MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER

Size: px
Start display at page:

Download "MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER"

Transcription

1 MODEL: MAT Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTI SURE PROTETOR FOR THREE-PHASE POWER SUPPLY Functions & Features onnected in parallel between the power and earth lines regardless of load current Applicable to single phase /-wire and threephase /4- wire system High discharge current capacity 0 ka or 40 ka (8/0 μs) Degraded head element is automatically separated from the power lines by the incorporated thermal breaker, and the LED lamp (turns off) and the relay contact alerts the failure status. omplies with IE 664- lass II Typical Applications Low-voltage distribution board ombination with installation for large load current 50 (.97) 60 (.6) 98 (.86) mm (inch) MODEL: MAT 40[]M[] ORDERI IFORMATIO ode number: MAT-40[]M[] Specify a code from below for each [] through []. (e.g. MAT-40MY) ORATIOAL VOLTAE 40: 40 V A [] ALARM OUTPUT A: With Y: Without EERAL SIFIATIOS onstruction: Standalone; terminal access at the front Degree of protection: IP0 (If the solderless terminals are covered with insulation tubes.) Surge protection type: Voltage limiting type one-port SPD onnection Line: M5 screw terminal (torque:.5 m) : Tension clamp Applicable wire size Line: See the drawing below. : 0. to.5 mm (8 mm exposed) Screw terminal Line: ickel-plated steel : Tin-plated copper alloy Housing material: Flame-resistant resin (black) : SPDT relay contact trips when the thermal breaker operates. OUTPUT TERMIAL ormal: Open Failure or power off: lose OUTPUT TERMIAL ormal: lose Failure or power off: Open Rated load: 50 V A (resistive load) 4 V A (resistive load) Safety function: Thermal breaker incorporated Monitor LED: reen LED turns on during normal condition and turns off during failure condition, power off or the thermal breaker operating. Applicable Solderless Terminal Size diameter d B T F d : M5 use B.0 mm F 7.0 mm (F 8. mm for sharing terminals) T.8 mm [] POWER SYSTEM : Single-phase /-wire, Three-phase -wire 4: Single-phase /-wire, Three-phase /4-wire MAXIMUM DISHARE URRET M: 0kA (8/0 μsec.) ISTALLATIO Operating temperature: -5 to +55 ( to F) Operating humidity: 5 to 95 %RH (non-condensing) Mounting: DI Rail Weight: 00 g (0.66 lb) MAT SIFIATIOS ES-864 Rev.0 Page /5

2 MODEL: MAT RFORMAE Response time: nanoseconds ( 0 nanoseconds for to ) Insulation resistance: 00 MΩ with 500 V D (line to alarm output) Dielectric strength: 000 V minute (line to alarm output) MODEL MAT-40 MAX. OTIUOUS ORATI VOLTAE (Uc) Between lines: 40 V A to : 0 V A DISHARE VOLTAE (Vmin) Between lines: 400V to : 550V VOLTAE PROTETIO LEVEL (Up) 500 ORATIOAL VOLTAE RAE * (50 / 60Hz) -phase/-wire, -phase/-wire: 90 40V A -phase/-wire: 90 / 80 0 / 40V A -phase/4-wire: 70 40V A MODEL MAT-40 Line to Line MAX. LEAKAE ALARM OUTPUT WITH WITHOUT to ma * 6mA * Other sections ma ma to 0µA 0µA *. MAT is operational as an SPD despite the voltage less than the minimum. However, the functions of the monitor LED and the alarm output are not guaranteed. *. Approx. A *. Approx. A MODEL MAX. DISHARE URRET (Imax) OMIAL DISHARE URRET (In) MAT-40xMx 0kA (8/0µsec) 0kA (8/0µsec) STADARDS & APPROVALS EU conformity: Low Voltage Directive E 664- RoHS Directive E 5058 Surge protection: IE 664- lass II E 664- lass II MAT SIFIATIOS ES-864 Rev.0 Page /5

3 MODEL: MAT OETIO EXAMPLES ISTALLATIO EXAMPLES: Three-phase 4-wire connection ) * ) 4) * 5)a L L L * Residual urrent ircuit Breaker ) : Protective of the switchgear ) : ircuit breaker ) : Main earth terminal or busbar 4) : MAT 5) : Earth conductor 5)a and/or 5)b 6) : EB : Main's earth electrode ED : Switchgear's earth electrode 5)b 6) *4 EB ) ED *. The circuit breaker or the fuse as disconnectors must be installed. Molded-case circuit breaker (MB) or residual current circuit breaker with overcurrent protection (RD) can be used. The rated interrupting capacity of the circuit breaker must be greater than the highest amount of current that could be available in the circuit. Install MB (rated current 0 0A) that has element for each phase. Or RD with protection from nuisance tripping against transit voltages type or time-delay overcurrent protection type is recommended. Recommended sensitivity current rating: 0mA *. able length between the branch point and the earthing: 0.5 meters or less recommended *. The protected 's metal enclosure must be cross-wired to the earth terminal of the MAT. If the protected has no earth terminal, earth only the MAT. *4. In order to protect an electronic circuit such as measuring equipment or communication equipment, we recommend to use surge protectors which have serial impedance incorporated such as M-System's models MAX, MMA, MAH. MAT SIFIATIOS ES-864 Rev.0 Page /5

4 MODEL: MAT OETIO EXAMPLES BY POWER SYSTEMS Abnormal voltages appearing in case of a light load or a fault earth loop must be within the maximum continuous operational voltage when selecting the MAT models. POWER SYSTEM Single-phase/-wire Three phase/-wire (delta connection) () ircuit breaker () ircuit breaker OETIO * * EXAMPLE POWER SYSTEM Single-phase/-wire 0V A Single-phase/-wire 0V A Single-phase/-wire (three-phase delta connection earthed in the middle of phases) Single-phase/-wire MAT 40xMx MAT 40xMx Three-phase/-wire 0V A MAT 40xMx Three-phase/4-wire (star connection) * OETIO * ircuit breaker ircuit breaker * EXAMPLE Single-phase/-wire 0V A MAT 40xMx Three-phase/4-wire 0V A MAT 404Mx Single-phase/-wire 0/0V A MAT 40xMx *. For TT system, in order to ensure safe failure mode at TOV due to earth fault on high-voltage systems, connect between terminal and of the MAT. *. For TT system, in order to ensure safe failure mode at TOV due to earth fault on high-voltage systems, install a four-pole (three-pole plus neutral) circuit breaker. *. For single-phase/-wire system, connect lines to terminal and of the MAT. For single-phase/-wire system, connect the neutral line to terminal of the MAT. ALARM OUTPUT When the alarm output is to be transmitted remotely via outdoor cables, a surge protector for the signal line is required. MAT SIFIATIOS ES-864 Rev.0 Page 4/5

5 EXTERAL DIMESIOS & TERMIAL ASSIMETS unit: mm (inch) MODEL: MAT 50 (.97) 5 (.59) 5 (.59) 5 M5 SREW TERMIAL OVER* 80 (.5) 60 (.6) SIFIATIO DI RAIL 5mm wide (.04) 98 (.86) 80 (.5) 5 (.59) MOITOR LED ALARM OUTPUT ** TERMIAL [.4 (.)].5 (.49) 45 (WIRE ISERTIO ALE) * Open/close type. ** Only for code A. SHEMATI IRUITRY Monitor LED Alarm Output ircuit : Thermal breaker ote: Terminals, & are available for '' code 'A.' The schematic shows the relay contact status of a thermal trip or power off. Specifications are subject to change without notice. MAT SIFIATIOS ES-864 Rev.0 Page 5/5

MODEL MAT MODEL MAT3-240 MODEL

MODEL MAT MODEL MAT3-240 MODEL ISTRUTIO MAUAL LIHTI SURE PROTETOR FOR THREE-PHASE POWER SUPPLY MAT BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you

More information

MODEL MAT MAT MODEL MAT2-240 MAT2-440

MODEL MAT MAT MODEL MAT2-240 MAT2-440 ISTRTIO MAAL LIHTI SRE PROTETOR FOR THREE-PHASE POWER SPPLY BEFORE SE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any

More information

MODEL: MAKF. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MAKF. Lightning Surge Protectors for Electronics Equipment M-RESTER MODEL: Lightning Surge Protectors for Electronics Equipment M-RESTER OE-PORT SURE PROTECTOR FOR POWER SUPPLY USE Functions & Features Designed to protect electronics equipment from induced lightning surges

More information

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER MODEL: MDTC Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR THERMOCOUPLE USE (ultra-slim) Functions & Features High discharge current capacity 0 ka ( / 0 μs),

More information

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable) MODEL: MDST Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR STANDARD SIGNAL LINE (ultra-slim) Functions & Features High discharge current capacity 0 ka ( / 0μs),

More information

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network

More information

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast

More information

MODEL: 40DN. Digital Panel Meters 40 Series

MODEL: 40DN. Digital Panel Meters 40 Series Digital Panel Meters 40 Series LOOP POWERED DIGITAL PANEL METER (4 digits, process meter) Functions & Features 4 digit (±9999) loop powered panel meter No external power source needed Scaling function

More information

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: 47LYV. Digital Panel Meters 47 Series Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 1/2 digit, process meter, LED display type) Functions & Features 4 ½ digit DC input digital panel meter 1/8 DIN size Moving average function

More information

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester These modular distribution panel protectors for three phase power systems are designed to prevent damage to electrical distribution systems from mainsborne transient voltages which can occur as the result

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

MODEL: 43AL1. Digital Panel Meters 43 Series

MODEL: 43AL1. Digital Panel Meters 43 Series Digital Panel Meters 43 Series LOOP POWERED DIGITAL PANEL METER (process meter) Functions & Features Loop powered -1999 to 9999 compact digital meter Scaling function Screwless spring terminal 24 (.94)

More information

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs. CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC MODEL: M1EX 2 Channel Super-mini Signal Conditioners with Display M1E Series SIGNAL TRANSMITTER (2 channels, PC programmable) Functions & Features Converts DC input from a sensor into a standard process

More information

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. Tower Light Series CC-Link TOWER LIGHT (0 mm dia., layers) Functions & Features Lighting, blinking and buzzing are controllable with PLC. Bi-color lighting available in fourth layer Separable tension clamp

More information

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to

More information

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death. Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,

More information

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage

More information

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage

More information

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC 2 Channel Super-mini Signal Conditioners with Display M1E Series POTENTIOMETER TRANSMITTER (2 channels, PC programmable) Functions & Features Potentiometer s zero/span points can be captured by onsite

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 2216-S Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional

More information

Surge Protection Devices Type 1+2

Surge Protection Devices Type 1+2 Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement

More information

MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: GR8-EM. Communication Adaptor GR8 Series Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

Surge & Filter Protection Addressing your industrial power quality needs.

Surge & Filter Protection Addressing your industrial power quality needs. Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Datasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations

Datasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations Datasheet SPD II 1 Surge Protectors for A Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations Weidmuller s SPD II 1 series transient voltage surge protectors consist of a range

More information

Surge Protective Device

Surge Protective Device Surge Protective Device LED Light / Machine protection SPD Class 2 LT-C34G801W General Information LT-C and LT-HC series Surge Protective Devices are for protection of indirect lightning. They are designed

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Surge Protection for Low Voltage Power Systems

Surge Protection for Low Voltage Power Systems Surge Protection for Low Voltage Power Systems 2017 CATALOG Table of Contents About Raycap 3 Introduction 5 Regulatory Standards 6 Surge Protective Device Components & Terminology 8 Low Voltage Power Distribution

More information

Surge Protective Devices. STV25K Series. Instruction Manual

Surge Protective Devices. STV25K Series. Instruction Manual Surge Protective Devices STV25K Series Instruction Manual Contents 1.0 Installation & Operation... 4 1.1 Environment... 4 1.2 Mechanical Dimensions... 4 1.3 DIN Rail Mounting... 5 1.4 Supplemental Enclosures...

More information

NEW. Datasheet. SPD II and SPD III AC Surge Protector

NEW. Datasheet. SPD II and SPD III AC Surge Protector Datasheet and I AC EW The range of surge protectors are used for transient surge protection of single and multi-phase power circuits at the main electrical panel. Is are for the protection of individual

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web:  -   [! -CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions

More information

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka) MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and

More information

PGR-3200 MANUAL INSULATION MONITOR

PGR-3200 MANUAL INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN

More information

Surge Protective Device

Surge Protective Device SURGE PROTECTIVE DEVICE Surge Protective Device 20 R 320 Type Max. discharge current Imax/Iimp (ka) Number of poles (P) R: with alarm auxiliary contact Blank: without alarm auxiliary contact Max. continuous

More information

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS These commodities/technical data are controlled for export by the U.S. State Department. They may not be transferred, transshipped on a noncontinuous voyage, or otherwise be disposed of outside of the

More information

2U Congestion Alert Rack Insert for UK

2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,

More information

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

NEW surge protective devices

NEW surge protective devices NEW surge protective devices For use in low-voltage systems For overhead power lines and buildings Made in EU ABOUT COMPANY INTRODUCTION Company ELEKTROMEHANIKA & BB d.o.o. was established from recent

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

BSPD Surge Protective Devices

BSPD Surge Protective Devices BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features

More information

3 Design of the electrical installation protection system

3 Design of the electrical installation protection system J - Protection against voltage surges in LV 3 Design of the electrical To protect an electrical installation in a building, simple rules apply for the choice of b (s); b its protection system. 3.1 Design

More information

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series 1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission

More information

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-6100 PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 2-C-050818 Copyright 2018 Littelfuse All rights reserved. Document

More information

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by

More information

OPTIMISED LUMINAIRE PROTECTION

OPTIMISED LUMINAIRE PROTECTION OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

Modular surge protective devices (SPDs)

Modular surge protective devices (SPDs) 128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Modular surge protective devices (SPDs) CONTENTS Page 1. General

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

Specifications, Installation, and Operating Instructions

Specifications, Installation, and Operating Instructions Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.

More information

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4 TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016 Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave

More information

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS REPETER (SIN-NET, M-us use) MODEL DL MODEL & SUFFIX CODE SELECTION MODEL CLE & PORT TYPE : Twisted-pair cable, ports : Fiber optics (PCF), ports Twisted-pair cable, port 5 : Fiber optics (I-50 nm), port

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1 Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high

More information

Type CBW58 Thermal Circuit Breaker Push to Reset Standard Profile

Type CBW58 Thermal Circuit Breaker Push to Reset Standard Profile Specifications: Amperage Range: 3A - 50A Voltage: 125 / 250 VAC, 50 VDC Frequency: 50-60 Hz Dielectric Strength: 1,500 VAC / 1 Minute Interrupting Rating: 3-50A 1000A @ 125/250VAC 3-30A 400A @ 125/250

More information

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Photovoltaic System Components Connection And Protection

Photovoltaic System Components Connection And Protection Photovoltaic System Components Connection And Protection 2018 EDITION Typical Applications ISL Series ISA Series AC ELECTRICAL PANEL Safety Remote Circuit Breaker ISB Series AC ELECTRICAL PANEL AC Surge

More information

OPTIMISED LUMINAIRE PROTECTION

OPTIMISED LUMINAIRE PROTECTION OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

Thermal-Magnetic Circuit Breaker 4220-T...

Thermal-Magnetic Circuit Breaker 4220-T... Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With

More information

SECTION DISTRIBUTION SWITCHBOARDS

SECTION DISTRIBUTION SWITCHBOARDS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 26 24 11 This section specifies the furnishing, installation, and connection of the distribution switchboards. 1.2 RELATED WORK: A. Section 13 05 41, SEISMIC RESTRAINT

More information

Lightning & Surge Protection

Lightning & Surge Protection Watchful Eye olutions, Inc. WTH-120, WTH-165/... Class I eries Lightning & urge rotection www.watchfuleyesolutions.com The Guardian that rotects Your AC ower upply ystem against urge and Lightning WTH-165/G/1-255

More information

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection Q Series Q Series PB elays Switches & Pilot Lights Display Lights IDE Q relays are low-profile, PB relays that provide quality within a compact package. Size equals value. Q relays are small, yet maintain

More information

Residual Current Devices drcm Digital

Residual Current Devices drcm Digital Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.

More information

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Residual Current Devices FRCdM Type B, B+ and Bfq Digital Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka) Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30

More information

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series Digital Panel Meters 40 Series RTD INPUT DIGITA PANE METER (4 digits, process meter) Functions & Features 4 digit (±9999) panel meter functions igh visible, 0.8" (20.3mm) high and bright ED 48 (1.89) mm

More information

Instruction Manual: IM E

Instruction Manual: IM E Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering

More information

SPM Series. Plug-in Surge Protection

SPM Series. Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

NV disconnectors with fuses

NV disconnectors with fuses NV disconnectors with fuses Horizontal fuse-switch disconnector type HVL size 00,, 2, and 4a Description Horizontal fuse-switch disconnector type HVL are designed to be used in most demanding fields of

More information

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,

More information

Surge Protection Devices Ex9UE2

Surge Protection Devices Ex9UE2 Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,

More information

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

MODEL: CND. Multiplex Transmission System

MODEL: CND. Multiplex Transmission System POW RUN SA1 SA2 MODEL: CND Multiplex Transmission System ADAPTOR CONNECTOR Functions & Features Simplifies wiring wk between multiplex transmission units (DLA1) and 10-RACK, 15-RACK and signal conditioner

More information

Ferraz Shawmut TPMOV Principles and Operation

Ferraz Shawmut TPMOV Principles and Operation TPMOV Origin Due to recent changes in the Underwriters Laboratories Standard for Safety for Surge Protective Devices UL 1449 additional requirements have been instituted to maintain listings of Surge Protective

More information

Modular surge protective devices (SPDs) Cat. Nos :

Modular surge protective devices (SPDs) Cat. Nos : Contents Page 1. General characteristics...2 2. Overall dimensions...4 3. Technical characteristics...4 4. Conformity...9 5. Mounting...9 6. Accessories.............................11 Product information

More information

VAL-CP-1S-175. Extract from the online catalog. Order No.:

VAL-CP-1S-175. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

PT 3-PB-ST. Extract from the online catalog. Order No.:

PT 3-PB-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 102777_en_03 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information