1 RELION 670/650 SERIES and SAM /650 series and SAM600-IO ANSI Accessories

2 Contents 1. Available accessories Mounting kits RHGS cases Test switch module Key switch for settings Combiflex modules Connectors External resistor unit External current transformer unit Interface converter GPS antenna Injection unit REX Coupling capacitor unit REX Shunt resistor unit REX Voltage injection unit RXTTE ESD Field Kit Power Supply Configuration and monitoring tools Cable and dust cover MicroScada tools User interface Ordering Related documents Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any errors that may appear in this document. Drawings and diagrams are not binding. Copyright 2017 ABB. All rights reserved. Trademarks ABB and Relion are registered trademarks of the ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. 2 ABB

3 Issued: March 2018 Revision: G 1. Available accessories Mounting kits M v3 Mounting kits for space-saving mounting in racks, cubicles or on walls IP54 protected mounting capability in cubicles for 670 and 650 series RHGS cases RHGS 6, RHGS 12 and RHGS 30 cases enable mounting of for example Combiflex modules Test switch module Fail-safe testing of IEDs, using test switch RTXP 24 Time saving while all connections for test are made from the front easy to move between IEDs of the same type SEMOD v2 M v2 Combiflex modules Provide functionality such as lock-out, lock-out reset and external contact re-enforcement Supervision Key switch for settings Possibility to lock settings with key switch Connectors Flexible connection of analog and binary signals Screw compression type Terminal blocks suitable for ring-lugs External resistor unit Used with the High impedance differential protection SEMOD v2 M v1 M v2 SEMOD v2 External current transformer unit SEMOD v2 Used for cost effective summation type differential principle Interface converter External interface converter from C37.94 to G703 External interface converter from C37.94 to G703.E1 M v2 COMBIFLEX Injection equipment RXTTE4 and optional protective resistor are used to inject fundamental frequency AC voltage into the rotor circuit. ESD Field Kit Used to make work ESD safe Power Supply Used to supply power to the IED GUID-BFA755D6-9CE B4F9-4E4F525A554A v2 GUID-9C991E88-4B0E-4B1A-877A-F85E1ED192E1 v1 GUID-2613CBA7-B7D A3FA-01CB0DC14C40 v1 Configuration and monitoring tools Protection and control manager, PCM600, used to configure the IED set parameters monitor the IED and the system visualize and evaluate disturbance recordings SEMOD M v1 v2 M v2 Supervision and control of the power system via IEDs (HV/ Control package) Provides on request information from IEDs Collection of disturbances from IEDs Consists of standard library functions for easy application engineering of a station HMI Cable and dust cover The cable is used to connect a PC to the RJ45 port on the local human machine interface The dust cover protects the RJ45 port Labels Used to label the LEDs GUID-17E99276-BE53-4D03-A6D8-B926C5F81F8F v1 GUID-9F23A29B-E A87F-3D v1 SAM600-IO LHMI service kit The SAM600-IO LHMI service kit is a support tool for SAM600-IO during: Troubleshooting Commissioning Service Maintenance GUID-DA06ABEE-FAC7-4C7D-8912-A03FDDBEAA1D v2 GPS antenna Used with the GPS time synchronization module GTM (or GSM) SEMOD v2 Injection equipment hardware REX060, REX061, REX062 GUID-F6C11BE9-F5C A3F0-9437B715E48A v1 Is used to inject voltage and current signals to the generator or motor. 2. Mounting kits 19 rack mounting Use the 19" rack mounting kit for 6U housing to mount the IED in a standard rack. Combine the rack mounting kit with the side-by-side mounting kit to mount IEDs or an IED and a test switch module in the same rack position. M IP653-1 v1 v3 M v2 The 19" rack mounting kit is available in four designs, suitable for 1/4, 1/2, 3/4 or full width cases and consists of two rack ABB 3

4 flanges (1a) and (1b) with appropriate mounting details (2) for fastening to the case. 2 1a 1b 3 IEC en.vsd IEC V2 EN-US Figure 2. The flush mounting kit (release 2.1 and earlier) IEC en.vsd IEC V3 EN-US Figure 1. The rack mounting kit 4 1 Flush mounting for 670 and 650 series Use the flush mount kit for installation in a panel cut-out. M IP652-1 v2 M v2 The flush mounting kit for release 2.1 and earlier consists of four fasteners (2) with appropriate mounting details (4) and a sealing strip (5) for fastening to the IED (3). See Figure 2. From release 2.2 onwards, the flush mounting kit consists of two fasteners (2) with appropriate mounting details (4) and a sealing strip (5) for fastening to the IED (3). See Figure 3. The two fasteners are pre-assembled to the box. To receive IP54 class protection, an additional sealing (1) must be ordered with the IED. This sealing is factory mounted IEC =1=en.vsd IEC US Figure 3. The flush mounting kit (release 2.2 onwards) Wall mounting for 670 and 650 series Use the wall mounting kit to projection mount the IED on a wall. M IP651-1 v2 v1 M v1 The wall mounting kit consists of a mounting bar pair (4) and a IED bracket pair (6). Screws (2) and (5) and washers (1) for fastening of the terminal are included, but not wall fasteners (3). 4 ABB

5 IEC US Figure 4. The wall mounting kit 6 5 xx vsd 4 Wall mounting for SAM600-IO Use the wall mounting kit to projection mount the SAM600-IO on a wall, see figure 5. GUID-2C7B44A9-6E B20C-6EB36A9E0170 v1 6 5 The wall mounting kit consists of 8 washers (1), 8 screws (2), 2 mounting profiles (3), 6 nuts (4), 4 spacers (5) and 2 mounting angles (6). IEC US Figure 5. Wall mounting details IEC en.vsdx To order wall mounting kit, refer to section Mounting accessories. For more details on wall mounting, refer to Installation manual. Side-by-side mounting Use the side-by-side mounting kit to mount two IEDs or a IED and its corresponding test switch module next to each other. M IP649-1 v1 M v3 The side-by-side mounting kit consists of two mounting plates with appropriate mounting details (1 and 2). The side-by-side mounted units are mounted in a rack or cubicle using the appropriate kit; in this example, the rack mounting kit (3) is used IEC enOriginal.vsdx IEC V3 EN-US Figure 6. The side-by-side mounting kit ABB 5

6 Protection cover for rear area M v1 The protection cover for the rear area is a steel cover with a slot for cable entrance at the bottom part. SEMOD v2 Color matched (RAL7035) RHGS cases can be used to mount for example Combiflex modules together with 670 series. See section "Related documents" for reference to more detailed information about dimensions. Please observe that cases in referenced document has a different color. 4. Test switch module General The test switch module consists of a RHGS 6 case with a test switch, RTXP 24, and a two-seat Combiflex terminal base mounted. An optional DC-switch occupies one seat if selected. A side-by-side mounting kit is included. The side-by-side mounted units are mounted in a rack or cubicle using the appropriate kit, for example the rack mounting kit. M v4 IEC V2 EN-US IEC en.vsd Figure 7. Protection cover for rear area 3. RHGS cases All connections to the test switch module are made with Combiflex socket leads. Test contacts 1-24 of the test switch have 20 A Combiflex terminals. The signal contact of the test switch and the Combiflex terminal base have 10 A terminals. For more details about the Combitest system and Combiflex system see section "Related documents". RHGS Cases 6 ABB

7 1 Test switch 2 DC switch 1 3 Spare seat, can be used for Key switch 4 RHGS 6 case xx1mrk da_1.vsd IEC1MRK DA-1 US Figure 8. Example of a test switch module Test switch The test switch, RTXP 24, is used to make it possible to test a IED in a failsafe way. Inserting a test-plug handle into the test switch automatically makes all preparations for test in the proper sequence. Blocked trip circuits, shortcircuited CT s, opened voltage circuits makes the IED terminals available for secondary injection test. M v1 DC-switch The DC-switch is optional in the test switch module and are used to switch the DC-supply of the IED ON/OFF. The DC-switch is of one seat Combiflex type and needs a Combiflex terminal base to be mounted. M IP633-1 v1 M v1 5. Key switch for settings The key switch for lock-out of settings via the local human machine interface is used to prevent unwanted changes of settings. The switch locks the settings via a binary input. M v2 M v1 The key switch is of one seat Combiflex type. To install it, a case including a Combiflex terminal base is needed. One possibility is to install the key switch in the same case as the test switch. 6. Combiflex modules Auxiliary relays SEMOD v3 Auxiliary relays can be used together with the IED to provide functionality such as lock-out, lock-out reset or external contact re-enforcement When the contact rating of the IED is insufficient, it is recommended to use RXME 1 as a contact re-enforcement. The RXME 1 is then activated from an IED contact which is set up to be activated together with the IED contacts tripping the ABB 7

8 breaker. The contact of the RXME 1 is connected in parallel, to take over the breaker trip coil current. This gives an efficient solution and means no time delay at tripping. See figure 9. IED Breaker RXME 1 - T C + + A B C RXME 1 RXMD 1 xx ep IEC US Figure 11. RMXE 1 and RXMD 1 relays ANSI US Figure 9. RXME 1 used as a trip contact re-enforcement ANSI en.vsd When single pole tripping is used one RXME 1 is required per phase and of course per subsystem in redundant systems. Lock-out can be arranged with RXMD 1 remanence relay activated from binary outputs on IED and possible other protection relays required to activate lock-out, see figure 10. The contact of RXMD 1 is connected to open the closing circuit to the breaker closing coil. Another contact can be used to light-up a lamp push button to have indication of the lock-out and then reset with the push-button. It is recommended to avoid trip contact latching as this will mean problem for example with trip circuit supervision and further at failing breaker, mean that the trip coil is burnt and the trip coil DC supply is tripped. The most important is to prevent that the breaker is closed at persistent faults. Push button and selector switch The push button is available with or without pilot lamp and with one or two buttons. It is used to reset the lock-out relays when an external independent lock-out and lock-out indications is required. The push button unit can also be used as a local selector of Auto-Reclose operation when this is required to be done locally as well as through communication. SEMOD v2 The selector switch is available with two or three fixed positions and with different contact combinations. Selector switch can e.g. be used as Local/Remote selector or as a local selector of Auto-Reclose operation. See section "Related documents" for reference to more detailed information. IED + + IEC V2 EN-US Figure 10. External Close RXMD Lock-out using a RXMD 1 relay + Breaker C C xx en.vsd For ordering codes see section "Related documents" for reference to more detailed information. IEC US Figure 12. Push button and selector switch xx eps Supervision relay SEMOD v2 The relay RXEM1 can be used to detect for example loss of DC voltage supply or to detect open circuits. A typical application is continuous supervision of a circuit breaker trip circuit, including the breaker coil. See section "Related documents" for reference to more detailed information. 8 ABB

9 ANSI en.vsd 670/650 series and SAM600-IO ANSI 1MRK BUS G IEC US xx eps Figure 13. Supervision relay RXEM1 7. Connectors The connectors are used for analogue signals and binary inand output signals. M v3 Use the ferrules to connect two wires to the same terminal point of a connector of screw compression type. Note that 16 AWG is the maximum dimension allowed on these wires. An appropriate crimping tool is needed to apply the ferrule to the wires. Use the bridge connector to jumper terminal points in a connector. ANSI US Figure 15. Voltage connector, ring-lug type 2 1 Use ring-lugs to connect the wires to terminal points of a connector of ring-lug type. Select ring-lugs suitable to wiring dimension and size of fitting screw. IEC US Figure 16. xx vsd Ferrules and bridge connector M v4 1 Ferrules 2 Bridge connector 8. External resistor unit IEC V2 EN-US (xx eps) Figure 14. Voltage connector, screw compression type External resistor unit The high impedance resistor unit is used with the high impedance differential protection. It is available as one phase unit or three phase unit. SEMOD v2 ABB 9

10 IEC LITEN US Figure 17. High impedance resistor unit, three phase [6.97] [4.02] [1.48] [0.33] [18.31] [18.98] Dimension mm [inches] [0.79] [7.68] xx eps IEC V2 EN-US Figure 18. Dimension drawing of a one phase high impedance resistor unit 10 ABB

11 [7.50] [1.50] [10.47] [0.33] [18.31] [0.79] [7.68] [18.98] [inches] en eps IEC V2 EN-US Figure 19. Dimension drawing of a three phase high impedance resistor unit WARNING! USE EXTREME CAUTION! Dangerously high voltages might be present on this equipment, especially on the plate with resistors. Do any maintenance ONLY if the primary object protected with this equipment is deenergized. If required by national law or standard, enclose the plate with resistors with a protective cover or install in a separate box. 9. External current transformer unit Summation CT SEMOD v3 The external auxiliary summation current transformers are used for the cost effective summation type differential principle. IEC US Figure 20. Summation CT xx eps ABB 11

12 57 [2.24] 89 [3.5] 670/650 series and SAM600-IO ANSI 1MRK BUS G [19] IEC US Figure 21. Dimension mm [inches] Dimension drawing of summation current transformers xx vsd Distance between the center of the fixing holes is 465 mm [18.33]. WARNING! USE EXTREME CAUTION! Dangerously high voltages might be present on this equipment, especially on the plate with resistors. Do any maintenance ONLY if the primary object protected with this equipment is deenergized. If required by national law or standard, enclose the plate with transformers with a protective cover or install in a separate box. 10. Interface converter Galvanic interface G.703 resp G.703E1 The external galvanic data communication converter G.703/G. 703E1 makes an optical-to-galvanic conversion for connection M v5 to a multiplexer. These units are designed for 64 kbit/s resp 2Mbit/s operation. The converter is delivered with 19 rack mounting accessories. IEC US Figure 22. Galvanic Converter xx vsd 11. GPS antenna Introduction SEMOD v4 In order to receive GPS signals from the satellites orbiting the earth a GPS antenna with applicable cable must be used. 12 ABB

13 SEMOD v4 The antenna with a console for mounting on a horizontal or vertical flat surface or on an antenna mast. See figure 23 A suitable cable is available for ordering IEC V2 EN-US Figure 23. Antenna with console xx vsd SEMOD v5 where: 1 GPS antenna 2 TNC connector 3 Console, (2'6.7"x4'11') 4 Mounting holes about 1/5" 5 Tab for securing of antenna cable 6 Vertical mounting position 7 Horizontal mounting position Table 1. GPS Antenna and cable Function Max antenna cable attenuation Antenna cable impedance Lightning protection Antenna cable connector Accuracy Value GHz 50 ohm Must be provided externally SMA in receiver end TNC in antenna end +/-1μs ABB 13

14 12. Injection unit REX060 GUID-35437B83-47A9-4E2C-8D22-CCADC51BCC96 v1 Injection unit REX060 The injection unit REX060 is used to inject voltage and current signals to the generator or motor stator and rotor circuits. REX060 generates two square wave signals with different frequencies for injection into the stator and rotor circuits respectively. The response from the injected voltage and currents are then measured by the REX060 unit and amplified to a level suitable for the analog voltage inputs of IED. GUID-76627CA BB-ABDE-81A939D12BF4 v2 For local operation, the REX060 unit is provided with a control panel on the front. Local operation shall only be performed according to the operation regulations set up by the relevant operation authority of the plant. Mounting the injection unit REX060 GUID AC-6C84-44E6-9F AD0B7D5B v3 The injection unit REX060 case size is 6U, 1/2 x 19. REX060 can be rack, wall or flush mounted in the same way as the IED. For guidance, see instructions for rack mounting, wall mounting or flush mounting the IED in this manual. REX060 shall be mounted close to the IED. It is recommended that they are mounted in the same cubicle. REX060 Front panel IEC US Figure 24. REX060 front panel IEC en.vsd Rotor injection module RIM The RIM module is installed into the REX060 enclosure. The RIM module generates a square wave voltage signal for injection into the rotor circuit via a capacitor unit REX061 for isolation. The RIM module measures the voltage and current from the injected signal and the IED consecutively calculates the rotor to ground impedance. If the calculated impedance is lower than the preset value an ALARM and/or TRIP output is set. GUID-B2CA6C9E-2A24-483C-B9C2-47FFF2BBB283 v2 Stator injection module SIM The SIM module is installed into the REX060 enclosure. The SIM module generates a square wave voltage signal for injection into the stator circuit via the neutral point resistor or VT/NGT. The SIM module measures the voltage and current from the injected signal and the IED consecutively calculates the stator to ground impedance. If the calculated impedance is lower than the preset value an ALARM and/or TRIP output is set. GUID-CF2B E CB-2E86A01EA779 v2 14 ABB

15 13. Coupling capacitor unit REX061 Coupling capacitor unit REX061 REX061 isolates the injection circuit from the rotor exciter voltage. GUID-39A03C0F-44DC-47DD-9D7E-66C8292CD3A8 v1 The REX061 coupling capacitor unit grounding point and grounding brush of the rotor shaft should be properly interconnected. Coupling capacitor unit REX061 GUID-59726B2B CC1-8DEA-209F77CA5173 v5 X1 X2 IEC US Figure 25. Coupling capacitor unit REX061 IEC en.vsd ABB 15

16 223 [8,78] 38 [1,5] 255 [10] 235 [9,25] 199 [7,83] 670/650 series and SAM600-IO ANSI 1MRK BUS G 217 [8,54] 2 [0,079] 155 [6,1] Ø 5,5 [0,22] 84 [3,3] 84 [3,3] IEC en.vsd IEC V2 EN-US Figure 26. Measure and drilling plan REX061 shall be mounted close to the generator in order to limit the exposure of the field circuit. Alternatively it can be located in the excitation cubicle. The surface of REX061 unit may be temporarily very hot due to heat dissipation, up to about 50 C above the ambient temperature. It must be installed to get a open air convection and prevent contact with combustible material to the surface. 14. Shunt resistor unit REX062 Shunt resistor unit REX062 GUID-90D6AF74-D9AC-49B8-B2CA-8A94E58ADEA5 v1 REX062 is typically used when injection is done via a grounding transformer. 16 ABB

17 Shunt resistor unit REX062 GUID-184D F3-4F E9FDC95C3C41 v5 X1 IEC US Figure 27. Shunt resistor unit REX062 IEC en.vsd ABB 17

18 223 [8,78] 38 [1,5] 255 [10] 235 [9,25] 199 [7,83] 670/650 series and SAM600-IO ANSI 1MRK BUS G 217 [8,54] 2 [0,079] 155 [6,1] Ø 5,5 [0,22] 84 [3,3] 84 [3,3] IEC en.vsd IEC V2 EN-US Figure 28. REX062 measures and drilling plan REX062 shall be mounted close to the IED. It is recommended that REX060 and REX062 are mounted in the same cubicle as the IED. The surface of REX062 unit may be temporarily very hot due to heat dissipation, up to about 65 C above the ambient temperature. It must be installed to get a open air convection and prevent contact with combustible material to the surface. 15. Voltage injection unit RXTTE4 Voltage injection unit RXTTE4 The COMBIFLEX voltage injection unit RXTTE4 is used for rotor ground fault protection applications. The RXTTE 4 contains a voltage transformer with a primary winding for connection to 120 or 230 V, 50 or 60 Hz supply voltage. From the secondary GUID-B786414A-A36A-4F3B-B2D5-F1EF9488DA0E v1 winding of this internal voltage transformer approximately 40 V AC is injected via series capacitors and resistors into the rotor circuit. The injected voltage and current are fed to one voltage input and one current input on the IED. In order to mount injection unit RXTTE4 some COMBIFLEX accessories are required; RX4 terminal base, 10A and 20A 18 ABB

19 contact sockets and Crimping tool. See section "Related documents" for more detailed information. RXTTE Rotor ground fault protection can be integrated in the IED among all other protection functions typically required for generator protection. How this is achieved by using COMBIFLEX injection unit RXTTE4 is described in Instruction 1MRG R SEMOD v5 C ICT 1: V 50/60Hz IVT 44,7V V 50/60Hz V 321 IEC US Figure 29. IEC en.vsd Voltage injection unit RXTTE4 with its main internal components Table 2. Rotor ground fault protection (64R) based on General current and voltage protection (CVGAPC) and RXTTE4 Function Range or value For machines with: rated field voltage up to static exciter with rated supply voltage up to Supply voltage 120 or 230 V Trip ground fault resistance value Influence of harmonics in the DC field voltage 350 V DC 700 V 50/60 Hz 50/60 Hz Approx kω Negligible influence of 50 V, 150 Hz or 50 V, 300 Hz ABB 19

20 R1 R2 670/650 series and SAM600-IO ANSI 1MRK BUS G Table 2. Rotor ground fault protection (64R) based on General current and voltage protection (CVGAPC) and RXTTE4, continued Function Range or value Permitted leakage capacitance Permitted shaft grounding resistance Protective resistor (1 5) μf Maximum 200 Ω 220 Ω, 100 W, plate (the height is 6,2 inches (160 mm) and width 5,31 inches (135 mm)) External resistor for RXTTE4 GUID-53080A2D-E AD3D-8BD2C1E388D0 v2 The external resistor is used when either there is a need to minimize physical exposure of the field circuit or when high harmonic content of the total injection current can cause overheating of the built-in RXTTE4 resistor. The external resistor is delivered mounted on an insulated plate with overall dimensions; (the height is 6,2 inches (160 mm) and width 5,31 inches (135 mm)), suitable for wall mounting, see figure 30. It actually consists of two resistors (R1 and R2) which are on delivery connected in series. It is possible to order two different types of the external resistor. The first type (ordering number RK AD) has exactly the same ohmic value of 220Ω as the internal RXTTE4 resistor. It shall be used in cases where only physical exposure of the field circuit shall be limited. The second type (ordering number RK AB) has different ohmic value than internal RXTTE4 resistor. It shall be used in installations where current with high harmonic content is pushed back onto the RXTTE4 injection unit by the rotor circuit X1 IEC US Figure 30. IEC en.vsd External resistor mounted on a plate 16. ESD Field Kit ESD Field Kit GUID-3AEE96A2-E92B-4804-AD52-303B A v1 The ESD Field Kit provides a complete portable ESD safe workstation when working in the field. 20 ABB

21 M v2 The LIB 520 package provides the following main functions: User interface for the interaction with the control system and the controlled process Automatic supervision and control Alarm and event handling Data acquisition, calculating and reporting The high voltage software modules are a complement to the standard MicroSCADA software and provides an easy-to-build and easy-to-use HMI for supervision and control in MicroSCADA. The software is made for IEDs, and are providing a similar user interface as the LIB 500/510 standard library functions. 17. Power Supply IEC en.vsd Portable Power Supply The portable Power Supply provides the IED with power. This can be used at education or demonstration of the IED. Power Cable For use with the portable Power Supply. 18. Configuration and monitoring tools GUID-1E38BA0D-C36A-40D6-9BE1-1A6C3C20741C v1 GUID-6E83F62E-2E84-49D8-83B4-1EDA v1 M v3 See for more details about the tool, PC requirements etc. 21. User interface Introduction Local human-machine interface LHMI is not supported in SAM600-IO. However, the user interface functionality can be achieved using: Protection and Control IED Manager PCM600 SAM600-IO LHMI service kit GUID-B5F4628D-9A5F-4B5B-9B BA2337D v2 PCM600 M v3 Use PCM600 through all stages of a project, from engineering, configuring and parameter setting to testing, commissioning, documentation and maintenance. Use PCM600 to adjust the default configuration, or to make a new configuration. For more information about PCM600 visit There is no LHMI in SAM600-IO. The SAM600-IO LHMI service kit can be used to support commissioning, maintenance, testing and troubleshooting. References to LHMI in SAM600-IO user documentation should be read as SAM600-IO LHMI service kit. 19. Cable and dust cover Front communication M v2 The front connection cable is used to connect a PC to the RJ45 port on the local human machine interface. The cable is a standard crossed-over ethernet cable (RJ45 connectors). SAM600-IO LHMI service kit GUID-E29D D-4BB2-BEBE-C1FF7E919BDC v2 The SAM600-IO LHMI service kit should only be used as a temporary local human-machine interface (LHMI) to help the user to trouble shoot a device in field when status information in PCM600 is limited. It can also be used as a support tool during commissioning, maintenance or testing activities. Dust cover The dust cover is used to protect the RJ45 connector on the local human machine interface. GUID-EAC EE A77-821E00D9812F v1 20. MicroScada tools ABB 21

22 The SAM600-IO LHMI service kit contains the same physical LHMI panel as used in 670/650 series which includes the following elements: Display (LCD) Keypad LED indicators Communication port for PCM600 Serial cable for connection between the SAM600-IO LHMI service kit and the service port on the device. IEC en.vsdx IEC US Figure 31. SAM600-IO LHMI service kit 22 ABB

23 22. Ordering Mounting accessories M v5 Name For case size Quantity Article number Protection cover for rear area (release 2.1 and earlier): consisting of a steel cover with a slot for cable entrance at the bottom part, fixing screws and assembly instruction. Protection cover for rear area (release 2.2 onwards): consisting of a steel cover with a slot for cable entrance at the bottom part, fixing screws and assembly instruction. Protection cover for rear area (release 2.1 and earlier): consisting of a steel cover with a slot for cable entrance at the bottom part, fixing screws and assembly instruction. Protection cover for rear area (release 2.2 onwards): consisting of a steel cover with a slot for cable entrance at the bottom part, fixing screws and assembly instruction. Protection cover for rear area (release 2.1 and earlier): consisting of a steel cover with a slot for cable entrance at the bottom part, fixing screws and assembly instruction. Protection cover for rear area (release 2.2 onwards): consisting of a steel cover with a slot for cable entrance at the bottom part, fixing screws and assembly instruction. Protection cover for rear area (all releases): consisting of a steel cover with a slot for cable entrance at the bottom part, fixing screws and assembly instruction. 6U x 1/1 6U x 1/1 6U x 3/4 6U x 3/4 6U x 1/2 6U x 1/2 6U x 1/4 19 rack mounting kit: consisting of two mounting angles, fixing screws and assembly instruction. 6U x 1/1 1MRK AA 1MRK RA 1MRK AB 1MRK SA 1MRK AC 1MRK TA 1MRK AE 1MRK CA 6U x 3/4 1MRK BA 6U x 1/2 1MRK BB 6U x 1/4 1MRK BE Wall mounting kit for 670 and 650 series: consisting of 2 mounting angles, 2 mounting bars, fixing screws and assembly instruction. All sizes 6U 1MRK DA Wall mounting kit for SAM600-IO: consisting of 2 mounting angles, 2 mounting bars, fixing screws and assembly instruction. All sizes 6U 1MRK LA Flush mounting kit (670 and 650 release 2.1 and earlier): consisting of 4 fasteners, sealing strip, fixing screws and assembly instruction. All sizes 1MRK Y Flush mounting kit (670 and 650 release 2.1 onwards): consisting of 2 fasteners, sealing strip, fixing screws and assembly instruction. All sizes 1MRK PA Side-by-side mounting kit: consisting of 2 fixing plates, fixing screws and assembly instructions. All sizes 1MRK Z Note: All kits are complete including screws. ABB 23

24 RHGS Cases RHGS 6 with door, size 6Ux1/4, color RAL 7035 Quantity: SEMOD v2 1MRK AG RHGS 12 with door, size 6Ux1/2, color RAL 7035 Quantity: T RUTAKVADRA US 1MRK BH RHGS 30 with door, size 6Ux1/1, color RAL 7035 Quantity: T RUTAKVADRA US 1MRK BB T RUTAKVADRA US Test switch module M v2 IP521-1 v1 Note: Leads with 20 A Combiflex socket on one end and insulation stripped on the other end must be used to connect the test switch to the terminal. To connect the signal contact of the test switch and the DC switch, leads with 10 A Combiflex socket on one end must be used. Key switch for settings SEMOD v6 Key switch for lock-out of settings via LHMI Quantity: 1MRK A Note: To connect the key switch, leads with 10 A Combiflex socket on one end must be used. Combiflex modules SEMOD v2 Auxiliary relays Push button and selector switch Supervision relay Key switch for settings See related documents See related documents See related documents See related documents 24 ABB

25 Connectors Female connector 18 terminals of screw compression type, conductor area max 1 x 14 AWG or 2 x 18 AWG, 1 pc Quantity: 1MKC M v4 Female connector 18 terminals of spring compression type, conductor area max 1 x 16 AWG or 2 x 20 AWG, 1 pc Quantity: T RUTAKVADRA US 1MKC Ferrule For 2 x 16 AWG conductors in screw compression terminal, 1 pc Quantity: T RUTAKVADRA US 1MKC Bridge connector For 2 terminals in the current circuit, 1 pc Quantity: T RUTAKVADRA US 1MKC Bridge connector For 3 terminals, 1 pc Quantity: T RUTAKVADRA US 1MKC Bridge connector For 4 terminals, 1 pc Quantity: T RUTAKVADRA US 1MKC Female connector 18 terminals of ring-lug type, 1 pc Quantity: T RUTAKVADRA US 1KHL380110P0001 Female connector 5 terminals of ring-lug type, 1 pc Quantity: T RUTAKVADRA US 1KHL380109P0001 T RUTAKVADRA US External resistor unit SEMOD v8 High impedance resistor unit with resistor and voltage dependent resistor V, 1ph Quantity: RK MA High impedance resistor unit with resistor and voltage dependent resistor V, 3ph Quantity: RK MB High impedance resistor unit with resistor and voltage dependent resistor V, 1ph Quantity: RK CB High impedance resistor unit with resistor and voltage dependent resistor V, 3ph Quantity: RK DC External current transformer unit SEMOD v5 3 pcs SLCE 8 1 summation transformers on apparatus plate (2U high), 1/1 A Quantity: 1MRK EA 3 pcs SLCE 8 1 summation transformers on apparatus plate (2U high), 5/1 A Quantity: 1MRK FA 3 pcs SLCE 8 1 summation transformers on apparatus plate (2U high), 2/1 A Quantity: 1MRK GA ABB 25

26 Interface converter (for remote end data communication) M v9 External interface converter from C37.94 to G703 including 1U 19 rack mounting accessories Quantity: 1MRK AA External interface converter from C37.94 to G703.E1 including 1U 19 rack mounting accessories Quantity: 1MRK BA GPS antenna and mounting details GUID A3-593C EAE-198B9DA7F07B v1 GPS antenna, including mounting kits Quantity: 1MRK AA Cable for antenna, (Appx. 65 ft) Quantity: 1MRK AA Cable for antenna, (Appx. 131 ft) Quantity: 1MRK BA 26 ABB

27 Injection equipment GUID-3447C C-46B4-A36C-0B8B62D38E48 v7 Rule: If injection equipment is ordered, ROTIPHIZ or STTIPHIZ is required in the IED. Injection unit, REX060 Quantity: 1MRK AA The REX060 injection unit requires a connection to a VT across the generator neutral point grounding resistor. The VT must have a rating of at least 100 VA and a rated secondary winding voltage of up to 120 V. It must adhere to IEC :2011 section Rated Output Values and the standard values specified according to burden range II. Casing 1/2 x 19" rack casing Basic Backplane module (BPM) Basic Human machine interface HMI and logic module (HLM) Basic Injection modules Note: One of RIM and SIM have to be selected if REX060 is specified Rule: Stator injection module (SIM) is required if 100% stator ground fault protection, injection based (STTIPHIZ) is selected/active in REG670 Stator injection module (SIM) 1MRK AA If the generator is grounded via a primary resistor connected between the generator neutral point and ground, a VT is placed across the primary resistor. SIM is then connected to the secondary side of the VT. The VT must have a rating of at least 100 VA and a rated secondary winding voltage of up to 120 V. It must adhere to IEC :2011 section Rated Output Values and the standard values specified according to burden range II. Rotor injection module (RIM) 1MRK BA Power supply module Rule: One Power supply module must be specified Power supply module (PSM) VDC 1MRK AB VDC 1MRK BB Mounting details with IP40 of protection from the front 19" rack mounting kit 1MRK BB Wall mounting kit for terminal 1MRK DA Flush mounting kit for terminal 1MRK PA Extra IP54 mounting seal + flush mounting kit for terminal 1MRK NA Rule: REX061 requires REX060 and that Rotor injection module (RIM) is selected in REX060 and that Sensitive rotor ground fault protection, injection based (ROTIPHIZ) is selected/active in REG670. Coupling capacitor unit, REX061 Quantity: 1MRK AA Rule: REX062 requires REX060 and that Stator injection module (SIM) is selected in REX060 and that 100% stator ground fault protection, injection based (STTIPHIZ) is selected/active in REG670. ABB 27

28 Shunt resistor unit, REX062 Quantity: 1MRK AA External interface units for Rotor ground fault protection GUID-A7E E C2-20A26B0DE798 v4 Injection unit for Rotor ground fault protection (RXTTE 4) Quantity: 1MRK BA Protective resistor on plate. R1 = 100 Ώ, R2 = 120 Ώ Quantity: RK AD Protective resistor on plate. R1 = 560 Ώ, R2 = 560 Ώ Quantity: RK AB ESD Field kit GUID-701BA F-4FB6-89CB-E v1 ESD Field kit Quantity: 1MRK A Portable Power Supply Power Supply Unit Input voltage: V~, Hz Output voltage: 48 V DC Max. output current: 2,5 A Output power: 135 W max Switch frequency: 65 khz Quantity: GUID-8C65E7AF-31EF-4DF7-A9D6-1449C v2 1MRK FA Power Cable 2m Quantity: 1MRK EA Configuration and monitoring tools PCM600 SEMOD v5 See related documents IP516-1 v1 Labels SEMOD v3 LED Label special paper A4, 1 pc Quantity: 1MRK CA LED Label special paper Letter, 1 pc Quantity: 1MRK DA 28 ABB

29 Cable and dust cover GUID-413BF11A-F57C-40E4-89E3-84BFABFF63FD v1 Front connection cable Quantity: 1MRK CA Dust cover LHMI (RJ45) Quantity: 1MKC MicroScada tools M v2 LIB 520 See related documents SAM600-IO LHMI service kit GUID-AA273B49-34F4-4F54-8F22-F4A A6 v2 SAM600-IO LHMI service kit Quantity: 1MRK SA 23. Related documents M v4 Combiflex, connection and installation components Combitest Auxiliary, signalling and tripping relays Auxiliary relays Bistable relays Push button and selector switch Supervision relay LIB 520 PCM600 1MRK BEN 1MRK BEN 1MRK BEN 1MRK BEN 1MRK BEN 1MRK BEN 1MRK BEN 1MRK BEN 1MRS G ABB 29

30 30

31 ABB AB Grid Automation Products Västerås, Sweden Phone: +46 (0) abb.com/protection-control Copyright 2017 ABB. All rights reserved. Specifications subject to change without notice. 1MRK BUS

Relion 650 series. Accessories, 650 series IEDs versions 1.0 to 1.3, ANSI Product Guide

Relion 650 series. Accessories, 650 series IEDs versions 1.0 to 1.3, ANSI Product Guide Relion 650 series Accessories, 650 series IEDs versions 1.0 to 1.3, ANSI Product Guide Contents 1. Available accessories...3 2. Mounting kit for 3U... 3 3. Mounting kits for 6U...4 4. RHGS cases...6 5.

More information

Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles

Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles Page Revision: - Issued: December 00 Data subject to change without notice )HDWXUHV 0RXQWLQJNLWV 0RXQWLQJNLWV Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting

More information

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent

More information

Feeder protection relay SPAA 121 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase

More information

Residual overvoltage relay

Residual overvoltage relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Definite-time residual overvoltage earthfault protection and supervision Two independent operation stages, e.g. one

More information

Earth-fault Relay SPAJ 110 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral

More information

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent

More information

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault Issued: April 1999 Status: Updated Version: B/09.11.2001 Data subject to change without notice Features Sensitive restricted earth-fault protection stage for fast, selective earth-fault protection Sensitive

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

Relion 670 series. Busbar protection REB670 Installation and commissioning manual

Relion 670 series. Busbar protection REB670 Installation and commissioning manual Relion 670 series Busbar protection REB670 Document ID: 1MRK 505 180-UEN Issued: June 2010 Revision: C Product version: 1.1 Copyright 2010 ABB. All rights reserved Copyright This document and parts thereof

More information

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

Modular identification system

Modular identification system Modular identification system (xx00000675.tif).jpg Application To be able to locate a relay unit in a protective relay, the unit is identified with a unique item designation. Furthermore, the electrical

More information

Synchro-check relay. Application

Synchro-check relay. Application Issued: April 1999 Status: Updated Version: B/08.11.2001 Data subject to change without notice Features Two identical operation stages allowing the closing conditions of two separate circuit breakers to

More information

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series Substation Automation Products High impedance differential busbar protection REB650 Relion 650 series One IED for a wide range of high impedance differential protection applications ABB introduces a new,

More information

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice Issued: July 1998 Status: Revised Version: C/08.10.2003 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module , Inc. DMX512 Four Channel Dimmer and Switch module Input: 5 Amps @ 6-24 VDC Outputs: 5 Amps Maximum each, total 4 outputs 8 Amps Maximum. FRONT BACK USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION

More information

High impedance protection relay

High impedance protection relay High impedance protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features High impedance type differential current earth-fault protection, so called restricted

More information

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack Digital Lighting Systems, Inc. PD405DMX Four Channel Dimmer and Switch Packs DMX52 compatible PD405DMX24DC DMX52 4 x 5 Amps Dimmer Pack C UL US LISTED www.digitallighting.com Digital Lighting Systems,

More information

Feeder protection relay SPAA 341 C. Product Guide

Feeder protection relay SPAA 341 C. Product Guide Issued: April 1999 Status: Updated Version: D/07.03.2006 Data subject to change without notice Features Comprehensive numerical feeder protection relay consisting of two multi-function protection relay

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

High Impedance Protection Relay SPAE010, SPAE011. Product Guide SPAE010, SPAE011 SPAE010, SPAE011 1MRS750383-MBG Issued: April 1999 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features High impedance type differential current earth-fault

More information

DBK24. Isolated Digital Output Chassis. Overview

DBK24. Isolated Digital Output Chassis. Overview DBK24 Isolated Digital Output Chassis Overview 1 Power Requirements 2 Hardware Setup 2 Card Connection 2 Card Configuration 3 DaqBook and DaqBoard Connection 4 DaqBoard/2000 Series Board Connection 5 DaqBook

More information

DELOMATIC - MULTI-FUNCTION SYSTEM PART 2 INSTALLATION INSTRUCTION

DELOMATIC - MULTI-FUNCTION SYSTEM PART 2 INSTALLATION INSTRUCTION CONTENTS: 25.0...2 25.1 SYSTEM INSTALLATION...2 25.1.1 Before installing the DELOMATIC system...2 25.1.2 Installing the DGU...3 25.1.3 Installing the CP...4 25.1.4 Connecting the power supply...6 25.1.5

More information

Feeder protection relay

Feeder protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Comprehensive numerical feeder protection relay consisting of two multi-function protection relay modules and a flexible

More information

- Optional separate COMBITEST test switch for reliable and safe testing 1MRK BEN

- Optional separate COMBITEST test switch for reliable and safe testing 1MRK BEN 5' Page 1 Revision B Issued: November 2003 Data subject to change without notice Three-Phase Terminal Three One-Phase Terminals )HDWXUHV High speed general differential protection. Minimal operating time

More information

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-6100 PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 2-C-050818 Copyright 2018 Littelfuse All rights reserved. Document

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Relion 670 series. Busbar protection REB670 ANSI Installation and commissioning manual

Relion 670 series. Busbar protection REB670 ANSI Installation and commissioning manual Relion 670 series Busbar protection REB670 ANSI Document ID: 1MRK505210-UUS Issued: February 2015 Revision: D Product version: 1.2 Copyright 2012 ABB. All rights reserved Copyright This document and parts

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018 September 2018 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664,

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Line differential protection RED670 Relion 670 series Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,

More information

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series Substation Automation Products Transformer protection RET670/650 Relion 670 and 650 series For reliable protection and control of all types of power transformers and reactors The RET670/650 IEDs (Intelligent

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Accessories / 7XV5662

Accessories / 7XV5662 Accessories / XV Communication Converter XV-0AA00/GG for X. / RS / G.0. *) Fig. / Communication converter for X./ RS and G.0. The communication converter CC-XG for coupling to a communication network is

More information

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A) IRI1-ES Sensitive Earth Fault Current Relay Manual IRI1-ES (Revision A) Woodward Manual IRI1-ES GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

Relion 650 series. 650 series 2.1 IEC Installation manual

Relion 650 series. 650 series 2.1 IEC Installation manual Relion 650 series 650 series 2.1 IEC Document ID: 1MRK 514 025-UEN Issued: January 2016 Revision: - Product version: 2.1 Copyright 2016 ABB. All rights reserved Copyright This document and parts thereof

More information

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756901 A Slide 1 Content RET615 Technical Presentation highlights May

More information

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series Substation Automation Products Line distance protection REL670/650 Relion 670 and 650 series For maximum reliability of your power system REL670 and REL650 line distance protection IEDs (Intelligent Electronic

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series Substation Automation Products Bay control REC670/650 Relion 670 and 650 series For optimized control and reliable operation of your switchyard The REC670 and REC650 Bay control IEDs (Intelligent Electronic

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin g GE Consumer & Industrial Multilin HID High Impedance Differential Module Instruction manual GEK-113064 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue L6E 1B3 Markham, ON -CANADA T (905) 294

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

670 series Version 2.2 IEC Installation manual R E L I O N 670 SERIES

670 series Version 2.2 IEC Installation manual R E L I O N 670 SERIES 670 series Version 2.2 IEC R E L I O N 670 SERIES Document ID: 1MRK 514 026-UEN Issued: October 2018 Revision: E Product version: 2.2 Copyright 2017 ABB. All rights reserved Copyright This document and

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

Product data sheet accessories control and regulation Accessories AIRWIN

Product data sheet accessories control and regulation Accessories AIRWIN Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

P2-04DA Analog Output. Removable Terminal Block Specifications

P2-04DA Analog Output. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

General Specifications. P2-8AD4DA-2 Analog Input/Output

General Specifications. P2-8AD4DA-2 Analog Input/Output General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation 1.95W º to 6ºC (32º to 14ºF)

More information

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation ABB Oy Distribution Automation July 1, 2009 1MRS756504 B Slide 1 Contents RED615 Technical Presentation

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

DRTS 66 can test all the following relays

DRTS 66 can test all the following relays Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs

More information

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay IE ON RESET.5 X1 t IE X1.6%.2.4.8 1.6 X1.1s.2.4.8 1.6 X2 OFF ON S1 S2 IRI1-ES IRI1-ES C&S Electric Limited (Protection & Control Division) Contents

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes System Freelance 800F AC 700F Module Description Data Sheet Central Processing Unit PM 783F Detailed data of the CPU (PM 783F) CPU Processor Program memory (Battery backed up) Internal memory Typical cycle

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

A P P L I C A T I O N

A P P L I C A T I O N Circuit Breaker timing test set 16 timing channels Motion and speed analyzer Built-in 200 A microohmmeter Up to 4 trip/close coils control Static and dynamic contact resistance measurement Suitable for

More information

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A AUTOMATION MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A GRID Note: The technical manual for this device gives instructions for its installation, commissioning,

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136

Company Directive ENGINEERING SPECIFICATION EE SPEC: 136 Company Directive ENGINEERING SPECIFICATION EE SPEC: 136 Ancillary Electrical Equipment for Use in Conjunction with Switchgear and Protection/Control Panels NOTE: The current version of this document is

More information

Protection Relay RE_ 610. Installation Manual

Protection Relay RE_ 610. Installation Manual RE_ 0 MRS-MUM Issued:..00 Version: E/0..00 RE_ 0 Contents Copyrights.... Introduction........ This manual........ Use of symbols........... Intended audience........ Product documentation........... Document

More information

ADAPTERS AMPLIFIERS ATTENUATORS DIAL ADAPTERS GONG ATTACHMENTS MAGNETIC AMPLIFIERS TRANMITTER ARMS TRANSMITTER ATTACHMENTS

ADAPTERS AMPLIFIERS ATTENUATORS DIAL ADAPTERS GONG ATTACHMENTS MAGNETIC AMPLIFIERS TRANMITTER ARMS TRANSMITTER ATTACHMENTS Table of Contents A... 2 B... 2 C... 3 D... 4 E... 4 F... 4 G... 4 H... 4 I... 5 J... 5 K... 5 L... 6 M... 6 N... 6 O... 7 P... 7 R... 7 S... 8 T... 9 U... 10 V... 10 W... 10 A ADAPTERS AMPLIFIERS ATTENUATORS

More information

P2-04AD Analog Input. Removable Terminal Block Specifications

P2-04AD Analog Input. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

Content REF615 Technical Presentation

Content REF615 Technical Presentation Distribution Automation Relion 615 series Feeder Protection and Control Ver. 2.0 Technical Presentation March 30, 2010 1MRS756407 E Slide 1 Content Technical Presentation highlights March 30, 2010 Slide

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

Site Preparation CHAPTER

Site Preparation CHAPTER CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option For Emotron VFX/FDU 2.0 AC drive Emotron VFXR/FDUL Emotron FlowDrive Emotron TSA softstarter Instruction Manual English PTC/PT100 board 2.0 Option For Emotron VFX/FDU 2.0 AC

More information

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments CPU module for small and medium sized wind turbines Safe operation in harsh environments Maintenance free - no fans and no batteries that need replacement Advanced event based data logging and storage

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3. Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200

More information

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.

THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. D R T S 6 6 THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. www.isatest.com DRTS 66 The new generation of advanced test equipments for relays,

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer

More information

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis. A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist

More information

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks GUIDEFORM SPECIFICATION Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks The freely configurable relay is intended for protection, control, measurement

More information