D90 Plus. Sub-cycle distance protection and advanced automation controller. Multilin

Size: px
Start display at page:

Download "D90 Plus. Sub-cycle distance protection and advanced automation controller. Multilin"

Transcription

1 Key Benefits 90 Plus Sub-cycle distance protection and advanced automation controller Secure sub-cycle distance protection to improve system stability and increase line loading True VT filter improves distance protection performance without intentional delays or reduced fault coverage Superior phase selection algorithm ensures secure high speed single pole tripping Reliable and secure protection on lines equipped with series compensation pplications Overhead lines including series compensated lines and underground cables of various voltage levels Single and dual-breaker circuits requiring single pole/ three-pole autoreclosing and independent synchrocheck supervision Backup protection for generators, transformers and reactors Features Protection and ontrol Secure time-domain algorithm providing sub-cycle distance protection. Phase istance with independent compensation settings for in-zone power transformers Ground distance with independent self and mutual zero sequence compensation Out-of-step tripping and power swing blocking irectional overcurrent: Phase, neutral and negative sequence Wattmetric zero-sequence directional power Under/Over frequency Synchronism check for dual breaker applications Single/three-pole four-shot dual breaker auto-recloser ustomization of protection and control functions with independent protection FlexLogic, Flexurves, and Flexlements dvanced automation controller with independent automation prograable logic. Bay control through front panel HMI Multilin Large color HMI with metering, event records and control. Fault and disturbance recording, including internal relay operating signals at up to 128 samples/cycle Built-in phasor measurement unit streaming synchrophasors as per I onfigurable alarm annunciator eliminates the need for separate annunciator panel True sub-cycle tripping with apacitively oupled Voltage Transformers (VT) ircuits with in-zone power transformers and tapped transformer feeders Wide area system monitoring and control using integrated protection and synchrophasor measurement Monitoring and Metering ontinuous monitoring of input channels Metering - current, voltage, frequency, power, energy and synchrophasors as per I Transient recorder samples/cycle, 1 minute or more of storage capacity isturbance recorder 1 sample/cycle, 5 minutes or more of storage capacity vent recorder time tagged events, with 0.5 ms scan of digital inputs omprehensive display of metering, phasors, maintenance and fault information via the front panel. nervista Software Integrated software for configuration and coissioning Literature and software toolset to ensure reference material and device utilities are up-to-date ounications Multiple protocols - I61850, NP 3.0 Level 2, Modbus RTU, Modbus TP/IP, I Up to three independent IP addresses Front USB port for high speed counications 194

2 90 Plus Line istance Protection System igital larm nnunciator 96 customizable alarms in multiple pages liminates the need for separate annunciator Intuitive HMI ustomizable Bay diagrams for various applications Local control and status indication of breakers & disconnect switches Local/Remote control Fault, event, disturbance and transient reports dvanced Protection Sub-cycle distance protection 512 lines of Protection 1 msec execution dvanced utomation ontroller Built-in prograable logic engine dvanced Math, Boolean and ontrol operations dvanced ounication apabilities Up to three thernet ports I61850, NP3, MOBUS TP/IP, I protocols I synchrophasors over thernet Front USB port for high speed data transfer dvanced Recorders liminate the need for stand-alone disturbance recorders 128 samples/cycle, 1 min duration transient recorder Seperate ynamic disturbance recorder for recording long term events Synchrophasors PMU recording dvanced disturbance recorder eliminates stand-alone FR and Phasor Measurement Unit Integrated Bay ontroller and intuitive HMI eliminates stand-alone HMI and controller igital fault recorder suary with the latest information on the events, faults, transients and disturbances. ontrol screen for the preconfigured bay with breaker & disconnect control in multiple pages using dedicated pushbuttons in the front panel

3 Protection and ontrol Modern power systems are under increasing constraints in their ability to transmit power from generation facilities to major load centers, and are forced to operate closer to their natural stability limits. Under these conditions, the critical clearing angle and corresponding critical clearing time become progressively smaller and there is an increasing need to minimize the fault clearing time on these constrained circuits. The 90Plus is ideally suited for application on circuits where fast fault detection and small breaker failure margin are required. The 90Plus allows transmission limits to be maintained or even increased while respecting the transient stability limits of the power system. 90 Plus Sub-cycle istance Protection The 90Plus sub-cycle distance algorithm employs a combination of energy-based integrator/comparators and high-speed phase comparators to determine if a fault is internal or external. The energy integrator algorithm uses both the magnitude of the operating and polarizing signals as well as the relative phase information to provide fast, secure operation for obvious internal faults. The high-speed phase comparators examine the angular relationship between operating and polarizing signals independent of magnitude to provide greater security in the presence of VT transients. For faults with low SIR or close-in high magnitude faults, the 90 Plus can provide trip times under ½ cycle for phase-phase faults and between ½ to ¾ of a cycle for ground faults. apacitive oupled Voltage Transformer Transient Filter Transients generated by apacitive oupled Voltage Transformers (VT) tend to have relatively significant magnitudes and long durations. The impact of these transients is particularly pronounced when protecting transmission lines where the Source Impedance Ratio (SIR), the ratio between the system equivalent impedance and the relay reach impedance, is large. The voltage signals are crucial for proper operation of a distance element, but become significantly distorted by transient components that are generated but the VT. This presents a significant challenge particularly for fast impedance protection algorithms. Generally, VT transients will cause the magnitude of the voltage signal to be underestimated, causing distance elements to overreach. Most relays Phase istance Operating Times Ground istance Operating Times Phase istance lement; VT Filter nabled and Tuned Ground istance lement; VT Filter nabled and Tuned Functional Block iagram Monitoring 50 LOS NSI VI NUMBRS N FUNTIONS 79 TRIP 50P (2) 50_2 (2) 51P (2) 51_2 (2) 50BF (2) 21P (4) 67P (2) 67_2 (2) 68 Pilot Schemes 90 Plus Line istance Protection System 59 Flexlement T M G (2) 51G (2) Metering 50N (2) 51N (2) 67N/G (2) 21G (4) Transducer Inputs 59P 27P (2) 59N 25 (2) NSI evice Numbers & Functions evice Number Function 21G Ground istance 21P Phase istance 25 Synchronism heck 27P Phase Undervoltage 27 uxiliary Undervoltage 50BF Breaker Failure 50 urrent isturbance etector 50G Ground Instantaneous Overcurrent 50N Neutral Instantaneous Overcurrent 50P Phase Instantaneous Overcurrent 50_2 Negative Sequence Instantaneous Overcurrent 51G Ground Time Overcurrent 51N Neutral Time Overcurrent 51P Phase Time Overcurrent 51_2 Negative Sequence Time Overcurrent 52 ircuit Breaker 59N Neutral Overvoltage 59P Phase Overvoltage 59 uxiliary Overvoltage 59_2 Negative Sequence Overvoltage 67N Neutral irectional Overcurrent 67P Phase irectional Overcurrent 67_2 Negative Sequence irectional Overcurrent 68 Power Swing Blocking 78 Out-of-Step Tripping 79 utomatic Recloser 81 U/O Under and over frequency 196

4 detect VT transients under high SIR and incorporate an intentional operating delay on the distance elements to ridethrough the period with VT transients. ynamically reducing the reach of the distance elements to prevent them from overreaching is another strategy to cope with VT transients. The 90Plus introduces a true digital filter into the voltage signal path that removes distortions generated by the VT, resulting in a signal that is a more accurate reproduction of the power system voltage. The 90Plus is then able to provide sub-cycle distance protection in the presence of VT transients, without adding intentional delays or reducing fault coverage. The 90Plus sub-cycle distance algorithm is secure and sufficiently fast for a wide range of power system scenarios. The VT filter increases the speed of operation of the 90Plus for an even wider range of contingencies. ustom Prograable Logic esigner 90 Plus user prograable protection logic and independent automation logic allows the users to build custom protection and automation schemes. s with all filters, the 90Plus VT filter needs to be tuned to a specific application, so that the behaviour of the VT is characterized and reduced to 3 critical parameters that become settings for the relay. VT Transient for Fault at Voltage Maximum and orrected Voltage Signal VT Transient for Fault at Voltage Zero-crossing and orrected Voltage Signal Fast Breaker Failure Reset With stability limits shrinking, the ability to achieve fast breaker failure resetting times becomes more challenging to achieve. When the total worst-case clearing time including breaker failure starts to approach cycles, often there is little more than 1 cycle margin left to allow for breaker failure protections to reset. The 90Plus provides fully independent breaker failure protection for breakerand-a-half or ring bus arrangements with consistent sub-cycle resetting times (5/8 of a power system cycle), allowing for shorter critical clearing times and increased line loading. ven with T saturation, current reversal and severe subsidence, the URPlus breaker failure element provides secure, dependable protection with consistent subcycle reset times In-Zone transformer ompensation Phase distance elements in the 90 Plus can be used to detect faults through different types of three-phase wye/ delta transformers, allowing application of the 90 Plus for backup protection at generating stations, VTs and Ts can be installed independently of each other on either side of the power transformer. The relay automatically compensates for transformer connections for accurate far-reaching stepped distance backup protection schemes Series-ompensated Lines The 90 Plus provides enhanced stability and security by employing an adaptive distance reach control to cope with the overreaching and sub-synchronous oscillations when applied to, or in the vicinity of, series compensated lines. epending on the needs of the application, the relay can be prograed to dynamically be self-polarized or use memory voltage for polarization for additional security. Single-Pole Tripping The 90 Plus relay uses a highly secure and dependable phase selection algorithm that provides fast and accurate fault type identification. convenient trip function is built-in to coordinate actions of the key protection and teleprotection operands in single-pole tripping applications

5 ounication ided (Pilot) Schemes The 90 Plus supports several coon teleprotection schemes for coordinated fault clearance within the zone of protection. The following types of pilot-aided schemes are available in the 90 Plus : irect Under reach Transfer Trip (UTT) Permissive Under reach Transfer Trip (PUTT) Permissive Overreach Transfer Trip (POTT) Hybrid Permissive Overreach Transfer Trip (HYB POTT) permissive echo and transient blocking logic incorporated irectional comparison blocking scheme (B) irectional comparison unblocking scheme (UB) To support single pole tripping applications, up to four bits can be keyed from the various teleprotection schemes. Multiple Breaker the specific requirements of a given application without requiring auxiliary components and wiring. Using Protection FlexLogic, the 90 Plus can be prograed to provide required tripping logic along with custom scheme logic for breaker control, transfer tripping schemes for remote breakers and dynamic setting group changes. utomation FlexLogic features math, Boolean and control functions that can be employed in advanced load shedding, load restoration and dynamic volt/var control schemes. Scalable Hardware The 90 Plus is available with a multitude of I/O configurations to suit a variety of application needs. The expandable modular design allows for easy configuration and future upgrades. igital outputs include trip-rated Form- and Solid State Relay (SSR), available with optional circuit continuity monitoring and current detection to monitor the health of downstream circuits like breaker trip coils. Monitoring and Metering The 90 Plus includes detailed metering and recording for all signals. Voltage, current, and power metering are built into the relay as a standard feature. urrent and voltage parameters are available as total RMS magnitude, and as fundamental frequency magnitude and angle. Transient Recorder high resolution (128 samples/cycle) transient recorder with 1 minute or more of storage capacity is provided to record short duration system events like faults and reclosing sequences. isturbance Recorder n independent disturbance recorder with a 5 minute storage capacity intended to record long duration events like power swings and voltage sags and swells. Sequence of vent Recorder dvanced vent Recorder with the capability to store up to 8000 events. The 90 Plus supports multi-breaker busbar configurations such as breaker-and-a-half or ring bus arrangements, providing dual breaker auto reclose, dual synch-check elements, and dual independent Breaker Failure elements. 90 Plus ual Breaker onfiguration VT1 1PH T1 B1 B2 T2 dvanced utomation The 90 Plus incorporates advanced automation features including powerful FlexLogic (user prograable logic) independent for protection and automation schemes. ombined with the counication capabilities, the 90 Plus provides an advanced, highly flexible platform for substation automation applications. The 90 Plus integrates seamlessly with other relays for distributed applications like interlocking and special protection schemes. 90 Plus SR1 Synchrochek 1 SR2 BF1 SR1 SR3 SR3 BF2 SR2 ISTN and OVRURRNT 3PH VT2 FlexLogic FlexLogic is the integral 90 Plus platform prograing logic engine that facilitates customizing the relay protection to meet PROTT LIN 90 Plus supports dual breaker configurations. Two Ts can be measured individually and logically sued within the relay

6 Information for all three recorders can be accessed either through the front panel HMI or through nervista TM Launchpad Software. The very high sampling rate and large amount of storage capacity available for data recording in the 90 Plus can eliminate the need for installing standalone recording equipment. ounications The 90 Plus p r o v i d e s for secure remote data and engineering access, making it easy and flexible to use and integrate into new and existing infrastructures. Fiber optic thernet provides high-bandwidth counications allowing for low-latency controls and highspeed file transfers of relay fault and event record information. The availability of three independently configurable thernet option provides the means of creating fault tolerant counication architectures in an easy, cost-effective manner. The 90 Plus supports the most popular industry standard protocols enabling easy, direct integration into S systems. I61850 NP3.0 I Modbus RTU, Modbus TP/IP Interoperability with mbedded I61850 The 90 Plus with integrated I61850 can be used to lower costs associated with protection, control and automation. G Multilin s leadership in I61850 comes from thousands of installed devices and follows on Multilin s extensive development experience with U 2.0. Replace expensive copper wiring between devices with direct transfer of data using GOOS messaging onfigure systems based on I61850 and also monitor and troubleshoot them in real-time with nervista Viewpoint ngineer Integrate G Multilin Is and generic I61850-compliant devices seamlessly in nervista Viewpoint Monitoring nervista TM Software The nervista Suite is an industry-leading set of software programs that simplifies every aspect of using the 90 Plus relay. The nervista TM suite provides all the tools to monitor the status of your the protected asset, maintain the relay, and integrate information measured by the 90 Plus into S or S monitoring systems. onvenient OMTR and Sequence of vents viewers are an integral part of the UR Plus Setup software included with every UR Plus relay, to carry out postmortem event analysis to ensure proper protection system operation. nervista Launchpad nervista Launchpad is a powerful software package that provides users with all of the setup and support tools needed for configuring and maintaining G Multilin products. The setup software within Launchpad allows configuring devices in real-time by counicating using serial, thernet, or modem connections, or offline by creating setting files to be sent to devices at a later time. Included in Launchpad is a document archiving and Power System Troubleshooting The UR Plus setup software contains many tools and reports that simplify and reduce the amount of time required for troubleshooting power nalyze transmission line faults using system voltage, current and appropriate pickup flags that are measured & recorded up to 128 samples/cycle. View characteristic shapes for phase and ground distance, power swing and load encroachment elements View the operation of the internal 90 Plus inputs and outputs with time-stamped accuracy

7 management system that ensures critical documentation is up-to-date and available when needed. ocuments made available include: Manuals pplication Notes Guideform Specifications Brochures Wiring iagrams FQ s Service Bulletins Viewpoint ngineer front panel of the device eliminating the need for separate annunciators in the relay panel. The status of any contact or remote input or internally generated Flexlogic TM operand can be assigned to the annunciator. The annunciator can display 12/24/48 targets per page to a maximum of 8 pages. separate self-test message page on the annunciator panel shows error messages and troubleshooting advice. - Metering - Bay ontrol - Fault Reports - Sequence of vent Reports - Transient Records Suaries - isturbance Record Suaries - Real Time Phasor isplays of Voltage, urrent and Sequence components Viewpoint ngineer is a set of powerful tools that will allow you to configure and test UR relays at a system level in an easy-touse graphical drag-and-drop environment. Viewpoint ngineer provides the following configuration and coissioning utilities: Tabular display of metering values. Graphical Logic esigner Graphical System esigner Graphical Logic Monitor 12 to 48 user configurable alarms per page eliminates the need for separate annunciator. Graphical System Monitor HMI User Interface The 90 Plus provides local HMI capability through two color L display panels. One serves as a digital annunciator and the other optional HMI is for display and control functions. nnunciator The 90 Plus provides an embedded, configurable color L annunciator on the omprehensive data visualization. Single line diagrams for bay monitoring and control User pushbuttons can be assigned to several functions through multiple menu levels Local/Remote ontrol Pre-prograed comprehensive displays for: Sequence of event records with the ability to view time difference between two events for troubleshooting and analysis. Front Panel USB The front panel of the 90 Plus provides a USB 2.0 host for field laptop connections for high-speed data transfer and making downloading and uploading faster than an RS232 connection. Bay onfigurations The 90 Plus supports customizable single-line diagrams along with 12 pre-configured diagrams and corresponding controls for each bay-level equipment. Breaker-and-half configuration ouble Bus configuration Single Bus onfiguration Two-Main and Transfer Bus configuration 200

8 Typical Wiring iagram g Multilin 90 Plus Line istance Protection System 201

9 General Specifications urrent T rated secondary: Relay burden: onversion range: syetrical urrent withstand: Voltage 1 to 5 < 0.2 V ar rated secondary 0.02 to 46 x T rating RMS 20 ms at 250 times rated 1 sec. at 100 times rated ontinuous at 3 times rated VT rated primary: 50.0 to V VT ratio: 1.00 to Relay burden: < 0.25 V at 120 V onversion range: 1 to 275 V Voltage withstand: ontinuous at 260 V to neutral 1 min./hr at 420 V to neutral ontact Inputs Input rating: Selectable threshholds: Maximum current: IRIG-B Input mplitude modulation: shift: Input impedance: Isolation: Form- Relay 300 V dc maximum 20 to 250 V 10 ma during turn-on 0.5 ma steady state 1 to 10 Vpk-pk TTL 50 kω 2 kv Make and carry for 0.2 s: 30 per NSI arry continuous: 6 Break at L/R of 40 ms: dc at 125 Vdc dc at 250 Vdc Operate time: < 4 ms ontact material: Silver alloy Solid State Relay Make and carry for 0.2 s: 30 as per NSI arry ontinuous: 6 Break at L/R of 40 ms: 10.0 dc at 250 Vdc Operate time: < 100 µs ritical Failure Relay Make and carry for 0.2 s: arry continuous: Break at L/R of 40 ms: Operate time: ontact material: Power Supply Nominal voltage: Min/max voltage: Nominal voltage: Min/max voltage: Voltage withstand: Voltage loss hold-up: Power consumption: dc at 125 Vdc dc at 250 Vdc 0.10 dc at 125 V < 8 ms Silver alloy ontrol Power xternal Output (For dry contact input) apacity: Isolation: Front USB Standard: 125 to 250 Vdc 80/300 Vdc 100 to 240 Vac at 50/60 Hz 80/275 Vac at 48 to 62 Hz 2 x Highest nominal Voltage for 10 ms 1 sec. at 100 times rated 200 ms duration at nominal Typical-30 V; Max-65 V 100 m dc at 48 V dc 2 kv Type B USB connector supporting setup software Rear RS to 115 kbps supporting Modbus RTU & NP3.0 istance: 1200 m Isolation: 2 kv thernet Ports Standard: 10/100Base-T: Optional: 100Base-F: Power budget: Max optical input power: Max optical output power: Receiver sensitivity: Typical distance: SNTP clock synchronization error: 1 port supporting Modbus RTU and NP 3.0 RJ45 connector 2 ports supporting NP3.0, I , or I61850 on counications card 1300 nm, multi-mode, half-duplex/full-duplex, fiber optic with ST connector 10 db -14 dbm -20 dbm -30 dbm 2.0 km <10 ms (typical) pprovals UL listed for the US and anada manufactured under an ISO9000 registered system. : LV 73/23/:I M 81/336/:M , N imensions 202

10 Ordering Interface Front Panel Language 90P - * * - * * ** * * * - * * * * * ** * * * * escription H nnunciator (Standard) + HMI nglish (Standard) Features Protection utomation ounications Metering FR quipment Manager S S S P L U S S 3-pole istance (Standard) 3-pole istance + Tele Protection + FlexLogic 1/3-pole Sub-cycle istance + Series ompensation + Tele- Protection + FlexLogic Breaker ontrol + Synchrocheck (Standard) + utomation FlexLogic ModBus TP/IP + ModBus Serial + NP 3.0 (Standard) + ModBus TP/IP + I ModBus TP/IP + I NP 3.0 TP/IP + ModBus TP/IP + I I Basic Metering (Standard) + Synchrophasors + ata Logger + ata Logger + Synchrophasors Transient Recorder + Sequence of vents (Standard) + isturbance Recorder ircuit Breaker/ounication Statistics + Battery Monitor (Standard) Hardware Harsh nvironment oating Power Supply H None (Standard) Harsh nvironment onformal oating High (88-275V/80-300VI) (Standard) Peer-to-Peer ounications Module None (Standard) ounication Module Type Module Type 01 Type 02 I/O Module Type I Type IB Type I Type I Type I Type IF B F B F B F B F B F None (Standard) ual ST fiber & copper 5 VT & 7 T (5 mp current) (Standard) 5 VT & 7 T (1 mp current) None 8 Inputs, 4 Form- Outputs with Voltage + urrent Monitoring (Standard) 8 Inputs, 4 Solid State Outputs with Voltage + urrent Monitoring 8 Inputs, 4 Form- Outputs 4 Inputs, 8 Form- Outputs 23 Inputs 12 Form- Outputs Order ode xample: 90P - H - 04 U S - H B 01 Note: The order code is for a 90 Plus with Sub-cycle distance protection, front panel HMI, advanced automation features, dual redundant IP counications, transient & disturbance recorders with the appropriate I/O cards for dual configurations. ccessories for the 90 Plus MultiLink thernet Switch ML2400-F-HI-HI G1 Viewpoint ngineer VP-1 Viewpoint Maintenance VPM-1 Viewpoint Monitoring I61850 VP Visit to: View Guideform specifications ownload the instruction manual Review applications Notes and support documents Buy a 90 Plus online v11

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating Advanced Line Differential Protection, Automation, and Control System Combine subcycle line protection with traveling-wave fault locating Subcycle differential and distance protection minimizes damage

More information

A low-cost, economical solution for distribution feeder protection

A low-cost, economical solution for distribution feeder protection SEL-351A Protection System A low-cost, economical solution for distribution feeder protection Achieve sensitive and secure fault detection using comprehensive protection functions. Track breaker status

More information

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control Protection, Automation, and Control System Combine subcycle line protection with complete substation bay control Subcycle distance protection minimizes damage and expensive repairs on transmission lines.

More information

Advanced distribution feeder solution with integrated protection, monitoring, and control

Advanced distribution feeder solution with integrated protection, monitoring, and control Protection System Advanced distribution feeder solution with integrated protection, monitoring, and control Achieve sensitive and secure fault detection using comprehensive protection functions. Keep track

More information

g Energy Multilin Voltage Regulator Controller DGCV KEy BENEFITS APPLICATIONS FEATURES Metering & Monitoring Voltage Regulation Communications

g Energy Multilin Voltage Regulator Controller DGCV KEy BENEFITS APPLICATIONS FEATURES Metering & Monitoring Voltage Regulation Communications Multilin Voltage Regulator DGCV KEy BENEFITS Increases grid efficiency by optimizing voltage regulation Through deployment of the Volt/VAR system, the Multilin DGCV: - Enables up to a 6% reduction in energy

More information

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Line differential protection RED670 Relion 670 series Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,

More information

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay Bus Differential and Breaker Failure Relay A Powerful Solution for Busbar Differential Protection Features and Benefits Select the for the differential protection of busbar systems with up to 18 terminals.

More information

UR Plus Series. Revision 1.73 Release Notes. GE Digital Energy. Overview. GE Publication Number: GER Summary. Copyright 2013 GE Multilin Inc.

UR Plus Series. Revision 1.73 Release Notes. GE Digital Energy. Overview. GE Publication Number: GER Summary. Copyright 2013 GE Multilin Inc. G Digital nergy UR Plus Series Revision 1.73 Release Notes G Publication Number: GR-4372 Copyright 2013 G Multilin Inc. Overview Summary Release 1.73 of the UR Plus series introduces product-specific and

More information

C90 Plus. Multilin AUTOMATION CONTROL SYSTEM APPLICATIONS FEATURES KEY BENEFITS

C90 Plus. Multilin AUTOMATION CONTROL SYSTEM APPLICATIONS FEATURES KEY BENEFITS Multilin C90 Plus AUTOMATION CONTROL SYSTEM KEY BENEFITS Powerful automation controller eliminates the need for separate substation prograable logic controller High-end load shedding with multiple stages

More information

UR Universal Relay Series

UR Universal Relay Series G Digital nergy UR Universal Relay Series Revision 5.80 Release otes G Publication umber: GR-4377 Copyright 2010 G Multilin Summary Overview G Multilin issues the UR 5.80 release that introduces new improvements

More information

Bus Bar Protection Relay B-PRO 4000

Bus Bar Protection Relay B-PRO 4000 Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation

More information

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830 DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830 PC83 and PC830 series devices are designed to perform the relay protection functions and 6-154 kv networks automation, have different functionality

More information

GE Multilin 350 Feeder Protection Relay Specifications

GE Multilin 350 Feeder Protection Relay Specifications GE Multilin 350 Feeder Protection Relay Specifications The feeder protection relay shall provide primary protection of medium voltage distribution feeders. The relay shall be equipped with the following

More information

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics SIL-A Overcurrent and Earth Fault Relay for Primary and Secondary Distribution Main characteristics The SIL-A is an overcurrent and earth fault protection relay for primary and secondary distribution with

More information

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series Substation Automation Products Line distance protection REL670/650 Relion 670 and 650 series For maximum reliability of your power system REL670 and REL650 line distance protection IEDs (Intelligent Electronic

More information

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Two independent, simultaneously operating recorders in one package Triggering on input quantities and calculated values, such as

More information

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering. MIN II Key Benefits Reduce troubleshooting and maintenance cost - event recording, and analogy/digital oscillography Design flexibility - Easy to use programming logic Access to information - Modbus RTU

More information

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES Introduction The supply of electrical energy occupies an important position in the life of modern society. Operation of commerce, industry, transport,

More information

Multilin P30 Phasor Data Concentrator

Multilin P30 Phasor Data Concentrator Multilin P30 Phasor Data Concentrator Secure high performance Phasor Data Concentrator (PDC) for wide area monitoring and dynamic disturbance analysis KEY BENEFITS Reduce deployment and operation cost

More information

KEY BENEFITS APPLICATIONS FEATURES

KEY BENEFITS APPLICATIONS FEATURES KEY BENEFTS Easily meet stability requirements - sub-cycle trip time (average of 0.75 power cycle, maximum 1 power cycle) Dependable and secure - Performance backed up by many years of field experience

More information

MiCOM P521. Fast Feeder Differential Protection

MiCOM P521. Fast Feeder Differential Protection 01 Fast Feeder Differential Protection The relay provides high-speed two-ended current differential unit protection of overhead lines and underground cables in applications such as ring mains and parallel

More information

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution

More information

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network SIL-G Feeder & Generator Protection Relay RC FLSH Main characteristics The SIL-G is a relay for primary distribution which can protect a feeder by means of current and voltage functions. It is also provided

More information

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS Armando Guzmán Schweitzer Engineering Laboratories, Inc. Pullman, WA 99163 A reliable power system maintains frequency and voltage

More information

MiCOM P521. Fast feeder differential protection

MiCOM P521. Fast feeder differential protection 01 Fast feeder differential protection The relay provides high-speed two-ended current differential unit protection of overhead lines and underground cables in applications such as ring mains and parallel

More information

UR Universal Relay Series

UR Universal Relay Series G Digital nergy UR Universal Relay Series Revision 5.61 Release otes G Publication umber: GR-4320rev2 Copyright 2008 G Multilin Summary Overview G Multilin issues the UR 5.61 release that introduces new

More information

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin F650 - More than Feeder Protection & Control F650 Bay Controller A Comprehensive Protection and Control solution for Transmission and Distribution Networks 2 Introduction: What is the F650? Protection,

More information

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Recloser Controller for feeder protection and automation siemens.com/distribution-automation SIPROTEC 7SC80 Control Controller for feeder protection and automation siemens.com/distribution-automation SIPROTEC 7SC80 Control Designed for feeder automation applications This solution allows very fast

More information

UR Universal Relay Series

UR Universal Relay Series GE Digital Energy UR Universal Relay Series Revision 4.43 Release Notes GE Publication Number: GER-4380Rev1 Copyright 2010 GE Multilin Summary Overview GE Multilin issues the UR 4.43 release that introduces

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system SEL-451 Protection, Automation, and Bay Control System Advanced feeder protection and complete substation bay control in one economical system Customize distribution protection using multiple instantaneous,

More information

UR Universal Relay Series

UR Universal Relay Series G Digital nergy UR Universal Relay Series Revision 5.24 Release otes G Publication umber: GR-4387rev1 Copyright 2010 G Multilin Summary Overview G Multilin issues the UR 5.24 release that introduces new

More information

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators. SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

High-speed transformer differential protection for up to five terminals

High-speed transformer differential protection for up to five terminals Transformer Protection Relay High-speed transformer differential protection for up to five terminals Advanced differential protection and three restricted earth fault (REF) elements minimize damage and

More information

g Energy Multilin Recloser Controller DGCR Communications Protection Automation & Control Security & EnerVista Software Hardware Metering & Monitoring

g Energy Multilin Recloser Controller DGCR Communications Protection Automation & Control Security & EnerVista Software Hardware Metering & Monitoring Multilin Recloser Controller DGCR Key Benefits 4 shot auto-recloser 3 setting groups enable different setting selections based on switched conditions Advanced logic engine and multiple IOs for creating

More information

UR Universal Relay Series

UR Universal Relay Series GE Digital Energy UR Universal Relay Series Revision 3.50 Release Notes GE ublication Number: GER-4432 Copyright 2009 GE Multilin Overview Summary GE Multilin issues the UR 3.50 release that introduces

More information

UR Universal Relay Series

UR Universal Relay Series GE Digital Energy UR Universal Relay Series Revision 5.90 Release otes GE Publication umber: GER-4401 Copyright 2010 GE Multilin Summary Overview GE Multilin issues the UR 5.90 release that introduces

More information

Built for speed, security, and simplicity

Built for speed, security, and simplicity Time-Domain Line Protection Built for speed, security, and simplicity Traveling-wave-based and incremental-quantity-based line protection schemes as fast as ms with traditional pilot channels and over

More information

Multilin 850 YEAR. Innovative Feeder Protection System for Industrial and Utility Feeder Applications. Innovative Technology & Design

Multilin 850 YEAR. Innovative Feeder Protection System for Industrial and Utility Feeder Applications. Innovative Technology & Design Multilin 850 Innovative Feeder Protection System for Industrial and Utility Feeder Applications The Multilin 850 relay is a member of the Multilin 8 Series protective relay platform and has been designed

More information

Power System Monitoring Recorder

Power System Monitoring Recorder Power System Monitoring Recorder TESLA 4000 Model 4000 Model 4003 Product Overview TESLA 4000 is an easy-to-use and cost effective, state of the art, multi-time frame (simultaneous) power system monitoring

More information

EPM Multilin ADVANCED POWER QUALITY METER. High Performance Power Quality and Transient Recorder Meter KEY BENEFITS APPLICATIONS FEATURES

EPM Multilin ADVANCED POWER QUALITY METER. High Performance Power Quality and Transient Recorder Meter KEY BENEFITS APPLICATIONS FEATURES Multilin EPM 9900 ADVANCED POWER QUALITY METER High Performance Power Quality and Transient Recorder Meter KEY BENEFITS Auto-calibrating metrology means the meter maintains its accuracy over temperature

More information

Version 7.7x Release Notes

Version 7.7x Release Notes GE Grid Solutions UR Family Version 7.7x Release Notes GE Publication Number: GER-4834A opyright 2018 GE Multilin Inc. Overview This document contains the release notes for firmware and software versions

More information

NPW800R RETROFITTING. Power and Volatge Protection Relay

NPW800R RETROFITTING. Power and Volatge Protection Relay RETROFITTING Power and Volatge Protection Relay NPW800R (R3 case) is dedicated to the refurbishment of CEE WTG 7000 relays (R3 case) providing the measurement of apparent (S), active (P) and reactive (Q)

More information

MiCOM Agile P746. Grid Solutions. Key Benefits. Numerical Busbar Protection. A Combination of Speed, Security and Selectivity. About MiCOM P40 Agile

MiCOM Agile P746. Grid Solutions. Key Benefits. Numerical Busbar Protection. A Combination of Speed, Security and Selectivity. About MiCOM P40 Agile GE Grid Solutions MiCOM Agile P746 Numerical Busbar Protection The MiCOM Agile P746 centralized numerical busbar protection provides complete protection for all voltage levels up to extra voltage busbar

More information

750/760 Feeder Management Relay Instruction Manual

750/760 Feeder Management Relay Instruction Manual GE Digital Energy 750/760 Feeder Management Relay Instruction Manual Software Revision: 7.4x Manual P/N: 1601-0120-AK Manual Order Code: GEK-106471T GE Digital Energy 650 Markland Street Markham, Ontario

More information

PROTECTION, AUTOMATION & CONTROL

PROTECTION, AUTOMATION & CONTROL PROTECTION, AUTOMATION & CONTROL 1. DTIVA The members of the DTIVA product line are configured to protect and control the elements of not solidly grounded radial networks. Here the application of Petersen

More information

Using the Bitronics 70 Series to Improve Local Monitoring and Control

Using the Bitronics 70 Series to Improve Local Monitoring and Control Automate a Substation and Preserve the Electromechanical Relay Investment Part Two of Four Using the Bitronics 70 Series to Improve Local Monitoring and Control Paul Grabowski - Bitronics Senior Application

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation ABB Oy Distribution Automation July 1, 2009 1MRS756504 B Slide 1 Contents RED615 Technical Presentation

More information

Transformer Protection Relay

Transformer Protection Relay Transformer Protection Relay T-PRO Product Overview The IEC 61850 station bus embedded T-PRO relay provides complete three-phase multi-winding transformer protection and overload protection, DFR-quality

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control

FM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control Key Benefits FM2 FEEDER Protection System Economical and compact feeder protection for low voltage feeders Comprehensive low voltage feeder management system - Integrated feeder protection and process

More information

ABB Inc. Substation Automation and Protection Division Coral Springs, FL Allentown, PA. Multi-Zoned Distance

ABB Inc. Substation Automation and Protection Division Coral Springs, FL Allentown, PA. Multi-Zoned Distance ABB ABB Inc. Substation Automation and Protection Division Coral Springs, FL Allentown, PA Descriptive Bulletin September 21 Multi-Zoned Distance Device umber:21/21, 21B, 21P/21P, 2, 27, /, BF, 1/1, Q/1Q,

More information

Current Fault Signatures and Analysis Auto-calibrating metrology means the meter maintains its accuracy over temperature and time

Current Fault Signatures and Analysis Auto-calibrating metrology means the meter maintains its accuracy over temperature and time Multilin EPM 9900 High Performance Power Quality and Transient Recorder Meter The EPM 9900 is one of the most advanced monitoring products on the market today, providing you with the total picture of energy

More information

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. www.siemens.com/protection SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. designed for feeder automation applications This solution allows very fast fault detection

More information

F35. Multilin FEEDER PROTECTION SYSTEM. Cost-effective protection and control for single/multiple distribution feeders KEY BENEFITS APPLICATIONS

F35. Multilin FEEDER PROTECTION SYSTEM. Cost-effective protection and control for single/multiple distribution feeders KEY BENEFITS APPLICATIONS Multilin F35 FEEDER PROTECTON SYSTEM Cost-effective protection and control for single/multiple distribution feeders KEY BENEFTS Cost effective and flexible protection and control device for distribution

More information

Multilink. Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets. Multilin

Multilink. Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets. Multilin Multilink Ethernet Communication switches Ethernet for Industrial Automation, Power Utility, and Traffic Control markets Key Benefits The MultiLink family is a line of Industrial and Substation Hardened

More information

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! The Fiberoptic Communications Specialists The Model 570E offers high-speed serial communication to meet the challenging needs of distribution

More information

g GE Power Management UR - The Universal Relay

g GE Power Management UR - The Universal Relay UR - The Universal Relay UR Features FAMILY of relays built on a common platform Common look & feel for ease of use product to product All bells & whistles, present and future, available to whole family

More information

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution UR An integrated feeder protection and metering solution Power to Manage your Facility Connectivity ModBus RTU MMS/UCA2 TM Protocols SI Compatibility Flexibility FlexCurves FlexLogic The first Relay designed

More information

2 ms arc-flash protection and feeder relay in one platform

2 ms arc-flash protection and feeder relay in one platform Feeder Protection Relay 2 ms arc-flash protection and feeder relay in one platform Combine light sensor inputs with high-speed overcurrent protection to achieve secure arc-flash protection in as fast as

More information

1. Project Description

1. Project Description Page No: 1 of 16 1. Project Description 1.1 Introduction This document outlines protection, monitoring and control requirements for the shared network assets associated with establishment of Tarrone Terminal

More information

Power System Monitoring Recorder. Product Overview. 10 Year WARRANTY

Power System Monitoring Recorder. Product Overview. 10 Year WARRANTY Power System Monitoring TESLA 4000 Product Overview TESLA 4000 is an easy-to-use, state of the art, multi-time frame (simultaneous) power system monitoring recorder. Its integrated Phasor Measurement Unit

More information

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68 The Challenges and Opportunities Faced by Utilities using Modern Protection and Control Systems - Paper Unavailable Trends in Protection and Substation Automation Systems and Feed-backs from CIGRE Activities

More information

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES Multilin EPM 6010 BUILDING AUTOMATION POWER METER BACnet /IP Communications and Energy Measurement KEY BENEFITS Rapid integration into BACnet management systems High accuracy multifunction power meter,

More information

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test: Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

D60. Multilin LINE DISTANCE PROTECTION SYSTEM. High-speed transmission line protection with three/single pole tripping KEY BENEFITS APPLICATIONS

D60. Multilin LINE DISTANCE PROTECTION SYSTEM. High-speed transmission line protection with three/single pole tripping KEY BENEFITS APPLICATIONS Multilin D60 LNE DSTANCE PROTECTON SYSTEM High-speed transmission line protection with three/single pole tripping KEY BENETS High-speed cost effective five zone quad or mho, phase and ground distance protection

More information

Siprotec 7ST61 / 7ST63

Siprotec 7ST61 / 7ST63 Siprotec / Numerical overhead contact line protection for AC traction power supply siemens.de/rail-electrification The numerical overhead contact line protection relay Siprotec / is a selective and quick

More information

C70. Multilin CAPACITOR BANK PROTECTION SYSTEM. Capacitor Banks Protection & Control KEY BENEFITS APPLICATIONS FEATURES

C70. Multilin CAPACITOR BANK PROTECTION SYSTEM. Capacitor Banks Protection & Control KEY BENEFITS APPLICATIONS FEATURES Multilin 70 APATOR BANK PROTETON SYSTEM apacitor Banks Protection & ontrol KEY BENEFTS Protect capacitor banks of a variety of configurations with sensitive current and voltage balance protection functions

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Content REF615 Technical Presentation

Content REF615 Technical Presentation Distribution Automation Relion 615 series Feeder Protection and Control Ver. 2.0 Technical Presentation March 30, 2010 1MRS756407 E Slide 1 Content Technical Presentation highlights March 30, 2010 Slide

More information

Digital Substation Overview of Technology, Industry

Digital Substation Overview of Technology, Industry Digital Substation Overview of Technology, Industry Trends and Standardization Efforts 4th International Scientific & Technical Conference Actual Trends in Development of Power System Protection and Automation

More information

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756407 E Slide 1 Content REF615 Technical Presentation highlights May 13,

More information

Packaged Solutions. Grid Solutions. Value Added Solutions for Protection, Control and Automation Applications. Flexible and Expandable

Packaged Solutions. Grid Solutions. Value Added Solutions for Protection, Control and Automation Applications. Flexible and Expandable Grid Solutions Packaged Solutions Value Added Solutions for Protection, Control and Automation GE s Packaged Solutions provide fully integrated, modular solution sets comprising of engineering, design,

More information

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin Overcurrent and Arc Protection by Reyrolle Alexander Erokhin VAR Partner Day September 20-21, 21, 2017 I Berlin Reyrolle Product Range by SIEMENS Challenges We Meet for our Customers Easy-to-use protection

More information

2008 Many Changes in IEEE C37.2. IEEE Standard Electrical Power System Device Function Numbers, Acronyms and Contact Designations

2008 Many Changes in IEEE C37.2. IEEE Standard Electrical Power System Device Function Numbers, Acronyms and Contact Designations 2008 Many Changes in IEEE C37.2 IEEE Standard Electrical Power System Device Function Numbers, Acronyms and Contact Designations Major revisions first since 1995 Substantial additions 1 - New ten more

More information

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller SEL-3530 Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller Versatile RTAC operates as a supervisory control and data acquisition (SCADA) remote terminal unit

More information

Power System Monitoring Recorder TESLA 3000

Power System Monitoring Recorder TESLA 3000 Power System Monitoring Recorder TESLA 3000 Product Overview TESLA 3000 is an easy-to-use and cost-effective, stateof-the-art, multi-time frame (simultaneous) power system recording monitor. The optional

More information

L90. Multilin LINE CURRENT DIFFERENTIAL SYSTEM. Phase segregated line current differential and distance protection KEY BENEFITS APPLICATIONS FEATURES

L90. Multilin LINE CURRENT DIFFERENTIAL SYSTEM. Phase segregated line current differential and distance protection KEY BENEFITS APPLICATIONS FEATURES Multilin L90 LNE CURRENT DFFERENTAL SYSTEM Phase segregated line current differential and distance protection KEY BENEFTS Phase segregated differential protection ensures secure high-speed single pole

More information

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series Substation Automation Products Transformer protection RET670/650 Relion 670 and 650 series For reliable protection and control of all types of power transformers and reactors The RET670/650 IEDs (Intelligent

More information

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Power Systems Communications Implementation of IEC61850 in a Substation Environment Power Systems Communications Implementation of IEC61850 in a Substation Environment 26 October 2009 Reference VEE4700-01 Revision 0 Document Control Document ID: DOCUMENT1 Rev No Date Revision Details

More information

TWO-WINDING TRANSFORMER DIFFERENTIAL

TWO-WINDING TRANSFORMER DIFFERENTIAL E3-TR PROTECTION WITH AUTOMATIC VOLTAGE Because of the control, measuring and monitoring functions implemented, the IED can also be used as a bay control unit. The EuroCAP configuration tool, which is

More information

DRTS 66 can test all the following relays

DRTS 66 can test all the following relays Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs

More information

F60. Multilin FEEDER PROTECTION SYSTEM. Advanced Protection, Control and Automation for Distribution Feeders KEY BENEFITS APPLICATIONS FEATURES

F60. Multilin FEEDER PROTECTION SYSTEM. Advanced Protection, Control and Automation for Distribution Feeders KEY BENEFITS APPLICATIONS FEATURES Multilin 60 EEDER PROTECTION SYSTEM Advanced Protection, Control and Automation for Distribution eeders KEY BENEITS The most flexible protection and control device for distribution feeder applications

More information

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay The power of fusion. 1874 1886 1893 1899 1906 1908 1911 1934 1962 1963 1976 1983 1990 1999 There s a certain energy at Eaton.

More information

Protection relays.

Protection relays. Protection relays www.vamp.fi Vamp Ltd Vamp Ltd, with a strong experience of designing devices, is an independent supplier of relays and monitoring equipment. The company has an established reputation

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

www. ElectricalPartManuals. com C60 Breaker Management Relay UR Series Instruction Manual GE Industrial Systems C60 Revision: 2.9X

www. ElectricalPartManuals. com C60 Breaker Management Relay UR Series Instruction Manual GE Industrial Systems C60 Revision: 2.9X g GE Multilin 215 Anderson Avenue, Markham, Ontario Canada L6E 1B3 Tel: (905) 294-6222 Fax: (905) 201-2098 Internet: http://www.geindustrial.com/multilin C60 Breaker Management Relay UR Series Instruction

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

RMS Product Presentation

RMS Product Presentation RMS Product Presentation THE RELAY SPECIALISTS relay monitoring systems pty ltd www.rmpl.com.au Relay Monitoring Systems Pty Ltd 6 Anzed Court - Melbourne - Australia Manufacturing in Australia Company

More information

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9 PJM Manual 07: PJM Protection Standards Revision: 3 Effective Date: May 24, 2018 Prepared by System Planning Division Transmission Planning Department PJM 2018 Table of Contents Table of Contents Approval...6

More information

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. D R T S 6 6 THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. www.isatest.com DRTS 66 The new generation of advanced test equipments for relays,

More information

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100% Operating range: 0.10 to 30 xin (step 0.01) 50P(2) Activation level 100% Deactivation level 95% Timer accuracy: 30 ms Operating range: 0.10 to 30 xin (step 0.01) 50N/G(2) Activation level 100% Deactivation

More information

SPECIAL CONSIDERATION OF FEEDER PROTECTION FOR BREAKER-AND-A-HALF CONFIGURA- TIONS. G. Steynberg

SPECIAL CONSIDERATION OF FEEDER PROTECTION FOR BREAKER-AND-A-HALF CONFIGURA- TIONS. G. Steynberg SPECIAL CONSIDERATION OF FEEDER PROTECTION FOR BREAKER-AND-A-HALF CONFIGURA- TIONS G. Steynberg Siemens AG; Energy Sector, Energy Automation, Nuremberg 1. INTRODUCTION The breaker-and-a-half configuration

More information

IDM DATA ACQUISITION SYSTEM

IDM DATA ACQUISITION SYSTEM DATA ACQUISITION SYSTEM The a compact and economical multifunction data acquisition system Rendering all Unrivalled product profile Advanced multifunctional distributed data acquisition system Fully multitasking

More information

Power systems 5: Protection

Power systems 5: Protection Power systems 5: Protection Introduction In this series of articles, we will be looking at each of the main stages of the electrical power system in turn. As you will recall from our Introduction to Electrical

More information

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications Multilin EPM 6100 Energy and Demand Submeter with Wi-Fi The EPM 6100 is a powerful tool that allows customers to monitor and manage their energy usage within factories, businesses and across campuses.

More information