EX9017H-M is a analog input module with 8 input channels. Eight channels are differential type and individual channel configuration support.
|
|
- Silvester May
- 5 years ago
- Views:
Transcription
1 1.1 Introduction EX9017H-M is a analog input module with 8 input channels. Eight channels are differential type and individual channel configuration support. Specifications: Interface: RS-485, 2 wires Speed (bps): 1200, 2400, 4800, 9600, 19.2K, 38.4K, 115.2K Analog Input type: Differential input Support individual channel configuration Analog Channels Numbers: 8 Analog Resolution: 16/12(fast mode) bits Unit Conversion: mv, V or ma Voltage range: +/-10V,+/-5V,+/-1V,+/-500mV,+/-150mV,+/-20mA Sampling Rate :10/ 50(fast mode) Samples/Second Bandwidth : 15.7 Hz Accuracy : ±0.1% Zero Drift : 0.5µV/ C Span Drift : 25ppm/ C CMR@50/60Hz : 150dB NMR@50/60Hz : 100dB Input Impedance : 20M Ohms Current Measurement: ±20mA (with external 125 ohm resistor) Power supply: +10V to +30V 1
2 1.2 Wire connection 2
3 1.2.1 Block Diagrams Vin 7+ EEPROM Wiring diagram for the EX-9017H-M Data+ Data- +Vs GND Single Controller RS485 Interface Power Supply +5V Photo-Isolation EX9017HM ADC MUX Vin 7- Vin 6+ Vin 6- Vin 1+ Vin 1- Vin 0+ Vin Default Settings Default settings for the EX-9017H-M modules are as follows:. Module Address: 01. Protocol: Modbus RTU. Analog Input Type: type 08 (-10 ~ +10V). Baud Rate: 9600 bps. Checksum disabled. Engineering unit format. Filter set at 60Hz rejection 3
4 1.4 INIT* Mode Operation Each EX9000 module has a build-in EEPROM to store configuration information such as address, type, baudrate and other information. Sometimes, user may forget the configuration of the module. Therefore, the EX9000 have a special mode named "INIT* mode" to help user to resolve the problem. The "INIT* mode" is setting as Address=00, Budrate=9600bps, no Checksum. Originally, the INIT* mode is accessed by connecting the INIT* terminal to the GND terminal. New EX9000 modules have the INIT* switch located on the rear side of the module to allow easier access to the INIT* mode. For these modules, INIT* mode is accessed by sliding the INIT* switch to the Init position as shown below. To enable INIT* mode, please following these steps: Step1. Power off the module Step2. Connect the INIT* pin with the GND pin. (or sliding the INIT* switch to the Init* ON position) Step3. Power on Step4. Send command $002 (cr) in 9600bps to read the Configuration stored in the module's EEPROM. There are commands that require the module to be in INIT* mode. They are: 1. %AANNTTCCFF when changing the Baud Rate and checksum settings. See Section 2.1 for details. 2. $AAPN, See Section 2.14 for details. 4
5 1.5 Module Status for DIO, AIO Power On Reset or Module Watchdog Reset will let all output goto Power On Value. And the module may accept the host's command to change the output value. Host Watchdog Timeout will let all output goto Safe Value. The module's status(read by command~aa0) will be 04, and the output command will be ignored. 1.6 Dual Watchdog Operation for DIO, AIO Dual Watchdog=Module Watchdog + Host Watchdog The Module Watchdog is a hardware reset circuit to monitor the module's operating status. While working in harsh or noisy environment, the module may be down by the external signal. The circuit may let the module to work continues and never halt. The Host Watchdog is a software function to monitor the host's operating status. Its purpose is to prevent the network from communication problem or host halt. When the timeout interval expired, the module will turn all outputs to predefined Safe Value. This can prevent the controlled target from unexpected situation. The EX9000 module with Dual Watchdog may let the control system more reliable and stable. 1.7 Reset Status The Reset Status is set while the module power on or reset by module watchdog and is cleared while the command read Reset Status ($AA5) applied. This is useful for user to check the module's working status. When the Reset Status is set means the module is reset and the output may be changed to the PowerOn Value. When the Reset Status is clear means the module is not rested and the output is not changed. 5
6 1.8 Calibration(Warning: Please don't calibrate before you really understand.) Set the module of data format to which you wish to calibration first. Protocol: ASCII mode. Address: 01 Input type: which type you wish to calibration Filter: which rejection you wish to calibration Perform Zero Calibration: 1. Send the command $01501 to CH0 enable, CH1~7 disable. 2. Apply zero voltage/current to module s channel 0 (Vin0+ to Vin0-) 3. Send the command ~01E1 to enable calibration. 4. Send the command $011 to perform zero calibration. Perform Span Calibration: 1. Send the command $01502 to CH1 enable, CH0 & 2~7 disable. 2. Apply Span voltage/current to module s channel 1 Type code A 0B 0C 0D Span +10V +5V +1V +500mV +150mV +20mA 3. Send the command ~01E1 to enable calibration. 4. Send the command ~01CALS to perform span calibration. 5. Send the command #011 to check the CH0 input value is correct. If the value is over the signal, decrease the value If the value is less the signal, increase the value The value should between ~5B0000, Hexadecimal format. Note: While calibrate type of current, need connect external shunt resistor, 125ohms, 0.1% to channel1. 6
7 1.9 Configuration Tables Baud Rate Setting (CC) Code A Baud rate Sensor Type & V/I Range Setting (TT) Code Range Format +F.S. Zero -F.S. Engineer unit V ~ +10V % of F.S.R s 7FFF complement Engineer unit V ~ +5V % of F.S.R s 7FFF complement Engineer unit A -1V ~ +1V % of F.S.R s 7FFF complement Engineer unit B -500mV ~ % of F.S.R mV 2 s 7FFF complement Engineer unit C -150mV ~ % of F.S.R mV 2 s 7FFF complement Engineer unit D -20mA ~ +20mA % of F.S.R s 7FFF complement 7
8 Data Format Setting (FF) FS CS MS reserved DF Key DF MS CS FS Description Data format 00: Engineering unit 01: % of FSR (full scale range) 10: 2 s complement hexadecimal Mode setting 0: normal mode (16bit) 1: fast mode (12bit) Checksum (CRC in Modbus) setting 0: Disabled 1: Enabled Filter setting 0: 60Hz rejection 1: 50Hz rejection Note: The reserved bits should be zero. 8
9 2.0 Command set 2.1 %AANNTTCCFF Description: Set Module Configuration. Syntax: %AANNTTCCFF[CHK](cr) % a delimiter character AA address of setting/response module(00 to FF) NN TT CC FF new address for setting/response module(00 to FF) represents the type code. Type code determines the input range. If TT=FF the type of all channels keep no change. new baudrate for setting module. new data format for setting module. IF the configuration with new baudrate or new checksum setting, before using this command, the rear slide switch must be in the ON(INIT*) position. The new setting is saved in the EEPROM and will be effective after the next power-on reset. Response: Valid Command:!AA Invalid Command:?AA Example: Command: % Receive:!02 Set module address 02 to 03. Input type code=08 (-10~+10V) for all channels Baudrate=06 (9600) Dataformat=02 (2 s complement hexadecimal) 9
10 2.2 #AA Description: Read Analog Input Syntax: #AA[CHK](cr) # delimiter character AA address of reading/response module(00 to FF) Response: Valid Command: >(Data) (Data) analog input value for its format while use #AA command to EX-9018BL/9019, the data is the combination for each channel respectively. Example : Command: #04 Receive:> The module address 04 is EX-9018BL/9019. Read address 04 for getting data of all 8 channels. 10
11 2.3 #AAN Description : Read Analog Input from channel N Syntax : #AAN[CHK](cr) # delimiter character AA address of reading/response module(00 to FF) N channel to read, from 0 to 7 Response: Valid Command: >(Data) Invalid Command:?AA (Data) analog input value for its format Example : Command : #032 Receive : > Read address 03 channel 2, get data successfully. Command : #029 Receive :?02 Read address 02 channel 9, return error channel number. 11
12 2.4 $AA0 Description: Perform Span Calibration Syntax: $AA0[CHK](cr) $ delimiter character AA address of setting/response module (00 to FF) 0 command for performing zero calibration Response: Valid Command:!AA Invalid Command:?AA Example : Command : $010 Receive :!01 Perform address 01 zero calibration on channel 0, return success. Command : $020 Receive :?02 Perform address 02 zero calibration on channel 2, return not enable calibration before perform calibration command. Warning: Please don't calibrate before you really understand. 12
13 2.5 $AA1 Description: Perform Zero Calibration Syntax: $AA1[CHK](cr) $ delimiter character AA address of setting/response module (00 to FF) 1 command for performing span calibration Response: Valid Command:!AA Invalid Command:?AA Example: Command: $011 Receive:!01 Perform address 01 span calibration on channel 0, return success. Command: $021 Receive:?02 Perform address 02 span calibration on channel 2, return not enable calibration before perform calibration command. Warning: Please don't calibrate before you really understand. 13
14 2.6 $AA2 Description: Read configuration. Syntax: $AA2[CHK](cr) $ delimiter character AA address of reading/response module (00 to FF) 2 command for read configuration Response: Valid Command: Invalid Command:!AATTCCFF?AA TT CC FF type code of module baudrate code of module data format of module Example: Command: $012 Receive:! Read the configuration of module 01, input range of -2.5~+2.5V, baudrate 9600, no checksum. Note: check configuration Tables 14
15 2.7 $AA5VV Description: Set Channel Enable Syntax: $AA5VV[CHK](cr) $ delimiter character AA address of setting/response module (00 to FF) 5 command for set channel enable VV are two hexadecimal values. The values are interpreted by the module as two binary words (4-bit). The first word represents the status of channel 4~7, and the second word represents the status of channel 0~3. Value 0 means the channel is disabled, value 1 means the channel is enabled. Response: Valid Command:!AA Invalid Command:?AA Example: Command :$0152A Receive :!01 Set address 01 to enable channel 1,3,5 and disable channel 0,2,4,6,7 return success. Command : $016 Receive :!012A Read address 01 channel status, return channel 1,3,5 are enabled and channel 0,2,4,6,7 are disabled. 15
16 2.8 $AA6 Description: Read Channel Status Syntax: $AA6[CHK](cr) $ delimiter character AA address of reading/response module (00 to FF) 6 command for read channel status Response: Valid Command:!AAVV Invalid Command:?AA VV are two hexadecimal values. The values are interpreted by the module as two binary words (4-bit). The first word represents the status of channel 4~7, and the second word represents the status of channel 0~3. Value 0 means the channel is disabled, value 1 means the channel is enabled. Example: Command :$0152A Receive :!01 Set address 01 to enable channel 1,3,5 and disable channel 0,2,4,6,7 return success. Command : $016 Receive :!012A Reads Read address 01 channel status, return channel 1,3,5 are enabled and channel 0,2,4,6,7 are disabled. 16
17 2.9 $AA7CiRrr Description: Sets the type code of a channel individually. Syntax: $AA7CiRrr[CHK](cr) $ delimiter character AA address of setting/response module(00 to FF) 7C the set channel type command i channel number R the set channel type command rr channel type code Response: Valid comma nd:!aa Invalid command:?aa Example: Command: $017C3R08 Receive:!01 Sets the type code for channel 3 of module 01 to be 08 (-10~+10V) and the module returns a valid response. Command: $037C1R40 Receive:?03 Sets the type code for channel 1 of module 03 to be 40. The module returns an invalid response because the type code is invalid. 17
18 2.10 $AA8Ci Description: Reads the type code information of a channel. Syntax: $AA8Ci[CHK](cr) $ delimiter character AA address of reading/response module(00 to FF) 8C read channel type command i channel number Response: Valid command:!aacirrr Invalid command:?aa i rr channel numbers(0~7) type of channel i Example: Command: $018C0 Receive:!01C0R03 Reads the type(input range) of channel 0 of module 01 to be 03 (-10~+10V). 18
19 2.11 $AAF Description: Read Firmware Version Syntax: $AAF[CHK](cr) $ delimiter character AA address of reading/response module(00 to FF) F command for read firmware version Response: Valid command:!aa(data) Invalid command:?aa (Data) Firmware version of module Example: Command : $01F Receive :!01M6.92 Read address 01 firmware version, return version M
20 2.12 $AAM Description: Read Module Name Syntax: $AAM[CHK](cr) $ delimiter character AA address of reading/response module(00 to FF) M command for read module name Response: Valid command:!aa(data) Invalid command:?aa (Data) Name of module Example: Command : $01M Receive :!019017H-M Read address 01 module name, return name 9017H-M. 20
21 2.13 $AAP Description: Read protocol information of Module Syntax: $AAP[CHK](cr) $ delimiter character AA address of reading/response module(00 to FF) P command for read protocol information of module Response: Valid command:!aas Invalid command:?aa S The protocol supported by the module 0: the protocol set in EEPROM is Normal mode 1: the protocol set in EEPROM is ModbusRTU mode Example: Command: $01P Response:!010 Reads the communication protocol of module 01 and returns a response of 0 meaning the protocol that will be used at the next power on reset is normal mode. Command: $01P1 Response:!01 Sets the communication protocol of module 01 to Modbus RTU and returns a valid response. And the next power on reset is in ModbusRTU mode. 21
22 2.14 $AAPN Description: Set the protocol information of Module Syntax: $AAPN[CHK](cr) $ delimiter character AA address of reading/response module(00 to FF) P command for read protocol information of module N The protocol supported by the module 0: the protocol set in EEPROM is Normal mode 1: the protocol set in EEPROM is ModbusRTU mode Response: Valid command:!aa Invalid command:?aa Example: Command: $01P1 Response:!01 Sets the communication protocol of module 01 to Modbus RTU and returns a valid response. And the next power on reset is in ModbusRTU mode. 22
23 2.15 ~AAEV Description: Enable/Disable Calibration Syntax: ~AAEV[CHK](CR) ~ delimiter character AA address of setting/response module (00 to FF) E command for enable/disable calibration V 1=Enable/0=Disable calibration Response: Valid Command:!AA Invalid Command:?AA Example: Command : $011 Receive:?01 Perform address 01 zero calibration, return the command is invalid before enable calibration. Command : ~01E1 Receive:!01 Set address 01 to enable calibration, return success. Command: $011 Receive:!01 Preform address 01 zero calibration, return success. Warning: Please don't calibrate before you really understand. 23
24 2.16 ~AAO(Data) Description: Set Module Name Syntax: ~AAO(Data)[CHK](cr) ~ delimiter character AA address of setting/response module(00 to FF) O command for set module name (Data) new name for module, max 6 characters Response: Valid command:!aa Invalid command:?aa Example: Command:~01O9019HM Receive :!01 Set address 01 module name 9019HM, return success. 24
25 2.17 ~** Description: Host OK. Host send this command to all modules for send the information "Host OK" Syntax: ~**[CHK](cr) ~ delimiter character ** command for all modules Response: No response. Example: Command: ~** No response 25
26 2.18 ~AA0 Description: Read Module Host Watchdog Status. Syntax: ~AA0[CHK](cr) ~ delimiter character AA address of reading/response module(00 to FF) 0 command for read module status Response: Valid command:!aass Invalid command:?aa SS module status, 00= host watchdog is disabled & host watchdog timeout status is clear, 80= host watchdog is enabled & host watchdog timeout status is clear. 84= host watchdog is enabled & host watchdog timeout status is set. The status will store into EEPROM and only may reset by the command~aa1. SS Host watchdog Host watchdog timeout status 00 Disable Clear 80 Enable Clear 84 Enable Set 26
27 2.19 ~AA1 Description: Reset Module Host Watchdog Status. Syntax: ~AA1[CHK](cr) ~ delimiter character AA address of setting/response module(00 to FF) 1 command for reset module status Response: Valid command:!aa Invalid command:?aa 27
28 2.20 ~AA2 Description: Read Host Watchdog Timeout Value Syntax: ~AA2[CHK](cr) ~ delimiter character AA address of reading/response module(00 to FF) 2 command for read host watchdog timeout value Response: Valid command :!AAEVV Invalid command:?aa E host watchdog enable status, 1=Enable, 0=Disable VV timeout value in HEX format, each count is 0.1 second 01=0.1 second and FF=25.5 seconds 28
29 2.21 ~AA3EVV Description: Set Host Watchdog Timeout Value Syntax: ~AA3EVV[CHK](cr) ~ delimiter character AA address of setting/response module(00 to FF) 3 command for set host watchdog timeout value E 1=Enable/0=Disable host watchdog VV timeout value, from 01 to FF, each for 0.1 second Response: Valid command:!aa Invalid command:?aa Example: Command : ~010 Receive :!0100 Read address 01 modules status, return host watchdog timeout status is clear. Command : ~ Receive :!01 Set address 01 host watchdog timeout value 10.0 seconds and enable host watchdog, return success. Command : ~012 Receive :!01164 Read address 01 host watchdog timeout value, return that host watchdog is enabled, and time interval is 10.0 seconds. Command : ~** No response Reset the host watchdog timer. Wait for about 10 seconds and don't send command~**, the LED of module will go to flash. The flash LED indicates the host watchdog timeout status is set. Command : ~010 Receive :!
30 Read address 01 module status, return host watchdog timeout status is set. Command : ~012 Receive :!01064 Read address 01 host watchdog timeout value, return that host watchdog is disabled, and time interval is 10.0 seconds. Command : ~011 Receive :!01 Reset address 01 host watchdog timeout status, return success And the LED of this module stop flash. Command : ~010 Receive :!0100 Read address 01 module status, return host watchdog timeout status is clear. 30
31 2.22 ~AAM Description: Read the data format in Modbus mode Syntax: ~AAM[CHK](cr) ~ delimiter character AA address of setting/response module(00 to FF) M command for read the data format in Modbus mode Response: Valid command:!aas Invalid command:?aa S 0=Engineer unit 1=2 s complement hexadecimal Example: Command:~01M Receive :!010 Read address 01 module status, return the dataformat in modbus mode is engineer unit. 31
32 2.23 ~AAMS Description: Set the data format in Modbus mode Syntax: ~AAMV[CHK](cr) ~ delimiter character AA address of setting/response module(00 to FF) M command for set the data format in Modbus mode S 0=Engineer unit 1=2 s complement hexadecimal Response: Valid command: Invalid command:!aa?aa Example: Command:~01M1 Receive :!01 Set address 01 dataformat in modbus mode is 2 s complement hexadecimal, return success. 32
33 EX-9017H-M Modbus Quick Start 1. The default setting is MODBUS mode after Power On. 2. Sliding the INIT* switch to the Init(ON) position Init* to GND ON of rear side then Power On will enter INIT* mode (use ASCII command). 1 Normal 3. On ASCII command mode, user can set other setting like Address, Baudrate, by use ASCII command or EX-9000 utility (Please check the EX-9000 user manual). Note: If your application need with CRC check in modbus mode, please set the module to checksum(crc) enable. 4. After change the setting finish, Sliding the INIT* Init* to GND ON switch to the Normal(1) position of rear side, the new setting will be effective after the next power-on reset. 1 Normal 33
34 This function code is used to read from 1 to 8 continuous analog input channels. Request 00 Address 1Byte 1 to Function code 1Byete 0x Starting channel 2 0 to 7 for reading analog inputs Bytes Number of input Channels(N) 2Bytes 1 to 8;(Starting channel+n)<=8 for reading analog inputs Response 00 Address 1Byte 1 to Function code 1Byete 0x04 02 Byte count 1 Byte 2 x N 03~ Data of input 2 x N channels Bytes Error Response 00 Address 1Byte 1 to Function code 1Byete 0x84 Exception code 1 Byte 02:starting channel out of range 03:( starting channel+number of input channels) out of range, incorrect number of bytes received 34
35 01(0x01) Read WDT timeout status Request 00 Address 1 Byte Function code 1 Byte 0x01 02~03 Starting channel 2 Bytes 0x010D 04~05 Read WDT timeout 2 Bytes 0x0001 status Response 00 Address 1 Byte Function code 1 Byte 0x01 02 Byte count 1 Byte 1 03 Read WDT timeout status 1 Byte 0x00 The WDT timeout status is clear 0x01 The WDT timeout status is enable Error Response 00 Address 1 Byte Function code 1 Byte 0x81 02 Exception code 1 Byte Refer to the Modbus standard for more details. 35
36 03(0x03) Read WDT timeout Value Request 00 Address 1 Byte Function code 1 Byte 0x03 02~03 Starting channel 2 Bytes 0x01E8 04~05 Read WDT timeout 2 Bytes 0x0001 value Response 00 Address 1 Byte Function code 1 Byte 0x03 02 Byte count 1 Byte 2 03~ Read WDT timeout value 1 Byte 0x0000~0x00FF WDT timeout value, 0~255, in 0.1 second Error Response 00 Address 1 Byte Function code 1 Byte 0x83 02 Exception code 1 Byte Refer to the Modbus standard for more details. 36
37 03(0x03) Send Host OK Request 00 Address 1 Byte Function code 1 Byte 0x03 02~03 Starting channel 2 Bytes 0x ~05 Send Host OK 2 Bytes 0x0000 No Response 04(0x04) Send Host OK Request 00 Address 1 Byte Function code 1 Byte 0x04 02~03 Starting channel 2 Bytes 0x ~05 Send Host OK 2 Bytes 0x0000 No Response 37
38 05(0x05) Set WDT timeout /Clear WDT timeout status Request 00 Address 1 Byte Function code 1 Byte 0x05 02~03 WDT timeout 2 Bytes 0x0104 Set WDT timeout enable/disable 0x010D Clear WDT timeout status 04~05 WDT timeout 2 Bytes 0xFF00 for WDT timeout enable 0x0000 for WDT timeout disable 0xFF00 for Clear WDT timeout status Response 00 Address 1 Byte Function code 1 Byte 0x05 02~03 WDT timeout 2 Bytes The value is the same as byte 02 and 03 of the Request 04~05 WDT timeout 2 Bytes The value is the same as byte 04 and 05 of the Request Error Response 00 Address 1 Byte Function code 1 Byte 0x85 02 Exception code 1 Byte Refer to the Modbus standard for more details. 38
39 06(0x06) Set WDT timeout Value Request 00 Address 1 Byte Function code 1 Byte 0x06 02~03 Starting channel 2 Bytes 0x01E8 04~05 WDT timeout value 2 Bytes 0x0000~0x00FF WDT timeout value, 0~255, in 0.1 second Response 00 Address 1 Byte Function code 1 Byte 0x06 02~03 WDT timeout value 2 Bytes The value is the same as byte 02 and 03 of the Request 04~05 WDT timeout value 2 Bytes The value is the same as byte 04 and 05 of the Request Error Response 00 Address 1 Byte Function code 1 Byte 0x86 02 Exception code 1 Byte Refer to the Modbus standard for more details. 39
40 Modbus Mapping Table: Input register addresses are available for MODBUS function code 0x04 Address Hex Channel Content Attribute H 0 Analog input Value Read H 1 Analog input Value Read H 2 Analog input Value Read H 3 Analog input Value Read H 4 Analog input Value Read H 5 Analog input Value Read H 6 Analog input Value Read H 7 Analog input Value Read Holding register addresses are available for MODBUS function code 0x03, 0x06, 0x10 Address Hex Channel Content Attribute H 0 Analog input Value Read H 1 Analog input Value Read H 2 Analog input Value Read H 3 Analog input Value Read H 4 Analog input Value Read H 5 Analog input Value Read H 6 Analog input Value Read H 7 Analog input Value Read 40
41 MODBUS Engineering Data Format Table Type Code Input Type Min. Max. Formula 08-10V ~ +10V Volt=(Modbus data)/ V ~ +5mV Volt=(Modbus data)/1000 0A -1V ~ +1V Volt=(Modbus data)/ B -500mV ~ +500mV Volt=(Modbus data)/10 0C --150mV ~ +150mV Volt=(Modbus data)/100 0D --20mA ~ +20mA Current=(Modbus data)/1000 Example: Assume type of channel is +/-10V and MODBUS data=0x2030(hex)=8240(dec) The voltage of channel is 8240/1000=8.24V Example: Assume type of channel is +/-500mV and MODBUS data=0xef1b(hex)=-4325(dec) The voltage of channel is -4235/10=423.5mV Example: Assume type of channel is +/-20mA and MODBUS data=0x3b84(hex)=15236(dec) The current of channel is 15236/1000=15.236mA MODBUS Hex 2 s complement Data Format Table Type Code Input Type Min. Max. Formula 08-10V ~ +10V FFF Volt=(MODBUS data *10)/ V ~ +5mV FFF Volt=(MODBUS data *5)/ A -1V ~ +1V FFF Volt=(MODBUS data *1)/ B -500mV ~ +500mV FFF Volt=(MODBUS data *500)/ C --150mV ~ +150mV FFF Volt=(MODBUS data *150)/ D --20mA ~ +20mA FFF Current=(MODBUS data *20)/32767 Example: Assume type of channel is +/-10V and MODBUS data=0x2030(hex)=8240(dec) The voltage of channel is (8240*10)/32767=2.514V Example: Assume type of channel 1 is +/-500mV and MODBUS data=0xef1b(hex)=-4325(dec) The voltage of channel is (-4235*500)/32767= mV Example: Assume type of channel 1 is +/-20mA and MODBUS data=0x3b84(hex)=15236(dec) The current of channel is (15236*20)/32767=9.299mA 41
1. Introduction. Note: For EX9050HD the (INIT*) switch located on the rear side of the module.
1. Introduction EX-9050HD/HD-M/ provides 8 non-isolated digital output(sink) channels and 8 non-isolated digital input(source)channels All input/output channels are single-ended with common ground (See
More information8013,8013D, 8033 User Manual
8013,8013D, 8033 User Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning
More information8017, 8018, 8019, 8017, M-8018, M-8019 Series User's Manual
8017, 8018, 8019, 8017, M-8018, M-8019 Series User's Manual Warranty All products manufactured by SuperLogics are under warranty regarding defective materials for a period of one year from the date of
More informationI-7017, I-7018, I-7019, M-7017, M-7018 and M-7019 Series User Manual
I-7017, I-7018, I-7019, M-7017, M-7018 and M-7019 Series User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date
More information8000 DIO Manual Warranty Warning Copyright Trademark
8000 DIO Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning SuperLogics
More informationi-7005 and M-7005 User s Manual
i-7005 and M-7005 User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationSuperLogics 8000 Series Analog Input Modules
SuperLogics 8000 Series Analog Input Modules SuperLogics 8000 Series of compact remote data acquisition modules provides intelligent signal conditioning, analog I/O, and digital I/O. Through a cost-effective
More informationZB-2024 Series User Manual
ZB-2024 Series User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser. Warning
More informationI-7000 DIO Manual Warranty Warning Copyright Trademark
I-7000 DIO Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning ICP DAS assume
More informationI-7021, I-7022, I-7024, M-7022, M-7024 and M-7028 Series User Manual
I-7021, I-7022, I-7024, M-7022, M-7024 and M-7028 Series User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date
More informationTRP-C68. 8-Channel Analog Input to Digital Output Isolated Module Support ASCII and Modbus RTU protocol USER S MANUAL. June Rev 1.
TRP-C68 8-Channel Analog Input to Digital Output Isolated Module Support ASCII and Modbus RTU protocol USER S MANUAL June. 2007 Rev 1.0 Trycom Technology Co.,Ltd 1F, No.2-11,Sihu street,yingge Township,
More informationCB-7000 DIO User s Manual
CB-7000 DIO User s Manual CB-7041/7041D CB-7042/7042D CB-7043/7043D CB-7044/7044D CB-7050/7050D CB-7052/7052D CB-7053/7053D CB-7060/7060D CB-7063/7063D/A/AD/B/BD CB-7065/7065D/A/AD/B/BD CB-7066/7066D CB-7067/7067D
More informationJSD81 series products are based on SCM's intelligent monitoring and control system, users set the calibration value,
8-Channel Analog Signals to RS485/232 Converter(A/D Converter JSD81 series) Features: 8-CH analog signal acquisition/isolation,rs-485/232 output 24-bit AD converter, testing accuracy>0.05% Can Program
More informationTRP-C68. 8-Channel Analog Input to Digital Output Isolated Module Support ASCII and Modbus RTU protocol USER S MANUAL. Dec Rev 1.
TRP-C68 8-Channel Analog Input to Digital Output Isolated Module Support ASCII and Modbus RTU protocol USER S MANUAL Dec. 2010. Rev 1.2 Trycom Technology Co.,Ltd 1F, No.2-11,Sihu street,yingge Township,
More informationI-7000 and M-7000 DIO User Manual
I-7000 and M-7000 DIO User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationI-7000 and M-7000 DIO User Manual
I-7000 and M-7000 DIO User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationRTD Temperature acquisition converter WJ25
8-CH Thermocouple Signal to RS485/232 Acquisition Converter (WJ27 series 24Bits A/D Converter, data acquisition) Features: >> Eight channels thermocouple signal acquisition, isolated converter RS-485/232
More informationSignal Isolators & Conditioners
WJ21 series Analog Signal to RS485/232 Converter (A/D Converter) Features: >> Analog signal acquisition, isolated RS-485/232 output >> 12-bit AD converter, testing accuracy>0.1% >> Can Program and calibrate
More informationI-7083/7083D/7083B/7083BD
I-7083/7083D/7083B/7083BD User s Manual I-7000 New Features 1. Self Tuner Inside 2. Multiple Baud Rate 3. Multiple Data Format 4. Dual WatchDog Inside 5. True Distributed Control 6. High Speed & High Density
More informationAnalog signal to RS485 or RS232 Converter, A/D Converter
Analog signal to RS485 or RS232 Converter, A/D Converter Features: Analog signal acquisition, isolated RS-485/232 output 12-bit AD converter, testing accuracy>0.1% Can be remotely reconfigured for modules
More informationSignal Isolators & Conditioners
Analog Signal to RS485/232 Converter Signal Isolators & Conditioners (WJ21 series A/D Converter) Features: >> Analog signal acquisition, isolated RS-485/232 output >> 12-bit AD converter, testing accuracy>0.1%
More informationOMR-6021 Analog Output OMR Channel Analog Output
OMR-6021 Analog Output OMR-6024 4-Channel Analog Output Contents 1. INTRODUCTION...1-1 1. 1. ABOUT THE OMR ANALOG OUTPUT MODULES 1-1 1. 2. OVERVIEW OF OMR-6021 1-1 1. 3. OVERVIEW OF OMR-6024 1-4 2. INITIALIZATION
More informationAmazing Electronic (HK) Limited Serial RS232/RS485 to analog signal converter
DAM-DA D/A converter Datasheet Overview: DAM module is a new generation data acquisition and control system based on modular embedded systems. Adopting standard DIN35 rail mounting package is simple, flexible
More informationTRP-C channel Digital Input Isolated RS485 Module, Support ASCII and Modbus Protocol. User s Manual. Printed APR Rev 1.
TRP-C26 16-channel Digital Input Isolated RS485 Module, Support ASCII and Modbus Protocol. User s Manual Printed APR. 2007 Rev 1.0 Trycom Technology Co.,Ltd 1F, No.2-11,Sihu street,yingge Township, Taipei,
More informationProdukt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt
Produkt-Datenblatt Technische Daten, Spezifikationen Kontakt Technischer und kaufmännischer Vertrieb, Preisauskünfte, Angebote, Test-Geräte, Beratung vor Ort: Tel: (0 81 41) 52 71-0 FAX: (0 81 41) 52 71-129
More informationSignal Isolators & Conditioners
RS485/232 to Analog Signal Converter Signal Isolators & Conditioners (D/A Converter,WJ31 series) Features: >> RS-485/232 interface, isolation convert standard analog signal output >> Analog signal output
More information4.6 Digital I/O and Relay Output Module Command
4050, 4052, 4053, 4060 Chapter 4 4.6 Digital I/O and Relay Output Module Command Command Syntax Command % AANNTTCCFF C onfiguration Sets the address, input range, baud rate, and/or checksum status, to
More informationTRP-C28. 4-channel isolated digital input and 4-channel power relay output RS485 module, Support ASCII and Modbus Protocol.
TRP-C28 4-channel isolated digital input and 4-channel power relay output RS485 module, Support ASCII and Modbus Protocol. User s Manual Printed NOV. 2007 Rev 1.0 Trycom Technology Co.,Ltd 1F, No.2-11,Sihu
More informationProdukt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt
Produkt-Datenblatt Technische Daten, Spezifikationen Kontakt Technischer und kaufmännischer Vertrieb, Preisauskünfte, Angebote, Test-Geräte, Beratung vor Ort: Tel: (0 81 41) 52 71-0 FAX: (0 81 41) 52 71-129
More informationNuDAM. ND-6021 Analog Output ND Channel Analog Output
NuDAM ND-6021 Analog Output ND-6024 4-Channel Analog Output @Copyright 1996 ADLink Technology Inc. All Rights Reserved. Manual first edition: January 7, 1996 Manual Rev. 2.0: December 5, 1997 Manual Rev.
More informationOMR-6011/D OMR-6014D OMR-6012/D OMR-6017 OMR-6013 OMR Analog Input Modules
OMR-6011/D OMR-6014D OMR-6012/D OMR-6017 OMR-6013 OMR-6018 Analog Input Modules Contents 1 Introduction... 1-1 1. 1. ABOUT THE OMR ANALOG INPUT MODULES...1-1 1. 2. OVERVIEW OF OMR-6011/D...1-1 1. 3. OVERVIEW
More informationNuDAM-6011/ NuDAM-6014D NuDAM-6012/D NuDAM-6017 NuDAM-6013/ NuDAM-6018 Analog Input Modules User s Guide
NuDAM-6011/ NuDAM-6014D NuDAM-6012/D NuDAM-6017 NuDAM-6013/ NuDAM-6018 Analog Input Modules User s Guide Copyright 1996~2001 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 5.15: October 2, 2001
More informationBrainboxes Ethernet to Analogue IO
Print Date: 06/05/15 Brainboxes Ethernet to Analogue IO Brainboxes Limited, 18 Hurricane Drive, Liverpool International Business Park, Speke, Liverpool, Merseyside, L24 8RL Tel: +44 (0)151 220 2500 Fax:
More informationThe I-7530A RS-232/485/422 to CAN Converter
The I-7530A RS-232/485/422 to CAN Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery
More informationTRP-C29. 8-channel isolated digital input and 8-channel isolated digital output(o.c) RS485 module, Support ASCII and Modbus Protocol.
TRP-C29 8-channel isolated digital input and 8-channel isolated digital output(o.c) RS485 module, Support ASCII and Modbus Protocol. User s Manual Printed Sep. 2013 Rev 1.3 Trycom Technology Co.,Ltd No.35,
More informationInput Channels: 4 differential or four single-ended. Address / Baud rate / range configurable by the user
DAM-Series User Manual Amazing Electronic (HK) Limited User s Manual Overview: DAM module is a new generation data acquisition and control system based on modular embedded systems. Adopting standard DIN35
More informationISO AD A08 8-channel isolated 4-20mA Signal Acquisition Module ⅠProduct Introduction
ISO AD A08 8-channel isolated 4-20mA Signal Acquisition Module ⅠProduct Introduction Features: 8-ch 4-20mA signal acquisition, signal between channel to channel is isolated RS-485/232 output can adjust
More informationTechnical specification
Technical specification EXPERT i/o extension modules Version 01.00.00 23-02-2017 This manual contains technical documentation which allows for easy installation and use of the i/o extension module product
More informationEX952N Series (Addressable RS422/485 to RS232 converter)
EX952N Series (Addressable RS422/485 to RS232 converter) EX952N Quick Manual Introduction EX952N is an Addressable RS422/485 to RS232 converter that it is designed to connect RS422/485 devises to an RS232
More informationAnalog Input Modules User s Guide
ND-6021 & ND-6024 Analog Input Modules User s Guide Copyright 1996~2001 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 4.00: June 5,2001 The information in this document is subject to change
More informationWarranty. Warning. Copyright. Contact Us
M-6026U-32 16-channel Universal Input and 16-channel Universal Output Version: 1.0.0 Date: Dec. 2017 Edited by Horse Chien M-6026U-32 User Manual Version 1.0.0 Dec. 2017-1 - Warranty All products manufactured
More informationThe I-7530A-MR Modbus RTU to CAN Converter
The I-7530A-MR Modbus RTU to CAN Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery
More informationET-7000 series Ethernet Remote I/O Module
ET-7000 series Ethernet Remote I/O Module User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, starting from the date of
More informationWolf series Remote IO Modules User s Manual
Wolf series Remote IO Modules User s Manual Copyright The description, exemplary and software applied to Wolf Series Module are the copyright of Advanio Co., Ltd. Any modification, reproduction, duplication,
More informationGetting Started with your D3000M Series Module
Getting Started with your D3000M Series Module This document contains step-by-step instructions to quickly connect and communicate with your D3000M modules. The modules require a one-time configuration
More informationTRP-C28 User s Manual
Introductions Features TRP-C28 provides 4 optical isolated digital input channels that allow you to input the logic signal from to 3V DC and 4 power relays output. All channel features screw terminals
More information4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM102(1739) For 4511 devices from ser. no:
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM102(1739) For 4511 devices from ser. no: 141590001 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 4511 Supported
More informationSignal Isolators & Conditioners
8-ch DI Switch Signal to RS485/232 Converters (WJ62 Series) Features: >> Eight channels switch signal acquisition,isolated RS-485/232 output >> Each input channel adopts optical isolation >> Can read level
More informationI-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS
I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog
More informationTRP-C24 User's Manual
Introductions Features The TRP-C24, an RS-485 isolated open collector output module, provides 16 digital outputs channels. Each channel features screw terminals for the convenience connection of field
More informationADAM Data Acquisition Modules User's Manual
ADAM 4000 Data Acquisition Modules User's Manual ADAM 4000 Series Data Acquisition Modules User s Manual Copyright Notice This document is copyrighted, 1997, by Advantech Co., Ltd. All rights are reserved.
More information8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user
8 Channel Analog Input Module Datasheet User s Manual Overview: DAM module is a new generation data acquisition and control system based on modular embedded systems. Adopting standard DIN35 rail mounting
More informationModBUS Protocol for SMART 3
ModBUS Protocol for SMART 3 The communication between Smart 3 unit and a CPU is made by means of the ModBUS RTU protocol. Please refer to the specific documentation of the ModBUS RTU protocol for implementing
More informationI-7080, I-7080B. User Manual
I-7080, I-7080B User Manual I-7000 New Features 1. Self Tuner Inside 2. Multiple Baud Rate 3. Multiple Data Format 4. Dual WatchDog Inside 5. True Distributed Control 6. High Speed & High Density I/O Your
More information8520/8520R. User Manual
/R User Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Disclaimer SuperLogics
More informationRS232-ADC16/24 Manual
RS232-ADC16/24 Manual Version 1.11 Copyright taskit GmbH 2009 www.taskit.de Page 1/22 Table of contents 1 Features...3 2 Introduction...3 3 Bringing into service...4 4 Application Sample...5 5 Frame layout...6
More informationGPS-721 User Manual v2.0
GPS-721 User Manual v2.0 High-quality Industrial Data Acquisition and Control Products 1/98 V2.0, Oct. 2010 Warranty All products manufactured by ICP DAS are warranted against defective materials for a
More informationSpecifications minilab 1008
Specifications minilab 1008 Document Revision 1.3, May, 2004 Copyright 2004, Measurement Computing Corporation Specifications Typical for 25 C unless otherwise specified. Analog Input Section A/D converter
More informationIt is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.
MCD Modbus Module Instructions Important User Information INSTALLATION INSTRUCTIONS: MCD MODBUS MODULE Order Code: 175G9000 1. Important User Information Observe all necessary safety precautions when controlling
More informationAIAO U CompactPCI Analog I/O Card. User Manual. 13 Altalef St. Yehud, Israel Tel: 972 (3) Fax: 972 (3)
AIAO-0700 3U CompactPCI Analog I/O Card User Manual 13 Altalef St. Yehud, Israel 56216 Tel: 972 (3) 632-0533 Fax: 972 (3) 632-0458 www.tenta.com 919 Kifer Road Sunnyvale, CA 94086 USA Tel: (408) 328-1370
More informationUser s Guide OME-ET-7000 AND OME-PET-7000 SERIES. Ethernet I/O Modules
egister Table User s Guide Shop online at omega.com e-mail info@omega.com For latest product manuals omegamanual.info OME-ET-7000 AND OME-PET-7000 SEIES Ethernet I/O Modules OMEGAnet On-Line Service omega.com
More information4511 MODBUS RTU. Configuration Manual. Solenoid / alarm driver. No. 9203MCM100(1328)
4511 MODBUS RTU Configuration Manual Solenoid / alarm driver 9203MCM100(1328) 9203 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and factory
More informationSignal Isolators & Conditioners
4-ch DI 4-ch Relay Output, RS485/232 Remote Acquisition I/O (WJ70 Series) Features: >> Four switch input, four relay output >> Can read input level status via the RS-485/232 interface >> Can set output
More informationD7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES
11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet
More informationUSB-1208LS Specifications
Specifications Document Revision 1.1, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.
More informationPAS 9737/AI-SMT ENGINEERING SPECIFICATION
Document PAS54 Spec Revision C (7/3/8) PAS 9737/AI-SMT ENGINEERING SPECIFICATION 64 CHANNEL, 6 BIT VME ANALOG INPUT CARD PCB Revision D (7/3/8) Additional copies of this manual or other Precision Analog
More informationHRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1
TM HRT-710 User s Manual Version 1.23 HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of
More informationRS-485 I/O Modules: ADAM-4000
RS-485 I/O Modules: ADAM-4000 23 ADAM-4000 Series Overview ADAM-4000 Series Remote Data Acquisition and Control Modules Overview 23-2 and Controller Module Selection Guide 23-4 I/O Module Selection Guide
More informationFP-RTD-122. Introduction CALIBRATION PROCEDURE. Version 2.0
CALIBRATION PROCEDURE FP-RTD-122 Version 2.0 Introduction This document contains step-by-step instructions for calibrating the National Instruments FP-RTD-122 module. The procedure contains the following
More informationTRP-C29U. 8-channel isolated digital input and 8-channel isolated digital output(o.c) USB serial interface module, Support ASCII and Modbus Protocol.
TRP-C29U 8-channel isolated digital input and 8-channel isolated digital output(o.c) USB serial interface module, Support ASCII and Modbus Protocol. User s Manual Printed Sep. 2014 Rev 1.2 Trycom Technology
More informationUser Manual ADAM 4000 Series. Data Acquisition Modules
User Manual ADAM 4000 Series Data Acquisition Modules Copyright The documentation and the software included with this product are copyrighted 2018 by Advantech Co., Ltd. All rights are reserved. Advantech
More informationTechnical Manual for RT-EX-9017
Technical Manual for RT-EX-9017 Version 2.01 8 x Analog Input (16 bit) Introduction The EX9017 MODBUS I/O Expansion module is a high-quality and low-cost add-on data acquisition device that allows expanding
More informationWHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System
WHERE THE FUTURE MEETS THE PRESENT Datascan solo Network Based Data Acquisition System CONTENTS INTRODUCTION 1 ANALOG INPUT/OUTPUT MODULES &3 DIGITAL INPUT/OUTPUT MODULES PRODUCT FEATURES &5 NETWORK CONTROLLERS,
More informationHART 710. User s Manual Version HART-710 User Manual (Version 1.00, July/2010) PAGE: 1
TM HART 710 User s Manual Version 1.00 HART-710 User Manual (Version 1.00, July/2010) PAGE: 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period
More information1. Implemented CM11 protocol
1. Implemented CM11 protocol 1.1. Housecodes and Device Codes. The housecodes and device codes range from A to P and 1 to 16 respectively although they do not follow a binary sequence. The encoding format
More informationRev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual
Rev. 2.93 TG100 User Manual The TG100 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life than sensors
More informationD1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES
D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;
More informationRS485 MODBUS Module 8AO
Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationCAN OPEN DP404 Digital Output
CAN OPEN DP404 Digital Output Operating Handbook code 85191A Edit. 02-02-2012-ENG Summary 1 Introduction pag. 1 2 Electrical Connections pag. 3 3 Using the transducer pag. 4 4 CAN OPEN Protocol pag. 6
More informationCaMate Series User s Manual
CaMate Series User s Manual 2017/11/17 Rev0.1 1. Introduction... 4 1.1 Configuration & Control... 4 2. Windows Application Software... 6 2.1 Configuration/Status Page... 9 2.1.1 Apply change... 9 2.1.2
More informationNuDAM-6050 NuDAM-6052 NuDAM-6053 NuDAM-6054 NuDAM-6056 NuDAM-6058 NuDAM-6060 NuDAM Digital I/O Modules
NuDAM-6050 NuDAM-6052 NuDAM-6053 NuDAM-6054 NuDAM-6056 NuDAM-6058 NuDAM-6060 NuDAM-6063 Digital I/O Modules Copyright 1995~2001 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 3.51: March 27, 2001
More informationOptidrive VTC Modbus RTU Register Map
Application Note AN-VTC- 39 Optidrive VTC Modbus RTU Register Map Author: Ning Xu, Invertek Drives Ltd Revision: 2.21 6 September 2006 General This document details the Modbus RTU memory mapping implemented
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationThe UART to CAN Bus Converter
The UART to CAN Bus Converter (I-7530, I-7530T, I-7530-FT, I-7530A, I-7565, tm-7530) User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More information4511 MODBUS RTU. Configuration Manual. Pulse isolator. No. 9202MCM101(1707) For 4511 devices from ser. no:
4511 MODBUS RTU Configuration Manual Pulse isolator No. 9202MCM101(1707) For 4511 devices from ser. no: 141590001 9202 CONTENTS Introduction...3 Modbus basics...3 Modbus RTU...3 4511 Supported Modbus Function
More informationUSB-BASED 8-CHANNEL DATA ACQUISITION MODULE
DLP-IO8-G *LEAD-FREE* USB-BASED 8-CHANNEL DATA ACQUISITION MODULE Features: 8 Channels: Digital I/O, Analog In, Temperature USB Port Powered USB 1.1 and 2.0 Compatible Interface Small Footprint; Easily
More informationFeatures and Benefits. Certifications
iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters
More informationSmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic
MAN0842-02 DIM610 PAGE 1 of 6 SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic 1 SPECIFICATIONS Number of Channels Input Ranges DIM610 12 PLC Update Rate 12/24 VDC Terminal Type DIM610
More informationConnecting M-7000 Series I/O Modules
Chapter 21. Connecting M-7000 Series I/O Modules ISaGRAF controllers support M-7000 remote I/O since below driver version. Controller Driver version W-8037 / 8337 / 8737 / 8036 / 8336 / 8736 3.32B (better
More informationPACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC
January 214 MODULE K USER SUPPLY IC694ALG442 I1 I2 I3 I4 Q1 Q2 PACSystems* RX3i and Series 9*-3 IC694ALG442-CC and IC693ALG442-EC Analog Module, 4 Inputs/2 Outputs, Current/Voltage Analog Current/Voltage
More informationEthernet Remote I/O Modules. OME-ET-7000/ OME-PET-7000 Series. Features
Ethernet Remote I/O Modules OMEET7000/ OMEPET7000 Series U MultiFunction Web Based Ethernet I/O Modules Models Available For Thermocouple, RTD, Analog Voltage and Current Input U BuiltIn Web Server for
More informationMasibus Automation And Instrumentation Pvt. Ltd.
Operator s Manual DIGITAL CONTROLLER 5006H Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationDXp-10 and DXp-15 Weight Transmitter
Precision Force and Weight Measurement Technologies DXp-10 and DXp-15 Weight Transmitter Applica pplications: Inventory Weighing Process Weighing Web Tension Measurement Product Description l Microprocessor
More informationioselect Z-NET Z-SG Bridge Input Isolating I/O Module
-wire Bridge Connection Excitation for to 30 Ω Load Cells 00 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS8 Modbus RTU Superior Flexible Power:
More informationLAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and
More informationWeeder Technologies. 90-A Beal Pkwy NW, Fort Walton Beach, FL
eeder Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com 850-863-5723 Analog Input Module This product is Obsolete due to the main A/D chip which is no longer being manufactured.
More informationEmbedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.
Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4
More informationSpecifications USB-1408FS
Document Revision 1.1, May, 2006 Copyright 2006, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design. Analog input Table
More information