Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption

Size: px
Start display at page:

Download "Option. AR-701B-X Fit 35mm DIN Rail or Mount directly AR-721K AR-725K AR-331K 1456 RAM. WG 26 / WG 34 Power Supply. YES Power Consumption"

Transcription

1 SOYAL ACCESS CTROL SYSTEM AR-E V0 Contents Product User Guide Panel Mounting Base WG Key-panel Reader Option AR-0B-X Fit mm DIN Rail or Mount directly AR-K AR-K AR-K Option For Stand-alone Command Setting Specification CPU bit CPU Temperature -0 ~ +0 Event log RAM k Bits Digital Input Door Open Button/ Door Sensor/ Housing open detection/ Prepared for DI Aux. WG Port WG / WG Power Supply 0 ~ Relpy Output Door Relay/ Alarm Relay/ Prepared for Relay output Anti-pass-back YES Power Consumption < W Transistor Output Prepared for DO Lift Control NO Interface RS- Door Relay Time Toggle, 0.~00Ses Time Zone (stand-alone /networking) Baud Rate 900 bps, N,, Alarm Relay Time Toggle, 0.~00Ses Real Time Clock YES External WG Readers WG (Controller power supply) User Capacity,000 DIP_SW (Node ID: ~) Connector Table P P 0 9 Dip-switch 0 9 Node ID is setting by DIP_Switch, Node ID: 0~ Value DIP SW Node 0 Node 0 Node 0 Node Node ~ OUT DO OUT ALM P P P Connector: P RS- / Power LA+ LB- DC RS-(A+) RS-(B-) DC Power 0V DC Power Connector: P WG Port OUT TAM () SEN () PB () WG 9 0 / Beeper Output LED Green Output LED Red Output Tamper Switch Input Door Status Input Exit Button Input Wiegand DAT: Input Wiegand DAT:0 Input DC Power Output Connector: DI DI P Digital Input Pin DI Fire-alarm Input Connector: P Relay / Alarm Output DO ALM / / Connector: P WG Port OUT PB () SEN () TAM () WG 9 0 / LED Red Output LED Green Output Beeper Output Exit Button Input Door Status Input Tamper Switch Input Wiegand DAT:0 Input Wiegand DAT: Input DC Power Output Connector: DO DO Transistor Output DO DO Wiring Diagram P AR-H Connect to PC P Connect to Alarm or Other Converter B- A+ DC DC AR-E P 0V B- A+ ALM DO AR-E P Alarm

2 Door WG Controller V0 P AR-H Connect to Electric Strike P Connect to Magnet Lock or Electric Bolt Tamper Switch Electric Strike DC Tamper Switch Magnet Lock or Electric Bolt DC Reader A WG WG Door Sensor EXIT WG 0 WG Reader B 0 9 Door Sensor EXIT P AR-H About Digital Input WG PB SEN TAM LR LG AR-E P OUT Push Button WG TAM SEN PB AR-E P About Transistor Output OUT Push Button If the Power line more than 00 m between the Controller and Reader, it is recommended NOT to use the "Wiegand Power". See connection mode within the dashed box, Controller and Reader must to do "common--point". Relay Output Module CTL DI DI AR-E P Relay Output Module DC CTL DO AR-E P All commands below are only able to set up by connected with WG key-panel reader. Adding and Deleting Tag Add Single Tag or Random tags Input (or Master ) 9 UUUUU 0000 Present the tag(s) with reader (single tag or random numbered cards one by one) Done [e.g.] readom cards with user addresses No. 00 and No. 0: Access programming mode Present the tags one by one Done Add the Sequential tags Input (or Master ) 9 UUUUU QQQQQ Present the tags (Present the tag with the lowest number first.) OK [e.g.] User Address NO.0 to NO.0 have 0 pcs of sequential tags:(~): Access programming mode Close Tag into RF Area(only use the tag NO.) OK Delete a Single Tag Input (or Master ) 0 SSSSS 9 EEEEE [e.g.] Delete User Address: 000 Access programming mode Delete a batch of Tags Input (or Master ) 0 SSSSS 9 EEEEE [e.g.] Delete User Address: 000~00 Access programming mode Operation process Delete All Tags Input (or Master ) 9 9 Tag Information CARD CODE SITE CODE A. Enter/ Exit Program Mode Enter the program mode Input or PPPPPP [e.g.] The Default Value=, if already changed the Master =, input program mode accessed Exit the program mode Input Master modification Access programming mode 09 PPPPPPRRRRRR [Input the -digit new master code twice.] [e.g.] Set the Master code to be, input 09 DO CARD CODE SITE CODE

3 SOYAL ACCESS CTROL SYSTEM AR-E V0 B. Chang the Node ID of Reader Access programming mode 00 NNN [Node ID: 00~] C.Set up M/M Access programming mode 0 N [N=/] D. Set up the password Card or PIN: Access programming mode UUUUU PPPP [e.g. User address: 0000 and pass code:, input 0000 ] Card and PIN: Access programming mode UUUUU PPPP [e.g. User address: 0000 and pass code:, input 0000 ] E. Anti-pass-back(Reader A and Reader B must to be setting) Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need access and exit monitor. Controller enable Access programming mode 0 DDD [= Anti-pass-back(0=Disable; =Enable)/ 0=Access/Exit(0=Exit; =Access).] [e.g.] Enable Anti-pass-back, and set to Exit door= ( x ) + (0 x 0) = Access programming mode 0 () Card enable Access programming mode SSSSS EEEEE N [SSSSS= User address start; EEEEE= User address end; N=0(control)/ (Not control)/ (reset)] [e.g.] User address from 00 to 00 enable the anti-pass-back function: [e.g.] No. enable the anti-pass-back, and induction into the door has not been induced to leave. When he re-induction into the door will become invalid, then he needs to set the reset. Access programming mode Reset F. Auto Open Time Zone Door will keep open after the first flashing card.there are time zones supported. Enable/Disable auto open zone Access programming mode 0 00 [00= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone] Enable/Disable auto open door without presenting card Access programming mode 00 [00= enable Auto-Open Time Zone; 000= disable Auto-Open Time Zone] Set up open time Access programming mode 0 N HHMMhhmm H N: sets of auto-open zone (N=0=st set; N==nd set) HHMMhhmm=Staring time to ending time (e.g. 0000=0:0 to :00) H= days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun) + Holiday (F= 0: disable; : enable); Holidays establish by the software. [e.g.] To set the second time zone as 9:0 AM to :0 PM, Monday, Wednesday and Friday: Done G. Setting Up the Arming Application: Alarm conditions:. Door open too long: Door is open longer than door relay time plus door close time.. Arming is enabled. Force open (Opened without a valid user card): Access by force or illegal procedure..alarm system connected. Door position abnormal: When power is and then on, reader on arming bffore power. Enable/Disable Arming status (Factory default armingcode is: ) : Standby Mode After door open The normal procedure to open door Input digit arming code Door is not open Input digit arming code Present valid card Enter Program Mode Enable: Access programming mode [The normal procedure to open door] can refer to [Access Mode]. Function Default Value 0 DDD Disable: Access programming mode Attendance 0: Yes : No 0 00 Networking Auto Re-lock : Enable 00 Auto Open : Enable 00 Door open button input 0: Disable : Enable 0 Master Reader of Network 0: Slave : Mater 0 Networking Access/Exit 0: Exit : Access 0 Networking Anti-pass-back : Enable Networking DDD Auto-open door without cards at auto open zone : Enable 0 00 Stop Alarm by door close or by push button 0: None : Yes 0

4 Door WG Controller V0 DDD Can be password-free in the Card or PIN mode Reset the Anti-pass-back by the software Arming for force open : Enable : Enable : Enable 0 0 Selection= 0(none value)/ ( x each value) [e.g.] DDD value of Enable Auto Open + Exit by Push Button + Anti-pass-back =00+0+=; As a result of that, the command will be 0. Mode/ Mode Mode :.Card only;.card and PIN (-digit PIN) + ;.Card or User address (-digit) + Individual PIN (-digit individual PIN) + Mode :.Card only;.card and PIN (-digit individual PIN) + Command List General instructions Function Entering programming mode Exiting programming mode Control mode setting Master card setting Auto-open time zone setting Command PPPPPP 0 N 0 SSSSS EEEEE 0 N HHMMhhmm H ;.Card or PIN (-digit individual PIN) PPPPPP=Master, default value= N=Mode =Mode;=Mode SSSSS-EEEEE= ; SSSSS=Starting user address; EEEEE=Ending user address N= 0(st time zone) / (nd time zone) HHMM= Starting time; hhmm= ending time Notes (i.e.: 0000=0:0 to :00) H= days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun) + Holiday (F= 0: disable; : enable); Holidays establish by the software. Master code setting 09 PPPPPPRRRRRR PPPPPP=New master code RRRRRR=Repeat the new master code Suspend / Delete tag Active the suspended cards Set the cards as Card mode OR PIN mode 0 SSSSS EEEEE 0 SSSSS 9 EEEEE SSSSS EEEEE UUUUU PPPP =Suspend 9 =Delete; SSSSS=Starting user address, EEEEE=Ending user address SSSSS=Starting card number, EEEEE=Ending card number Access mode: Card or PIN; UUUUU=user address; by user address Set the cards as Card AND PIN mode UUUUU PPPP PPPP=-digit pass code 000~9999 Access mode: Card and PIN; UUUUU=user address; by user address Duress code setting PPPP PPPP=-digit pass code 000~9999 PPPP=-digit pass code (default value=) P.S. Duress code will be unavailable and become a public PIN at access mode Card or PIN of M Card number modification Arming pass code setting UUUUU SSSSSCCCCC PPPP UUUUU= User address; SSSSS=-digit site code; CCCCC=-digit card code PPPP=-digit pass code ( default value=; disable Arming PWD=0000) P.S. Arming PWD code will be unavailable and become a public PIN at access mode Card PIN and of M Door open waiting time Set the card by induction(m/m) TTT 9 UUUUU QQQQQ TTT=Door open waiting time: 00~00=~00 sec.; default value: sec. UUUUU=User address(range: 00000~0999); QQQQQ=Card quantity(0000=continuously inducting) Controller parameter setting Controller time clock setting Anti-pass-back (Enable user) DDD YYMMDDHHmmss SSSSS EEEEE N YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec. SSSSS=Starting user address; EEEEE=Ending user address; N=0/Enable; N=/Disable; N=/Initial Controller control setting Delete all tags DDD 9 9 Individual instruction set Function Keyboard Lock/ Unlock Command Press and hold for seconds to lock the keyboard, again to unlock. Notes Exiting programming mode and enabling arming status Node ID setting (for Reader) Door relay time setting 00 NNN 0 TTT NNN=Node ID, range: 00~ TTT=Door relay time 000= Output constantly 00~00=~00 sec. 0~09=0.~0.9 sec. Alarm relay time setting Controller additional setting 0 TTT 0 DDD TTT=Alarm relay time 00~00=~00 sec.

5 Budapest, Fogarasi út. Tel.: *0-90, 0-, 0-99, 0-, - Fax: 0-90 Mobil: 0 -, Budapest, Mester utca. Tel.: *-, -9, -0, -0, -0 Fax: - Mobil: , info@delton.hu Web:

SOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M

SOYAL AR-321H/AR-721H/ AR-725H/AR-757H ACCESS CONTROL SYSTEM. Contents AR-321H [Metal Case] AR-721H. AR-725H [Illuminated Touch-panel] AR-725H-M SOYAL AR-H/AR-H/ AR-H/ ACCESS CONTROL SYSTEM Contents AR-H [Metal Case] Product Water proof Strip d x AR-H Product f x AR-H [Illuminated Touch-panel] AR-H-M Products c x e x A. B. C. D. AR-H Products f

More information

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud

More information

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H)

AR-321 (H) / AR-331 (H)/ AR-721(H) / AR-725 (H) / AR-757 (H) AR- (H) / AR- (H)/ AR-(H) / AR- (H) / AR- (H) SOYAL ACCESS CONTROL SYSTEM V0 Contents AR- (H):Touch-panel Metal Housing Product User Guide Terminal Cables Tools Water proof Strip d x P P P P AR- (H):Touch-panel

More information

SOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter

SOYAL AR-321H/AR-331H/ AR-721H/AR-725H/AR-757H ACCESS CONTROL SYSTEM V Contents AR-321H [Touch-panel Metal Housing] 1 Product 2 User Guide 3 Ter SOYAL AR-H/AR-H/ AR-H/AR-H/AR-H ACCESS CONTROL SYSTEM Contents AR-H [Touch-panel Metal Housing] Product User Guide Terminal Cables Water proof Strip d x AR-H [Touch-panel Metal Housing]/ AR-H-S [Metal

More information

SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X

SOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 Contents AR-E-M Products User Guide Terminal Cables Tools P P P P c x d x A. B. C. D. P P P P AR-E Products User Guide Terminal Cables Tools P P P P

More information

ECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C.

ECL-ACC980IP-V2/VP. Contents ECL-ACC980IP-V2. Installation ECL-ACC980IP-V2 ECL-ACC980IP-VP. Parts Description ECL-ACC980IP-VP A. B. C. EC-ACC90IP-/P Contents EC-ACC90IP- Products User Guide Terminal Cables Tools P P P a x A. E. F. P P P P EC-ACC90IP-P Products User Guide Terminal Cables Tools P P P b x A. B. C. D. P P P P c x Parts Description

More information

SOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X)

SOYAL AR-725 (E-V2) V Contents AR-725 (E-V2-M) Installation AR-725 (E-V2-M) AR-725 (E-V2) AR-725 (X) Parts Description AR-725 (E-V2) AR-725 (X) SOYAL ACCESS CONTROL SYSTEM AR- (E-V) V0 Contents AR- (E-V-M) Products User Guide Terminal Cables Tools P P P c x d x A. B. C. D. P P P P AR- (E-V) Products User Guide Terminal Cables Tools P P P e x A.

More information

AR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function.

AR-881(EF-MT) P4 P5 P6 P7. P7 only provide to the controller that have doorbell function. SOYAL ACCESS CONTROL SYSTEM AR- (EF) V00 Contents Product User Guide Terminal Cables Tools Optional P P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 WG keyboard AR-(EF-DO) Installation

More information

SOYAL AR-331(EF) Contents. Front Panel & Indicator. Installation. Connector Table CN6 CN2 V Option. 4 Accessories. 2 Terminal Cables 3 Tools

SOYAL AR-331(EF) Contents. Front Panel & Indicator. Installation. Connector Table CN6 CN2 V Option. 4 Accessories. 2 Terminal Cables 3 Tools SOYAL ACCESS CONTROL SYSTEM AR- (E/EF) V0 Contents Product Terminal Cables Tools Accessories Option P P Flat Head Cap Philips Tapping Screw: x0 Security Torx: Mx0 AR-(E) AR-(EF) P P P Security Torx Wrenches

More information

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Contents AR- (EF-V):Fingerprint Products User Guide Terminal Cables Tools Optional P P P AR- (EV-V):Vein P P P AR-RB Products User Guide Terminal Cables

More information

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input SOYAL ACCESS CONTROL SYSTEM AR- (E) / (EF) V Contents AR- (EF):Fingerprint Products User Guide Terminal Cables Tools DO AR- (E) Or MT P P P P P P P P P P P P Water proof Strip Optional Products User Guide

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

AR-727H. Technical Manual. 26 August Version 1.00

AR-727H. Technical Manual. 26 August Version 1.00 AR-727H Technical Manual 26 August 2008 Version 1.00 Southern Office: Raytel House Brook Road Rayleigh Essex, SS6 7XH Tel: (01268) 749310 Fax: (01268) 749315 Northern Office: Unit 3 Block 5 Oakbank Industrial

More information

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.

Function Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Function Menu 1.Add/Delete 2.User Setting 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Delete FP 1. Add - Card ID 2. Add - RF-learn 3. Suspend - Addr 4.

More information

RFID PRODUCT AND SYSTEM

RFID PRODUCT AND SYSTEM EL500(T)-X-XX Access control system, EM125kHz technology EL500-X-0C EL500-X-1C EL500-X-0D Economic access control system, EM125kHz technology Economic access control system, EM125kHz technology, with keypad

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

Set-up of ZK RFID Pin Pad

Set-up of ZK RFID Pin Pad Set-up of ZK RFID Pin Pad Version 0. 1 Prepared by: Shaun Laas Softcon Software Control Services (Pty) Ltd. 7 March 2017 Revision History Name Date Reason For Changes Version SL SL 26-Jan- 2016 26-Jan-

More information

Pegasus Equipments Export Limited. Local Contact:

Pegasus Equipments Export Limited. Local Contact: Pegasus Equipments Export Limited Add: #31G, Haiyige, Scienway Palace Science & Technology Industrial Park Shenzhen, China. Tel: +86 755 2658 3464 +86 755 2658 3596 Fax: +86 755 8611 0167 web: www.pegasusexport.com

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

TECHNICAL OPERATION GUIDE

TECHNICAL OPERATION GUIDE TECHNICAL OPERATION GUIDE CASTLE K-SERIES SYSTEM CASS TECHNOLOGY SDN BHD(338857-X) 1 Disclaimer 2004 Cass Technology Sdn Bhd, All Right Reserved. Information of this documentation is subject to change/modification

More information

ACTsmart2 Product Range Operating and Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING

More information

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers

AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers Installation and Programming Guide AR-716E-RAY EAR-727HB-RAY AR-727HB-RAY 10th August 2011 Version 1.00 Southern Office: Raytel House Brook

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

KP200 INTELLIGENT KEYPAD

KP200 INTELLIGENT KEYPAD KP200 INTELLIGENT KEYPAD V3 NEATROL SYSTEMS 25B Harlond Avenue, Malaga W.A. 6090 Phone : (08) 9248 1646 Fax : (08) 9248 2003 Table of contents 1.1 Summary of Master Functions. 1.2 Explanation of master

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product.

This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product. F18 User Manual Version: 1.0 Date: Dec. 2011 Introduction: This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product. About this manual 1. Not all the devices

More information

NetworX Series NX-1710E Single Door Control. Installation and Startup Manual

NetworX Series NX-1710E Single Door Control. Installation and Startup Manual NetworX Series NX-1710E Single Door Control Installation and Startup Manual 2005 GE Security All rights reserved. NetworX is a trademark of the GE companies. Printed in the USA. These instructions do not

More information

TECHNICAL OPERATION GUIDE

TECHNICAL OPERATION GUIDE TECHNICAL OPERATION GUIDE CASTLE COMMANDO SERIES CONTROLLER Disclaimer 2004 Cass Technology Sdn Bhd, All Right Reserved. Information of this documentation is subject to change/modification without any

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

BioPointe Reader Installation Guide

BioPointe Reader Installation Guide BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

FTK5 PROXIMITY KEYPAD

FTK5 PROXIMITY KEYPAD FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference 1 There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records

More information

Installation and User Manual

Installation and User Manual S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

Security at Fingertips

Security at Fingertips Security at Fingertips www.esslsecurity.com Contents 1. Operating Instruction... - 1-1.1 Abbreviated Operating Procedures... - 1-1.2 Introduction to Fingerprint Recognition technology... - 2-1.3 About

More information

U-FLASH Setup Guide U-FLASH.

U-FLASH Setup Guide U-FLASH. U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk

More information

Visit us on the World-Wide Web at Programming Guide. Controller Boards

Visit us on the World-Wide Web at   Programming Guide. Controller Boards Visit us on the World-Wide Web at www.chamberlain.com PRO Systems Programming Guide Controller Boards -106 & -107 PROKey PROCard TABLE OF CONTENTS INTRODUCTION About the PRO System................................3

More information

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out

More information

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web: ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers

More information

Bewator Granta Controller Installation Handbook

Bewator Granta Controller Installation Handbook Bewator Granta 4101-2 Controller Installation Handbook Copyright 2004 Bewator AB, Solna. This handbook is based on the best information available to Bewator Cotag at the time of publication. Although every

More information

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint

More information

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX ISC910-1-0-GB-XX ISC911-5-0-GB-XX ISC920-0-0-GB-XX ISC921-5-0-GB-XX The ImproX IXP20 is a fully featured, stand-alone Access Control System supporting up to 1 000 Tagholders and 5 000 transactions. Designed

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

AXS-100. User's Guide. Two-Door Proximity Access Control System (V2.06) DE6280U 1

AXS-100. User's Guide. Two-Door Proximity Access Control System (V2.06) DE6280U 1 AXS-100 Two-Door Proximity Access Control System (V2.06) User's Guide Table of Contents 1. INTRODUCTION... 3 2. USER INTERFACE... 3 2.1. Keypad...3 2.2. Idle Screen...3 2.3. Login Screen...4 2.4. Operating

More information

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

2.4 inch Color Screen Series User Manual

2.4 inch Color Screen Series User Manual 2.4 inch Color Screen Series User Manual Version: 1.3 Date: June 15, 2013 Introduction: This document mainly introduces interface and operation of 2.4 Inches color products. ALARM INTERNATIONAL SYSTEMS

More information

2 Zone Time Clock. User Guide UFHTIME2B

2 Zone Time Clock. User Guide UFHTIME2B 2 Zone Time Clock User Guide UFHTIME2B Overview The 2 Zone Time Clock is designed to work with the Dial Thermostat (UFHDIALB) to provide time control per manifold. Time clock also has 1 other zone which

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x

More information

Startup Guide. NetAXS-123. Version 5.2

Startup Guide. NetAXS-123. Version 5.2 NetAXS-123 Startup Guide Version 5.2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)

More information

User Manual. Split access control with intelligent secured power supply.

User Manual. Split access control with intelligent secured power supply. User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.

More information

Installation Instructions (KF-2000)

Installation Instructions (KF-2000) VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Key Switch. Document version: 1.5 (Updated 02 May 2017) Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling

More information

PRO3200 Professional Modular Access Control Hardware

PRO3200 Professional Modular Access Control Hardware PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL 01/2004 Centaur is a registered trademark of Position Technology INC. Pro-Report, Tracker, FrontGuard and FrontView are trademarks of Position Technology Inc.

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

Created by: Alarm System Store   Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8 Quick Start Guide for Interlogix NetworX NX4, NX6 & NX8 Programming Code = 9713 Master User Code=1234 Program Mode= *8 + 9713 To exit programming hit the Exit key until you reach the home screen If this

More information

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Wiring Guide EP.NMINI. Version 1.02 Last Updated: Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C

More information

USER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1

USER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1 USER MANUAL BioPro SA50 Fingerprint & Palm Terminal Version: 1.0 Date: August. 2017 2.4 Inch TFT Terminal User Manual 1 About This Manual This manual introduces the operation of user interfaces and menu

More information

ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA3035 VERSION: 2.9x

ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA3035 VERSION: 2.9x ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA05 VERSION: 2.9x HEART ENTERPRISE CO. LTD. HEART ENTERPRISE CO., LTD. 0 Chapter I Introduction. Introduction 5.2 Features 5. Specification 6.

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

_ Access control SISTEMAS DE SEGURIDAD

_ Access control SISTEMAS DE SEGURIDAD _ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams

More information

Two-door Access Controller

Two-door Access Controller Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.

More information

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules This guide supplements the Synergis Master Controller Configuration Guide and explains how to configure Axis interface modules

More information

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL

More information

Installation & User Manual

Installation & User Manual Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com

More information

DINB100-SA-KIT Standalone Biometric Kit

DINB100-SA-KIT Standalone Biometric Kit DINB100-SA DINRTT DINB100-SA-KIT Standalone Biometric Kit User Manual v.b3 Contents 1.0 INTRODUCTION... 3 2.0 MOUNTING AND DISMOUNTING... 3 3.0 SPECIFICATIONS... 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING...

More information

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description. SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming

More information

K44 Code lock. Technical manual

K44 Code lock. Technical manual K44 Code lock GB Technical manual Copyright 2002 Bewator AB, Solna, Sweden. Material from the K44 Technical manual may only be copied with the consent in writing of Bewator. Bewator reserves the right

More information

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram BHD-8000 Access Control Keypad and Card Reader Wiring Diagram Frontal View Main Technical Specifications Item Operating Voltage Unlock Relay Operating Temperature Value 12VDC+12%/1.2A 12VDC/2A Normal Operation:

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL

More information

Webpass IP Reader. WEB Configuration Manual

Webpass IP Reader. WEB Configuration Manual Webpass IP Reader WEB Configuration Manual WEBPASS version : v0.09 Aug-24 th -2009 (HW.1.0) WEBPASS Web version : v1.4 Build date : Aug-18 th -2009 Revision History 1. Newly added Event Type : Alarm and

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD Entryphone PinNet 4 Product manual October 2010 R4.9 www.entryphone.co.uk 23 Granville Road, London SW18 5SD This document covers the installation and use of the Entryphone on-line PinNet door control

More information

First Access Express OPERATOR GUIDE

First Access Express OPERATOR GUIDE First Access Express OPERATOR GUIDE October 2016 Cutting edge simplicity Table of Contents Introduction... 4 PC Requirements... 5 Step 1. Software Installation... 5 Complete Installation Server and Client...

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

IQ PROX. Programming Guide. Series. For use with IQ KP* only

IQ PROX. Programming Guide. Series. For use with IQ KP* only IQ PROX Series Programming Guide For use with IQ KP* only Congratulations, you have just purchased the IQ KP*series lockset by Marks USA, the most advanced stand-alone door lock and access control system

More information

A-1300 Biometric Access Control System USER'S MANUAL

A-1300 Biometric Access Control System USER'S MANUAL A-1300 Biometric Access Control System USER'S MANUAL Table of Contents 1. General Information... 1 1.0 Notification... 2 1.1 System Overview... 2 1.2 Main Features... 2 1.3 Equipment... 3 2. Basic Concepts...

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

User s Manual V

User s Manual V User s Manual V2. 28.1.21 Table of Contents 1 About BF-88X/87X...3 2 Features...3 2.1 Characteristics...3 2.2 Support functions...3 2.2.1 User management...3 2.2.2 System management...4 2.2.3 Door mode...4

More information

SmartLock Pro INSTALLATION MANUAL

SmartLock Pro INSTALLATION MANUAL SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights

More information