MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER
|
|
- Randolf Townsend
- 5 years ago
- Views:
Transcription
1 MODEL: MAT Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTI SURE PROTETOR FOR THREE-PHASE POWER SUPPLY Functions & Features onnected in parallel between the power and earth lines regardless of load current Applicable to single phase /-wire and threephase /4- wire system High discharge current capacity 0 ka or 40 ka (8/0 μs) Degraded head element is automatically separated from the power lines by the incorporated thermal breaker, and the LED lamp (turns off) and the relay contact alerts the failure status. omplies with IE 664- lass II Typical Applications Low-voltage distribution board ombination with installation for large load current 50 (.97) 60 (.6) 98 (.86) mm (inch) MODEL: MAT 40[]M[] ORDERI IFORMATIO ode number: MAT-40[]M[] Specify a code from below for each [] through []. (e.g. MAT-40MY) ORATIOAL VOLTAE 40: 40 V A [] ALARM OUTPUT A: With Y: Without EERAL SIFIATIOS onstruction: Standalone; terminal access at the front Degree of protection: IP0 (If the solderless terminals are covered with insulation tubes.) Surge protection type: Voltage limiting type one-port SPD onnection Line: M5 screw terminal (torque:.5 m) : Tension clamp Applicable wire size Line: See the drawing below. : 0. to.5 mm (8 mm exposed) Screw terminal Line: ickel-plated steel : Tin-plated copper alloy Housing material: Flame-resistant resin (black) : SPDT relay contact trips when the thermal breaker operates. OUTPUT TERMIAL ormal: Open Failure or power off: lose OUTPUT TERMIAL ormal: lose Failure or power off: Open Rated load: 50 V A (resistive load) 4 V A (resistive load) Safety function: Thermal breaker incorporated Monitor LED: reen LED turns on during normal condition and turns off during failure condition, power off or the thermal breaker operating. Applicable Solderless Terminal Size diameter d B T F d : M5 use B.0 mm F 7.0 mm (F 8. mm for sharing terminals) T.8 mm [] POWER SYSTEM : Single-phase /-wire, Three-phase -wire 4: Single-phase /-wire, Three-phase /4-wire MAXIMUM DISHARE URRET M: 0kA (8/0 μsec.) ISTALLATIO Operating temperature: -5 to +55 ( to F) Operating humidity: 5 to 95 %RH (non-condensing) Mounting: DI Rail Weight: 00 g (0.66 lb) MAT SIFIATIOS ES-864 Rev.0 Page /5
2 MODEL: MAT RFORMAE Response time: nanoseconds ( 0 nanoseconds for to ) Insulation resistance: 00 MΩ with 500 V D (line to alarm output) Dielectric strength: 000 V minute (line to alarm output) MODEL MAT-40 MAX. OTIUOUS ORATI VOLTAE (Uc) Between lines: 40 V A to : 0 V A DISHARE VOLTAE (Vmin) Between lines: 400V to : 550V VOLTAE PROTETIO LEVEL (Up) 500 ORATIOAL VOLTAE RAE * (50 / 60Hz) -phase/-wire, -phase/-wire: 90 40V A -phase/-wire: 90 / 80 0 / 40V A -phase/4-wire: 70 40V A MODEL MAT-40 Line to Line MAX. LEAKAE ALARM OUTPUT WITH WITHOUT to ma * 6mA * Other sections ma ma to 0µA 0µA *. MAT is operational as an SPD despite the voltage less than the minimum. However, the functions of the monitor LED and the alarm output are not guaranteed. *. Approx. A *. Approx. A MODEL MAX. DISHARE URRET (Imax) OMIAL DISHARE URRET (In) MAT-40xMx 0kA (8/0µsec) 0kA (8/0µsec) STADARDS & APPROVALS EU conformity: Low Voltage Directive E 664- RoHS Directive E 5058 Surge protection: IE 664- lass II E 664- lass II MAT SIFIATIOS ES-864 Rev.0 Page /5
3 MODEL: MAT OETIO EXAMPLES ISTALLATIO EXAMPLES: Three-phase 4-wire connection ) * ) 4) * 5)a L L L * Residual urrent ircuit Breaker ) : Protective of the switchgear ) : ircuit breaker ) : Main earth terminal or busbar 4) : MAT 5) : Earth conductor 5)a and/or 5)b 6) : EB : Main's earth electrode ED : Switchgear's earth electrode 5)b 6) *4 EB ) ED *. The circuit breaker or the fuse as disconnectors must be installed. Molded-case circuit breaker (MB) or residual current circuit breaker with overcurrent protection (RD) can be used. The rated interrupting capacity of the circuit breaker must be greater than the highest amount of current that could be available in the circuit. Install MB (rated current 0 0A) that has element for each phase. Or RD with protection from nuisance tripping against transit voltages type or time-delay overcurrent protection type is recommended. Recommended sensitivity current rating: 0mA *. able length between the branch point and the earthing: 0.5 meters or less recommended *. The protected 's metal enclosure must be cross-wired to the earth terminal of the MAT. If the protected has no earth terminal, earth only the MAT. *4. In order to protect an electronic circuit such as measuring equipment or communication equipment, we recommend to use surge protectors which have serial impedance incorporated such as M-System's models MAX, MMA, MAH. MAT SIFIATIOS ES-864 Rev.0 Page /5
4 MODEL: MAT OETIO EXAMPLES BY POWER SYSTEMS Abnormal voltages appearing in case of a light load or a fault earth loop must be within the maximum continuous operational voltage when selecting the MAT models. POWER SYSTEM Single-phase/-wire Three phase/-wire (delta connection) () ircuit breaker () ircuit breaker OETIO * * EXAMPLE POWER SYSTEM Single-phase/-wire 0V A Single-phase/-wire 0V A Single-phase/-wire (three-phase delta connection earthed in the middle of phases) Single-phase/-wire MAT 40xMx MAT 40xMx Three-phase/-wire 0V A MAT 40xMx Three-phase/4-wire (star connection) * OETIO * ircuit breaker ircuit breaker * EXAMPLE Single-phase/-wire 0V A MAT 40xMx Three-phase/4-wire 0V A MAT 404Mx Single-phase/-wire 0/0V A MAT 40xMx *. For TT system, in order to ensure safe failure mode at TOV due to earth fault on high-voltage systems, connect between terminal and of the MAT. *. For TT system, in order to ensure safe failure mode at TOV due to earth fault on high-voltage systems, install a four-pole (three-pole plus neutral) circuit breaker. *. For single-phase/-wire system, connect lines to terminal and of the MAT. For single-phase/-wire system, connect the neutral line to terminal of the MAT. ALARM OUTPUT When the alarm output is to be transmitted remotely via outdoor cables, a surge protector for the signal line is required. MAT SIFIATIOS ES-864 Rev.0 Page 4/5
5 EXTERAL DIMESIOS & TERMIAL ASSIMETS unit: mm (inch) MODEL: MAT 50 (.97) 5 (.59) 5 (.59) 5 M5 SREW TERMIAL OVER* 80 (.5) 60 (.6) SIFIATIO DI RAIL 5mm wide (.04) 98 (.86) 80 (.5) 5 (.59) MOITOR LED ALARM OUTPUT ** TERMIAL [.4 (.)].5 (.49) 45 (WIRE ISERTIO ALE) * Open/close type. ** Only for code A. SHEMATI IRUITRY Monitor LED Alarm Output ircuit : Thermal breaker ote: Terminals, & are available for '' code 'A.' The schematic shows the relay contact status of a thermal trip or power off. Specifications are subject to change without notice. MAT SIFIATIOS ES-864 Rev.0 Page 5/5
MODEL MAT MODEL MAT3-240 MODEL
ISTRUTIO MAUAL LIHTI SURE PROTETOR FOR THREE-PHASE POWER SUPPLY MAT BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you
More informationMODEL MAT MAT MODEL MAT2-240 MAT2-440
ISTRTIO MAAL LIHTI SRE PROTETOR FOR THREE-PHASE POWER SPPLY BEFORE SE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any
More informationMODEL: MAKF. Lightning Surge Protectors for Electronics Equipment M-RESTER
MODEL: Lightning Surge Protectors for Electronics Equipment M-RESTER OE-PORT SURE PROTECTOR FOR POWER SUPPLY USE Functions & Features Designed to protect electronics equipment from induced lightning surges
More informationMODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER
MODEL: MDTC Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR THERMOCOUPLE USE (ultra-slim) Functions & Features High discharge current capacity 0 ka ( / 0 μs),
More informationMODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)
MODEL: MDST Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR STANDARD SIGNAL LINE (ultra-slim) Functions & Features High discharge current capacity 0 ka ( / 0μs),
More informationMODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER
Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network
More informationMODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER
Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationMODEL: 40DN. Digital Panel Meters 40 Series
Digital Panel Meters 40 Series LOOP POWERED DIGITAL PANEL METER (4 digits, process meter) Functions & Features 4 digit (±9999) loop powered panel meter No external power source needed Scaling function
More informationMODEL: 47LYV. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 1/2 digit, process meter, LED display type) Functions & Features 4 ½ digit DC input digital panel meter 1/8 DIN size Moving average function
More informationMDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester
These modular distribution panel protectors for three phase power systems are designed to prevent damage to electrical distribution systems from mainsborne transient voltages which can occur as the result
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationMODEL: 43AL1. Digital Panel Meters 43 Series
Digital Panel Meters 43 Series LOOP POWERED DIGITAL PANEL METER (process meter) Functions & Features Loop powered -1999 to 9999 compact digital meter Scaling function Screwless spring terminal 24 (.94)
More informationCurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.
CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring
More informationCONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection
CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationMODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationMODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC
MODEL: M1EX 2 Channel Super-mini Signal Conditioners with Display M1E Series SIGNAL TRANSMITTER (2 channels, PC programmable) Functions & Features Converts DC input from a sensor into a standard process
More informationR: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.
Tower Light Series CC-Link TOWER LIGHT (0 mm dia., layers) Functions & Features Lighting, blinking and buzzing are controllable with PLC. Bi-color lighting available in fourth layer Separable tension clamp
More informationMODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to
More informationDANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.
Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,
More informationSurge Protective Devices. STV100K Series. Instruction Manual
Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage
More informationSurge Protective Devices. STV100K Series. Instruction Manual
Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage
More informationMODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC
2 Channel Super-mini Signal Conditioners with Display M1E Series POTENTIOMETER TRANSMITTER (2 channels, PC programmable) Functions & Features Potentiometer s zero/span points can be captured by onsite
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationSurge Protection Devices Type 1+2
Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement
More informationMODEL: GR8-EM. Communication Adaptor GR8 Series
Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to
More informationUltra Slim Relays 24
Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest
More informationSurge & Filter Protection Addressing your industrial power quality needs.
Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationDatasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations
Datasheet SPD II 1 Surge Protectors for A Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations Weidmuller s SPD II 1 series transient voltage surge protectors consist of a range
More informationSurge Protective Device
Surge Protective Device LED Light / Machine protection SPD Class 2 LT-C34G801W General Information LT-C and LT-HC series Surge Protective Devices are for protection of indirect lightning. They are designed
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationSurge Protection for Low Voltage Power Systems
Surge Protection for Low Voltage Power Systems 2017 CATALOG Table of Contents About Raycap 3 Introduction 5 Regulatory Standards 6 Surge Protective Device Components & Terminology 8 Low Voltage Power Distribution
More informationSurge Protective Devices. STV25K Series. Instruction Manual
Surge Protective Devices STV25K Series Instruction Manual Contents 1.0 Installation & Operation... 4 1.1 Environment... 4 1.2 Mechanical Dimensions... 4 1.3 DIN Rail Mounting... 5 1.4 Supplemental Enclosures...
More informationNEW. Datasheet. SPD II and SPD III AC Surge Protector
Datasheet and I AC EW The range of surge protectors are used for transient surge protection of single and multi-phase power circuits at the main electrical panel. Is are for the protection of individual
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationData sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!
-CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions
More informationMINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationSurge Protective Device
SURGE PROTECTIVE DEVICE Surge Protective Device 20 R 320 Type Max. discharge current Imax/Iimp (ka) Number of poles (P) R: with alarm auxiliary contact Blank: without alarm auxiliary contact Max. continuous
More informationDAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS
These commodities/technical data are controlled for export by the U.S. State Department. They may not be transferred, transshipped on a noncontinuous voyage, or otherwise be disposed of outside of the
More information2U Congestion Alert Rack Insert for UK
2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,
More informationPGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater
More informationNEW surge protective devices
NEW surge protective devices For use in low-voltage systems For overhead power lines and buildings Made in EU ABOUT COMPANY INTRODUCTION Company ELEKTROMEHANIKA & BB d.o.o. was established from recent
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationG3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend
Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures
More informationBSPD Surge Protective Devices
BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features
More information3 Design of the electrical installation protection system
J - Protection against voltage surges in LV 3 Design of the electrical To protect an electrical installation in a building, simple rules apply for the choice of b (s); b its protection system. 3.1 Design
More informationMODEL: R2K-1 SEN TRONIC AG. R2K Series
1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission
More informationPGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-6100 PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 2-C-050818 Copyright 2018 Littelfuse All rights reserved. Document
More informationSPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters
The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by
More informationOPTIMISED LUMINAIRE PROTECTION
OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction
More informationPHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic
More informationModular surge protective devices (SPDs)
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Modular surge protective devices (SPDs) CONTENTS Page 1. General
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationSpecifications, Installation, and Operating Instructions
Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.
More informationSINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA
SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4 TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST
More informationE2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1
Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the
More informationLow voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016
Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave
More informationDAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS
REPETER (SIN-NET, M-us use) MODEL DL MODEL & SUFFIX CODE SELECTION MODEL CLE & PORT TYPE : Twisted-pair cable, ports : Fiber optics (PCF), ports Twisted-pair cable, port 5 : Fiber optics (I-50 nm), port
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationPower Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1
Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high
More informationType CBW58 Thermal Circuit Breaker Push to Reset Standard Profile
Specifications: Amperage Range: 3A - 50A Voltage: 125 / 250 VAC, 50 VDC Frequency: 50-60 Hz Dielectric Strength: 1,500 VAC / 1 Minute Interrupting Rating: 3-50A 1000A @ 125/250VAC 3-30A 400A @ 125/250
More informationSPM Series Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationPhotovoltaic System Components Connection And Protection
Photovoltaic System Components Connection And Protection 2018 EDITION Typical Applications ISL Series ISA Series AC ELECTRICAL PANEL Safety Remote Circuit Breaker ISB Series AC ELECTRICAL PANEL AC Surge
More informationOPTIMISED LUMINAIRE PROTECTION
OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction
More informationHUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)
HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...
More informationApplication Techniques CENTERLINE 2100 Motor Control Centers
POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationSECTION DISTRIBUTION SWITCHBOARDS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 26 24 11 This section specifies the furnishing, installation, and connection of the distribution switchboards. 1.2 RELATED WORK: A. Section 13 05 41, SEISMIC RESTRAINT
More informationLightning & Surge Protection
Watchful Eye olutions, Inc. WTH-120, WTH-165/... Class I eries Lightning & urge rotection www.watchfuleyesolutions.com The Guardian that rotects Your AC ower upply ystem against urge and Lightning WTH-165/G/1-255
More informationRelays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection
Q Series Q Series PB elays Switches & Pilot Lights Display Lights IDE Q relays are low-profile, PB relays that provide quality within a compact package. Size equals value. Q relays are small, yet maintain
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationRESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)
Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30
More informationMODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series
Digital Panel Meters 40 Series RTD INPUT DIGITA PANE METER (4 digits, process meter) Functions & Features 4 digit (±9999) panel meter functions igh visible, 0.8" (20.3mm) high and bright ED 48 (1.89) mm
More informationInstruction Manual: IM E
Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering
More informationSPM Series. Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More informationNV disconnectors with fuses
NV disconnectors with fuses Horizontal fuse-switch disconnector type HVL size 00,, 2, and 4a Description Horizontal fuse-switch disconnector type HVL are designed to be used in most demanding fields of
More information16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever
Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationLiebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System
Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationMODEL: CND. Multiplex Transmission System
POW RUN SA1 SA2 MODEL: CND Multiplex Transmission System ADAPTOR CONNECTOR Functions & Features Simplifies wiring wk between multiplex transmission units (DLA1) and 10-RACK, 15-RACK and signal conditioner
More informationFerraz Shawmut TPMOV Principles and Operation
TPMOV Origin Due to recent changes in the Underwriters Laboratories Standard for Safety for Surge Protective Devices UL 1449 additional requirements have been instituted to maintain listings of Surge Protective
More informationModular surge protective devices (SPDs) Cat. Nos :
Contents Page 1. General characteristics...2 2. Overall dimensions...4 3. Technical characteristics...4 4. Conformity...9 5. Mounting...9 6. Accessories.............................11 Product information
More informationVAL-CP-1S-175. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationSlim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay
More informationPT 3-PB-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode
More informationPHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 102777_en_03 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More information