Power Factor Correction Power Quality Solutions

Size: px
Start display at page:

Download "Power Factor Correction Power Quality Solutions"

Transcription

1 EPCOS Product Brief 2018 Power Factor Correction Power Quality Solutions PQS key components from EPCOS cover the entire range of products needed for successful power factor correction and harmonic filtering. All parts are carefully matched to each other. With this unique port folio, EPCOS is more than a sup plier of products: Power Quality Solu tions is the strategy that has been developed to fulfill the demand of the market to offer solutions rather than single components. This product brief gives an overview of all PQS products for power factor correction and harmonic filtering. For detailed information, please refer to the PFC Product Profile and data sheets, available in the Internet at or contact our local sales office. PQS key components PFC capacitors PhaseCap Energy/Premium/ Compact/ HD, DeltaCap, PhiCap, PoleCap Power factor controllers and measuring devices BR604, BR6000, BR7000, BR7000-I MMI6000, MMI7000, MMI8003 Grid analysis tool MC Capacitor contactors J230/J110 Thyristor modules for dynamic PFC TSM-series Active harmonic filter PQSine S Series Static var generator PQvar Reactors Antiresonance harmonic filter Discharge reactor Accessories

2 Capacitors Series PhaseCap Energy PhaseCap Premium PhaseCap Compact PhaseCap HD Two versions of power Premium power Compact power High-density power capacitors for low-voltage capacitors for low-voltage capacitors for low-voltage capacitors for low-voltage power factor correction power factor correction power factor correction power factor correction Technology MKK MKK MKK MKK Inrush current High pulse current High pulse current High pulse current High pulse current withstand capability withstand capability withstand capability withstand capability up to 500 I R depending up to 300 I R up to 400 I R up to 300 I R on the type; best in class Discharge resistor/ Ceramic discharge Ceramic discharge Ceramic discharge External discharge module resistor pre-mounted resistor pre-mounted resistor pre-mounted; module pre-mounted up to 525 V AC; up to 660 V AC; external discharge external discharge external discharge module for types 690 V module 600 V AC module 690 V AC Safety system B25674: triple Triple: Dual: Triple: B25675: dual Self healing Self healing Self healing Overpressure Overpressure Overpressure disconnector disconnector disconnector Dry technology Dry technology Impregnation B25674: gas filled, dry type Inert gas, dry, non-pcb Semi dry biodegradable Inert gas, dry, non-pcb B25675: soft resin resin, non-pcb Rated voltage V R V AC V AC V AC V AC Power Q R 5 33 kvar 5 33 kvar kvar kvar Rated frequency f R 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Winding Stacked Concentric Concentric Stacked (S-types stacked) Mounting position Upright/horizontal Upright/horizontal Upright/horizontal 1) Upright B25674* B25667C* B25673A* B25669* B25675* B25673S* Applications Automatic PFC Automatic PFC Automatic PFC Automatic PFC equipment, equipment equipment equipment capacitor banks Individual fixed PFC Individual fixed PFC Individual fixed PFC Individual fixed PFC Fixed PFC Fixed PFC Fixed PFC (e.g. motors, Tuned and detuned Tuned and detuned Detuned capacitor banks transformers, lighting) capacitor banks capacitor banks Group fixed PFC 690 and 800 V AC series 690 to 1000 V AC series Tuned and detuned for usage in harsh for usage in harsh capacitor banks application conditions, application conditions, Dynamic PFC e. g. industrial e. g. industrial applications with heavy applications with heavy harmonic loads harmonic loads 1) PhaseCap Compact S-types and DeltaCap: when mounting in horizontal position, additional mechanical support is recommended to prevent breaking of mounting bolt in case of mechanical shock or vibrations. This support should be placed at short distance below the bead at the top end of the capacitor. 2 EPCOS AG 2018

3 Capacitors Series DeltaCap PhiCap PoleCap Power capacitors for Power capacitors for Power capacitors for outdoor low-voltage power factor correction low-voltage power factor correction applications or harsh in industrial applications environmental conditions Technology MKD MKP MKP/MKK Inrush current High pulse current withstand High pulse current withstand High pulse current withstand capability up to 200 I R capability up to 200 I R capability up to 200 I R Discharge resistor/ Discharge module included Ceramic discharge resistor Integrated discharge resistor module in delivery, integrated in pre-mounted for B32344E series; terminal for B32304A****A***-series discharge resistors included in delivery for other series Safety system Dual: Dual: Triple: Self healing Self healing Self healing Overpressure disconnector Overpressure disconnector Overpressure disconnector Dry technology Impregnation Semi-dry biodegradable soft resin, Semi-dry biodegradable soft resin, Inert gas, non-pcb non-pcb non-pcb Rated voltage V R V AC V AC V AC Power Q R kvar kvar kvar Rated frequency f R 50/60 Hz 50/60 Hz 50/60 Hz Winding Stacked Stacked MKP: stacked MKK: concentric Mounting position Upright/horizontal 1) Upright/horizontal 1) Upright/horizontal B32300C*/B32303* series: B32340C* series: B25671A* Single-phase/three-phase, Single-phase, fast-on terminals fast-on terminals B32343C* series: B32301C*/B32304* series: Three-phase, fast-on terminals Single-phase/three-phase, B32344E* series: screw terminals Three-phase, optimized capacitor safety terminals Applications Automatic capacitor banks Fixed PFC applications, e. g. motor compensation AC power electronics Tuned and detuned PFC systems Approvals: VDE-approval Automatic capacitor banks Fixed PFC Detuned PFC systems Pole mounted PFC, i.e. outdoor applications Fixed PFC inside or outside a cabinet in surroundings with high dust or moisture concentrations Automatic PFC systems to reduce labor costs 1) PhaseCap Compact S-types, DeltaCap and PhiCap: when mounting in horizontal position, additional mechanical support is recommended to prevent breaking of mounting bolt in case of mechanical shock or vibrations. This support should be placed at short distance below the bead at the top end of the capacitor. EPCOS AG

4 Accessories Accessories 1) Protection class IP20 Plastic Protective Terminal Cover Modules for Capacitor Series Protection class IP54 PhaseCap Premium PhaseCap Compact (n/a for Ø 100 mm) PhaseCap Capacitor d x h 116 x 164 mm: B44066K0135A x 200 mm: B44066K0160A x 200 mm: B44066K0210A000 PhiCap Capacitor Ø 53 mm: B44066K0530A000 1) 63.5 mm: B44066K0635A000 1) 75 mm: B44066K0795A mm: B44066K0895A000 Ceramic Discharge Resistors Available on request for PhaseCap Premium, PhaseCap Compact, PhaseCap HD, PhiCap B32344 series. On request 4 EPCOS AG 2018

5 Key Components Series Power Factor Controllers Power Factor Controllers BR604 and BR6000 BR7000 and BR7000-T Large and multifunctional display (2x 16 characters, backlight for BR6000 series) BR6000-HD with OLED display Menu driven handling (plain language) Self-optimizing control capability Recall function of recorded values Automatic initialization possible for BR6000 Supply voltage: BR604: 230 V AC, 50/60 Hz BR6000: V AC, 50/60 Hz Measuring voltage: BR604: = supply voltage 230 V AC BR6000: V AC (L-N) or (L-L) Sensitivity: 50 ma/10 ma Measuring current BR6000: X:5 A / X:1 A Versions BR6000-HD6 and BR6000-HD12 with OLED display Three-phase measuring Three-phase display of numerous parameters as real value and in % Controlling three-phase, single-phase, mixed mode 2 isolated interfaces Illuminated graphic display, 128 x 64 dots, 8 lines Menu driven handling (plain language) HELP-button for interactive help text BR7000 for conventional PFC systems BR7000-T for dynamic PFC systems Supply voltage: V AC, ±15%, 50/60 Hz Measuring voltage: V AC (L-N); V AC (L-L) Measuring current: 3 X:5 A / X:1 A, selectable Operating ambient temperature: C BR7000: 15 relay outputs 3 additional alarm/message relays 2 independent interfaces BR7000-T: 15 transistor outputs 3 additional alarm/message relays 2 independent interfaces Evaluation software BR7000-SOFT incl. in the delivery Version BR7000-HD with OLED display BR604 (4 steps) BR6000-R6 (6 steps) BR6000-R12 (12 steps) BR6000-HD6 BR6000-HD12 BR6000-T6 (6 steps for dynamic PFC) B44066R6004E230 B44066R6006E230 B44066R6012E230 B44066R6506E230 B44066R6512E230 B44066R6106E230 BR7000 BR7000-HD BR7000-T B44066R7415E230 B44066R7515E230 B44066R7615E230 PC software BR7000-SOFT see page 6. EPCOS AG

6 Key Components Series Power Factor Controllers Power Factor Controllers BR7000-I and BR7000-I/S485 BR7000-I-TH and BR7000-I-TH/S485 Single-phase measuring Illuminated graphic display, 128 x 64 dots, 8 lines Menu driven handling (plain language) HELP-button for interactive help text BR7000-I standard version BR7000-I/S485 with interface RS485 Measuring device mode for simultaneous display of 3 parameters (large display also) 3-digit display of the power factor (cos f) / switchable display as tan f Display of values as bargraph-diagram possible Single-phase measuring Illuminated graphic display, 128 x 64 dots, 8 lines Menu driven handling (plain language) HELP-button for interactive help text Suitable for dynamic and mixed compensation Direct triggering of up to 32 thyristor switches series TSM-LC-S (version S485) at the bus Measuring of important grid parameters Measuring of distortion factor THD-V/THD-I Display of harmonics up to 33 rd Display of values as bargraph-diagram possible Supply Supply voltage: V AC, ±15%, 50/60 Hz Measuring voltage: V AC (L-N); V AC (L-L) Measuring current: X:5 A / X:1 A, selectable Operating ambient temperature: C 12 relay outputs for capacitor 1 relay output (message/alarm/fan) Standard system interface (e.g. for firmware update) BR7000-I/S485: Additional external input Additional message relay Serial interface RS485 Evaluation software BR7000-SOFT incl. in the delivery Supply voltage: V AC ±15%, 50/60 Hz Measuring voltage: V AC (L-N) V AC (L-L) Measuring current: X:5 A / X:1 A, selectable 12 relay outputs 12 transistor outputs 1 relay output (message/alarm/fan) Standard system interface (e.g. for firmware update) BR7000-I-TH/S485: Additional external input Additional message relay Serial interface RS485 Evaluation software BR7000-SOFT incl. in the delivery BR7000-I B44066R7012E230 BR7000-I-TH B44066R7412E230 BR7000-I/S485 B44066R7112E230 BR7000-I-TH/S485 B44066R7612E230 PC software BR7000-SOFT Connection to RS485 of BR7000, BR7000-I/S485 and BR7000-I-TH/S485 Administration of several PF controllers possible Comfortable analysis of recorded values Direct connection to USB port of a PC via USB-adapter Included in the delivery of BR7000, BR7000-I/S485 and BR7000-I-TH/S485 6 EPCOS AG 2018

7 Key Components Series Multi Measuring Interface MMI6000 Single-phase measuring of V, I, P, Q, S, cos f, f, W, T (read out via RS485) Coupling with PF controller BR7000, BR7000-I/S485 and BR7000-I-TH/S485 via interface for determination of real capacitor current Capacitor protection by step switch-off at current limit Fast trigger for dynamic PFC Independent switching of a single capacitor step Stand-alone measuring device with interface for read-out Panel mounting instrument Recording of maximum values Supply voltage: 230 V AC Measuring voltage: 230 V AC ±15% Measuring current: X:5 A / X:1 A Rated frequency f R: 50/60 Hz Power consumption: <4 VA Sensitivity: 40 ma LCD display 2 x 16 characters; alphanumeric MMI6000-R (version with relay output): B44066M6000E230 MMI6000-T (version with optocoupler output): B44066M6100E230 Multi Measuring Interface MMI7000 (V4) Three-phase measuring and display of numerous parameters: V, I, P, Q, S, cos f, f, W, T, THD-V, THD-I Display of harmonics as bar chart: harmonic of voltage up to 51 st and harmonic of current up to 51 st Integrated slot for SD memory card 2 independent interfaces (RS485) 4 relay outputs (free programmable) Oscilloscope mode: for graphic display of a complete oscillation incl. harmonics Display editor: for free programming of display for measured values Scan mode: for rotating display of selected values Display and recording of minimum and maximum values with time stamp Panel mounting instrument Graphical menu (DE/E/ES/RU/TR) Integrated help function Display of date and time Supply voltage: V AC ±10% Measuring voltage (3-phase): V AC (L-N) V AC (L-L) Measuring current: X:5 A / X:1 A Rated frequency f R: 50/60 Hz Power consumption: <5 VA Sensitivity: 50 ma/10 ma Illuminated full graphic LCD display, 128 x 64 dots B44066M7500E230 EPCOS AG

8 Key Components Series Multi Measuring Interface MMI8003 Three-phase grid measuring device in panels, e. g. feed-ins (V, I, P, Q, S, cos f, f, W, T, THD-V, THD-I) Measuring of power and harmonics For integration into existing networks via interface RS485 (MODBUS-RTU) Compatible with software MMI-energy for storage, display and evaluation of power and energy data Voltage harmonics up to 39 th order Current harmonics up to 39 th order Additional internal 24-hrs-ring buffer for the 15-min active energy values Internal storage for cumulated energy values Ring buffer for daily meter reading active power System clock for time stamp System interface RS485 (MODBUS-RTU) for processing of measured values Grid Analysis Tool MC Measuring, display and storage of numerous parameters Illuminated full graphic display, 128 x 64 dots Comfortable programming of recording interval Display and internal storage of max. values with time stamp Display of date and time Large number of display options Fast and easy evaluation of measured values, with PC software included in the delivery Automatic calculation of required kvar Recommendation for design of customized PFC system Supply voltage: 24 V DC (external via terminal) Measuring voltage: V AC (L-N), 50/60 Hz (10 80 Hz) V AC (L-L), 50/60 Hz (10 80 Hz) Measuring current (3-phase): 3 X:5 A / X:1 A, selectable Power consumption: <5 A Sensivity: 50 ma/10 ma RS485 system interface B44066M8003E024 Supply voltage (auxiliary voltage): V AC Measuring voltage (3-phase): V AC (L-N) V AC (L-L) Power consumption: <5 A Large number of accessories included: 3 safety measuring cables 1 safety measuring line 4 safety dolphin clips Windows-based software on CD-ROM 1 memory SD-Card 1 power lead B44066M7777E230 for flexible current clamps (not included in the delivery, but mandatory for operation): please refer to page EPCOS AG 2018

9 Key Components Series Capacitor Contactors Thyristor Modules for J230/J110 Dynamic PFC With pre-charge resistors Excellent damping of inrush current Soft switching of capacitors to increase the life expectancy of PFC systems, contactors and capacitors Reduced ohmic losses High safety standards Reduction of voltage sags and transients Easy installation: usage similar to a contactor Ultra-short reaction time, almost no inrush current Switching time: approx. 5 ms Permanent self controlling of various parameters: Voltage Phase sequence Capacitor output Display of: Operation Faults Activation Maintenance-free Long service life No switching noise TSM-LC-I for single-phase Voltage: V Output: kvar Auxiliary contacts: included (normally open) Mounting: integrated DIN-rail Approval: cul, CCC Voltage range: TSM-LC-I: V TSM-LC*: V TSM-LC-S: V TSM-LC-N480: V TSM-LC-N690: V Output range: TSM-LC-I: kvar, depending on voltage TSM-LC: 10, 25, 50, 100, 200 kvar, depending on the voltage J230 series B44066S****J230 TSM-LC-I: B44066T1022E520 J110 series B44066S****J110 TSM-LC*: B44066T****E402 TSM-LC-N1: B44066T3850E402 TSM-LC-S: B44066T1050E402 TSM-LC-N480: B44066T3850T408 TSM-LC-N690: B44066T3050E690 EPCOS AG

10 Accessories Accessories Data Logger DataLOG SD USB to RS485 Converter RJ45 Adapter Touch Panel VIP-3-TP PF controller PF controller PF controller PF controller BR7000, BR7000-I/S485 BR7000, BR7000-I/S485 BR7000, BR7000-I/S485 BR7000-I/S485 and BR7000-I-TH/S485 and BR7000-I-TH/S485 and BR7000-I-TH/S485 Multi Measuring Interface MMI6000/MMI7000 Usage for PF-controllers, BR7000, BR7000-I/S485 and BR7000-I-TH/S485 Recording of all grid parameters as well as of all relevant parameters of a compensation system, including switching sequences, switching-on time of all steps and temperature Direct connection to the controller interface via Ethernet cable is possible; 0.5 m cable is included Recording time up to several weeks Ready to use with a plastic casing Dimensions 66 x 28 x 66 mm Recording of measured values on SD-card (included) Evaluation of values with Windows based software, included in the delivery For connection of BR7000, BR7000-I/S485 and BR7000-I-TH/S485 with interface RS485 to PC with USB-interface Connection of several devices at RS485 possible For usage of software BR7000-SOFT on PC 3 versions available: Connection to the interface terminals of BR7000, BR7000-I/S485 and BR7000-I-TH/S485, MMI6000 or MMI7000 via LAN cable Simple connection of several devices via the RS485 bus, for example: Connection of several BR7000, BR7000-I/S485 or MMI7000 to a PC with BR7000-SOFT software Interconnection of several MMI6000/MMI7000 Suitable for: 1x RJ45 for BR7000, BR7000-I/S485, BR7000-I-TH/S485, MMI7000 Suitable for: 2x RJ45 for BR7000, BR7000-I/S485, BR7000-I-TH/S485, MMI7000 Suitable for: 2x RJ45 for MMI6000 Comfortable control device for intelligent coupling of 3 compensation systems. Enables operation of compensation systems in parallel for three coupled feeding transformers without any retroactivity. The control device VIP-3-TP realizes the coupling with PF-controllers BR7000-I/S485 and at the same time offers a comfortable visualization of the measuring values, switching states and of the actual system state. All possibilities of coupling are supported: Coupling with 2 coupling switches Ring coupling (3 coupling switches) Coupling via separate coupling bus bars (3 coupling switches) B44066R1311E230 B44066R3333E230 1x RJ45 for BR7000, B44066R1703E230 BR7000-I/S485, BR7000-I-TH/S485, MMI7000: B44066R1611E230 2x RJ45 for BR7000, BR7000-I-TH/S485, MMI7000: B44066R1711E230 2x RJ45 for MMI6000: B44066R1811E EPCOS AG 2018

11 Accessories Accessories UCM-5, MMI-energy EW-22 BD-xxx ESP-24 Flexible current clamps PF controller Thyristor modules Grid analyzing tool BR6000/BR7000 TSM series MC Multi Measuring Interface MMI6000/MMI7000/MMI8003 Recording and evaluation of counter values for processing (via RS485 interface) to PF controllerbr6000/br7000. Bus compatible S0-impulse module for software MMI-energy and BR6000/BR7000 for conversion of counter impulses (Q+, Q, P+, P, synchronic) on RS485 (MODBUS-RTU protocol) Accessory for the processing of counter values in the PFcontroller (controlling of reactive power related to counter impulses instead of current transformer) Allows processing of counter values via Windows-software MMI-energy (included in the delivery): cost centre management, visualization and evaluation Cross-linking of up to 32 devices (UCM-5, MMI6000, MMI7000) at MODBUS Evaluation software MMI-energy for PC (Windows-compatible, included in the delivery) Storage, display and evaluation of power and energy data on PC Single user and network solution available Graphical and numerical cost centre evaluation Supports UCM-5, MMI6000, MMI7000, MMI8003, BR6000, BR7000 at one bus (up to max. 32 devices possible) Zoom function, print function Parameterization of the device Discharge resistor block EW-22 Discharge resistor for all types of TSM-LC to achieve fast discharging. At least one piece per step required. Current limitation reactor BD-xxx (not suitable for TSM-HV) Protection of thyristor modules in PFC systems without reactor TSM-LC-I: 1x BD-50* ) TSM-LC10: 2x BD-50* ) or 2x BD-100 TSM-LC100: 2x BD-200 TSM-LC-N: 2x BD-100 TSM-LC-S : 2x BD-100 Feed-in module ESP-24 Required for voltage supply of TSM-LC-S (one per 10 switches) for feed-in of power pack 24 V DC 1x Flexible current clamp Mini-Flex MMI x Flexible current clamps Mini-Flex MMI * ) BD-50 production only after ordering UCM-5: B44066R1411E230 Discharge resistor block EW-22: B44066T0022E400 Current limitation reactor BD-xxx: B44066T0***E400 Feed-in module ESP24: B44066T0002E400 1x Flexible current clamp: B44066M1301E230 3x Flexible current clamps: B44066M1303E230 EPCOS AG

12 Key Components Series Reactors Reactors Antiresonance Harmonic Filter Discharge Reactor High harmonic loading capability, very low losses High linearity to avoid choke tilt, low noise emission Fast discharge for fast reconnection of capacitors Reduced losses Shockproof case for DIN-rail mounting Voltage: 400, 440, 690 V Frequency: 50 or 60 Hz Output: kvar Harmonics (duty cycle = 100%): V 3 = 0.5% V R V 5 = 6.0% V R V 7 = 5.0% V R V 11 = 3.5% V R V 13 = 3.0% V R Effective current: I rms = ß (I 1 2+l l 13 2) Fundamental current: I 1 = 1.06 I R (50 Hz or 60 Hz current of capacitor) Temperature protection: microswitch (NC) Detuning factor: 5.67%, 7%, 14% Voltage: V Frequency: 50/60 Hz Discharge time (t): 230 V: up to 25 kvar <10 s up to 50 kvar <20 s up to 100 kvar <40 s V: up to 25 kvar <5 s up to 50 kvar <10 s up to 100 kvar <20 s V: up to 25 kvar <3 s up to 50 kvar <6 s up to 100 kvar <12 s B44066D* B44066E9900L EPCOS AG 2018

13 Power Quality Solutions: Key Components, Systems and Modules Series Active Harmonic Filter, Systems and Modules PQSine S Series Harmonic compensation up to 50 th harmonic (individually selectable) Ultra-fast reactive power compensation (inductive and capacitive) Load balancing between phases and unloaded neutral wire Compact design, 3 level topology with very low losses Modular system extendable Grid resonance detection Digital control of FFT algorithm, intelligent FFT algorithm, instantaneous reactive algorithm User-friendly menu operation High performance and reliability Insensitive to network conditions Rated voltage: 380 V ( V); 480 V ( V); 690 V ( V) Mains frequency: Hz Filter current: 25, 35, 50, 60, 75, 90, 100, 150 A Neutral filtering capability 3 times the rated filter current (in case of 4 wire device) Harmonic current compensation range: 2 nd to 50 th harmonic order, or specified harmonics 0 to110% Rate of harmonic reduction: > 97% 1) Typical power losses: < 3% (depending of the load) Target power factor: Adjustable from 1 to 1 Switching / Control frequency: 20 khz/20 khz Reaction time: Approx. 20 µs in case of instantaneous reactive algorithm Overall response time: < 5 ms in case of instantaneous reactive algorithm Display: All systems include a TFT color control / display unit (touch screen) Communication ports: RS485 and network port (RJ45) Communication protocols: Modbus (RTU), TCP/IP(Ethernet) Fault alarm: Available, max. 500 alarm records Operating temperature: 10 to +40 C without derating, other temperature ranges upon request Protection class: IP 20 according to IEC 529 (customizable), optional IP30, IP42, IP54 upon request B44066F****S*** Applications Fast current harmonics and reactive power suppression e.g. for: Data centers UPS systems Green power generation (e.g. photovoltaics and wind turbines) Sensitive equipment manufacturing (e.g. silicon waferproduction, semiconductor production) Industrial production machines Electrical welding systems Plastic industry machinery (extruders, injection molders) Office buildings and shopping centers (3 rd and triple harmonic cancellation and neutral conductor unloading) 1) For typical harmonic distortions EPCOS AG

14 Power Quality Solutions: Key Components, Systems and Modules Series PQvar static var generators (SVGs) New active approach to reactive power factor correction and load balancing Active compensation device that needs no conventional PFC capacitors or reactors Improves system power factor to a target value of > 0.9 without over- or under-compensation Extremely rapid dynamic compensation reaction time of < 50 µs and a fast response time of < 15 ms Balance loads between phases Can be installed together with existing capacitor banks Rated voltage: 400 V; % (other rated voltages on request) Mains frequency: 50/60 Hz (range: Hz) Parallel operation: Unlimited Reaction / response time: < 50 µs / < 15 ms Overall efficiency: > 97% Power grid structure: 3P3W / 3P4W Current transformers: 150/ /5 Circuit topology: 3-level, with very low losses Single-module compensation capacity: 30, 50, 100, 200 kvar Target power factor: Adjustable from 1 +1 Cabinet mounting: Floor-mounted, wall-mounted Communication ports: RS485, CAN, and network port Communication protocols: Modbus and PMBus Noise level: < 65 db (depending on the model) Protection functions: Over-voltage, under-voltage, short-circuit, inverter bridge inverse, overcompensation Operating temperature: C, other temperature ranges upon request Protection class: IP20, optional IP30, IP42, IP54 upon request B44066F****V*** Applications Rapid power factor correction and load balancing e.g. at industrial sites and in commercial buildings Important information: Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products. We expressly point out that these statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. It is incumbent on the customer to check and decide whether a product is suitable for use in a particular application. This publication is only a brief product survey which may be changed from time to time. Our products are described in detail in our data sheets. The Important notes ( and the product-specific Cautions and warnings must be observed. All relevant information is available through our sales offices. 14 EPCOS AG 2018

15

16 EPCOS AG A TDK Group Company Edition 2018 Ordering No. EPC: Printed in Germany PB

Power Factor Correction Power Quality Solutions

Power Factor Correction Power Quality Solutions EPCOS Product Brief 2015 Power Factor Correction Power Quality Solutions PQS key components from EPCOS cover the entire range of products needed for successful power factor correction. All parts are carefully

More information

Power Factor Correction

Power Factor Correction Product Brief 2009 Power Factor Correction P o w e r Q u a l i t y S o l u t i o n s PQS key components from EPCOS cover the entire range of products needed for successful power factor correction. All

More information

Power Factor Correction

Power Factor Correction Product Brief 2011 Power Factor Correction PhaseCap Compact for Power Quality Solutions The PhaseCap Compact series is based on the EPCOS MKKtechnology, which is known for many years from the successful

More information

PF Controllers BR6000 Series

PF Controllers BR6000 Series PF Controllers BR6000 Series Intelligent User-friendly Cost-effective Version 5.0 General Controllers for PFC are of major importance in the PFC system. They measure the actual power factor and connect

More information

B44066T3050E402 B44066T3850E

B44066T3050E402 B44066T3850E Thyristor Module Series/Type: The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal Deadline Last Orders Last Shipments B44066T3850E402

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type: Ordering code: Date: January 2013 Version: 1 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type: Ordering code: Date: October 2016 Version: 5 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type: Ordering code: Date: March 2012 Version: 2 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color

More information

Film capacitors Power Factor Correction

Film capacitors Power Factor Correction Series/Type: Ordering code: Date: March 2009 Version: 1 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color

More information

Film capacitors Power Factor Correction

Film capacitors Power Factor Correction Series/Type: Ordering code: B44066T0200E690 Date: June 2012 Version: 6 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type: Ordering code: Date: Jan 2015 Version: 3 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color

More information

LSFC Power Factor Correction Systems

LSFC Power Factor Correction Systems LSFC Ready to connect, automatic in sheet steel cabinets for floor installation. Suitable for networks without harmonic distortion. Power Range: 100 to 00 kvar Modular construction in freestanding sheet

More information

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser 4 Target Max. Demand (MD) Load Shed Controller Up to 64 loads may be shed to

More information

Film capacitors Capacitors for Power Factor Correction

Film capacitors Capacitors for Power Factor Correction Multi-measuring interface for BR6000 controller Series/Type: Ordering code: Date: September 2007 Version: 1 Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines,

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006 PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

Rapidus Power Factor Controller

Rapidus Power Factor Controller Rapidus Power Factor Controller Moduler design No connector cables No fixing screws State of the art technology Easy mounting on panels connection to system Dynamic Capacitor Monitoring DCM is a supreme

More information

Power Factor Correction

Power Factor Correction For a better Power! Power Factor Correction Low Voltage GMKP Contactors Save energy and reduce Carbon Dioxide emission! FRANKE GMKP LTD. Http://www.frankegmkp.com Berlin,Frankfurt,Germany Tel: 0049 30200033043

More information

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values CT/VT Interface 560CVT10 The fault current is measured up to 20 times nominal current. Therefore the current inputs withstand 50 times nominal current for 1 s. The CT/VT interface is equipped with one

More information

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Energy Management Solutions

Energy Management Solutions Energy Management Solutions Power Generation and Transmission Facilities You can provide solution in your Power transmission project with Klea Energy Analyser and Systemon Software Shopping Malls and Chain

More information

Multi-Measuring-Interface MMI 6000

Multi-Measuring-Interface MMI 6000 Multi-Measuring-Interface MMI 6000 M M I - 6000 MMI 6000 Multi-Measuring Interface Program Enter Manual of operation V 8.0 E Version 8.0 / 01.12.2016 Contents Section 1 General remarks 3 Section 2 Technical

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt Smart Energy & Power Quality Solutions UMG 505 Power analysis, LON and I/O-Vielfalt UMG 505 UMG 505 Power analysis, LON and I/O-Vielfalt Power analysers of the UMG505 product family are mainly designed

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Film Capacitors Power Factor Correction Installation and maintenance instructions for PFC capacitors Series/Type: PoleCap capacitors Ordering code: B25671* Date: December 2009 Version: 2 Content of header

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY COMPREHENSIVE INSTRUMENT FOR MEASUREMENT AND CONTROL OF POWER SYSTEMS CENTRAX CU-SERIES CENTRAX CU3000 CENTRAX CU5000 PAGE 2 Comprehensive instrument for measurement

More information

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring UMG 96S PQM - Power Quality Monitoring The little field bus giant Universal flush-mounting measuring instruments of the UMG 96S product family are mainly designed for use in low and medium voltage distribution

More information

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus

More information

Three-Phase Power Quality Analyzer PowerPad Model 3945

Three-Phase Power Quality Analyzer PowerPad Model 3945 Three-Phase Power Quality Analyzer PowerPad Model 3945 Wouldn t it be nice if you could look inside your electrical system and see what s going on? Troubleshooting would be so much easier if you could

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight

More information

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management. RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels 20 Channel Branch Circuit Monitoring Device with RCM Interfaces / communication RS485 RTU Accuracy of measurement

More information

with Backlight Graphic LCD Screen

with Backlight Graphic LCD Screen with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of

More information

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument Smart Energy & Power Quality Solutions UMG 96S Universal flush-mounting measuring instrument UMG 96S UMG 96S Universal flushmounting measuring instrument Universal flush-mounting measuring instruments

More information

USER MANUAL 2012 V1.1

USER MANUAL 2012 V1.1 SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information

More information

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

Digital Multifunction Meters. Digital Multifunction Meters

Digital Multifunction Meters. Digital Multifunction Meters Digital Multifunction Meters Digital Multifunction Meters DIGITAL MULTIFUNCTIOL METERS SECTION INDEX 1. MFM 3410 3420 3430 3440 6100 & 2000 - Multifunctional Instrument Series 2. EM 3490, 3490SS, 3490DS

More information

CeraDiodes for ESD Protection

CeraDiodes for ESD Protection EPCOS Sample Kit 12 CeraDiodes for ESD Protection www.epcos.com What are CeraDiodes? CeraDiodes are multilayer semiconductor ceramic components for the ESD protection of data, audio and video lines, ICs

More information

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers

More information

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information Power and accuracy 0.2% or 0.5% class in power and active energy measurement Over 500 electric parameters display Both voltage and current harmonics spectrum graphics (to the 50 th ) Maximum and minimum

More information

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input. ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal

More information

DRTS 66 can test all the following relays

DRTS 66 can test all the following relays Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs

More information

Energy Management Modular Energy meters Type EM2-96

Energy Management Modular Energy meters Type EM2-96 Energy Management Modular Energy meters Type EM2-96 Product Description µp-based modular energy meter with a built-in configuration key-pad. The energies are both partial and total counted. The housing

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Ceramic Transient Voltage Suppressors

Ceramic Transient Voltage Suppressors EPCOS Sample Kit 2015 Ceramic Transient Voltage Suppressors CTVS Multilayer Varistors and CeraDiodes for Industrial Use www.epcos.com Protection against ESD and surge currents for industrial use Industrial

More information

Power factor correction (PFC) and harmonics filter

Power factor correction (PFC) and harmonics filter Power factor correction (PFC) and harmonics filter 08 Power factor correction (PFC) and harmonics filter Prophi power factor controller Optimised control for longer service life The universal capacitor

More information

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts The CT-APS.21 is an electronic timer from the CT-S range with OFF-delay. It provides 10 time ranges and a continuous rated control

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

EngyVolt RV12 and RV15

EngyVolt RV12 and RV15 Technical Information EngyVolt RV12 and RV15 Multifunctional electrical energy meters for top-hat rail installation or panel mounting Application For measuring voltage, frequency, current, power, as well

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet 2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges

More information

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar

More information

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

Three-Phase Power Quality Analyzer PowerPad Model 3945-B Three-Phase Power Quality Analyzer PowerPad Model 3945-B Display and record waveforms, transients, trend data and events simultaneously! Wouldn t it be nice if you could look inside your electrical system

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

Voltage Transducer UMT516 / MT516

Voltage Transducer UMT516 / MT516 Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating

More information

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal

More information

ISOMETER isoev425 with coupling device AGH420

ISOMETER isoev425 with coupling device AGH420 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device

More information

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG www.oem.co.uk Contents Shunts Page 3-4 Digital Meters with Bargraph Page 5-6 Large Displays Page 6-7 Power Analyzers, Synchronizing Units Page 8 Recorders Page

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. D R T S 6 6 THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. www.isatest.com DRTS 66 The new generation of advanced test equipments for relays,

More information

User manual Technical parameters

User manual Technical parameters User manual Technical parameters thyro System english Thyristor for reactive current compensation 2 KBR GmbH Subject to technical changes Contents Intended use... 4 Safety Notes... 6 Application range...

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring UMG 511 PQM - Power Quality Monitoring Class A power quality analyser according to IEC61000-4-30 The UMG 511 power quality analyser is particularly suitable for monitoring power quality according to standards

More information

Your technology partner Datakom, innovative products, affordable prices.

Your technology partner Datakom, innovative products, affordable prices. Your technology partner Datakom, innovative products, affordable prices. GENSET PRODUCTS Synchronization Units Multifunctional Units The D-700 is a comprehensive genset controller capable of all possible

More information

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision Power Sensors Ltd New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Edition 3 Energy Revenue Grade class 0.2/0.2s Accuracy Additional AC, DC, and

More information

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes System Freelance 800F AC 700F Module Description Data Sheet Central Processing Unit PM 783F Detailed data of the CPU (PM 783F) CPU Processor Program memory (Battery backed up) Internal memory Typical cycle

More information

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Distributed by Keor T UPS THREE-PHASE UPS from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES T THREE-PHASE UPS T has been designed with advanced technologies and the

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching Contactors Types K3-..A.. and K3-..K.. Ideal for Power Factor and Harmonic Filter Systems Features that matter Patented design with significant damping of inrush current Long life tested

More information

Y07/1-01(V1.0) Goodrive20 Series Vector Control Inverter

Y07/1-01(V1.0) Goodrive20 Series Vector Control Inverter Y07/1-01(V1.0) Goodrive20 Series Vector Control Inverter Goodrive20 Series Vector Control Inverter Introduction... 2 Features Introduction 3 Optimized structure design 3 Goodrive20 series inverters feature

More information

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment NTSA has developed the ultimate solution for protecting

More information

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges

More information

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New) XU1-E Earth fault voltage relay (August 1996) Manual XU1-E (Revision New) Woodward Manual XU1-E GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights BRANCH FEEDER MONITOR SATEC s is the second generation of Branch Feeder Monitor, providing energy management for multi-point power solutions. Ideal for both new and retrofit projects, the automatically

More information

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5% RDG (current/voltage) Universal utility meter and power

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact The CT-ERS.12 is an electronic timer from the CT-S range with ON-delay and 10 time ranges. All electronic timers from the CT-S

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Energy Revenue Grade class 0.2s Accuracy Additional AC, DC, and Environment Sensor Channels World

More information

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1 4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

Power Factor Controller BR604

Power Factor Controller BR604 Power Factor Controller BR604 Series/Type: BR604 Ordering code: Date: December 2006 Version: 2 Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines, headers

More information

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O U niversal Measuring Device Little Fieldbus Giant Modbus / Profibus Harmonics Memory Analogue outputs Digital I/O Modem Recorder Profibus Modbus PC I/O Universal Measuring Device Application Application

More information

Neon pr. ph/ ORP measurement. Applications. Description

Neon pr. ph/ ORP measurement. Applications. Description Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment

More information

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks General NEPSI's activar, Medium

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data

More information