1 DAM-DA D/A converter Datasheet Overview: DAM module is a new generation data acquisition and control system based on modular embedded systems. Adopting standard DIN35 rail mounting package is simple, flexible respond to various field applications. They establish networks through RS485, RS232, Ethernet and other means of communication. DAM-DAis the analog input series module can simultaneously capture two differential or single-ended signal. The acquisition accuracy is 12 bit. Widely used to collecting various voltage and current signals on industrial site. Such as signals from a variety of sensors, transmitters, thermocouple can be gathered through it. DAM-DA is with galvanic isolation technology and watchdog technology, effectively guaranteeing safe and reliable equipment operation. Product Features: embedded real-time operating system Out signal range: ± 20mA, ± 10V, ± 5V Products Application: Remote monitoring and data acquisition Intelligent Building Control ± 2.5V, ± 1V, ± 200mV, ± 100mV, ± 50mV Security Products and Security Project Out Channels: 2 single-ended DA converter resolution: 12 Bit Measuring Accuracy: ± 0.2% (typical) Sampling rate: 20 times / sec (all channels) Wide range power supply: 8-32V DC Address / Baud rate / range configurable by the user Industrial control on site Warehousing and monitoring Medical, industrial product development Food and beverage industry Packaging and Material Transfer Electronics Manufacturing Supports MODBUS RTU protocol Smart home system ± 15KV ESD protection Isolation voltage: 3000V DC Operating temperature range: Industrial grade plastic shell, the standard DIN35 rail mounting info@amazingelectronic.com Page 1 of 15
2 Model Series: DAM-DA Model NO.: DAM-DA DAM-802x DAM-804x DAM-808x DAM-902x DAM-904x DAM-908x Function type Serial RS232/485 to analog signal General 2 channel analog input General 4 channel analog input General 8 channel analog input Multi-range 2 channel analog input Multi-range 4 channel analog input Multi-range 8 channel analog input Summarize: DAM-DA products achieve the host RS-485/232 interface signals isolation to standard analog signal, to control the remote device. DAM-DA products can be applied to RS-232/RS-485 bus industrial automation control systems,4-20ma,0-5v,0-10v and other standard signal output, used to control the implementation of industrial field devices, control devices and display devices, etc. and so on. Products include power supply isolation, signal isolation, linearization, D / A conversion and RS-485 serial communication. Each serial port of the maximum 256 DAM-DA series of modules, means of communication using ASCII code or MODBUS RTU communication protocol communication protocol, its instruction set compatible with the ADAM modules, the baud rate is set by the code, with other manufacturers control module hanging in the same RS-485 bus, to facilitate computer programming. DAM-DA series of products are based on single chip of intelligent monitoring and control systems, all the user to set the calibration value, address, baud rate, data format, checksum status and other configuration information is stored in nonvolatile memory EEPROM inside. DAM-DA series of products according to industry standard design, manufacture, signal output / communication interface isolation, can withstand 3000VDC isolation voltage, anti-interference ability, and high reliability. Operating temperature range: - 45 ~ +80. Figure1 DAM-DA figure image info@amazingelectronic.com Page 2 of 15
3 DAM-DA Function Introduction: DAM-DA signal isolated D/A converter module can output one channel voltage/current signals, or 2-channel common ground and isolation current/voltage signals. 1. Analog signal output: 12-bit accuracy, have been calibrated all signal input before ex-factor. Also, Users can program himself; two output signals must be same when testing two signals. 2. Communication software: Communication Interface: 1 standard RS-485 interface or 1 standard RS-232 interface Communication agreement: Standard ASCII, MODBUS RTU, can make network communicate with PLC,RTU or watch software. Data format: 10-bit, 1 start bit, 8 data bits, 1 stop bit. Communication address (0~255) and baud rate ( bps),Max. Communication distance: 1200m, connect by both twists shield cable.±15kv ESD protection, communication response time is less than 100mS. Anti-jamming: Set checksum according to need. Its inside contains MOMENTARY bate diode, can restrain surge impulse, protect modules. Model Selection: DAM-DA - Communication port: O Output voltage or current value 485: input is RS-485 interface 232: input is RS-232 interface U1:0-5V U2:0-10V U3:0-75mV U4:0-2.5V U5:0-±5V U6:0-±10V U7:0-±100mV U8:User-define A1:0-1mA A2:0-10mA A3:0-20mA A4:4-20mA A5:0-±1mA A6:0-±10mA A7:0-±20mA A8:User-define Example: 1: Model:DAM D/A -485-A4 represents RS-485 interface input,4-20ma output 2: Model:DAM D/A -232-U1 represents RS-232 interface input,0-5v output info@amazingelectronic.com Page 3 of 15
4 DAM-DA General Parameters: +25,Vs is 24VDC) Outputs: Voltage / Current Accuracy: 0.2% Output Maladjustment: current output ±0.5 ua/, voltage output ±0.1mV/C Temperature Drift: ±20 ppm/ (±30 ppm/,max) Output Resistance: current output: 350Ω (4-20mA/0-20mA/0-±20mA output) Voltage output: 10mA (0-5V/0-10V/0-±5V output) Communications Protocol RS-485 or RS232 ASCII format, MODBUS Baud Rates Software Selectable ( bps) Address (0~255) Software Selectable Response Time: 100 ms, max Operation Power Supply: +8~32VDC (inner protection circuit of overvoltage and reverse) Power Loss: <1.5W Operation Temperature: - 45 ~ +80 Operation Humidity: 10 ~ 95% (non-condensing) Storage Temperature: - 45 ~ +80 Storage Humidity: 10 ~ 95% (non-condensing) Isolation Input/Output: 3KVDC,1 minute, leak current:1ma Interface and power supply are common-ground. Endure Impact Voltage: 3KVAC, 1.2/50us (peak value) Mechanical Dimensions: mm x 79 mm x 25 mm Footprint Definition: Pin Name Definition Pin Name Definition 1 PW+ Power + 7 Out0+ Analog output 0 out+ 2 GND Power- 8 GND1 Analog output 0 out- 3 INIT Initial State 9 NC NC 4 D+ RS-485 signal+ 10 Out1+ Analog output 1 out+ 5 D- RS-485 signal- 11 GND1 Analog output 1 out- 6 GND Power-, digital signal output GND 12 NC NC Form1: pin definition info@amazingelectronic.com Page 4 of 15
5 Figure2 DAM-DA Wiring diagram Figure3: DAM-DA Block diagram Initialization DAM-DA Module: All DAM-DA modules use RS-485 network, must distribute a only one address, between 00 and FF (hexadecimal), but, all new DAM-DA modules use a factory initialization set. As follows: Address: 00 (hexadecimal) Baud rate: 9600 bps Checksum: disabled Because address codes of new module are the same, their address will conflict to other modules, you must reconfigured every analog input address when you configure system. You can amend DAM-DA address by set command after connecting DAM-DA power line and RS485. Baud rate,checksum state also need be adjusted according to users demand. All these amendments should execute under default state. info@amazingelectronic.com Page 5 of 15
6 Let the modules into default state method: All DAM-DA modules have a Pin mark with INIT. Connect INIT Pin to ground (GND pin), then connect power supply, and then it is in default state. Its set as follows: Address: 00 Baud rate 9600 bps Checksum: disabled Then, can amend the DAM module s parameter as baud rate, checksum, and state by set command, and choose communication protocol trough set module communication protocol command. When not clear the module s specific configuration, can also make modules enter into default state through install jumping wire, then re-configure the module. If users want to set module in ModBus RTU communication Protocol, please see below description of MODBUS ASCII communication protocol command set: Every command is insists of a series characters, such as leading code, address ID, command, checksum, end symbol (cr). Except ** synchronous command, commands have effects on one module each time. Command format: (Leading Code)(Addr)(Command)[data][checksum](cr) (Leading Code) is the first letter of command. All commands need a leading code. such as:%, $,#,@, Character (Addr) is module address code, default value range is 00~FF (hexadecimal), 2- Characters (Command) represents command code or variable value Variable Length [data] some output command need data Variable Length [checksum] represents optional parameters, only need it when checksum is enabled. 2 -Characters (cr) terminating character, value is 0x0D 1- character When checksum is enabled, [Checksum] is required. Command and response must append checksum characters. Checksum is used to check all input command, to help you find the errors between host computer and module Calculating Method: two-character (hexadecimal), is the sum of all sending characters ASCII, then AND 0xFF. Example: Disable checksum command: $002(cr) response:! (cr) Enable checksum command: $002B6 (cr) response:! A9 (cr) $ = 0x24 0 = 0x30 2 = 0x32 B6=(0x24+0x30+0x30+0x32) AND 0xFF! = 0x21 0 = 0x30 2 = 0x32 6 = 0x36 A9=(0x21+0x30+0x30+0x30+0x32+0x30+0x36+0x30+0x30) AND 0xFF info@amazingelectronic.com Page 6 of 15
7 Command Response: Response message depends on all kinds of command. Command also insists of some characters, including leading code, variable and end symbol. Response message s leading code has 2 kind,! or > represents valid command,? stands for invalid. Through check response message can monitor command is valid or not. Remark: 1, under some circumstances, many command use similar command format. Make sure the address you used in the command is right, if you use wrong address, and this address represents another module, then the command will effective in another module, then cause to wrong. 2, Must use capital letter input command Analog Output Module Command Table: 1 Set Channel N Analog Output Value Command 2 Set Channel N Reset Analog Output Value Command 3 Set Analog Output Module Command 4 Read Set State 5 Offset Calibration 6 Span Calibration 7 Read Module Name 8 Channel N Analog Output Read-back Command 9 Set Communication Protocol Commands 1 Set N-Channel Analog Output Value Command Describe: As the current configuration data format, set analog output module N-channel output value Syntax:#AAN(data)(cr) # delimiter character AA is (range 00-FF) represents the 2-character hexadecimal address of the module. N Channel code 0 or 1 (cr) is the terminating character, carriage return (0Dh) Response : >(cr) command is valid.?aa(cr) invalid command or nonlicet operation > delimiter character There will be no response if the module detects a syntax error or communication error or if the specified address does not exist. Example: Command # (cr) Response >(cr) The channel 0 output value is mA at address 23H. 2 Set Channel N Reset Analog Output Value Command Describe: Set Channel N Reset Analog Output Value as present data formats. Syntax:#AASN(data)(cr) info@amazingelectronic.com Page 7 of 15
8 # delimiter character AA module address (range 00-FF) hexadecimal S set reset analog output value N Channel code 0 or 1 (data) set channel N reset output analog value.the data format is in Engineering Units,Percent of FSR, Two s complement hexadecimal. Refer to Chapter 3 Command Set. (cr) is the terminating character, carriage return (0Dh) Response : >(cr) command is valid.?aa(cr) invalid command or nonlicet operation > delimiter character There will be no response if the module detects a syntax error or communication error or if the specified address does not exist. Example: Command #23S (cr) Response >(cr) Channel 0 reset output is mA at address 23H. 3 Set Analog Output Module Command Describe: Set address, output range, baud rate, data format, checksum, status to analog output module. Configuration information is stored in nonvolatile memory EEPROM. Syntax:%AANNTTCCFF(cr) % delimiter character AA is (range 00-FF) represents the 2-character hexadecimal address of the module. NN New module hexadecimal address, NN range is 00-FF. TT hexadecimal represents type code. DAM-DA must be set 00. CC hexadecimal represents baud rate code. Baud rate code Baud rate baud baud baud baud baud baud baud baud Form2 Baud rate code info@amazingelectronic.com Page 8 of 15
9 FF DAM-DA (8-bit parameter) hexadecimalre presents data formats,checksum. Bit7 Bit 6 Bit 5 Bit 4 Bit 3 Bit2 Bit 1 Bit 0 Form 3 Data format, checksum Bit7:Reserved bit (set to 0) Bit6:checksum states, if 0:Disabled, if 1: Enabled Bit5-bit2:Not use (set to 0) Bit1-bit0:Data Format Bit 00:Engineering Units 01:% of FSR 10:Twos complement hexadecimal 11:ohms Response Syntax:!AA(cr) command is valid?aa(cr) command is invalid or nonlicet operation, or do not set up line before changing baud rate or checksum! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. AA represents module address If you configure module for the first time, A=00 NN equals to new address. If reconfigure module changing address, input range, and data formats, AA equals to present or new address. If reconfigure module changing baud rate or checksum state, must install command string, make them in listening mode, module address is 00H, also AA=00H, NN=present or new address. There will be no response if the module detects a syntax error or communication error or if the specified address does not exist. Example: Command % (cr) Response!11(cr) Description: % delimiter character 00 indicates analog input module initial address that you want to set is 00H 11 indicates new module hexadecimal address is 11H 00 indicates type code, DAMDA must be set indicates baud rate: 9600 baud 00 indicates data format is Engineering Units,checksum is disabled 4 Read Set State Describe: Read set for the specified a analog output module. Syntax: $AA2(cr) $ delimiter character AA module address, (range 00-FF) hexadecimal info@amazingelectronic.com Page 9 of 15
10 2 indicates read set state command Response Syntax:!AATTCCFF(cr) command is valid?aa(cr) command is invalid or nonlicet operation! delimiter character AA represents module address TT Type Code CC Baud rate code, form 3 FF form 4 There is no response if the module detects a syntax error or communication error or if the specified address does not exists. Example: command $302(cr) Response!300F0600(cr)! delimiter character 30 indicates analog input module address is 30H 00 indicates that output type code 06 represents that baud rate is 9600 baud 00 represents that data format is Engineering Units, disable checksum 5 Offset Calibration Command Describe: Calibrates an analog output module channels N to correct for offset errors Syntax: $AA1N(cr) $ delimiter character AA module address, (range 00-FF) hexadecimal 1 represents offset calibration command N channels code 0~1 Response:! AA (cr) command is valid?aa(cr) command is invalid or nonlicet operation! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. AA represents module address Products have been calibrated, user can use them directly. After calibrating offset command, then calibrate gain errors. In the calibration, analog output modules need to be calibrated channel connected to the multimeter to monitor the output signal, through the first command set command to set the analog output, regulated to multimeter inside shows the value of the output signal is zero, and then enter the calibration bias shift command, see the specific calibration methods calibrate the module sections. There is no response if the module detects a syntax error or communication error or if the specified address does not exist. info@amazingelectronic.com Page 10 of 15
11 Example: command $2310(cr) Response!23 (cr) Calibrate offset channel 0 at address 23H module. 6 Span Calibration Description: Calibrates an analog output module channles N to correct for gain errors Syntax: $AA0N(cr) $ delimiter character AA module address, (range 00-FF) hexadecimal 0 represents gain calibration commandre N channels code 0~1 Response:!AA(cr) command is valid?aa(cr) command is invalid or illegal operation! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. AA represents module address Products have been calibrated, user can use them directly. After calibrating offset command, then calibrate gain errors. In the calibration, analog output modules need to be calibrated channel connected to the multimeter to monitor the output signal, through the first command set command to set the analog output, regulated to multimeter inside shows the value of the output signal is zero, and then enter the calibration bias shift command, see the specific calibration methods calibrate the module sections. There is no response if the module detects a syntax error or communication error or if the specified address does not exists. Example: command $2300(cr) Response!23 (cr) Calibrate gain errors channel 0 at address 23H module. 7 Read Module Name Description: Return the module name from the specified analog output module Syntax: $AAM(cr) $ delimiter character AA module address, (range 00-FF) represents the 2-character hexadecimal M represents Read module name command Response:!AA(ModuleName)(cr) command is valid?aa(cr) command is invalid or nonlicet operation! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. AA represents input module address (ModuleName) is DAM,DAM so on, represents module type There is no response if the module detects a syntax error or communication error or if the specified address does not exist. info@amazingelectronic.com Page 11 of 15
12 Example: Command $08M(cr) Response!08ISODA (cr) Counter Module is ISODA at adress 08H 8 Channel N Analog Output Read-back Command Description: Analog output module Channel N Analog Output Value Read-back. Command Syntax: $AADN(cr) $ delimiter character AA module address, (range 00-FF) hexadecimal D Analog output read-back command N Channel code 0 or 1 Response Syntax:!AA(data)(cr) command is valid?aa(cr) command is invalid or illegal operation! delimiter character AA represents input module address (data) represents back to read the output channel N analog data. The data format is in Engineering Units Percent of FSR, Two s complement hexadecimal. Refer to Chapter 3 Command Set. There is no response if the module detects a syntax error or communication error or if the specified address does not exists. Example: Command $23D0 (cr) Response! (cr) Channel 0 present output value is mA at address 23H. 9 Set Communication Protocol Commands Description: Choose ASCII command set or MODBUS RTU as operation protocol Command Syntax: $AAPV(cr) $ delimiter character AA module address, (range 00-FF) hexadecimal P command code V Protocol code. 0: ASCII command set; 1: MODBUS RTU Response:!!AA (cr) command is valid?aa(cr) command is invalid or nonlicet operation! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. AA represents output module address There is no response if the module detects a syntax error or communication error or if the specified address does not exists. Example 1: Command $00P1(cr) Response!00 (cr) info@amazingelectronic.com Page 12 of 15
13 Choose MODBUS RTU protocol Example 2: Command $00P0(cr) Response!00 (cr) Choose ASCII command set Output Ranges& Data Formats: Analog output has three data formats: 00:Engineering Unit 01:% of FSR 10:Twos complement hexadecimal Form 4 A4:4-20mA Output Range Data Format Max. Min. Engineering Unit % of FSR Twos complement hexadecimal FFF 333 A3:0-20mA Engineering Unit ± % of FSR ± Twos complement hexadecimal FFF 000 U1:0-5V Engineering Unit ± % of FSR ± Twos complement hexadecimal FFF 000 U2:0-10V Engineering Unit ± % of FSR ± Twos complement hexadecimal FFF 000 U5:0-±5V Engineering Unit % of FSR Twos complement hexadecimal FFF 000 U8/A8:User define Engineering Unit ± % of FSR ± Twos complement hexadecimal FFF 000 A7:0-±20mA Engineering Unit % of FSR Twos complement hexadecimal FFF 000 U6:0-±10V Engineering Unit % of FSR Twos complement hexadecimal FFF info@amazingelectronic.com Page 13 of 15
14 Example: 1. Output range A4:4-20mA, setting output value for 4mA Engineering Units user command: # (cr) % of FSR user command: # (cr) Twos complement hexadecimal user command: #010333(cr) 2. Output range U1:0-5V, setting output value for 3V Engineering Units user command: # (cr) % of FSR user command: # (cr) Twos complement hexadecimal user command: #010999(cr) Module Calibration Products have been calibrated, the user can use directly without calibration. In the process, you can use the product calibration function to re-calibrate the module. In the calibration, the module need use a high-precision multimeter to monitor the module output signal. In order to improve calibration precision, suggest doing as the following meters: A five and a half or more high-precision voltage / current measurement instrument for monitoring the accuracy of the output signal Calibration Process: 1. Select the output channel to be calibrated in accordance with the scope of the module connected to the corresponding output voltage or current measurement instruments. 2. Set analog output modules need to calibrate the output of the channel zero signals, typically 0mA, 4mA or 0V and so on. Through the first command set command to set the analog output, adjust to the measuring instrument inside shows the value of the output signal is zero. 3. Until the signal stabilized, the analog output module to send $ AA1N offset calibration command (N representing the current channel being calibrated code, 0 or 1). 4. Set analog output modules require full-scale calibration channel output signal. Through the first command set command to set the analog output, adjust to the measuring instrument where the output signal is shown in full scale value. 5. Until the signal stabilized, the analog output module to send $ AA0N gain calibration command (N representing the current channel being calibrated code, 0 or 1). 6. Finished MODBUS RTU : The device is set ASCII command as default protocol, if need change to MODBUS RTU, follow below step to change: 1. Short connecting INIT(PIN 3) and GND(PIN 6) 2. Correctly link Power and communication interface cables 3. Switch on power supply, the module automatically enter the default state, communication address is 00, the baud rate of Wait for one minute, Module initialization 5. Send command $00P1(cr), response should be!00(cr) 6. Switch off power supply, break off INIT and GND 7. Now device successfully in MODBUS RTU protocol The Modbus function codes of modue support are 03 and 06. Modbus data content and output info@amazingelectronic.com Page 14 of 15
15 corresponding relation see Form 4,it is the same as the character data format for Twos complement hexadecimal Register Specification: Addr Content R/W Description 4X Out0(0x0000-0x0FFF) Read/Write Output data of Channel Out1(0x0000-0x0FFF) Read/Write Outpur data of Channel S0ut0(0x0000-0x0FFF) Read/Write Sout1(0x0000-0x0FFF) Read/Write Dimension: (unit:mm) Contact us ADD: No. 520, Building 1, Jiamei Industrial Park, Longwei Road, Futian District, Shenzhen,China info@amazingelectronic.com Page 15 of 15
Signal Isolators & Conditioners
RS485/232 to Analog Signal Converter Signal Isolators & Conditioners (D/A Converter,WJ31 series) Features: >> RS-485/232 interface, isolation convert standard analog signal output >> Analog signal output
More informationSignal Isolators & Conditioners
Analog Signal to RS485/232 Converter Signal Isolators & Conditioners (WJ21 series A/D Converter) Features: >> Analog signal acquisition, isolated RS-485/232 output >> 12-bit AD converter, testing accuracy>0.1%
More informationRTD Temperature acquisition converter WJ25
8-CH Thermocouple Signal to RS485/232 Acquisition Converter (WJ27 series 24Bits A/D Converter, data acquisition) Features: >> Eight channels thermocouple signal acquisition, isolated converter RS-485/232
More informationSignal Isolators & Conditioners
WJ21 series Analog Signal to RS485/232 Converter (A/D Converter) Features: >> Analog signal acquisition, isolated RS-485/232 output >> 12-bit AD converter, testing accuracy>0.1% >> Can Program and calibrate
More informationJSD81 series products are based on SCM's intelligent monitoring and control system, users set the calibration value,
8-Channel Analog Signals to RS485/232 Converter(A/D Converter JSD81 series) Features: 8-CH analog signal acquisition/isolation,rs-485/232 output 24-bit AD converter, testing accuracy>0.05% Can Program
More informationAnalog signal to RS485 or RS232 Converter, A/D Converter
Analog signal to RS485 or RS232 Converter, A/D Converter Features: Analog signal acquisition, isolated RS-485/232 output 12-bit AD converter, testing accuracy>0.1% Can be remotely reconfigured for modules
More informationSignal Isolators & Conditioners
8-ch DI Switch Signal to RS485/232 Converters (WJ62 Series) Features: >> Eight channels switch signal acquisition,isolated RS-485/232 output >> Each input channel adopts optical isolation >> Can read level
More informationSignal Isolators & Conditioners
4-ch DI 4-ch Relay Output, RS485/232 Remote Acquisition I/O (WJ70 Series) Features: >> Four switch input, four relay output >> Can read input level status via the RS-485/232 interface >> Can set output
More information8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user
8 Channel Analog Input Module Datasheet User s Manual Overview: DAM module is a new generation data acquisition and control system based on modular embedded systems. Adopting standard DIN35 rail mounting
More informationISO AD A08 8-channel isolated 4-20mA Signal Acquisition Module ⅠProduct Introduction
ISO AD A08 8-channel isolated 4-20mA Signal Acquisition Module ⅠProduct Introduction Features: 8-ch 4-20mA signal acquisition, signal between channel to channel is isolated RS-485/232 output can adjust
More informationInput Channels: 4 differential or four single-ended. Address / Baud rate / range configurable by the user
DAM-Series User Manual Amazing Electronic (HK) Limited User s Manual Overview: DAM module is a new generation data acquisition and control system based on modular embedded systems. Adopting standard DIN35
More informationI-7021, I-7022, I-7024, M-7022, M-7024 and M-7028 Series User Manual
I-7021, I-7022, I-7024, M-7022, M-7024 and M-7028 Series User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date
More informationZB-2024 Series User Manual
ZB-2024 Series User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser. Warning
More information4.6 Digital I/O and Relay Output Module Command
4050, 4052, 4053, 4060 Chapter 4 4.6 Digital I/O and Relay Output Module Command Command Syntax Command % AANNTTCCFF C onfiguration Sets the address, input range, baud rate, and/or checksum status, to
More informationEX9017H-M is a analog input module with 8 input channels. Eight channels are differential type and individual channel configuration support.
1.1 Introduction EX9017H-M is a analog input module with 8 input channels. Eight channels are differential type and individual channel configuration support. Specifications: Interface: RS-485, 2 wires
More informationOMR-6021 Analog Output OMR Channel Analog Output
OMR-6021 Analog Output OMR-6024 4-Channel Analog Output Contents 1. INTRODUCTION...1-1 1. 1. ABOUT THE OMR ANALOG OUTPUT MODULES 1-1 1. 2. OVERVIEW OF OMR-6021 1-1 1. 3. OVERVIEW OF OMR-6024 1-4 2. INITIALIZATION
More informationSY Series Data Acquisition Isolation Transmitter
Ethernet Multi-channel Analog Signal Isolated Data Acquisition Transmitter The Internet of Things/Local Area Network Analog Isolated Data Acquisition Transmitter SY AD 08-RJ45 Features: Directly convert
More information8017, 8018, 8019, 8017, M-8018, M-8019 Series User's Manual
8017, 8018, 8019, 8017, M-8018, M-8019 Series User's Manual Warranty All products manufactured by SuperLogics are under warranty regarding defective materials for a period of one year from the date of
More informationNuDAM. ND-6021 Analog Output ND Channel Analog Output
NuDAM ND-6021 Analog Output ND-6024 4-Channel Analog Output @Copyright 1996 ADLink Technology Inc. All Rights Reserved. Manual first edition: January 7, 1996 Manual Rev. 2.0: December 5, 1997 Manual Rev.
More informationI-7000 and M-7000 DIO User Manual
I-7000 and M-7000 DIO User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationI-7000 and M-7000 DIO User Manual
I-7000 and M-7000 DIO User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationWarranty. Warning. Copyright. Contact Us
M-6026U-32 16-channel Universal Input and 16-channel Universal Output Version: 1.0.0 Date: Dec. 2017 Edited by Horse Chien M-6026U-32 User Manual Version 1.0.0 Dec. 2017-1 - Warranty All products manufactured
More informationIsolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW
Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES Single-channel isolated signal-conditioning modules. Accepts outputs from Thermocouple, millivolt, volt and current signals. Complete microcomputer-based
More informationI-7017, I-7018, I-7019, M-7017, M-7018 and M-7019 Series User Manual
I-7017, I-7018, I-7019, M-7017, M-7018 and M-7019 Series User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date
More informationi-7005 and M-7005 User s Manual
i-7005 and M-7005 User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationNuDAM-6011/ NuDAM-6014D NuDAM-6012/D NuDAM-6017 NuDAM-6013/ NuDAM-6018 Analog Input Modules User s Guide
NuDAM-6011/ NuDAM-6014D NuDAM-6012/D NuDAM-6017 NuDAM-6013/ NuDAM-6018 Analog Input Modules User s Guide Copyright 1996~2001 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 5.15: October 2, 2001
More informationOMR-6011/D OMR-6014D OMR-6012/D OMR-6017 OMR-6013 OMR Analog Input Modules
OMR-6011/D OMR-6014D OMR-6012/D OMR-6017 OMR-6013 OMR-6018 Analog Input Modules Contents 1 Introduction... 1-1 1. 1. ABOUT THE OMR ANALOG INPUT MODULES...1-1 1. 2. OVERVIEW OF OMR-6011/D...1-1 1. 3. OVERVIEW
More informationMODEL 9250 Preliminary data sheet
Delivery: ex stock Warranty: 24 months Universal Instrumentation Amplifier for strain gage, potentiometric, DC/DC and incremental sensors MODEL 9250 Preliminary data sheet NEW burster TEDS Highlights Ultra-fast
More information8013,8013D, 8033 User Manual
8013,8013D, 8033 User Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning
More informationADAM Data Acquisition Modules User's Manual
ADAM 4000 Data Acquisition Modules User's Manual ADAM 4000 Series Data Acquisition Modules User s Manual Copyright Notice This document is copyrighted, 1997, by Advantech Co., Ltd. All rights are reserved.
More informationAnalog Input Modules User s Guide
ND-6021 & ND-6024 Analog Input Modules User s Guide Copyright 1996~2001 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 4.00: June 5,2001 The information in this document is subject to change
More informationRS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1
2.1 Communication Cards for PC/IPC P 2-1 2.2 Communication Modules for PAC P 2-2 2.3 Converter/Repeater/Hub/Splitter P 2-3 2.4 Termination Resistor/DC Bias Voltage P 2-5 2.5 I/O Modules P 2-6 2.6 I/O Units
More informationTechnical specification
Technical specification EXPERT i/o extension modules Version 01.00.00 23-02-2017 This manual contains technical documentation which allows for easy installation and use of the i/o extension module product
More informationD7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES
11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet
More informationCAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port
CAN485 Wall Mounting CAN to RS-485 Interface Converter Support data conversion between 1 CAN port and 1 RS-485 serial port Support multiple conversion modes like transparent conversion, marked transparent
More informationioselect Z-NET Z-SG Bridge Input Isolating I/O Module
-wire Bridge Connection Excitation for to 30 Ω Load Cells 00 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS8 Modbus RTU Superior Flexible Power:
More informationI-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS
I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog
More informationRS-485 I/O Modules: ADAM-4000
RS-485 I/O Modules: ADAM-4000 23 ADAM-4000 Series Overview ADAM-4000 Series Remote Data Acquisition and Control Modules Overview 23-2 and Controller Module Selection Guide 23-4 I/O Module Selection Guide
More informationMPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS
MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control
More informationSuperLogics 8000 Series Analog Input Modules
SuperLogics 8000 Series Analog Input Modules SuperLogics 8000 Series of compact remote data acquisition modules provides intelligent signal conditioning, analog I/O, and digital I/O. Through a cost-effective
More information1. Introduction. Note: For EX9050HD the (INIT*) switch located on the rear side of the module.
1. Introduction EX-9050HD/HD-M/ provides 8 non-isolated digital output(sink) channels and 8 non-isolated digital input(source)channels All input/output channels are single-ended with common ground (See
More information8520/8520R. User Manual
/R User Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Disclaimer SuperLogics
More informationUser Manual ADAM 4000 Series. Data Acquisition Modules
User Manual ADAM 4000 Series Data Acquisition Modules Copyright The documentation and the software included with this product are copyrighted 2018 by Advantech Co., Ltd. All rights are reserved. Advantech
More informationIntech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to
More informationTransducers for Pt-100/1000, Resistors
Transducers for Pt-100/1000, Resistors Microprocessor-based technology General Description Isolating transducers with digital programming of ranges, for DIN-rails or for printed circuit boards. Modules
More informationThe I-7530A RS-232/485/422 to CAN Converter
The I-7530A RS-232/485/422 to CAN Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery
More informationPROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1
5.1 Overview P 5-1 Selection Guide - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P 5-2 5.2 Converters & Repeaters P 5-3 5.3 Gateways P 5-5 5.4
More informationFeatures and Benefits. Certifications
iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters
More informationMDA-8000 DIO User Manual
MDA-8000 DIO User Manual Warranty All products manufactured by Maxthermo-Gitta are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationWolf series Remote IO Modules User s Manual
Wolf series Remote IO Modules User s Manual Copyright The description, exemplary and software applied to Wolf Series Module are the copyright of Advanio Co., Ltd. Any modification, reproduction, duplication,
More informationTRP-C68. 8-Channel Analog Input to Digital Output Isolated Module Support ASCII and Modbus RTU protocol USER S MANUAL. June Rev 1.
TRP-C68 8-Channel Analog Input to Digital Output Isolated Module Support ASCII and Modbus RTU protocol USER S MANUAL June. 2007 Rev 1.0 Trycom Technology Co.,Ltd 1F, No.2-11,Sihu street,yingge Township,
More informationIntech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationUniPak UP448 Bridge Input Isolating Signal Conditioner
6-wire Bridge Connection Excitation for to 350 Ω Load Cells 500 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS85 Modbus RTU Superior Flexible
More informationThe I-7530A-MR Modbus RTU to CAN Converter
The I-7530A-MR Modbus RTU to CAN Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery
More informationD1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES
D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;
More informationNuDAM-6050 NuDAM-6052 NuDAM-6053 NuDAM-6054 NuDAM-6056 NuDAM-6058 NuDAM-6060 NuDAM Digital I/O Modules
NuDAM-6050 NuDAM-6052 NuDAM-6053 NuDAM-6054 NuDAM-6056 NuDAM-6058 NuDAM-6060 NuDAM-6063 Digital I/O Modules Copyright 1995~2001 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 3.51: March 27, 2001
More informationiothinx 4500 Series (45MR) Modules
iothinx 4500 Series (45MR) Modules Modules for iothinx 4500 Series Feature and Benefits Easy tool-free installation and removal Built-in LED indicators for IO channels Wide operating temperature range:
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationNI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O
DATASHEET NI REM-11115 Analog Output Module for Remote I/O Four voltage output ranges to choose from (0 V to 10V, ±10V, 0 V to 5 V, and ±5V) Two current output ranges to choose from (0 ma to 20mA, 4 ma
More informationFeatures. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System
Features 10/100Mbps Ethernet full duplex Auto Negotiation Support C++/C Modbus/TCP drivers and OPC server Support configuration via built-in Web browsing, (HTML), Device Finder and I/O configuration utilities
More informationDupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications
Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter
More informationThis Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.
This Datasheet for the IC670ALG310 Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V http://www.qualitrol.com/shop/p-14493-ic670alg310.aspx Provides the wiring diagrams and installation guidelines for
More informationFeatures. Target Applications. V1.6 TBS07 RS485 to SDI-12 Converter
The is an interface box for connecting a PC, data logger or telemetry unit to one or more sensors with SDI-12 interface. The connects to a data logger, telemetry unit or other device with RS485 interface
More information8000 DIO Manual Warranty Warning Copyright Trademark
8000 DIO Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning SuperLogics
More informationR1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)
Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationUSER MANUAL. WBI412F41 AC current transducer
Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 989 USER MANUAL WBI2F AC current transducer www.wb-my.com wblch@wbdz.cn Technical Service:
More informationicex-cmtm General specs and Installation guide
icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB
More informationTRP-C68. 8-Channel Analog Input to Digital Output Isolated Module Support ASCII and Modbus RTU protocol USER S MANUAL. Dec Rev 1.
TRP-C68 8-Channel Analog Input to Digital Output Isolated Module Support ASCII and Modbus RTU protocol USER S MANUAL Dec. 2010. Rev 1.2 Trycom Technology Co.,Ltd 1F, No.2-11,Sihu street,yingge Township,
More informationEAZY-CAL LVC-4000 LVDT Signal Conditioner User Manual
EAZY-CAL LVC-4000 LVDT Signal Conditioner User Manual Macro Sensors 7300 US Rt. 130 North, Bldg. 22. Pennsauken, NJ 08110 U.S.A. 856.662.8000 Manual P/N 0653 0006 0000 Rev. E July 3, 2013 AST / Macro Sensors
More informationIsolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage
More informationsmart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...
2 content DISPLAYS... 4 smart meters... 6 panel meters... 7 field displays... 8 display types... 10 loop powered displays... 12 TRANSMITTERS & CONVERTERS... transmitters... 15 converters... 18 serial data
More informationRS 485 Mini Modbus 1AO
RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained
More informationTC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.
LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationDu line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection
Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G 3891 0052 Built-in Dupline channel generator Modbus/TCP Slave 10 and 100 Mbit operation, full or half duplex Twisted pair cables
More informationUSB-1208LS Specifications
Specifications Document Revision 1.1, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.
More informationIsolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Voltage Input 3B30 / 3B31 FEATURES Interfaces, amplifies, & filtersanalog input voltages. Narrow-bandwidth (3Hz) single-channel single conditioning. Module provides simultaneous precision voltage
More informationiologik 4000 Series (M) Modules
iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin
More informationI-7000 DIO Manual Warranty Warning Copyright Trademark
I-7000 DIO Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning ICP DAS assume
More informationmbc082 Bus Converter
BUS CONVERTER RS485 TO 1-WIRE BUS mbc082 mbc082 Bus Converter Document. 10910, Revision - February 2007 2007 CMC Industrial Electronics Ltd. This page intentionally left blank. mbc082 Bus Converter Technical
More informationKTA-250 Anemometer Alarm Card
Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments
More informationReal Time Clock with Temperature Sensor and RS485/Modbus Comunications
Real Time Clock with Temperature Sensor and RS485/Modbus Comunications April 29, 2014 Power 8 20 VDC @ less than 100 MA. Battery connect jumper RS485 Bus Load Jumpers Model: RTC-TI2C Page 1 of 6 Features:
More informationUSER MANUAL. WBI414F21 AC current transducer
1 Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 1989 USER MANUAL WBI1F21 AC current transducer www.wb-my.com wblch@wbdz.cn Technical
More information1. Introduction. 2. Installation MODBUS INTERFACE
5551.C 8473.C MODBUS INTERFACE PIM-MB-1 Modbus Interface 1. Introduction AuCom soft starters can be controlled and monitored across an RS485 serial communication network using the Modbus RTU and AP ASCII
More informationLAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions
ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter
More informationDXp-10 and DXp-15 Weight Transmitter
Precision Force and Weight Measurement Technologies DXp-10 and DXp-15 Weight Transmitter Applica pplications: Inventory Weighing Process Weighing Web Tension Measurement Product Description l Microprocessor
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual
ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following
More informationUSER MANUAL. WBV412U01 AC voltage transducer
Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 1989 USER MANUAL WBV412U01 AC voltage transducer www.wb-my.com wblch@wbdz.cn Technical
More informationPen Drive USB Datalogger!
SINGLE PHASE POWER METER Isolated V/I converter -RS485 Modbus - Datalogger Single-phase power meter RMS, and Voltage/Current Isolated. Signal Converter 1000 VDC / 600 VAC, 10 A AC/DC, Variable frequency
More informationGeneral. Copyright 2013 EXSEN Company. All Rights Reserved. Rev /5/2013 Page 1 of 6
General World smallest and economic solid state electrochemical CO 2 sensor has been developed for the production. It holds many patents in the structure and the materials of the sensor as well as the
More informationSDM-6RO. Expansion Module 6 relay outputs. Manufactured for
Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationSER-4485-SI-M USER S MANUAL
SER-4485-SI-M USER S MANUAL 2017 May Edition Titan Electronics Inc. Web: www.titan.tw The computer programs provided with the hardware are supplied under a license. The software provided should be used
More information2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan
OGM220 Series Dual Channels NDIR CO 2 Gas Sensor Module Introduction OGM220 series is a dual channels NDIR module having a digital output directly proportional to CO 2 concentration. OGM220 is designed
More informationI-7083/7083D/7083B/7083BD
I-7083/7083D/7083B/7083BD User s Manual I-7000 New Features 1. Self Tuner Inside 2. Multiple Baud Rate 3. Multiple Data Format 4. Dual WatchDog Inside 5. True Distributed Control 6. High Speed & High Density