TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS
|
|
- Carol Simon
- 5 years ago
- Views:
Transcription
1 TELESERVICE Teleservice with TS Adapter IE Teleservice with TS Adapter II Page 1864 Mar 2008 Siemens ITS
2 For performing remote maintenance over the telephone network: A PG/PC with an Engineering Tool installed, e.g. STEP 7, can access automation components (e.g. S7 CPUs) over the telephone network that are connected to the appropriate adapters over Industrial Ethernet or PROFIBUS. Comprising the TeleService software and different adapters: TS Adapter II for connection to PPI, MPI or PROFIBUS DP TS Adapter IE or TS Adapter IE Basic for connection to Industrial Ethernet Additional functions with TS Adapter II: Establishing a connection from/to remote plants, e.g. for calling up process data from an automation system (PG-to-AS remote coupling). Teleservice with TS Adapter IE Basic Page 1865 Mar 2008 Siemens ITS
3 Exchanging data between plants (AS-to-AS remote coupling): Exchange of process data between two SIMATIC automation systems. Sending a text message: Sending a text message from a SIMATIC automation system via a GSM wireless modem. Additional functions with TS Adapter IE: Remote operation of HMI devices: Access to the HMI device via an Internet browser installed on the adapter Sending s: Establishing a modem link to a dial-up server (e.g. to an Internet service provider): A SIMATIC CPU can send s over an server that can be accessed in this manner. Standard routing: A modem link can be established to an Internet service provider for accessing data on the Internet. Function TeleService is stand-alone software and does not require the installation of other software products such as STEP 7. When using the TIA Portal, the TeleService software is not required because the functions are already a component part of the TIA Portal. The following functions are available for remote maintenance with TeleService: Page 1866 Mar 2008 Siemens ITS
4 Support for the TS Adapter II, TS Adapter IE and TS Adapter IE Basic. Parameterization of the modem: On the PG/PC side, parameterization using Windows tools is supported. On the line side, the TS Adapter (with default settings) performs parameterization. Electronic telephone book: To support the administration of plants (e.g. telephone number, location). Multi-level access protection: Prevents unauthorized connection build-up to a plant by means of a password and/or callback telephone number (callback function). Callback function: The plant calls the service center back automatically following a TeleService call. Routing of the PG functionality: Routing over TeleService is supported in the same manner as for a local connection. S7/M7 CPUs and CP modules with routing capability are required for this purpose. Import/export of the TS Adapter parameters: The parameters can be saved in a file (*.tap) on the PG/PC and reloaded. Authorization via the Automation License Manager. For use with Windows 2000, Windows XP Home and Windows XP Professional. TS Adapter II; TS Adapter IE and TS Adapter IE Basic provide additional functions. TS Adapter II: Establishing a connection from/to remote plants, e.g. for calling up process data from an automation system (PG-to- AS remote coupling). Page 1867 Mar 2008 Siemens ITS
5 Exchange of data between plants (AS-to-AS remote link): Exchange of process data between two SIMATIC automation systems. Sending a text message: Sending a text message from a SIMATIC automation system via a GSM wireless modem. TS Adapter IE: Remote control of HMI devices: The TS Adapter IE in combination with a browser installed on the PG/PC (e.g. Internet Explorer) and the Sm@rtViewer supports access over the telephone network to a SIMATIC HMI device with an installed Runtime option of WinCC flexible /Sm@rtService or /Sm@rtAccess. The HMI device or machine/plant can then be remotely controlled from the PG/PC. Sending s: The function block AS_MAIL (included in the scope of supply of the adapter or TeleService V6.1) can be used to send s directly from a SIMATIC CPU over the TS Adapter IE. The TS Adapter IE builds up an outgoing modem connection to a dial-up server for this purpose, e.g. to an Internet service provider, and sends the s via an server that can be accessed there. If the provider offers the service for converting s to text messages, text messages can also be sent in this manner. Standard routing: The TS Adapter IE allows a modem link to be established to an Internet service provider for accessing data on the Internet over this link. While the link is established, telephone dial-up and therefore remote maintenance and remote control is not possible. Page 1868 Mar 2008 Siemens ITS
6 TS Adapter IE Basic (in conjunction with a TS module): Remote maintenance over the telephone network: The TS Adapter IE Basic enables an application running on the PG/PC, such as STEP 7, to access Industrial Ethernet-connected S7 and C7 automation components over the phone network. For this, the TS Adapter IE Basic requires the following: a connection to the automation components via Industrial Ethernet, and a modem connection to the PG/PC. Sending s: With the AS_MAIL function block, you can send s from a SIMATIC CPU via the TS Adapter IE Basic. To do this, the TS Adapter IE Basic establishes an outgoing modem connection to a dial-up server, such as an Internet Service Provider (ISP), and sends the s via a mail server accessible there. To establish a remote connection through the telephone network you will alternatively need: TIA Portal V11.0 (contains all the necessary TeleService functions), TeleService V6.1 or Windows dial-up network Technical specifications Page 1869 Mar 2008 Siemens ITS
7 TS Adapter II Dimensions (W x H x D) in mm 125 x 110 x g Interfaces to S7/C7 RS 485 (up to 12 Mbit/s) to the PC USB 1.1 (12 Mbit/s) to an external modem RS 232 (up to 115 kbaud) to the analog telephone network RJ12 to the ISDN telephone network RJ45 Supply voltage, external or via MPI interface 24 V DC Current consumption 60 ma (typ.) / 120 ma (max.) Switch-on current, max. 0.7 A; 8 µs Degree of protection IP20 Temperature Operation ±0 C to +60 C Storage/transport -40 C to +70 C TS Adapter IE Dimensions (W x H x D) in mm 125 x 110 x 40 approx. 370 g Interfaces Ethernet RJ45 (10/100 Mbit/s) Page 1870 Mar 2008 Siemens ITS
8 to an external modem RS 232 (up to 115 kbaud) to the analog telephone network RJ12 to the ISDN telephone network RJ45 Supply voltage, external or via MPI interface 24 V DC Current consumption of the TSA-IE ISDN typ. 170 ma / max. 230 ma Current consumption of the modem TSA IE typ. 180 ma / max. 240 ma Switch-on current, max. 0.7 A; 8 µs Degree of protection IP20 Temperature Operation ±0 C to +60 C Storage/transport -40 C to +70 C TS Adapter IE Basic (basic unit) Dimensions (W x H x D) in mm 30 x 100 x g Interfaces Ethernet RJ45 (10/100 Mbit/s) To the TS module Proprietary (can only be used for TS modules) Supply voltage, external 24 V DC Current consumption With TS module modem Typ. 50 ma, max. 80 ma with TS module ISDN Typ. 50 ma, max. 80 ma Page 1871 Mar 2008 Siemens ITS
9 with TS module RS232 with TS module GSM Switch-on current, max. Degree of protection Temperature Operation Typ. 40 ma, max. 60 ma Typ. 100 ma, max. 180 ma 240 ma IP20 Storage 40 C to +70 C ±0 C to +60 C (horizontal installation) ±0 C to +40 C (vertical installation) TS module modemtimes Dimensions (W x H x D) in mm, approximately 30 x 100 x g ITU transmission standards V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34, V.34x, K56flex, V.90, V.92 Other features Error correction and data compression a/b interface Hayes (AT) command set All data formats Dial procedures: dual-tone multiple-frequency (DTMF), pulse dialing TS module ISDN Dimensions (W x H x D) in mm 30 x 100 x g Reports Page 1872 Mar 2008 Siemens ITS
10 D channel protocols B channel protocols Other features DSS1 (Euro-ISDN), 1TR6 V.110 (9600 bit/s, bit/s, bit/s) V.120 (64 Kbit/s) X.75 (64 Kbit/s) Multiple subscriber number (MSN) AT command interpreter TS module RS232 Dimensions (W x H x D) in mm 30 x 100 x g Operating mode Full duplex, asynchronous Signals Data transmission rate Message frame Rule Connector TS module GSM Dimensions (W x H x D) in mm 30 x 100 x 75 Transmission rate GPRS Multislot Class 10 Up to 2 uplinks TXD, RXD, DSR, CTS, RTS, DTR, DCD bit/s 8 data bits (LSB first), no parity bit, 1 stop bit according to RS232 standard D-sub 9-pin, male (PC COMx) 118 g 13.4 Kbit/s 27 Kbit/s upload gross Page 1873 Mar 2008 Siemens ITS
11 Up to 4 downlinks Interfaces SIM interface Antenna connection Frequency ranges Transmitted output power 40 Kbit/s 54 Kbit/s download gross 3 V/1.8 V 1 x SMA antenna socket (50 Ohm) Quad band: 850, 900, 1800, 1900 MHz 2 W at 850 MHz, 900 MHz 1 W at 1800 MHz, 1900 MHz Page 1874 Mar 2008 Siemens ITS
Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522
4.2 ISDN devices 502 506 512 522 532 536 542 552 556 Voltage VDC 24 Current ma (24V) 60 60 70 90 90 100 80 100 110 Protection class (IP) 20 Range of use Dry Surroundings Temperatures (Plant) 0 50 C Temperatures
More informationIE/PB LINK PN IO. PROFINET applications
IE/PB LINK PN IO PROFINET applications Protection of investment due to simple connection of PROFIBUS DP slaves to PROFINET IO controller Enables the use also in plants with PROFIsafe applications Independence
More informationMPI-BUS. Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter
MPI-BUS Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter 70 MPI-Bus Catalog 11 SSW7, MPI-Programming Adapter Features Programming and visualization up to 115 kbaud MPI up to 187,5 kbps Power
More informationThe TRSUN is the complete solution for the remote monitoring of photovoltaic plants.
The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system
More informationWhy can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014
FAQ 03/2014 Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - http://support.automation.siemens.com/ww/view/en/88633853 This entry is from the Siemens Industry Online
More informationThe modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface
DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,
More informationTIM 3V- IE ADVANCED. Function
TIM 3V- IE ADVANCED Function The TIM 3V-IE Advanced enables one or more SIMATIC S7-300 or control center PCs (e.g. SINAUT ST7cc or ST7sc) to exchange data with other SINAUT ST7 or ST1 stations via any
More informationNETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways
NETL ink gateways Ethernet gateways WLAN gateways High-speed USB gateways ETHERNET NETL ink PRO PoE, PROFIBUS Ethernet gateway FEATURES RFC (ISO on TCP) CPU-to-CPU communication (with S-¹ and S-¹) (POE)
More informationGNS-MC35iT, GNS-MC35iU Terminals datasheet
datasheet 2007 Contents Document history...3 1 Abstracts...4 2 Key features...4 3 Electrical and environmental characteristics...5 4 Operating modes...7 5 Power supply...8 6 Power on/off control...9 7
More informationA TECHNICAL INFO A. External GSM AT420 DATE :
DATE :02-02-04 A TECHNICAL INFO A External GSM AT420 The external GSM AT420 is a GSM data modem. It allows a communication with the A when a cabled telephone connection is impossible. This modem can be
More informationS2C Link Accessory Kit Datasheet
S2C Link Accessory Kit Datasheet Part Number: NL-S2CK NimbeLink Corp Updated: May 2018 PN 30230 rev 3 NimbeLink Corp. All Rights Reserved 1 Table of Contents Introduction 3 Overview 3 Technical Specifications
More informationAccessories / 7XV5820
Accessories / XV0 XV0 industrial modem and modem-router with switch LSP.tif LSP.tif LSP.tif Modem k / ISDN TA Modem /ISDN Router Pocket Modem / ISDN Fig. / Industrial modems Depending on the available
More informationChamber of commerce: Het Kasteel 315. All our proposals and agreements are subject to the General conditions of
GSM-to-Serial bridge Overview The GSM-to-Serial (short: G2S) bridge is a ready-to-use protocol converter that is intended for extending the communications reach of an existing device with an ethernet interface
More informationSINAUT ST7 station control system SIMATIC NET. Industrial Remote Communication - TeleControl SINAUT ST7 station control system.
Preface Properties of the SINAUT components 1 SIMATIC NET Industrial Remote Communication - TeleControl System Manual Network structures and topologies 2 Installation guide 3 Installing and putting a TIM
More informationSSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21
SSW7 Adapter for MPI-Bus 700-751-1VK21 User Manual Version:2 / 2009-03-20 HW: 1 / FW: 3.0 and higher Order number of manual: 700-751-1VK21/en Systeme Helmholz GmbH Hannberger Weg 2 D-91091 Großenseebach
More informationV2400 Series Expansion Modules
Rolling Stock Computers V2400 Series Expansion Modules Expansion peripheral modules (EPM) for the V2400 series PCI slots for interface expansion EPM-3032: 2 isolated RS-232/422/485 ports with DB9 connectors
More informationZETA Series 2G/3G/4G Modems with GPS Option
Key Features 2G/3G/4G versions AT command driven Industrial grade RoHS compliant Extended temperature range Extended RF sensitivity Embedded TCP / IP stack 5-42V DC supply 4 x GPIO ADC Additional Features
More informationParameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:
CPU 315-2 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the
More informationZETA Series 2G/3G/4G Modems with GPS Option
Key Features 2G/3G/4G versions AT command driven Industrial grade RoHS compliant Extended temperature range Extended RF sensitivity Embedded TCP / IP stack 5-42V DC supply 5 x GPIO 1 x ADC Additional Features
More informationApplication. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
More informationCPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS
CPU 319F-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 100 error and interrupt events are stored in a buffer
More informationMPCIE-3G Quick Installation Guide
PCI Express Mini 3G Adapter Card, RoHs MPCIE-3G Quick Installation Guide Version 1.0 Jul 01, 2014 Package Contents: MPCIE-3G package includes the following items: 1 x MPCIE-3G PCI Express Mini 3G adapter
More informationCPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS
CPU 317F-2 DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 100 errors and interrupt events are saved in a buffer for
More informationTELTONIKA ModemCOM (TMC-10x) User Manual V
TELTONIKA ModemCOM (TMC-10x) User Manual V2.1.1.18 TABLE OF CONTENTS ATTENTION!...3 LEGAL NOTICE...3 INTRODUCTION...4 1. PACKAGE CONTENTS...5 2. TECHNICAL SPECIFICATIONS...6 2.1. Data transferring...6
More informationApplication. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Data Sheet Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks.
More informationInstallation and Configuration Quick Guide GoRugged M1000 MP
Installation and Configuration Quick Guide GoRugged M1000 MP Industrial Cellular Modem 1 RS-232/RS-485 + 1 USB Host Package Contents Before installing your M1000 MP Modem, verify the kit contents as following.
More informationSIMATIC. TeleService V6.0 Service Software for SIMATIC S7 and C7. Preface, Contents. TeleService Introduces Itself. Installing Software and Hardware 2
s SIMATIC TeleService V6.0 Service Software for SIMATIC S7 and C7 Manual Preface, Contents TeleService Introduces Itself 1 Installing Software and Hardware 2 Basics of TeleService 3 Setting Parameters
More informationSelect a Data Communication Interface
Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The
More informationPA ROUTERS. The following criteria can be applied when choosing the network transition:
PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied
More informationirz MC55iT GPRS class 10 GSM modem USER MANUAL
irz MC55iT GPRS class 10 GSM modem USER MANUAL Contents 1. Safety Requirements... 3 2. General Information...4 2.1. Purpose of the Device...4 3.1. Configuration...4 3.2. Parameters...4 3.3. Exterior Appearance...6
More informationG3x Series. Technical Product Description. Fixed Wireless Terminals for GSM/EDGE Mobile Networks
221 02-FGB 101 350 Uen Rev C Fixed Wireless Terminals for GSM/EDGE Mobile Networks Technical Product Description The product description for the Fixed Wireless Access Terminals offers a complete description
More informationTechnical data. General features of the DVIVision series. English. Video: Interfaces to computer. Audio:
General features of the DVIVision series DVIVISION SERIES computer remote console PS/2 keyboard/mouse: USB keyboard/mouse: variants -AR and-aru USB 1.1: variants -ARU and -U variants -AR and -ARU PS/2
More informationTechnical Manual for RTCU M10 / M10G
Technical Manual for RTCU M10 / M10G Version 1.04 Introduction This manual contains technical documentation allowing easy installation and use of the RTCU M10 / M10G unit. In the following text RTCU M10
More informationData sheet VIPA CPU 214PG (214-2BE03)
Data sheet VIPA CPU 214PG (214-2BE03) Technical data Order. General information Note - 214-2BE03 VIPA CPU 214PG Features Work memory [KB]: 96 Interface [RJ45]: Ethernet PG/OP communication Interface [RS485]:
More informationSupply voltage. Input current. Encoder supply. Memory
Data sheet SIMATIC S7-200, CPU 224XP COMPACT UNIT, DC POWER SUPPLY 14 DI DC/10 DO DC, 2 AI, 1 AO 12/16 KB CODE/10 KB DATA, 2 PPI/FREEPORT PORTS Supply voltage Rated value (DC) 24 V DC Load voltage L+ Rated
More informationOnCell G3100 Series Quick Installation Guide
OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationData sheet VIPA CPU 214NET PG (214-2BT13)
Data sheet VIPA CPU 214NET PG (214-2BT13) Technical data Order. 214-2BT13 VIPA CPU 214NET PG General information Note - Features Work memory [KB]: 96 Integrated Ethernet CP 243 Interface [RJ45]: active
More informationSitePORTAL Lite TA-SPL32-R48
SitePORTAL Lite TA-SPL32-R48 Quick Connect Guide The TA-SPL32-R48 is a 19 inch, 2 RU rack mountable siteportal Lite (spl). It comes with 8 analog inputs, 8 temperature inputs (sensors sold separately),
More informationPAS 300, PROFIBUS Slave Interface Module
Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz
More informationTechnical data. General features of the series. English. Video: Interfaces for computers. 3.5-mm jack plug (Line Out) USB 2.
Technical data General features of the series DP1.2-VISION-CAT SERIES computers PS/2 keyboard: USB keyboard/mouse: Audio: : RS232: PS/2 keyboard/mouse: USB keyboard/mouse: Generic-HID: Audio: : Variant
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300 CPU319F-3 PN/DP, CENTRAL PROCESSING UNIT WITH 2.5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, 3. INTERFACE ETHERNET PROFINET, WITH 2 PORT
More informationSIPLUS CPU 313C-2DP. Function
SIPLUS CPU 313C-2DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in
More informationEZ864 UMTS Terminal Telit Cellular GSM Engine
EZ864 UMTS Terminal Telit Cellular GSM Engine Version: 01.01 EZ864 UMTS Terminal_HD_V01.01 06.Mar.2008-1 - Hardware Interface Description 1. Hardware Features of the EZ864 UMTS Terminal Feature Implementation
More informationBluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual
Bluetooth to RS-232&RS422/485 EX-9132B/BI Bluetooth Adapter Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel
More informationGeneral information. Supply voltage
Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1
More informationicex-cmtm General specs and Installation guide
icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300 CPU 317-2 PN/DP, CENTRAL PROCESSING UNIT WITH 1 MB WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300 CPU 315-2 PN/DP, CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
More informationIndustrial Tri-band 3G Modem GTM-201-3GWA Series. User Manual
Industrial Tri-band 3G Modem GTM-201-3GWA Series User Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to
More informationTELETERM M2 Series Programmable RTU s
Keep control of your assets 365/24/7 DATASHEET Never before has remote sensing and control been as cost effective. With capability for most communication means as well as Internet access there is no longer
More informationTK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router
+70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W The industrial 2G GPRS- and 3G UMTS routers offered by Welotec enables the access to Ethernet devices or a local network remotely via mobile network
More informationCentral processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226
Overview CPU 226 The high-performance package for complex technical tasks With additional PPI port for more flexibility and communication options With 40 inputs/outputs on board Expansion capability for
More informationHardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)
1 (http://nethix.com) Portal (../portal/portal.html) WE110 (../we110/we110.html) WE120 (../we120/we120.html) WE300 (../we300/we300.html) WE500 (we500.html) Quick start guide (we500_qsg.html) Hardware manual
More informationSupply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,
Data sheet SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA, Supply voltage Rated value (DC) 24 V DC Load voltage L+ Rated value (DC) permissible range, lower
More informationHow to connect. Go to Tools / Options / Port Settings (in PlusConfig software) and change the COM port to COM 3. Minelec PlusConfig How to connect
How to connect PlusConfig How to connect with the Luxom system There are 3 different ways of connecting your computer to the Luxom system: - LOCAL - IP - MODEM LOCAL This means that we use a Luxom serial
More informationQuick Start Guide NETL ink Ethernet Gateways
Version en as of FW. Quick Start Guide NETL ink Ethernet Gateways www.helmholz.com Content. Introduction. Checking the Network Situation. Preparing the NETL ink. IP Address Settings on the PG/PC Network
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300 CPU315F-2 PN/DP, CENTRAL PROCESSING UNIT WITH 512 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
More informationQUICK GUIDE for 4 modules. Installation
QUICK GUIDE for 4 modules Installation 1. Prepare a SIM card so that the PIN code is 1234 or is deactivated. Mount the card in the unit. The unit has now 1234 as password or runs without a password. The
More informationL-force remote maintenance
L-force remote maintenance Simple and secure All over the world Meyer Industrie-Electronic GmbH MEYLE Carl-Bosch-Straße 8 49525 Lengerich/Germany Tel.: +49 (0) 5481-9385-0 Fax: +49 (0) 5481-9385-12 Internet:
More informationManual. MB connect line Telefon 07062/ Fernwartungssysteme GmbH Telefax 07062/ Raiffeisenstraße 4 Hotline 09851/55776 D Ilsfeld
Manual MB connect line Telefon 07062/9178788 Fernwartungssysteme GmbH Telefax 07062/9178792 Raiffeisenstraße 4 Hotline 09851/55776 D-74360 Ilsfeld Copyright MB connect line Fernwartungssysteme GmbH 2008.
More informationUser Manual for VE GSM Modem
User Manual for VE GSM Modem INTRODUCTION GSM/GPRS Smart Modem is a multi-functional, ready to use, rugged unit that can be embedded or plugged into any application. The Smart Modem can be controlled and
More informationQuick Start Guide REX 100 3G LTE. Version. 2 en. as of FW
Quick Start Guide REX 100 3G LTE Version 2 en as of FW 1.5.0 www.helmholz.com Content 1. Introduction 3 2. Preparing the REX 100 unit 3 2.1 Connection 3 2.2 Optional wiring of IN1 and IN2 3 2.3 Antenna
More informationStructure and Function
Communication processors Communication processors Structure and Function Communication processors for the connection of different target and source systems, such as via Ethernet to higher-level MES and
More informationTECHNICAL SPECIFICATIONS EN
TECHNICAL SPECIFICATIONS EN Industrial router mbnet MDH800 MDH859 (Item no.: 8810-UL, 8811-UL, 8812-UL, 8813-UL, 8814-UL, 8815-UL, 8816-UL, 8817-UL, 8818-UL, 8819-UL, 8830-UL, 8831-UL, 8833-UL, 8834-UL,
More informationQuick Start Guide REX 300. Version. 1 en. from FW
Quick Start Guide REX 300 Version 1 en from FW 3.7.0 www.helmholz.de Contents 1. Introduction 3 2. Preparing the REX 300 unit 3 3. Access to the portal 4 4. Initial router configuration via the portal
More informationDupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications
Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter
More informationBluetooth TO Serial CONVERTER E-P132-B
Bluetooth TO Serial CONVERTER E-P132-B 1 Table of Contents Introduction..3 Package checklist...4 Product Specification...5 Product Panel Views Description...6 Product Views. 6 DC-In Power Outlet 6 Antenna
More informationRemote networks. Easy remote access to machines and plants. Industrial Remote Communication. Edition 03/2017. Brochure. siemens.com/remote-networks
Industrial Remote Communication Remote networks Easy remote access to machines and plants Brochure Edition 03/2017 siemens.com/remote-networks Many ways of connecting to remote networks Increasing bandwidths,
More informationEasyConnect PROFIBUS-Connector, 90
32 Catalog 10 Bus Connectors Repeater Active Dropcable Terminal Block DP/DP Coupler Ethernet Gateways OPC Server Systeme Helmholz GmbH 91091 Großenseebach Phone: +49 9135 7380-0 Fax: +49 9135 7380-110
More informationAdvant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System
Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.
More informationChapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer
Chapter 11: Input/Output Organisation Lesson 05: Asynchronous RS232C Serial Port data transfer Objective Understand the RS232C asynchronous data transfer and signals Learn the RS232C serial port communication
More informationLM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)
Bluetooth v2.0, v2. RS232 Serial Adapter - SMA Connector Revised 3/MAR/20 Datasheet Version.0 mm mm 34mm Features Bluetooth v2.0, v2. wireless technology dbm Tx Power and - dbm Rx Sensitivity Serial (RS232)
More informationBluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual
Bluetooth to RS-232 Converter RT-132B Bluetooth Adaptor Operation Manual First Edition, Nov 2007 Table of Contents 1. Introduction.. 2 2. Package checklist.. 3 3. Product Specification... 4 4. Product
More informationSender Receiver Sender
EEE 410 Microprocessors I Spring 04/05 Lecture Notes # 19 Outline of the Lecture Interfacing the Serial Port Basics of Serial Communication Asynchronous Data Communication and Data Framing RS232 and other
More information1 port RS-232 Device Server
1 port RS-232 Device Server Ethernet RJ45 1 Port Transmit and receive and Ethernet Link and 100/10M LED drive. 10/100 Mbps, auto MDI/MDIX Gateway IP address Serial Interface 1 Port 15 KV ESD protection
More informationIntroducing. Australia s First LTE Category 1 Serial + USB Modem for IoT Applications. Intercel Pty. Ltd. ABN
Introducing Australia s First LTE Category 1 Serial + USB Modem for IoT Applications Intercel Pty. Ltd. ABN 13 007 077 161 33 Glenvale Crescent Mulgrave VIC, Australia 3170 Phone: 03 9239 2000 Email: intercel@intercel.com.au
More informationCPU 412H. Function. Parameterizable properties
CPU 412H Function Block protection: In addition to the keylock switch, a password concept protects the user program from unauthorized access. Integrated HMI services: In the case of HMI devices, the user
More informationTeleService of a S station via mobile network
Application Example 10/2016 TeleService of a S7-1200 station via mobile network CP 1242-7 V2, CP 1243-7 LTE, TCSB V3 https://support.industry.siemens.com/cs/ww/en/view/56720905 Warranty and Liability Warranty
More informationDocument Name : User Manual for SC10B : RS232 to Bluetooth Converter.
Document Name : User Manual for SC10B : RS232 to Bluetooth Converter. SC10B is Bluetooth V.2.0-certified and is backward compatible with v1.1/1.2 devices. You can connect between your computers (Master)
More informationBLE232: Manual Copyright 2014 taskit GmbH
BLE232 Manual BLE232: Manual Copyright 2014 taskit GmbH BLE232 All rights to this documentation and to the product(s) described herein are reserved by taskit GmbH. This document was written with care,
More informationW&T Manual Interface modules W&T
Manual Subject to error and alteration Model 18801, 18811 18802, 18812 18803, 18813, 18833 18601, 18611 18602, 18612 18613, 18633 18401, 18411 18402, 18412 Release 1.7 43 09/2013 by Wiesemann und Theis
More informationhttps://support.industry.siemens.com/cs/ww/de/view/
Operating System Update (OS Update) ProSave https://support.industry.siemens.com/cs/ww/de/view/19701610 Siemens Industry Online Support Siemens AG 2017 All rights reserved This entry originates from Siemens
More informationProduct type designation. General information. Supply voltage
Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1
More informationData sheet VIPA CPU M13C (M13-CCF0000)
Data sheet VIPA CPU M13C (M13-CCF0000) Technical data Order no. M13-CCF0000 Type VIPA CPU M13C Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power
More informationPCM-36E06. PC/104 Advanced Communications Module. User Manual Rev 0.2
PCM-36E06 PC/104 Advanced Communications Module User Manual Rev 0.2 +DISCLAIMER... 3 INTRODUCTION... 4 GPS MODULE... 4 DIAL-UP MODEM MODULE... 5 CELL MODEM MODULE... 5 SPECIFICATIONS... 5 UARTS...5 GPS
More informationTS Adapter IE SIMATIC. Industrial Software Engineering Tools TS Adapter IE. Introduction 1. Properties of the TS Adapter IE
Introduction 1 Properties of the TS Adapter IE 2 SIMATIC Industrial Software Engineering Tools Manual Requirements for Operation 3 Mounting 4 Connecting 5 Commissioning 6 Working with the 7 Error diagnostics
More informationISDN OEM1. DesignGuide V1.2
ISDN OEM1 DesignGuide V1.2 Content ISDN OEM1...1 1 Objective...3 2 Product description...3 3 Software interfaces...4 3.1 Dialing procedures...4 3.2 AT commands...4 3.2.1 Configuration commands...4 3.2.2
More informationIndustrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual
Industrial Quad-band GPRS/GSM Modem GTM-201 Series User Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery
More informationCP ADVANCED. Function
CP 343-1 ADVANCED Function The CP 343-1 Advanced independently handles data traffic over Industrial Ethernet. The module has its own processor and can be put into service directly using the unique preset
More informationData Sheet HG400/HG Energy Monitoring with M-Bus: Up to 100 M-Bus energy meters can be monitored by a single Tixi Alarm Modem
Data Sheet HG400/HG100 28.3.2009 Tixi Alarm Modem GSM Remote Control Fault Messaging Data Logging Web Server PLC Protocols Energy Monitoring with : Up to 100 energy meters can be monitored by a single
More informationHit Copyright
datasheet Contents 1. Copyright 2. Introduction 3. Block diagram 4. Connectors pin-out 5. Power supply ratings 6. RS232 interface description 7. USB interface description 8. Important remarks prior to
More informationTIM DNP3 SIMATIC NET. Industrial Remote Communication - Telecontrol TIM DNP3. Preface. Uses and properties of the TIM
Preface Uses and properties of the TIM 1 SIMATIC NET Industrial Remote Communication - Telecontrol System Manual Network structures and configurations 2 LEDs and connectors 3 Installation and commissioning
More informationQUADIMODO. Quad-Band IP68 GSM MODEM. Quad Band for Worldwide Use. IP68 Enclosure Submersible. Voice / Fax / SMS and Data. GPRS Class B Class 10:
Quad-Band IP68 GSM MODEM Quad Band for Worldwide Use IP68 Enclosure Submersible Voice / Fax / SMS and Data GPRS Class B Class 10: Bundled 3V SIM Card included Internal Antenna (Optional External) RS232
More informationGPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher
GPRS ADAPTER INSTALLATION AND USER MANUAL for module version v2.24 and higher Table of contents 1 Main function of the Adapter...3 2 System operation...3 2.1 Transmission through GPRS...4 2.1.1 Router
More informationISDN - SOC. DesignGuide. Rev 2.2
ISDN - SOC DesignGuide Rev 2.2 Content 1 Objective... 3 2 Product description... 3 3 Software interfaces... 4 3.1 Dialing procedures... 4 3.2 AT commands... 4 Configuration commands... 4 AT connection
More informationFour-Faith Smart Power Technology Co., Ltd. F1103 GPRS MODEM USER MANUAL
F1103 GPRS MODEM USER MANUAL Contents Chapter 1 Brief Introduction of Product... 3 1.1 General...3 1.2 Features and Benefits... 3 1.3 Working Principle...3 1.4 Specifications... 4 Chapter 2 Installation
More information/
WWW.INFOPULSAS.LT / info@infopulsas.lt HANDBOOK MB Connect Line GmbH Raiffeisenstraße 4 D-74360 Ilsfeld Telephone +49 (0)7062/9178788 Fax +49 (0)7062/9178792 Hot line +49 (0)9851/582529-0 Copyright MB
More informationCPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design
CPU 224 The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design The CPU 224 is equipped with the following: Integral 24 V encoder/load current
More informationCable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB
APPENDIXB This appendix lists the cable specifications for supported modules on the Cisco 7600 series router. The following signal summaries are contained in this appendix: Interface Specifications, page
More informationThe System for Power Automation
Basics 1 Tasks and solution The System for Automation The Tasks: Scalable system for Distributed process connection Process visualization Interface to control centre The Solution: Automation System PTD-SE-A2/
More information