Harpagon/Harpagon SRP 160 Flow meter systems User s Guide

Size: px
Start display at page:

Download "Harpagon/Harpagon SRP 160 Flow meter systems User s Guide"

Transcription

1 Harpagon/Harpagon SRP 160 Flow meter systems User s Guide November 2004 Harpagon Version 6 Auper Electronic Controls Inc

2 Contents 1 General information... 3 Power Source... 4 Uninterruptable Power Supply (UPS)... 4 Customer Support... 4 Pre-installation considerations Using the computer Not using the computer Harpagon network Selecting the serial port... 5 FLOW METERS... 5 Pre-Mix... 6 Post-Mix... 6 Installing the tailpieces... 6 Installation... 7 Draft beer and Wine... 7 Teed beer lines:... 7 Soft drink... 8 Carbonated water:... 8 Syrups:... 8 Connecting the flow meters to serial collector... 9 Connecting the flow meter collector to the Harpagon system... 9 Testing the connections Calibration Verifying your calibration values Programming modes (Harpagon version) Programming modes SRP 160 version OPERATION (Harpagon) Key is in the Run position Operation SRP 160 version Using Auto shift and Auto print (SRP 160 only) Power Fail counter Connecting the Harpagon system to your computer Rs-422 cable Networking Auper systems Rs-422 Hub Network Cables Network cable terminations Cable inversion: The Harpagon Ver 6 option

3 2 TROUBLE SHOOTING Flowmeter not registering as being connected (16 pulse mode) Flowmeter not registering impulses Harpagon not responding Number of unit registered seems to be off...18 Harpagon does not communicate with computer TTL outputs Trouble shooting foamy draft beer Does the serving temperature correspond to the brewer s norms? Is the flow rate between 2.5 and 3.5 l/min (Approx 2 oz/sec)? Is the beer flat or over carbonated? Non-refrigerated kegs (Europe) Draft beer control The draft beer system Controlling sales Inventory control Reconciling sales using flow meters Tips WARRANTY

4 Harpagon and Harpagon SRP When unpacking your Harpagon system, you should find the following components: Part No Description Harpagon flow metering system Serial flow meter collector ft Network cable volts or 220 volts to 12 Volts AC 20 VA wall mount transformer pin to 9 pin null modem serial cable (10 ft) Draft Manager Ver 1.1 software General information The Harpagon is a micro-controller designed for beverage flow metering. Its purpose is to register the electronic impulses generated by the Auper flow meters when liquid flows through the flow meters. Each Harpagon can monitor up to 16 different beverage lines. Up to 100 Harpagon systems can be networked to form a very large flow metering system using the Auper 8 inputs Rs-422 stackable hubs. Counters can be read directly from the liquid crystal display. However, the real power of the Harpagon is found when using the new Draft Manager software. Harpagon in version SRP 160 includes the time and date and 3 different set of counters to print reports directly to a serial printer fo up to three shifts per day. Up to 16 flow meters per system Up to 100 Harpagon systems can be networked and operated from Draft Manager Universel unit mode (oz, litres, glasses, gallons, etc..) Backlight display Reset key switch Powered by a 12 Volts AC wall mount transformer Power fail memory back up 3

5 4 Power Source The Harpagon is powered by a 12 20VA power source. Each system must have its own separate power source. It is recommended to use a clean electrical outlet. Uninterruptable Power Supply (UPS) If you feel that your Harpagon may be exposed to extreme electrical power fluctuations or spikes, you may want to use a UPS system. UPS stands for Uninterruptable Power Supply. The UPS is equipped with proper power surge protection and a battery back up. It could be used for other equipment as well. In case of power failure, your Harpagon system will remain ON for a few hours on battery power. UPS systems are available at office supply stores. Customer Support AUPER provides telephone support for all its products, available Monday to Friday from 9 am to 5 pm (Eastern standard time), except on Holidays. If you have any questions regarding your new Harpagon, don t hesitate to call the AUPER technical support help desk at Pre-installation considerations 1. Using the computer If you are using the Draft Manager software supplied with your Harpagon, you can install your Harpagon system(s) anywhere as long as you have a serial cable linking the computer to it. The flow meters cables can be connected directly to the Harpagon s serial flow meter collector outside the cooler. A straight network cable will link the flow meter collector to the Harpagon. A RS-232 or Rs-422 cable will link the Harpagon to the computer. 2. Not using the computer If you wish to read the meters directly from the Harpagon display, then select a convenient location easily accessible but that retains a certain level of security. The power supply cord and the power source should be well secured to insure they couldn t be tampered with. The manager s office is often selected. This set up will require that you install multiple pair cables between the cooler (or stock room) and the Harpagon system to connect your flow meters to it. 4

6 5 3. Harpagon network If you plan on connecting several Harpagon systems to your computer and use the Draft Manager software, you should read the network section of this manual before you start your installation. The Auper Eclipse Hv 100 liquor dispenser can also be installed on the same network of Auper systems. 4. Selecting the serial port If several Harpagon systems are networked using the Auper hub, or if the distance between the system and the computer exceeds 100 feet, the RS-422 port must be selected. Select the serial port using the switch on the back panel. FLOW METERS Each flow meter kit includes a pre-assembled flow meter with the specified tailpiece size, a plastic wall bracket, screws, hose clamps and 25 ft of flow meter cable. Use stainless steel tailpieces for carbonated water, syrups and wine. Use chrome plated tailpieces for draft beer. Hand tighten the plastic nuts at room temperature. When the washers are cold, sealing the adaptors may be difficult. Grab the two plastic nuts and twist. The amount of pressure required to seal the tailpieces on the washers is directly proportional to the pressure of the gas used to push the liquid. If the gas pressure is high, you will need to tighten the nuts more firmly. DO NOT GRAB THE FLOW METER BY THE CENTER TO TIGHTEN THE ADAPTORS (you could damage the coil). Using a sharp utility knife cut the tubing where the flow meter will be installed. Leave enough line to be able to move the kegs easily. Caution: Install the flow meter at least 30 cm (12 inches) from transformers, blowing fans or motors. These devices emit a magnetic field (60Hz), which can be picked up by the flow meter. If the counter moves without any liquid being dispensed, move the flow meter away from the source. 5

7 6 Pre-Mix Whether it is wine, juice, or soft drink, if it s ready to serve it s Pre-Mix. As with draft beer, one flow meter per line will be necessary. Post-Mix 1. Measuring carbonated water: The ratio of the mixture (or Brix ) is usually the same for all the syrups (5:1). By installing the flow meter in the carbonated water (soda) line, the flow meter system will register the total amount of soft drink served through the dispenser. 2. Measuring syrups: If you want to know the quantity of each flavor served, you will need to install a flow meter on each of the syrup lines. It is necessary to use the flow meter model number (slower flow rate). Installing the tailpieces Remove the lexan nut. Select the tailpieces corresponding to the internal diameter of the tubing. Insert the tailpiece in the lexan nut first and then the washer. Screw the lexan nut back on. Do not tighten. Repeat on the other side. Hold both lexan nut and tighten the nuts to seal. DO NOT HOLD THE FLOW METER BY THE MIDDLE TO TIGHTEN THE LEXAN NUTS. 6

8 Installation 7 Draft beer and Wine If empty keg detectors (FOBs) are present, install the flow meter immediatly after as it will prevent the flow meter from ever being in contact with air or foam. Teed beer lines: If one keg supplies more than one beer lines using a tee, you must install check valves before each flow meter. The check valve prevent the liquid from moving back in the line when the pressure drops when the faucets are pulled open. Remove the keg coupler and open the faucet to decompress the product line. Cut the line where you will insert the flow meter. Slide a hose clamp on each side, check the flow direction and insert the flow meter. Tighten both clamps and secure your flow meter to the wall using the bracket. Re-install the keg coupler. Check for leaks. The insertion of the flow meter has created an air pocket in the beverage line. You must pour enough beer to evacuate the air pocket before proceeding with the calibration of the system. Leave the faucet open until the air pocket has passed. Let the beer rest for a few minutes. 7

9 8 Soft drink Carbonated water: Shut the water, CO2 and carbonator pump off. Depressurize the carbonated water line. Install stainless steel tailpieces corresponding to the internal diameter of the line and the washers. Using a sharp utility knife cut the tubing where the flow meter will be installed. Slide a hose clamp on each side, check the flow direction and insert the flow meter. Tighten both clamps and secure your flow meter to the wall using the bracket. Turn the water, CO2 and the pump back on. Pour enough carbonated water to bleed the line of any trapped air pockets. Check for leaks. Syrups: Disconnect the power to the pumps or shut off the gas pressure to the pumps to cut the pressure within the feed lines. Depressurize each flavor. Slide a hose clamp on each side, check the flow direction and insert the flow meter. Pressurize the feed lines and check for leaks. 8

10 Connecting the flow meters to serial collector 9 Pass your flow meter cables out of the cooler to where the flow meter collector is installed. Secure your cables with cable ties and cut them near the monitor system. Strip 1/2 inch (2 cm) of the insulation off the wires. Press the lower sides of the cover to remove it. Screw the turbine collector to the outside wall of the cooler out of reach of normal traffic. Each terminal is identified on the circuit board T1 to T16. Use a small flat screw driver and unscrew the terminals. Insert the wires. Screw down the to close the contact. Make sure the contact is closed on the copper wire to guarantee a secured and solid connection. Secure all your wires with cable ties. Connecting the flow meter collector to the Harpagon system Disconnect the Harpagon system before connecting the flow meter collector. Connect the Cat 5 network cable between the flow meter collector and the input connector of the Harpagon system. The Cat 5 network cable can be very long up to 1000 M. Connect the power supply wires to the VA power supply. Make sure the power supply is not easily accessible or that it cannot be accidentally disconnected. Plug the transformer in the electrical outlet. Inexpensive power bars should be avoided. 9

11 Testing the connections 10 Turn the key to Program to enter the Impulse mode of the Harpagon The impulse mode is used to verify that all the flow meters are connected properly to the Harpagon. From left to right, 16 dots represent lines 1 to 16. When a flow meter is connected to a line, the corresponding dot is up. If no flow meter is connected to a line, the corresponding dot is down. When a flow meter detects liquid flowing though it, the corresponding dot will alternate up and down. If a flow meter is installed backward, the corresponding dot will be up but will not alternate when product is flowing. Calibration The calibration procedure insures the accuracy of the measurements of the flow meter system. Each flow meter must be calibrated with the product it is measuring. The flow meter should be re-calibrated if the product is changed or if the dispensing flow rate was changed by a factor of 30 % or more. Calibrating an Auper flow meter system requires you to pour a measured amount of product at each faucet into a graduated cylinder. In the calibration mode, the system calculates how much liquid flows through each flow meter for one turbine impulse. During the calibration procedure all 16 lines are calibrated at the same time. This feature prevents you from having to go back and forth to the Harpagon to set the calibration values. As soon as the system is put in the calibration mode, the amount of liquid dispensed at each faucet is used to calibrate the metering system. If liquid is dispensed on a line that you did not intend to calibrate, the calibration of that flow meter will be changed. Only the lines that have detected liquid flowing will calibrate. When you are ready to calibrate your meters, tell everyone not to use any of the beverage lines for the duration of the calibration procedure to prevent unwanted re-calibrations. ***To accelerate the calibration, spraying a little WD40 inside the graduated before filling it with beer will eliminate the foam rapidly. 10

12 Steps: 11 Press the mode button once: The display shows CAL. WITH 20 oz. Press the Set button to alternate between CAL. WITH 1 UNIT and CAL. WITH 20 oz. The Harpagon can be programmed to measure ounces, liters, gallons, glasses, etc... To calibrate to count ounces select the CAL. WITH 20 oz For all other measuring units select the CAL. WITH 1 UNIT When the calibration value is selected, press the Mode button once. The display shows C à You have now entered the calibration mode. Even though only one line is showed on the display, all sixteen lines are in calibration mode. If you selected USE 20 to calibrate to measure ounces: Pour and measure exactly 20 ounces of product at each faucet using a graduated cylinder. If you selected USE 1, pour exactly one unit (1 Liter, 1 gallon, 1 glass) at each faucet using a graduated cylinder. The display will show the corresponding flow meter pulses on line 1. Press the up and down button to change the line number displayed. For example: C Press the Set button to calibrate all 16 lines. The display will show the resulting value of the calculation (For ex: 20/300 = or 1/502 = ) C If you are not satisfied with the measure and wish to re-calibrate either one, or all lines, remain in this mode after pressing the front panel button to set the calibration values. Start again on the lines you want to re-calibrate. Lines, on which the pulse counter remained at zero indicating no product was served, will retain their old calibration. Make sure that no one uses the dispenser while you calibrate to avoid unwanted recalibrations. ] 11

13 Verifying your calibration values 12 A Auper flow meter generally used for domestic draft beer, should generates approximately 15 pulses per ounce. If you calibrate to measure ounces, 20 ounces times 15 = 300 pulses. Since the Harpagon divides 20 by the number of pulses measured, the resulting value after pressing the Set button should be in the area of Everything the Harpagon measures can be verified mathematically. For example: A flow meter generates 289 pulses for 20 ounces: 20/289 = (or pulses per ounce) The same flow meter will generate for one liter: 1 liter = 35.2 imperial ounces = 508 pulses with a resulting calibration value of 1/508 = liter = 33.8 US ounces = 488 pulses with a resulting calibration value of 1/488 = You can always scroll through the different lines to look at the pulse count or the resulting calibration values on each line to make sure they are in the expected range. Programming modes (Harpagon version) Press mode once: CLR 1? This mode allows you to reset the displayed counter to zero by pressing the Set button. To continue without resetting the counter press Mode. To clear the counters individually, use the up and down buttons to select the line number and press the S/R button the reset the displayed counter. The counters can be cleared all at once using the key in the normal operation mode (see next section). Press «mode» again. The SYSTEM DISABLED mode may be used when beverage lines are being cleaned or when priming the lines.. This mode is used to disable the system from counting. As long as the display shows system disabled, the counters are not registering. Press Mode or turn the key to Run to exit this mode and activate the counters. Press «mode» again. In CLR PWF? :... press the Set button to reset the power failure counter to zero. Each time the Harpagon is disconnected, or there is a power failure, the PWF counter will register one count. Press «mode» again. SYSTEM NUMBER 00. Use the Up and Down arrows to select the Harpagon number. This number will identify the system for the software. When several Harpagon systems are networked to the same computer, each system must be given a different number starting with 00 up to 99. Turn the key back to Run to exit the program mode. 12

14 Programming modes SRP 160 version 13 Press mode once: CLR 1? This mode allows you to reset the displayed counter to zero by pressing the Set button. To continue without resetting the counter press Mode. To clear the counters individually, use the up and down buttons to select the line number and press the S/R button the reset the displayed counter. The counters can be cleared all at once using the key in the normal operation mode (see next section). Press «mode» again. The SYSTEM DISABLED mode may be used when beverage lines are being cleaned or when priming the lines.. This mode is used to disable the system from counting. As long as the display shows system disabled, the counters are not registering. Press Mode or turn the key to Run to exit this mode and activate the counters. Press «mode» again. In CLR PWF? :... press the Set button to reset the power failure counter to zero. Each time the Harpagon is disconnected, or there is a power failure, the PWF counter will register one count. Press «mode» again. SYSTEM NUMBER 00. Use the Up and Down arrows to select the Harpagon number. This number will identify the system for the software. When several Harpagon systems are networked to the same computer, each system must be given a different number starting with 00 up to 99. Press Mode again. To change the date: press UP to change the month, press down to change the day and press set to change the year. Press mode again: To change time: Press up to change the hour, press down to change the minutes and press set to reset the seconds to zero. Press mode again: Nb of shifts = 1. Use the Up and down buttons to select the number of shifys per day. Up to three shifts can be selected. A separate set of counters will be used for each shift. All shifts are cleared when the manager restes the counters. Press mode again: To set the automatic shift change times: press up to select between shifts 1, 2 or 3. Press down to change the hour and press ste to change the minutes. Press mode again to come go to the first mode (impulse mode). Turn the key back to Run to exit the program mode. 13

15 OPERATION (Harpagon) 14 In normal operation, the key is used to validate the presence of the manager when programming the system, resetting the counters or putting the system in the system disabled mode for line cleaning. Key is in the Run position. The display shows the number of ounces, liters or units dispensed per line according to the unit type selected when you calibrated the system. Pressing the Up and down arrows will change the line number displayed. Pressing «Set» allows you to view the PWF counter. Pressing «mode» will take you to the master reset mode. To clear the 16 counters, turn the key to Prog and then back to Run. Operation SRP 160 version The key is in Run position. Before you press the Mode button, the display shows the amount of product dispensed. Press the UP and Down buttons to view each line. Press S/R to view the Power fail counter. Press Mode once to see the time and date. Press mode again: Manual/Auto shifting Turn the key to Prog. Press Set to select between Auto or Manual shifting. Press Mode again: Manual/Auto printing Turn the key to prog to select between Auto or Manual printing. Auto print is available only if Auto shifting has been selected. Press mode again: Current shift. Turn the key to Prog. Use the Up and Down buttons to select another shift. Press Mode again: SHF Display the total amount of product dispensed per shift. Press the Up and Down buttons to change shift. Press mode again: Print report? Press Set to print to serial printer only. CLR All Lines? Turn the key to Prog and back to Run to reset all counters to zero. Using Auto shift and Auto print (SRP 160 only) When set to manual, the manager selects the Shift manually. When set to Auto shift, the SRP 160 will change the counter bank for each shift at the times set (1,2 or 3). If Auto print is selected, the system will print a report automatically at the end of each shift. 14

16 15 Power Fail counter The power fail counter counts the number of times the power was lost. That could mean there was a power failure or that the system was disconnected. When the system is installed in a location where power failures are frequent, installing a UPS (un-interruptable power supply) is a good idea. The battery back up in the UPS should supply enough power to last a few hours. UPS systems can be purchased at electronic stores or office supply stores. Connecting the Harpagon system to your computer The Harpagon is supplied with a 10 ft Rs-232 null modem cable ready to be connected to your IBM compatible PC. The Rs-232 connector on your PC is a 9-pin male connector as shown on the picture. Most PCs have two connectors identified as COM 1 and COM 2. The COM port on your computer must be operational and properly configured in Windows in order for the computer to communicate with the Harpagon system. Rs-232 cable pin out Rs-422 cable DB9F DB9F Solder pins 7 to 8 and 4 to 6 on both sides. If the distance between your Harpagon and the computer is greater than 100 feet (30 meters) or if you connect more than one Harpagon or other Auper system to the same computer, you must use Rs-422 cables that are terminated by modular jacks (telephone connectors). The Rs-422 protocol is not compatible with your computer. You must install an Rs-422/Rs- 232 converter at the computer. You can order a Rs-422 cable pre-tested from the factory. 15

17 Networking Auper systems 16 Rs-422 Hub Both the Auper Harpagon flow meter system and the Eclipse Hv100 liquor dispenser can be interfaced to your computer. Auper makes two different software: Draft Manager for the Harpagon and Liquor Manager for the Eclipse Hv 100. Both software can share the same serial port on your computer, which provides for the ability to network the systems together. Up to 100 Auper systems can be networked to one computer using the Auper 8 input Rs-422 stackable hub (part No: ). You can connect two systems that are within 10 meters from each other using a modular splitter. A splitter can be connected directly to the rs-422/rs-232 converter. For larger networks, a splitter can be connected to a hub. Using the hub is mandatory if you plan to connect more than two systems together. All network transmissions use the Rs-422 protocol. At the computer end of the network, the Auper Rs-422 to Rs-232 converter (part No: ) is necessary to convert the signals coming from the Rs-422 network into the Rs-232 format compatible with your computer s 9 pins serial port. Order at least one Rs-422 hub and Rs-422/Rs-232 converter kit (Part No ). Additional hubs can be ordered separately (Part No ) The output of one hub can be connected to any one of the 8 inputs of another hub to enlarge your network. Any number of hubs can be used this way. Up to 1000 meters can separate two Auper devices using the Rs-422 protocol. Each Auper system on the network must be set to use the Rs-422 port as explained in their corresponding user manuals. Network Cables Two types of cables are involved when planning the installation of a Rs-422 network: Modular cables (like telephone cables) to connect the systems to the network. Cat 5 network cables are used to link each bar or storage rooms to the office where the computer with the software is. 16

18 Network cable terminations 17 Use Cat 5 jacks and wall plates to terminate your Cat 5 cable. Follow the standard color codes for straight network cables. Use the punch down tool to secure each connection. The Rj-11 modular jack of the Auper Rs-422 cables fits in the middle of the Cat 5 jack. Cable inversion: The Rs-422 connector has 4 wires: Tx+, Tx-, Rx-, Rx+ The data transmitted (Tx) by one machine must be received (Rx) by the other A Tx pin cannot receive and vice-versa. The Pin 1 Tx + of one machine must end up in Pin 4 Rx + of the other. The Pin 2 Tx - of one machine must end up in Pin 3 Rx - of the other. Modular cable Part No is inverted as follows Yellow wire Tx+ to black wire Rx+ Red wire Tx- to green wire Rx- Green wire Rx- to red wire Tx- Black wire Rx+ to yellow wire Rx+ Two inverted cables installed in series will cancel the inversion and communication cannot happen. When using a Cat 5 network cable, you will use two modular cables. The second one must be straight to keep the inversion (part No: ) The Harpagon Ver 6 option With the Harpagon Ver. 6.0 you have the option of using a Cat 5 network cable to connect your flow meter collector to your Harpagon system. One network cable per Harpagon flow meter collector is necessary You can mount the flow meter collectors inside or near the beer kegs storage room and install the Harpagon systems in the office near the Rs-422 hub. The connections between the Harpagon sustems and the hub will be achieved using the inverted modular cables (Part: ) or Use a Rs-422 splitter to connect two Harpagon systems using inverted modular cables and run one Cat 5 cable between the storage room and the office where the hub is. 17

19 18 If you have more than two Harpagon systems, you will need to use a Hub at the storage room as well. Only one network cable can link all Harpagon to the office One hub should be installed at the location where the Harpagon systems are installed to link them all together and come out of the hub with only one cable. The outlet of the hub is then connected to a Cat 5 cable going to the office. TROUBLE SHOOTING Flowmeter not registering as being connected (16 pulse mode) Check connections on turbine collector (loose) Check connection at the flow meter Check wiring (broken cable) Switch the flow meter with one registering properly to check wiring. Bring a working turbine directly to the turbine collector and blow to check if the pulses register. Flowmeter not registering impulses. Check flow direction. Has the beer line been cleaned in a long time? Dismantle turbine and rinse in hot water until it spins freely. Is the flow rate approximately 2 oz/second? Select a flow meter if the flow rate is slower. Harpagon not responding Disconnect power, wait 5 seconds and plug it back in. Check PWF counter for excessive number of power failures. Call authorized factory technician. Number of unit registered seems to be off. Check calibration by serving product into a graduated cylinder. Verify dispenser for excessive foaming problem and increased wastage. Check glass size by pouring content into a graduated cylinder. Has the brand dispensed on this line been changed without re-calibration? 18

20 Harpagon does not communicate with computer. 19 Check Com port selection (Rs232 or Rs422) on Harpagon circuit. Check Com port selection on computer. Do you have the corresponding system number in the software? Are you connected to a 9 or 25-pin male connector on the computer side? (If no, it is not a Com port) For Rs422, is the Rs-232 to Rs422 converter ON? Are you using an Auper cable? If no, is it Null modem? Check switch osition on back panel for the Com port selection (Rs232 or Rs422) TTL outputs The output connector of your Harpagon system can be used to drive other electronic devices. Each of the normally high (5 volts) 16 outputs will generate a pulse going to ground for each unit measured. If the Harpagon is calibrated to measure 250 ml, a pulse is generated each time the unit number changes. The outputs can be used to drive a portion control device used to fill containers for example. Pin out of the output connector Pins 1 to 16 = Outputs 1 to 16 Pin 24 = Harpagon Vcc 5 volts Pin 25 = Harpagon ground 19

21 Trouble shooting foamy draft beer 20 Draught beer is a sensitive product that requires a certain number of parameters to be just right Temperature, pressure, propellant and good beer system design. The Auper flow meter (turbine) is guaranteed not to make beer foam. However, the installation of flow meters into your beer lines will not solve the foaming problems. It would only tell you how much is wasted. Does the serving temperature correspond to the brewer s norms? North America: 38F (3.3C) & 42 F (5.5C) Pour a glass and insert a thermometer immediately in the freshly poured beer. If the temperature in the glass is outside these norms, it is quite possible that your refrigeration system is defective or needs adjustment. Too high a temperature will increase the risk of excessive foaming. If the beer is too cold, the beer is not foamy enough and bartenders usually serve more in each glass. In either case, you should be concerned that the pour cost will probably be too high. Is the flow rate between 2.5 and 3.5 l/min (Approx 2 oz/sec)? If the flow rate is too slow, it is probably due to a lack of pressure in the system. The C02 gas can separate from the beer while in the line causing the beer to foam at the tap. The color of the beer will change a few seconds after the tap is opened, passing from a clear and golden color to white. Is the beer flat or over carbonated? Any beer system with a distance between the kegs and the faucet greater than 10 feet (3 meters) should be pressurized using a mixture of air or nitrogen (70 %) and CO2 (30 %). Straight CO2 can be used for direct draw systems and very short runs (less than 10 feet or 3 M). Clean straight air can be used if the sales volume per day is very high. Otherwise, it either contaminates the beer (think of where the air is pumped from) or it will make the beer flat. The wrong choice of propellant will make the beer foam, make it flat or change the taste. In either case you will be wasting product thus increasing your pour cost. Get a qualified technician to look at the problem! Non-refrigerated kegs (Europe) Temperature is one of the elements that will affect draft beer along with pressure, the type of gas, the line design and the product itself. When kegs are stored in a non-refrigerated room (pasteurized beer only), an increase in the store room temperature will have an effect on the way the product pours at the faucet. The higher the storage temperature is, the more gas pressure will be required to dispense the beer properly. 20

22 Draft beer control 21 The draft beer system Your draft beer dispenser is designed to pour approximately 2 oz/second (60ml/sec). It takes approximately 5 seconds to pour 10 oz (300ml) in a 12 oz glass. A gas regulator installed near your beer kegs controls the flow of beer. The pressure is set by the installer and remains fixed. A draft beer keg weights about 140 lbs (63 kg) when full and as beer is dispensed the keg gets lighter until completely empty. That means that the flow of beer will increase as you empty your kegs (simple physics). It is specifically because of this normal flow increase that flow meters have to be used to measure the amount of draft beer dispensed accurately. Any device used for draft beer control, that is not capable of measuring and reporting the amount of beer dispensed, is probably inaccurate to the point of being almost useless. When you think about draft beer control, you should be concerned with two things: Sales and cost control Both are as important as the other in term of profit loss. This is clearly demonstrated when using the pour cost percentage calculator. Controlling sales In order for a beer monitoring system, a beer dispenser or a cash register to report if the beer was sold as a glass or a pitcher, there must be an action taken by the bartender to tell the machine. The type of action is one of two things: Pressing a button. Dispensing the amount. When the faucet is closed, the computer looks at the quantity poured and the corresponding counter is activated. The quantity poured can be evaluated by either a timer or by a flow meter. 21

23 Let s not forget who is pressing the buttons! 22 If a glass of beer sells for $ 2.00, and a pitcher sells for $ 8.00 (there is about 5 glasses in a pitcher), it is easy for anyone to press the pitcher button, and sell the beer in 5 glasses. There is an additional $ 2.00 going in the tip jar. Even if you had a portion control device, the bartender can easily press the pitcher button and pour the beer in 5 glasses. The machines report how many times each button was pressed. If you give a discount to your customers, be aware the some dishonest employees could be using it to their advantage. The presence of a trusted manager and a good price structure, reducing as much as possible these incentives, can do a lot more than electronics can. By measuring the draft beer dispensed you will force your bartenders to match the ounces (liters) served with the number of glasses sold making very hard for them to cheat the system. Can you imagine a bartender remitting a usage report that exceeds the sales report by 200 oz without looking a little guilty? Only the honest bartenders will be able to keep on working in your bar. The other ones will have to leave. You get the piece of mind and the profits they were costing you. Inventory control When you want to know how many bottles of beer were sold on a shift, you look at your cash register report and count the bottles left in the cooler to make sure they were all sold. Cash register errors are also detected using the inventory. In other words, you control sales and cost by checking your inventory. For draft beer (using our flow meter system) it is the same with a few variations. Inventory is calculated using flow meters. You count ounces or liters instead of bottles. With bottles you don t worry about the amount served to the customers. With draft beer you have to worry about over pouring and spillage since they can increase your pour cost dramatically. In order to control your draft beer sales and inventory accurately, you must first measure the amount of beer served in each glass, mug or pitcher sold in your bar. You can do that using the flow meter system by resetting the meters, pouring 10 glasses and averaging the amount dispensed per glass. The more glasses used for this sampling the more accurate your estimate will be. With this method, you can count how many glasses each keg should yield. If you already own a metering or dispensing system, you can verify its accuracy by comparing the number of glasses registered with the estimated yield per keg. 22

24 Reconciling sales using flow meters 23 The meters can be read three ways: Manually by the manager or by the bartender who goes to the system to write down the counts at the beginning and at the end of each shift. There is always the option of resetting the counters at the start of a shift. A usage report can be printed on a serial printer. The meter readings are saved and printed manually or automatically up to three times a day. The metering system is interfaced to a computer. The meter readings are initiated by the computer and stored on disk. Reports can be printed at any time for any period. Tips To reconcile your sales with your meters, you multiply the amount of each of the different sizes sold by the amount of beer each size contains (which you have previously measured). For bars with a larger number of brands, the reconciliation can be done more rapidly using a spreadsheet or using the Draft Manager 2004 software with the POS interface. Because you get a report telling you how much beer was served out of any given bar at any time, any problem you may have will show up at the end of the shift. You can deal with it immediately, reducing your pour cost and maximizing your profits at the same time. You may want to check is your glass sizes. Check all your glasses and be aware that some glasses look the same but don t contain the same amount of ounces (pay special attention to pitchers). Are you wasting a lot of beer to foam? If so, with the flow meters you will know how much it is costing you. If you want the problem fixed contact someone with the expertise to fix it. People with foam problems often think that it is normal. A good beer system will work well all the time. A bad beer system will cost you a lot of money. If you blow your beer lines at the end of a keg and lose a couple of pitchers in the process of tapping a new keg, you can solve the problem with empty beer keg detectors. These devices will shut off the beer flow and prevent gas from entering the empty line causing all the foaming when tapping a fresh keg. If you want to know how much beer goes down the drain, make sure the drainer empties into a graduated container instead of the sewer. You can deduct the amount wasted from the flow meter report for an absolute value of beer dispensed that should have been sold. 23

25 WARRANTY 24 Auper Electronic Controls Inc warrants that this product is in good working condition, according to its specifications at the time of the shipment, for a period of one (1) year from the date of purchase. Should the product, in Auper Electronic Controls opinion, malfunction within the warranty period, Auper Electronic Controls Inc will repair or replace the product without charge. Any replaced part becomes the property of Auper Electronic Controls Inc. This warranty does not apply to the software component of a product or a product which has been damaged due to an accident, misuse, abuse, improper installation, usage not in accordance with product specifications and instructions, natural or personal disaster or unauthorized alterations, repairs or modifications. LIMITATIONS All warranty for this product, expressed or implied, are limited to one year from the date of purchase and no warranty, expressed or implied, will apply after that period. No warranties for this product expressed or implied will apply to any person who purchases the product in used condition. The liability of Auper Electronic Controls Inc with respect to any defective product will be limited to the repair or replacement of such product. In no event shall Auper Electronic Controls Inc be responsible or liable for any damages arising (a) from the use of the product; (b) from the loss of use, revenue or profit of the product; or (c) as a result of any event, circumstances, action or abuse beyond the control of Auper Electronic Controls Inc ; whether such damage be direct, indirect, consequential, special or otherwise and whether such damages are incurred by the person to whom this warranty extends or a third party. 24

Harpagon flow meter system. User guide

Harpagon flow meter system. User guide Harpagon flow meter system User guide Harpagon Installation Guide I50654E Page 1 HARPAGON...2 General information...2 Power Source...3 Customer Support...3 Pre-installation considerations...3 1. Using

More information

TM600 Real time flow totalizer and transmitter

TM600 Real time flow totalizer and transmitter TM600 Real time flow totalizer and transmitter Installation and user guide Rev 1 Auper Electronic Controls Inc All rights reserved 2013 GENERAL INFORMATION FCC INFORMATION This device complies with Part

More information

Harpagon wiring instructions

Harpagon wiring instructions Harpagon wiring instructions A Cat 5 network cable is used to connect the flow meter collector box to the Harpagon metering system. A 25 ft cable is provided by default. You can order a longer cable when

More information

Auper Electronic Controls Inc. Eclipse 784 B. Quick User Guide

Auper Electronic Controls Inc. Eclipse 784 B. Quick User Guide Auper Electronic Controls Inc Eclipse 784 B Quick User Guide 2 2010 Auper Electronic Controls Inc Edition E784BE 1.2 INSTALLATION 1. Mount your Eclipse system, away from areas where liquor spills could

More information

Beverage Control Systems

Beverage Control Systems Beverage Control Systems Price list 2013 Effective December 1, 2012 NOTES: 1 Beverage control systems catalog www.auper.com BEVERAGE FLOW METERING SYSTEMS FLOW METER ONLY WITH LEXAN NUTS AND 25 FT (7.65

More information

Auper Electronic Controls Inc. Eclipse 4250 IE. Quick User Guide

Auper Electronic Controls Inc. Eclipse 4250 IE. Quick User Guide Auper Electronic Controls Inc Eclipse 4250 IE Quick User Guide 2 2015 Auper Electronic Controls Inc Edition EI4250BE 1.0 INSTALLATION 1. Connect the network cable to the Eclipse. This cable will be used

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1225 ParaLink TM Parallel Short Range Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1225-B Doc. #104011UB Revised 9/12/97 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

Nationwide Payment System 1500 W. Cypress Creek Road, Suite 503 FT. Lauderdale, FL Wireless Liquor Management System.

Nationwide Payment System 1500 W. Cypress Creek Road, Suite 503 FT. Lauderdale, FL Wireless Liquor Management System. Nationwide Payment System 1500 W. Cypress Creek Road, Suite 503 FT. Lauderdale, FL 33309 844.677.2265 Wireless Liquor Management System User Guide 3 INDEX Page 4 Using SKYFLO Pour Spout 6 Using the Washing

More information

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT Contains Operating and Programming Information Model ATV 4/6 Battery Powered Digital Vacuum Instrument ã 1996, Teledyne Electronic Technologies,

More information

Sonic Ruptor 400. User Manual

Sonic Ruptor 400. User Manual Sonic Ruptor 400 User Manual Data herein has been verified and validated. It is believed adequate for the intended use of the instrument. If the instrument or procedures are used for purposes over and

More information

AirPro Surveyor 2 Manual

AirPro Surveyor 2 Manual AirPro Surveyor 2 Manual AirPro Surveyor Specifications Table of Contents Size 3/8 x 7 1/2 x 4 3/8 Weight 4.6 lbs. 2094 g Dynamic Range 1-1000 ml/min. total flow/constant flow Flow Capacity (8 Hrs.) 1000

More information

TD2100 Electric Gummed Tape Dispenser Owner s Manual

TD2100 Electric Gummed Tape Dispenser Owner s Manual TD2100 Electric Gummed Tape Dispenser Owner s Manual Marsh Shipping Supply Co. LLC 926 McDonough Lake Road Collinsville, IL 62234 www.msscllc.com Customer Service Phone: (618)-343-1006 Fax: (618)-343-1016

More information

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

PMDX-170 Slotted Optical Sensor

PMDX-170 Slotted Optical Sensor PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc

More information

User s Guide. Pressure Controller for liquid delivery systems

User s Guide. Pressure Controller for liquid delivery systems Flow Control User s Guide Pressure Controller for liquid delivery systems Precise Pressure Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery

More information

Progressive Industries, Inc. EMS Electrical Management System

Progressive Industries, Inc. EMS Electrical Management System Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.

More information

An ISO-9001 Certified Company

An ISO-9001 Certified Company USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

Zonit μats TM Users Guide μats1-lv Version 1.2

Zonit μats TM Users Guide μats1-lv Version 1.2 Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational

More information

S-500 Snow Machine User Manual English

S-500 Snow Machine User Manual English S-500 Snow Machine User Manual English 2016 Antari Lighting and Effects Ltd. 2 User Manual Safety Information Please read the following safety information carefully before operating the machine. Information

More information

Multi-Mount for Mac Pro " to 5.25" Drive Bay Converter Bracket. Assembly & Installation Manual

Multi-Mount for Mac Pro  to 5.25 Drive Bay Converter Bracket. Assembly & Installation Manual Multi-Mount for Mac Pro 2009-2010 3.5" to 5.25" Drive Bay Converter Bracket Assembly & Installation Manual Introduction 1 INTRODUCTION 1.1 System Requirements 1.1.1 Computer Requirements 1.1.2 Hard Drive

More information

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

Cab Box Kit Dome Plug Cab Box Cab Box Lid

Cab Box Kit Dome Plug Cab Box Cab Box Lid DirectCommand Installation Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Direct Command Kit 4100578 1 Cable Installation

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual PMDX-108-Output 8-Channel Isolated Output Board for PC parallel port pins 2-9 User s Manual Date: 25 February 2010 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton,

More information

PRO 360. Owner's Manual

PRO 360. Owner's Manual One-Year Limited Warranty If, within one year from the date of original purchase, the Pro 360 Digital Protractor fails to function because of defects in materials or workmanship, the manufacturer will,

More information

PRO Owner's Manual

PRO Owner's Manual PRO 3600 Owner's Manual Feature Overview The Pro 3600 operates normally in a standard reference mode where level is displayed as 0.00. However, a new reference point for 0.00 can easily be established

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

MTX-A Temperature Gauge User Manual

MTX-A Temperature Gauge User Manual MTX-A Temperature Gauge User Manual 1. Installation... 2 1.1 Gauge Mounting... 2 1.2 Temperature Sensor Mounting... 2 1.2.1 Changing the MTX-A s Gauge Bezel... 2 1.3 Main Gauge Wiring... 3 1.3.1 Single

More information

Hi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL. For the 4600 Scale System For the 5600 Scale System

Hi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL. For the 4600 Scale System For the 5600 Scale System Hi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL For the 4600 Scale System For the 5600 Scale System September 1999 THE ACCURATE ON-BOARD ELECTRONIC SCALE For Air-Ride

More information

CHAPTER 3B: ELECTRONIC POWER STEERING

CHAPTER 3B: ELECTRONIC POWER STEERING Electronic Power Steering CHAPTER 3B: ELECTRONIC POWER STEERING NOTE: The basic steering system, such as the tie rod ends, drag links axles, etc., is covered in Chapter 3A: Steering. In 2012, Cub Cadet

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1 Installation and Operation Guide 70-210043-17 V 1.1 Copyright 2008 Remote Technologies Incorporated All rights reserved. 2 DECLARATIONS 117 612 914 DECLARATION OF CONFORMITY (DOC) The Declaration of Conformity

More information

DirectCommand Installation RoGator Model Year Ag Leader Technology

DirectCommand Installation RoGator Model Year Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Direct Command Kit 4100801 1 Dual Lock 2000052-9 1 Dual Lock 2000053-9 1 Quick Reference

More information

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental

More information

DVI Extender over Single CAT5 Model #: DVI-C5-M-SET

DVI Extender over Single CAT5 Model #: DVI-C5-M-SET DVI Extender over Single CAT5 Model #: DVI-C5-M-SET 2013 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview ) products. Avenview makes

More information

MANUAL. Set-up and Operations Guide Glidecam Industries, Inc. 23 Joseph Street, Kingston, MA Customer Service Line

MANUAL. Set-up and Operations Guide Glidecam Industries, Inc. 23 Joseph Street, Kingston, MA Customer Service Line MANUAL Set-up and Operations Guide Glidecam Industries, Inc. 23 Joseph Street, Kingston, MA 02364 Customer Service Line 1-781-585-7900 Manufactured in the U.S.A. COPYRIGHT 2015 GLIDECAM INDUSTRIES,Inc.

More information

User Manual rev: Made in Taiwan

User Manual rev: Made in Taiwan SP-1014 1x4 DVI Splitter over Single Cat.X with HDCP Support User Manual rev: 111209 Made in Taiwan The SP-1014 1x4 DVI Splitter over Single Cat.X with HDCP Support has been tested for conformance to safety

More information

Multi-Mount for Mac Pro to 5.25 Drive Bay Converter Bracket. Assembly & Installation Manual

Multi-Mount for Mac Pro to 5.25 Drive Bay Converter Bracket. Assembly & Installation Manual Multi-Mount for Mac Pro 2009-2010 3.5 to 5.25 Drive Bay Converter Bracket Assembly & Installation Manual 1 INTRODUCTION 1.1 System Requirements 1.1.1 Computer Requirements 1.1.2 Hard Drive Requirements

More information

PCM-7140 Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031

More information

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , & DirectCommand Installation Ag Leader Technology Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N 2005944, 2005945 & 2006383. Part Name/Description

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 2150 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many

More information

ECLIPSE. Online and Downloadable Product Manuals and Quick Start Guides are available at

ECLIPSE. Online and Downloadable Product Manuals and Quick Start Guides are available at ECLIPSE LAUNDRY DISPENSER CONTROLLER Reference Manual Programming and Operation Online and Downloadable Product Manuals and Quick Start Guides are available at www.novacontrols.com/instructions.htm. Don't

More information

Sapling Converter Box

Sapling Converter Box Installation Manual Sapling Converter Box SCB-100-000-1 Version Number 1.2 Current as of March 15, 2015 The Sapling Company, Inc. (+1) 215.322.6063 P. (+1) 215.322.8498 F. 2-Wire Converter Box (SCB-100-000-1)

More information

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA MC-1 MINI CAMERA OPERATION MANUAL JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA 02718 USA (508) 822-7330; (800) 822-4744; FAX (508) 880-8949 Email: info@jwfishers.com WEB: www.jwfishers.com SPECIFICATIONS

More information

MTP INSTRUCTION MANUAL

MTP INSTRUCTION MANUAL MTP INSTRUCTION MANUAL Wireless Electricity Monitor Model MTP-3100 MTP Instruments Inc. Table of Content 1. Introduction Page 1 2. Safety and Maintenance Information Page 1 3. Features / Specifications

More information

Plus-X AC-8. User Guide

Plus-X AC-8. User Guide Plus-X AC-8 User Guide Table of Contents Introduction... 1 Network Requirements... 1 Setup and Configuration... 1 Operation... 5 Uploading Firmware... 7 Getting Help... 7 Warranty... 7 Appendix A: Specifications...

More information

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X) SSP-550-X-(SSP-510-X)-LPSPKRPCB-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-550-X (FORMERLY SSP-510-X) HANDS FREE ELEVATOR PHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry Since

More information

Rackmount Keyboard Installation Instructions. Revision A A-0000

Rackmount Keyboard Installation Instructions. Revision A A-0000 Rackmount Keyboard Installation Instructions Revision A 22000200A-0000 WARRANTY The following is an abbreviated version of warranty policy for keyboard products. For a complete warranty statement, contact

More information

FT-20 Fire Training Fog Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English FT-20 Fire Training Fog Machine User Manual English 2018 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1000 Part No. 23624 OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1000 OV1000 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

EMS-LCHW30 & EMS-LCHW50

EMS-LCHW30 & EMS-LCHW50 Electrical Management System (EMS) EMS-LCHW30 & EMS-LCHW50 Installation & Operating Guide for: Model EMS-LCHW30 Rated at 120V/30A and Model EMS-LCHW50 Rated at 240V/50A Surgio Says Lifetime Warranty on

More information

C5C Cross-Connect System

C5C Cross-Connect System C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection

More information

SERVICE MANUAL MODEL SSW-520-F

SERVICE MANUAL MODEL SSW-520-F SSW-520-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-520-F HANDS FREE STAINLESS STEEL TELEPHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 West

More information

Installation & Operation Instructions

Installation & Operation Instructions Installation & Operation Instructions Deluxe Spot & Flood Light 405620-3 To avoid the risk of accidents or damage to this product, it is essential to read these instructions thoroughly before this product

More information

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

ICE FOG Q TM Low Fog Generator

ICE FOG Q TM Low Fog Generator Low Fog Generator USER GUIDE Revision A/d, May 2017, MDG Fog Generators Ltd MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard MDG Ltée / MDG Fog Generators Ltd 10301 avenue Pelletier, Montréal,

More information

SMD Series Integrated Stepper Driver and Motor Revision 1.3

SMD Series Integrated Stepper Driver and Motor Revision 1.3 The AMCI Integrated Stepper Motor and Microstepping Drive Combination represents the future of Stepper Motor Control applications. The SMD is a self-contained stepper motor and driver package, capable

More information

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem USER MANUAL MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem An ISO-9001 Certified Company Part #07M1003-B Doc. #050021UB Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL

More information

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F) SSC-301-F OR BLC-301-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-301-F (FORMERLY 301-FS) OR MODEL BLC-301-F (FORMERLY 301-F) CHARGE-A-CALL TELEPHONE Serving the Telephone Industry Since 1930 Communication

More information

EMS Electrical Management System

EMS Electrical Management System EMS Electrical Management System Complete Installation/Operating & Warranty Guide EMS-HW50C Rated at 240 Volts/50 Amps Manufactured & Warranted by Progressive Industries Sold & Serviced by VIP Enterprises

More information

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control Remote Control for Inverter RC-300 Owner's Manual Please read this manual BEFORE operating your RC-300 Remote Control OWNER'S MANUAL Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity DirectCommand Kit 4100800 1 Cable Installation Kit 2000901-1 1 Dielectric Grease 2002872

More information

MPP200 User s Manual

MPP200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental

More information

INTELLIGENT DOCKING STATION USERS MANUAL

INTELLIGENT DOCKING STATION USERS MANUAL Kodiak Mobile by Jotto Desk 209 W. Easy St., Rogers, AR USA 72756 Customer Service: 877.455.6886 http://www.kodiakmobile.com PART NUMBER: 450-4011 - Last Update: 06.2009 INTELLIGENT DOCKING STATION USERS

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information

Part Name/Description Part Number Quantity

Part Name/Description Part Number Quantity Part Name/Description Part Number Quantity Direct Command Kit 4100883 1 Installation Instructions 2006336 1 Hardware Kit Large Module 2001354-1 2 Cable Installation Kit 2000901-1 1 Quick Reference Card

More information

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1001 Part No. 23620 OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1001 OV1001 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

Installation Instructions

Installation Instructions Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for

More information

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control Remote Control for Inverter RC-200 Owner's Manual Please read this manual before operating your RC-200 Remote Control Owner's Manual Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

Manual. LC-16 system. LC-16 Inkjet Printer 1

Manual. LC-16 system. LC-16 Inkjet Printer 1 Manual LC-16 system LC-16 Inkjet Printer 1 Index ENVIRONMENT. 3 OPERATOR S SAFETY 3 OPERATION SAFETY 3 PART 1 INSTALLATION AND PARAMETER SETTING 4 1) Preparing 4 2) Installation 4 3) Priming 4 4) Parameter

More information

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan SP-1014 1x4 DVI over Single CAT5 Distribution Amplifier User Manual Made in Taiwan Safety and Notice The SP-1014 1x4 DVI over Single CAT5 Distribution Amplifier has been tested for conformance to safety

More information

AquaController Apex Probe Module 2

AquaController Apex Probe Module 2 AquaController Apex Probe Module 2 Setup Guide Table of Contents PROBE MODULE 2 INTRODUCTION... 1 FEATURES... 1 PHYSICAL INSTALLATION... 1 Initial Connections... 1 Startup... 2 VERIFY THE INSTALLATION...

More information

Pulse LED Instruction Guide

Pulse LED Instruction Guide PARTS LIST Light Fixture Aquarium Frame Mounts Instruction Guide WARNING: To guard against injury, basic precautions should be observed, including the following: A) READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

More information

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19 Note: These installation instructions only cover installation on SPX 4420 Sprayers only. For installation on SPX 3230/3330 Sprayers refer to Installation Instructions P/N 2005945. For SPX 4430 refer to

More information

PMDX-105 Quad Isolator Board

PMDX-105 Quad Isolator Board PMDX105 Quad Isolator Board User s Manual Date: 18 April 2011 PMDX Web: http://www.pmdx.com 9704D Gunston Cove Rd Phone: 1 (703) 3722975 Lorton, VA 220792366 USA FAX: 1 (703) 3722977 PMDX105_Manual_10.doc

More information

Badger Meter Europa GmbH. INSTRUCTION MANUAL Deluxe LCD display for the MN series. September Version MN-Deluxe LCD display-09/01-e

Badger Meter Europa GmbH. INSTRUCTION MANUAL Deluxe LCD display for the MN series. September Version MN-Deluxe LCD display-09/01-e Badger Meter Europa GmbH INSTRUCTION MANUAL Deluxe LCD display for the MN series September 2001 Version MN-Deluxe LCD display-09/01-e Content Content Page 1. To the owner 1 2. Important information 1 3.

More information

MODEL 8000MP LEVEL SENSOR

MODEL 8000MP LEVEL SENSOR 1 MODEL 8000MP LEVEL SENSOR INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE VISIT OUR WEBSITE SIGMACONTROLS.COM 2 SERIES 8000MP LEVEL SENSOR 1. DESCRIPTION The Model 8000MP Submersible Level Sensor

More information

LBC-H/V-T-WP LINK BRIDGE TM HDMI/VGA WALL PLATE TRANSMITTER SYSTEM

LBC-H/V-T-WP LINK BRIDGE TM HDMI/VGA WALL PLATE TRANSMITTER SYSTEM LBC-H/V-T-WP LINK BRIDGE TM HDMI/VGA WALL PLATE TRANSMITTER SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed as a

More information

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21) Introduction The iport IW Balanced Audio, Balanced Video, and RS-232 Upgrade Kits add functionality and capability to iport IW-21 and IW-22 models. Balanced Audio Upgrade Kit For use with iport IW-21 models.

More information

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY CUSTOMER SERVICE If you have any questions or require additional information please contact Customer Service at 877-455-6886, Monday though Friday, 8:00am - 5:00pm CST. TECHNICAL SUPPORT Kodiak Mobile

More information

NT1B-300 Rack Installation Instructions

NT1B-300 Rack Installation Instructions The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies

More information

AE21 SERIES DISPLAY CONTROL TERMINAL

AE21 SERIES DISPLAY CONTROL TERMINAL FN:AE21MAN1.DOC AE21 SERIES DISPLAY CONTROL TERMINAL DESCRIPTION The AE21 Series Display Control Terminal is used for implementing various display functions. It consists of a control terminal, the AE21,

More information

INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH

INSTALLATION INSTRUCTIONS 5 SINGLE CHANNEL ULTIMATE TACH Instr. No. 2650-887C INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH MODEL 6871, 6872, 6873, 6874, 6875, 6877 IMPORTANT WEAR SAFETY GLASSES 5 4 6 COPYRIGHT PATENT PENDING 3 7 8 PLAYBACK 9 2 0

More information

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA PD10 Pulse Divider Instructions PROUDLY MADE IN THE USA ISO 001:200 Certified Company General Information General Information...Page 3 Features...Page 3 Specifications...Page 4 Installation Mounting...Page

More information

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description RAD-0501 Greenhouse Mode: Controls CO2 generator or regulator to increase CO2 levels during daylight

More information

GARNET. SEELEVEL II TM Tank Monitor INSTRUMENTS LTD. Model 709 Owner s Manual IMPORTANT OPERATOR INFORMATION DATE INSTALLED: SERIAL NUMBER:

GARNET. SEELEVEL II TM Tank Monitor INSTRUMENTS LTD. Model 709 Owner s Manual IMPORTANT OPERATOR INFORMATION DATE INSTALLED: SERIAL NUMBER: GARNET INSTRUMENTS LTD. SEELEVEL II TM Tank Monitor Model 709 Owner s Manual IMPORTANT OPERATOR INFORMATION DATE INSTALLED: SERIAL NUMBER: Signal Level Sender Height Black Water Tank Grey Water Tank Fresh

More information

VADDIO /CANON BU-SERIES PTZ CAMERAS

VADDIO /CANON BU-SERIES PTZ CAMERAS Camera and Electronic Products for Integrators Installation and User Guide VADDIO /CANON BU-SERIES PTZ CAMERAS Canon BU-45H Outdoor & BU-50H Indoor PTZ Cameras including Vaddio accessories for easy integration

More information

Installation Instructions

Installation Instructions Please read all instructions before installing SPECIFICATIONS RT-100 Time Switch Programmable Countdown Voltage...120VAC, 60HZ Load (Single Pole Circuit) Incandescent or fluorescent lamp... 0 600 Watt

More information

Owner s s Manual. G5 SATA Double Drive Internal Mounting Kit. Apple Macintosh G5. Add 2 SATA drives to the G5

Owner s s Manual. G5 SATA Double Drive Internal Mounting Kit. Apple Macintosh G5. Add 2 SATA drives to the G5 Owner s s Manual Add 2 SATA drives to the G5 G5 SATA Double Drive Internal Mounting Kit Apple Macintosh G5 SATA (Serial ATA) 2 Internal Drive System Table of Contents User Guide Page How SATA (Serial ATA)

More information

Part Name/Description Part Number Quantity

Part Name/Description Part Number Quantity Part Name/Description Part Number Quantity Direct Command 4200159 1 Cable Installation Kit 2000901-1 1 Hood 37-pin DSub 2001808-37 2 Dielectric Grease 2002872 1 Dust Plug 12 Pin Gray 2002899-12N 1 Feature

More information

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 10, or 15 -BK Braille Keypad -PBVC Pushbutton volume control

More information

MSD Enhancer Ignition for the Honda TRX400EX PN /PN 4203

MSD Enhancer Ignition for the Honda TRX400EX PN /PN 4203 MSD Enhancer Ignition for the Honda TRX400EX PN 05-00-4203/PN 4203 Parts Included: 1 - Programmable Enhancer Ignition 1 - Y-Splice 1 - MSD Coil Assembly 1 - Black Ground Wire 1 - Ignition Mounting Brackets

More information

DirectCommand Installation 5 Channel Spreader Control Module Technology

DirectCommand Installation 5 Channel Spreader Control Module Technology DirectCommand Installation Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Direct Command Kit 4100582 1 Cable Installation

More information