1 1. Hardware: Installation of the PCMeasure Movement Sensor (30114) Connect the sensor to a serial or parallel port of the PC using one of the PCMeasure adaptors, or directly to the PCMeasure Ethernet Box. The RJ45 connector allows the sensor to be patched into other rooms. The RJ45 cable can be any length. The power supply to the sensor can be via the connecting cable from the PC (using the USB connector of the serial or parallel adaptor) or from the Ethernet Box. The sensor is ready for operation approx. 30 seconds after it is switched on. During these 30 seconds, the red LED is lit. 2. Software Configuration: Windows Open the menu item "Setup", "Hardware" to configure the software for the Movement Sensor. Select the applicable port: COM1 to COM4 or LPT1 to LPT3. As sensor type, select "potential-free contact switch contact". 3. Software Configuration: Linux Open the configuration file (pcmeasure4linux.cfg) to configure the software for the Movement Sensor. The settings depend on the port that the sensor is connected to. For example, if the COM1 port is used and the sensor is connected to port 2 of the adaptor: com1.2=04 Close and restart the software to activate the changes to the configuration file. 4. Ethernet Box Configuration Select the menu item "Setup", "Sensors" and configure the sensor as a "switch contact". 5. Testing the Sensor The displays on the sensor have the following meanings: Red light permanently lit, or with short interruptions: moving object detected. Red light - flashes regularly: no object, waiting time of 15 seconds is running down. Green light flashes: no object, normal condition. If an object is detected, the display in the PCMeasure software shows "100". If there is no object, the display shows "0". The sensor works passively, using infra-red. It has a range of 6-8 meters. 6. Sending Alerts The PCMeasure System can pass on alarms via s, SNMP traps, Syslog messages or SMS. Refer to the software instructions for details of how to configure the software to send these alerts. The function of the sensor is equivalent to that of a potential-free contact. 7. Maintenance The movement Sensor needs no maintenance. To remove dust, use a method that does not involve moisture, e.g. a dry cloth or vacuum cleaner.

2 PCMeasure Environment Sensor 1 (30106) 1. Install hardware: First step: Connect sensor direct to serial port (COM1-COM4) of your personal computer. Second step: Connect USB connector to a free USB Slot of your PC. This connection is only used to power the sensor, it also works with systems which not support USB Port, like Windows NT4. An option: you can use RJ45 connectors to extend distance between sensor and PC (up to 100 meters) 2. Configuration PCMeasure Software for Windows First click on menu entry Setup Hardware. Choose interface COM1, 2, 3 or 4. (The interface on which is sensor connected.) Make this entrys: Port 1: Sensor: Temperatur - Temperature Port 2: Sensor: Feuchte Humidity Port 3: Sensor: kein Sensor not in use Port 4: Sensor: kein Sensor not in use Please check that entrys for sensorcode are empty! 2. Configuration PCMeasure Software for Linux Sensor must configured in configuration file pcmeasure4linux.cfg At this example sensor is connected to interface COM1 Make this entrys: com1.1=01 com1.2=03 Restart pcmeasure software for Linux to apply this entrys.

3 Installation of the PCMeasure Environment Sensor 3 (30113) 1. Hardware: Connect Sensor to ports 1, 2, 3 or 4 of the PCMeasure Ethernet Box. The RJ45 connector allows the sensor to be patched into the building's network. The cable length can be up to 100 meters. 2. Sensor Configuration Sensors of type are preconfigured in the Ethernet Box by the manufacturer. To change the default settings, open the menu items 'setup' and 'sensors'. The default user name is 'admin'. The default password is 'secret'. Sensors 1 to 4 correspond to the temperature sensors, and sensors 5 to 8 correspond to the humidity sensors, in the combination sensor Configuration of the PCMeasure Software for Windows, and Access via the Network. You can use the PCMeasure Software for Windows to display and further process the data measured by the sensors. To do this, set the data source in the software display to "remote" and enter the IP address of the Ethernet Box. Access the Ethernet Box data by selecting "com1.1" to "com1.4" for ports 1 to 4, and "com2.1" to "com2.4" for ports 5 to 8. Use the same procedure to access the data via the network, e.g. to incorporate the data in scripts.

4 1. Installing the Hardware: Installation of the PCMeasure Ethernet Box Connect the "Ethernet" port of the Box to a 10 or 10/100 Mbit hub or switch. The Ethernet Box supports a speed of 10 Mbit half duplex. It cannot be operated via 100 Mbit-only ports. 2. Connect the sensors which you will use to Ports 1 to 4 of the Box. The maximum distance of the sensors from the box is 100 meters for the temperature sensors, and 300 meters for all other sensors. 3. Connect the power unit supplied with the Box to socket "PWR" and a power supply outlet. (It is possible to use a different power unit. It must supply Volt DC and have a 5.3mm connector, inside positive. The Ethernet Box is protected against false polarity.) 2. Switching on After a few seconds, the green "Status" LED will start to blink. The green LED "Lnk" shows the status of the network connection. The "Act" LED signals network activity. When first switched on, the Box will have the IP Address (Subnet mask , Gateway ). 3. IP Configuration Enter the address in a web browser to access the home page of the Ethernet Box. Note that the PC for initial configuration must be in the same IP network. If necessary, change the PC's address temporarily. Alternatively, you can use the download utility for new firmware to find the Ethernet Box in the network and change the IP address of the Box in the network temporarily. Note that this IP address change will not be permanent! Now set the new IP address for the Box. To do this, select "setup". (User name: "admin"; password: "secret"). In "setup", you can change the IP address. When you change the address, you will initially lose contact with the Box. Wait approximately 5 seconds, then re-establish contact using the new IP address. 4. Configuration of the Sensors The Box is preset by the manufacturer for operation with 4 temperature sensors (30101,30102 or 30110) or 4 combination temperature/humidity sensors (30113). To change the default settings, select "setup" and "sensors". The default user name is "admin"; the default password is "secret". Sensors 1 to 4 correspond to the connectors on the Box. Sensors 5 to 8 are for use with, for example, the humidity sensors in the combination sensors Configuration of the PCMeasure Software for Windows, and Access via the Network You can use the PCMeasure Software for Windows to display and further process the data measured by the sensors. To do this, set the data source in the software display to "remote" and enter the IP address of the Ethernet Box. Access the Ethernet Box data by selecting "com1.1" to "com1.4" for ports 1 to 4, "com2.1" to "com2.4" for ports 5 to 8, and (if you use the expansion panel) "com3.1" to "com3.4" for ports 9 to 12. Use the same procedure to access the data via the network, e.g. to incorporate the data in scripts. 6. Resetting to Manufacturer's Default Settings To reset the configuration to the manufacturer's default settings, press the "reset" switch during switch-on (using an opened paper clip or similar), and keep the switch pressed for approx. 5 seconds. Then disconnect the power supply again for a few seconds, then switch on again. This will return all settings, including IP address and password, to their initial values. 7. Updating the Firmware The current firmware, together with a utility for transferring it into the Ethernet Box, are available at Transfer takes place via the network (as far as possible the same segment) and lasts approximately 30 seconds.

5 1. Installing the Hardware: Installation of the PCMeasure Ethernet Box Connect the "Ethernet" port of the Box to a 10 or 10/100 Mbit hub or switch. The Ethernet Box supports a speed of 10 Mbit half duplex. It cannot be operated via 100 Mbit-only ports. 2. Connect the sensors which you will use to Ports 1 to 4 of the Box. The maximum distance of the sensors from the box is 100 meters for the temperature sensors, and 300 meters for all other sensors. 3. Connect the power unit supplied with the Box to socket "PWR" and a power supply outlet. (It is possible to use a different power unit. It must supply Volt DC and have a 5.3mm connector, inside positive. The Ethernet Box is protected against false polarity.) 2. Switching on After a few seconds, the green "Status" LED will start to blink. The green LED "Lnk" shows the status of the network connection. The "Act" LED signals network activity. When first switched on, the Box will have the IP Address (Subnet mask , Gateway ). 3. IP Configuration Enter the address in a web browser to access the home page of the Ethernet Box. Note that the PC for initial configuration must be in the same IP network. If necessary, change the PC's address temporarily. Alternatively, you can use the download utility for new firmware to find the Ethernet Box in the network and change the IP address of the Box in the network temporarily. Note that this IP address change will not be permanent! Now set the new IP address for the Box. To do this, select "setup". (User name: "admin"; password: "secret"). In "setup", you can change the IP address. When you change the address, you will initially lose contact with the Box. Wait approximately 5 seconds, then re-establish contact using the new IP address. 4. Configuration of the Sensors The Box is preset by the manufacturer for operation with 4 temperature sensors (30101,30102 or 30110) or 4 combination temperature/humidity sensors (30113). To change the default settings, select "setup" and "sensors". The default user name is "admin"; the default password is "secret". Sensors 1 to 4 correspond to the connectors on the Box. Sensors 5 to 8 are for use with, for example, the humidity sensors in the combination sensors Configuration of the PCMeasure Software for Windows, and Access via the Network You can use the PCMeasure Software for Windows to display and further process the data measured by the sensors. To do this, set the data source in the software display to "remote" and enter the IP address of the Ethernet Box. Access the Ethernet Box data by selecting "com1.1" to "com1.4" for ports 1 to 4, "com2.1" to "com2.4" for ports 5 to 8, and (if you use the expansion panel) "com3.1" to "com3.4" for ports 9 to 12. For access to A/D converter channels, use lpt1.1 to lpt1.4 and lpt2.1 to lpt2.4 Use the same procedure to access the data via the network, e.g. to incorporate the data in scripts. 6. Resetting to Manufacturer's Default Settings To reset the configuration to the manufacturer's default settings, press the "reset" switch during switch-on (using an opened paper clip or similar), and keep the switch pressed for approx. 5 seconds. Then disconnect the power supply again for a few seconds, then switch on again. This will return all settings, including IP address and password, to their initial values. 7. Updating the Firmware The current firmware, together with a utility for transferring it into the Ethernet Box, are available at Transfer takes place via the network (as far as possible the same segment) and lasts approximately 30 seconds. Please use only Ethernetbox 2 firmware files, no firmware for Ethernetbox 1!

6 8. Pinout A/D converter channels port pin A/D Converter channel network request color adapter cable o lpt1.1 green 1 5 Ground brown lpt1.2 yellow (only cable 30308) lpt1.3 green 2 5 Ground brown lpt1.4 yellow (only cable 30308) lpt2.1 green 3 5 Ground brown lpt2.2 yellow (only cable 30308) lpt2.3 green 4 5 Ground brown lpt2.4 yellow (only cable 30308) 9. Measure Range and accuracy Each channel is for use with voltage from 0.5 up to +11 Volt against common ground pin. Please note that there are be no potential difference between ground pin from different ports Each channel is calibrated with an reference signal of 10 Volt and 1 Millivolt accuracy. Each input has an resist of around 10 Kiloohm.

7 Installation of the 12-Port Extension for the PCMeasure Ethernet Box 1. Installation of the Hardware: Connect the 12-Port Extension Panel to the Ethernet Box using the patch cable supplied. Make sure that the ports correspond as follows: Ethernet Box Port Panel Port Ports 1 to 12 on the panel are available for connection of PCMeasure System sensors.

8 Installation of the Port Splitter for the PCMeasure Ethernet Box 1. Installation of the Hardware: You can use the Port Splitter on ports 1 to 4 of the Ethernet Box. The ports on the Port Splitter are allocated in the configuration of the Ethernet Box as follows: Ethernet Box Port Port Splitter Port 1 Port Splitter Port Combination Sensor can be connected only to port 1 of the Port Splitter. All other sensors can be connected to either of the two ports.

9 Installation of the PCMeasure Smoke Sensor (30111) 1. Hardware: Connect the Smoke Sensor to the Ethernet Box using the RJ 45 socket. The RJ45 connector allows the sensor to be patched into other rooms. The cable length can be up to 30 meters. If necessary, you can remove the base plate of the sensors and re-attach it with screws. This will enable you to detach the sensor at any time. If you do this, please take into consideration the length of the cable between the base plate and the sensor, or release the cable tie in advance. 2. Software Configuration: Windows Open the menu item "Setup", "Hardware" to configure the software for the Smoke Sensor. Select the applicable port: COM1 to COM4 or LPT1 to LPT3. As sensor type, select "potential-free contact switch contact". As thresholds for "Display", set the four values "0" "0" "90" "110". In "Events", set a "hysteresis" of "0" and a "delay" of "4". Activate notification "normal!high". 3. Software Configuration: Linux Open the configuration file (pcmeasure4linux.cfg) to configure the software for the Smoke Sensor. The settings depend on the port that the sensor is connected to. For example, if the COM1 port is used and the sensor is connected to port 2 of the adaptor: com1.2=04 Close and restart the software to activate the changes to the configuration file. 4. Ethernet Box Configuration Select the menu item "Setup", "Sensors" and configure the sensor as a "smoke sensor". 5. Testing and Operation of the Smoke Sensor During normal operation, the red LED in the test button of the Smoke Sensor flashes at approx. 50 second intervals. The display in the PCMeasure software or on the Ethernet Box shows "0". If the sensor detects smoke, or test gas, an acoustic warning sounds and the white LED on the sensor begins to light up. After approx. 15 seconds, the Display in the PCMeasure software or on the Ethernet Box shows "100". After the cause of the alarm has been removed, the red LED in the test button continues to flash for approx. 10 minutes. You can test the Smoke Sensor with a test gas or cigarette smoke. There is also a test button on the Smoke Sensor. Press the button (firmly!) down to the pressure point and hold it there for approx. 2 seconds: the Smoke Sensor sounds its acoustic warning and the red LED in the test button flashes 10 times at brief intervals. If the button is not pressed correctly down to its pressure point, an alarm may be triggered after a few seconds. The Smoke Sensor is highly sensitive, and movement of dust in the air may also trigger an alarm. 6. Sending Alerts The PCMeasure System can pass on alarms via s, SNMP traps, Syslog messages or SMS. Refer to the software instructions for details of how to configure the software to send these alerts. The function of the Smoke Sensor is equivalent to that of a potential-free contact. 6. Maintenance The Smoke Sensor needs no maintenance. To remove dust, use a method that does not involve moisture, e.g. a dry cloth or vacuum cleaner. We recommend that you test the sensor at regular intervals.

10 Installation of the PCMeasure Water Sensor (30115) 1. Hardware Connect the sensor to a serial or parallel port of the PC using one of the PCMeasure adaptors, or directly to the PCMeasure Ethernet Box. The RJ45 connector allows the sensor to be patched into other rooms. The RJ45 cable can be any length. The power supply to the sensor can be via the connecting cable from the PC (using the USB connector of the serial or parallel adaptor) or from the Ethernet Box. Plug the water probe into the sensor box, and fix it at a suitable point where a rising water level will create a connection between the two contacts. 2. Software Configuration: Windows Open the menu item "Setup", "Hardware" to configure the software for the Water Sensor. Select the applicable port: COM1 to COM4 or LPT1 to LPT3. As sensor type, select "potential-free contact switch contact". 3. Software Configuration: Linux Open the configuration file (pcmeasure4linux.cfg) to configure the software for the Water Sensor. The settings depend on the port that the sensor is connected to. For example, if the COM1 port is used and the sensor is connected to port 2 of the adaptor: com1.2=04 Close and restart the software to activate the changes to the configuration file. 4. Ethernet Box Configuration Select the menu item "Setup", "Sensors" and configure the sensor as a "switch contact. 5. Testing the Sensor When the water probe is dry, the green LED on the sensor casing will light. The display on the PC will show "0". When both the sensor's contacts are in water, the green LED should go off. The display on the PC should show "100". 6. Sending Alerts The PCMeasure System can pass on alarms via s, SNMP traps, Syslog messages or SMS. Refer to the software instructions for details of how to configure the software to send these alerts. The function of the sensor is equivalent to that of a potential-free contact. 7. Maintenance The Sensor needs no maintenance.

Poseidon 4002 MANUAL

Poseidon 4002 MANUAL Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps

More information

VT608 / Switched PDU with 8 outlets

VT608 / Switched PDU with 8 outlets Switched PDU with Monitoring VT608 / Switched PDU with 8 outlets Device is used for load management and allows to switch on/off or reboot up to 8 outlets. It has built-in temperature sensor, can connect

More information

HWg-STE HWg-STE PoE MANUAL

HWg-STE HWg-STE PoE MANUAL HWg-STE HWg-STE PoE MANUAL HWg-STE connections LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors. - Max. distance with 1

More information

VT805 / Monitoring system

VT805 / Monitoring system Environmental Infrastructure monitoring VT805 / Monitoring system Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible

More information

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring Environmental Infrastructure monitoring VT825 / Environmental Monitoring unit The unit is used for IT environmental control in data-centers, remote facilities, offices, industrial facilities & remote shelters.

More information

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more.

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. VT800 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with all VT or SC sensors, it provides a complete environmental,

More information

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring Environmental Infrastructure monitoring ROOM GUARD VT335 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring Environmental Infrastructure monitoring ROOM GUARD VT335 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with

More information

Connector for sensing cable

Connector for sensing cable HWg-WLD MANUAL ETHERNET 10/100 Mbps Status LED Yellow: Power & Mode Green: Link & Activity Connection cable 100 m max POWER input 5V DC supply Use the supplied power adapter SENSOR Connector for sensing

More information

Poseidon MANUAL

Poseidon MANUAL Poseidon2 3266 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied

More information

Poseidon MANUAL

Poseidon MANUAL Poseidon2 4002 MANUAL www.hw-group.com 2 Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested

More information

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1 Instruction Manual Environmental Monitoring Unit with Optional POE Watchdog 15 Series Firmware Version 1 Geist 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistglobal.com

More information

Operation Manual SuperDry Data Logger (SDDL)

Operation Manual SuperDry Data Logger (SDDL) Operation Manual SuperDry Data Logger (SDDL) 1. Description This device has been equipped with custom-programmable logic module, mounted in it s own housing. The respective module serves to measure the

More information

PCE-IMS 1 User Manual IP Monitoring systems IP Switchable Metered PDU s

PCE-IMS 1 User Manual IP Monitoring systems IP Switchable Metered PDU s PCE-IMS 1 IP Monitoring systems IP Switchable Metered PDU s System installation System setting Accessories Monitoring master unit Extension units Sensors SNMP server List of USB-cameras - 02 - Contents

More information

LAN Interface TCW120B

LAN Interface TCW120B LAN Interface TCW120B 1. Short description TCW120 is a multifunctional device for remote monitoring and management. It is an Ethernet based controller, which is designed to work in IP-based networks and

More information

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5 User Manual Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 4 5. Web Interface... 5 6. Specifications... 8 1. Introduction The ServerLink PDU is a network

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...

More information

Heatmiser Netmonitor v3

Heatmiser Netmonitor v3 Heatmiser Netmonitor v3 Technical Set-Up (Firmware Version 3.5 or above) Function Page Number Connecting to your Netmonitor 2 Changing the Netmonitor IP address 4 Accessing the Netmonitor over the Internet

More information

User Manual. Per Port Monitoring Models

User Manual. Per Port Monitoring Models User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port

More information

Monitoring system LN-VT325. Environmental Infrastructure monitoring

Monitoring system LN-VT325. Environmental Infrastructure monitoring Environmental Infrastructure monitoring Monitoring system LN-VT325 Environmental monitoring of small facilities, access control, monitoring of tempertures, smoke, water leakages, voltages and more. Overview

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. Switched XPDU 15A Model User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 10/02/14) Table of Contents Introduction...4 PDU Package...4 Function...4 Interface...4 Installation...5

More information

Table of Contents. The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System.

Table of Contents. The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System. Operation Manual Table of Contents Description: The Botron B92700 OMNIGND is a Multi-Ground Continuous Monitoring Automation System. Directory: Overview Pg. 2 Features Pg. 3 Quick Setup Guide Pg. 3 Settings

More information

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Contents 1 Warnings, Cautions, and Notes Description Features... 1 EnCell Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 1 3 Features... 1 3.1 STANDARD FEATURES... 1 3.2 FRONT PANEL FEATURES... 2 3.2.1 Display... 2 3.2.2 OK LED... 2 3.2.3 FAULT LED...

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE 2000577 Rev B Release Date - September, 2013 INTRODUCTION The RocketLinx ES8508 series features advanced Layer 2 management

More information

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW WebDAQ 316 Internet Enabled Thermocouple Logger Remote Configuration and Monitoring Virtually Unlimited Storage Integrated HW and SW Flexible Triggers, Alarms, Emails, and SMS Texts Built-in Web Server,

More information

Expert Power Control NET 4x DIN

Expert Power Control NET 4x DIN Expert Power Control NET 4x DIN 2009 Gude Analog- & Digitalsysteme GmbH 2009 Gude Analog- & Digitalsysteme GmbH 14.12.2009 Content 3 Table of contents 1 Security Advise 4 2 Description 5 3 Hardware 3.1

More information

Please take serious note of the following warnings:

Please take serious note of the following warnings: TPDIN-SC48-20 MPPT Solar Controller with Passive PoE Switch Wireless Base Stations and Client Devices Surveillance Cameras Remote Control Remote Lighting Off Grid Electronics Congratulations! on your purchase

More information

Esensors. Websensor User Guide. Save trees. Print only when necessary

Esensors. Websensor User Guide. Save trees. Print only when necessary Esensors Websensor User Guide EM32 Le, Xe Websensors SM1 Le, Xe Soil Moisture sensors AQUO Le, Xe Water sensors PM01 Voltage/ Current Sensors IOT Interfaces Save trees. Print only when necessary ii COPY

More information

The securityprobe5e-x60 s rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x60. securityprobe5es-x60

The securityprobe5e-x60 s rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x60. securityprobe5es-x60 v.100.00x securityprobe5se-x60 will monitor the physical environment and alert you of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke, water leakages, power

More information

The securityprobe5es-x20 s software motion detection and a rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x20

The securityprobe5es-x20 s software motion detection and a rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x20 v.100.00x will monitor the physical environment and alert you of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke, water leakages, power outages and much more.

More information

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

B-33. Hardware and Install Manual. (DC 12V / PoE)

B-33. Hardware and Install Manual. (DC 12V / PoE) B-33 Hardware and Install Manual (DC 12V / PoE) Table of Contents Precautions 3 Safety Instructions... 4 Introduction 6 Package Contents... 6 Physical Description... 7 Installation Procedures 9 Step 1:

More information

Delivered the Way Yo u Want

Delivered the Way Yo u Want SENSAPHONE IMS-4000 Infrastructure Monitoring System Mo nito r What Yo u Want Delivered the Way Yo u Want THE SENSAPHONE IMS-4000 MONITORS AND REPORTS THE INFORMATION THAT YOU NEED TO KNOW: Get critical

More information

ZLJ\YP[`7YVIL, :[HUKHYK

ZLJ\YP[`7YVIL, :[HUKHYK :LUZVY *VU[YVS :LUZVY *VU[YVS (JJLZZ *VU[YVS (JJLZZ *VU[YVS ZLJ\YP[`7YVIL, :[HUKHYK ZLJ\YP[`7YVIL, :[HUKHYK Monitor the physical environment and receive alerts of any disturbances, such as unauthorized

More information

CS141 SNMP / WEB / MODBUS MANAGER

CS141 SNMP / WEB / MODBUS MANAGER CS141 SNMP / WEB / MODBUS MANAGER Slot Version External Version 8 1 4 7 3 2 6 7 5 3 2 6 7 5 3 6 2 CS141SC CS141L CS141MINI Description Function 1 COM1 Port Serial Interface to connect an UPS or another

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

Hardware Installation

Hardware Installation LOLM366912 The ipio-8 is a network attached, IP addressed digital input and output device. The ipio-8 can be controlled and monitored with a standard web browser. Multiple ipio-8 devices can communicate

More information

Network Management Card & Modbus/ Jbus

Network Management Card & Modbus/ Jbus www.eaton.com Network Management Card & Modbus/ Jbus Installation manual 2-34003906EN/AD The Network Management Card & Modbus/Jbus is recommended for central UPSs protecting entire networks or for UPS

More information

CHASSIS-1. Form number 7660

CHASSIS-1. Form number 7660 VideoBridge Chassis Unit CHASSIS-1 Quick Installation Guide Form number 7660 Table of Contents 1 2 3 4 5 About this Quick Installation Guide...3 Quick Quick Installation Guide...3 Safety...3 Verifying

More information

WiFi Edition User Guide Model TM-WIFI330. Rev 2.6 for firmware

WiFi Edition User Guide Model TM-WIFI330. Rev 2.6 for firmware WiFi Edition User Guide Model TM-WIFI330 1 Rev 2.6 for firmware7.00 http://www.temperaturealert.com/ 2013 Temperature@lert User Guide Thank you for choosing Temperature@lert to protect your highly valuable

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

sensorprobe2 / sensorprobe8 User Manual

sensorprobe2 / sensorprobe8 User Manual www.akcp.com sensorprobe2 / sensorprobe8 User Manual Help Version updated till firmware 382L Copyright 2007, AKCP Co., Ltd.. 1) Introduction 1. What is sensorprobe? 2. What s the difference between sp2

More information

SecurityHawk SecurityHawk 8-20

SecurityHawk SecurityHawk 8-20 v.100.00x SecurityHawk 8-20 SecurityHawk 8-20 will monitor the physical environment and alert you of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke, water

More information

Full Color Digital Scouting Camera. User s Manual HCO ScoutGuard SG560C

Full Color Digital Scouting Camera. User s Manual HCO ScoutGuard SG560C Full Color Digital Scouting Camera User s Manual HCO ScoutGuard SG560C Content 1 Instruction... 1 1.1 General Description... 1 1.2 Application... 1 1.3 Camera Interface... 2 1.4 Saving Images or Videos...

More information

L2+ 24-Port Gigabit Managed Switch with. Hardware Layer3 IPv4/IPv6 Static Routing GS S8C GS S8CR. Quick Installation Guide

L2+ 24-Port Gigabit Managed Switch with. Hardware Layer3 IPv4/IPv6 Static Routing GS S8C GS S8CR. Quick Installation Guide L2+ 24-Port Gigabit Managed Switch with Hardware Layer3 IPv4/IPv6 Static Routing GS-5220-16S8C GS-5220-16S8CR Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3.

More information

Low Voltage Probe, LVP-1 (#30019)

Low Voltage Probe, LVP-1 (#30019) Low Voltage Probe, LVP-1 (#30019) The Networked Robotics Low Voltage Probe enables the remote data collection of positive DC voltage via standard computer networks. It is useful for real-time data collection

More information

SEI DC-UPS Power Management Package Users Manual

SEI DC-UPS Power Management Package Users Manual SEI DC-UPS Power Management Package Users Manual (301) 694-9601 (800) 765-4734 Fax (301) 694-9608 Email: info@seipower.com www.seipower.com 5115 Pegasus Court Suite Q Frederick, MD 21704 1. Introduction

More information

SmartZone Gateway- Enabled M Series Rack PDU

SmartZone Gateway- Enabled M Series Rack PDU SmartZone Gateway- Enabled M Series Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system,

More information

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer K01-SNMP004-00 TABLE OF CONTENTS INTRODUCTION... 1 INSTALLATION GUIDE...

More information

HVG400. Installation Guide

HVG400. Installation Guide HVG400 Installation Guide September 2013 Trademarks & Copyright Trademarks All trademarks mentioned in this manual are the sole property of their respective manufacturers. Copyright Ltd., Jerusalem, Israel

More information

IP Sensor IPS2222 User manual

IP Sensor IPS2222 User manual IP Sensor IPS2222 User manual Output LED indicators Power input 12VDC adapter 2 Relay outputs LED Indicators 1 wire 2 Dry 2 Analog Green : Power Yellow: Link temperature & humidity contact inputs inputs

More information

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual LOGGER S0541 Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual Instruction Manual for use of S0541 logger Instrument is designed for measurement and record of temperature

More information

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3 KRAMER ELECTRONICS LTD. USER MANUAL MODELS: VA-1USB-T USB Transmitter VA-1USB-R USB Receiver P/N: 2900-300209 Rev 3 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2

More information

DMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE

DMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE DMC-1002 SNMP Module for Chassis-Based Media Converter Manual Rev. 01 (JUN. 2002) 1907MCB10016000 RECYCLABLE TABLE OF CONTENTS ABOUT THIS GUIDE... 2 FEATURES...2 UNPACKING...2 CONFIGURING THE SYSTEM...

More information

Technical Overview CM-5 The Compact Climate Monitor Bundle. Get yours direct at:

Technical Overview CM-5 The Compact Climate Monitor Bundle. Get yours direct at: Technical Overview CM-5 The Compact Climate Monitor Bundle Get yours direct at: 01491 410913 www.theclimate.co.uk OVERVIEW Bundling five CM-1 Climate Monitors, the CM-5 is a great solution for multiple

More information

SMART Coin System QUICK START AND CONFIGURATION GUIDE

SMART Coin System QUICK START AND CONFIGURATION GUIDE SMART Coin System QUICK START AND CONFIGURATION GUIDE SMART Coin System Quick Start and Configuration Guide 2 SMART Coin System Quick Start and Configuration Guide 1 INTRODUCTION 4 2 ASSEMBLY 5 2.1 Detaching

More information

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.

More information

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

Communication adapter RS485/422 over the Ethernet ELO E222. User manual Communication adapter RS485/422 over the Ethernet ELO E222 User manual Table Of Content: 1.0 Introduction... 3 1.1 Application... 3 2.0 How does it works?... 4 3.0 Installation... 4 3.1 Ethernet connection...

More information

DPM/DE19B/DEPC User Manual

DPM/DE19B/DEPC User Manual DPM/DE19B/DEPC User Manual Rev. A 010244 2007 Hoffman Enclosures Inc. P/N 87928906 87928905 Description The Hoffman Smart units consist of Power Distribution Units and Environmental Monitors with a built

More information

Humidity Probe, HPL-1 (#30009)

Humidity Probe, HPL-1 (#30009) Humidity Probe, HPL-1 (#30009) The Networked Robotics HPL1 Humidity probe allows the Tempurity System to monitor both temperature and relative humidity over the network. The HPL1 is designed to be used

More information

EP2 EP8 User Manual. Copyright 2007,ATAL

EP2 EP8 User Manual. Copyright 2007,ATAL EP2 EP8 User Manual Copyright 2007,ATAL 1) Introduction 1. What is EP? 2. What s the difference between the EP2 and the EP8? 3. How to use this manual 4. EP2 5. EP8 2) Installation 1. Assigning an IP address

More information

Mini Bass Meter User Manual

Mini Bass Meter User Manual 2016 Mini Bass Meter User Manual Sound pressure meter with voltmeter function SPL-Laboratory 14.05.2016 Table of Contents Table of Contents... 2 Functions and technical features of the device... 3 Description...

More information

Infrared Digital Scouting Camera. User s Manual Scouting Camera SG560P-8M

Infrared Digital Scouting Camera. User s Manual Scouting Camera SG560P-8M Infrared Digital Scouting Camera User s Manual Scouting Camera SG560P-8M Content 1 Instruction...1 1.1 General Description...1 1.2 Application...1 1.3 Camera Interface... 2 1.4 Saving Images or Videos...

More information

ColourChaser Touch. Installation Guide

ColourChaser Touch. Installation Guide ColourChaser Touch Installation Guide Dimensions C I S 110 29 72 Ø 4.5 56 85 I 2 3 4 100 77 ColourChaser Touch - Dimensions in mm Bracket - Dimensions in mm 2 Philips ColourChaser Touch Manual Content

More information

JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required

JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required JNIOR Series 4 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 2.0 NOTE: JANOS OS 1.1 or greater required INTEG Process Group, Inc. 2919 East Hardies Rd, First Floor Gibsonia,

More information

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O

More information

Temperature logger with display Instruction Manual

Temperature logger with display Instruction Manual LOGGER S0110 Temperature logger with display Instruction Manual Instruction manual for use of temperature logger S0110 Logger is designed for measurement and record of temperature from built-in internal

More information

INSTRUCTION MANUAL V1. 2x A

INSTRUCTION MANUAL V1. 2x A INSTRUCTION MANUAL V1. 2x A INTRODUCTION... 3 CONNECTIONS AND INSTALLATION... 4 MECHANICAL INSTALLATION... 4 ATTACHING AND DETACHING THE FRONT COVER... 8 ATTACHING AND DETACHING THE HMI... 9 ELECTRICAL

More information

Network / IP Camera User Manual

Network / IP Camera User Manual Network / IP Camera User Manual Preface Congratulations on your purchase of this product. Read this manual carefully and keep it in a safe place for future reference. About this manual This user manual

More information

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Hardened Web-Smart PoE & High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart PoE (Power over Ethernet) and High Power PoE Ethernet Switch. This is the switch of choice for harsh environments

More information

E600 VX01 Installation guide

E600 VX01 Installation guide E600 VX01 Installation guide illuminfx Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing

More information

Xenon Flash Digital Scouting Camera. User Manual SG565F-14mHD

Xenon Flash Digital Scouting Camera. User Manual SG565F-14mHD Xenon Flash Digital Scouting Camera User Manual SG565F-14mHD Content 1 Instruction... 1 1.1 Camera Body Interfaces... 1 1.2 General Description... 2 1.3 Application... 2 1.4 Shooting Information Display...

More information

DPM-3221 Digital DC Power Meter with data logging capability.

DPM-3221 Digital DC Power Meter with data logging capability. Introduction DPM-3221 Digital DC Power Meter with data logging capability. User Manual As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-200 A with the correct shunt),

More information

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual KIEN2204S Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co., Ltd. Publication Date: Mar. 2013 Version: V1.0 FAX: +86-10-88796678 Website: http://www.kyland.com E-mail: support@kyland.com

More information

epowerswitch 8M+ R2 User guide Version

epowerswitch 8M+ R2 User guide Version epowerswitch 8M+ R2 User guide Version 03 2011 www.neol.com Copyright by NEOL S.A.S - 4 Rue Nationale, 67800 BISCHHEIM, France Printed in France All rights reserved. No part of this documentation, accompanying

More information

Ethernet controller TCW180B Users manual

Ethernet controller TCW180B Users manual Ethernet controller TCW180B Users manual 1. Short description TCW180B is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs. This

More information

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ & BLUEstreak POWER SHELVES

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ & BLUEstreak POWER SHELVES SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ & BLUEstreak POWER SHELVES www.unipowerco.com 2017 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065,

More information

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items: Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this

More information

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

Setting Up Your Cisco Unified Videoconferencing 3515 MCU CHAPTER 2 Setting Up Your Cisco Unified Videoconferencing 3515 MCU This section describes the following topics: Physical Description, page 2-1 Preparing for Installation, page 2-2 Verifying the Package

More information

DATA LOGGER MODELS DL-1080/1081

DATA LOGGER MODELS DL-1080/1081 DATA LOGGER MODELS DL-1080/1081 USER MANUAL V1.5x INTRODUCTION... 4 CONNECTIONS AND INSTALLATION... 5 MECHANICAL INSTALLATION... 5 ATTACHING AND DETACHING THE FRONT COVER... 8 ATTACHING AND DETACHING THE

More information

ZN-7100-DE500-G V ac Wireless Access Point Quick Setup Guide

ZN-7100-DE500-G V ac Wireless Access Point Quick Setup Guide Bottom View ZN-7100-DE500-G V4 802.11ac Wireless Access Point Quick Setup Guide This Quick Setup Guide provides step-bystep instructions on how to set up your ZN- 7100-DE500-G V4 Wireless Access Point.

More information

Infrared Digital Scouting Camera User s Manual Scouting Camera SG560K-8M

Infrared Digital Scouting Camera User s Manual Scouting Camera SG560K-8M Infrared Digital Scouting Camera User s Manual Scouting Camera SG560K-8M For model: SG560K-8M Content 1 Instruction...1 1.1 General Description...1 1.2 Application...1 1.3 Camera Interface...1 1.4 Saving

More information

VIDEO GRABBER. DisplayPort Standard. User Manual

VIDEO GRABBER. DisplayPort Standard. User Manual VIDEO GRABBER DisplayPort Standard User Manual Version Date Description Author 1.0 2016.03.02 New document MM 1.1 2018.03.22 Update document. Add new functionality: monitor emulation, network bridging,

More information

Preface. Managed Media Converter Chassis System

Preface. Managed Media Converter Chassis System Preface The Managed Media Converter Chassis System supports the Media Converter Chassis to monitor the each Media Converter ( CO ) or Chassis Manager status and to configure advanced function of the Managed

More information

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web:   ; User s Manual Management Converter Chassis Model No.: SP1386 / SP1387 World Wide Web: www.micronet.com.tw ; www.micronet.info Table of Content 1. INTRODUCTION... 2 1.1 PACKAGE CONTENT... 2 1.2 KEY FEATURES...

More information

RS485 CO2 sensor etc. all of these functions for smart home are pre-programed

RS485 CO2 sensor etc. all of these functions for smart home are pre-programed Mini USB Micro SD card reader Uploader port Ext. temp sensors Ground loop, After heater, control Compressor control Time delay, bathroom boost RS485 LAN CO2 sensor etc. all of these functions for smart

More information

Medium parts count, through-hole components (with exception of optional surface mount MAC IC).

Medium parts count, through-hole components (with exception of optional surface mount MAC IC). Introduction The E1.31 DMX Bridge is an interface intended to be used as part of a system to operate a lighting display that consists of DMX or Renard controlled dimmers. To form a complete system, the

More information

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL 2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital

More information

Dynamic-UserCenter 32

Dynamic-UserCenter 32 Dynamic-UserCenter 32 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility

More information

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09. Encoder Firmware V4.06.09 User s Manual Outdoor PTZ Camera Hardware Manual KCM-8211 2013/05/09 1 Table of Contents Precautions... 3 Introduction... 4 List of Models... 4 Package Contents... 5 Safety Instructions...

More information

Poseidon 2250 Short Manual

Poseidon 2250 Short Manual Poseidon 2250 Short Manual www.hw-group.com 1 / 54 Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has

More information

Date Revision Change(s) 29/07/ First version

Date Revision Change(s) 29/07/ First version Revision overview Revision overview Date Revision Change(s) 29/07/2016 0 First version Copyright 2016 Indu-Sol GmbH We reserve the right to amend this document without notice. We continuously work on further

More information

Contents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch...

Contents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch... Contents GV-I/O Box 8 Ports...2 1. Key Features... 2 2. Compatible Software... 2 3. Packing List... 2 4. Overview... 3 5. DIP Switch... 3 6. Connections to PC... 4 6.1 Installing USB Driver... 5 6.2 Assigning

More information

VISTA Transfer Station Setup

VISTA Transfer Station Setup Setup Setup The allows your agency to upload video evidence to its WatchGuard Video Evidence Library software from multiple VISTA cameras simultaneously. Each VISTA Transfer Station has eight slots for

More information