4 DTY-EPU Thank you very much for purchasing the EP Monitor DTY-EPU. Please read this Owner s Manual carefully and thoroughly for the correct and optimum use of the EP Monitor. Kindly keep this manual in a convenient place for quick reference. Specifications EP Monitor Model Item Voltage Current Number of inputs Sensor input Voltage range Maximum applied Number of outputs Method Switch output Applied Current Voltage drop Electric potential Switch output check Input channel check key switch Communication I/F Operating temperature range Operating humidity range Storage temperature range Case material Outer dimensions Mass Accessories Notes:. At EP Sensor in unconnected state. When in the ion balance monitor mode, the unit is V (no decimal point). General Precautions Wiring. When using a switching regulator obtained on the market for the power supply, always ground the frame ground (F.G.) terminal.. When using equipment (switching regulator, inverter motor, etc.) that can become a source of noise around the EP Sensor mounting area, always ground the equipment frame ground (F.G.) terminal.. When wiring is completed, check that there is no error in the wiring connections.. Although this monitor can monitor the conditions of up to EP Sensors at the same time, the EP Sensor settings are performed unit at a time. This is performed by connecting the communication cable for each EP Sensor to be set. Others. Check power supply fluctuations to ensure that power input does not exceed the rated value.. Avoid use during the transient period (0.s) when the power is switched on.. Do not use needle tips or other sharp points to perform key. Mounting Sensor and connector connection procedure Connect the EP Sensor DTY-EPS and the mini clamp connector. Follow the procedure below to perform the connections.. Check that the connector cover (the part where lead wires are to be inserted) is protruding from the connector body. It cannot be used if it s flat and placed at the same level against the body. u EP Monitor (Dedicated for EP Sensor) Owner s Manual Ver..0 This product is intended for detection of targeted objects, and does not have control functions for the purposes of accident prevention or other safety measures. DTY-EPU VDC0% 00mA MAX Note channels VDC.V NPN open collector DC MAX 0mA MAX 0.V MAX/At ma -segment LED digits, Unit: kv (with decimal point) Note Red LED pcs. Green LED pcs. Pushbutton type, keys (UP, DOWN, MODE) Conformity with RSC 00 C [ F] 0%RH 00 C [ F] PBT 0(W)mm0(H)mm(D)mm Approximately g [.oz.] Mini clamp wire mount plug pcs.. Arrange the EP Sensor cable into the required form. Since the insulation on the tips of the lead wires have been peeled off and soldered, cut the wires at about 0mm [0.in.] from the tips so that they do not protrude from the insulation. Cut Caution Ground terminal Caution: Handle any unused lead wires so that they will not short circuit.. Follow the instructions in the table to insert the lead wires into the hole in the connector cover. Look through the top of the semi-transparent cover to check that the lead wires have been firmly inserted all the way to the back. (Insertion is about mm [0.in.].) Use caution in making the connections, since switching on the power with mistakes in the connections will damage the EP Sensor and EP Monitor. No. on the connector EP Sensor Signal name EP Sensor power supply () EP Sensor analog output EP Sensor power supply () EP Sensor abnormality Yellow/black wire Gray/red wire Color of lead wire EP Sensor yellow/red wire EP Sensor white/red wire EP Sensor yellow/black wire EP Sensor gray/red wire Yellow/red wire White/red wire EP Sensor. Taking care to avoid letting the lead wires slip out from the connector, use pliers or some other hand tool to crimp the cover and connector body, and push the cover into the connector body. Limit the crimping force to 0.N [0lbf.]. When the cover is flat and placed at the same level against the connector body, the connection is complete.. Check one more time that the wiring is correct. Attaching and removing of the EP Sensor, and the power supply, switch, and communication cable Lock lever Lock lever EP Sensor DTY-EPS Power supply, switch, and communication cable DTY-EPP-- Connector for EP Sensors Connector for power supply, switch, and communication cable To mount the EP Sensor and the power supply, switch, and communication cable, align the lock lever position as shown in the figure, and push until the lock hooks on the controllerside connector. To remove, push down hard on the lock lever, take the connector and pull it out. At this time, be careful to avoid applying unnecessary force on the lead wires. Attaching the panel mounting parts and protective front cover Mounting body Protective front cover (sold separately) ) ) ) Groove on panel mounting body Attaching the mounting bracket EP Sensorch EP Sensorch EP Sensorch EP Sensorch Connect to each EP sensor, and set -M.0. Depth [0.in.] (Mounting thread) Hex socket head screw (Provided with mounting bracket) (Yellow/red)V (Yellow/black) (Yellow/red)V (Yellow/black) (Yellow/red)V (Yellow/black) (Yellow/red)V (Yellow/black) Mounting bracket PSU-BR Panel plate Mounting holder ) EP Monitor ) Insert the mounting body from the front of the panel hole. ) Insert the sensor controller from the back of the mounting body. ) From the back of the position in ), place the mounting holder on the mounting body groove, and insert it. ) Set the separately sold protective front cover in place. For removal, follow the above procedure in reverse, using a screwdriver or other tool to remove the mounting holder. EP Monitor Internal circuit Use the hex socket head screws (M.0., length mm [0.in.]) to mount the mounting bracket into the mounting holes on the back of the sensor controller. The tightening torque should be 0.Nm [.inlbf]. Internal Circuit and Wiring Specifications (External Connection Example) Power supply and switch output cable Color of lead wire (Red)V Load (White) SW 0mA MAX Load (Green) SW 0mA MAX Load (Yellow) SW 0mA MAX Load (Brown) SW 0mA MAX (Black) Communication Note cable External connection example VDC 0% Note: Power supply, switch, and communication cable DTY-EPP-CC-L is available. Note: When the cable is extended, be aware that will drop due to resistance in the cable. Key to codes D: Reverse current protection diode for power supply ZDZD: Zener diode for surge absorption TrTr: NPN output transistor Major Parts and Functions q r w e t y Figure Name q LED (red) Displays the detected electric potential value, setting contents, and error content w Switch output indicator (red) Lights up when switch output is ON e Autoscan indicator (green) Channel ing current electric potential lights up r UP key ( ) Used when adjusting setting value upward t DOWN key ( ) Used when adjusting setting value downward y Mode key ( ) Used for all types of settings Judgment Output Voltage : MAX (Threshold) : MIN (Threshold) ON Judgment output OFF High value, low value (threshold MAX, MIN) Electric Potential Display Electric potential mode Figure Switching on the power supply (VDC ) automatically provides electric potential mode. Electric potential unit for ion balance monitor mode: V, for other modes: kv. When the kv is used, it becomes a decimal point. The electric potential of the selected channel is indicated in the LED. (The selected channel s A.S.OUT LED (green) lights up. See Figure.) The SW.OUT LED (red) lights up when the switch output is turned ON. Pressing the key or key changes the selected channel. When in auto switch, pressing the,, or key returns the to the electric potential at fixed channel. If appears, it means that the selected channel s EP Sensor was not connected or has a wire break. In the case of a wire break, shut off the power and replace the EP Sensor. EP Monitor s Caution. Since miswiring in the EP Sensor, or in the power supply, switch, and communication cable, can damage both the EP Monitor and EP Sensor, always check the wiring before switching on the power.. The setting conditions are written to EEPROM and saved. Be aware that EEPROM has a finite lifetime, with a write guarantee times up to 00,000 times. preparation Connect the connector to the EP Sensor cable. Connect the EP Sensor ( to units), and the power supply, switch, and communication cable to the EP Monitor. EP Monitor setting procedure of EP Sensor positioning distance Perform settings for the EP Sensors used in each channel. Judgment output setting Set the high and low values for each channel. Detection Complete the settings and start detection. i
5 s High value settings EP Sensor s EP Monitor method EP Monitor setting items (SET) Measurement distance -seg item Ib mm < mode> 0mm 0mm 0mm 0mm 0mm kV.00kV IB monitor mode EP Sensor distance to 0mm EP Sensor distance to 0mm EP Sensor distance to 0mm EP Sensor distance to 0mm EP Sensor distance to 0mm When in IB monitor mode 0mm High value kV0.00kV 0mm kV.00kV 0mm Low value kV0.00kV 0.00kV0.00kV kV.00kV 0.00kV0.00kV.00kV.00kV 0.00kV0.00kV 0.00kV0.00kV 0mm 0mm When in IB monitor mode 0mm 0mm 0mm 0mm 0mm EP Monitor zero adjustment (SET) item CH CH CH CH EP Monitor method EP Monitor settings Automatic channel setting o -seg [Display channel setting] AS-: ch to AS-: ch to AS-: ch to ESC: Return Measurement distance range settings -seg [Measurement distance settings] Ib: mode 0: 0mm range EP Sensor to 0mm 0: 0mm range EP Sensor to 0mm 0: 0mm range EP Sensor to 0mm 0: 0mm range EP Sensor to 0mm 0: 0mm range EP Sensor to 0mm ESC: Return SEt, SEt Press or for AutoScan CH, CH, CH, CH, Auto Press or for AutoScan Press or for AutoScan Press or for AutoScan Press or for AutoScan Press or for ch. AS-, AS-, AS- Electric potential is switched automatically. Channel switching is performed automatically. Press or for channel Press or for distance Displayed for sec. Perform settings to match the EP Sensor positioning distance (between an object targeted for measurement and EP Sensor) and EP Sensor distance setting. After sec. -seg SEt, SEt CH, CH, CH, CH, Auto Ib, 0, 0, 0, 0, 0 Threshold value (MAX) set when using the EP Monitor switch output (judgment output). 0mm 0mm 0mm 0mm 0mm Press or for channel Press or for setting item Press or for CPH Press or for Displayed for sec kV 0.00kV.00kV 0.00kV 0.00kV Low value settings 0mm 0mm 0mm 0mm 0mm Zero adjustment After sec. -seg 00.00kV 0.00kV.00kV 0.00kV 0.00kV Press or for setting mode Press or for setting mode Press or for channel Displayed for sec. SEt, SEt CH, CH, CH, CH, Auto 00.00kV 0.00kV.00kV 0.00kV 0.00kV Threshold value (MIN) set when using the EP Monitor switch output (judgment output). -seg Press or for channel Press or for setting item Press or for CPL Press or for CPL Press or for After sec. Displayed for sec. SEt, SEt CH, CH, CH, CH, Auto 00.00kV 0.00kV.00kV 0.00kV 0.00kV Adjustment when the is not 0.00 when there is 0 volt input to the EP Sensor. After sec. After sec. -seg SEt, SEt, SEt SEt, SEt, SEt SEt, SEt, SEt ref, ref, ref, ref, ESC This is a setting method when using the EP Monitor to set the EP Sensor. If using support software for setting from a personal computer, see the EP Sensor Owner s Manual. CAUTION The EP Sensor setting is performed for the EP Sensor that is connected to the communication cable. If setting multiple EP Sensors, the cable will have to be unplugged and reconnected to connect each time. preparation Connect the connector provided to the EP Sensor cable. Connect the EP Sensor ( to units), and the power supply, switch, and communication cable to the EP Monitor. Connect the communication cable plug to the jack for the EP Sensor being set. If performing settings for multiple EP Sensors, unplug and reconnect each time when a setting is performed. The power can be left on while the plug is unplugged and reconnected. EP Sensor setting procedure the EP Sensor conditions Set the values for the measurement distance, high value setting, low value setting, output, mode, and data output cycle. Sending the EP Sensor setting value Send the values set for the measurement distance, high value setting, low value setting, output, mode, and data output cycle. EP Sensor adjustment In the EP Sensor electric potential input state, perform zero calibration for the EP Sensor. EP Monitor adjustment With the EP Sensor at, perform the EP Monitor adjustment. Display Completes the settings, and starts electric potential. s EP Sensor setting items (SET) item High value Low value Voltage output enabled/disabled Operation mode Data output cycle Judgment output reset Zero calibration value sending -seg When EP Sensor comparative judgment output is ON Send the values set for the measurement distance, high value setting, low value setting, output, mode, and data output cycle. Judgment output release Perform alarm reset for the EP Sensor. Ib, mm, mm0mm 0000 At mm setting, is Ib When in mode kv.00kv 0mm kV0.00kV 0mm kV.00kV 0mm kV0.00kV 0mm kV0.00kV 0mm When in IB monitor mode kv.00kv 0mm kV0.00kV 0mm kV.00kV 0mm kV0.00kV 0mm kV0.00kV 0mm CPE0 CPE A0 A Voltage output disabled Voltage output enabled Averaged data output mode Actual measured data output mode Automatically sets to A IB monitor mode distance = mm, and cycle = 0. sec. t.0 t0. t0. t0. sec. 0. sec. 0. sec. 0. sec. Sensor alarm reset executed Sensor CAL executed Sending sensor setting value executed Disabled in IB monitor mode Only changing the value is not enough to set this item. The change becomes valid when SEnd is executed. EP Sensor settings Measurement distance settings Perform settings to match the EP Sensor positioning distance (between object targeted for measurement and EP Sensor). -seg Press or for setting mode SEt, SEt Press or for setting mode SEt, SEt Press or for distance Ib, -0 After sec. Displayed for sec. [Measurement distance settings] Ib: IB monitor mode 0: 0mm High value settings Threshold value (MAX) set when using the EP Sensor judgment output -seg Press or for setting mode SEt, SEt Press or for setting mode SEt, SEt Displayed for sec. Press or for After sec. 0mm 0mm 0mm 0mm 0mm 00.00kV 0.00kV.00kV 0.00kV 0.00kV Voltage setting range 00.00kV 0.00kV.00kV 0.00kV 0.00kV Low value settings Threshold value (MIN) set when using the EP Sensor judgment output. -seg Press or for setting mode Press or for setting mode Displayed for sec. Press or for After sec. 0mm 0mm 0mm 0mm 0mm 00.00kV 0.00kV.00kV 0.00kV 0.00kV Voltage setting range 00.00kV 0.00kV.00kV 0.00kV 0.00kV!0
6 Comparative output enabled settings Sets whether to use or not use the EP Sensor judgment output. -seg Press or for setting mode SEt, SEt Press or for setting mode SEt, SEt Press or for comparative output enabled/disabled setting Displayed for sec. CPE0, CPE After sec. [Enabled/disabled settings] CPE0: Invalid CPE: Valid Operation mode settings There are modes, averaged data output, actual measurement data output, and ion balance monitor mode. -seg Press or for setting mode SEt, SEt Press or for setting mode SEt, SEt Displayed for sec. Press or for mode A0, A, A 0 After sec. [Mode settings] A0: Averaged data output mode A: Actual measurement data output mode A: IB monitor mode Judgment output clear execution Sets judgment output to OFF. -seg Press or for setting mode SEt, SEt Press or for setting mode SEt, SEt 0 After sec. Displayed for sec. Execution result Executes the Judgment output clear in sensor setting. Execution result Executes the Zero calibration in sensor setting. Communication output data rcr Zero calibration execution Performs zero adjustment for the EP Sensor. -seg Press or for setting mode SEt, SEt Press or for setting mode SEt, SEt 0 After sec. Displayed for sec. Communication output data zcr Data output cycle settings Sets the data output refresh cycle. -seg Press or for setting mode Press or for setting mode 0 After sec. Press or for output refresh cycle Displayed for sec. [Cycle settings] t.0: sec. t0.: 0. sec. t0.: 0. sec. t0.: 0. sec. SEt, SEt SEt, SEt, CPE, A, Int, CPr, CAL, CPE, A, Int, CPr, CAL, CPE, A, Int, CPr, CAL, CPE, A, Int, CPr, CAL, CPE, A, Int, CPr, CAL, CPE, A, Int, CPr, CAL t.0, t0., t0., t0. value sending execution Sends content of each EP Sensor settings to the EP Sensor, and registers the setting. -seg Press or for setting mode SEt, SEt Press or for setting mode SEt, SEt 0 After sec. Displayed for sec. Execution result Executes the Sending set value in sensor setting. Communication output data X, XX, and XXX represent numeric data. The actual ed numbers are determined by the setting contents. Error Display! Display Error description Sensor on selected channel either not connected or has a wire break. Sensor input value falls short of the measurement range. Sensor input value exceeds the measurement range. Abnormal sensor input (P-IN) is ON. Switch output is an overcurrent. Error cancel Perform correct sensor connection. Eliminate the cause of the error occurrence. OVERSEAS DEPARTMENT --, Midori-cho, Koganei City, Tokyo -, Japan Tel: 0-- Fax: 0-- URL
EP Sensor. Environmentally friendly RoHS Compliant Product. Optimum sensor for electrostatic monitoring of automated lines arrives!
Catalog No.BK-R0002 ISO 9001 / ISO 14001 Environmentally friendly RoHS Compliant Product Optimum sensor for electrostatic monitoring of automated lines arrives! Environmentally friendly RoHS compliant
More informationElectrostatic Potential Sensor
Catalog No. BK-P044 Electrostatic Potential Sensor RoHS compliant product Introducing small sensors perfect for monitoring static electricity in-line! These sensors can constantly monitor and measure the
More informationCan eliminate static charge over an extensive range
No.BK-P3 Static Electricity Removing Unit Ionizer Wide Area Fan Type Overhead Fan Type Can eliminate static charge over an extensive range Wide area fan type RoHS compliant product Overhead fan type Static
More informationPlug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs
1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector
More informationSuitable for detecting transparent films or transparent bottles
Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16
More informationPM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection. Hardly affected by background
PHOTO PHOTO USE MEASUREMENT STATIC CONTROL Micro Photoelectric SERIES Related Information General terms and conditions... F- Glossary of terms... P.39~ selection guide... P.~ General precautions... P.0
More informationPM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection
3 Micro Photoelectric PM SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.~ Amplifier Built-in selection guide... P.7~ General precautions... P.8~ PHOTO PHOTO Conforming
More informationGL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.
811 Compact & ow Price Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.176~ guide... P.781~ General precautions... P.179~ PHOTO PHOTO MEASURE
More informationPM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection
PHOTO PHOTO Micro Photoelectric PM SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.9~ Amplifier Built-in guide... P.393~ General precautions... P.~ Certified MEASURE
More informationConvergent Reflective Micro Photoelectric Sensor
EQ- VF NX PM MS-AJ RT- PX- CY PHOTOELECTRIC SENSORS Mounting Stand Amplifier Built-in SERIES Convergent Reflective Micro Photoelectric Stable detection by convergent reflective mode Stable detection characteristics
More informationPM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection
3 Micro Photoelectric PM SERIES Related Information General terms and conditions...p. Glossary of terms...p.983~ selection guide...p.~ / P.9~ General precautions...p.98~ Amplifier Built-in PHOTO PHOTO
More informationEF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!
1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible
More informationOptimum sensing capability for LCD manufacturing
SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection
More informationEven a specular background does not affect the sensing performance if the sensor is located 30mm away from it (when directly opposite).
SERIES Convergent Reflective Micro Photoelectric Convergent Reflection Sensing Ensures Stable Detection Marked Conforming to EMC Directive Stable Detection by Convergent Reflective Mode Stable detection
More informationConnector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable
44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in
More informationDC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range
INDUCTIVE SERIES DC 3-wire Cylindrical Inductive Proximity Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance and environmental resistance at low price GA-/GH GX GX-U/FU
More informationLCD Readout Digital Pressure Switch
LCD Readout Digital Pressure Switch Series 3 (For )/ 3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display Can be integrated with a vacuum unit, Series ZX Built-in
More information1-channel Flow Rate Sensor Controllers
-channel Flow Rate Sensor Controllers FSU Series Switch output indicator Note Note: The indicator color is red only. UP key FSU-S -digit LED display The display color can be changed to green or red. Error
More informationDC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range
INDUCTIVE SERIES DC 3-wire Cylindrical Inductive Proximity Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance and environmental resistance at low price G-8/8U GA-/GH GX GX-U/FU
More informationE2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1
Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the
More informationHigh Accuracy Eddy Current Type Displacement Sensor. Linearity 0.5 % F.S.
MEASUREMENT SENSORS SERIES High Accuracy Eddy Current Type Displacement Sensor GP-X LD LA LA-300 HL-T1 LM10 LH-0 HL-C1 Accurate measurement of minute displacements Minute displacement of metallic objects
More informationSERIES Amplifier Built-in Miniature-size Photoelectric Sensor
PHOTOEECTRIC SENSORS SERIES Amplifier Built-in Miniature-size Photoelectric EQ- Amplifier Built-in Micro-size Type RX -4 EQ- Marked Conforming to EMC Directive (Excluding -DS/DM) RX-S Remarkable Sensing
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More information4.1 Parts and Components... IV Assembly Tips... IV Assembly Precautions... IV Required Tools, Equipment and Materials..
IV PERSONALITY MODULE ASSEMBLY 4.1 Parts and Components............ IV-1 4.2 Assembly Tips............... IV-1 4.3 Assembly Precautions............ IV-1 4.4 Required Tools, Equipment and Materials.. IV-1
More informationNo. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global
Ultra-minute Photoelectric Sensor EX-Z SERIES Conforming to EMC Directive No. 1 The World s in Compactness * Among photoelectric sensors with built-in amplifier, as of June 215 (survey by our company)
More informationNEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.
NEW product No, NPPDF 6-01E Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure
More informationUSER S MANUAL High-Speed High-Accuracy Eddy Current Digital Displacement Sensor. GP-X Series
USER S MANUAL High-Speed High-Accuracy Eddy Current Digital Displacement Sensor GP-X Series ME-GPX(04) No.0031-80V Thank you for purchasing Panasonic Industrial Devices SUNX's GP-X series High-Speed High-Accuracy
More informationU-shaped Type/Convergent Reflective Type. onlinecomponents.com
PHOTOELECTRIC SENSOR SERIES U-shaped Type/Convergent Reflective Type SS-A SU-7/SH VF NX MS-AJ RT- PX- EX CY Amplifier-separated Type Multi-voltage Type Amplifier Built-in Type Mounting Stand Stable Detection
More informationpanasonic.net/id/pidsx/global
73 PHOTO PHOTO Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions... P.1566 MEASURE Simple &
More informationV E1B Snap-in I/O Module
V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital
More informationS-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter
S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter
More informationGX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available
8 Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.86~ selection guide... P.757~ General precautions... P.05 PHOTO PHOTO Conforming
More informationOperation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit
Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536
More informationCONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...
Thank you for your purchase of this product. Before operating the product, please read this instruction manual carefully to ensure proper use of the product. Please store this instruction manual in a safe
More informationMini Photoelectric Sensor
Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible
More informationGP-X SERIES Conforming to EMC Directive
High Speed High Accuracy Eddy Current Type Digital Displacement Sensor GP-X SERIES Conforming to EMC Directive 25!s &.2%F.S. High-speed sampling and high resolution. The new choice for even more variegated
More informationProduct Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series
PRODUCT NEWS Product Discontinuation Notices July 4, 2011 Presence Detection Sensors No. 2011195E Discontinuation Notice of Safety Laser Scanner Product Discontinuation Safety laser scanner Accessories
More informationNEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.
NEW product No, NPPDF 6-01E-3 Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure
More informationCommunications & Networking
8-Point Source Input & 8-Point Transistor Sink Output odule () Key features include: Communicate with network 8-point source input and 8-point sink output module Removable terminal blocks Use as remote
More informationDIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E
INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for
More informationAutoranging True RMS Multimeter User Manual
Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.
More information3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.
2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can
More informationThe World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company)
Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES Conforming to EMC Directive Recognition No. 1 The World s in Compactness * Among photoelectric sensors with built-in amplifier, as of June
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationHead-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure
689 PHOTO PHOTO Dual Display Digital Pressure Sensor DPC-L100 SERIES SERIES General terms and conditions... F-17 Sensor selection guide... P.661~ Related Information Glossary of terms... P.1373~ General
More informationSECTION 10 Analog Input/Output Option Board
SECTION 10 Input/Output Option Board This section describes how to use Input/Output Option Board. 10-1 General Specifications.......................................... 506 10-2 Part Names...................................................
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing
More informationV E2B Snap-in I/O Module
V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital
More informationTOUCH SCREEN CONTROLLER for Air Conditioning Control System
INSTALLATION MANUAL TOUCH SCREEN CONTROLLER for Air Conditioning Control System Model: BMS-TP064ACE BMS-TP064PWE BMS-TP52ACE BMS-TP52PWE Thank you very much for purchasing the TOSHIBA Touch Screen Controller.
More informationUltra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in
1 Ultra-small Micro Photoelectric PM- SERIES Related Information General terms and conditions... F-17 Glossary of terms / General precautions... P.19~ / P.10 Amplifier Built-in selection guide... P.1~
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationSiO Controller. SiO Controller. SiO-C Ver onwards SiO2/SiO2PNP Ver onwards SiO3 Ver onwards INSTRUCTION MANUAL. Version 3.
SiO Controller SiO-C Ver. 2.00 onwards SiO2/SiO2PNP Ver. 1.00 onwards SiO3 Ver. 1.00 onwards INSTRUCTION MANUAL Version 3.2 WARRANTY RANGE Warranty Period 1 year period after date of purchase 1. This product
More informationDC 2-wire Cylindrical Inductive Proximity Sensor
SERIES DC -wire Cylindrical Inductive Proximity -wire type available Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance & ease of use G-8/8U GA-/GH GX GX-N G-8H/8H G-N Robust
More informationKCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings
for Display of High-speed Addition and Subtraction Maximum operating speed 2kHz Used in industrial machinery, end-measuring devices, and the like, this electronic counter is exclusively for display. It
More informationCylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global
8 PHOTO PHOTO MEASURE Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F- Glossary of terms... P.576~ panasonic.net/id/pidsx/global guide... P.78~ General
More informationBGS (at min. setting) BGS (at max. setting)
Compact Photoelectric Sensor with Built-in Amplifier EZ-LS CSM_EZ-LS_DS_E_7_ Distance-settable Sensor Unaffected by Workpiece Color and Background Distance-settable triangulation model unaffected by color.
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82175 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationCompact Inductive Proximity Sensor
SERIES Compact Inductive Proximity Sensor Amplifier Built-in High functionality together with robust housing and flexible cable Miniature is an amplifier built-in inductive proximity sensor having a diameter
More informationWeb Site: Forums: forums.parallax.com Sales: Technical:
Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267
More informationMulti Channel Pressure Sensor Controller Operation Manual PSE200 Series
Multi Channel Pressure Sensor Controller Operation Manual PSE200 Series URL http:// www.smcworld.com Thank you for purchasing the SMC PSE200 Series Multi channel Pressure Sensor Controller. Please read
More informationNA1-5. Ultra-slim Body 25mm Beam Pitch Area Sensor. Even a Slim Hand Is Detected by the 25mm Pitch Beam Curtain AREA SENSORS.
Ultra-slim Body 2mm Pitch Area Sensor mm Thick: /2 of Conventional Model It fits into a small space, without obstructing normal operation. Clearly Visible Job Indicator Both the emitter and the receiver
More informationMPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options
Features MPS- Green Display MPS-VN-PC ure Sensors Features ure Ranges: Vacuum ure 0 to -0 inhg Positive ure 0 to 5 PSI Sensor : NPN or PNP Open Collector Transistor, 0VDC, 5mA Optional Analog, to 0mA Optional
More informationVibraLINK switchable junction boxes Installation and operating guide VLL series
VibraLINK switchable junction boxes Installation and operating guide VLL series Caution: This guide should be read carefully before installation Wilcoxon Sensing Technologies 8435 Progress Drive, Frederick,
More informationpanasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.
1123 PHOTO PHOTO PARTICUR Type Edge Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.1593~ guide... P.1021~ General precautions... P.1595 Conforming to FDA regulations
More informationOperation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit
Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications
More informationE4PA. Ultrasonic Displacement Sensor. Ordering Information
Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors
More informationOne step ahead in performance and mounting ease
95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~
More informationSwitching Power Supply
Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input
More informationNPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.
Built-in Amplifier Photoelectric Sensor E3V3 Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance. A series of models with an M8 metal junction connector
More informationBreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide
This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check
More informationRPX Series USER S MANUAL
RPX Series USER S MANUAL INDEX 1.1 Introduction page 1 1.2 Packing page 1 1.3 Drawing page 2~16 1.4 Features page 17 1.5 Specification page 18~21 1.6 Installation & Testing page 22~23 1.7 Hot-Swap Procedures
More informationSeries LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver
Series LCD To power supply Stepper Motor Driver LCD Electric Actuator Series LCC Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationEX-30SERIES. Threaded Miniature Photoelectric Sensor. The next-generation New Form series. A new alternative to fiber sensors. M4(Reflective type: M6)
EX-3SERIES Threaded Miniature Photoelectric The next-generation New Form series. A new alternative to fiber sensors. Marked Conforming to EMC Directive The EX-3 series have a radically new form which has
More informationSwitching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply
Switching Power Supply Compact and Economical Switching Power Supply Models range from 10 to 50 W Open-frame and covered types Wide range of output voltage: 5-, 12-, 15- and 24-V models UL, CSA approved
More informationWALL MOUNTED PANEL. SECTION 2G (Rev.E) SECTION CONTENTS. Download from Technical Manuals area. sec.2g SMYLE WALL-MOUNTED PANEL 2
SECTION G (Rev.E) 8 WALL MOUNTED PANEL 8 Download from www.urmet.com Technical Manuals area. SMYLE WALL-MOUNTED PANEL SECTION CONTENTS SPECIAL MODULES...8 TECHNICAL FEATURES... DOOR UNITS... Door phone
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationPM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs
19 Ultra-small Micro Photoelectric Sensor PM- SERIES Related Information General terms and conditions...p.1 Glossary of terms / General precautions...p.98~ / P.98~ Amplifier Built-in Sensor selection guide...p.11~
More informationVane Type Photoelectric Switches with Self-contained Amplifier
Vane Type Photoelectric Switches with Self-contained Amplifier HPVSeries Switches with 2 optical axes in an easy-to-use size (vane width 2m, depth 3m) save space and reduce wiring. Highly visible indicators
More informationThe dual display means that the current value and the threshold value, it makes direct setting of threshold value
735 Dual Display Digital Pressure Sensor DPC-L100 SERIES SERIES General terms and conditions... F-3 guide... P.699~ Related Information Glossary of terms... P.1563~ General precautions... P.1566 For Liquid
More informationFrom ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets
1147 Detector SERIES Related Information General terms and conditions... F-7 General precautions...p.151 PHOTO PHOTO MEASURE ITY From ultra-thin lead frames to iron sheets... Double feed detection of various
More informationE4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.
Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting
More informationTable of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7
User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7
More informationLong-distance Photoelectric Sensor with Built-in Amplifier. Connection method Sensing distance. --- Retro-reflective. (500 mm) Terminal block ---
Long-distance Photoelectric Sensor with Built-in Amplifier EG CSM_EG_DS_E_ _ Line of Long-distance Photoelectric Sensors for Large Workpieces Includes Retroreflective Models with Sensing Distance of m
More informationFrom ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets
1135 Detector SERIES Related Information General terms and conditions... F-3 General precautions...p.1595 PHOTO PHOTO MEASURE From ultra-thin lead frames to iron sheets... Double feed detection of various
More informationAD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD
AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationGA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability
82 PHOTO PHOTO Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.86~ Sensor selection guide... P.757~ General precautions...
More informationInstallation Guide. Retrofit Kit for USB Ready Intraoral Systems
Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the
More informationGA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations
875 PHOTO PHOTO IT FOW PARTICUAR Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.482~ Sensor selection guide... P.80~
More informationProgramless Controller (With Stroke Study) How to Order
Specialized for Series LEM Programless Controller (With Stroke Study) Series LECP RoHS P LE C P N Controller Compatible motor Step motor (Servo/ VDC) Number of step data (Points) stroke end points/ intermediate
More informationElectronic Balance Ionizer STABLO-AP Service Manual
321-78209 Jan. 2016 Electronic Balance Ionizer STABLO-AP Service Manual Analytical & Measuring Instruments Division This page is intentionally left blank. Table of Contents 1. Precautions for Troubleshooting...
More informationSensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m
Through-Beam Sensor with Visible Red LED Visible Beam Allows Visual Confirmation of the Detection Spot, for Easy Installation and Maintenance Built-in amplifier Mutual interference protection filter included
More informationINSTALLATION INSTRUCTIONS
CONSOLE CONNECTOR KIT 7830 FOR USE WITH: LESLIE Speaker Model 130 Various single and double channel organs INSTALLATION INSTRUCTIONS KIT CONTENT Console Connector 137283 Switch Assembly, Cable Assembly,
More informationREMOVE COVERS. 1. Remove three screws from the Side Panel (L). 2. Slide the Side Panel (L) backward, and raise it to remove from the printer.
REMOVE COVERS 1. Remove three screws from the Side Panel (L). 2. Slide the Side Panel (L) backward, and raise it to remove from the printer. 3. Fully open the Top Cover. 4. Release the tab on the right
More informationTOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004
Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize
More informationonlinecomponents.com
R General-Purpose Fiber-optic Sensor Compact Limit Switch Style with Universal Supply H FET output allows for solid state switching of AC or DC H Universal AC/DC power supply H Choose cable or connector
More informationSERIES. FX-311 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology.
FX-11 SERIES FX-11 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology. Presenting a product which satisfies professionals using volume control. Besides
More informationEE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety
Compact for High-Density Mounting with Easy Snap-In Connector H Connector features a built-in safety lock for shock and vibration resistance H replacement made simple without rewiring H Cables can be bent