1 DRC & Series DRC 4 Friendship Drive, Magnolia, TX 7755 Tel.: Fax:

2 DRC GENERAL FEATURES STANDARD FEATURES Easily configured using software or hand held interface LED indication of power, output current and fault status Compact DIN-rail mount housing Multiple modes for single and dual coil applications Input options include -0V to 0V, 0 to 0mA Programmable enable input All input and output limits are independently adjustable Adjustable current limited output with short circuit protection 0 and -0 volt references for potentiometer/ joystick controls Adjustable ramp up and ramp down rates Selectable dither frequency up to 000 Hz Microprocessor controlled for consistent, reliable performance Shown: DRC4-V- GENERAL SPECIFICATIONS STANDARD ORKING CONDITIONS Supply Voltage...9 to VDC Supply Current...lSOL 50 ma Output Current...DRC*-V- =.A max. DRC*-V-5 =.5A max. Solenoid Resistance... Ω min. Reference Voltages...0V, 0 ma Dither Settings...0, 50, 75, 00, 5, 50, 75, 00, 5, 50, 75, 00, 000 Hz Analog Input Range...DRC*-V-* = -0V to 0V Analog Input Impedance...DRC*-V-* = 8k Ω Operating Temperature Range...-4 o F to 58 o F (-0 o to 70 o C) Enclosure...Polyamide Dimensions...mm = 7.5 x 4.5 H x 09.4 D inches = 0.69 x 4.50 H x 4.0 D 4 Friendship Drive, Magnolia, TX 7755 Tel.: Fax:

3 DRC PHYSICAL DESCRIPTION The DRC is shown at the right. There are five indicator lamps labeled PR and OUT through OUT4 (for the four channel controller). The PR lamp will light green whenever power is applied to the unit and is within the specified voltage range. Under normal operation the OUTx lights will provide an indication of the current being supplied to the solenoid output for a given channel. The lights will be yellow and the brightness will vary with the output current. In the case of a fault the light will flash red with a flash code corresponding to the type of fault for that channel. Communication with the DRC takes place through the USB port. The port allows for configuration and monitoring of the operating parameters. Note: hen connected to a PC, the DR controller will be recognized as a USB device with or without power applied to the controller. However, to configure the controller it must be powered. APPLICATIONS DRC- V-* (Single Solenoid Joystick Control) The DRC can be controlled with a joystick or potentiometer as shown. The recommended potentiometer value is 0k Ω. Mode may be used rather than Mode if the enable is not used. Dither and Output settings will vary depending on the valve and application. NEG POS J 9 to VDC 4 AMP VALVE EMERGENCY STOP ENABLE C JOYSTICK J DRC- V-* (Double Solenoid Joystick) The DRC can be setup to drive a double solenoid valve using one command as shown in the following diagram. If enable is not used, C Mode shoul be set to and C Mode to. The minimum and maximum input parameters for the two channels must be set such that both outputs will not be active with the same input signal. The settings do not have to be the same or mirrored between the two channels as shown in the example though in many cases they will be. Dither and Output settings will vary depending on the valve and application. NEG POS 9 to VDC J 4 AMP 4 EMERGENCY STOP VALVE ENABLE C JOYSTICK J 4 Friendship Drive, Magnolia, TX 7755 Tel.: Fax:

4 DRC APPLICATIONS continued DRC4- V-* (Double/ Single/ Single Solenoid) NEG POS The following example shows a DRC setup to drive a double solenoid valve and single solenoid valves using three joysticks for command inputs. Dither and Output settings will vary depending on the valves and the application. J J 9 to VDC 4 AMP VALVE VALVE EMERGENCY STOP 4 ENABLE JOYSTICK C JOYSTICK C JOYSTICK C J J6 IRING Terminal functions are listed in the table below. J6 DRC4 USB PR OUT OUT OUT OUT4 DRC4-V- S/N xxxxxx J J J Terminal J- J- J- J- J- J- J- J- J J6- J6- J6- Function V Supply Supply Input Output Ch. Output Ch. Output Ch. Output Ch. 4-0V Reference 0V Reference Command Input Ch. Command Input Ch. Command Input Ch. d Input Ch.4 VALVE ORDERING INFORMATION ORDERING EXAMPLE DRC - V - DRC Series V = -0V to 0V input = Channel = Channel 4 = 4 Channel =.A output 5 =.5A output 4 Friendship Drive, Magnolia, TX 7755 Tel.: Fax:

5 GENERAL FEATURES STANDARD FEATURES Easily configured using software or hand held interface LED indication of status and output current Permanently sealed, standard DIN 4650 Form A connector body Selectable dither frequency up to 00 Hz Adjustable current limited output with short circuit protection 5 volt reference for potentiometer/ joystick controls Multiple modes for analog or -speed control Programmable enable input All input and output limits are independently adjustable Adjustable ramp up and ramp down times Pre-wired 8 AG PVC cable Microprocessor controlled for consistent, reliable performance Shown: -CV-A-5F GENERAL SPECIFICATIONS STANDARD ORKING CONDITIONS Supply Voltage...9 to 8 VDC Supply Current...lSOL 0 ma Output Current...-CV-A =.A max. -CV-5A =.5A max. Solenoid Resistance... Ωmin. Reference ma Dither Settings...Off, 0,, 8, 4, 50, 60, 75, 00, 50, 00 Hz Analog Input Range...-CV = 0 to 0V Analog Input Impedance...0kΩ Operating Temperature Range...-4 o F to 58 o F (-0 o to 70 o C) Enclosure...Glass filled Nylon 4 Friendship Drive, Magnolia, TX 7755 Tel.: Fax:

6 PHYSICAL DESCRIPTION The is shown at the right. There are two indicator lamps labeled STATUS and OUTPUT. The STATUS lamp will light green whenever power is applied to the unit and is within the specified voltage range. The STATUS light will flash red when a fault has occurred. The type of fault is indicated by the number of successive flashes. It will continue to flash until the command signal has been removed to clear the fault. The yellow lamp labeled OUTPUT provides an indication of the current being supplied to the solenoid outputs. Communication with the takes place through an infrared interface port. The port allows for configuration and monitoring of the operating parameters. The infrared adapter clips onto the aligning with the notches in the sides. IRING ire functions are listed in the table below. Folowing the table are wiring examples for various modes of operation. 9-8 VDC Terminal BRON E BLACK TE GRN/YEL Command Function V Supply Supply Command Input Input 5V Reference* Connector Ground Single Solenoid Joystick Control The can be controlled with a joystick or potentiometer as shown. This configuration uses Mode with the signal or Mode with no line. Single Solenoid -Speed Control The can be configured for -speed mode as shown. In this arrangement the signal allows minimum output and the Command signal allows maximum output. This configuration corresponds to Mode 5. Single Solenoid -Speed Control The can be configured for -speed mode as shown. In this arrangement the signal allows maximum output and the Command signal limits output to the minimum setting. This configuration corresponds to Mode VDC Slow Down *NOTE: If the 5V Reference is not used it must be isolated to prevent shorting to other wires. Failure to do so can result in damage to the controller. 4 Friendship Drive, Magnolia, TX 7755 Tel.: Fax:

7 IRING continued Single Solenoid PLC Control The can be controlled with PLC as shown. This configuration uses Mode with the signal or Mode with no line. 9-8 VDC Command Double Solenoid Two s can be driven by one signal for double solenoid operation as shown in the following diagram. One should be set to Mode or while the other is set Mode or 4. The minimum input parameters for the two should be set such that both units will not be active with the same input signal. *NOTE: Loss of Command signal in his configuration will result in maximum output to one solenoid. Care must be taken to avoid injury or damage in the event of a signal failure! Two s can be driven by one signal for double solenoid operation as shown in the following diagram. This configuration uses a selector switch to determine which solenoid is activate and a single potentiometer to determine output level. This configuration corresponds to Mode or Mode. 9-8 VDC Fast ORDERING INFORMATION ORDERING EXAMPLE - CV - A - 0F Series =.A output 5 =.5A output CV = 0 to 0V input 0F = 0 ft. cord 5F = 5 ft. cord 4 Friendship Drive, Magnolia, TX 7755 Tel.: Fax:

Digital Proportional Valve Amplifier

Digital Proportional Valve Amplifier Digital Proportional Valve Amplifier The Amplifier is a compact, low profile DIN mounted controller for use with proportional solenoid valves. The provides current to a valve coil in proportion to an input

More information

P/N: AX Distribute your control functions directly onto the valve.

P/N: AX Distribute your control functions directly onto the valve. TECHNICAL DATASHEET #TDAX022311 Dual Plug-In Valve Controller, CANopen 2-2.5A Outputs Programmable Distribute your control functions directly onto the valve. P/N: AX022311 Features: Configurable for 1

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

Power Amplifiers for PVH-EDC Pumps

Power Amplifiers for PVH-EDC Pumps Vickers Accessories Power Amplifiers for PVH-EDC Pumps EEA-EDC-436-A*-32 Design A1 - For use with PVH57 & 74 A2 - For use with PVH98 A3 - For use with PVH131 Panel Display General Description These amplifiers

More information

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

Installation Manual Series PQ-L. Electronic Module.  Bulletin /UK Bulletin 5715-571 /UK Installation Manual Electronic Module Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+) 2131-513-0 Fax: (+) 2131-513-230 www.parker.com Copyright Ó 2000, Note This document and other

More information

RPS-401A, RPS-426A Self-Contained Ultrasonic Sensor

RPS-401A, RPS-426A Self-Contained Ultrasonic Sensor Features Adjustable Zero & Span Sensing Range 8-80 in. Narrow Sensing Beam LED Strength Indicator Short Circuit Protected Wide Temperature Range Selectable Inverted & Non- Inverted Outputs Analog Current

More information

Analog Modules AS-i, IP67, M12

Analog Modules AS-i, IP67, M12 Analog Modules, M12 2 x 2 connectors for compact housing, IP67 (Figure similar) Figure Type Inputs analog Outputs analog M12 connection Input voltage (sensor supply) Output voltage (actuator supply) (2)

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

ADDJOG User Guide 7/30/10. Overview

ADDJOG User Guide 7/30/10. Overview ADDJOG User Guide 7/30/10 Overview The ADDJOG is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The ADDJOG has 64 open collector outputs and 64 non-isolated inputs.

More information

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

RM-BC. DIN Rail Mount BCD to SSI Converter. Quality System

RM-BC. DIN Rail Mount BCD to SSI Converter. Quality System RMBC DIN Rail Mount BCD to SSI Converter Quality System Introduction This manual addendum contains information for the installation of the RMBC BCD to SSI (synchronous serial interface). The RMBC converter

More information

Instruction Manual. BMS CARD Model: DP-OPT-CARD-OP. Supplied by: - Retrofit to (or supplied with) DIGICHEM Plus + Controllers

Instruction Manual. BMS CARD Model: DP-OPT-CARD-OP. Supplied by: - Retrofit to (or supplied with) DIGICHEM Plus + Controllers Instruction Manual BMS CARD Model: DP-OPT-CARD-OP - Retrofit to (or supplied with) DIGICHEM Plus + Controllers - 4-20mA Outputs - NPN Open Collector Status Outputs for Power Failure, Flow, Alarm & Individual

More information

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date: Class: Date: MECH1500Quiz1ReviewVersion2 True/False Indicate whether the statement is true or false. 1. The number and type of I/Os cannot be changed in a fixed PLC. 2. In a PLC system, there is a physical

More information

Solid State Remote Power Controller E /627

Solid State Remote Power Controller E /627 Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves

More information

Amplifier User Manual - Ver. 1.0

Amplifier User Manual - Ver. 1.0 Bluetooth Embedded Amplifier - Ver. 1.0 www.sunhydraulics.com SARASOTA, FL USA COVENTRY, UK ERKELENZ, GERMANY MERIGNAC, FRANCE INCHEON, KOREA SHANGHAI, CHINA BANGALORE, INDIA Index 3 4 6 8 9 Product Overview

More information

LVX Control Unit. Features:

LVX Control Unit. Features: Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count

More information

Blue Point Engineering

Blue Point Engineering Blue Point Engineering SV203 Interface Overview Overview Sensors Light Sensor Motion Sensor Joystick Computer USB PORT Technical Pointing the Way to Solutions! T http://www.bpesolutions.com Animatronic

More information

Environdata FA ma Converter Guide

Environdata FA ma Converter Guide FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,

More information

Photoelectrics Retro-reflective Type PA18C.R..., DC

Photoelectrics Retro-reflective Type PA18C.R..., DC Photoelectrics Retro-reflective Type PA18C.R..., DC Miniature sensor range Range: 6.5 m (Axial), 5 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to

More information

HFX series I First generation Hall effect joysticks

HFX series I First generation Hall effect joysticks an APEM Group Company HFX series I The HFX Series I Joystick is designed for precision finger operated applications requiring proportional control and long trouble-free life. Featuring non-contacting Hall

More information

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM 100 PLUS COLLISION AVOIDANCE SYSTEM The 100 Plus collision avoidance system is intended for use with bridges and trolleys to prevent collisions or to limit the approach of adjacent bridges or trolleys.

More information

MOTION CONTROL SOLUTIONS

MOTION CONTROL SOLUTIONS CONTINENTAL HYDRAULICS MOTION CONTROL SOLUTIONS CEM Modules Software Tools Accessories MOTION CONTROL SOLUTIONS ence output v (0 ma) Reference output v (0 ma) Input 0 to /0v or to 0 ma pers 0 & 9 oltage

More information

Solid State Relays and Timers Family

Solid State Relays and Timers Family Solid State Relays and Timers Family Vehicle Control Modules Waytek Stock No. Volt Rating Amp Rating Notes Dual Input Relay Activating either Input A or Input B sets output. 75532 12 15 Dual inputs Latching

More information

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301 Instruction book IQAN-LSL Publ no HY17-8367/UK Edition 0301 Contents 1 Introduction......................................................2 2 Precautions.......................................................3

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

STAC5 Stepper Drives. A high performance, compact and cost-effective stepper drive with advanced features and control options

STAC5 Stepper Drives. A high performance, compact and cost-effective stepper drive with advanced features and control options STAC5 Stepper Drives A high performance, compact and cost-effective stepper drive with advanced features and control options Ethernet & EtherNet/IP Advanced Current Control Anti-Resonance Torque Ripple

More information

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P Type designation Ident-No. 6811073 Nominal system voltage System power supply Admissible range V+ Nominal current V+ Max. current V+ Electrical isolation Via DeviceNet 18 30VDC 430 ma 4 A The 8XSG I/O

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 12- Relay Board P/N 103190 and 103338 PAGE 1 of 13 1. REVISI LOG... 2 2. OVERVIEW... 3 2.1. PART NUMBERS... 3 2.2. MODULE

More information

TECHNICAL DATASHEET #TDAX023300

TECHNICAL DATASHEET #TDAX023300 Preliminary TECHNICAL DATASHEET #TDAX023300 2 Universal Inputs, Dual Universal Valve Controller 2 Universal Inputs 2-3A Outputs CAN (SAE J1939) Configurable with Electronic Assistant P/N: AX023300 Features

More information

HYDRAULIC DIGITAL CONTROLLER DIN Single or Dual Proportional Outputs Handheld Programmer

HYDRAULIC DIGITAL CONTROLLER DIN Single or Dual Proportional Outputs Handheld Programmer TECHNICAL DATASHEET #TD1200AX HYDRAULIC DIGITAL CONTROLLER DIN 43650 Single or Dual Proportional Outputs Handheld Programmer The digital controller supplies one or two proportional solenoid coils with

More information

PLUS+1 GUIDE Software. JS6000 PWM Service Tool User Manual

PLUS+1 GUIDE Software. JS6000 PWM Service Tool User Manual PLUS+1 GUIDE Software JS6000 PWM Service Tool TEMP 1 6 1 6 12 7 12 7 About this Manual Organization and Headings To help you quickly find information in this manual, the material is divided into sections,

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F035-20/E Proportional relief valves type AGMZO-AES two stage, without integral pressure transducer, ISO 6264 size 10, 20 and 32 1 MODEL CODE AGMZO Proportional pressure relief valve

More information

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Instruction book IQAN-LST. Publ no HY /UK Edition 0301 Instruction book IQAN-LST Publ no HY17-8364/UK Edition 0301 Contents 1 Introduction......................................................2 2 Precautions.......................................................3

More information

MODEL SIB-V245 / V453

MODEL SIB-V245 / V453 WILKERSON INSTRUMENT CO., INC INSTALLATION & OPERATION MANUAL SCADA INTERFACE BOARD MODEL SIB-V245 / V453 FOR MOTOROLA ACE3600 MIXED I/O MODULE RoHS Compliant UL/cUL Recognized Motorola is a registered

More information

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2 OPERATING PROCEDURES for the Universal Power Supply Series 2 Vanguard Instruments Co., Inc. 1520 S. Hellman Ave. Ontario, California 91761 TEL: 909-923-9390 November 2013 FAX: 909-923-9391 REV. 2 SAFETY

More information

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES 11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet

More information

In addition to fan control, many other hydraulic control applications can be accommodated with this hardware and application-specific software.

In addition to fan control, many other hydraulic control applications can be accommodated with this hardware and application-specific software. TECHNICAL DATASHEET #TDAX020300 HYDRAULIC FAN CONTROLLER with Multiple I/O 3 Temperature Sensors and 1 PWM Temperature Signal 4 Digital Input Functions and 1 Analog Override Input 1 Proportional and 1

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 18 Input module (selectable polarity) with 3 outputs (selectable polarity) with 1 analog (selectable 0-5V or 4-20mA)

More information

MS series Mid-size Hall effect joysticks

MS series Mid-size Hall effect joysticks Distinctive features and specifications Compact size 1, 2 and 3 axis configurations Sealed up to IP68 Available with USB Redundant outputs available 1 million life cycles Available with J1939 CANbus and

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION RY4 SERIES SAFETY RELAYS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.co.uk

More information

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD On-machine Compact fieldbus I/O block DeviceNet slave 125 / 250 / 500 kbps Two 5-pole M12 connectors for fieldbus connection 2 rotary switches for node address IP67, IP69K M12 I/O connectors LEDs indicating

More information

Diagnostics (Logical) Diagnostics (Physical)

Diagnostics (Logical) Diagnostics (Physical) Enclosure Mounted Input/Output Stations In-Cabinet I/O IP 20 Protection Ideal for Retrofits Automatic Baud Rate Sensing FDN20-4S-4XSG FDN20-4S-4XSG-E* FDN20-4S-4XSG-DIN* * Not UL Electrical Operating Current:

More information

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD On-machine Compact fieldbus I/O block DeviceNet slave 125 / 250 / 500 kbps Two 5-pole M12 connectors for fieldbus connection 2 rotary switches for node address IP67, IP69K M12 I/O connectors LEDs indicating

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending) Hypot III DIELECTRIC WITHSTAND TESTERS For Production Line Safety Agency Compliance Testing Graphic Liquid Crystal Display 10 Memories with 3 Steps per Memory Low Limit Detection System 3605 AC Hipot SmartGFI

More information

Multi-axis controller V 8 / VV 8

Multi-axis controller V 8 / VV 8 Multi-axis controller V 8 / VV 8 /30 03 The multi-axis controller V 8 is a rugged switching device according IEC/EN 947-5- for electro-hydraulic applications.the modular design enables the switching device

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

Data Sheet for Joysticks

Data Sheet for Joysticks Up to two pushbuttons in handle Protection Grade up to IP68 Optionally available with USB and CAN (J99) The TRY50 series covers the transition from finger- to handsize joysticks. This has been realized

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1 TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and

More information

Premium Welding Intelligence solutions for any brand of welding power source, designed to integrate with Insight Centerpoint.

Premium Welding Intelligence solutions for any brand of welding power source, designed to integrate with Insight Centerpoint. Insight ArcAgent Issued Sept. 2016 Index No. WI/1.0 Welding Intelligence Premium Welding Intelligence solutions for any brand of welding power source, designed to integrate with Insight Centerpoint. ArcAgent

More information

Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 4401 size 06

Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 4401 size 06 www.atos.com Table F007-20/E Proportional relief valves type RZMO-A* direct operated, without integral pressure transducer, ISO 440 size 06 Valve body Proportional solenoid Spring Poppet Integral electronics

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

The TCMS Solution ionia Train control by duagon

The TCMS Solution ionia Train control by duagon ionia Train control by duagon The small, space-saving and innovative one-for-all solution with the complete duagon train communication and control expertise. The TCMS Solution Space-saving and powerful

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION SL4 (014) SERIES SAFETY LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.co.uk,

More information

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik PT2060/ System Interface Module ProvibTech s PT2060/ module is a communication and system interface module. This module is used to: module. The two phase reference channels can be used to provide phase

More information

Premium Welding Intelligence solutions for any brand of welding power source, designed to integrate with Insight Centerpoint.

Premium Welding Intelligence solutions for any brand of welding power source, designed to integrate with Insight Centerpoint. Insight ArcAgent Issued June 2017 Index No. WI/1.0 Welding Intelligence Premium Welding Intelligence solutions for any brand of welding power source, designed to integrate with Insight Centerpoint. ArcAgent

More information

VersaMax Micro and Nano Technical Product Presentation

VersaMax Micro and Nano Technical Product Presentation VersaMax Nano VersaMax Micro VersaMax Micro and Nano Technical Product Presentation Outline Introduction VersaMax Micro and Nano Product Strategy Future Products Product Description VersaMax Nano VersaMax

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Digital Proportional Power Plug

Digital Proportional Power Plug Digital Proportional Power Plug GB Installation and startup guideline for Digital Power Plug for proportional valves EHH-AMP-702-D/C/K-R-P-1-30 EHH-AMP-712-D/G-R-P-1-30 EHH-AMP-702/712-N-C-N-3-30 EHH-AMP-702-D-R-P-2-30

More information

Advanced Features. High Performance Stepper Drive Description. Self Test and Auto Setup

Advanced Features. High Performance Stepper Drive Description. Self Test and Auto Setup www.applied-motion.com STAC6 High Performance Stepper Drive Description The STAC6 represents the latest developments in stepper drive technology, incorporating features that will derive the highest performance

More information

Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20

Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20 www.atos.com Table F050-8/E Proportional reducing valves type AGRCZO-AES two stages, normally closed, without integral pressure transducer, ISO 5781 size 10 and 20 Main poppet Pilot relief valve type RZMO

More information

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0 monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts

More information

Transducers for Pt-100/1000, Resistors

Transducers for Pt-100/1000, Resistors Transducers for Pt-100/1000, Resistors Microprocessor-based technology General Description Isolating transducers with digital programming of ranges, for DIN-rails or for printed circuit boards. Modules

More information

User s Manual Hub444. Motion Control Network Hub

User s Manual Hub444. Motion Control Network Hub 8/23/02 JK User s Manual Motion Control Network Hub Applied Motion Products, Inc. 404 Westridge Drive Watsonville, CA 95076 Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544 motors drives controls -2-

More information

UNIVERSAL CURRENT CONVERTER

UNIVERSAL CURRENT CONVERTER UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.

More information

Photoelectrics Diffuse-reflective Type PA18C.D..., DC

Photoelectrics Diffuse-reflective Type PA18C.D..., DC Photoelectrics Diffuse-reflective Type PA18C.D..., DC Miniature sensor range Range: 1 m (Axial), 0.8 m (Radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage: to 30

More information

SYSMAC Remote Transistor Module

SYSMAC Remote Transistor Module 9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models

More information

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and

More information

Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC

Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC Miniature sensor range Range: 5 m (axial), 4 m (radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage:

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

EM-F-7G Safety Extension Module

EM-F-7G Safety Extension Module EM-F-7G Safety Extension Module One-channel control with four safety output channels Features Safety Extension Module provides additional safety outputs for a Primary Safety Device (for example, an E-stop

More information

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual 5304 Analog Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

NO - NPN PSC10-30GI70-E PSC10-30GI70-E-V1 NO - PNP PSC10-30GI70-E2 PSC10-30GI70-E2-V1

NO - NPN PSC10-30GI70-E PSC10-30GI70-E-V1 NO - PNP PSC10-30GI70-E2 PSC10-30GI70-E2-V1 CONSTANT DISTANCE INDUCTIVE SENSOR M0 wire Cable or Connector NPN PSC00GI70E PSC00GI70EV PNP PSC00GI70E PSC00GI70EV Drawing Sensing distance Sn 0 mm 0 mm Operational sensing distance 8. mm 8. mm Detectable

More information

TECHNICAL DATASHEET #TDAX023240

TECHNICAL DATASHEET #TDAX023240 Preliminary TECHNICAL DATASHEET #TDAX023240 2 Quadrature Decoder Inputs, Dual Valve Controller 2 Quadrature Decoder Inputs 2-3A Outputs CAN (SAE J1939) Configurable with Electronic Assistant P/N: AX023240

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 16 Output module (selectable polarity) P/N 610-00031 PAGE 1 of 10 1. REVISION LOG... 1 2. MODULE OVERVIEW... 2 2.1. SCOPE...

More information

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER ZENSOL AUTOMATION INC. COMPUTERIZED TEST EQUIPMENT ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER CBA-32P Micro CBA MANUAL 1W E OPERATOR S GUIDE Version 1.70 January 2001 www.zensol.com Man-1we.doc Rév 5

More information

CJ series Ergonomic multifunction joysticks

CJ series Ergonomic multifunction joysticks an APEM Group Company CJ series The CJ Series joystick features an ergonomic multifunction handle purposely designed for safety critical hand-operated applications. Available as a one or two axes joystick,

More information

Electronic Control Unit RC

Electronic Control Unit RC Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Electronic Control Unit RC RE 900/.0 /6 Replaces: 09.0 Series

More information

COMPACT CATALOGUE DPC130 REMOTE CONTROL

COMPACT CATALOGUE DPC130 REMOTE CONTROL COMPACT CATALOGUE DPC130 REMOTE CONTROL Features H Direct interface to DPC130 equipped with 8EZR. H Mini series joystick for finger tip operations. H Maxi series joystick ready for all Walvoil handles.

More information

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

Typical Input current at  1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A SmartPower TM The Autotech SmartPower is a DC switching power supply with 24V output Voltage. This user friendly power supply has two 7-segment LED displays for voltage and current monitoring. This DC

More information

Programmable Meter for Analog Sensors/Transducers

Programmable Meter for Analog Sensors/Transducers Programmable Meter for Analog Sensors/Transducers Supply Voltage: 11-28 VDC (nominal 24 VDC) * If using a TDRO10A2 in current analog output mode 11.5-28 VDC Temperature Range: 0 to 70 C Interface: 0 to

More information

Proportional relief valves type RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06

Proportional relief valves type RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06 able TF035-1/E Proportional relief valves tpe 110106 RZMO-A* with Pmax 500 bar direct operated, without integral pressure transducer, ISO 4401 size 06 9 10 Valve bod Proportional solenoid Spring Poppet

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

PC2004 PRESSURE CONTROLLER

PC2004 PRESSURE CONTROLLER PC CTROLLER FRT PANEL Digital Display & Display Selector Switch The Display Selector Switch has five positions: PRESS Displays the pressure sensed at the transducer. INT SP Displays the INTERNAL SETPOINT

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

EEET 2204 Industrial Automation

EEET 2204 Industrial Automation EEET 224 Industrial Automation EEET 224 Industrial Automation by Dr Peter Graszkiewicz. Discrete-State Control.. Basic Input and Output Devices 3-phase power supply N/C N/O contactor terminals fuses contactor

More information

HI-POT TESTER. User s Manual

HI-POT TESTER. User s Manual HI-POT TESTER 7620 User s Manual Contents 1. Before Use... 1.1Electric Shock Avoidance... 4 1.2 Grounding... 4 1.3 AC Power Supply... 4 1.4 Connecting Test Leads... 4 1.5 Warm Up... 4 1.6 External Control...

More information

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings for Display of High-speed Addition and Subtraction Maximum operating speed 2kHz Used in industrial machinery, end-measuring devices, and the like, this electronic counter is exclusively for display. It

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

OMNITERM LPI & LPD Loop Powered Isolators DATASHEET. Model C2063B LPI (single) & C2462A LPD (dual) 4-20mA Loop Powered Isolators.

OMNITERM LPI & LPD Loop Powered Isolators DATASHEET. Model C2063B LPI (single) & C2462A LPD (dual) 4-20mA Loop Powered Isolators. Model C0B (single) & CA LPD (dual) 0mA Loop Powered Isolators Features Isolate any instrument current loop to 0ac Powered by the current loop no power supply required Lowest volt drop < Volts at 0 ma (,V

More information

Installation & Operation and Maintenance

Installation & Operation and Maintenance Gas Safety Products Dual Current Monitor Installation & Operation and Maintenance Read these instructions carefully before operating or servicing Rev: 01 Date: 12-02-18 1 CONTENTS Chapter Content Page

More information