1 ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA05 VERSION: 2.9x HEART ENTERPRISE CO. LTD. HEART ENTERPRISE CO., LTD. 0

2 Chapter I Introduction. Introduction 5.2 Features 5. Specification 6. Wiring Assignment 6 Chapter II Installation 2. Terminal block of HA05 descriptions Wring diagram of HA05 to HP506 and Strike power 8 from HP506 internal power supplier 2. Wring diagram of HA05 to HP506 and Strike s 9 power using external power supplier 2. Wring diagram of HA05 to HB02 I/O relay board HA05 networking with HA852C HA05 RS22 interface with HP506 to PC diagram HA05 RS22 interface with HB02 to PC diagram 2.8 HA05 RS85 interface with HP506 to PC diagram HA05 RS85 interface with HB02 to PC diagram Chapter III Main function description. The term of function.. Basic operation..2 Down load parameters from host PC to reader.. Door access modes.. Anti-pass back..5 Anti-duress..6 ARM/DISARM..7 Patrol function..8 Holiday schedule 5 HEART ENTERPRISE CO., LTD.

3 ..9 Time zone 5..0 Invalid card 5.. Sub reader 5..2 Version check 5.. Record and card holders check 5.. Card ID check 6..5 Time and date review 6..6 The program memory checksum review 6.2 Parameter listing 7. Initial setup procedure 8. Parameter setting 8.. Enroll 8..2 Add a new access card 8.. Add a patrol access card 9.. Delete patrol cards 9.5 Password Main password Duress password Guard password 2.5. Date and Time setting 22.6 Timer: All kind of relay time setting Strike active time Alarm active time 2.6. Anti-duress active time 2.6. An interval time of door left open (AJAR) Patrol active time 25.7 System: System parameter setting Tamper alarm enable setting Force entry setting (Enable / Disable) Door not close within a present time alarm 26 (Enable/Disable) HEART ENTERPRISE CO., LTD. 2

4 Alarm relay to be activated when door not closed within 27 a preset time.7.. The D set as NC or NO Mode select Strike mode select DI NO/NC polarity mode selection Polarity of door detector selection (NC/NO) Polarity of emergency button selection (NC/NO) Display ID card number enable System test.7. Communication parameter setting.7.. Address setting.7..2buad rate setting Communication data format setting Recording data check.7... Review transaction data Clear all of record buffer data.7. Other function.7.. Password time zone function enable.7..2 Exit button time zone control enable.7.. Card number free More Access mode time zone setting Anti pass back function enable Anti pass back type A Anti pass back type B Duress functions enable More Main reader type selection Sub reader type selection.7... Main and sub reader switch setting 2 HEART ENTERPRISE CO., LTD.

5 Guard function enables Beeper sound of keys selection (Enable/ Disable).7... Car park functions enable.7.5 Factory default list Chapter IV Error Message. Error / Alarm message 5 HEART ENTERPRISE CO., LTD.

6 CHAPTER I INTRODUCTION. INTRODUCTION HA05 is a single door controller built-in a proximity reader and connect an external reader for exit reader. Basically HA05 dedicated design for small and medium size companies its access control, time attendance, car park and patrol system. It function including on-line and stand-alone operating structure in one unit that is easy for installer to keep stock and maintain. The whole system is connecting up to 99 units of HA05 via RS85 interface at on-line operation mode. And HA05 has to operate with PC software to download cardholder with parameters and upload all of even data for management..2 FEATURES. Proximity type reader EM or HID or Mirfare format option, read range up to 0cm(Mirfare read range up to 5 cm only) 2. On line and stand-alone mode selectable.. Memory capacity stored up to,000 cardholders and,500 transactions. Reordering data 90% full indication.. Communication interface RS22c for single unit of HA05 and RS85 for networking configuration. 5. Communication baud rate and reader address can be programmed via keypad. 6. System networking up to 99 units of HA05 through RS85 interfaces control. 7. System program stored in Flash Memory upgrading by PC program down load and no more changes EPROM chip 8. Master and slave reader connected with HID reader or HR0 EM standard WIEGAND format reader. 9. Door AJAR alarm available. 0. Patrols function available.. Guard function ARM/DISARM available. 2. Car park function available.. Exit button available.. Force entry alarm function available. 5. Tamper alarm function available. 6. Emergency alarm function available. 7. Card holder data and all of reader parameter down load and up load by ACS05 software 8. LCD display,6 characters 2 lines with back light. 9. Access mode function available. 20. Door access model selectable. (). Card data (2). Card data + password personal password (PIN) or main password (). Press Card ID data 2. Anti-duress function available 22. Anti-pass back type A/B function available 2. Whole year calendars schedule for holiday control available 2. 0 time zone available including personal password time zone, push button time zone, access mode time zone and door AJAR time zone control HEART ENTERPRISE CO., LTD. 5

7 25. Up to 2 months battery back up capacity for data storage during power failure. 26. With power saver function, the backlight of LCD display turns off once there is operation within minutes. 27. Card data enrollment functions without networking operation. 28. Audible key tone available 29. Serial printer interface support to print transaction data and cardholder data and all of parameter. 0. Strike, alarm and duress relay drive time selectable (-255 ). Strike active latch and momentary mode selectable. 2. Door left open time selectable (-255 ). Two-piece enclosure design the reader is patted for weather and hazard proofing. A separate relay module design, high urity provided 5. Eight error message available (all records are stored in controlled software). SPECIFICATION Reader range Up to 0cm (EM ISO-chip card 25 KHZ) Display 6 characters * 2 lines LCD with back light Keypad 2 key (0-9, *, #) Memory Buffer 28Kbyte SRAM sorted,000 card holders and,500 transactions based on 8 digits Indicator Bi-color LED (Green/Red) Communication interface RS22c and RS85 Case Material ABS (UL 9V-0) Dimension 50 (H) * 0 (W) * 5 (D) mm Weight 80 g Working voltage DC 0-5 volts Power Consumption 00mA MAX Operating temperature 0 ~50 Humidity 5 ~95 (condensation) Approved IEC 529 IP, CE. WIRING ASSIGNMENT Color Name Description Red V+ +2VDC input from Controller Black GND Ground Brown CLK Clock signal to Controller Orange DATA Data Signal to Controller Yellow ACP AC Power failure input acknowledge from Controller. If your system wiring to HB02 no use in this line. Green T-/TXD For RS85 T- or RS22 TXD Blue T+/RXD For RS85 T+ or RS22 RXD Violet DATA For sub-reader WIEGAND data input Gray DATA0 For sub-reader WIEGAND data0 input White LED For sub-reader LED indication HEART ENTERPRISE CO., LTD. 6

8 CHAPTER II INSTALLATION 2. Terminal block of HP506 descriptions. Block number Name Description T V+ +2V DC output for master reader T2 GND Ground T Exit button Door release exit button NO T & T6 active T Door sensor Door status NC/NO defined by controller, T & T6 active T5 Aux sensor For emergency detection NC/NO defined by controller, T5 & T6 active T6 GND Ground T7 Strike COM Door electrical strike output, relay contact 0A/2Vdc. Normally this block connected to T +2Vdc supply electrical strike power and NC or NO active depend upon strike type. For example the bolt type strike & EM look normally NC active and electrical strike normally NO active. T8 Strike NC Electrical strike NC loop control T9 Strike NO Electrical strike NC loop control T0 Alarm COM Alarm output, relay contact A/2Vdc. Normally this block connected to T+2Vdc power supply and go through T2 to siren. T Alarm NC Alarm NC active loop. T2 Alarm NO Alarm NO active loop. T Duress COM Duress alarm output, relay contact A/2Vdc. Normally this block and T5 are dry contact to Central Station System. T Duress NC Duress NC active loop T5 Duress NO Duress NO active loop T6 Guard COM Guard alarm output, relay contact A/2Vdc. Normally this block and T7 are dry contact to Alarm system for ARM/DISARM control. T7 Guard NC Guard NC active loop T8 Guard NO Guard NO active loop T9 Patrol COM Patrol status output, relay contact A/2Vdc. Normally this block and T2 are dry contact to Guard Tour System. T20 Patrol NC Patrol NC active loop T2 Patrol NO Patrol NO active loop NOTICE:. Connecting a diode on electrical bolt or strike coil. 2. If the door strikes using external power supplier which strong recommend HEART ENTERPRISE CO., LTD. 7

9 grounding together with HP506.. If the door strikes using AC power source please using MOV to instead of diode. 2.2 Wiring diagram of HA05 to HP506 and Strike power from HP506 internal power supplier. DIODE + PT EL A Alarm Siren Coil Elecric Bolt +2VDC GND Push Button Door Sensor Aux Sensor GND Strike COM Strike NC Strike NO Alarm COM Alarm NC Alarm NO Duress COM Duress NC Duress NO Guard COM Guard NC Guard NO Patrol COM Patrol NC Patrol NO T T2 T T T5 T6 T7 T8 T9 T0 T T2 T T T5 T6 T7 T8 T9 T20 T2 K K2 K K K5 HA020 SERIES ACCESS CONTROL SYSTEM RED V+ BLACK GND BROWN CLK ORANGE DATA YELLOW ACP RED BLACK BROWN ORANGE YELLOW J 2 5 HP506 WIRING DIAGRAM In general, fix the power pack at the top of the door ceiling. Connect the main unit and power pack with a five-conductor strand, distant not larger then 50 meter. HEART ENTERPRISE CO., LTD. 8

10 2. Wring diagram of HA05 to HP506 and the Strike s power using external power supplier AC 2V Coil AC Strike Convert Relay Diode Alarm Siren +2VDC GND Push Button Door Sensor Aux Sensor GND Strike COM Strike NC Strike NO Alarm COM Alarm NC Alarm NO Duress COM Duress NC Duress NO Guard COM Guard NC Guard NO Patrol COM Patrol NC Patrol NO T T2 T T T5 T6 T7 T8 T9 T0 T T2 T T T5 T6 T7 T8 T9 T20 T2 K K2 K K K5 AC LOAD WIRING SCHEMATIC 2. Wring diagram of HA05 to HB02 I/O relay board RED BLACK BROWN ORANGE V GND INPUT DC 2V CLOCK DATA EXIT BUTTON DOOR SENSOR STRIKE ALARM HB02 K VDC +2VDC ALARM SIREN +2VDC GND PUSH BUTTON DIODE + A EL Coil PT HA020 SERIES ACCESS CONTROL SYSTEM HB02 STRUCTURE DIAGRAM Bolt HEART ENTERPRISE CO., LTD. 9

11 2.5 HA05 networking with HA852C System networking up to 6 units of HA05 through HA852c RS85 interfaces converter, Basically HA05 can be connected 99 units together in three RS85 buses. One of each bus has 2 sets in,000 meters distance TO MODEM COM PORT MODEM External MODEM HA05 # TO #2 SETS RS22 RS85 TO HOST PC RS22 PORT 0P WIRE P WIRE Blue Green Blue Green Blue Green HA05 # TO #6 SETS RS85 DATA BUS HA852C SYSTEM WIRING DIAGRAM RS85 DATA BUS 2 Red Black 0P WIRE Blue Green 0P WIRE Blue Green 2.6 HA05 RS22 interface with HP506 to PC diagram If your system will connect to PC RS22 directly that its means your system has one of reader so you have to adjust jumper to under position. RS85 RS22 NOTICE: In order to protect the connected equipment, please consult the technical people before adjust these following function. HEART ENTERPRISE CO., LTD. 0

12 RED BLACK BROWN ORANGE YELLOW V+ GND CLK DATA ACP RED BLACK BROWN ORANGE YELLOW 2 5 HP506 HA05 GREEN TR- BLUE TR+ VIOLET DATA GRAY DATA0 WHITE LED 5 GREEN BLUE 2 6 PC RS22 RED BLACK WHITE GREEN GRAY HR0 HA05+HP506 TO PC RS22 AND HR0 WIRING DIAGRAM 2.7 HA05 RS22 interface with HB02 to PC diagram RED BLACK BROWN ORANGE YELLOW V+ GND CLK DATA ACP RED BLACK BROWN ORANGE 2 HB02 HA05 GREEN BLUE VIOLET GRAY WHITE TR- TR+ DATA DATA0 LED 5 GREEN BLUE 2 6 PC RS22 RED BLACK WHITE GREEN GRAY HR0 HA05+HB02 TO PC RS22 AND HR0 WIRING DIAGRAM HEART ENTERPRISE CO., LTD.

13 2.8 HA05 RS85 interface with HP506 to PC diagram The default setting of communication interface of HA05 is RS85 so any of installation not needs to screw out PCB to select J and J2. Basically J and J2 are setting like as follow position. RS85 RS22 NOTICE: In order to protect the connected equipment, please consult the technical people before adjust these following function. RED BLACK BROWN ORANGE YELLOW V+ GND CLK DATA ACP RED BLACK BROWN ORANGE YELLOW 2 5 HP506 HA05 GREEN BLUE VIOLET GRAY WHITE TR- TR+ DATA DATA0 LED 5 GREEN BLUE 2 6 HA852C RED BLACK WHITE GREEN GRAY HR0 HA05+HP506 TO HA852C AND HR0 WIRING DIAGRAM 2.9 HA05 RS85 interface with HB02 to PC diagram HEART ENTERPRISE CO., LTD. 2

14 RED BLACK BROWN ORANGE YELLOW V+ GND CLK DATA ACP RED BLACK BROWN ORANGE 2 HB02 HA05 GREEN BLUE VIOLET GRAY WHITE TR- TR+ DATA DATA0 LED 5 GREEN BLUE 2 6 HA852C RED BLACK WHITE GREEN GRAY HR0 HA05+HB02 TO HA852C AND HR0 WIRING DIAGRAM HEART ENTERPRISE CO., LTD.

15 Chapter III MAIN FUNCTION DESCRIPTION. The term of function... Basic operation HA05 system use non-contact, proximity RF technology, just present the proximity card approach the main unit to access the door. Any of proximity cards present to the reader will record its events into memory buffer and retrieved back to host by PC program...2.down load parameters from host PC to reader HA05 is on line type access control all of cardholders and some of parameters are settled by PC application program.... Door access modes: three door access modes selectable: () Card data only --- place the card approach the main unit to access the door. (2) Card data or with main password or personal password --- place the card approach the main unit AND then key-in the main password or personal password to access the door. () Card data or main password --- place the card approach the main password to access the door.... Anti-pass back Normally anti-pass back function used in car park system. And now some of offices have highly urity restricted area control need to define with the anti-pass back function. That means you have to hold your proximity card in/out the gate or door. If any once of you go through the gate did not present the card next time not allow you come in again. So in the anti-pass back mode you have to present you card whatever in or out of the gate. This even will record into HA05 transaction memory buffer...5. Anti-duress With the anti-duress function provided, you no longer kidnap by thief. Key-in a preset code to the rear of the regular password with 9, the duress relay will be activated to drive the require device, other then the door opened normally and this even will record into HA05 transaction memory buffer...6. ARM/DISARM HA05 equipped a guard relay, which can arm or disarm the connected urity system. Use guard password or guard password plus card data to activate this function, and guard password or regular access procedure to deactivate this function and this even will record into HA05 transaction memory buffer...7. Patrol function This function provides the facility to monitor the watchman who patrols a certain district. HA05 equipped a patrol a relay which can activated the connected recording system, you cannot access the door neither use the patrol card or HEART ENTERPRISE CO., LTD.

16 patrol password and this even will record into HA05 transaction memory buffer..8. Holiday schedule Holiday schedule is one of main functions of HA05. Holiday schedule is for user s defined which date available to access the door. HA05 will refer preset 2 months schedule and control user who can access the door. If user s database not allows enter in holiday HA05 will automatically deny access when you present cards. This even will record into HA05 transaction memory buffer...9. Time zone Time zone means user what time can be accessed the door. HA05 have 0 time zone can be preset and any ID have one of time zone parameter can be selected. That is every time you present your card HA05 will check and verify ID, Holiday and Time zone met with preset parameter. This even will record into HA05 transaction memory buffer...0. Invalid card That means this ID card not available or format unmatched. This even will record into HA05 transaction memory buffer....sub reader HA05 can be connected with HR0 or HID 26 bits WIEGAND reader or other brand WIEGAND reader for exit readers. This even will record into HA05 transaction memory buffer...2. Version check You can see the version/type, device number and communication BUAD rate. Check Version Default Display Time and Date will change PRESS 0 HA05 V: 2.60 ADDR:0 B: 9600 Release keypad 2002/06/0 2:0... Record and card holders check You can see the enrolled card amount of card reader and the number of record stored at present. Record and card holder check Default Display Time and Date will change HEART ENTERPRISE CO., LTD. 5

17 PRESS 2 RECORD: CARD_H: 0 Release keypad... Card ID check You can check the ID code of your card. 2002/06/0 2:0 Record and card holder check Default Display Time and Date will change PRESS CARD PLEASE Or time out in /06/0 2:0..5. Time and date review You can see the ond of the built-in real time clock for the purpose of setting by ACS05 software. Record and card holder check Default Display Time and Date will change 06/0 2:00:00 06/0 2:00:0 06/0 2:00:02 Release keypad HEART ENTERPRISE CO., LTD. 6

18 .2 PARAMETER LISTING The hierarchy diagram shows the relationship of each function Main function Function Function 2 Function Function Function 5.ENROL.ACCESS CARD 2.PATROL CARD.CRAD_ ENROL 2.CARD_DELETE 2.PASSWD.MAIN 2.DURESS.GUARD.CLOCK.TIMER.SYSTEM.STRIKE 2.ALARM.DURESS.DOOR 5.PATROL.ALARM 2MODE.COMM.OTHER.DATE_SETTING 2.TIME_SETTING.TAMPER 2.FORCE.D-OPEN.EMGCY.STRIKE 2.DI.DISP.TEST 5.OP_MODE.ADDRESS 2.BAUD.FORMAT.RECO..P_ZONE 2.E_ZONE C_FREE.MORE.FUNCTION 2.K2 ACTIVE.EXIT BUTTON 2.DOOR.DI_.REVIEW 2.CLEAR.RECORD_BU FFER.WHOLE SYSTEM 2.PARTIAL.A_ZONE.ACCESS ZONE HEART ENTERPRISE CO., LTD. 7

19 2.ANTI_P.DURESS.MORE 2.ACCESS ZONE 2.FUNCTION 2.TYPE.READER 2.GUARD.TONE.PARK.MAIN 2.SUB.SWAP. INITIAL SET UP PROCEDURE. HP506 power on wiring to HA05 2. Lock settle down. HA05 address setting. HA05 BUAD setting 5. Enrolled test card 6. PC software linking test 7. Set up. PARAMETER SETTING. ENROL 2. PASSWD. TIMER. SYSTEM.. ENROL: Card data enrollment. ACCESS CARD 2. PATROL CARD Only the authorized card to be permitted to access the door all new cards should be enrolled before used or down load from HOST PC software. There are two categories: the access card which to be used to access the door, up to 000 cards can be stored and put into operation; the patrol card use to monitor the watchmen who patrol a certain district...2 Add a new access card The following example assume the master code as "" (factory default) and no card data in the memory. Enroll access card Default Display DC POWER ON HEART ENTERPRISE CO., LTD. 8

20 PRESS PASSWORD: PRESS #.ENROLL 2.PASSWD..TIMER.SYSTEM PRESS.ACCESS CARD 2.PATROL CARD AMOUNT :0 CARD NO.: Present proximity AMOUNT: card CARD NO.: Or time out in 5 Default master code.. Add a patrol access card This example assume the master code as "" (factory default) and zero card data in the memory: Enroll patrol card Default Display DC POWER ON PRESS PASSWORD: PRESS #.ENROLL 2.PASSWD..TIMER.SYSTEM PRESS.ACCESS CARD 2.PATROL CARD PRESS 2.CARD_ENROL 2.CARD_DELETE AMOUNT :0 CARD NO.: Present proximity AMOUNT: card CARD NO.: Or time out in 5 Default master code.. Delete patrol cards The following example assume the master code as ""(factory default) Delete patrol card Default Display DC POWER ON HEART ENTERPRISE CO., LTD. 9

21 PRESS PASSWORD: PRESS #.ENROLL 2.PASSWD. Default master PRESS.ACCESS CARD 2.PATROL CARD PRESS 2.CARD_ENROL 2.CARD_DELETE PRESS 2 AMOUNT: CARD NO.: Present proximity AMOUNT :0 card Or time out in 5.5 PASSWD: Password setting. MAIN 2. DURESS. GUARD. CLOCK CARD NO.:.5. Main password The main password ( digits) used as a access code to access the door during the ond (card data plus password) access mode default is ", you can change the code through the following procedure: Main password Default Display DC POWER ON PRESS PASSWORD: PRESS #.ENROLL 2.PASSWD..TIMER.SYSTEM PRESS 2.MAIN 2.DURESS..GUARD.CLOCK CURRENT: NEW: PRESS 2 CURRENT: NEW: Or time out in 5 Default master code.5.2 Duress password The duress password ( digits) can be used to activated the equipped duress HEART ENTERPRISE CO., LTD. 20

22 relay factory default is " 9, you can change the code through the following procedure: Duress password Default Display DC POWER ON PRESS PASSWORD: PRESS #.ENROLL 2.PASSWD..TIMER.SYSTEM PRESS 2.MAIN 2.DURESS..GUARD.CLOCK PRESS 2 CURRENT: 9 NEW: PRESS 2 CURRENT: 9 NEW: Or time out in 5 Default master code.5. Guard password The Guard password ( digits) can be bused to arm or disarm the connected urity system, factory default is "2" you can changed the code through the following procedure: Duress password Default Display DC POWER ON PRESS PASSWORD: PRESS #.ENROLL 2.PASSWD..TIMER.SYSTEM PRESS 2.MAIN 2.DURESS..GUARD.CLOCK PRESS CURRENT: 9 NEW: PRESS 2 CURRENT: 9 NEW: Or time out in 5 Default master code HEART ENTERPRISE CO., LTD. 2

23 .5. Date and Time setting The CLOCK function for hardware date and time adjustment: DATE adjustment Default Display DC POWER ON PRESS PASSWORD: PRESS #.ENROLL 2.PASSWD..TIMER.SYSTEM PRESS 2.MAIN 2.DURESS..GUARD.CLOCK PRESS.DATE_SETTING 2.TIME_SETTING DATE: 2002/06/0 Press # OK Default master code TIME adjustment Default Display PRESS PASSWORD: PRESS #.ENROLL 2.PASSWD..TIMER.SYSTEM PRESS 2.MAIN 2.DURESS..GUARD.CLOCK PRESS.DATE_SETTING 2.TIME_SETTING PRESS 2 DATE: 2002/06/0 Press # OK DC POWER ON Default master code.6 TIMER: All kind of relay time setting. STRIKE 2. ALARM. DURESS. DOOR NOTICE: In order to protect the connected equipment, please consult the technical people before adjust these following function..6. Strike active time This relay connected to the electric once somebody accesses the door. The active time depends on the characteristic of the strike. HEART ENTERPRISE CO., LTD. 22

24 Please consult the technical people before adjust the relay time: Strike time setting Default Display DC POWER ON PRESS PASSWORD: PRESS # PRESS PRESS 0# Or time out in 5.ENROLL 2.PASSWD..TIMER.SYSTEM.STRIKE 2.ALARM.DURESS.DOOR CURRENT: 5 SEC NEW: CURRENT: 5 SEC NEW: 0 CURRENT: 0 SEC NEW: Default master code.6.2 Alarm active time The alarm relay can be activated by the following event:. Front panel destroyed by vandal 2. Forced entry. Door opened over the preset time Please consult the technical people before adjust the relay time: Alarm time setting Default Display DC POWER ON PRESS PASSWORD: PRESS # PRESS PRESS 2 PRESS 0#.ENROLL 2.PASSWD..TIMER.SYSTEM.STRIKE 2.ALARM.DURESS.DOOR CURRENT: 5 SEC NEW: CURRENT: 5 SEC NEW: 0 CURRENT: 0 SEC NEW: Default master code HEART ENTERPRISE CO., LTD. 2

25 Or time out in 5.6. Anti-duress active time In general this relay connected to the alarm system, which for away the scene, For example, the building management office, police, station. Etc. Please consult the technical people before adjust the relay time: Anti-duress active Default Display DC POWER ON time delay PRESS PASSWORD: PRESS # PRESS PRESS PRESS 0# Or time out in 5.ENROLL 2.PASSWD. Default master.strike 2.ALARM.DURESS.DOOR CURRENT: 5 SEC NEW: CURRENT: 5 SEC NEW: 0 CURRENT: 0 SEC NEW:.6. An interval time of door left open (AJAR) In general, the door could be closed within a preset time; otherwise the alarm system will be activated. Please consult the technical people before adjust the relay time. Door left open Default Display DC POWER ON alarm time setting PRESS PASSWORD: PRESS # PRESS.ENROLL 2.PASSWD. Default master.strike 2.ALARM.DURESS.DOOR HEART ENTERPRISE CO., LTD. 2

26 PRESS PRESS 0# Or time out in 5 CURRENT: 5 SEC NEW: CURRENT: 5 SEC NEW: 0 CURRENT: 0 SEC NEW:.6.5 Patrol active time This relay connected to the monitoring system or some of alarm system. Please consult the technical people before adjust the relay time: Patrol time setting Default Display DC POWER ON CHECK VERSION. PRESS PASSWORD: PRESS # PRESS PRESS 5 PRESS 0# Or time out in 5.ENROLL 2.PASSWD..TIMER.SYSTEM.STRIKE 2.ALARM.DURESS.DOOR CURRENT: 5 SEC NEW: CURRENT: 5 SEC NEW: 0 CURRENT: 0 SEC NEW: Default master code.7 SYSTEM: System parameter setting. ALARM 2. MODE. COMM. OTHER.7.. Tamper alarm enable setting HA05 equipped a tamper switch for vandal resistance, use the following procedures to Enable this function if require: HEART ENTERPRISE CO., LTD. 25

27 Tamper alarm enable setting Default Display PRESS PASSWORD: DC POWER ON PRESS # PRESS Or time out in 5.ENROLL 2.PASSWD. Default master.alarm 2.MODE.COMM.OTHER.TAMPER 2.FORCE.D_OPEN CURRENT: DISABLE CURRENT: ENABLE.7..2 Force entry setting (Enable / Disable) The alarm will be activated when entry by force without regular access, card data or password, use the following procedures to enable this function if require: Force entry enable Default Display DC POWER ON setting PRESS PASSWORD: PRESS # PRESS PRESS 2 Or time out in 5.ENROLL 2.PASSWD..TIMER.SYSTEM.ALARM 2.MODE.COMM.OTHER.TAMPER 2.FORCE.D_OPEN CURRENT: DISABLE CURRENT: ENABLE Default master code.7... Door not close within a present time alarm (Enable/Disable) The alarm will be activated when the door could not close within a preset time, HEART ENTERPRISE CO., LTD. 26

28 use the following procedures to Enable this function if require. AJAR function Default Display DC POWER ON enable setting PRESS PASSWORD: PRESS # PRESS PRESS Or time out in 5.ENROLL 2.PASSWD. Default master.alarm 2.MODE.COMM.OTHER.TAMPER 2.FORCE.D_OPEN.FUNCTION 2.K2 ACTIVE CURRENT: DISABLE CURRENT: ENABLE Alarm relay to be activated when door not closed within a preset time The built-in buzzer will activate. Enable this function in if external alarm is required. AJAR relay enable Default Display DC POWER ON setting PRESS PASSWORD: PRESS # PRESS PRESS PRESS 2.ENROL Default master 2.PASSWD. code.timer.system.alarm 2.MODE.COMM.OTHER.TAMPER 2.FORCE.D_OPEN.FUNCTION 2.K2 ACTIVE CURRENT: DISABLE HEART ENTERPRISE CO., LTD. 27

29 Or time out in 5 CURRENT: ENABLE.7.. The D set as NC or NO loop emergency function to be activated and enable this function is required. AJAR relay enable Default Display DC POWER ON setting PRESS PASSWORD:.7.2 Mode select. STRIKE 2. DI. DISP. TEST 5. OP_MODE PRESS # PRESS PRESS Or time out in 5.CARD 2.PASSWD..TIMER.SYSTEM.ALARM 2.MODE.COMM.OTHER.TAMPER 2.FORCE.D_OPEN.EMGCY CURRENT: DISABLE CURRENT: ENABLE Default master code.7.2. Strike mode select HA05 strike usually output mode is Momentary. May be some of output load having to work as Latch mode, so HA05 can be selected output mode to define strike relay. Change card Default Display DC POWER ON format HEART ENTERPRISE CO., LTD. 28

30 PRESS # PRESS 2 Or time out in 5.ENROL 2.PASSWD..TIMER.SYSTEM.ALARM 2.MODE.STRIKE 2. DI.DISP.TEST STRIKE: MOMENTARY STRIKE: LATCH Default master code DI NO/NC polarity mode selection HA05 has three-di mode selection. Exit button 2. Door sensor. Emergency button The polarity of these point can be changed when require ( NO normal open ; NC normal close ) Exit button active Default Display DC POWER ON NO to NC PRESS #.ENROL 2.PASSWD. Default master.alarm 2.MODE PRESS 2.STRIKE 2. DI.DISP.TEST PRESS 2.EXIT BUTTON 2.DOOR.DI_ CURRENT: NO Default NO CURRENT: NC Or time out in Polarity of door detector selection (NC/NO) The following example assume the master code as door detector point as NO state (factory default) HEART ENTERPRISE CO., LTD. 29

31 Exit button active NO to NC Default Display DC POWER ON PRESS #.ENROL 2.PASSWD. Default master.alarm 2.MODE PRESS 2.STRIKE 2. DI.DISP.TEST PRESS 2.EXIT BUTTON 2.DOOR.DI_ PRESS 2 CURRENT: NO Default NO CURRENT: NC Or time out in Polarity of emergency button selection (NC/NO) The following example assume the master code as emergency button as NO state (factory default): Exit button active Default Display DC POWER ON NO to NC PRESS #.ENROL 2.PASSWD. Default master.alarm 2.MODE PRESS 2.STRIKE 2. DI.DISP.TEST PRESS 2.EXIT BUTTON 2.DOOR.DI_ PRESS CURRENT: NO Default NO CURRENT: NC Or time out in Display ID card number enable This function for user to see ID number when you present proximity card. HEART ENTERPRISE CO., LTD. 0

32 Display ID card number enable Default Display DC POWER ON PRESS # PRESS 2 PRESS Or time out in 5.ENROL 2.PASSWD. Default master.alarm 2.MODE.STRIKE 2. DI.DISP.TEST CURRENT: DISABLE CURRENT: ENABLE.7.2. System test NOTICE: In order to protect the connected equipment, please consult the technical people before adjust these following function This function for engineer tests HA05 in production line or maintain. After operation this function will clear all of memory data including cardholders and transaction data. So strong recommend any of users please DO NOT operate this function..7. Communication parameter setting. ADDRESS 2. BAUD. FORMAT. RECO NOTICE: In order to protect the connected equipment, please consult the technical people before adjust these following function This function for engineer set up HA05 communication parameters. So strong recommend any of users please DO NOT operate this function..7.. Address setting Address means HA05 machinery number its from 0 to 99. Address setting Default Display DC POWER ON PRESS #.ENROLL 2.PASSWD. Default master HEART ENTERPRISE CO., LTD.

33 .ALARM 2.MODE PRESS.ADDRESS 2. BUAD.FORMAT.RECO ADDRESS:0 NEW: PRESS 02 ADDRESS:0 NEW:02 ADDRESS:02 NEW: Or time out in BUAD rate setting HA05 communication speed rate setting from 9600 to 9200 bps and default value is 9600bps. BUAD rate setting Default Display DC POWER ON PRESS # PRESS.ENROLL 2.PASSWD Default master.alarm 2.MODE.ADDRESS 2. BUAD.FORMAT.RECO PRESS 2 BUAD RATE: 9600 BUAD RATE: 9200 Or time out in Communication data format setting Default data format is o, 7,. It means ODD parity and 7 bits data and stop bit. HA05 offer types of data format are o, 7, and n, 8, and n, 8,2. The n, 8, means no parity and 8 bits data and stop. Data format Default Display DC POWER ON setting PRESS #.ENROLL 2.PASSWD. Default master HEART ENTERPRISE CO., LTD. 2

34 .ALARM 2.MODE PRESS.ADDRESS 2. BUAD.FORMAT.RECO PRESS CURRENT: O, 7, CURRENT: N, 8, Or time out in Recording data check NOTICE: In order to protect the connected equipment, please consult the technical people before adjust these following function.7... Review transaction data This function is for review HA05 clocking data off line operation. Review Default Display DC POWER ON transaction data PRESS #.ENROLL 2.PASSWD. Default master.alarm 2.MODE PRESS.ADDRESS 2. BUAD.FORMAT.RECO PRESS.REVIEW 2.CLEAR.RECORD_BUFFER Press means forward PRESS Press 2 means revert Clear all of record buffer data NOTICE: In order to protect the connected equipment, please consult the technical people before adjust these following function This function is for engineer testing HA05 in production line or maintain. After operation this function will clear all of memory data including cardholders and transaction data. So strong recommend any of users please DO NOT operate this function..7. Other function HEART ENTERPRISE CO., LTD.

35 . P_ZONE 2. E_ZONE. C_FREE. MORE.7.. Password time zone function enable It is used to set if you would like to launch [P_ZONE] function. If user input personal password in the password column while enrolling the card, users need to key in personal password to open door. However, user may pre-set a password to use at a time zone if user enables [P_ZONE] function. When it is holidays or within the range of the above time zone, user must key in the pre-set password to open door. While, open door by card will do at other time. For instance, user can instruct the card reader to open door without the need to type in password at day time and with the need to type in password at holidays and night time. User can also set this through the application. Password time Default Display DC POWER ON zone enable PRESS #.ENROLL 2.PASSWD. Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE CURRENT: DISABLE CURRENT: ENABLE Or time out in Exit button time zone control enable It is used to set whether to launch [E_ZONE] function. Usually, at any time press [Exit Button] can open door. But if launching the [P_ZONE] function, user can pre-set an available time zone for [E_ZONE]. User needs to press [Exit Button] to open door within the above pre-set time zone. The [Exit Button] will not have function to open door when pressed at other time and holidays. User can setup this item through the application. Exit button time Default Display DC POWER ON zone enable HEART ENTERPRISE CO., LTD.

36 PRESS # PRESS 2 Or time out in 5.ENROLL 2.PASSWD..TIMER.SYSTEM.ALARM 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE CURRENT: DISABLE CURRENT: ENABLE Default master code.7.. Card number free User can select if all the card numbers or specific card numbers can simply input the card number into card reader to open door. Specific card number means the first four digit of the card number are 0 such as Enrolled card number uses it to set if every cardholder could open door. The default setting is disabled. User can setup this item through the application. Whole system Default Display DC POWER ON card number use enable PRESS #.ENROLL 2.PASSWD. Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE PRESS.WHOLE SYSTEM 2.PARTIAL CURRENT: DISABLE CURRENT: ENABLE Or time out in 5 It is used to set if specific cardholders can open door by inputting card number. The default setting is disabled. HEART ENTERPRISE CO., LTD. 5

37 Partial system card number use enable.7.. More. A_ZONE 2. ANTI_P. DURESS. MORE Default Display DC POWER ON PRESS # PRESS PRESS 2 Or time out in 5.ENROLL 2.PASSWD..TIMER.SYSTEM.ALARM 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.WHOLE SYSTEM 2.PARTIAL CURRENT: DISABLE CURRENT: ENABLE Default master code.7... Access mode time zone setting The Time Zone 6 and Time zone 7 of HA05 card reader can be used to be temporary unrestricted time zone. Within the range of the two time zones, the relay of electronic lock will be automatically energized to release the lock and let people go in and out freely. But when it is holiday, the function will be automatically invalid. Time Zone 7 is ACCESS ZONE. TZ6 is ACCESS ZONE 2. User can set the function as Enable/Disable in HA05 card reader. (The default setting is Disable) It is used to set if enable [ACCESS ZONE ]. The default setting is disabled. Access mode Default Display DC POWER ON zone enable PRESS #.ENROLL 2.PASSWD. Default master HEART ENTERPRISE CO., LTD. 6

38 .ALARM 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE PRESS.ACCESS ZONE 2.ACCESS ZONE 2 CURRENT: DISABLE CURRENT: ENABLE Or time out in 5 It is used to set if enable [ACCESS ZONE 2]. The default setting is disabled. Access mode Default Display DC POWER ON zone enable PRESS #.ENROLL 2.PASSWD. Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE PRESS.ACCESS ZONE 2.ACCESS ZONE 2 PRESS 2 CURRENT: DISABLE CURRENT: ENABLE Or time out in Anti pass back function enable This function should be used in conjunction with ond reader for exit. Anti-Pass back can be divided into two kinds of control types: It is used to set if enable [ANTI_P Function]. The default setting is disabled. It is used to use which control mode of ANTI_ P type. The default setting is [TYPE_A]. HEART ENTERPRISE CO., LTD. 7

39 Anti pass back function enable Default Display DC POWER ON PRESS # PRESS 2 Or time out in Anti pass back type A.ENROLL 2.PASSWD. Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE.FUNCTION 2.TYPE CURRENT: DISABLE CURRENT: ENABLE Only the entering will be controlled under this type. (The default control mode). User cannot use the same card number on the same card reader to open door after using the card number to open door, until user uses ond reader to exit. Nevertheless, the restriction dose not includes using ond reader to exit. Anti pass back Default Display DC POWER ON function enable PRESS #.ENROLL 2.PASSWD. Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE PRESS 2.FUNCTION 2.TYPE HEART ENTERPRISE CO., LTD. 8

40 PRESS 2 Or time out in 5 CURRENT: TYPE_A CURRENT: TYPE_B Anti pass back type B The exit and entering will be controlled under this control mode. User cannot use the same card number on the same card reader to open door after using the card number to open door, until user uses ond reader to exit. Likewise, the number cannot exit by using ond reader to open door if the number has not been used to open door use ond reader to exit. When computer downloads the card information anew to card reader or enrolls the card information in the card reader again. The flag of Anti-Pass back will be reset to allow of entering. Anti pass back Default Display DC POWER ON type selection PRESS #.ENROLL 2.PASSWD. Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE PRESS 2.FUNCTION 2.TYPE PRESS 2 CURRENT: TYPE_A CURRENT: TYPE_B Or time out in Duress functions enable It is used to set if enable [Duress] function. The default setting is disabled. If the function is enabled, user can first input duress password and then conduct card reading. If the Duress function is set to be enabled, user can first input the duress password and then conduct the card reading procedure when forced to open door. Door will be opened as usual; meanwhile, trigger another duress relays to notify the urity guards. The default duress password is 9 ( digits) and alterable. HEART ENTERPRISE CO., LTD. 9

41 Duress function enable Default Display DC POWER ON PRESS # PRESS Or time out in 5.ENROLL 2.PASSWD..TIMER.SYSTEM.ALARM 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE.FUNCTION 2.TYPE CURRENT: DISABLE CURRENT: ENABLE Default master code.7... More. READER 2. GUARD. TONE. PARK Main reader type selection HA05 card reader may connect an exterior ondary reader except a built-in inductive main reader. No matter the main or ondary reader it is, user can choose from the reader types of RM07 HID 26Bits or HR0 26Bits. The default main reader type is RM07 and ondary reader is HR0. The pre-set main reader is usually for the use of entering and the ondary reader for the use of exit. However, the role of main and ondary readers can be swapped It is used to set the model of built-in inductive main reader of HA05. The default setting is RM07. Main reader type Default Display DC POWER ON selection PRESS #.ENROLL 2.PASSWD Default master HEART ENTERPRISE CO., LTD. 0

42 .ALARM 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE.READER2. GUARD.TONE.PARK PRESS.MAIN 2. SUB.SWAP CURRENT: RM07 CURRENT: HID CURRENT: HR0 CURRENT: RM07 Or time out in Sub reader type selection It is used to set the model of the exterior ondary reader of HA05. The default model of exterior ondary reader is HR0. Sub reader type Default Display DC POWER ON selection PRESS #.ENROLL 2.PASSWD. Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE.READER2. GUARD.TONE.PARK PRESS.MAIN 2. SUB.SWAP PRESS 2 CURRENT: RM07 CURRENT: HID HEART ENTERPRISE CO., LTD.

43 Or time out in 5 CURRENT: HR0 CURRENT: RM Main and sub reader switch setting It is used to set if sway the role between main and ondary readers as the reader of exit or of entering. The default setting is NO, not swap. Main and sub Default Display DC POWER ON reader switch setting PRESS #.ENROLL 2.PASSWD. Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE.READER2. GUARD.TONE.PARK PRESS.MAIN 2. SUB.SWAP PRESS CURRENT: NO CURRENT: YES Or time out in Guard function enables It is used to set if enable Guard function. The default setting is disabled. If enable [Guard] function, user can first input the correct guard password and then do the door open procedure to enable/disable the actions of Guard function. Under the status of Guard-enabled, card reader will not allow door open operation except that user press emergency button, exit button or order through computer. Disabling Guard function will further make door open. When under the status of guard-enable the anti-force alarm will enable automatically. At the time, pushing door to open by force will trigger the anti-force alarm. The default guard password is 2 ( digits) and alterable. HEART ENTERPRISE CO., LTD. 2

44 Guard function enable Default Display PRESS # PRESS 2 Or time out in 5 DC POWER ON.ENROLL 2.PASSWD.TIMER.SYSTEM.ALARM 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE.READER2. GUARD.TONE.PARK CURRENT: DISABLE CURRENT: ENABLE Default master code End of operation.7... Beeper sound of keys selection (Enable / Disable) A beeper sound comes out when a key being pressed (factory default enable), use the following procedure to disable this function when require: Beeper sound enable Default Display DC POWER ON PRESS #.ENROLL 2.PASSWD Default master.alarm 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE.READER2. GUARD.TONE.PARK PRESS CURRENT: DISABLE CURRENT: ENABLE Or time out in 5 End of operation.7... Car park functions enable Car park function is enabling K relay for exit contact using. So strong recommend any of users please DO NOT operate this function. HEART ENTERPRISE CO., LTD.

45 Beeper sound enable.7.5 Factory Default List Default Display DC POWER ON PRESS # PRESS Or time out in 5.ENROLL 2.PASSWD.TIMER.SYSTEM.ALARM 2.MODE.P_ZONE 2. E_ZONE.C_FREE.MORE.A_ZONE 2. ANTI_P.DURESS.MORE.READER2. GUARD.TONE.PARK CURRENT: DISABLE CURRENT: ENABLE Default master code End of operation Description Factory Default Access mode Mode 2 (Card data or password) Effective bits 2 Bits (HEART format) Master code Anti-duress function Disable Patrol function Disable Guard function Disable Tamper alarm Disable Force entry alarm Disable Door left open alarm (AJAR) Disable Alarm relay activated of door left open Disable Incorrect password key-in five times Disable Auto delete card of incorrect password Disable key-in five times Personal password function Disable Beeper key tone Enable Door relay active when door left open 20 more then the preset time Anti-duress relay active time 0 Alarm relay active time 0 Strike relay active time 0 Patrol relay active time HEART ENTERPRISE CO., LTD.

46 Chapter IV Error Message. ERROR / ALARM MESSAGE With self-diagnosis function, HA020 provides some error message for your further Information. Please consult technical people when require: E0 INVAL ID LOT NO The effective bit length of proximity card is 0 bits, the sample to take by HA020 are as follow:. Lower 2 bits only (Factory default) 2. Whole 0 bits The error message E0 indicates that the higher sampling data (6 bits) was deleted. E02 INVAL ID PASSWORD For the ond (card data + password) or third (card data or password) access mode selected, you are requested to input the password when enter the door. The error message E02 indicates that the incorrect password being used. E0 INVAL ID CARD All proximity cards should be registered before being used to enter the door. The error message E0 indicates that the card has not recorded. HEART ENTERPRISE CO., LTD. 5

E5 Series. Installation and Setup Guide

E5 Series. Installation and Setup Guide 801 Avenida Acaso, Camarillo, Ca. 90312 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com E5 Series Installation and Setup Guide P:\Installation Instructions\Access

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description. SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

PR602LCD v1.0 Installer Manual Rev. A

PR602LCD v1.0 Installer Manual Rev. A PR602LCD v1.0 Installer Manual Rev. A Introduction This document contents minimum information required for electrical connections and installation of the PR602LCD access controller in Roger Access Control

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

EL-ST100 KEYPAD CONTROLLER

EL-ST100 KEYPAD CONTROLLER WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6

More information

Stand-alone Proximity Access Control

Stand-alone Proximity Access Control Stand-alone Proximity Access Control User Manual INTRODUCTION VIDI-AC-1C is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. It uses

More information

RBR-SB-KTZ001 LAR 2. User Manual

RBR-SB-KTZ001 LAR 2. User Manual RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C

More information

-DTZ001- Stand-Alone Proximity Access Control. User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual -DTZ001- Stand-Alone Proximity Access Control User Manual INTRODUCTION DTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users,

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

ACTsmart2 Product Range Operating and Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING

More information

UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up

UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R int-r_en 09/11 The INT-R expander interfaces with the INTEGRA and CA-64 alarm control panels, replacing the previously offered CA-64 SR and CA-64 DR expanders.

More information

VIDI-AC-2CS Access Controller/ Reader

VIDI-AC-2CS Access Controller/ Reader VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM ACCESS CONTROL SYSTEM System versions Standalone controllers series based on integrated models KZ-400, 500, 600, 700, KZC-300,800, 900 KaDe Lite system based on integrated controllers KZ-1000 KaDe Premium

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

User Manual. Split access control with intelligent secured power supply.

User Manual. Split access control with intelligent secured power supply. User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.

More information

Installation guide for PR302 v2.0 Rev. E

Installation guide for PR302 v2.0 Rev. E Installation guide for PR302 v2.0 Rev. E 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document is subject to the Terms of Use in their current version published at the www.roger.pl website of

More information

W3-M. Metal waterproof standalone access control/reader. User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

_ Access control SISTEMAS DE SEGURIDAD

_ Access control SISTEMAS DE SEGURIDAD _ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

GV-Card Reader. User s Manual

GV-Card Reader. User s Manual GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights

More information

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its

More information

9212i INSTALLATION. Stand-Alone Keypad. Instructions

9212i INSTALLATION. Stand-Alone Keypad. Instructions INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

RFID PRODUCT AND SYSTEM

RFID PRODUCT AND SYSTEM EL500(T)-X-XX Access control system, EM125kHz technology EL500-X-0C EL500-X-1C EL500-X-0D Economic access control system, EM125kHz technology Economic access control system, EM125kHz technology, with keypad

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01 Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details EN FULL DETAILS SKB Vandal Resistant keypad - Full Details WARNINGS Carry out the installation by carefully following the instructions provided by the manufacturer in accordance with the current standards.

More information

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.

More information

U-FLASH Setup Guide U-FLASH.

U-FLASH Setup Guide U-FLASH. U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

AXS-100. User's Guide. Two-Door Proximity Access Control System (V2.06) DE6280U 1

AXS-100. User's Guide. Two-Door Proximity Access Control System (V2.06) DE6280U 1 AXS-100 Two-Door Proximity Access Control System (V2.06) User's Guide Table of Contents 1. INTRODUCTION... 3 2. USER INTERFACE... 3 2.1. Keypad...3 2.2. Idle Screen...3 2.3. Login Screen...4 2.4. Operating

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0 Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7

More information

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader Features: Rugged construction heavy-duty stainless steel faceplate with coated steel housing Built-in proximity card reader 12~24

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

WRI400 WIRELESS READER INTERFACE

WRI400 WIRELESS READER INTERFACE WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 March 12 Technical Services Engineering Support 1 Training Overview WRI400 Description Information Installation

More information

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

CM-500 SK 500 USER CODES KEYPAD

CM-500 SK 500 USER CODES KEYPAD CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage

More information

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint

More information

Specifications: Features:

Specifications: Features: ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm

More information

Modules Programming Guide. paradox.com

Modules Programming Guide. paradox.com Keypad Modules Annunciator Module Motion Detector Modules Zone Expansion Modules Access Control Module Voice Assisted Modules Accessory Modules Integration Module Internet Module Modules Programming Guide

More information

FTK5 PROXIMITY KEYPAD

FTK5 PROXIMITY KEYPAD FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference 1 There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records

More information

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01 ROSSLARE MODE 1 2 DOOR 3 4 5 6 7 8 9 0 # AC-115 Hardware Installation and User s Guide 10/01 ROSSLARE Hardware Installation and User s Guide for the AC-115 Access Control System MODE 1 2 DOOR 3 4 5 6 7

More information

7612 Programming Instructions

7612 Programming Instructions 7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards 7612 is a vandal resistant proximity card and keypad access control

More information

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Function Menu 1.Add/Delete 2.User Setting 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Delete FP 1. Add - Card ID 2. Add - RF-learn 3. Suspend - Addr 4.

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

IBA-7612 Programming Instructions

IBA-7612 Programming Instructions IBA-7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards IBA-7612 is a vandal resistant proximity card and keypad access

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

Pegasus Equipments Export Limited. Local Contact:

Pegasus Equipments Export Limited. Local Contact: Pegasus Equipments Export Limited Add: #31G, Haiyige, Scienway Palace Science & Technology Industrial Park Shenzhen, China. Tel: +86 755 2658 3464 +86 755 2658 3596 Fax: +86 755 8611 0167 web: www.pegasusexport.com

More information

GV-RK1352 and GV-R1352 Card Reader

GV-RK1352 and GV-R1352 Card Reader GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured

More information

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL

More information

Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption

Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption SOYAL ACCESS CTROL SYSTEM AR-E V0 Contents Product User Guide Panel Mounting Base WG Key-panel Reader Option AR-0B-X Fit mm DIN Rail or Mount directly AR-K AR-K AR-K Option For Stand-alone Command Setting

More information

MCX402DR-BRD I/O expander. Operating Manual

MCX402DR-BRD I/O expander. Operating Manual Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: 1.0.2.255 Document version: Rev. B Design and application The MCX402DR-BRD is I/O expander

More information

Operation manual For NG BIOSINGLE Version 1.1

Operation manual For NG BIOSINGLE Version 1.1 Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,

More information

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

RFID/Digital Access Control Keypad

RFID/Digital Access Control Keypad R Luminous/ RFID/Digital Access Control Keypad Model:YK-368L-R Germany EMC tested FEATURES AND FUNCTIONS Simple Programming, Easy Operation 3-Operation Mode: ID Card Operation, User Code Operation, ID

More information

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX ISC910-1-0-GB-XX ISC911-5-0-GB-XX ISC920-0-0-GB-XX ISC921-5-0-GB-XX The ImproX IXP20 is a fully featured, stand-alone Access Control System supporting up to 1 000 Tagholders and 5 000 transactions. Designed

More information

Click Save to return to the main Setup screen.

Click Save to return to the main Setup screen. ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

CV-945 Stand-Alone Biometric Reader. Installation Instructions

CV-945 Stand-Alone Biometric Reader. Installation Instructions CV-945 Stand-Alone Biometric Reader Installation Instructions Contents 1.0 Introduction... 03 2.0 Mounting... 03 3.0 Specifications... 04 4.0 Application Diagram... 04 5.0 Wiring... 05 6.0 Recommended

More information

HSY-S209 EM Metal waterproof access control system User Manual

HSY-S209 EM Metal waterproof access control system User Manual HSY-S209 EM Metal waterproof access control system User Manual Reading carefully before Install and use this manual 1. Product Profile The product is Contact-less inductive card Metal Password Access Controller,

More information

Two-door Access Controller

Two-door Access Controller Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following

More information

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web: ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

PRxx1 series controllers Functional Description and Programming Guide

PRxx1 series controllers Functional Description and Programming Guide Roger Access Control System PRxx1 series controllers Functional Description and Programming Guide Document version: Rev.E This document refers to the following products: PR311SE, PR311SE-BK, PR611, PR621,

More information

Stand-Alone Data Chip System

Stand-Alone Data Chip System Stand-Alone Data Chip System OVERVIEW This Data Chip System supports up to 17 users and each user can be added or deleted in a matter of seconds. This System can be used in a variety of Security and Access

More information

1. Product Specification

1. Product Specification 1. Product Specification Item Specification Voltage 12VDC +10%, Current 1.2A Lock Relay 12VDC/2A Environmental Temperature working:0 ~45 ; storage:-10 ~55 Relative humidity working:40%~90%rh; Card Capacity

More information

ATS1190 Smart Card Reader Programming Manual

ATS1190 Smart Card Reader Programming Manual ATS1190 Smart Card Reader Programming Manual Version 2.0 Aritech and Tecom are Interlogix Companies 2001 Interlogix B.V.. All rights reserved. Interlogix B.V. grant the right to reprint this manual for

More information