1 VS520DZ Tech Sheet Balboa Instruments System PN System Model # VSP-VS520DZ-YCAH Software Version # 43 EPN # 2765 Base PCBA - PN PCB VS500Z - PN Rev D or E Base Panels VL801D (Serial Deluxe) PN VL802D PN Template used: 40600_P.pdf 01/07/2008.pdf 04/08/2008 Page 1
2 System Revision History System PN EPN Date Requested By Changes Made Balboa New system Balboa Update to 48A service YCAH Balboa Software update to v41, A5 ON Balboa Software revert to v Balboa Software update to v43 Page 2
3 Basic System Features and Functions Power Requirements System Outputs Setup 1 (As Manufactured) (Stereo) Optional Devices Additional Options K8 J2 W2 W3 A J2A U FUSE 8 3 J60 J22 J7 J8 J44 BALBOA INSTRUMENTS, INC. VS500Z P/N REV D 2-SPD EXT RLY EXT. RLY AUX. F SEN. A SEN. B VAC MADE IN U.S.A COPYRIGHT 2005 Page 3
4 G C Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Memory for your new DIP Switch Settings changes to take effect. If you do not reset Persistent Memory, your system may function improperly. To reset Persistent Memory: Power down by disconnecting power source from spa. Put a jumper across J43, covering both pins. (See illustration below) Power up by connecting power source to spa. Wait until is displayed on your panel. Power down again. Remove jumper from J43 (May also move to cover 1 pin only) Power up again. About Persistent Memory and Time of Day Retention: This system uses memory that doesn t require a battery to store a variety of settings. What we refer to as Persistent Memory stores the filter settings, the set temperature, and the heat mode. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. Power Up Display Sequence Upon power up, you should see the following on the display: Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, which should match the version of your system. For example, if these three numbers are, that is a VS511SZ at version 38. Displayed next is: (indicating the system is configured for a heater between 3 and 6 kw) or (indicating the system is configured for a heater effectively* between 1 and 3 kw). should appear for all VS models running at 240VAC. should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kw at 240VAC will function as a 1 kw heater at 120VAC.) will appear to signal the start of Priming Mode. At this point, the power up sequence is complete. Refer to the Reference Card for the VS or GS System model of your spa for information about how the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. J43 E.GND K6 F4 FUSE.3A 250V J23 K1 W1 SWITCHBANK T1A K3 K2 F2 W4 E.GND J50 J6 SWITCHBANK A F7 7/26 S1 TST FUSE 20A 250V W7 K8 K9 J43 J2 J46 J60 J22 J6 J7 J8 S1 TST EXT. AUX. F RLY SEN. A SEN. B J47 W2 W3 A J2A J U4 2 J20 F1 0 FUSE 3A 250V 8 3 BALBOA INSTRUMENTS, INC. 2-SPD J44 VS500Z EXT RLY P/N REV D VAC MADE IN U.S.A COPYRIGHT 2005 J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. J26 J90 J50 LINE BLK AC W1 K4 K1 VS100 P/N 22964_B MADE IN U.S.A PUMP T0.25A 250V Balboa J58 J23 F2 HEATER OZONE J29 WHT AC K3 J9 K2 SWITCHBANK A NEUTRAL J57 TST RST J6 J43 F4 S1 SWITCHBANK A TST RST J6 J43 J43 on VS100/GS100 Series Main Board Shown. F5, F3A 250V 3 2 J7 SEN. A J8 SEN. B 8 U4 J20 Page 4
5 Wiring Configuration and DIP Settings Setup 1 (As Manufactured) (Stereo) CLASS G FUSE 30A J66 J65 1 F5 WHT AC 5 6 J25 J63 J64 NEUTRAL WHITE BLK AC J61 J62 K6 J23 F4 FUSE.3A 250V 2-Spd P1 J74 W1 J73 PCBA Rev D & E only. Black jumper required. Do not remove. K1 J50 W10 W4 T1 Audio Visual Blower Ozone and Circ Pump must be same voltage. Do not remove Fuse F7 (20A) F7 FUSE 20A 250V J47 J29 7/26 W7 K9 K8 J46 Circ.Pump W2 W3 A Ozone J20 12V Light F1 0 FUSE 3A 250V K4 TORQUE RANGE FOR TB1: IN. LBS. HOT BLACK HOT RED TB1 K3 K2 J2 J2A VS5xxD mode U4 2 8 J32 J33 J34 J35 J43 00 J36 Balboa J37 RED AC HTR2 01 HTR1 F2 E.GND SWITCHBANK A J60 J22 J6 J7 J8 S1 TST EXT. RLY AUX. F SEN. A SEN. B J44 BALBOA INSTRUMENTS, INC. VS500Z P/N REV D VAC MADE IN U.S.A COPYRIGHT SPD EXT RLY kw Heater 240V (Approx. 120V) W1 R B W G 2-Spd P2 F30A 480V X-P332 PN P/N REV B J6 J7 WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) SSID # A1, Test Mode OFF A2, See Table 1 A3, N/A A5, 2-speed P1 Panel Button Assignments 1=Time 5=Light 2=Mode/Prog 6=Pump 1 3=Temp Up 7=Pump 2 4=Temp Down 8=Unused 8=7/26 A7, 7/26 Disabled Enabled A9, Non-Circ Mode A10, See Table 1 Panel Button Positions Page 5 VS51x/VS5xxS/VS5xxD Compatible J43 Memory Reset Wiring Color Key 120 Volt Connections 240 Volt Connections Black AC Jumpers 12 Volt Connections Relay Control Wires Board Connector Key 1 Typically Line voltage 2 Typically Line voltage for 2-speed pumps 3 Neutral (Common) 4 Ground Note flat sides in connector
6 DIP Switches and Jumpers Definitions SSID DIP Switch Key A1 Test Mode (normally OFF) A2+A10 Control amp draw requirements (See Table 1) A3 N/A (must be OFF) A4 Aux Freeze (must be OFF) A5+A9 Pump 1 speeds and Circ Modes: A5 A9 Circ Mode Pump 1 Speed OFF OFF Non-circ 2-speed ON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speed OFF ON 24 hours with 3 F shut-off 1-speed ON ON 24 hours with 3 F shut-off 2-speed A6 ON position: 50Hz operation OFF position: 60Hz operation A7 ON position: 7/26 equipment enabled OFF position: 7/26 equipment disabled A8 ON position: temperature is displayed in degrees Celsius OFF position: temperature is displayed in degrees Fahrenheit Base Model VS520DZ Table 1 # of Hi-Speed Pumps/Blower Before Heat Disabled A2 A10 OFF OFF 0 ON OFF 1 OFF ON 2 ON ON 3 Jumper Key 2 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for VS51xZ/VS5xxSZ/VS5xxDZ software. Jumper must be on Pins 2 and 3 for VS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this tech sheet. 1 Panel Button Positions Aux Panel Information Supports 2-button aux panel VX Supports 4-button aux panel 1=Time 2=Mode/Prog 3=Temp Up 4=Temp Down Panel Button Assignments 5=Light 6=Pump 1 7=Pump 2 8=7/26 (when A7 is ON) VX40D Page 6
7 W W Ozone Connections Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the required voltage. WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage is selected. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 120V ozone Ground (Green) conductor B G Balboa Ozone connector configuration for 240V 60Hz Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 240V ozone Ground (Green) conductor Flat sides of sockets as shown B G FUSE 20A 250V J46 J47 J29 K8 Circ.Pump G W B R W2 W3 A J20 12V Light F1 FUSE 3A 250V Line - Black conductor Use this slot for the leftover conductor Common - Red for 240V or White for 120V ozone (See W2 wire) Ground (Green) conductor W2 wire determines voltage 0 Page 7
8 Serial Deluxe Panel Configurations Time Warm Blower Light Mode/Prog Cool Jets 1 Jets 2 VL801D (Serial Deluxe) PN with Overlay PN Connects to Main Board terminal only* SETUP 1 Time Warm Blower Light Mode / Prog Cool Jets 1 Jets 2 VL802D PN with Overlay PN Connects to Main Board terminal only* * Panels with back-lighting (bulbs installed) should never be plugged into J2. Use only. If the backlight bulbs are removed, then both and J2 may be used. Page 8
VS510SZ Tech Sheet. Balboa Instruments. System PN System Model # VSP-VS510SZ-DCAH Software Version # 43 EPN # 2765
VS0SZ Tech Sheet Balboa Instruments System PN 437-02 System Model # VSP-VS0SZ-DCAH Software Version # 43 EPN # 27 Base PCBA - PN 4372-02 PCB VS00Z - PN 22972 Rev C or D Base Panels VL700S PN 38 VL70S (Serial
More informationVS515Z Tech Sheet. Balboa Instruments. System PN System Model # VSP-VS515Z-YCAH Software Version # 43 EPN # 2816
VS515Z Tech Sheet Balboa Instruments System PN 55476 System Model # VSP-VS515Z-YCAH Software Version # 43 EPN # 2816 Base PCBA - PN 55477 PCB VS500Z - PN 22972 Rev D Base Panels VL400 PN 55129 Template
More informationVS501Z Hot Sheet. Balboa Instruments. System PN System Model # VSP-VS501Z-CCAH Software Version # 43 EPN # 2720
VS50Z Hot Sheet Balboa Instruments System PN 54356-03 System Model # VSP-VS50Z-CCAH Software Version # 43 EPN # 2720 Base PCBA - PN 54357-03 PCB VS500Z - PN 22972 Rev C or D Base Panels VL40 (LCD Lite
More informationCS5100DV Tech Sheet. Cal Spas. System PN System Model # VSP-CS5100DV-BCAH Software Version # 46 EPN # 3288
CS5100DV Tech Sheet Cal Spas System PN 55736-01 System Model # VSP-CS5100DV-BCAH Software Version # 46 EPN # 3288 Base PCBA - PN 55737-01 PCB VS500DVH - PN 23928 Rev A Base Panels VL260 PN 54754-03 with
More informationCS6300DV Tech Sheet. Cal Spas. System PN System Model # VSP-CS6300DV-BCAH Software Version # 45 EPN # 3092
CS6300DV Tech Sheet Cal Spas System PN 55740 System Model # VSP-CS6300DV-BCAH Software Version # 45 EPN # 3092 Base PCBA - PN 5574 PCB VS500DVH - PN 23928 Rev A Base Panels Mini-dash PN 53850-06 with Overlay
More informationCS6200DV Tech Sheet. Cal Spas. System PN System Model # VS5-CS6200DV-BCAH Software Version # 45 EPN # 3091
CS6200DV Tech Sheet Cal Spas System PN 55738 System Model # VS5-CS6200DV-BCAH Software Version # 45 EPN # 309 Base PCBA - PN 55739 PCB VS500DVH - PN 23928 Rev A Base Panels Mini-dash PN 53850-06 with Overlay
More informationBalboa Water Group. System PN System Model # MM7-VS100-HCAK Software Version # 41 EPN # Base PCBA - PN PCB VS100 - PN Rev B
VS100 Tech Sheet Balboa Water Group System PN 54655 System Model # MM7-VS100-HCAK Software Version # 41 EPN # 3450 Base PCBA - PN 54656 PCB VS100 - PN 22964 Rev B Base Panels VL200 (Mini) PN 55123 VL240
More informationGS523DZ Tech Sheet. Balboa. System PN System Model # GS5-GS523DZ-RCA-3.0 Software Version # 43 EPN # 2808
S5DZ Tech Sheet System PN 576-0 System Model # S5-S5DZ-RCA-.0 Software Version # EPN # 808 Base PCBA - PN 55857-0 PCB S500Z - PN 05 Rev B Base Panels VL80D (Serial Deluxe) PN 5 VL80D PN 556 Template used:
More informationVS510SZ Hot Sheet. System Model # VSP-VS510SZ-DCAH Software Version # 36 EPN # Base PCBA - PN PCB VS500Z - PN Rev C or D
VS510SZ Hot Sheet System Model # VSP-VS510SZ-DAH Software Version # 36 EPN # 1801 Base PBA - PN 54372-01 PB VS500Z - PN 22972 Rev or D Base Panels Serial Standard PN 53189 Template used: 40600_E.pdf 07/05/2006.pdf
More informationVS501Z-4K Hot Sheet. System Model # VSP-VS501Z-CCAJ Software Version # 35 EPN # Base PCBA - PN PCB VS500Z - PN Rev C or D
VS501Z-4K Hot Sheet System Model # VSP-VS501Z-AJ Software Version # 35 EPN # 1801 Base PBA - PN 54357-01 PB VS500Z - PN 22972 Rev or D Base Panels Mini PN 52144 Lite Digital PN 54094 Lite Duplex PN 51676
More informationGL2001 Mach 3 Tech Sheet Balboa Instruments
GL2001 Mach 3 Tech Sheet Balboa Instruments System PN 53883-04 System Model # GL2-GL2001M3-RCA-3.0 Software Version # 32 EPN # 2833 Base PCBA PN 53975-04 PCB GL2000 PN 22898 Rev B, C, or D HEX File 10011932
More informationEL2000 Mach 3 Tech Sheet Balboa Instruments
EL2000 Mach 3 Tech Sheet alboa Instruments System PN 55065-04 System Model # E2P-EL2000M3-YCAH Software Version # 32 EPN # 2833 ase PCA PN 53834-05 PC EL2000 PN 22896 Rev HEX File 10011432 ase Panels ML900
More informationEL2000 Mach 3 Hot Sheet
EL2000 Mach 3 Hot Sheet System Model # E2P-EL2000M3-YCAH Software Version # 28 EPN # 2130 ase PCA - PN 53834-03 PC EL2000 PN 22896 Rev ase Panels ML900 PN 52654 ML700 PN 52649 ML400 PN 52684 Template used:
More informationSystem PN 53254_03 (Mach 2) Balboa Instruments
GL8000 Hot Sheet System PN 53254_03 (Mach 2) alboa Instruments System Model # GL8-GL8000-RCA-3.0K Universal AC Service Option ase PCA PN GL8000 53255-01 ase Panels ML700 PN 52649 ML900 PN 52654 The ML700
More informationBFBP21 Tech Sheet. Customer: Bullfrog Spas. Part Number: X1 825 Incoloy Custom Box Overlay Box Overlay Part Number 46091
BFBP21 Tech Sheet Customer: Bullfrog Spas Part Number: 56342-01-X1 825 Incoloy Custom Box Overlay Box Overlay Part Number 46091 UL System Model: BP21-BFBP21-AS Software Version ID: M100_225 V13.0 Software
More informationMS40E Tech Sheet. Customer: Master Spas. Part Number: kW 800 Incoloy Heater Custom Box Overlay Box Overlay Part Number N/A
MS40E Tech Sheet Customer: Master Spas Part Number: 56352-01 3kW 800 Incoloy Heater Custom Box Overlay Box Overlay Part Number N/A UL System Model: BP21-MS40E-RCA3.0K Software Version ID: M100_225 V9 Software
More informationBP21MS3B Tech Sheet. Customer: Balboa Water Group. Part Number: Incoloy 3kW Incoloy 3kW Titanium 3kW
BP21MS3B Tech Sheet Customer: Balboa Water Group Part Number: 56633 800 Incoloy 3kW 56634 825 Incoloy 3kW 56635 Titanium 3kW Custom Box Overlay Box Overlay Part Number N/A CE System Model: BP21-BP21MS3B-RCA3.0K
More informationBP21P4BC Tech Sheet. Customer: Balboa Water Group. Part Number: Incoloy 3kW Incoloy 3kW Titanium 3kW
BP21P4BC Tech Sheet Customer: Balboa Water Group Part Number: 56625 800 Incoloy 3kW 56626 825 Incoloy 3kW 56627 Titanium 3kW Custom Box Overlay Box Overlay Part Number N/A CE System Model: BP21-BP21P4BC-RCA3.0K
More informationBP6013G3 Tech Sheet Customer: Balboa Water Group Part Number:
BP6013G3 Tech Sheet Customer: Balboa Water Group Part Number: 56833 800 Incoloy 3kW 56834 Titanium 3kW Custom Box Overlay Box Overlay Part Number N/A CE System Model For 3.0kW: BP21-BP6013G3-RCA3.0K Software
More informationBP2100G1 Tech Sheet. Customer: Balboa Water Group
BP2100G1 Tech Sheet Customer: Balboa Water Group Part Number: 56389-02 800 Incoloy 3kW 56390-02 825 Incoloy 3kW 56391-02 Titanium 3kW 56587 800 Incoloy 2kW Custom Box Overlay Box Overlay Part Number N/A
More informationBP601G1 Tech Sheet. Part Number: kW 800 Incoloy kW 825 Incoloy kW Titanium
BP601G1 Tech Sheet Customer: Balboa Water Group Part Number: 56497-02 3.0kW 800 Incoloy 56498-02 3.0kW 825 Incoloy 56499-02 3.0kW Titanium 56562-01 2.0kW 800 Incoloy Custom Box Overlay Box Overlay Part
More informationM-7 Technical Service Manual
2003 M-7 Technical Service Manual Table of Contents Balboa Control Service Checklist Preface....................................4 Tools Required..............................4 System Components Required...................4
More informationFX-2 Control Board ASY-360-XXX Setup and Configuration Guide
FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...
More informationFOR SERVICE TECHNICIAN S USE ONLY
Tech Sheet Do not discard DANGER WARNING Electrical Shock Hazard Only authorized technicians should perform diagnostic voltage measurements. After performing voltage measurements, disconnect power before
More informationInk-Dot Series II Driver
Instruction Sheet P/N 766B Ink-Dot Series II Driver Introduction See Figure. Ink-Dot Series II controllers can have from one to three driver modules. Any existing controller can easily be retrofit with
More informationELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS
ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE 1. Circuit Breaker Tripping 2. Circuit Overload 3. Short Circuit 4. Ground Fault 5. Ground Fault Circuit Interrupter (GFCI) Tripping SAFETY PRECAUTIONS Basic
More informationCRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V
CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...
More informationRemote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System
REDI CONTROLS, INC. Installation, Operation & Maintenance Manual Literature 1033-03 Remote Microprocessor Control Panel for use with the Redi-Purge High Efficiency Purge System MODELS PRG-11/123-C3 & PRG-113-C3
More informationD/E Remote Relay Panel User Guide
D/E Remote Relay Panel User Guide This manual should remain with the unit. D/E Remote Relay Panel Detailed Specifications...2 Environmental Specs...2 Power Supply Requirements...2 Relay Outputs (8)...2
More informationFOR SERVICE TECHNICIAN S USE ONLY
Tech Sheet Do not discard DANGER WARNING Electrical Shock Hazard Only authorized technicians should perform diagnostic voltage measurements. After performing voltage measurements, disconnect power before
More informationES-600 Ozone Controller Operation Manual
ES-600 Ozone Controller Operation Manual Questions about your product? Find answers here: Web: www.ozonesolutions.com/es-600 Phone: 712-439-6880 Ozone Solutions OZONE CONTROLLER Model ES-600 Instructions
More informationManual. Water Vend Controller Model ESDI WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD
Manual Water Vend Controller Model ESDI 030400 WARNING! ELECTRICAL SHOCK HAZARD! AUTHORIZED PERSONNEL ONLY. EXPOSED 120 VAC ON CIRCUIT BOARD THE CIRCUIT BOARD HAS MANY EXPOSED AREAS THAT ARE AT 120 VAC.
More informationFX-2 Control Board ASY-360-XXX Setup and Configuration Guide
FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...
More informationMAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS
MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...
More informationIntegrated Battery Control System LBCS Step-by-Step Setup Guide
Integrated Battery Control System LBCS Step-by-Step Setup Guide 1. Components of the System 2. Components of the System 3. LBCS Overview 4. Battery Connections 5. Sense Board Installation 6. Sense Board
More informationHCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control
HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,
More informationThermometer / Barometer System
TBX USER S MANUAL Thermometer / Barometer System 616TA Pg.2of12 TABLE OF CONTENTS QUICK START GUIDE... 3 INTRODUCTION... 6 SPECIFICATIONS... 6 TERMINAL COMPARTMENT LAYOUT... 7 FEATURES... 8 OPERATION...
More informationTorque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24
Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety
More informationTHE CTB08D LIGHT CONTOLLER
THE CTB08D LIGHT CONTOLLER The CTB08D is a one of the components in the Hobbyist line of Light- O-Rama products. The CTB08D must be used in conjunction with the Light-O-Rama software package. This controller
More informationPM4 INSTRUCTIONS. PM4 WIRING (See Tables 1 & 2 and Wiring Examples)
INSTRUCTIONS The can control 4 independent power sub-districts that can each be set up as either a "Short Circuit Manager" (default) or an "Auto-Reversing Controller." A separate booster can power each
More informationTC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
More informationPRODUCT MANUAL SMOKE-1500 ENGLISH. Version: 1.0
PRODUCT MANUAL SMOKE-1500 ENGLISH Version: 1.0 CONTENTS Warning 1 Caution 3 Please note: 3 Important 3 Description 4 Figure 1 SMOKE-1500 Functions 5 Getting ready 6 Set Up 6 DMX Connector Pin Assignment
More informationTARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation
TARA CONTROLS AGC-5 UCI Random Start USER S GUIDE With Optional Warning Flashes for the Hearing Impaired TARA CONTROLS by Cartessa Corporation 4825 Cincinnati-Brookville Road Shandon, Ohio 45063 Phone:
More informationEco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features
Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use General and New Features The OS-6 is an industrial grade Ozone controller and monitor. The OS-6 design has been optimized for accuracy, ease
More informationDim levels for each system output may be controlled by any of the following methods:
Applied Electronics Bravo Series Dimming System Rack-Mount Architectural l SA12/2400A and l SA12/2400E Setup and Operation Instructions 1.0 Scope This document details the setup and operation requirements
More informationNew 30AA and 31AA Electronic Motor Protection Modules. Application Bulletin 128
New 30AA and 31AA Electronic Motor Protection Modules Application Bulletin 128 Application Bulletin Number: 128 Release EN: D09910 Date: 4/19/96 Revision EN: Z27301 Date: 10/2/15 Subject: New 30AA and
More informationETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features
Table of Contents Drive Features... 1 Drive Specifications... 2 Certifications... 3 Installation - Drive Dimensions... 3 Motor Dimensions (mm)... 4 Drive Mounting... 4 Wiring... 5 I/O Terminals... 9 Menu...
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More informationMeasure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.
Product No. 99-600-91 Rev. B Page 1 of 8 MCG Surge Protection Model 160MXT Installation Instructions Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,
More informationISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL
ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 18 Input module (selectable polarity) with 3 outputs (selectable polarity) with 1 analog (selectable 0-5V or 4-20mA)
More informationADDENDUM FOR 20, 27, & 28 OPTIONS
ADDENDUM FOR 20, OPTIONS GENERAL The 20, 27, and 28 option provides for an alarm contact OR an AC transfer switch on EXELTECH XP Series inverters. The alarm relay monitors the inverter s AC output and
More informationA0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Document Number: 9100-127-2301-99 Release Date: 2/2/15 A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS DO NOT let any supply cords touch hot surfaces higher
More informationINSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationRE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007
RE-82 RACK MOUNT DIMMER 8 X 2400Watts OWNERS MANUAL Revision 2.4 11/29/2007 Page 2 of 8 RE-82 CONTROL PANEL DESCRIPTION The RE-82 is an 8 channel dimmer with a maximum capacity of 2,400 watts per channel
More informationXpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide
Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide Xpander Rack Mount 16 5U Gen 3 with Redundant Power (RP) supplies is a rack mount PCI Express (PCIe) expansion enclosure
More informationAC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838
AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838 Installation Checklist Check for components included Read Warning and Cautions Read QuickStart Installation Guide for mounting instructions Read
More informationINSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationOperations Manual HP2000. With 9100 Controller. Self-Heated Oxygen Measurement System
Operations Manual HP2000 With 9100 Controller Self-Heated Oxygen Measurement System Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible
More informationINSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationINSTRUCTION MANUAL ATTENTION. 1-Year Limited Hardware Warranty
INSTRUCTION MANUAL INTERMATIC MULTIPURPOSE CONTROL MECHANISM MODEL: P1353ME ATTENTION READ CAREFULLY BEFORE ATTEMPTING TO INSTALL YOUR INTERMATIC MULTIFUNCTION CONTROL SWITCH. FAILURE TO COMPLY WITH INSTRUCTIONS
More informationModels 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions
299-600-96 Rev. F MCG Surge Protection Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions Important Warranty Information: MCG surge protectors are designed to work at specific voltages
More informationSeries SD-3PB Digital THERMOSTAT + TIMER
SD-3PB Thermostat and Interval Timer in one Unit. This microcomputer based controller consists of two sections: The Digital Timer and Digital Thermostat, working together to control the power switched
More informationXpander Desktop Elite Gen 3 User Guide
Xpander Desktop Elite (see the image at the right) is a portable PCI Express (PCIe) expansion enclosure that enables connection of graphics processing units (GPUs) or other controllers to a host computer.
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationFX2-CHILLER. Digital Control. Operations Manual
FX2-CHILLER Digital Control Operations Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526 www.microair.net Allentown NJ 08501 Fax (609) 259-6601 Introduction: The FX2-CHILLER digital control
More information*740130* 2800, 9500 Series. Cable Companion Motor Power. Cable AC Power. Cable Retrofit Acessories
*00* 00 Senior Swing Control Box 00, 900 Series Retrofit Instructions Retrofit Cables = = WHT = = NO WIRE -00 0V POWER CONNECTION Cable AC Power = = YEL = WHT/ = RED = = WHT/RED Cable Motor Power = =YEL
More informationOPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2
OPERATING PROCEDURES for the Universal Power Supply Series 2 Vanguard Instruments Co., Inc. 1520 S. Hellman Ave. Ontario, California 91761 TEL: 909-923-9390 November 2013 FAX: 909-923-9391 REV. 2 SAFETY
More informationCompact, Low Profile High Rendering, 100% Diffusion
SURFACE MT SERIES PRELIMINARY SPECIFICATION, SUBJECT TO CHANGE WITHOUT NOTICE MT Series Compact, Low Profile High Rendering, 100% Diffusion Trimless, No Visible Hardware Trimless appearance for recessed
More informationNTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY
NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY USER MANUAL Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct
More informationGeneral Specifications. P2-08THM Analog Input
General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Heat Dissipation Enclosure Type Agency Approvals Module Keying
More informationSeries 3000V Input/Output Board
Part E, Section 1 Model Voltage Pump Manifold Control This section covers the following unit configurations. All All All All Vista Standard (V) Vista Pattern (PC) E 1-0 E 1-1 Section E 1 WARNING: Allow
More informationRobocolor II System. users guide
Robocolor II System users guide CONTENTS INTRODUCTION... 3 INSTALLING THE ROBOCOLOR II SYSTEM... 3 OPERATING WITHOUT A LIGHTING CONTROLLER - STAND ALONE... 4 OPERATING STAND ALONE IN MASTER/SLAVE MODE...
More informationCOMFORT CONTROL CENTER SERVICE INSTRUCTIONS
USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center
More informationLM8 - Low Maintenance System Installation and Operation Manual
LM8 - Low Maintenance System Installation and Operation Manual 1 Table of Contents Important Notices............................................ 3 Intellectual Property Advisement....................................
More informationINSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationMulti-Channel RS-232 Current Loop Interface Converter (CLIC)
DECEMBER 1996 CL204A CL208A CL212A CL216A Multi-Channel RS-232 Current Loop Interface Converter (CLIC) CLIC 1/2A,SLO BLO,115VAC 1/4,SLO BLO,230VAC CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.:
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationUCL & Color Logic. 4.0 LEDs. Installation Guide. LxCUSxxxxx, SP05xxLEDxxx & SP05xxSLEDxxx. Universal ColorLogic ColorLogic. 4.
UCL & Color Logic 4.0 LEDs Installation Guide Universal ColorLogic ColorLogic 4.0 LEDs Universal CrystaLogic LxCUSxxxxx, SP05xxLEDxxx & SP05xxSLEDxxx Copyright 2014 Hayward Industries Table of Contents
More informationWireless Fixture Adapter (WFA100-SN) Installation Instructions
Installation Instructions The Daintree Wireless Fiture Adapter () forms part of Daintree s Controlscope Manager (CSM) in commercial and industrial buildings. It transmits and receives messages over the
More informationKEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood TABLE OF CONTENTS 1 Optional module 13: 3-wires module... 1 2 Installation... 2 3 OM13 module setting and configuration... 8 4 OM13
More informationISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION
ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 12- Relay Board P/N 103190 and 103338 PAGE 1 of 13 1. REVISI LOG... 2 2. OVERVIEW... 3 2.1. PART NUMBERS... 3 2.2. MODULE
More informationPN PSTK-120 PowerSwitch Tail 120vac Kit PN PSTK-240 PowerSwitch Tail 240vac Kit
CAUTION: Please make sure you have or have access to the skills necessary to assemble and use this product. Always secure the case with the included screws before applying electrical power to the power
More informationSMART SHOT CONTROLLER FLUID USERS GUIDE
SMART SHOT CONTROLLER FLUID USERS GUIDE Pg. 2 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER CONFIGURATIONS 4 FLOAT/SENSOR WIRING 5 TOP AND BOTTOM FLOAT/SENSOR
More informationBeam Stage Light (RGBW)
40-Watt MOVING LED Beam Stage Light (RGBW) USER S MANUAL www.monoprice.com TABLE OF CONTENTS SAFETY WARNINGS AND GUIDELINES... 3 INTRODUCTION... 4 PACKAGE CONTENTS... 4 FEATURES... 4 PRODUCT OVERVIEW...
More informationAutomation Interface Requirements for System I/O Interface of a DPC I Welding System
- 1 - Automation Interface Requirements for System I/O Interface of a DPC I Welding System The DPC I welding system offer several features that are intended to communicate with automation. These features
More informationThis document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.
SM5/Gauntlet Stepmill Power Trace Applies to: SM5 (150005) + Gauntlet (150015) This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills. Latest Rev. Warning: the
More informationT1203 DME, ATC, LRA DISCRETE FUNCTION INTERFACE UNIT
OPERATION MANUAL T1203 DME, ATC, LRA DISCRETE FUNCTION INTERFACE UNIT MANUAL NUMBER: 06-1203-01 (Hard Copy) E6-1203-01 (CD) REVISION: 0 DATE: 03/26/2007 WARNING: INFORMATION SUBJECT TO EXPORT CONTROL LAWS
More informationFX 2 Instruction Manual
FX 2 Instruction Manual Climma Compact Version Annapolis MD USA 301 352 6962 info@veco-na.com Introduction: The FX2-DX digital controller operates onboard air conditioning equipment to provide room temperature
More informationMSPA CONTROLLER INSTALLATION AND USER MANUAL
MSPA CONTROLLER INSTALLATION AND USER MANUAL 2 Astrel Index 1. General warnings 05 1.1. Responsibility of the user 05 1.2. Accessing the live parts 06 1.3. Precautions when handling the board 06 1.4. Installation
More informationPANEL MOUNT INTERCOMS
PANEL MOUNT INTERCOMS INSTALLATION AND SERVICE INSTRUCTIONS FOR MODELS AD-26P, AD-27P, AD-56P, and AD-57P Address all communications and shipments to: Electrical Products Division 2645 Federal Signal Drive
More informationPart Numbers SNAP-IT-EMU1
Features Monitors power usage for a 3-phase electrical device such as an HVAC system, engine, or pump Plots realtime and historical energy usage data in an easy-to-use HMI Sends email notification when
More informationBTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual
BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors Installation and Operation Manual BTU-4D/BTU-4D-I Installation and Operation Manual Rev E Table of Contents Introduction... 1 TEMP OUTDOOR Sensor... 1
More informationPhase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:
Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss
More informationInstruction Manual. M Pump Motor Controller. For file reference, please record the following data:
Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager
ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 Total System Manager PAGE 1 of 17 1. REVISION LOG... 2 2. SYSTEM OVERVIEW... 3 2.1. SCOPE... 3 2.2. FEATURES... 3 3. OPERATIONAL
More informationSIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL
More informationKBMG MULTI-SPEED BOARD
TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this
More informationTEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company
TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display HTC 5 Features Australian Made and designed Power can be either 24V or 240V AC 10 Amp (Resistive) Potential free relay contacts
More informationDigital Clamp-on Meter Instruction Manual
255 Digital Clamp-on Meter Instruction Manual TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 3. Declaration of Conformity...4 B. SAFETY CONSIDERATIONS...5 C. TECHNICAL