packaging and shipment, and you must pay the cost of the repair estimate. What Will We o To orrect Problems? yberpower will inspect and examine the Product. If the Product is defective in material or workmanship, yberpower will repair or replace it at yberpower's expense, or, if yberpower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, yberpower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is required). Who Pays or Shipping? We pay when we send items to you; you pay when you send items to us. or information on yberpower products, visit 14

17 What re Some Things This Warranty oes Not over? 1. This Warranty does not cover any software that is damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records, or the reinstallation of software. 2. This Warranty does not cover or apply to: misuse, modification, operation or storage outside environmental limits of the Product or the equipment connected to it, nor for damage while in transit or in storage, nor if there has been improper operation or maintenance, or use with items not designed or intended for use with the Product, such as laser printers, appliances, aquariums, medical or life support devices, etc. What re the Limitations? 1. This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets (including compliance with electrical and safety codes of the most current electrical code), without the use of any adapters or other connectors. 2. The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy-chained together in serial fashion with any extension cords, another Product or device similar to the Product, surge suppressor, or power tap. ny such installation voids the Limited Warranty. 3. The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license, instruction manual, or warnings provided with the Product and the equipment connected to it. 4. The Product must have been used at all times within the limitations on the Product's V capacity. 5. The sole and exclusive remedies of the Initial ustomer are those provided by this Warranty. ontact Information yberpower Systems, Inc th ve ast, Suite 400 Shakopee, MN Toll-free: (877) yberpower is the warrantor under this Limited Warranty. You may also contact yberpower on the web at 15 or information on yberpower products, visit

18 yber Power Systems, Inc. K

User Manual. Power Distribution Unit th Ave E #400, Shakopee, MN K

User Manual. Power Distribution Unit th Ave E #400, Shakopee, MN K User Manual Power istribution Unit 4241 12th ve #400, Shakopee, MN 55379 1-877-297-6937 www.psww.com K01-0000083-00 Table of ontents Model List...1 PU Naming onvention... 1 Package ontents... 2 Safety

More information

User s Manual Step-Down Transformer

User s Manual Step-Down Transformer User s Manual Step-Down Transformer OL6KRT2UTFHWIO OL10KRT2UTFHWIO OL6KRT2UTFHWIOR OL10KRT2UTFHWIOR CyberPower Systems (USA), Inc. 4241 12th Avenue East Suite 400 Shakopee, MN 55379 Phone: 877-297-6937

More information

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2

More information

Power Distribution Unit

Power Distribution Unit Power Distribution Unit USER'S MANUAL Copyright 2018 Cyber Power Systems, Inc. All rights reserved. K01-0000545-02 Table of Contents Model List...1 Safety Precautions...1 Introduction...2 Package Contents...2

More information

SMART APP ONLINE STEP-DOWN TRANSFORMER

SMART APP ONLINE STEP-DOWN TRANSFORMER SMART APP ONLINE STEP-DOWN TRANSFORMER INSTALLATION AND OPERATION MANUAL OL6KSTF OL10KSTF SAVE THESE INSTRUCTIONS Please read this manual and follow the instructions for installation and operation. 2018

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

G5 PDU Installation Guide

G5 PDU Installation Guide G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form

More information

User s Manual Legend SB425 K

User s Manual Legend SB425 K User s Manual Legend SB425 K01-1120007-00 TABLE OF CONTENTS IMPORTANT SAFETY WARNINGS.. 1 INSTALLING YOUR UPS SYSTEM.. 2 - UNPACKING..2 - HARDWARE INSTALLATION GUIDE. 2 BASIC OPERATION...2 - FRONT PANEL

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Zonit μats TM Users Guide μats1-lv Version 1.2

Zonit μats TM Users Guide μats1-lv Version 1.2 Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

User s Manual Legend SB500R UPS K

User s Manual Legend SB500R UPS K User s Manual Legend SB500R UPS K01-1120008-00 Legend SB500R Uninterruptible Power System TABLE OF CONTENTS IMPORTANT SAFETY WARNINGS. 2 INSTALLING YOUR UPS SYSTEM.. 3 - UNPACKING.3 - HARDWARE INSTALLATION

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Tripp Lite Network-Grade Power Distribution Units (PDUs)

Tripp Lite Network-Grade Power Distribution Units (PDUs) T N L P P L T O N U L L T N # 9 5-3 0 8 4 Tripp Lite Network-rade Power istribution Units (PUs) Tripp Lite Network-rade PUs are extremely reliable multiple-outlet strips that distribute power from a UPS

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Start Here. All-in-One Printer. Print Copy Scan

Start Here. All-in-One Printer. Print Copy Scan Start Here All-in-One Printer Print Copy Scan Note: A USB 2.0 cable is required to connect your Kodak All-in-One printer to your Windows or Macintosh OS computer. Available in the Kodak online store or

More information

Pulse LED Instruction Guide

Pulse LED Instruction Guide PARTS LIST Light Fixture Aquarium Frame Mounts Instruction Guide WARNING: To guard against injury, basic precautions should be observed, including the following: A) READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

More information

Bluetooth Ceiling Fan Control with App Owner's Manual

Bluetooth Ceiling Fan Control with App Owner's Manual READ AND SAVE THESE INSTRUCTIONS 0 Model Number RCBT00 Bluetooth Ceiling Fan Control with App Owner's Manual -Speed Hand Held Transmitter Single Light Supplied with Receiver Includes Light Dimming Selection

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt POWER AVAILABILITY 2U POD USER MANUAL Power Output Distribution 120 Volt TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................................... 1 GLOSSARY OF SYMBOLS..................................................

More information

Rack Power Distribution Unit AP7530, AP7540

Rack Power Distribution Unit AP7530, AP7540 Rack Power Distribution Unit AP7530, AP7540 Description This booklet provides information on installing and operating the singlephase Rack Power Distribution Units (PDUs) AP7530 and AP7540. AP7530 AP7540

More information

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A PDU16-AV 20A AC PDU WITH POWER MONITOR 2U Rack Mount PDU with Overload Protection & Power Monitoring 2U high Horizontal Mounting unit designed to provide versatile hook-up for the distribution of AC power

More information

WallVIEW PTZ Systems WallVIEW 50i PTZ, WallVIEW 100 PTZ and WallVIEW 70 PTZ Pan/Tilt/Zoom Camera Systems

WallVIEW PTZ Systems WallVIEW 50i PTZ, WallVIEW 100 PTZ and WallVIEW 70 PTZ Pan/Tilt/Zoom Camera Systems Camera and Electronic Products for Integrators Installation and User Guide WallVIEW PTZ Systems WallVIEW 50i PTZ, WallVIEW 100 PTZ and WallVIEW 70 PTZ Pan/Tilt/Zoom Camera Systems Figure 1: WallVIEW Systems

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland

More information

User s Manual PR5000LCDRTXL5U

User s Manual PR5000LCDRTXL5U User s Manual PR5000LCDRTXL5U K01-0000523-01 IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions. Please read and follow all instructions carefully during installation and operation

More information

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

DISCONTINUED PRODUCT DISCONTINUED PRODUCT Important Safety Instructions This manual contains important safety instructions that should be followed during the installation and maintenance of this product. Please read this manual thoroughly before

More information

Liebert MicroPOD 230V

Liebert MicroPOD 230V AC Power For Business-Critical Continuity Liebert MicroPOD 230V User Manual TABLE OF CONTENTS 1.0 IMPORTANT SAFETY INSTRUCTIONS...........................................1 2.0 GLOSSARY OF SYMBOLS..................................................2

More information

Installation and Operation

Installation and Operation Installation and Operation G-Type Rack Power Filter G50NETB2 G50NETB-20A2 120 Vac 15 A 20 A General Information Product Features The APC AV G-Type G50NETB2 and G50NETB-20A2 Rack Power Filters protect high-performance

More information

Owner s Manual. Desktop Charging Stations. USB Charging (Model: CSD1006USB) AC Charging with Surge Suppression (Model: CSD1006AC)

Owner s Manual. Desktop Charging Stations. USB Charging (Model: CSD1006USB) AC Charging with Surge Suppression (Model: CSD1006AC) Owner s Manual Desktop Charging Stations USB Charging (Model: CSD1006USB) AC Charging with Surge Suppression (Model: CSD1006AC) Este manual esta disponible en español en la página de Tripp Lite: www.tripplite.com

More information

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT 12 Volt Power Supplies Installation Manual 9-Port RET9PT 18-Port RET18PT INTRODUCTION Congratulations! The RET9PT 9-Port 12V Power Supply is the perfect solution for your larger security installations.

More information

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown TOT Series Manual North American and International Models - without optional faceplate Receptacle Panel of International Models, CE model shown North American Models Table of Content 1. Important Safety

More information

User Manual Back-UPS BE650MC

User Manual Back-UPS BE650MC User Manual Back-UPS BE650MC Inventory Back-UPS ES 650 bu075b This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive

More information

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product. LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

CUBE Micro Station User Guide

CUBE Micro Station User Guide CUBE Micro Station User Guide Models TVS10AC CUBE Micro Station - User Guide 1 of 23 How To Use This Guide This User Guide is a resource to provide you guidelines and best practices as you begin using

More information

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage

More information

4 Port USB Power Hub. Model: JH-800 USER MANUAL

4 Port USB Power Hub. Model: JH-800 USER MANUAL by 4 Port USB Power Hub Model: JH-800 USER MANUAL BEFORE INSTALLING AND USING THE PRODUCT, PLEASE READ THE INSTRUCTIONS THOROUGHLY, AND RETAIN THEM FOR FUTURE REFERENCE. Charging Port PRODUCT OVERVIEW

More information

Perle MCR200 Installation Guide

Perle MCR200 Installation Guide Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT

More information

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication

More information

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt POWER AVAILABILITY 2U POD USER MANUAL Power Output Distribution 230 Volt TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................................... 1 GLOSSARY OF SYMBOLS..................................................

More information

Product Documentation

Product Documentation Product Documentation Emanate PowerPath TM TempTag PPT-300 Date: April 12, 2016 Document Number: PPT200-001 R1.4 Emanate Wireless, Inc. 11145 Windsor Rd. Ijamsville, MD 21754 Telephone: 844-EMANATE Email:

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

User Manual for: CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL and PowerPanel Software

User Manual for: CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL and PowerPanel Software User Manual for: CPS320SL / CPS375SL / CPS500SL / CPS575SL / CPS650SL and PowerPanel Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: http://www.cyberpowersystems.com/faq_sl.htm TABLE OF CONTENTS

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

INSTALLATION TIPS CAN BE FOUND AT:

INSTALLATION TIPS CAN BE FOUND AT: User Manual for and PowerPanel Plus Software User Manual ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com/faqs.htm TABLE OF CONTENTS Description...1 Determining Power Requirements...1

More information

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models TOT Series Manual North American CE and UK Models CE Models UK Models North American Models Table of Content 1. Important Safety Instructions 2. Description Shipping Carton & Packing Material Placement

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:

More information

INSTALLATION TIPS CAN BE FOUND AT:

INSTALLATION TIPS CAN BE FOUND AT: User Manual for CPS1250AVR and PowerPanel Plus Software User Manual ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: http://www.cyberpowersystems.com/faqs.htm TABLE OF CONTENTS Description.1 Determining Power

More information

Power Supply (48Vdc, 2.5A)

Power Supply (48Vdc, 2.5A) Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

LED FOLDING WORKLIGHT TM

LED FOLDING WORKLIGHT TM LED FOLDING WORKLIGHT TM LED LIGHT POWERSTRIP USB CHARGING ITM. / ART. 689211 Model: LM55812 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly

More information

UPS READY POWER DISTRIBUTION ASSEMBLY

UPS READY POWER DISTRIBUTION ASSEMBLY UPS READY POWER DISTRIBUTION ASSEMBLY FOR TRAFFIC CABINETS with LED Signals INSTALLATION & OPERATOR S MANUAL VERSION 1.2 1 Note The instructions contained in this manual are not intended to cover all of

More information

ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:

ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: User Manual for CPS625AVR with USB Interface and PowerPanel Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com TABLE OF CONTENTS Description..1 Hardware Installation Guide

More information

CMSA-100 Manual. Cinema Media Server Automation

CMSA-100 Manual. Cinema Media Server Automation CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

HPE Intelligent Power Distribution Unit Installation Instructions

HPE Intelligent Power Distribution Unit Installation Instructions HPE Intelligent Power Distribution Unit Installation Instructions Important safety information For important safety, environmental, and regulatory information, see Safety and Compliance Information for

More information

Network Camera. Quick Guide DC-B1203X. Powered by

Network Camera. Quick Guide DC-B1203X. Powered by Network Camera Quick Guide DC-B1203X Powered by Safety Precautions English WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:

ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: User Manual for CPS1100AVR with USB / Serial Interface and PowerPanel Plus Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com/faqs.htm TABLE OF CONTENTS Determining Power

More information

Power Rack 58. EXT-PS5-8R User Manual.

Power Rack 58. EXT-PS5-8R User Manual. Power Rack 58 EXT-PS5-8R User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

SERVICE MANUAL MODEL SSW-321-X

SERVICE MANUAL MODEL SSW-321-X SSW-321-X-ISSUE 4.0 SERVICE MANUAL FOR MODEL SSW-321-X STAINLESS STEEL WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,

More information

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:

More information

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours IS Series Manual IS O Power IS Series Toroidal Isolation Power Conditioning 19 Pro Series Rack Mount (RK) Faceplate IS O Power IS Series Toroidal Isolation Power Conditioning 17 Consumer Series (C) Faceplate

More information

HDMI Extender over Cat5e/6

HDMI Extender over Cat5e/6 Statement Thanks for purchasing this product, please read this user manual carefully before using this product.in the constant effort to improve our product, we reserve the right to make functions or parameters

More information

User Guide. Control Box. RoscoLED TM.

User Guide. Control Box. RoscoLED TM. RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260

More information

AC4G-D User s Manual

AC4G-D User s Manual AC4G-D User s Manual Entire contents of this manual 2004 Active Cool Ltd. Ashkelon, Israel. Reproduction in whole or in part without permission is prohibited. Active Cool and AC4G-D are registered of Active

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

NT1B-300 Rack Installation Instructions

NT1B-300 Rack Installation Instructions The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies

More information

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926 User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926 Preface Read this user manual carefully before using this product. Pictures shown in this

More information

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System USER MANUAL Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System 614-06762-00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

The PST-6. Owners Manual 1

The PST-6. Owners Manual 1 The PST-6 Owners Manual 1 Introduction Thank you for purchasing the Furman Power Station-6 Power Conditioner. For over 30 years, Furman has pioneered the development of AC power products for the most demanding

More information

User s Guide. POWERVAR Single Phase Power Conditioners

User s Guide. POWERVAR Single Phase Power Conditioners POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant

More information

USER S MANUAL PFC SINEWAVE SERIES OR1000PFCRT2U/OR1500PFCRT2U/ OR2200PFCRT2U

USER S MANUAL PFC SINEWAVE SERIES OR1000PFCRT2U/OR1500PFCRT2U/ OR2200PFCRT2U EN USER S MANUAL PFC SINEWAVE SERIES OR1000PFCRT2U/OR1500PFCRT2U/ OR2200PFCRT2U K01-0000488-02 IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions. Please read and follow all instructions

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

VADDIO /CANON BU-SERIES PTZ CAMERAS

VADDIO /CANON BU-SERIES PTZ CAMERAS Camera and Electronic Products for Integrators Installation and User Guide VADDIO /CANON BU-SERIES PTZ CAMERAS Canon BU-45H Outdoor & BU-50H Indoor PTZ Cameras including Vaddio accessories for easy integration

More information

Model DMX24DIM Installation and Operations Manual

Model DMX24DIM Installation and Operations Manual DOUG FLEENOR DESIGN, Inc. Model DMX24DIM Installation and Operations Manual Doug Fleenor Design, Inc. 396 Corbett Canyon Road Arroyo Grande, CA 93420 (805) 481-9599 Voice and FAX Manual revision November

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team INSTRUCTION MANUAL PREFACE We are thrilled that you have chosen Zen Space. Congratulations, you have selected one of the most advanced and sophisticated Power Adjustable Workstations available today. Our

More information

powerbrite led Lighting Systems & Modules

powerbrite led Lighting Systems & Modules powerbrite led Lighting Systems & Modules Instructions for Model PowerBrite LED #1643, 1644, 1645, 1646, 1647, 1648 Important Safety Instructions... Page 2 Installation Instructions... Page 4 Warranty...

More information

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors: TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Configuration 6. DMX512 Connections 7. How to Set the Unit 8. Troubleshooting

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

Model: VA/230W UPS Backup System

Model: VA/230W UPS Backup System IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of unit.

More information

Enphase S-Series Microinverter and Engage Cable Safety

Enphase S-Series Microinverter and Engage Cable Safety SAFETY Enphase S-Series Microinverter and Engage Cable Safety Important Safety Information (S280-60-LL and S230-60-LL) This document contains important instructions to use during installation of the Enphase

More information

Nevco Indoor LED Scoreboard Installation Manual

Nevco Indoor LED Scoreboard Installation Manual Nevco Indoor LD Scoreboard Installation Manual Retain this manual in your permanent file. Rev. 8/6/09 135-014 Installation Instructions Installation consists of three steps, Unpacking the quipment, Scoreboard

More information

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8 DVI KVM Extra Long Range Extender Over One CAT5 EXT-DVIKVM-ELR User Manual Release A8 Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND

More information

Operating Instructions

Operating Instructions Model No.: CV0101-N041-000 Operating Instructions Thanks for purchasing our product. Please be sure to read this instruction manual carefully before using our product. Introduction Grandbeing s CV0101-N041-000

More information

Vocia. Page Active Relay Module (PARM-1) Operation Manual

Vocia. Page Active Relay Module (PARM-1) Operation Manual Vocia Page Active Relay Module (PARM-1) Operation Manual Biamp System 9300 SW Gemini Drive, Beaverton, OR 97008 U.S.A. (503) 641-7287 www.biamp.com table of contents Vocia Page Active Relay Module (PARM-1)

More information

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

M215 Safety (M LL-S22-IG / S23-IG / S24-IG) M215 SAFETY M215 Safety (M215-60-2LL-S22-IG / S23-IG / S24-IG) Important Safety Information This document contains important instructions to use during installation of the Enphase M215 Microinverter. To

More information

Speaker Selectors Models SSW-L4 EX and SSW-L6 EX. User Manual. SSW-L4 EX (bottom) and SSW-L6 EX (top)

Speaker Selectors Models SSW-L4 EX and SSW-L6 EX. User Manual. SSW-L4 EX (bottom) and SSW-L6 EX (top) Speaker Selectors Models SSW-L4 EX and SSW-L6 EX User Manual SSW-L4 EX (bottom) and SSW-L6 EX (top) Table of Contents Important Safety Precautions...2 What s Included...2 Introduction... 3 Front Panel...

More information

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA Management Interface The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place

More information

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V Variable ISI Channel CLE1000 Hardware Operation Manual for CLE1000 H2K CLE1000 H2V CLE1000 S2 CLE1000 A2 Rev 2.5 May 2015 Introduction... 2 Safety Instruction... 2 1. General... 4 Features... 4 2. Connectors

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information