APD-8 8-Channel FRAD / X.25 PAD

Size: px
Start display at page:

Download "APD-8 8-Channel FRAD / X.25 PAD"

Transcription

1 Installation and Operation Manual APD-8 8-Channel FRAD / X.25 PAD

2

3 APD-8 8-Channel FRAD / X.25 PAD Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the APD-8 and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD. APD-8 is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the APD-8. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the APD-8, based on or derived in any way from the APD-8. Your undertaking in this paragraph shall survive the termination of this Agreement. This Agreement is effective upon your opening of the APD-8 package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the APD-8 and all copies and portions thereof. For further information contact RAD at the address below or contact your local distributor. International Headquarters RAD Data Communications Ltd. 24 Raoul Wallenberg St. Tel Aviv Israel Tel: Fax: market@rad.com North America Headquarters RAD Data Communications Inc. 900 Corporate Drive Mahwah, NJ USA Tel: (201) , Toll free: Fax: (201) market@radusa.com RAD Data Communications Ltd. Publication No /06

4 Limited Warranty RAD warrants to DISTRIBUTOR that the hardware in the APD-8 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR. If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the appropriate corrective action: a) supply a replacement part, or b) request return of equipment to its plant for repair, or c) perform necessary repair at the equipment's location. In the event that RAD requests the return of equipment, each party shall pay one-way shipping costs. RAD shall be released from all obligations under its warranty in the event that the equipment has been subjected to misuse, neglect, accident or improper installation, or if repairs or modifications were made by persons other than RAD's own authorized service personnel, unless such repairs by others were made with the written consent of RAD. The above warranty is in lieu of all other warranties, expressed or implied. There are no warranties which extend beyond the face hereof, including, but not limited to, warranties of merchantability and fitness for a particular purpose, and in no event shall RAD be liable for consequential damages. RAD shall not be liable to any person for any special or indirect damages, including, but not limited to, lost profits from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, repair, maintenance or use of the APD-8, and in no event shall RAD's liability exceed the purchase price of the APD-8. DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makes relating to APD-8 and for ensuring that replacements and other adjustments required in connection with the said warranties are satisfactory. Software components in the APD-8 are provided "as is" and without warranty of any kind. RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose. RAD shall not be liable for any loss of use, interruption of business or indirect, special, incidental or consequential damages of any kind. In spite of the above RAD shall do its best to provide error-free software products and shall offer free Software updates during the warranty period under this Agreement. RAD's cumulative liability to you or any other party for any loss or damages resulting from any claims, demands, or actions arising out of or relating to this Agreement and the APD-8 shall not exceed the sum paid to RAD for the purchase of the APD-8. In no event shall RAD be liable for any indirect, incidental, consequential, special, or exemplary damages or lost profits, even if RAD has been advised of the possibility of such damages. This Agreement shall be construed and governed in accordance with the laws of the State of Israel.

5 Product Disposal To facilitate the reuse, recycling and other forms of recovery of waste equipment in protecting the environment, the owner of this RAD product is required to refrain from disposing of this product as unsorted municipal waste at the end of its life cycle. Upon termination of the unit s use, customers should provide for its collection for reuse, recycling or other form of environmentally conscientious disposal. General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols Warning This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel. Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines.. Protective earth: the marked lug or terminal should be connected to the building protective earth bus. Warning Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached. Please observe the following precautions: Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter. Do not attempt to adjust the laser drive current. Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam. The use of optical devices with the equipment will increase eye hazard. Use of controls, adjustments or performing procedures other than those specified herein, may result in hazardous radiation exposure. ATTENTION: The laser beam may be invisible!

6 In some cases, the users may insert their own SFP laser transceivers into the product. Users are alerted that RAD cannot be held responsible for any damage that may result if non-compliant transceivers are used. In particular, users are warned to use only agency approved products that comply with the local laser safety regulations for Class 1 laser products. Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user. General Safety Practices Handling Energized Products Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist. Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts. Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets. Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground. Connection of AC Mains Make sure that the electrical installation complies with local codes. Always connect the AC plug to a wall socket with a protective ground. The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A. Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation. In cases when the power distribution system is IT type, the switch must disconnect both poles simultaneously. Connection of DC Mains Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded. Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards. DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel. Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes.

7 The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A. Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation. If the DC mains are floating, the switch must disconnect both poles simultaneously. Connection of Data and Telecommunications Cables Data and telecommunication interfaces are classified according to their safety status. The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manual. Ports Safety Status V.11, V.28, V.35, V.36, RS-530, X.21, 10 BaseT, 100 BaseT, Unbalanced E1, E2, E3, STM, DS-2, DS-3, S-Interface ISDN, Analog voice E&M SELV Safety Extra Low Voltage: Ports which do not present a safety hazard. Usually up to 30 VAC or 60 VDC. xdsl (without feeding voltage), Balanced E1, T1, Sub E1/T1 FXS (Foreign Exchange Subscriber) FXO (Foreign Exchange Office), xdsl (with feeding voltage), U-Interface ISDN TNV-1 Telecommunication Network Voltage-1: Ports whose normal operating voltage is within the limits of SELV, on which overvoltages from telecommunications networks are possible. TNV-2 Telecommunication Network Voltage-2: Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are not possible. These ports are not permitted to be directly connected to external telephone and data lines. TNV-3 Telecommunication Network Voltage-3: Ports whose normal operating voltage exceeds the limits of SELV (usually up to 120 VDC or telephone ringing voltages), on which overvoltages from telecommunication networks are possible. Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a qualified safety engineer. Always make sure that the equipment is grounded before connecting telecommunication cables. Do not disconnect the ground connection before disconnecting all telecommunications cables.

8 Some SELV and non-selv circuits use the same connectors. Use caution when connecting cables. Extra caution should be exercised during thunderstorms. When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connections should comply with the local codes. The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines. In order to reduce the risk, there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors. Caution To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords. Attention Pour réduire les risques s incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure. Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions. Do not attempt to tamper with any carrier-provided equipment or connection hardware. Electromagnetic Compatibility (EMC) The equipment is designed and approved to comply with the electromagnetic regulations of major regulatory bodies. The following instructions may enhance the performance of the equipment and will provide better protection against excessive emission and better immunity against disturbances. A good earth connection is essential. When installing the equipment in a rack, make sure to remove all traces of paint from the mounting points. Use suitable lock-washers and torque. If an external grounding lug is provided, connect it to the earth bus using braided wire as short as possible. The equipment is designed to comply with EMC requirements when connecting it with unshielded twisted pair (UTP) cables. However, the use of shielded wires is always recommended, especially for high-rate data. In some cases, when unshielded wires are used, ferrite cores should be installed on certain cables. In such cases, special instructions are provided in the manual. Disconnect all wires which are not in permanent use, such as cables used for one-time configuration. The compliance of the equipment with the regulations for conducted emission on the data lines is dependent on the cable quality. The emission is tested for UTP with 80 db longitudinal conversion loss (LCL). Unless otherwise specified or described in the manual, TNV-1 and TNV-3 ports provide secondary protection against surges on the data lines. Primary protectors should be provided in the building installation. The equipment is designed to provide adequate protection against electro-static discharge (ESD). However, it is good working practice to use caution when connecting cables terminated with plastic connectors (without a grounded metal hood, such as flat cables) to sensitive data lines. Before connecting such cables, discharge yourself by touching earth ground or wear an ESD preventive wrist strap.

9 FCC-15 User Information This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the Installation and Operation manual, may cause harmful interference to the radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Canadian Emission Requirements This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Warning per EN (CISPR-22) Warning This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user will be required to take adequate measures. Avertissement Cet appareil est un appareil de Classe A. Dans un environnement résidentiel, cet appareil peut provoquer des brouillages radioélectriques. Dans ces cas, il peut être demandé à l utilisateur de prendre les mesures appropriées. Achtung Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkströrungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.

10 Declaration of Conformity Manufacturer's Name: Manufacturer's Address: RAD Data Communications Ltd. 24 Raoul Wallenberg St. Tel Aviv Israel Declares that the product: Product Name: APD-8 Conforms to the following standard(s) or other normative document(s): EMC: EN (1994) Limits and methods of measurement of radio disturbance characteristics of information technology equipment. EN (1992) Electromagnetic compatibility Generic immunity standards for residential, commercial and light industry. Safety: EN (1992/93) Safety of information technology equipment, including electrical business equipment. Supplementary Information: The product herewith complies with the requirements of the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC. The product was tested in a typical configuration. Tel Aviv, 29 October 1996 Haim Karshen VP Quality European Contact: RAD Data Communications GmbH, Otto-Hahn-Str , Ottobrunn-Riemerling, Germany

11 Contents Chapter 1. Introduction 1.1 Overview Technical Specifications Chapter 2. Installation 2.1 Introduction Unpacking Site Requirements Power Data Channel Connections Main Links Connections Front and Rear Panel Clearance Ambient Requirements Hardware Configuration Information General Information Internal Jumpers INIT-NOR Jumper, (JP11) INIT Link 1 Jumper, (JP15) Interface Board Jumper Setting Procedure Installation in 19" Racks Installation of a Single Unit Installation of Two Units Cable Connections Asynchronous Data Channel Connections Synchronous Link Connection Power Connection Chapter 3. Operation 3.1 Overview Controls, Indicators and Connectors Front Panel Controls, Indicators and Connectors Rear Panel Controls and Connectors Operating Procedure Power-On Normal Operation Power-Off Upgrading the Software Troubleshooting Appendix A. Connector Pinouts APD-8 i

12 Table of Contents Installation and Operation Manual ii APD-8

13 Chapter 1 Introduction 1.1 Overview APD-8 is a multiprotocol FRAD that provides access to public or private Frame Relay networks. Asynchronous data is sent directly over the Frame Relay or encapsulated over X.25 / Frame Relay (Annex G), to achieve maximum reliability APD-8 has one synchronous port which supports data rates up to 2 Mbps. The synchronous port can be configured to either X.25 or Frame Relay. The synchronous port can be V.24, V.35, X.21 or RS-530. Interfaces V.24 and V.35 for the port can be DCE or DTE layer 1 (per order). The X.21 and RS-530 interfaces can only be DTE. An optional ISDN, U-INT or DDS (always DTE layer 1) interface can be provided for the port. APD-8 can connect up to eight asynchronous channels. The asynchronous channels can be configured as X.28 or SLIP and operate at data rates up to kbps. APD-8 supports a wide range of applications. For information on the APD-8 features and applications, refer to the RAD Packet Switching Applications Guide. APD-8 Overview 1-1

14 Chapter 1 Introduction Installation and Operation Manual 1.2 Technical Specifications General Number of Ports 1 synchronous Indicators 8 asynchronous Power Main links activity Sub-channels activity Loss of synchronization Error Overflow Test Packet Size Up to 4096 bytes for X.25 Throughput RAM Size Synchronous Link Number of Ports 1 Asynchronous Channels Data Rate Up to 8K for other protocols 500 packets per second 2 MB Up to 2 Mbps Interface RS-232/V.24, X.21, V.35, RS-530, DDS, U- INT, ISDN (specified in purchase order) Connectors Clocking Number of Channels 8 Data Rate Interface Connector Flow Control RS-232/V.24: 25-pin D-type, female (DCE, DTE) X.21: 15-pin, female (DTE) V.35: 34-pin, female (DCE, DTE) RS-530: 25-pin D-type, female (DTE) DDS: CSU/DSU interface, UTP cable, RJ-45 ISDN: S-interface, UTP cable, RJ-45 External clocking for receive and transmit paths. Internal clock for DCE interfaces. 75 bps to Kbps, programmable RS-232/V.24 (DCE) RJ-45 XON/XOFF or RTS/CTS flow control 1-2 Technical Specifications APD-8

15 Installation and Operation Manual Chapter 1 Introduction Channel Log-on Messages Command Modes Herald and bulletin (user-definable) CCITT Rec. X.28 and proprietary extensions CCITT Rec. X.29 Terminal Handling Enhanced, handling beyond CCITT Rec. X.3 requirements Power Supply Voltage 115 or 230 V ac (in accordance with order), 50/60Hz Consumption Fuse 15 W 125 ma, 250 V Physical Height 4.4cm (1.7 in) Width Depth Weight 21.6 cm (8.5 in) 24.6cm (9.5 in) 1.8 kg (3.9 lb) Environment Temperature 0 50 C ( F) Humidity Up to 90%, non-condensing APD-8 Technical Specifications 1-3

16 Chapter 1 Introduction Installation and Operation Manual 1-4 Technical Specifications APD-8

17 Chapter 2 Installation 2.1 Introduction This chapter provides mechanical and electrical installation procedures for APD-8. APD-8 is delivered completely assembled. It can be installed as a desktop unit or mounted in a 19 rack. After installing the unit, see the RAD Packet Switching Guide for system configuration information and procedures. If a problem is encountered, see the RAD Packet Switching Guide for troubleshooting and diagnostic testing instructions. 2.2 Unpacking Perform a preliminary inspection of the equipment container before unpacking. Note any evidence of damage and report it immediately. To unpack the equipment: 1. Place the container on a clean flat surface, cut all straps, and open or remove the top cover. 2. Take out the unit carefully and place it securely on a clean surface. 3. Inspect the product and report any damage immediately. 2.3 Site Requirements Power Install the APD-8 unit within 1.5 m (5 ft) of an easily-accessible grounded AC outlet that supplies 115 or 230 VAC, in accordance with the nominal supply voltage of your APD-8 (preferred voltage must be specified in your order). Data Channel Connections APD-8 has eight RJ-45 connectors - one for each asynchronous data channel. APD-8 Site Requirements 2-1

18 Chapter 2 Installation Installation and Operation Manual Main Links Connections The APD-8 main links connector depends on the interface supplied with the device. RS-232/V24: - 25-pin D-type, female connector X.21: - 15-pin, female connector V.35: - 34-pin, female connector RS-530: - 25-pin D-type, female connector DDS: - CSU/DSU interface, UTP cable, RJ-45 ISDN: - S-interface, UTP cable, RJ-45. Appendix A provides the pin allocations. Front and Rear Panel Clearance Ambient Requirements If the APD-8 is installed in a 19" rack, leave at least 90 cm (36") of frontal clearance for operator access. Leave at least 10cm (4") clearance at the rear of the unit for interface cable connections. The ambient operating temperature of the APD-8 should be 0 to 50ºC (32 to 122ºF), at a relative humidity of up to 90%, non-condensing. General Information Note 2.4 Hardware Configuration Information The APD-8 has one main board which contains: 1 jumper for hardware configuration of the APD-8. A CPU that runs the APD-8 software. FLASH memory that receives downloaded software from a connected terminal. This section provides descriptions of the functions of the internal jumpers, and provides step-by-step jumper setting instructions. The default settings for each jumper are also listed. The default settings of the APD-8 jumpers are suitable for most applications. If your requirements are different, set the jumpers in accordance with your requirements before APD-8 installation. Following installation, all other configuration actions are performed through the APD-8 command facility. For more information, see the RAD Packet Switching Guide. 2-2 Hardware Configuration Information APD-8

19 Installation and Operation Manual Chapter 2 Installation Internal Jumpers Warning Figure 2-1. APD-8 Boards Figure 2-2 shows the locations of the jumpers on the APD-8 main board. To avoid the danger of an electrical shock, always turn the power switch off and disconnect the power cable from the power source before opening the unit. INIT-NOR Jumper, (JP11) This jumper determines the unit's active configuration at startup. NOR Normal operation APD-8 uses the parameters selected by the user during the last configuration session. APD-8 Hardware Configuration Information 2-3

20 Chapter 2 Installation Installation and Operation Manual INIT Initialization When the unit is switched on, it loads the default configuration. The factory setting is NOR. Link 1 Jumper, (JP15) Controls link 1. Interface Board Figure 2-2. APD-8 Jumper Locations APD-8 is available with seven types of removable interface boards: V.24 (RS-232) interface for DTE and DCE V.35 interface for DTE and DCE RS-530 interface for DTE X.21 interface for DTE DDS interface for DTE ISDN. 2-4 Hardware Configuration Information APD-8

21 Installation and Operation Manual Chapter 2 Installation Warning To avoid the danger of electrical shock, always turn the power switch off and disconnect the power cable from the power source before opening the APD-8. The interface board determines the physical layer configuration of an APD-8 link. Each interface board is configured either as DCE or DTE. When the board is a DCE interface board, use a flat cable to connect the link to a terminal. The link supplies its clock and the clock parameter must be configured as internal clock (see the RAD Packet Switching Guide). If the board is a DTE interface board, the link uses the APD-8 internal clock and the clock parameter must be configured as external clock (see the RAD Packet Switching Guide). Jumper Setting Procedure To change the jumper setting: 1. To access the main board of the unit, remove the screw fastening the top cover to the case, and remove the top cover. 2. See Figure 2-2 and identify the jumper locations and settings. Change settings if required. 3. Reattach the APD-8 cover, and tighten its screw. Do not exert excessive torque while tightening these screws. Warning 2.5 Installation in 19" Racks APD-8 can be installed in 19" racks. The unit's height corresponds to 1U (1.75"). The width of the unit is slightly less than the available mounting width. Two rack adapter kits are available for APD-8. One adapter kit provides the required hardware to install a single device. The other kit provides the required hardware to install two devices side by side. Disconnect the units from AC power before performing the following procedures. APD-8 Installation in 19" Racks 2-5

22 Chapter 2 Installation Installation and Operation Manual Installation of a Single Unit The single APD-8 adapter installation kit includes one short bracket and one long bracket. To prepare the device for rack installation (see Figure 2-3): 1. Attach the two brackets by inserting the two screws into the front holes on the two side walls of the device (nuts are already in place, on the inner side of the walls). 2. Tighten the screws. 3. After attaching the brackets, fasten the brackets to the side rails of the rack by inserting and tightening four screws (not included in the kit), two on each side. Installation of Two Units Figure 2-3. Installing a Single APD-8 in a 19" Rack The dual APD-8 adapter installation kit includes two long side rails (one for each unit) and two short side brackets. The long side rails slide together, thus joining the two units together, and the short side brackets hold the two units in the 19" rack. To prepare the devices for rack installation (see Figure 2-4): 1. Fasten the long side rails to each unit separately using the four screws supplied (right side to one unit, left side to the second unit). 2. Attach one short bracket opposite the side rail of each unit using the two screws supplied. 3. Slide the two rails together. This is done by fitting the outer flange into the groove so that the top and bottom flanges fit tightly into each other. 2-6 Installation in 19" Racks APD-8

23 Installation and Operation Manual Chapter 2 Installation 4. Place the black plastic caps in the ends of the rails to prevent movement in the units and to protect the rail ends. 5. Place the assembled units in the rack and fasten the brackets to the side rails of the rack, using the two screw holes situated on each side. The screws are not included in the kit since they are supplied with the rack. Figure 2-4. Installing Two APD-8s in a 19" Rack APD-8 Installation in 19" Racks 2-7

24 Chapter 2 Installation Installation and Operation Manual 2.6 Cable Connections APD-8 has one connector on the rear panel that serves the synchronous link and eight RJ-45 connectors on the front panel for the asynchronous data channels. Asynchronous Data Channel Connections The APD-8 channel interfaces are configured as data communication equipment (DCE) interfaces, thereby allowing direct connection, through RS-232 port cables, to data terminal equipment (DTE). If modems are used to extend the range (tailend circuits), cross-over cables are required. Channel interfaces are asynchronous, so clock signals are not supported or required. Synchronous Link Connection The synchronous link connector type depends on the APD-8 interface: RS-232/V24: 25-pin D-type, female connector, DTE or DCE X.21: 15-pin, female connector V.35: 34-pin, female connector, DTE or DCE RS-530: 25-pin D-type, female connector DDS: 8-pin RJ-45, female connector ISDN: RJ-45 connector. Appendix A lists the pin allocations for the various links connectors. Note The user data cables and the synchronous links cables should be shielded, in order to comply with FCC rules. The APD-8 and its data interfaces will work well even if the cables are not shielded, but some radio interference may occur. Power Connection Warning AC power is supplied to the unit through the 5 ft (1.5 m) power cable terminated by a standard 3-prong plug. Connect the cable between the AC power connector on the APD-8 rear panel and a standard grounded AC power outlet. BEFORE SWITCHING ON THIS UNIT, connect the protective earth terminals of this device to the protective ground conductor of the power cord. Insert the power cord plug only into an outlet that has a protective earth contact. Do not negate this protective action by using an extension cord (power cable) without a protective conductor (grounding). Interrupting the protective grounding conductor (inside or outside the unit) or disconnecting the protective earth terminal can make this instrument dangerous. Intentional interruption is prohibited. When replacing fuses, use only fuses with the required rated current, as marked on the APD-8 rear panel. Avoid using repaired fuses and shortcircuiting fuse holders. If you suspect that the protection offered by fuses has been impaired, make the instrument inoperative and secure it against unintended operation. 2-8 Cable Connections APD-8

25 Chapter 3 Operation 3.1 Overview APD-8 supports a wide range of applications, such as: An access unit to X.25 private or public networks An access server to X.25 ports of mainframes An asynchronous switch and contention A FRAD to run asynchronous data in X.25 packets over Frame Relay A FRAD to run asynchronous data directly over Frame Relay (for example, SLIP protocol over Frame Relay). For more information, refer to the RAD Packet-Switching Application Guide. 3.2 Controls, Indicators and Connectors Front Panel Controls, Indicators and Connectors Table 3-1 lists the functions of the APD-8 front panel indicators and connectors. The numbers listed under Item refer to the identification numbers in Figure 3-1. Figure 3-1. APD-8 Front Panel Controls, Indicators and Connectors APD-8 Controls, Indicators and Connectors 3-1

26 Chapter 3 Operation Installation and Operation Manual Table 3-1. APD-8 Controls, Indicators and Connectors Description Item Control, Indicator or Connector Function 1 PWR Indicator On when APD-8 is powered 2 Main Link Activity Indicators On when the link is active (receives or transmits frames) 3 Channel Activity Indicators (one for each channel) On when the corresponding channel is active (receives or transmits data) 4 SYNC Indicators Indicates the synchronization status: Off when the unit is not powered On when the unit is powered and synchronized with the corresponding peer. Blinks continuously when the unit is powered, but not synchronized with its peer. 5 ERR Indicator On when a hardware malfunction was detected during the self-test. 6 OVF Indicator On when the buffers are full. This condition usually indicates that one of the DTE units connected to the unit does not respond to the unit's flow control commands, a condition that may be caused by incorrect configuration of APD-8. 7 TEST Indicator On when the APD-8 is in the diagnostics mode (a test loop is active). Traffic is not interrupted. 8 RESET Button Resets the unit's internal circuits (including the data buffers) and initiates the power-up self-test. 9 Channel Connectors Connection to the APD-8 channels (one connector per channel) 3-2 Controls, Indicators and Connectors APD-8

27 Installation and Operation Manual Chapter 3 Operation Rear Panel Controls and Connectors Table 3-2 lists the functions of the APD-8 rear panel controls and connectors. The numbers under the heading Item refer to the identification numbers in Figure 3-2. Figure 3-2. APD-8 Rear Panel Controls and Connectors Table 3-2. APD-8 Rear Panel Controls and Indicators Item Control or Connector Function 1 Power Connector AC power connector with integral fuse 2 Power Switch Turns the unit on 3 Links Connectors Connection to link Note Power-On 3.3 Operating Procedure APD-8 normally operates unattended. Operator intervention is only required when setting up the unit for the first time or when adapting it to new operational requirements. The APD-8 configuration is stored in a non-volatile memory, and is not affected when power is turned off. To activate the unit: 1. Connect the power cable to the APD-8 rear power connector. 2. Set the power switch to ON. The PWR indicator turns on. If the link to its synchronous DTE/DCE peer is not operational yet, the SYNC indicator of APD-8 blinks. Wait until the link becomes operational, and check that the SYNC indicator stops blinking and lights continuously. 3. Check that the ERR, OVF and TEST indicators turn off after the unit's self-test. APD-8 Operating Procedure 3-3

28 Chapter 3 Operation Installation and Operation Manual Normal Operation During normal operation, the PWR, SYNCs and MAINs indicators light continuously and the TEST, OVF and ERR indicators must remain off. Channel activity indicators blink according to the traffic load, and turn off if the channel is idle. Power-Off To turn the APD-8 off: Set the power switch to OFF. 3.4 Upgrading the Software The product family supports a flash memory which enables updating the software via a terminal. It is not necessary to replace the EPROMs to upgrade the software. Once connected to the terminal, follow on-screen instructions to perform the upgrade. To upgrade the software: 1. Connect the terminal to port no.1 on the device. 2. From the Main menu, select option 2. The System Control menu appears. SYSTEM CONTROL MENU 1.) Link down 2.) Link up 3.) Clear Channel 4.) Clear LCN 5.) Update date 6.) Update time 7.) Reset statistics 8.) Rearrange NOVRAM 9.) Reset 10.) Set default configuration 11.) Disconnect dial link 12.) Enable software upgrade <Enter> EXIT Figure 3-3. System Control Menu 3-4 Upgrading the Software APD-8

29 Installation and Operation Manual Chapter 3 Operation 3. From the System Control menu, select option 12. The following screen appears: WARNING!!! THIS ACTION WILL ENABLE YOU TO DOWNLOAD A NEW SOFTWARE VERSION AFTER RESET. Type: LINK1 for download through link 1. CHAN1 for download through front channel 1. You should connect a terminal configured: 9600, N, 8, 1 to the desired port. 4. Type CHAN1 and press <Enter>. Figure 3-4. Warning Message 5. Reset the device by pressing the RESET button on the front panel of the module. If a problem occurs during the software download, the following screen appears: Software Upgrade System Please select one of the following: 1) 9600 bit/s 2) bit/s 3) bit/s 4) bit/s 5) bit/s 6) Run the existing software (NO download) Figure 3-5. Software Upgrade System Menu 6. Select option 6 to run the existing software. The following message appears: CHANNEL NUMBER 1 Figure 3-6. Channel Message Number 7. When the software is downloaded successfully, the following message appears: Software Upgrade System Software successfully loaded Figure 3-7. Software Upgrade System Message APD-8 Upgrading the Software 3-5

30 Chapter 3 Operation Installation and Operation Manual 3.5 Troubleshooting If a problem occurs, you can perform the following preliminary steps to return APD-8 to normal operation. To perform preliminary troubleshooting: 1. Check if the unit is turned on (PWR indicator is on). 2. Check if the cables are properly connected. 3. Check if the equipment connected to the unit is turned on and operates normally. 4. Check the LED indicators. 5. Check if the configurations of the APD-8 PAD and the remote PAD or switch correspond to the requirements of the equipment connected to its channels. 6. If steps 1 to 5 do not correct the problem, press RESET or turn the unit off and then on again. If the problem persists, see Chapter 5 in the RAD Packet Switching Guide for additional solutions. 3-6 Troubleshooting APD-8

31 Appendix A Connector Pinouts This appendix provides information needed for the APD-8 interface connections. The information presented in this appendix includes a description of the Control connector, connector pin functions and where applicable the recommended wiring for relevant adapter cables. X.21 Port Pinouts A.1 Interface Connectors V.24 Port Pinouts APD-8 Interface Connectors A-1

32 Appendix A Connector Pinouts Installation and Operation Manual V.35 Port Pinouts V.36 Port Pinouts A-2 Interface Connectors APD-8

33 Installation and Operation Manual Appendix A Connector Pinouts RS-530 Port Pinouts A.2 Control Connector The control connector of APD-8 is an RJ-45 8-pin female connector with a serial RS-232 DCE interface, intended for connection to an ASCII-based terminal. Connector pin functions are listed in Table A-1. To connect a supervision terminal having a 9-pin connector to the control connector, use the appropriate adapter cable (CBL-RJ45/D9/F/STR or CBL-RJ45/D9/M/STR, supplied). Figure A-1 shows the wiring diagram of this cable. Table A-1. RJ-45 Control Connector Pin Functions Pin Function 1 GND 2 Not connected 3 Receive Data (RXD) from terminal 4 Not connected 5 Transmit Data (TXD) to terminal 6 Not connected 7 GND 8 Not connected Terminal Control Table The terminal control port cable has an 8-pin RJ-45 connector on one side, and a 9-pin, D-type, female connector on the other side. APD-8 Control Connector A-3

34 Appendix A Connector Pinouts Installation and Operation Manual Figure A-1. Wiring RJ-45 to DB-9 Adapter Cable (CBL-RJ45/DB9/F/STR) A-4 Control Connector APD-8

35 24 Raoul Wallenberg St., Tel Aviv 69719, Israel Tel: , Fax: , Web site: Customer Response Form RAD Data Communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us an with your comments. Thank you for your assistance! Manual Name: APD-8 Publication Number: /06 Please grade the manual according to the following factors: Excellent Good Fair Poor Very Poor Installation instructions Operating instructions Manual organization Illustrations The manual as a whole What did you like about the manual?

36

37 Error Report Type of Error(s) Incompatibility with product or Problem(s): Difficulty in understanding text Regulatory information (Safety, Compliance, Warnings, etc.) Difficulty in finding needed information Missing information Illogical flow of information Style (spelling, grammar, references, etc.) Appearance Other Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.) and attach the page to your fax, if necessary. Please add any comments or suggestions you may have. You are: Distributor End user VAR Other Who is your distributor? Your name and company: Job title: Address: Direct telephone number and extension: Fax number:

38

39

40 INTERNATIONAL HEADQUARTERS: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: Fax: , , NORTH AMERICA HEADQUARTERS: 900 Corporate Drive, Mahwah, N.J , Tel: (201) Toll Free: , Fax: (201) , Publication No /06

SPS-2HS Miniature Packet Switching Access Unit

SPS-2HS Miniature Packet Switching Access Unit Installation and Operation Manual SPS-2HS Miniature Packet Switching Access Unit SPS-2HS Miniature Packet Switching Access Unit Installation and Operation Manual Notice This manual contains information

More information

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company Data Sheet SRM-6A Short-Range Asynchronous Modem The Access Company Features Asynchronous, full-duplex modem Data rates of up to 19.2 kbps SRM-6A transmission range of up to 8 km (5.0 mi) (for 24 AWG)

More information

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company Data Sheet SRM-3A Ultra-Miniature Isolated Short-Range Async Modem The Access Company Features Asynchronous transmission of up to 19.2 kbps Transmission range of up to 13 km (8 miles) Ultra-miniature modem

More information

Installation and Operation Manual FOM-40. High-Speed Fiber Optic Modem. Version 2

Installation and Operation Manual FOM-40. High-Speed Fiber Optic Modem. Version 2 Installation and Operation Manual FOM-40 High-Speed Fiber Optic Modem Version 2 FOM-40 Version 2 High-Speed Fiber Optic Modem Installation and Operation Manual Notice This manual contains information

More information

LRS-101 Broadband Rack

LRS-101 Broadband Rack Installation and Operation Manual LRS-101 Broadband Rack LRS-101 Broadband Rack Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications

More information

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Installation and Operation Manual KHS.U. ISDN "U" Interface Data Module KILOMUX-2100 MODULE

Installation and Operation Manual KHS.U. ISDN U Interface Data Module KILOMUX-2100 MODULE Installation and Operation Manual KHS.U ISDN "U" Interface Data Module KILOMUX-2100 MODULE KHS.U ISDN "U" Interface Data Module Installation and Operation Manual Notice This manual contains information

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs VDSL LAN Extender Products LMC5220A (Standalone Set, AC) LMC5221A (Standalone, AC, CO Unit) LMC5222A (Standalone, AC, CPE Unit) LMC5223A (Standalone Set, Multi-Power) LMC5224A (Standalone, Multi-Power,

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information

CSM200 Expansion Tray

CSM200 Expansion Tray CSM200 Expansion Tray Initial Setup Guide for SANtricity users or VTL environments EC1718-1-E3, Third Edition Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

Infosystem Remote Touchscreen Installation Instructions

Infosystem Remote Touchscreen Installation Instructions Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide AT-PWR01 AT-PWR02 AT-FAN01 Removable Power Supply and Fan Removable Power Supply and Fan Installation Guide for AT-8900,

More information

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide MIL-S24002TGxx 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch User Guide Rev.B 08-DEC2005 Regulatory Approval - FCC Class A - UL 1950 - CSA C22.2 No. 950 - EN60950 - CE - EN55022 Class A - EN55024

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A Stacking Module AT-MCF2000S Installation Guide PN 613-000708 Rev A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

User Guide. Control Box. RoscoLED TM.

User Guide. Control Box. RoscoLED TM. RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260

More information

Data Sheet and Installation

Data Sheet and Installation Data Sheet and Installation TinyBridge-100 Miniature Remote Fast Ethernet Bridge The Access Company Features High-performance miniature remote bridge for Fast Ethernet extension Wire-speed WAN throughput:

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

3M Wrist Strap and Ground Monitor 773. User s Guide

3M Wrist Strap and Ground Monitor 773. User s Guide 3M Wrist Strap and Ground Monitor 773 User s Guide Table of Contents Section Page Safety Information... 2 1 Description... 4 Overview... 4 Performance... 4 2 Installation... 5 Supplied Parts... 5 Wire

More information

USB Ranger 110/410 User Guide

USB Ranger 110/410 User Guide USB Ranger 110/410 User Guide Featuring ExtremeUSB Technology USB Ranger 110/410 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to

More information

Optimux-34 Fiber Optic Multiplexer

Optimux-34 Fiber Optic Multiplexer Data Sheet Optimux-34 Multiple E1, Ethernet, or High-speed Data over E3 or Fiber, up to 110 km (68 miles) Up to 16 E1 links, high-speed data, and Ethernet traffic multiplexed into one E3 copper or fiber

More information

3M RFID Tracking Pad Model 770

3M RFID Tracking Pad Model 770 3M RFID Tracking Pad Model 770 Owners Manual 3M Information and Materials Security 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 xx-xxxx-xxxx-x Rev 1 Copyright 2003 3M IPC. All rights reserved.

More information

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

FCS-155 Fibre Channel to STM-1/OC-3 Converter

FCS-155 Fibre Channel to STM-1/OC-3 Converter Installation and Operation Manual FCS-155 Fibre Channel to STM-1/OC-3 Converter FCS-155 Fibre Channel to STM-1/OC-3 Converter Installation and Operation Manual Notice This manual contains information

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

Enhanced Mini-Chansim Model VCS-232

Enhanced Mini-Chansim Model VCS-232 Enhanced Mini-Chansim Model VCS-232 Operations Manual ViaSat Inc. 6155 El Camino Real Carlsbad, CA 92009 http://www.viasat.com SAFETY WARNING Always observe standard safety precautions during installation,

More information

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281) CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL 10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099 WWW.ROSE.COM LIMITED WARRANTY Rose Electronics warrants the CrystalView Multi to

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A Installation Guide Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit Issue: 052209 PN: 883884-11L Rev. A ii Copyright Notice 2009, Wyse Technology Inc. All rights reserved. This manual and the software

More information

Metro-Optical Transport Access Nodes

Metro-Optical Transport Access Nodes OnSite 1052 & 1063 Series Metro-Optical Transport Access Nodes Quick Start Guide Important This is a Class A device and isnot intended for use in a residential environment. Part Number: 07MOS10xx-QS, Rev.

More information

ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT.

ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT. MIM-2000F Installation Instructions Document Number MIM2-A2-GZ42-00 June 2005 Contents Software and Firmware License Agreement... 1 Product Documentation Online... 3 Unpacking and Inspecting the Equipment...

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment. Model: 2101 Declaration of Conformity Manufacturer: InFocus Corporation 27500 SW Parkway Avenue Wilsonville, OR 97070 We declare under our sole responsibility that this device conforms to the following

More information

GPS Synchronization Module

GPS Synchronization Module GPS 430-II GPS Synchronization Module Introduction Instruction Sheet The GPS 430-II GPS Synchronization Module guarantees that the time clock uncertainty of the Fluke 430-Series II Power Quality Analyzers

More information

Preparing to Install the Cisco AS5350XM Universal Gateway

Preparing to Install the Cisco AS5350XM Universal Gateway CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following

More information

VIP-812A DUAL NETWORKED STATION PORT

VIP-812A DUAL NETWORKED STATION PORT ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS

More information

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE 1000BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE September 2006 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 2 PROPRIETARY DATA All data in this manual

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

2 Mesa Ethernet Dock User s Manual

2 Mesa Ethernet Dock User s Manual owner s manual Mesa Ethernet Dock The Mesa Ethernet Dock is an optional accessory that provides an ethernet port for networking, power input jack, USB client port, and a mounting station for the Mesa Rugged

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

International Headquarters

International Headquarters IE-MediaChassis/1 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com support@bb-elec.com

More information

IE-MediaChassis/1. Operation Manual

IE-MediaChassis/1. Operation Manual IE-MediaChassis/1 Operation Manual FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of the

More information

CPCI-PS24 24V-Power Supply

CPCI-PS24 24V-Power Supply 24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

48-port 10/100TX + 1 SFP Gigabit Port and 1 10/100/1000BASET Port Unmanaged Switch MIL-S4800. User Manual

48-port 10/100TX + 1 SFP Gigabit Port and 1 10/100/1000BASET Port Unmanaged Switch MIL-S4800. User Manual 48-port 10/100TX + 1 SFP Gigabit Port and 1 10/100/1000BASET Port Unmanaged Switch MIL-S4800 User Manual Regulatory Approval - FCC Class A - UL 1950 - CSA C22.2 No. 950 - EN60950 - CE - EN55022 Class A

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide 1 INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER Installation Guide October 2008 VERSITRON, Inc. 83C Albe Drive Newark, DE 19702 800-537-2296 2 PROPRIETARY DATA All data in this manual is proprietary

More information

FOMi-40 Fiber Optic Modem with Remote Management

FOMi-40 Fiber Optic Modem with Remote Management Data Sheet FOMi-40 Provides a secure and long-range data link of up to 100 km (62 mi) Selectable data rates from 56 to 2048 kbps Multimode or single mode operation Extended transmission range up to 100

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

FX Supervisory Controller Wireless TEC Option Card Installation Instructions Installation Instructions Wireless TEC Option Card Date August 29, 2014 FX Supervisory Controller Wireless TEC Option Card Installation Instructions Applications IMPORTANT: The FX Supervisory Controller

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

D-Link Switch User Manual. Table of Contents

D-Link Switch User Manual. Table of Contents Table of Contents About This Guide... 1 Terms/Usage... 1 Copyright and Trademarks... 1 Product Introduction... 2 Package Contents... 2 Product Overview... 2 Front Panel... 2 Rear Panel... 2 Indicator LEDs...

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.

More information

BEETLE /Fusion Compact. Installation Guide

BEETLE /Fusion Compact. Installation Guide BEETLE /Fusion Compact Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

Agilent 70612B K18 Switch Matrix

Agilent 70612B K18 Switch Matrix Agilent 70612B K18 Switch Matrix Hardware Reference Manual Agilent Technologies COPYRIGHT 2000 AGILENT TECHNOLOGIES, INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR

More information

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude Start Here The NETGEAR Model DS108 Dual Speed Hub is a network hub that enables users to mix and match 10 and 100 megabits per second (Mbps) devices on the same network. This capability eliminates the

More information

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard User Manual AIMB-C200 Economical Embedded Chassis for Mini-ITX Motherboard Copyright The documentation and the software included with this product are copyrighted 2010 by Advantech Co., Ltd. All rights

More information

Airmux-400, Airmux-5000 Optional Accessories

Airmux-400, Airmux-5000 Optional Accessories Data Sheet, Optional Accessories Airmux-IDU-H Airmux-HSSU Airmux-OPOE/DC Aimux-MHS-kit Airmux-PoE/GbE Airmux-Lightning-Protection Aimux-PoE/GBE/DC Aimux-PoE/DC Airmux-GSU Airmux-FE-Repeater , Optional

More information

Demo Kit Quick Start Guide

Demo Kit Quick Start Guide Near Field Imaging (NFI) Projected Capacitive Touch Screen Systems Read and understand all safety information contained in this document before using this product. Introduction This is intended to help

More information

USB Ranger 422 User Guide

USB Ranger 422 User Guide USB Ranger 422 User Guide Featuring ExtremeUSB Technology USB Ranger 422 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to Part Numbers:

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

* * Agilent Power Distribution Unit (PDU) Installation Guide

* * Agilent Power Distribution Unit (PDU) Installation Guide Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The

More information

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller ESCORT MEMORY SYSTEMS COBALT C0405-232-01 RFID CONTROLLER High Frequency Passive Radio Frequency Identification Controller INSTALLATION GUIDE How to Install and Configure Escort Memory Systems Cobalt C0405-232-01

More information

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual McPC/Giga-MediaLinX (PCI and Low Profile PCI Version) 10/100/1000 Mbps Operation Manual FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for

More information

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A AT-6102 IEEE 802.3af Universal Multi-voltage PoE Splitter Installation and User Guide PN 613-000635 Rev A Electrical Safety and Emissions Standards Standards: This product meets the following standards.

More information

Rack Input Module Installation Instructions

Rack Input Module Installation Instructions Rack Input Module Installation Instructions DOC. #560105000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set

More information

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product. Hotwire 6205 ADSL Modem Installation Instructions Document Number 6205-A2-GZ40-10 September 2004 Introduction Congratulations on becoming the owner of a Hotwire ADSL USB Modem. You will now be able to

More information

T3 Interface Converters

T3 Interface Converters MT1103A JULY 2003 MT1103A-DC T3 Interface Converters CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day,

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

iq 16 Sync Charge Box

iq 16 Sync Charge Box USER INSTRUCTIONS iq 16 Sync Charge Box (iq 16 SCB Sync Station ) www.lockncharge.com iq 16 Sync Charge Box Contents Overview...1 Specifications...1 Safety instructions...2 Set up...2 How to charge multiple

More information

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

ASMi-52. 2/4-Wire SHDSL Modem FEATURES FEATURES Dedicated managed SHDSL modem Operates over 2-wire and 4-wire lines, enabling service over any copper infrastructure Multiplexes of two data streams (E1, Ethernet, Serial) over SHDSL Utilizes

More information

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i Assembly Guide Model 133i Radio Frequency Interference Notice (USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules,

More information

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual EDG-6528 8-Port Industrial 10/100 Mbps Ethernet Switch User Manual Copyright The documentation and the software included with this product are copyrighted 2005 by Advantech Co., Ltd. All rights are reserved.

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016 FX-DIS1710-0 Part No. 24-10240-17, Rev. B Issued April 2016 Applications The FX-DIS1710 Local Controller Display is a stand-alone display module designed for installation on the front panel of an enclosure.

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

High Power over Ethernet Midspans PD Port Model PD Port Model

High Power over Ethernet Midspans PD Port Model PD Port Model Data and Power on a Single Line High Power over Ethernet Midspans PD-8006-6 Port Model PD-8012-12 Port Model User Guide Notice The information contained herein is believed to be accurate and reliable at

More information

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual 5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800 User's Manual Trademarks Copyright PLANET Technology Corp. 2006. Contents subject to which revision without prior notice. PLANET is a registered

More information