Introduction. General Ratings
|
|
- Samuel Johnston
- 5 years ago
- Views:
Transcription
1 Introduction Storage temperature Operating temperature Humidity Weight Dimensions Screw terminal wire gauge Supply voltage Supply currents Maximum baud rate Unit Mounting Housing o -20 to +70 C o Allows computers and peripheral devices to share data Converts RS232 to RS485 and RS485 to RS232 LED Indicators of port activity Wide power supply options The FMT-DS/C data splitter is an interface device which allows computers, PLCs and peripherals to share data. The FMT-DS/C has three serial interfaces, two are RS232 and one is RS485. Note that the RS485 interface has provision for tri-stating the transmitter. The RS485 transmitter will be enabled whenever data is received on either of the RS232 ports. The transmitter will remain enabled for approximately 7mS after the last character is sent. No RS232 handshaking lines are required. General Ratings 0 to 50 C 10-90% Typically 110g 50 mm wide 75 mm long 53 mm high Up to 12AWG, 2.5mm fine stranded wire 10-30vac or 10-50vdc Typically 20 24VDC bps The unit can be mounted on all standard NS32 and NS35 DIN rail profiles to EN50 045, EN and EN standards Polymide PA6.6, EMG50 Phoenix Contact Inflammability class V0 (UL94) Page 1.
2 Connection Details Tx Rx Device C (RS232) Device A (RS485) -Tx +Tx -Rx +Rx 9 8 GND 0v PORT C LED Descriptions Label TxA TxB TxC RxA RxB RxC POWER 7 TxD RxC RxB RxA PORT A 6 RxD RS232 TxC TxB TxA RS485 5 RxD- RxD+ TxD- TxD+ GND VDC - 3 SUPPLY IN 2 A.C. SUPPLY 10-3 D.C. SUPPLY 10-5 POWER + 1 GND RxD TxD 0v GND Description Lights when data is being transmitted from port A Lights when data is being transmitted from port B Lights when data is being transmitted from port C Lights when data is being received on port A Lights when data is being received on port B Lights when data is being received on port C Lights when power is applied to FMT-DS/C Device B (RS232) Rx Tx Page 2.
3 Terminal Descriptions Screw Terminal No Description GND (earth) Supply In Supply In Link Setting Receive RS232 data (input) Transmit RS232 data (output) Ground Receive RS485 data -VE connection (input) Receive RS485 data +VE connection (input) Transmit RS485 data -VE connection (output) Transmit RS485 data +VE connection (output) Ground Receive RS232 data (input) Transmit RS232 data (output) Ground Nominal Rating Maximum Rating (not continuous) N/A N/A 10-5DC or 10-3AC Notes Earth connection (used to ground the various cable screens). Pins 1-2 are linked together. Pins 3-4 are linked together. If using DC supply then the supply is 10-5DC biplolar (it can be connected either way round). If using AC supply then the supply is 10-3AC. PORT C RS232 data in. PORT C RS232 data out. PORT C RS232 connection. PORT C RS232 Ground connection. PORT A RS485 data in. PORT A RS485 data in. PORT A RS485 data out. PORT A RS485 data out.. PORT A RS485 ground. PORT B RS232 data in. PORT B RS232 data out. PORT B RS232 connection. PORT B RS232 Ground connection. Under the cover of the FMT-DS/C will be founder seven jumper link switches. These can be accessed by carefully removing the clear cover. The functions of the links are listed below: Link LK1 LK2 LK3 LK4 LK5 LK6 LK7 Function Transmitt Terminator Receive Terminator Data Routing Data Routing Transmitter Tri-State Receiver Enable Transmit lines bias enabled Link ON 150 ohm resistor fitted between Tx+ and Tx ohm resistor fitted between Tx+ and Tx-. Type A routing. Type A routing. Transmitter Tri- Stated when not transmitting. RS485 port will not receive while transmitting data. Applies 820 ohm pull up and pull bown resistors to the transmit lines. Link OFF No resistor fitted. No resistor fitted. Type B routing. Type B routing. Transmitter permanently enabled. Receive permanently enabled. No bias applied. Comments Fit terminating resistors to the devices at each end of the RS485 cable run only. Fit terminating resistors to the devices at each end of the RS485 cable run only. See Data Routing section. Both LK3 and LK4 must be moved together. See Data Routing section. Both LK3 and LK4 must be moved together. Set this link to off if the RS485 transmitter is connected to one or more receivers. Set the link to on if the RS485 transmitter is connected to other transmitters in a multidrop network. Set this link to off if it is necessary to receive and transmit simultaneously. Applies passive biasing to the RS485 transmitter. The recommended approach is to apply bias on one (or at most two) transmitters, preferably in the middle of the cable run. Bias is not required if the transmitter is permanently enabled. Page 3.
4 Effects of the Link Settings on the RS485 port Tx Rx LK5 LK6 Data Routing Rx- LK2 Rx+ LK7 Tx- Note: These two switches are a representation of the function of LK7 LK1 Data routing is set with links LK3 and LK4 to be either Type A or Type B. With Type A routing, data transmitted by and device is received by the other two. With Type B routing, data transmitted by device A is received by both device B and device C. Data transmitted by device B is only received by device A, not by device C, and data transmitted by device C is only received by device A, not by device C. PORT C DATA ROUTING ON TYPE A PORT C PORT A PORT B PORT A 5V Tx+ PORT B DATA ROUTING ON TYPE B Page 4.
5 Cable Specifications and Maximum Lengths The cable used for the RS485 connection should consist of two twisted pairs with either individual or overall screen. Suitable cables include Belden types 9729, 9829, For the RS232 connections a multi-core with overall shield is recommended, Belden type * The maximum cable length for RS232 applications is 15m. * The maximum cable length for RS485 applications is 1200m (1.2Km). Page 5.
6 Data Sheet Issue: 1.10 Date: 10 May 2005 Order Codes Part Number FMT-DS/C COLTER GROUP COLTER PRODUCTS LIMITED UNIT 7, ZONE C CHELMSFORD ROAD INDUSTRIAL ESTATE DUNMOW ESSEX CM6 1HD Telephone: + 44 (0) Fax: + 44 (0) sales@coltergroup.co.uk Web Site: Copyright 1999 The unit described on this datasheet is designed and manufactured in Great Britain by Products Ltd. Products reserve the right to amend these specifications and the user is asked to check the validity of the data sheet prior to use Page 6.
RM4-2NO & RM8-2NO 180x77x65 (RM8 size) RM8-1C. RM8-2C & RM16-2C 202.5x77x68 (RM8 size) 8 or changeover. Yes. Yes.
Introduction Products offer a range of relay modules designed to provide Programmable controllers, PLC's and Microprocessor systems a power switching capability to their standard solid state outputs. The
More informationTRP-C06H User s Manual
TRP-C06H User s Manual 2-Port RS-232 to RS-422/485 Isolated Converter Printed Feb.2007 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Hinge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,
More informationMoxa TCC-100 Series User s Guide
Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The
More informationMoxa TCC-100 Series Hardware Installation Guide
Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide
More informationTRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0
TRP-C08M USB To 4 RS232/422/485 Isolated Converter User s Manual Printed Jun. 2013 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,
More informationR507 I.S. Interface Module User Manual
R507 I.S. Interface Module R507 I.S. Interface Module User Manual Contact Mercury HMI Ltd George House Derwent Road Malton North Yorkshire YO17 6YB Page 2 of 14 Tel: +44 (0) 1653 697200 Fax: +44 (0) 8700
More informationUser s Manual Printed Sep Rev 1.2
TRP-C08M USB To 4 RS232/422/485 Isolated Converter User s Manual Printed Sep. 2014 Rev 1.2 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More informationUSER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 1000P Non-Powered Short Haul Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1000PA Doc. #022031UA Revised 2/17/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
More informationWiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.
3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series
More informationConverter Box Data Sheet
Page 1 from 6 Functions of the converter box The converter box is used to adapt physically two interfaces and to separate them galvanicly. It is configured as follows: Two interface slots can be used to
More informationRTU560 Remote Terminal Unit Connections and Settings
Remote Terminal Unit Connections and Settings Communication Unit 560CMG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CMG10 1KGT 150 645 Operation
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More informationMEV Limited USB232/485 INSTRUCTION MANUAL
MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5 LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual
More informationFlexMulti Setup Guide
FlexMulti 1553 Setup Guide MAX Technologies 2016 MAX Technologies 2016 Page 2 Document History Version Date Note 1.0 10-2016 Initial version MAX Technologies 2016 Page 3 Acronym AC Alternating Current
More informationDIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL
DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL REVISED: 8/12/13 DGH CORPORATION PO BOX 5638 MANCHESTER, NH 03108 TELEPHONE: 603-622-0452 FAX: 603-622-0487 WEB: www.dghcorp.com The information
More information205 CPU NETWORK ADAPTER F2-UNICON
205 CPU NEWORK ADAPER F2-UNICON Network Adapter he F2-UNICON Network Adapter is used to place Automationdirect.com DL205 CPUs (except D2-230 and D2-250) on a RS-422 or RS-485 multi-drop network. he Network
More informationHuddleCamHD Serial Joystick Controller Model Number: HC-JOY-G3
HuddleCamHD Serial Joystick Controller Model Number: HC-JOY-G3 Joystick Keyboard Installation & Operation Manual Easy pan, tilt & zoom controls for any RS-232, RS485, RS422 VISCA, Pelco-P or Pelco-D protocol
More informationSubmittal Data Sheet WAGO Node for itm
The WAGO Node integrates ancillary equipment into the Intelligent Touch Manager (itm) DCM601A71 with the use of DI, DO, AI and AO signals. It provides monitoring and control of non-daikin equipment via
More informationICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter
ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus
More informationTCNM-ACBB1 Installation Manual
The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is
More informationNote: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function
Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200
More informationWeight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1
8 Panel Specifications: In this section, you will be given all of the information you need to install the panel. Before actually installing the OP-9001 panel, it may be helpful to examine the specifications
More informationMGate 4101-MB-PBS Series
MGate 4101-MB-PBS Series 1-port Modbus RTU/ASCII-to-PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus and PROFIBUS Supports PROFIBUS DP V0 slave Supports Modbus RTU/ASCII
More informationMED102A. Industrial Serial to Single-mode Fiber Converter
MED102A - 0708 pg. 1 / 5 MED102A Industrial Serial to Single-mode Fiber Converter Data Rates up to 115.2 kbps 9 Mile (15 km) Range 10 to 48 VDC Input Voltage Wide Operating Temperature 2000V Isolation
More informationCONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual
5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:
More informationAccessories IC690ACC900
(IC690ACC900) datasheet Features Provides the IC69* programmable controllers with an interface to devices that use the RS- interface. Allows connection to programming computer without a Work Station Interface
More informationTRP-C08X. USB To 4 RS232/422/485 Converter. User s Manual
TRP-C08X USB To 4 RS232/422/485 Converter User s Manual Printed Sep. 2014 Rev 1.2 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax:
More informationISOLATED RS-232 TO RS-422/485 CONVERTER
QUICK START GUIDE ICD400A ISOLATED RS-232 TO RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Specifications Complies with FCC Class B and CE requirements. Withstands
More informationIntegrity Instruments
Integrity Instruments P.O. Box 451 Order Phone 800-450-2001 Pine River Minnesota Fax Phone 218-587-3414 56474 USA Tech Phone 218-587-3120 http://www.integrityusa.com 485-25A High Speed RTS Enabled RS-232
More informationInStep Plus Hardware Manual (Instep with Expansion Board) For Main board Rev 1 and Expansion board Rev 0
Design, Application and Service of Electronics in Industry InStep Plus Hardware Manual (Instep with Expansion Board) For Main board Rev 1 and Expansion board Rev 0 (To be used in conjunction with the appropriate
More informationClassic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers
B2 Analog Brain Board Features Intelligent digital processors. Serial data link operates at selectable baud rates from 300 baud to 38.4 Kbaud Optomux units can be configured for either multidrop or repeat
More informationProduct Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M
USB to Optical Adapter Industrial Isolated RS- 232/422/485 Product Manual Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M 2 USB-COMi-SI-M Product Manual Revision History Revision Date
More informationVirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual
VirtualSCADA USB to RS422/485 Isolated Converter User Manual Revision 1.01.00 Page 1 (15) Table of contents Warranty and support... 3 Product return... 3 1 About the VirtualSCADA USB to RS422/485 Converter...
More informationABB Drives. User s Manual RS-485 Adapter Board FRSA-00
ABB Drives User s Manual RS-485 Adapter Board FRSA-00 Table of Contents 1 INTRODUCTION... 2 1.1 Overview... 2 1.2 Technical Data of RS-485 Link... 2 1.3 RS-485 Bus Topology... 2 2 INSTALLATION... 2 2.1
More informationManual Fiber Optic Interfaces
Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it
More informationEasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:
EasySync Ltd ES-R-2x01-M RS232 to RS422 / RS485 Converter User Guide Document Reference No.: ES_000011 Issue Date: 2009-04-10 The ES-R-2001-M and ES-R-2101-M provide a simple method of converting RS232
More informationPT 3-PB-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode
More informationCS485. User s Manual. Version ZYPEX, Inc.
CS485 User s Manual Version 2.0 2003 ZYPEX, Inc. Table of Contents Product Description 1 CS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter
More informationEX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)
EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an
More informationInstallation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter
Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter Introduction of USB-COMi and USB-COMi-SI The USB-COMi and USB-COMi-SI Industrial Single RS-422/485 Adapters are designed to make
More informationADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual
ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following
More informationFeatures and Benefits. Certifications
TCF-142 Series RS-232/422/485 to fiber converters Features and Benefits Ring and point-to-point transmission Extends RS-232/422/485 transmission up to 40 km with single-mode (TCF- 142-S) or 5 km with multi-mode
More informationEX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card
EX-45362 & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card Congratulation on your purchasing this high performance 2-Port RS232/422/485 3-in-1 Serial PCIe Host Adapter. The adapter is high speed PCIe
More informationT1K MODBUS Base Controller Specifications
Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationProcess displays For current and voltage
Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma
More informationTRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2
TRP-C08S USB To 1* RS232 and 1*RS422/485 Isolated Converter User s Manual Printed Jun. 2007 Rev 1.2 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,
More informationVL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features
Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL
More informationSDM-8AO. Expansion Module 8 analog outputs. Manufactured for
Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSER-4485-SI-M USER S MANUAL
SER-4485-SI-M USER S MANUAL 2017 May Edition Titan Electronics Inc. Web: www.titan.tw The computer programs provided with the hardware are supplied under a license. The software provided should be used
More informationPT 2X2-24DC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationGetting started with your DGH module:
Getting started with your DGH module: This document contains step-by-step instructions to quickly connect and communicate with your new DGH modules. For most applications, new modules require a one-time
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationTT-2-PE-M-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-2-PE-M-24DC Order No.: 2920641 Modular terminal block with two-stage surge protection for one operated floating double conductor, disconnect knife on both signal paths,
More informationISE 021 S-DIAS Interface Module RS232 / RS485
ISE 021 S-DIAS Interface Module RS232 / RS485 Date of creation: 23.04.2014 Version date: 31.01.2018 Article number: 20-101-021-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321
More informationCopyright Extract from Conditions of Sale Safety Warning
KD420 User Manual Copyright 2004-2013 KK Systems Ltd. No reproduction of any part of this document, in any form, is allowed without prior written permission from KKSystems Ltd. All other copyrights and
More informationIndustrial Media Converters
Wireless AP Industrial s Introduction & Features Fiber s Ethernet s Serial s s Distance Extension With Higher Immunity Introduction The media converters have incorporated SUNIX advanced technologies such
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationEasySYNC Ltd. USB to Serial Converters Manual
EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-08-23 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationSafety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty
NA-4020/4021 RS-485 or RS-232 network adaptors ioogik 4000 Modbus RS-485 NA-4020 SYS TxD RxD I/O Field Power CH0 24V 0V SG SG System Power (0 VDC) System Power (24 VDC) Shielding Ground Non-isolation Switching
More informationOMX-CI-RS232 Control Interface
Control Interface 970 Rev. B 0.0. Description Integrates GRAFIK 000TM, GRAFIK 000, GRAFIK 7000TM, Softswitch8, and LCP8 systems with a touchscreen or other digital equipment that supports RS communication.
More informationicex-cmtm General specs and Installation guide
icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB
More informationPSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems
Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch
More informationMegaAVR-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX
MegaAVR-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN 46268 (317) 471-1577 (317) 471-1580 FAX http://www.prllc.com GENERAL The MegaAVR-Development board is designed for
More informationVL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.
A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationCDN502 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER
More informationInstallation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter
Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter Introduction The USB to Octal Serial Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your
More informationInstalling the Panel. Installing the Panel
7 In this section you will be given all of the information you need to install the panel. Before actually installing the OP- panel, it may be helpful to examine the specifications and make sure that the
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationABB Drives. User s Manual Modbus Adapter Module FMBA-01
ABB Drives User s Manual Modbus Adapter Module FMBA-01 Modbus Adapter Module FMBA-01 User s Manual 3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 2005 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationTT-2-PE- 24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-2-PE- 24DC Order No.: 2838186 Modular terminal block with three-stage surge protection for a floating double conductor, separate ground connection, nominal voltage: 24
More informationL-MBUS20/L-MBUS80. User Manual. M-Bus Level Converter. LOYTEC electronics GmbH
L-MBUS20/L-MBUS80 M-Bus Level Converter User Manual Contact LOYTEC Blumengasse 35 A-1170 Vienna AUSTRIA/EUROPE support@loytec.com http://www.loytec.com Document 88077901 LOYTEC MAKES AND YOU RECEIVE NO
More informationCDN503 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER
More informationEA500. Installation Instructions Transponder
EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the
More informationSmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic
MAN0842-02 DIM610 PAGE 1 of 6 SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic 1 SPECIFICATIONS Number of Channels Input Ranges DIM610 12 PLC Update Rate 12/24 VDC Terminal Type DIM610
More informationDeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.
MAN0463-04 10 NOV 2006 PAGE 1 DeviceNet Master (Scanner) HE800 / HE-* DeviceNet Communications * HE- denotes plastic case. This datasheet also covers products starting with IC300. This product has a detailed
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More information4: Installing and Wiring System Components
Chapter 4 4: Installing and Wiring System Components Introduction This chapter shows you how to install SNAP PAC System components and connect them to field devices. This chapter includes basic information;
More informationTRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4
TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More informationVorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual
Vorne Industries Model 77/232 Serial Input Numeric 3" Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 Page 2 Model 77/232 Serial Input Numeric 3"
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationNPort 5100 Series Quick Installation Guide
NPort 5100 Series Quick Installation Guide Edition 4.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationRTU560 Connections and Settings DIN Rail RTU 560CIG10
Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail
More information485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
485DRCI Industrial RS-232 to RS-422/485 Converter p/n 7207r5 485DRCI-2212ds page 1/5 Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus
More informationICF-1150 Series Quick Installation Guide
ICF-1150 Series Quick Installation Guide Second Edition, March 2012 2012 Moxa Inc. All rights reserved. P/N: 1802011500011 Overview Introduction The ICF-1150 series fiber converters are equipped with a
More informationC-DIAS Serial Interface CSI 021
C-DIAS SERIAL INTERFACE CSI 021 C-DIAS Serial Interface CSI 021 The CSI 021 makes it possible to communicate via 2 independent UART's. 2 x RS232/485/422 outputs are available. These outputs are switchable
More informationMGate 5111 Quick Installation Guide
MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationVL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features
A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.
More informationGT- IRDM-9603 Product description Rev. 2 17/06/2014
GT- IRDM-9603 Product description Rev. 2 17/06/2014 1 1. Overview The GT- IRDM- 9603 is a complete Satellite Terminal solution for Satellite applications. Based on IRIDIUM 9603 module. 2. Hardware Interface
More informationCard Descriptions and Wiring Manual. Load Computer 1010 CJ
Card Descriptions and Wiring Manual Load Computer CJ Table of Contents CHAPTER 1 Card Descriptions and Terminal Layouts 1.1 CPU Card - S10CPU-xxx-I3..................................... 1-2 1.1.1 Card
More informationPCI Express 4-Port Industrial Serial I/O Cards
PCI Express 4-Port Industrial Serial I/O Cards The PCIe-400i and PCIe-400i-SI PCI Express 4-port industrial serial I/O cards are plug & play high-speed serial I/O expansion cards for the PCI Express bus.
More informationElectronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features
Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter
More informationMOXA TCC-120/120I User s Guide
MOXA TCC-120/120I User s Guide Seventh Edition, May 2006 www.moxa.com/product Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide:
More informationTRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual
TRP-C08S USB to 1 RS232 and 1 RS422/485 Isolated Converter User s Manual Printed Sep. 2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More informationUSER MANUAL FOR FIOA-0402-U-16
USER MANUAL FOR FIOA-0402-U-16 COPYRIGHT NOTICE This manual is a publication of Renu Electronics Pvt. Ltd. and is provided for use by its customers only. The contents of the manual are copyrighted by Renu
More information