NG series safety switches with solenoid and RFID technology

Size: px
Start display at page:

Download "NG series safety switches with solenoid and RFID technology"

Transcription

1 series safety switches with solenoid and RFID technology These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because of mechanical inertia of pulleys, saw disks, parts under pressure or with high temperatures. Thus, the switches can also be used if individual guards are only to be opened under certain conditions. Maximum safety with a single device The series switches are constructed with redundant electronics. As a result, the maximum PL e and SIL safety levels can still be achieved through the use of a single device on a guard. This avoids expensive wiring in the field and allows faster installation. Inside the control cabinet, the two electronic safety outputs must be connected to a safety module with OSSD inputs or to a safety PLC. Versions with mode (safety outputs active when guard closed and locked) are interlocks with guard locking acc. to ISO ; the product is labelled with the symbol shown. Series connection of several switches One of the most important features of the series is the possibility of connecting up to sensors in series, while still maintaining the maximum safety levels PL e laid down in EN 89 and SIL acc. to EN 0. This connection type is permissible in safety systems which have a safety module at the end of the chain that monitors the outputs of the last switch. The fact that the PL e safety level can be maintained even with sensors connected in series demonstrates the extremely secure structure of each single device. Series connection with other devices DDAF DDAF DDAF Pizzato Elettrica CS series safety module The series features two safety inputs and two safety outputs, which can be connected in series with other Pizzato Elettrica safety devices. This option allows the creation of safety chains containing various devices. For example, stainless steel safety hinges (HX BEE series), transponder sensors (ST series) and door lock sensors ( series) can be connected in series while still maintaining the maximum PL e and SIL safety levels. HX BEE HX BEE DDAF ST DDMKDT DDAF ST DDMKDT Pizzato Elettrica CS series safety module RFID actuators with high coding level The series is provided with an electronic system based on RFID technology to detect the actuator. This allows to provide each actuator with different coding and makes it impossible to tamper with a device by using another actuator of the same series. Millions of different coding combinations are possible for the actuators. They are therefore classified as high level coded actuators, according to EN ISO. Dustproof The switch is provided with a through hole for inserting the actuator. Thanks to this unique feature, any dust that enters the actuator hole can always come out on the opposite side instead of remaining inside. Moreover, the lock pin is provided with a diaphragm seal, making the system suitable for critical environments with a high level of dust. Holding force of the locked actuator The strong interlocking system guarantees a maximum actuator holding force of F max = 970 N. This is one of the highest values currently available on the market today, making this device suitable for heavyduty applications. Integrated control devices The switch is also available with elevated cover. Control devices such as buttons, emergency buttons, indicator lights or selectors can thereby be attached directly to the switch together with corresponding contact blocks. The result is a compact solution with direct access to control devices without needing to install them separately on the switch panel or in their own housing. The devices can be illuminated and, thanks to the PUSHIN springoperated connections, wiring is quick and intuitive. Centring The switch is provided with a wide centring inlet for the actuator pin. This solution makes it easier to align the actuator and the opening hole on the head during installation. Moreover, this solution drastically reduces the probability of a collision between the switch and the actuator, making it possible to install the device even on inaccurately closing doors. Pushin springoperated connections The switch is provided with a PUSHIN type springoperated connection system on the inside. This technology allows wiring to be performed quickly and easily, as the wire just needs to be inserted into the appropriate hole in order to establish the electrical connection and automatically secure the wire. This operation can be performed with rigid or flexible wires with a crimped wireend sleeve and requires no tools. Release is obtained by pressing the appropriate wirereleasing button. General Catalogue Safety 0708

2 Six s for immediate diagnosis As the s have been designed for quick immediate diagnosis, the status of each input and output is highlighted by one specific. This makes it possible to quickly identify the interruption points in the safety chain, which device is released, which door is opened and any errors inside the device. All of this at a glance, without needing to decode complex flashing sequences. Protection against tampering Each actuator of the series is supplied with four protective caps. Not only do the caps prevent dirt from accumulating and simplify cleaning, they also block access to the fastening screws of the actuator. As a result, standard screws can be used instead of tamperproof screws. Holding force of the unlocked actuator The inside of each switch features a device which holds the actuator in its closed position. Ideal for all those applications where several doors are unlocked simultaneously, but only one is actually opened. The device keeps all the unlocked doors in their position with a retaining force of N~, stopping any vibrations or gusts of wind from opening them. Articulated actuator for inaccurately closing doors All series actuators are articulated, thereby allowing the actuator pin to be safely guided into the switch through the centring hole. As a result, the actuator and switch do not need to be precisely aligned during installation. In addition, the device can thereby be used on doors with a minimum actuation radius of 0 mm without the actuation pin needing to be angled. Function for protecting against recoil forces If a door is closed too quickly or with so much force that the recoil would cause it to open again, a special function in the switch prevents locking. This function prevents the immediate locking of the door if the lock signal is applied. This protects the switch against recoil forces that occur during instantaneous locking. This serves to protect the switch from damage and forces the operator to close the door more gently. Head and devices with variable orientation The system can be variably configured by loosening the screws on the head. The key release device and the emergency release button can also be rotated and secured independently of one another in steps of 90. The device can thus assume different configurations. Key release device and emergency release button The key release device (auxiliary release) is used to permit unlocking of the actuator only by personnel in possession of the key. The device also functions with no power supply and, once actuated, prevents the guard from being locked. The emergency release button (escape release) allows actuator release and immediate opening of the door. Generally used in machines within which an operator could inadvertently become trapped, it faces towards the machine interior, to allow the operator to exit even in the event of a power failure. The button has two stable states and can be freely extended in length with suitable extensions (see accessories). Both devices can be positioned on the four sides of the switch. As a result, it can be installed both towards the interior and towards the exterior of the machine. Nondetachable head and release devices The head and the release device can be rotated but cannot be detached from each other. This makes the switch more secure since the problem of incorrect assembly by the installer cannot occur; in addition, the risk of damage is lower (loss of small parts, penetration of dirt, etc.). High protection degree These devices are designed to be used in the toughest environmental conditions and they pass the IP7 immersion test acc. to EN 09. They can therefore be used in all environments where maximum protection degree of the housing is required. Due to their special design, these devices are suitable for use in equipment subjected to cleaning with high pressure hot water jets. These devices meet the IP9K test requirements according to ISO 0 (water jets with 0 bar and 80 C). Two safety output actuation modes Two different activation modes are available for the switch active safety outputs with guard closed and locked (mode ) for machines with inertia or active safety outputs with guard closed (mode ) for machines without inertia. External device monitoring On request, the switch can be supplied with EDM function (External Device Monitoring). In this case, the switch itself checks the proper function of the devices connected to the safety outputs. These devices (usually relays or safety contactors) must send a feedback signal to the EDM input, which checks that the received signal is consistent with the state of the safety outputs. General Catalogue Safety 0708

3 series safety switches with solenoid and RFID technology Selection diagram HEAD TYPE AND OPER ATI PRINCIPLE DD DD D7D D7E Locked actuator with deenergised solenoid with key release Locked actuator with deenergised solenoid with key release and emergency release button Locked actuator with deenergised solenoid with emergency release button Locked actuator with energised solenoid with emergency release button DD Locked actuator with deenergised solenoid DE Locked actuator with energised solenoid ACTUATORS VN F Low level coded actuator VN F High level coded actuator COVER CONFIGURATIONS A C D E F G H CONDUIT ENTRIES Threaded conduit entries M0 product options With M metal male connector K pole, bottom K pole, right K pole, left accessory sold separately With M metal male connector for standalone connection K9 8pole, bottom K9 8pole, right K9 8pole, left With M metal male connector for series connection with Y connectors K90 8pole, bottom K9 8pole, right K9 8pole, left With M metal male connector (clockwise numbering) K900 pole, bottom K90 pole, right K90 pole, left With M metal male connector (clockwise numbering) K0 pole, bottom, configuration K0 pole, bottom, configuration General Catalogue Safety 0708

4 Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options DDAFEK900LP Operating principle DD locked actuator with deenergised solenoid DE locked actuator with energised solenoid DD locked actuator with deenergised solenoid. With key release locked actuator with deenergised DD solenoid. With key release and emergency release button D7D locked actuator with deenergised solenoid. With emergency release button D7E locked actuator with energised solenoid. With emergency release button Inputs and outputs safety inputs, safety outputs, signalling output closed guard signalling output locked guard solenoid activation input I Note Supplied only together with actuator safety inputs, safety outputs, signalling output closed guard signalling output locked guard solenoid activation input I programming input I safety inputs, safety outputs, signalling output closed guard signalling output locked guard solenoid activation input I programming input I feedback input EDM I safety inputs, safety outputs, signalling output closed guard signalling output FAULT solenoid activation input I programming input I Activation of OS outputs mode OS safety outputs active with locked guard mode OS safety outputs active with closed guard Release button length for max. mm wall thickness (standard) LP for max. mm wall thickness LP for max. mm wall thickness LP0 for max. 0 mm wall thickness LP0 for max. 0 mm wall thickness Preinstalled connectors other wall thicknesses on request without connector (standard) K M metal connector, pole, bottom M metal connector, pole, bottom, K0 configuration K900 M metal connector, pole, bottom M metal connector, 8pole, bottom, for K90 series connection M metal connector, 8pole, bottom, for K9 standalone connection other connectors on request For the complete list of possible combinations please contact our technical department. extraction force actuator extraction force N (standard) E F low level coded actuator VN F the switch recognises any type F actuator F high level coded actuator VN F the switch recognises one single type F actuator Cover configurations A C D E F G H actuator freely removable standard cover cover with button / yellow button / emergency button with rotary release cover with button / black button / emergency button with rotary release cover with button / black button cover with green button / red button cover with green button cover with button other configurations on request Code structure for actuator VN F F low level coded actuator the switch recognises any type F actuator F high level coded actuator the switch recognises one single type F actuator General Catalogue Safety 0708

5 series safety switches with solenoid and RFID technology Technical data Housing Metal head and housing, baked powder coating. Three threaded conduit entries M0x. Protection degree IP7 acc. to EN 09 IP9K acc. to ISO 0 Protection degree with control devices IP acc. to EN 09 with cable gland of equal or higher protection degree Main features Actuation without contact, using RFID technology Digitally coded actuator holding force 970 N SIL and PL e with a single device Optional integrated control devices Metal housing, three M0 conduit entries Protection degree up to IP7 and IP9K Versions with key release and emergency release button PL e also with series connection of up to devices Signalling Quality marks UL approval E787 TÜV SÜD approval Z EAC approval RU CIT.AД.В.00 In compliance with standards EN ISO, EN 097, EN 097, IEC 00, EN 00, EN ISO 0, IEC 09, EN 09, EN 00, EN 00, BGGSET, IEC 08, IEC 08, IEC 08, IEC 08, SN 900, EN ISO 89, EN ISO 89, EN 0, EN, EN, EN, ETSI 89, ETSI 89, ETSI 0, UL 08, CSA. No. Compliance with the requirements of Machinery Directive 00//EC EMC Directive 0//EU Directive 0//EU RED FCC Part Connection terminals Connection system PUSHIN spring type Crosssection of rigid/flexible wires w. wireend sleeve min. x 0. mm ( x AWG ) max. x. mm ( x AWG ) Wire crosssection with preinsulated wireend sleeve min. x 0. mm ( x AWG ) x max. x 0.7 mm ( x AWG 8) Cable stripping length (x) min. 8 mm max. mm General data SIL level (SIL CL) up to SIL acc. to EN 0 Performance Level (PL) up to PL e acc. to EN ISO 89 Safety category up to cat. acc. to EN ISO 89 Interlock with lock, no contact, coded type acc. to EN ISO Level of coding acc. to EN ISO low with F actuator High with F actuator Safety parameters MTTF D 88 years PFH D 8.07 E DC High Service life 0 years Ambient temperature 0 C 0 C Max. actuation frequency with actuator lock and release 00 operating cycles/hour Mechanical endurance million operating cycles Max. actuation speed 0. m/s Min. actuation speed mm/s Maximum force before breakage F max 970 N acc. to EN ISO Max. holding force F Zh 700 N acc. to EN ISO Maximum clearance of locked actuator mm Released actuator extraction force N Tightening torques for installation see page see page Electrical data of //I/I/I/EDM inputs Rated operating voltage U e Vdc Rated current consumption I e ma Electrical data of / safety outputs Rated operating voltage U e Vdc Output type PNP type OSSD Maximum current per output I e 0. A Minimum current per output I m 0. ma Thermal current I th 0. A Utilization category DC; U e = Vdc, I e =0. A Short circuit detection Yes Overcurrent protection Yes Internal selfresettable protection fuse. A Duration of the deactivation impulses at the safety outputs < 0 µs Permissible maximum capacitance between outputs < 00 nf Permissible maximum capacitance between output and ground < 00 nf Response time upon deactivation of / inputs typically 7 ms, max. ms Response time upon actuator removal typically ms, max. 00 ms Electrical data of / signalling output Rated operating voltage U e Output type Maximum current per output I e Utilization category Short circuit detection Overcurrent protection Internal selfresettable protection fuse RFID sensor data Assured operating distance S ao Assured release distance S ar Rated operating distance S n Repeat accuracy Differential travel Max. switching frequency Vdc PNP 0. A DC; U e = Vdc, I e =0. A No Yes. A mm mm (actuator not locked) mm (actuator locked). mm % s n 0 % s n Hz Power supply electrical data Rated operating voltage U e SELV Vdc ±% Operating current at U e voltage minimum ma with activated solenoid 0. A with activated solenoid and all outputs at maximum power. A Rated insulation voltage U i Vdc Rated impulse withstand voltage U imp. kv External protection fuse. A /. A type F or equivalent device Overvoltage category III Electrical endurance million operating cycles Solenoid duty cycle 0% ED (continuous operation) Solenoid consumption 9 W max. 7 General Catalogue Safety 0708

6 Features approved by UL Features approved by TÜV SÜD Utilization categories Vdc, 0. A (resistive load). In compliance with standard UL 08, CSA. No. Protection degree Ambient temperature Storage temperature PL, category SIL Please contact our technical department for the list of approved products. In compliance with standards 00//EC, EN 097 /0, EN 097 /0, EN 097 0, EN ISO, EN 08 (SIL ), EN 08 0 (SIL ), EN 08 0 (SIL ), EN 08 (SIL ), EN 0/0 (SIL CL ), EN ISO (PL e, cat. ). Inputs supplied by remote class source or limited voltage and limited energy IP7, IP9K 0 C 0 C C 7 C PL e, cat.. SIL / SIL CL Please contact our technical department for the list of approved products. Selection table for switches with high level coded actuators Mode OS safety outputs active with locked and closed guard Mode OS safety outputs active with closed guard Operating principle D, with Operating principle D, emergency release button with key release and and sealable auxiliary emergency release button release device Operating principle D, with sealable auxiliary release device Operating principle E Operating principle D, with key release Operating principle E, with emergency release button DDAF DEAF DDAF DDAF D7DAF D7EAF DDAF DEAF DDAF DDAF D7DAF D7EAF To order a product with EDM input replace number with number in the codes shown above. Example DDAF DDAF Selection table for switches Mode OS safety outputs active with locked and closed guard Mode OS safety outputs active with closed guard Operating principle D, with Operating principle D, emergency release button with key release and and sealable auxiliary emergency release button release device Operating principle D, with sealable auxiliary release device Operating principle E Operating principle D, with key release Operating principle E, with emergency release button DDA DEA DDA DDA D7DA D7EA DDA DEA DDA DDA D7DA D7EA To order a product with EDM input replace number with number in the codes shown above. Example DDA DDA Legend interlock with lock monitoring acc. to EN ISO Selection table for actuators Level of coding acc. to EN ISO Article low VN F high VN F General Catalogue Safety 0708 The use of RFID technology in series devices makes them suitable for several applications. Pizzato Elettrica offers two different versions of actuators, in order to best suit customers specific needs. Type F actuators are all encoded with the same code. This implies that a device associated with an actuator type F can be activated by other actuators type F. Type F actuators are always encoded with different codes. This implies that a device associated with an actuator type F can be activated only by a specific actuator. Another F type actuator will not be recognised by the device until a new association procedure is carried out (reprogramming). After reprogramming, the old actuator F will no longer be recognized. The D and D files are available at Items with code on green background are stock items 8

7 series safety switches with solenoid and RFID technology Complete safety system The use of complete and tested solutions guarantees the electrical compatibility between the series switches and the safety modules from Pizzato Elettrica, as well as high reliability. The switches have been tested with the modules listed in the adjacent table. VN F Vcc Pizzato Elettrica CS series safety module Switches Compatible safety modules Instantaneous safety contacts Safety module output contacts Delayed safety contacts Signalling contacts CS AR0 NO / NC CS AR0 NO / NC CS AR08 NO / / CS AT0 NO NO NC CS AT NO NO / CS MP page CS MF page 8 All series switches can be connected to safety modules or safety PLCs with OSSD inputs provided compatibility is ensured in advance. series switches can be used as individual devices provided that the safety outputs be evaluated by a Pizzato Elettrica safety module (see table for combinable safety modules). Vcc Vcc VN F VN F VN F VN F VN F VN F Pizzato Elettrica CS series safety module PLC Pizzato Elettrica CS MP series programmable safety module Possibility of series connection of multiple switches for simplifying the wiring of the safety system, whereby only the outputs of the last switch are evaluated by a Pizzato Elettrica safety module (see table with compatible safety modules). Each series switch is provided with two signalling outputs which are activated when the guard is closed () or locked (). Depending on the specific requirements of the system that has been realised, the signals of the signalling outputs can be evaluated by a PLC. Possibility of series connection of multiple switches for simplifying the wiring of the safety system, whereby only the outputs of the last switch are evaluated by a Pizzato Elettrica safety module of the CS MP series. Both the safetyrelevant evaluation and the evaluation of the signalling outputs are performed by the CS MP series. The examples listed above refer to applications with Internal block diagram CODE ACT f EDM f I LOCK f IN f OUT f f0 PWR A The diagram on the side represents the logic functions which Function interact inside the device. PWR Power supply / selfdiagnosis Function f0 is a basic function and includes the monitoring of the power supply as well as internal, cyclical tests. Function f monitors IN status of safety inputs the status of the device inputs, whereas function f monitors the OUT status of safety outputs presence of the actuator within the detection areas of the switch. ACT actuator state Function f checks the actuator lock condition. LOCK actuator locked Function f is intended to activate or deactivate the safety outputs state of EDM inputs and check for any faults or short circuits in the outputs. EDM ( D ) In the EDM versions, the f function verifies the consistency of the EDM signal during safety output state changes. The safetyrelated function, which combines the subfunctions mentioned above, only activates the safety outputs for the switches in mode if the input signals are correctly applied and the actuator pin is in the safe actuation area in the head and locked. The safety outputs for switches in mode are activated if the input signals are correctly applied and the actuator pin is in the safe actuation area in the head. The status of each function is displayed by the corresponding (PWR, IN, OUT, ACT, LOCK, EDM), in such a way that the general device status becomes immediately obvious to the operator. General Catalogue Safety 0708

8 Actuation sequence in mode PWR ACT PWR ACT PWR ACT PWR ACT PWR ACT IN LOCK IN LOCK IN LOCK IN LOCK IN LOCK OUT OUT OUT OUT OUT The switch is supplied with power (PWR on, green), the and inputs are enabled (IN on, green), the and safety outputs are disabled (OUT off). The actuator is outside of the actuation zone ( ACT off). When the actuator is brought inside the safe actuation area (dark grey area), the switch turns on the ACT (green). In this position, the signalling output (doorclosed) is activated. The actuator is not locked (LOCK off). The I input can be used to lock the actuator (LOCK on, green). The and safety outputs are enabled (OUT on, green). The signalling output is activated at the same time. The safe actuation area is extended in order to allow greater play for the actuator. The I input can be used to unlock the actuator (LOCK off). The switch disables the and safety outputs and turns off the OUT. The signalling output is deactivated at the same time. The safe actuation area returns to the initial values. When the actuator leaves the actuation limit area, the device turns off the ACT and the signalling output. Actuation sequence in mode In contrast to the above mode description, the safety outputs and enable when the actuator is detected, and disable when the actuator is no longer detectable. Operating states PWR IN OUT ACT LOCK EDM (a) Device state OFF Device switched off. POWER Internal tests upon activation. ON Safety inputs of the device not active. Activation of safety inputs. Safety inputs incoherence. Recommended action check for presence and/or wiring of inputs. ERROR ERROR ERROR ERROR in safe area. signalling output active. in safe area and locked; and outputs active. Mode Activation of safety inputs,. in safe area and locked.,, and outputs active. Mode Activation of safety inputs,. in safe area., and outputs active. Error on safety outputs. Recommended action check for any short circuits between the outputs, outputs and ground or outputs and power supply, then restart the device. detection error. Check the physical integrity of the device and, in case of failure, please replace the entire device. If undamaged, realign the actuator with the switch and restart the device. Internal error. Recommended action restart the device. If the failure persists, replace the device. EDM signal active (external relay off) a EDM signal not active (external relay on) a Error in the EDMa function External device monitoring (EDM) The D version, in addition to maintaining A the operating and safety D EDM characteristics of the series, allows control of forcibly guided NC K contacts of contactors or relays controlled by K the safety outputs of the switch itself. As an alternative to the relays or contactors you can use Pizzato Elettrica expansion modules CS ME0. See page. This check is carried out via the EDM input (External Device Monitoring as defined in EN 9 ) of the switch. VN F VN F VN F K D D D This version, with the IS safety inputs, can be used at the end of a series of switches, up to a maximum number of devices, while maintaining the maximum PL e safety level and acc. to EN ISO 89 and SIL safety level acc. to EN 0. This solution allows you to dispense with the safety module connected to the last device in the chain. K EDM PLC Legend = off = on = flashing = alternating s = indifferent (a) Available only in versions D General Catalogue Safety 0708

9 series safety switches with solenoid and RFID technology Connection with safety modules Connections with CS AR08 safety modules Input configuration with monitored start channels / Category / up to SIL / PL e Connections with CS AR0 / CS AR0 safety modules Input configuration per manual start (CS AR0 ) or monitored start (CS AR0 ) channels / Category / up to SIL / PL e A A S S S S S CS CS S S S S A S S S A Connections with CS AT0 / CS AT safety modules Input configuration with monitored start channels / Category / up to SIL / PL e Connections with CS MF, CS MP safety modules The connections vary according to the program of the module Category / up to SIL / PL e A A A S S S CS Ixx Ixx Ixx Ixx S S S S A CS Application example on page. Pin assignments (version with standard cover D A) Internal terminal strip M connector pole M connector, pole M connector, 8pole standalone connection M connector, 8pole series connection with Y connectors Connection A B I I B I A Supply input 0 V B 0 V auxiliary supply output 8 8 I Solenoid activation input / Signalling output, actuator inserted 9 9 (c) Signalling output, actuator inserted and locked (b) 8 8 / I programming input Supply input Vdc B Auxiliary supply output Vdc, (I th 8 A max.) / Safety input / Safety input / / I EDM input (a) Safety output Safety output 9 7 Important terminals 7, 8, 9, 7, 8 of the internal terminal strip must not 7 8 be used. (a) Available in D version only. 7 (b) For D the output signals the fault condition of the device. (c) Available for 8pole connector, not available for the end of a chain with Y connectors. 8 8 Female connectors see page 99 General Catalogue Safety 0708

10 Dimensional drawings All values in the drawings are in mm Switch DD A Operating principle D, with sealable auxiliary release device, without actuator Switch DE A Operating principle E, without actuator Switch DD A Operating principle D, with key release, without actuator Switch DD A Operating principle D, with key release and emergency release button, without actuator Switch D7D A Operating principle D, with emergency release button, without actuator Switch D7E A Operating principle E, with emergency release button, without actuator Ø 8 Ø Ø 8 Ø Ø 8 Ø VN F. 9. Ø R >0. 8. The D and D files are available at General Catalogue Safety 0708

11 series safety switches with solenoid and RFID technology Switch with integrated fieldwireable control devices D C D D Terminals Terminals NONC NONC 0 emergency button, not illuminated, with rotary release NC button, not illuminated, NONC NONC 0 yellow 7 9 emergency button, not illuminated, with rotary release NC red 8 D E black 7 9 red 8 D F Terminals Terminals NONC NONC green button, not illuminated, NONC 0 NONC black 0 red D G D H Terminals Terminals NONC green NONC 0 0 Terminal assignments (version with integrated control devices) Terminal no. Internal terminal strip for switch D C D D Connection A B I I B I Supply input 0 V 0 V auxiliary supply output Solenoid activation input Signalling output, actuator inserted Signalling output, actuator inserted and locked (b) programming input Supply input Vdc Auxiliary supply output Vdc, (Ith 8 A max.) Safety input Safety input EDM input (a) Safety output Safety output Important terminals 7, 8, 9, 7, 8 of the internal terminal strip must not be used. (a) Available in D version only. (b) For D the output signals the fault condition of the device. Internal terminal strip integrated control devices Supply input Vdc / device Supply input Vdc / device Supply input Vdc / device Supply input 0 V / Contact Device Contact Contact Device Contact Contact Device Contact D E D F D G D H A A A B B B I I I I I I B B B I I I General Catalogue Safety 0708

12 Switch with integrated control devices and M connector, pole D CK0 D DK0 Pin no. Pin no. 7 8 NO NO 7 8 button, not illuminated, NO NO yellow emergency button, not illuminated, with rotary release NC emergency button, not illuminated, with rotary release NC red D EK0 black red D FK0 Pin no. Pin no NO NO green button, not illuminated, NO NO black red D GK0 D HK0 Pin no. Pin no. 7 8 NO green 7 8 NO Terminal assignments (version with integrated control devices) M connector, pole D CK0 D DK0 Connection A B I 9 7 I B I Supply input 0 V 0 V auxiliary supply output Solenoid activation input Signalling output, actuator inserted Signalling output, actuator inserted and locked (b) programming input Supply input Vdc Auxiliary supply output Vdc, (Ith 8 A max.) Safety input Safety input EDM input (a) Safety output Safety output Important terminals 7, 8, 9, 7, 8 of the internal terminal strip must not be used. (a) Available in D version only (b) For D the output signals the fault condition of the device. 7 / / / / 8 / D EK0 D FK0 D GK0 D HK0 A A A B B B I I I I 7 I 7 I 7 B B B I I I Contact Device Contact Contact Device Contact Contact Device Contact Supply input Vdc / device Supply input Vdc / device Supply input Vdc / device Supply input 0 V / Female connectors see page 99 General Catalogue Safety 0708

13 series safety switches with solenoid and RFID technology Dimensional drawings All values in the drawings are in mm Available integrated devices D switch with integrated control devices Colours Article Illuminated button, White Red Green Yellow Blue VN AC00 VN AC00 VN AC00 VN AC00 VN AC00 Combinable with contacts NO NO NONC Installation height (x) mm Ø x Button, not illuminated, springreturn Black VN AC007 NO NO NONC.. Indicator light White Red Green VN AC0 VN AC00 VN AC0 / x Emergency button acc. to. EN ISO 80 Rotary release Pushpull release Emergency release button, illuminated, acc. to. EN ISO 80 Red Red VN AC0 VN AC0 NC. NC. Rotary release Pushpull release Red Red VN AC0 VN AC0 Illuminated selector switch with handle, with transparent lens for Black VN AC0 NO NO NONC.8 Black VN AC0 Key selector switch, positions Black Black VN AC0 VN AC0 NO NO NONC without key ~ with key ~ Closing cap Black VN AC090 / Fixing key Black VN AC080 / / Technical data of the integrated control devices General data Protection degree IP acc. to EN 09 Mechanical endurance Springreturn button million operating cycles Emergency button 0,000 operating cycles Selector switch Key selector switch 0,000 operating cycles 0,000 operating cycles,000 operating cycles including removal of the key Actuating force Springreturn button N min 0 N max. Emergency button 0 N min 0 N max. Selector switch 0. Nm min. Nm max. Key selector switch 0. Nm min. Nm max. Contact blocks of the control devices Material of the contacts silver contacts Contact type Selfcleaning contacts with double interruption Legend Maintained Springreturn Key extraction position Other devices and contacts on request. Please contact our technical office for the complete list of available products. Electrical data Thermal current I th A Rated insulation voltage U i Vac/dc Rated impulse withstand voltage U imp. kv supply voltage Vdc ± % supply current ma per Utilization category of the contact block Direct current DC U e (V) I e (A) 0. In compliance with standards IEC 097, IEC 097, EN ISO 80 Installation for safety applications Always connect the safety circuit to the NC contacts (normally closed contacts) as stated in standard EN 097. General Catalogue Safety 0708

14 Extensions for release button VN ERB Red metal release button Ø M 0 Ø M M M Ø 0 0 M Ø Metal extension for relevn LP0 ase button. For max. wall thickness of 0 mm Metal extensions can be combined with one another to achieve the desired length. Do not exceed an overall length of 00 mm between the release button and the switch. Use mediumstrength thread locker to secure the extensions. 0 M Metal extension for relevn LP0 ase button. For max. wall thickness of 0 mm M M Metal extension for relevn LP ase button. For max. wall thickness of mm Drawing M Metal extension for relevn LP ase button. For max. wall thickness of mm 8 Article.8 9 Compatibility with P KUBE safety handles Anywhere it is necessary to monitor access to dangerous areas of machines or systems, the P KUBE safety handles can be used on doors or guards. Together with the series RFID safety switches with guard locking, these door handles form an integrated locking system for guards that enables access control to dangerous areas. This combination allows a robust system to be created completely out of metal which is compact and configurable. It contains an RFID safety switch with centring pin for the door and optional emergency release button, an adjustable handle with LOCK OUT device and command devices. The same article can be used on hinged doors with left and right stop as well as with sliding doors. Article Safety door handle with LOCK OUT device, with AP GAP plates with multiple fastening options Article Adhesive labels for emergency release button Polycarbonate yellow adhesive, rectangular, 0x mm, red inscription. It has to be fixed on the internal part of the jamb and helps finding the emergency release button. Article Article Safety door handle with LOCK OUT device, with AP GA0P plates with multiple fastening options VF APAGR0 PREMERE PER USCIRE VF APAGR0 PUSH TO EXIT Safety door handle with AP GZ00P LOCK OUT device, with plate Accessories Article VF KLB0 Set of two locking keys Extra copy of the locking keys to be purchased if further keys are needed (standard supply units). The keys of all switches have the same code. Other codes on request. VF APAGR0 ZUM ÖFFNEN DRÜCKEN VF APAGR0 POUSSER POUR SORTIR VF APAGR0 PULSAR PARA SALIR VF APAGR07 НАЖАТЬ ДЛЯ ВЫХОДА VF APAGR08 NACISNĄĆ ABY WYJŚĆ VF APAGR09 PRESSIONAR PARA SAIR Series connection I To simplify series connections of the devices, various M connectors are available that allow complete wiring. This solution significantly reduces installation A times while at the same time maintaining the maximum safety levels PL e and SIL. For further information see page. Items with code on green background are stock items General Catalogue Safety 0708

NG series safety switches with solenoid and RFID technology

NG series safety switches with solenoid and RFID technology series safety switches with solenoid and RFID technology Description These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off,

More information

RFID Safety switch with solenoid NG series

RFID Safety switch with solenoid NG series RFID Safety switch with solenoid series series safety switches with solenoid and RFID technology These switches are used on machines where the hazardous conditions remain for a while, even after the machines

More information

NG Series RFID safety switches with block

NG Series RFID safety switches with block Series RFID safety switches with block Description Series RFID safety switches with block These switches are used on machines where the hazardous conditions remain for a while, even after the machines

More information

ST series safety sensors with RFID technology

ST series safety sensors with RFID technology series safety sensors with RFID technology Introduction In combination with the corresponding safety modules, the sensors of the series are suitable for the monitoring of protective devices on machines

More information

SR A series coded magnetic safety sensor

SR A series coded magnetic safety sensor SR A series coded magnetic safety sensor Selection diagram CONTACTS 0 +NO NC+NO Contact states are displayed for closed guard ACTUATOR SENSOR SM A0N Actuation distance 5 mm OUTPUT TYPE SR AD N PVC cable

More information

SR B series coded magnetic safety sensors

SR B series coded magnetic safety sensors SR B series coded magnetic safety sensors Selection diagram CONTACTS 0 NC NC+NO NC+NO Contact states are displayed for closed guard SENSOR ACTUATOR OUTPUT TYPE SM B0F Actuation distance mm SM B0F Actuation

More information

ST series safety sensors with RFID technology

ST series safety sensors with RFID technology series safety sensors with RFID technology series safety sensors with RFID technology Introduction In combination with the corresponding safety modules, the sensors of the series are suitable for the monitoring

More information

Safety coded magnetic sensor SR A series

Safety coded magnetic sensor SR A series Safety coded magnetic sensor SR A series Selection diagram CONTACTS 0 +NO NC+NO Contacts imply closed protection ACTUATOR SENSOR SM A0N actuation distance 5 mm OUTPUT TYPE SR AD N integrated PVC cable

More information

Coded magnetic safety sensor SR B series

Coded magnetic safety sensor SR B series Coded magnetic safety sensor SR B series Selection diagram CONTACTS 0 NC NC+NO NC+NO Contacts imply closed protection ACTUATOR SENSOR OUTPUT TYPE SM B0F actuation distance mm SM B0F actuation distance

More information

Safety switches with manual mechanical delay and separate actuator

Safety switches with manual mechanical delay and separate actuator Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS short knob 20 seconds MECHANICAL DELAY C L05 L L20 long

More information

Safety hinge switches HX series

Safety hinge switches HX series Safety hinge switches HX series Description Pizzato Elettrica widens its own range of products with the new HX series of safety hinge switches, where safety and style are melted in one single product.

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap

More information

Safety coded magnetic sensor SR B series

Safety coded magnetic sensor SR B series Safety coded magnetic sensor SR B series Selection diagram 0 NC NC+NO NC+NO Contacts have to be intended with closed protection. CONTACTS ACTUATOR SENSOR SM B0F actuation distance mm SM B0F actuation distance

More information

Safety coded magnetic sensor SR A series

Safety coded magnetic sensor SR A series B Safety coded magnetic sensor SR A series Selection diagram ACTUATOR SENSOR CONTACTS SM A0N actuation distance 5 mm 0 +NO NC+NO Contacts have to be intended with closed protection. OUTPUT TYPE SR AD N

More information

Safety switches with manual mechanical delay and separate actuator

Safety switches with manual mechanical delay and separate actuator D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.

More information

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic

More information

Safety hinge switches HX series

Safety hinge switches HX series Safety hinge switches HX series Application field Pizzato Elettrica widens its own range of products making a new series of safety switches hinge-shaped HX series, where safety and style are melted in

More information

Safety coded magnetic sensor SR B series

Safety coded magnetic sensor SR B series B Safety coded magnetic sensor SR B series Selection diagram 0 +NO NC+NO Contacts have to be intended with closed protection. CONTACTS ACTUATOR SENSOR SM B0F actuation distance mm SM B0F actuation distance

More information

Safety switches with separate actuator

Safety switches with separate actuator 4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information

Hinged-shaped safety switches in stainless steel, HX series

Hinged-shaped safety switches in stainless steel, HX series Hinged-shaped safety switches in stainless steel, HX series , HX series Application field Pizzato Elettrica widens its own range of products making a new series of safety switches hinge-shaped HX series,

More information

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

HP-HC series safety hinge switches

HP-HC series safety hinge switches HP-HC series safety hinge switches escription Pizzato Elettrica extends its range of products by creating the new HP-HC series safety hinge switches where safety and style blend into a single product.

More information

Joystick E2 MA series

Joystick E2 MA series E2 MA series Selection diagram CENTRAL LOCK Z Without lock A Lock in all directions HEIGHT 1 2 Standard (55 mm) Reduced (45 mm) ACTUATION FIXING RING 4B 2F 2B 4A 2E 2A LEFT UP LEFT spring-return spring-return

More information

VF CNM5MM-L100. Accessories. M12 male connectors. Code structure. M 12x1

VF CNM5MM-L100. Accessories. M12 male connectors. Code structure. M 12x1 Accessories M male connectors These standard M male connectors are ready for the installation on the switches. Their wires have the right length for the connection to the contact blocks and are provided

More information

Safety hinge switches HP-HC series

Safety hinge switches HP-HC series Safety hinge switches HP-HC series Description Pizzato Elettrica widens its own range of products with the new HP-HC series of safety hinge switches, where safety and style are melted in one single product.

More information

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing Product data sheet Characteristics XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing Main Range of product Product or component type Component name Preventa Safety detection Preventa

More information

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation

More information

Hinged safety switches, Palladio line

Hinged safety switches, Palladio line Hinged safety switches, Palladio line Selection diagram CONTACT BLOCKS 0C 0F 0M C F M snap action snap action snap action C F M CABLE AND CONNECTORS S A P KSM KAM Cable output Cable output M connector

More information

Single buttons. Selection diagram. 31 General Catalogue HMI BUTTON. illuminated button TYPE. R S P F flush projecting protected mushroom

Single buttons. Selection diagram. 31 General Catalogue HMI BUTTON. illuminated button TYPE. R S P F flush projecting protected mushroom Single buttons Selection diagram BUTTON TYPE PU button PL illuminated button R S P F flush projecting protected mushroom BUTTON DESIGN BUTTON COLOUR 2 3 4 5 yellow FIXING RING 6 8 1 blue orange 1 3 Plastic

More information

Datasheet - AZM300Z-ST-1P2P-A

Datasheet - AZM300Z-ST-1P2P-A 08.04.2015-16:04:56h Datasheet - AZM300Z-ST-1P2P-A Solenoid interlock / AZM300 Suitable for mounting to profile systems Thermoplastic enclosure 3 different directions of actuation Compact design 3 LEDs

More information

illuminated button R S P F flush projecting protected mushroom white red green yellow blue orange black

illuminated button R S P F flush projecting protected mushroom white red green yellow blue orange black Single buttons Selection diagram BUTTON TYPE PU button PL illuminated button R S P F flush projecting protected mushroom BUTTON DESIGN BUTTON COLOUR 2 3 4 5 yellow FIXING RING 6 8 1 blue orange 1 3 plastic

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF7 VF KEYF8 CTUTORS HED TYPE ND WORKING PRINCIPLE 96D 96E 98D locked actuator with energized locked

More information

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

Datasheet - AZM 200SK-T-1P2PW

Datasheet - AZM 200SK-T-1P2PW 08.04.2015-16:16:26h Datasheet - AZM 200SK-T-1P2PW Solenoid interlock / AZM 200 thermoplastic enclosure Guard locking monitored Electronic contact-free, coded system Max. length of the sensor chain 200

More information

Datasheet - RSS 36-D-R-ST

Datasheet - RSS 36-D-R-ST 14.03.2018-19:30:37h Datasheet - RSS 36-D-R-ST Safety sensors / RSS 36 Thermoplastic enclosure RFID-technology for needs-based protection against tampering Misaligned actuation possible 27 mm x 108.2 mm

More information

Safety. Detection. Control. MAGNUS RFID ENG - REV

Safety. Detection. Control. MAGNUS RFID ENG - REV 03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide

More information

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016 Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6

More information

Safe timer relay/contact expansion modules

Safe timer relay/contact expansion modules Contact expander module for increasing the number of available contacts, Pulse-on timer relay for step-by-step control of movement sequences, Delay-on energisation timer for unlocking an interlock with

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 10 11 18 19 0 04 05 Ø 8 mm Ø 1,7 mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 31 51 5 57 35 56 41 4 adjustable

More information

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE

More information

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet - MZM 100 B ST-1P2PW2REM-A 19.07.2016-15:57:28h Datasheet - MZM 100 B ST-1P2PW2REM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Safety Switches CES-AR/CET-AR

Safety Switches CES-AR/CET-AR CES-A-L XXXXXX Safety Switches Component overview for non-contact safety switches Connection cable Safety switch Actuator Bolt CES-A-BBA Page 1 CES-A-BCA Page 1 Page 10 CES-AR-C01-... Page 10 CES-A-BPA

More information

Transponder-coded. with guard locking

Transponder-coded. with guard locking Transponder-coded safety switch CTP with guard locking The safety switch CTP The new safety switch CTP combines the proven principle of operation of electromechanical safety switches with guard locking

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Two-hand control unit for press controllers and safety circuits Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous 1

More information

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016 Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions

More information

SAFETY LOCKING DEVICES

SAFETY LOCKING DEVICES L200 Heavy-Duty L200 Safety Locking Device on a very large gate in a logistics operation with forklift traffic The L200 Safety Locking Device designed for highly demanding applications is predestined for

More information

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R 13.06.2016 05:27:33h Datasheet AZM 161SK 12/12RI 024 B6R Solenoid interlock / AZM 161I / AZM 161I B6R right hand model Compact design Interlock with protection against incorrect locking. For very smal

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 0 04 05 Ø 8 mm Ø 1, mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 51 5 5 5 56 41 4 adjustable lever

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet - MZM 100 B ST2-1P2PW2RE-A 19.03.2014-11:42:51h Datasheet - MZM 100 B ST2-1P2PW2RE-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Single contact blocks

Single contact blocks Single contact blocks Selection diagram CONTACT BLOCKS 10G 01G 10L 01K 1NO leading slow slow 1NO slow lagging slow CONNECTIONS silver contacts (standard) G silver contacts gold plated FIXING V clamping

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

Safe switching and monitoring Non-Contact Safety Sensors

Safe switching and monitoring Non-Contact Safety Sensors Safe switching and monitoring Non-Contact Safety Sensors Electronic safety sensors are used to detect guard door closure. These sensors use noncontact operating principles (pulse echo or RFID) that limits

More information

Non-Contact Safety System CES-AZ

Non-Contact Safety System CES-AZ Read head CET-AX-... Read head with guard locking and guard lock monitoring Up to category High locking forces up to 00 N Integrated transponder coding Metal housing Design and functionality With the read

More information

Coded Non-Contact Safety Sensor Eden OSSD

Coded Non-Contact Safety Sensor Eden OSSD Coded Non-Contact Safety Sensor Eden OSSD Approvals: Application: Door and hatches Position control Sector detection Features: Non-contact detection, 0-15 mm OSSD outputs and inputs for serial connection

More information

LED unit. Selection diagram LED COLOUR white LED red LED green LED blue LED orange LED INDICATION MODE CONNECTIONS MOUNTING TYPE

LED unit. Selection diagram LED COLOUR white LED red LED green LED blue LED orange LED INDICATION MODE CONNECTIONS MOUNTING TYPE unit Selection diagram COLOUR 2 3 4 6 8 INDICATION MODE A continuous light L blinking light CONNECTIONS MOUNTING TYPE V clamping screws S solder connection P panel F housing bottom 85 Code structure Attention!

More information

E-STOP relay, safety gate monitor

E-STOP relay, safety gate monitor Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection

More information

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs Flexible Safety Unit / Safety Guard Switching Unit G9SX/G9SX-GS CSM_G9SX_G9SX-GS_DS_E_8_1 Logical Function Adds Flexibility to Various Safety Circuits Be sure to read the Safety Precautions on page 45.

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Gertebild Bildunterschrift Two-hand control device for safety circuits Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary

More information

HAND PROTECTION APPLICATIONS

HAND PROTECTION APPLICATIONS safety HAND PROTECTION LIGHT CURTAINS SG4-B HAND SERIES The new series of SAFEasy SG4-B HAND safety light curtains widens the existing SG range, whilst representing an evolution of the SE4-PLUS line, offering

More information

Microswitches MS Series

Microswitches MS Series General purpose microswitches for heavier duty applications High precision snap action mechanism 16A 250V AC resistive rating (I th ) Wide range of actuator styles Screw terminals with self lifting plate

More information

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 301LC/B-24V 27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit

More information

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i SECTION 16 VIPER Safety Relays Type: SCR-i (with added diagnostics) SAFETY RELAY FUNCTION: IDEM s VIPER SCR-i range of Safety Relays have been designed in accordance with EN60204-1 for safety circuits

More information

Two-hand control unit

Two-hand control unit Unit features Safety features Gertebild Bildunterschrift_gertespezifisch Two-hand control device for safety circuits Approvals Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous

More information

Datasheet AZM 161 Z ST1 AS RA

Datasheet AZM 161 Z ST1 AS RA 25.10.2016 10:35:58h Datasheet AZM 161 Z ST1 AS RA AS interface safety at work / Safety switchgear / Solenoid interlock / AZM 161 AS Preferred typ Solenoid interlock Thermoplastic enclosure High holding

More information

Safety Systems Safety Integrated

Safety Systems Safety Integrated 3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored

More information

Versatile Safety Interlock Switch with Guard Door Locking

Versatile Safety Interlock Switch with Guard Door Locking R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until

More information

MSR178DP. Description. Features. Specifications

MSR178DP. Description. Features. Specifications MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications

More information

Online data sheet. i110-e0453 i110 Lock SAFETY LOCKING DEVICES

Online data sheet. i110-e0453 i110 Lock SAFETY LOCKING DEVICES Online data sheet i0-e0453 i0 Lock i0-e0453 i0 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i0-e0453 6051601 The actuator has to be ordered separately. See "Accessories"

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor

More information

Two-hand control unit

Two-hand control unit Unit features Safety features Gertebild ][Bildunterschrift_Zweihand Two-hand control unit for press controllers and safety circuits Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts

More information

Online data sheet. C4C-EB10530A10000 detec SAFETY LIGHT CURTAINS

Online data sheet. C4C-EB10530A10000 detec SAFETY LIGHT CURTAINS Online data sheet C4C-EB10530A10000 detec A B C D E F Ordering information Type Part no. C4C-EB10530A10000 1219563 Included with delivery with every device: 1 system connecting cable with flying leads

More information

Contact expander modules

Contact expander modules Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

Safe timer relay/contact expansion modules

Safe timer relay/contact expansion modules Gertebild Bildunterschrift Contact expander module for increasing the number of available contacts, Pulse-on timer relay for step-by-step control of movement sequences, Delay-on energisation timer for

More information

Datasheet SRB301ST 24V (V.2)

Datasheet SRB301ST 24V (V.2) 26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable

More information

HR1S-AC Safety Relay Modules

HR1S-AC Safety Relay Modules HRS-AC Relay Modules Transistor output provided. Removable terminal block (HRS-AC52P) allows for easy module replacement. Fault diagnosis function with dual safety circuits. Internal relay operations can

More information

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet - AZM 200 BZ ST-T-AS P 11.02.2013-20:17:11h Datasheet - AZM 200 BZ ST-T-AS P AS interface safety at work / Safety switchgear / Solenoid interlock / AZM 200 AS Preferred typ Solenoid interlock Thermoplastic enclosure High holding

More information

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module

Han PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han

More information

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02 PSEN sensor technology Operating Manual- Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal

More information

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay EN 954 SafeC S Safety Relay SafeC S: Narrow construction of only 22.5 mm SafeC S is a sturdy and extremely inexpensive safety relay which impresses with its unusual efficiency and versatility, despite

More information

Safety relays PNOZsigma

Safety relays PNOZsigma Safety relays PNOZsigma Configuration guide, safety relays PNOZsigma Technical catalogue 3.2 November 2008 edition Why does Pilz offer more? Because the integrality of our business activities is what sets

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation

More information

Online data sheet. i15-mm0123 Lock i15 Lock SAFETY LOCKING DEVICES

Online data sheet. i15-mm0123 Lock i15 Lock SAFETY LOCKING DEVICES Online data sheet i15-mm03 Lock i15 Lock i15-mm03 Lock i15 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i15-mm03 Lock 6034024 The actuator has to be ordered separately.

More information

Datasheet - CSS 11-30S-D-M-ST

Datasheet - CSS 11-30S-D-M-ST 12.02.2013-18:42:30h Datasheet - CSS 11-30S-D-M-ST Safety sensors / CSS 30S Preferred typ Stainless steel enclosure Max. 31 sensors can be wired in series. Connector M12, 8-pole Ø M30 High repeat accuracy

More information

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content 1. About this document DE Betriebsanleitung...............Seiten 1 bis 6 Übersetzung der Originalbetriebsanleitung 1.1 Function This operating instructions manual provides all the information you need

More information

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives Technical information Version 208-05 GEL 6505A: Box for top hat rail mounting, IP 20 variant General The PowerDRIVE-Box GEL

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

SAFETY & MESUREMENT SFIN A GER F OT T PR E. TION light CURTAINS EC Y SG4-FINGER SERIES. highlights

SAFETY & MESUREMENT SFIN A GER F OT T PR E. TION light CURTAINS EC Y SG4-FINGER SERIES. highlights SFIN A GER F PR E OT T EC Y TION light CURTAINS SG4-FINGER SERIES The series of SAFEasy TM SG4-B FINGER safety light curtains widens the existing SG range, whilst representing an evolution of the SE4-PLUS

More information

Safety Relays 3TK2845 Multifunction Device

Safety Relays 3TK2845 Multifunction Device Important Information, Table of Contents Product Description 1 Safety Relays 3TK2845 Multifunction Device Functional Information 2 Technical Data 3 Mounting, Wiring, Initial Start-up 4 Manual Applications

More information