Paper Title Last Name First Name Session A Comparison of Two Inter-Laboratory Measurement Comparison Method

Size: px
Start display at page:

Download "Paper Title Last Name First Name Session A Comparison of Two Inter-Laboratory Measurement Comparison Method"

Transcription

1 Paper Title Last Name First Name Session Company A Comparison of Two Inter-Laboratory Measurement Comparison Method Nicholas Ricardo III-D The Boeing Company A High Precision And Fast Ultrasonic System For Huang C.F. VI-C Indoor Temperature Measurements A High Precision Ultrasonic System For The Huang C.F. VI-C Ultrasound's Velocity Measurements A Laser Non-Contact Measurement of Static Positioning and Dynamic Contouring Accuracy of a Wang Charles III-A Optodyne CNC Machine Tool A New Method For Automated Calibration Of Low Pressure Transfer Standards Haines Robert V-A DH Instruments A Standardized Laser Tracker Calibration System Sawyer Daniel II-A NIST Absolute Area Measurements of Circular Radiometric Apertures Litorja Maritoni I-D NIST An Approach for the Analysis of Interlaboratory Evaluations Based on the ISO Guide to the Kacker Raghu I-D 90 Expression of Uncertainty in Measurement An Introduction of Measurement technology in Physiology Research Application-The Design of a Vibration Sensor for Animal Behavior Li Yan-Chay II-C I-Shou Measurements Analysis Of Mass Measurement Data To Investigate Between-Time Component Of Error Schoonover Randall IV-A Application and Calibration of Virtual Test Instruments Tailored to Navy Metrology Requirements Walden Jeff III-B NSWC Corona

2 Applying Laser Metrology Systems for Machine Tool and CMM Error Mapping and Compensation Ma Quan II-A Automated Precision Balance Repeatability and Reproducibility Effects Westinghouse Savannah Schull Harper IV-A on Measurement Uncertainty River Company Basic Dynamical Modeling of Expanding Volume Flow Calibrators Maginnis Tom IV-B Kinetics Calibration Intervals - New Models and Techniques Jackson Dennis II-D NSWC Corona Components of a Quality Calibration for Pipettes & Bonnell Other Volumetric Instruments Kenneth V-C Henry Troemner, LLC Consumer Risk for Non-Gaussian Measurand Distributions Nicholas Ricardo III-D The Boeing Company Coordinate Measuring Machine Probes For Measuring Small Structures Stone Jack I-A NIST Deformation Corrections in Gage Block Calibration Doiron Ted I-A NIST Design The Strategy For Diameter Measurement of New South Pumhirun Nalin II-A Using Coordinate Measuring Machine Wales, School of Manufacturing and Mechanical Engineering Doppler Global Velocimetry (DGV): A Whole Field Technique for Flow Research and its Capabilities Dopheide Dietrich VI-B PTB for Flowrate Measurements Error Mapping and Calibration of Laser Tracker Systems Lau Kam II-A Automated Precision Errors on the Bench Top - Uncertainty and Bias of Rodriguez Pipettes in the Working Laboratory George IV-C Artel

3 Evaluation of a Non-Contact Thread Measurement Stanfield System Eric III-A NIST Flow Measurement Key Comparisons: Statistical Design and Analysis Bases for Multiple-Meter Mattingly George IV-B NIST Transfer Standards Further Analysis Of Ball Pressure Gage Calibration Data By The Development Of Linear And Quadratic Jones Frank V-A NIST (retired) Equations Gravimetric & Spectrophotometric Errors Impact Westinghouse Savannah Clark John P. V-C On Pipette Calibration Certainty River Company Guiding your Organization through Laboratory Accreditation, A Technical Manager s Experience Cenker Greg I-B Fluke Electronics History of the World Wide Web Gonzalez David II-B NSWC Corona Implementing XML Technology for Metrology? A Case Study Gonzalez David II-B NSWC Corona Improvements in NIST's Optical Technology Division Measurements and Services Bruce Sally III-C NIST Improving the Efficiency of Multifunction Calibrator Morton Calibration Systems John I-C Fluke Electronics Integrated Manual and Automated XML Calibration Cunavelis Procedure Development Michael II-B NSWC Corona Maintaining Traceability of Flow Measurement Standards Kegel Tom IV-B CEESI NCSLi Interlaboratory Comparison Measurement Protocol for UV Irradiance Larason Thomas III-C NIST NIST Standard Casings Project Song John VI-C NIST

4 Power Quality Measurement Coombes David I-C Recommended Guide for Determining and Reporting Uncertainties for Balances and Scales Rental Companies: How Can They Help You? Results Of The SIM 1-Litre Volume Comparison. Sector-Specific Accreditation Requirements Special Topics in Uncertainty Calculation Static Volume Calibration and Uncertainty by Gravimetric Method Miller Val IV-A NIST Fluke Precision Measurement Ltd. Jenson Cory VI-D Technology Rentals and Services Elsayed Mohamed V-D NIST Franklin Chet I-B DynCorp Stein Philip IV-D Stein Consultants Hazariam Emil IV-C LA County Weights and Measures Department Sub-Pixel Limitation of Imaging Sensor Mufti Asif III-A Systematic Uncertainties of Calculated Diffraction Corrections Educacion y Entrenamiento de Metrologia The Accuracy and Versatility of the NIST M48 Coordinate Measuring Machine The Effectiveness of Artifact Calibration in Computing Internal Resistance Values The EUROMET Future Flow Testing Plans The First UK National Standard Static Torque Calibration Machine New Design Concepts Lead The Way Shirley Eric I-D NIST Selzer Paul VI-D Braun Stoup Martson John I-A NIST David I-C Fluke Electronics Dopheide Dietrich V-B PTB Davis Francis V-A NPL

5 The New CIPM Working Group for Fluid Flow (WGFF): Plans and Progress Mattingly George V-B NIST The New NIST Policy on Traceability Ehrlich Charles VI-D NIST The Ongoing Investigation Into The Accuracy Of Multiple Critical Flow Venturis Mounted In A Caron Richard IV-B Visteon Corporation Common Plenum The Role of Marketing and Customer Service Powell Greg VI-D The Signal Group The Standard Uncertainty of Photometric Volume Measurements Examples from the Dual Dye Ratio- Rodriguez George V-C Artel Metric Method The Theory and Operation of Optical Chilled Mirror General Eastern Soleyn Kenneth VI-A Hygrometers for Humidity Calibration Instruments Time Distribution Using the World Wide Web Novick Andrew III-B NIST Transducer Compensation Adjustment After Installation Anderson Karl II-C Valid Measurements Two-Layer Sensor Matrix and Data Acquisition System Design in Spatial Temperature and Liu Tang-Jen VI-A Humidity Measurement Uncertainty Analysis of a High-Speed Dry Piston Flow Prover Padden Harvey VI-B BIOS International Virtual Instrumentation for Metrology Applications Smith Greg III-B National Instruments XML Technology Today, Standardization, and Storage Benefits Taylor John II-B Software AG

Papers by Session. II-A Ma Quan Automated Precision

Papers by Session. II-A Ma Quan Automated Precision I-A Doiron I-A Stone I-A Stoup I-B Franklin I-B Cenker I-C Martson I-C Morton I-C Coombes I-D Kacker I-D Litorja I-D Shirley II-A Lau Ted NIST Deformation Corrections in Gage Block Calibration Jack NIST

More information

Calibration of Optical Rotary Tables using Autocollimators and Laser Interferometer Systems

Calibration of Optical Rotary Tables using Autocollimators and Laser Interferometer Systems Calibration of Optical Rotary Tables using Autocollimators and Laser Interferometer Systems Prof. S. Zahwi, Prof. M. Amer, National Institute for Standard, Egypt; Prof. M. A. Abdo, Al-Azhar University,

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Productivity Quality, Inc./Advanced Inspection

More information

Understanding MFC Metrology & Calibration

Understanding MFC Metrology & Calibration Understanding MFC Metrology & Calibration Factors Impacting MFC Performance in Biopharmaceutical Process Systems 1 Understanding MFC Metrology & Calibration Mass flow controllers (MFCs) precisely deliver

More information

January/February 1995 March/April 1995 May/June 1995 July/August 1995 September/October 1995 November/December 1995 January/February 1996

January/February 1995 March/April 1995 May/June 1995 July/August 1995 September/October 1995 November/December 1995 January/February 1996 January/February 1995 Accurate Traceable Power Calibration at High Frequencies Guest Editorial: Certifying the Certifier Streamlining the Documentation Process for ISO 9000 March/April 1995 The Josephson

More information

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLO-CAL A portable Liquid Flow Standard FLO-CAL INSTRUMENT Data acquisition and interface tool with flow meter frequency and analog signals.

More information

The Virtual CMM a software tool for uncertainty evaluation practical application in an accredited calibration lab

The Virtual CMM a software tool for uncertainty evaluation practical application in an accredited calibration lab The Virtual CMM a software tool for uncertainty evaluation practical application in an accredited calibration lab Michael Trenk *, Matthias Franke **, Dr. Heinrich Schwenke ** * FEINMESS GmbH&Co. KG **

More information

Measurements in Fluid Mechanics

Measurements in Fluid Mechanics Measurements in Fluid Mechanics 13.1 Introduction The purpose of this chapter is to provide the reader with a basic introduction to the concepts and techniques applied by engineers who measure flow parameters

More information

2015 APMP TC Initiative Project

2015 APMP TC Initiative Project 015 APMP TC Initiative Project - Research on the Uncertainty Evaluation and Inter-comparison of 3D Pitot Tubes for Measuring Greenhouse Gas Emission Speaker: Chun-Min Su Participants: CMS: Hsin-Hung Lee,

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Productivity Quality, Inc./Advanced Inspection

More information

Axes 150 mm/s 150 mm/s. Y axis Z axis Vector 260 mm/s 260 mm/s. P in µm P in µm

Axes 150 mm/s 150 mm/s. Y axis Z axis Vector 260 mm/s 260 mm/s. P in µm P in µm ZEISS PRO / Specifications Version: May 2016 System description ZEISS PRO Models Operating mode Sensor mounts Software Horizontal-arm measuring machine on X-axis guide for flush-floor installation Horizontal-arm

More information

Calibration System for Thermo Hygrometers with Climatic Chamber

Calibration System for Thermo Hygrometers with Climatic Chamber Calibration System for Thermo Hygrometers with Climatic Chamber Climatic chamber-based calibration system for big probes and classic instruments by direct comparison Climatic chamber and reference thermo

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Exploration Drive Aberdeen Science and Energy Park Aberdeen AB23 8HZ Contact: Mr Graham Robertson Tel: +44(0)1224 708500 Fax: +44(0)1224 772

More information

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE I IMEKO World Congress Fundamental and Applied Metrology September 6, 9, Lisbon, Portugal COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER

More information

Ellab Temperature Indicator

Ellab Temperature Indicator Ellab Temperature Indicator FDA compliant alternative to mercury-inglass thermometers for retort monitoring - and much more ETI Ellab Temperature Indicator The ETI is availble in three different configurations

More information

Flow Measurement Applications

Flow Measurement Applications Flow Measurement Applications ONICON has been a leading provider of the flow and energy measurement solutions required by the HVAC industry for the past 30 years. As the need for accurate and reliable

More information

AN EVALUATION OF NON-CONTACT LASER SCANNER PERFORMANCE USING CALIBRATED ARTIFACTS

AN EVALUATION OF NON-CONTACT LASER SCANNER PERFORMANCE USING CALIBRATED ARTIFACTS AN EVALUATION OF NON-CONTACT LASER SCANNER PERFORMANCE USING CALIBRATED ARTIFACTS Michael Gomez, Colleen Vaccaro, Chase Maness, Connor Lawrence, Carson Murray, Luis Vargas, Greg Caskey, Chris Evans, and

More information

[ Capture Hoods. What is a capture hood?

[ Capture Hoods. What is a capture hood? [ Capture Hoods 2 What is a capture hood? A capture hood (flow measuring hood) is an instrument used to measure volumetric air flows from supply or exhaust diffusers and grilles. The Alnor version of the

More information

Purpose of Today s Presentation

Purpose of Today s Presentation Metering, Monitoring, and Verification APPA Institute for Facilities Management February 6, 2014 Purpose of Today s Presentation To provide a broad understanding of: Metering installation and application

More information

REFERENCE GENERATOR FOR CALIBRATION OF HUMIDITY AND TEMPERATURE INSTRUMENTS

REFERENCE GENERATOR FOR CALIBRATION OF HUMIDITY AND TEMPERATURE INSTRUMENTS HUMIDITY AND TEMPERATURE CALIBRATOR REFERENCE GENERATOR FOR CALIBRATION OF HUMIDITY AND TEMPERATURE INSTRUMENTS BASED ON AIRCHIP DIGITAL TECHNOLOGY TRANSPORTABLE HUMIDITY AND TEMPERATURE CALIBRATION LABORATORY

More information

STUDY OF FLOW PERFORMANCE OF A GLOBE VALVE AND DESIGN OPTIMISATION

STUDY OF FLOW PERFORMANCE OF A GLOBE VALVE AND DESIGN OPTIMISATION Journal of Engineering Science and Technology Vol. 12, No. 9 (2017) 2403-2409 School of Engineering, Taylor s University STUDY OF FLOW PERFORMANCE OF A GLOBE VALVE AND DESIGN OPTIMISATION SREEKALA S. K.

More information

good check of volumetric accuracy. However, if the mea error components. However, if the errors measured are large,

good check of volumetric accuracy. However, if the mea error components. However, if the errors measured are large, REVIEW OF SCIENTIFIC INSTRUMENTS VOLUME 71, NUMBER 10 OCTOBER 2000 Laser vector measurement technique for the determination and compensation of volumetric positioning errors. Part I: Basic theory Charles

More information

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6. CONTENTS TITLE PAGE 1. Introduction.. 1 2. Specifications... 1 3. Symbol Definition and Button Location... 2 4. Operation Instructions.... 3 4.1 Power-Up...3 4.2 Connection of the Temperature Probe...

More information

PRODUCT BROCHURE DEA MICRO-HITE. Handy and Cost-Effective CMM

PRODUCT BROCHURE DEA MICRO-HITE. Handy and Cost-Effective CMM PRODUCT BROCHURE DEA MICRO-HITE Handy and Cost-Effective CMM DEA MICRO-HITE Micro-Hite, the line of small CMMs featuring excellent performance, is the result of the synergy among Hexagon Metrology companies

More information

Coordinate Measuring Machines with Computed Tomography

Coordinate Measuring Machines with Computed Tomography Always a Step Ahead with Quality Coordinate Measuring Machines with Computed Tomography Multisensor Coordinate Measuring Machines with Computed Tomography Computed Tomography in Coordinate Measuring Machines

More information

SPECIFICATION SHEET Electronic Force Proving Instrument (For verification of uni-axial testing machine) MODEL : FS-117F

SPECIFICATION SHEET Electronic Force Proving Instrument (For verification of uni-axial testing machine) MODEL : FS-117F Applications For calibrating Uni-axial testing machines, universal testing machines, Compression and Tensile testing machine as per IS:1878, ISO 7500 or any other international standards Suitable for metrology

More information

SWING ARM OPTICAL CMM

SWING ARM OPTICAL CMM SWING ARM OPTICAL CMM Peng Su, Chang Jin Oh, Robert E. Parks, James H. Burge College of Optical Sciences University of Arizona, Tucson, AZ 85721 OVERVIEW The swing arm profilometer described in reference

More information

DTI-1000 and STS-100. Reference Digital Temperature Indicator

DTI-1000 and STS-100. Reference Digital Temperature Indicator t e m p e r a t u r e Reference Digital Temperature Indicator DTI-1000 and STS-100 Wide temperature range DTI-1000: -200 to 750 C (-328 to 1382 F) STS-100: -150 to 650 C (-238 to 1202 F) Improve your accuracy

More information

ARL OESIADAU INNOVATIONS

ARL OESIADAU INNOVATIONS ARL OESIADAU INNOVATIONS About Us Contacts Opto-Mechanical Design Precision OPtical Polishing Surface metrology Case Studies About Us Ltd is a technology company, located in the OpTIC Centre, a large scale

More information

TECHNICAL PRESENTATION FLOW METER CALIBRATION SYSTEM. G Rajabaskaran Vice Chairman

TECHNICAL PRESENTATION FLOW METER CALIBRATION SYSTEM. G Rajabaskaran Vice Chairman TECHNICAL PRESENTATION FLOW METER CALIBRATION SYSTEM 1 G Rajabaskaran Vice Chairman Nagman is an ISO 90001:2008 certified company and serving the global market since 1972 Our calibration lab is accredited

More information

Complete 3D measurement solution

Complete 3D measurement solution Complete 3D measurement solution Complete access The S neox Five Axis 3D optical profiler combines a high-accuracy rotational module with the advanced inspection and analysis capabilities of the S neox

More information

Laser Doppler Displacement Meter Laser Measurement System

Laser Doppler Displacement Meter Laser Measurement System Laser Doppler Displacement Meter Laser Measurement System Title: Incoming inspection procedure Document identification: MCV 500 incoming OPTODYNE, INC. 1180 Mahalo Place Compton, CA 90220 310-635-7481

More information

High Performance, Full-Digital Control on the LMT and KVN Telescopes

High Performance, Full-Digital Control on the LMT and KVN Telescopes High Performance, Full-Digital Control on the LMT and KVN Telescopes David R. Smith (MERLAB), alpha@merlab.com Kamal Souccar (UMass), David Gale (INAOE), F. Peter Schloerb (Umass), David Hughes (INAOE)

More information

Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION

Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION Precimar Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION Mahr's universal length measuring machines are designed for absolute and relative measurement

More information

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool 1523/1524 Reference Thermometers Measure, graph and record three sensor types with one tool Finally, a reference thermometer as versatile as you The 1523/24 Reference Thermometers from Fluke Calibration

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 J.H. METROLOGY CO., INC. 1801 Hicks Road, Unit E Rolling Meadows, IL 60008 Neil E. Willert Phone: 847 991 0290 CALIBRATION Valid To:

More information

Mass Flow Meters, Controllers and Manifolds

Mass Flow Meters, Controllers and Manifolds to get there. together. Mass Flow Meters, Controllers and Manifolds Swiss made High-performance gas flow control for OEMs Overview Axetris offers OEM Mass Flow Meters (MFM), Controllers (MFC) and Manifolds

More information

Fluke 744 Documenting Process Calibrator-HART

Fluke 744 Documenting Process Calibrator-HART Fluke 744 Documenting Process Calibrator-HART The 744 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for

More information

Investigating the volumetric performance of multi-axis measurement arms

Investigating the volumetric performance of multi-axis measurement arms Investigating the volumetric performance of multi-axis measurement arms J.Singh, M.Hughes & J N Petzing Wolfson School of Mechanical & Manufacturing Engineering Loughborough Universty, UK Abstract Multi-axis

More information

MONITORING THE REPEATABILITY AND REPRODUCIBILTY OF A NATURAL GAS CALIBRATION FACILITY

MONITORING THE REPEATABILITY AND REPRODUCIBILTY OF A NATURAL GAS CALIBRATION FACILITY MONITORING THE REPEATABILITY AND REPRODUCIBILTY OF A NATURAL GAS CALIBRATION FACILITY T.M. Kegel and W.R. Johansen Colorado Engineering Experiment Station, Inc. (CEESI) 54043 WCR 37, Nunn, CO, 80648 USA

More information

Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter

Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter Volume measuring unit [ Highest measurement accuracy ULTRAHEAT XS measures flow rate by the ultrasonic dragging principle. Two transducers alternately

More information

Ch 22 Inspection Technologies

Ch 22 Inspection Technologies Ch 22 Inspection Technologies Sections: 1. Inspection Metrology 2. Contact vs. Noncontact Inspection Techniques 3. Conventional Measuring and Gaging Techniques 4. Coordinate Measuring Machines 5. Surface

More information

Laboratory Accreditation Programmes

Laboratory Accreditation Programmes Laboratory Address PO Box 79085, Avonhead, Christchurch, 8446 3 Homersham Place, Burnside, Christchurch, 8053 Telephone 03 358-8309 Fax 03 358-2516 URL Authorised Representative Client No. 85 Programme

More information

Page : 1 of 40. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY (CMC*)

Page : 1 of 40. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY (CMC*) Caltek Pte Ltd Certificate No. : LA-2003-0292-C 23 Tagore Lane #04-08/09/10/11 Issue No. : 15 Tagore 23 Warehouse Singapore 787601 Date : 15 November 2017 FIELD OF TESTING : Calibration and Measurement

More information

HIGH SPEED PROJECTILE RECORDING SYSTEM

HIGH SPEED PROJECTILE RECORDING SYSTEM International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 1 HIGH SPEED PROJECTILE RECORDING SYSTEM Dileep Kumar 1, Anshul Gaur 2, 1,2 EI Dept., RGGI Meerut dileep.inst@gmail.com,

More information

A FEW CASE STUDIES IN UNCERTAINTY USING THE NIST M48 CMM

A FEW CASE STUDIES IN UNCERTAINTY USING THE NIST M48 CMM A FEW CASE STUIES IN UNCERTAINTY USING THE NIST M48 CMM John Stoup Precision Engineering ivision National Institute of Standards and Technology Gaithersburg, Maryland 20899 INTROUCTION The Moore M48 coordinate

More information

Guideways X axis Precision-manufactured, anodized extruded profile made of light metal. On stabilized, welded steel supports

Guideways X axis Precision-manufactured, anodized extruded profile made of light metal. On stabilized, welded steel supports ZEISS MMZ E Specifications Version: November 2017 System description Type according to ISO 10360-1:2000 Gantry CMM Guideways X axis Precision-manufactured, anodized extruded profile made of light metal

More information

Purpose of Today s Presentation

Purpose of Today s Presentation Metering, Monitoring, and Verification Part 1 APPA Institute for Facilities Management Scottsdale, AZ September 15, 2015 Purpose of Today s Presentation To provide a broad understanding of: Metering installation

More information

Precimar. PLM and CiM Universal Length Measuring Machines

Precimar. PLM and CiM Universal Length Measuring Machines 24 Precimar. Precision Length Metrology Precimar. PLM and CiM Universal Length Measuring Machines LENGTH MEASURING MACHINES FOR HIGH-END CALIBRATION Mahr's universal length measuring machines are designed

More information

Custody Transfer Accuracy in an 8-Path Ultrasonic Flow Meter with 5D Upstream Straight Run

Custody Transfer Accuracy in an 8-Path Ultrasonic Flow Meter with 5D Upstream Straight Run Custody Transfer Accuracy in an 8-Path Ultrasonic Flow Meter with 5D Upstream Straight Run Author: Nick Mollo, Principal Engineer Presenter: Gerard Bottino, Global Sales Manager Flow gerard.bottino@bhge.com

More information

Temperature Measurement and Calibration. Industrial Calibration Selection Guide. Multifunction Process Calibrator.

Temperature Measurement and Calibration. Industrial Calibration Selection Guide. Multifunction Process Calibrator. Multifunction Process Calibrator Industrial Calibration Selection Guide Look inside for: Field Metrology Wells Infrared Calibrators Handheld and Field Dry-Wells 1 Temperature Measurement and Calibration

More information

EXPLORER CLASSIC BRIDGE COORDINATE MEASURING MACHINE PRODUCT BROCHURE

EXPLORER CLASSIC BRIDGE COORDINATE MEASURING MACHINE PRODUCT BROCHURE EXPLORER CLASSIC BRIDGE COORDINATE MEASURING MACHINE PRODUCT BROCHURE EXPLORER CLASSIC UNSURPASSED MEASURING RANGE Available in sizes to suit every kind of business, Explorer Classic machines combine innovative

More information

Reliable Force Measurement

Reliable Force Measurement Reliable Force Measurement HBM force transducers for industry and research HBM force transducers HBM force transducers Versatile in Use, Proven Worldwide HBM always offers the right solution Full range

More information

Supplied with. Calibration certificate. HD 200 Hygrometer

Supplied with. Calibration certificate. HD 200 Hygrometer Supplied with Calibration certificate HD 200 Hygrometer Table of contents 3 I Technical specifications...4 Technical features......4 Specifications......4 II Introduction......5 Description......5 Connections......6

More information

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions DBC SERIES DBC 150/650 Series Dry Block Temperature Calibrators 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com! s from -45º to 650ºC! Rapid heating, cooling and settling!

More information

Using Capacitance Probes to Measure the Limit of Machine Contouring Performance

Using Capacitance Probes to Measure the Limit of Machine Contouring Performance Using Capacitance Probes to Measure the Limit of Machine Contouring Performance Don Martin, Lion Precision, 563 Shoreview Park Road, St. Paul, NIN 55126 Most machine tools used for discrete part manufacturing

More information

Resource Inspections Canada Inc. Certification Scheme Requirements

Resource Inspections Canada Inc. Certification Scheme Requirements 1. Purpose To describe the requirements for certification scheme for certified calibration laboratory technician for mechanical calibrations conducted by Resource Inspections Canada Incorporated. This

More information

Pixel Size Calibration of Video Probe Measuring Machines James G. Salsbury Center for Precision Metrology University of North Carolina at Charlotte

Pixel Size Calibration of Video Probe Measuring Machines James G. Salsbury Center for Precision Metrology University of North Carolina at Charlotte Pixel Size Calibration of Video Probe Measuring Machines James G. Salsbury Center for Precision Metrology University of North Carolina at Charlotte Coordinate measuring machines (CMMs) equipped with video

More information

Motion Analysis Methods. Gerald Smith

Motion Analysis Methods. Gerald Smith Motion Analysis Methods Gerald Smith Measurement Activity: How accurately can the diameter of a golf ball and a koosh ball be measured? Diameter? 1 What is the diameter of a golf ball? What errors are

More information

CyberGage360 3D SCANNERS. One-Button Automation for 3D Scan Inspection.

CyberGage360 3D SCANNERS. One-Button Automation for 3D Scan Inspection. CyberGage360 One-Button Automation for 3D Scan Inspection. 3D SCANNERS Unprecedented speed, accuracy and one-button simplicity for non-contact automated 3D scanning inspection. Powered by MRS Technology

More information

Conductivity Transmitters

Conductivity Transmitters Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows

More information

Model S471 Portable Optometer

Model S471 Portable Optometer Model S471 Portable Optometer With over 50 years of experience in developing light measurement instruments, Gamma Scientific is trusted by the world s leading organizations to provide accurate results.

More information

An introduction to the National Voluntary Laboratory Accreditation Program

An introduction to the National Voluntary Laboratory Accreditation Program An introduction to the National Voluntary Laboratory Accreditation Program Sally Bruce, Chief for the National Voluntary Laboratory Accreditation Program (NVLAP) NIST Headquarters Gaithersburg, MD The

More information

MSA-500 Micro System Analyzer. Measuring 3-D Dynamics and Topography of MEMS and Microstructures

MSA-500 Micro System Analyzer. Measuring 3-D Dynamics and Topography of MEMS and Microstructures MSA-500 Micro System Analyzer Measuring 3-D Dynamics and Topography of MEMS and Microstructures Complete 3-D Characterization Static and dynamic analysis and visualization are a critical part of the test

More information

Development of the next generation of 3D probing systems for the future co-ordinate measuring

Development of the next generation of 3D probing systems for the future co-ordinate measuring Development of the next generation of 3D probing systems for the future co-ordinate measuring machines and machine tools D.R. McMurtry Renishaw pic, New Mills, Wotton-under-Edge, Gloucestershire, GI72

More information

The Modal Shop, Inc. A PCB Group Company

The Modal Shop, Inc. A PCB Group Company The Modal Shop, Inc. A PCB Group Company Measurement Sector Systems Sector The TMS/PCB Relationship o PCB Focuses on Components and Sensors Accelerometers Microphones Pressure Sensors Signal Conditioning

More information

EDX-10 Series. Compact Recording System

EDX-10 Series. Compact Recording System 3-51 EDX-10 Series Compact Recording System Compact & lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls

More information

Calibration of Electromagnetic Flowmeter Using Advanced SCADA System

Calibration of Electromagnetic Flowmeter Using Advanced SCADA System FLOTEK.G 2017- Innovative Solutions in Flow Measurement and Control- Oil, Water and Gas August 28-30, 2017, FCRI, Palakkad, Kerala, India Calibration of Electromagnetic Flowmeter Using Advanced SCADA System

More information

THE ROBOT-MOUNTED OPTICAL CMM 3D SCANNERS FOR AUTOMATED INSPECTION

THE ROBOT-MOUNTED OPTICAL CMM 3D SCANNERS FOR AUTOMATED INSPECTION METROLOGY SOLUTIONS THE ROBOT-MOUNTED OPTICAL CMM 3D SCANNERS FOR AUTOMATED INSPECTION Accelerate your industrial inspection processes by bringing quality control as close to the part as possible. For

More information

Multifunction Calibrator

Multifunction Calibrator Multifunction Calibrator 5 Multifunction Calibrator Multifunction MC5 is the first of its kind modular ALL-IN-ONE multifunction calibrator. Within its compact and ergonomic case, MC5 provides calibration

More information

Artifact Calibration and Its Use in Calibrating 8.5 Digit DMMs

Artifact Calibration and Its Use in Calibrating 8.5 Digit DMMs Artifact Calibration and Its Use in Calibrating 8.5 Digit DMMs Author: Jack Somppi Product Marketing Manager Fluke Calibration, Everett, Washington, USA jack.somppi@flukecal.com Abstract Verifying that

More information

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34) is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates

More information

DATA SHEET DEA GLOBAL SILVER 09.XX XX.10

DATA SHEET DEA GLOBAL SILVER 09.XX XX.10 DATA SHEET DEA GLOBAL SILVER 09.XX.08-12.XX.10 Classic Performance Advantage Temperature Compensation Optional CLIMA CLIMA CLIMA Performance Environment Standard: 18 22 C Option CLIMA: 16 26 C Standard:

More information

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty Good Practice guide to measure roundness on roller machines and to estimate their uncertainty Björn Hemming, VTT Technical Research Centre of Finland Ltd, Finland Thomas Widmaier, Aalto University School

More information

DeFelsko PosiTector IRT Infrared Thermometer Probes

DeFelsko PosiTector IRT Infrared Thermometer Probes Management Procedure 2572 Revision: A Date Issued: April 12, 2018 Date Revised: Calibration Procedure DeFelsko PosiTector IRT Infrared Thermometer Probes Table of Contents 1 Introduction and UUC Performance

More information

Sensor Report: Hot Wire Anemometers

Sensor Report: Hot Wire Anemometers Introduction Sensor Report: Hot Wire Anemometers Paul Kawka Mechatronics GE330 3/17/03 Anemometry is the measurement of gas speeds, and a variety of different sensors have been developed to accurately

More information

THE ROBOT-MOUNTED OPTICAL CMM 3D SCANNERS FOR AUTOMATED INSPECTION

THE ROBOT-MOUNTED OPTICAL CMM 3D SCANNERS FOR AUTOMATED INSPECTION METROLOGY SOLUTIONS THE ROBOT-MOUNTED OPTICAL CMM 3D SCANNERS FOR AUTOMATED INSPECTION Accelerate your industrial inspection processes by bringing quality control as close to the part as possible. For

More information

11.0 Measurement of Spindle Error Motion

11.0 Measurement of Spindle Error Motion 11.0 Measurement of Spindle Error Motion 11.1 Introduction The major spindle error motion is caused by the alignment of the spindle rotational axis, the centerline of the tool holder and the centerline

More information

CFM/CMM Hot-Wire Thermoanemometer

CFM/CMM Hot-Wire Thermoanemometer User Manual CFM/CMM Hot-Wire Thermoanemometer with NIST-Traceable Calibration Model 20250-16 Max Min Flow Temp THE STANDARD IN PRECISION MEASUREMENT 2 Introduction The Digi-Sense CFM/CMM Hot-Wire Thermoanemometer

More information

Overview of Guildline s 6625A Resistance Measurement System

Overview of Guildline s 6625A Resistance Measurement System Overview of Guildline s 6625A Resistance Measurement System Overview The 6625A is a modular, customer specified Resistance Measurement System. Typically, the System is composed of a 6622A Series Bridge,

More information

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model User's Guide Heavy Duty Vane Thermo-Anemometer Model 407112 407112 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Specifications Circuit

More information

TABLE OF CONTENTS 3.0 QUALITY ASSURANCE PROGRAM TEST EQUIPMENT AND INSTRUMENTATION 5 ATTACHMENTS A PHOTOGRAPHS A-1 B VIBRATION TEST DATA B-1

TABLE OF CONTENTS 3.0 QUALITY ASSURANCE PROGRAM TEST EQUIPMENT AND INSTRUMENTATION 5 ATTACHMENTS A PHOTOGRAPHS A-1 B VIBRATION TEST DATA B-1 Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Vibration Resonance Search Test

More information

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model User Manual Heavy Duty Hot Wire CFM Thermo-Anemometer Model 407119 Introduction Congratulations on your purchase of the Extech 407119 Thermo-Anemometer. The 407119 measures air velocity, air volume, and

More information

EDX-10 Series. Compact Recording System

EDX-10 Series. Compact Recording System 3-49 EDX-10 Series Compact Recording System Compact, lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls

More information

LABMICROMETER. Pratt & Whitney UNIVERSAL LENGTH MEASURING SYSTEM. Measurement Systems, Inc.

LABMICROMETER. Pratt & Whitney UNIVERSAL LENGTH MEASURING SYSTEM. Measurement Systems, Inc. Pratt & Whitney Measurement Systems, Inc. The Standard of Accuracy Laser-Based LABMICROMETER is designed to provide the ultimate in user-friendly operation while delivering calibration-quality accuracy

More information

CyberGage 360 3D SCANNERS. One-Button Automation for 3D Scan Inspection.

CyberGage 360 3D SCANNERS. One-Button Automation for 3D Scan Inspection. CyberGage 360 One-Button Automation for 3D Scan Inspection. Powered by MRS Technology 3D SCANNERS Unprecedented speed, accuracy and one-button simplicity for non-contact automated 3D scanning inspection.

More information

LABVIEW APPLICATION: ENERGY LABORATORY UPGRADE

LABVIEW APPLICATION: ENERGY LABORATORY UPGRADE Session 3233 LABVIEW APPLICATION: ENERGY LABORATORY UPGRADE J. Howard Arthur Michael R. Sexton Mechanical Engineering Department Virginia Military Institute Lexington, VA 24450 Abstract This paper describes

More information

EE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

EE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications. Series High-Precision Air / Gas Velocity Transmitter for Industrial Applications The series air velocity transmitters were developed to obtain accurate measuring results over a wide range of velocities

More information

TESTING VISION CMMS AND THE INTERNATIONAL STANDARD, ISO

TESTING VISION CMMS AND THE INTERNATIONAL STANDARD, ISO TESTING VISION CMMS AND THE INTERNATIONAL STANDARD, ISO 10360-7 A TECHNICAL PRESENTATION FROM THE LEADING MANUFACTURER OF METROLOGY INSTRUMENTS EDUCATION Bulletin No. 2183 EDU-14004A-P Mitutoyo Institute

More information

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model User's Guide Heavy Duty Vane Thermo-Anemometer Model 407112 407112 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date

More information

Election Summary JACKSON COUNTY, MISSOURI GENERAL ELECTION NOVEMBER 4, 2014 (Official)

Election Summary JACKSON COUNTY, MISSOURI GENERAL ELECTION NOVEMBER 4, 2014 (Official) Election Summary JACKSON COUNTY, MISSOURI GENERAL ELECTION NOVEMBER 4, 2014 (Official) 207 OF 207 POLLS REPORTING Friday, November 7 2014 15:27:51 Non-Partisan FOR STATE AUDITOR Total: 73125 TOM SCHWEICH*

More information

STATE COLLEGE OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE MFGT INSTRUMENTATION AND CONTROLS

STATE COLLEGE OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE MFGT INSTRUMENTATION AND CONTROLS STATE COLLEGE OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE MFGT 220 - INSTRUMENTATION AND CONTROLS Prepared By: Daniel Miller Revised By: Daniel Miller 4/5/12 CANINO SCHOOL OF ENGINEERING

More information

Automated High Pressure Calibrator Model CPC 8000

Automated High Pressure Calibrator Model CPC 8000 Calibration Technology Automated High Pressure Calibrator Model CPC 8000 Mensor Data Sheet CPC 8000 02/2012 Applications Calibration of industrial pressure instruments Pressure transmitter manufacturers

More information

Pneumatic High-Speed Pressure Controller Model CPC3000

Pneumatic High-Speed Pressure Controller Model CPC3000 Calibration Technology Pneumatic High-Speed Pressure Controller Model CPC3000 02/2014 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture Calibration service companies

More information

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Pyromation Inc. Metrology Laboratory 5211 Industrial Road Fort Wayne, IN 46825-5152 Mr. Chris Moritz Phone: 260-484-2580 Fax: 260-482-6805 E-mail: chris@pyromation.com

More information

IND62 TIM CALIBRATION OF FREE-FORM STANDARD AND THEIR APPLICATIONS FOR IN-PROCESS MEASUREMENT ON MACHINE TOOLS

IND62 TIM CALIBRATION OF FREE-FORM STANDARD AND THEIR APPLICATIONS FOR IN-PROCESS MEASUREMENT ON MACHINE TOOLS IND62 TIM CALIBRATION OF FREE-FORM STANDARD AND THEIR APPLICATIONS FOR IN-PROCESS MEASUREMENT ON MACHINE TOOLS VÍT ZELENÝ, IVANA LINKEOVÁ, PAVEL SKALNÍK (LENGTH MEASUREMENT DEPARTMENT) 5th November 2014

More information

Contents 1 Measurement and Machine Tools An Introduction

Contents 1 Measurement and Machine Tools An Introduction Contents 1 Measurement and Machine Tools An Introduction... 1 1.1 Why the Need for Accurate and Precise Machine Tools a Brief History.... 1 1.2 The Early Historical Development of a Linear Measurements....

More information

FCRI Evaluation of Orifice Meter Validation System

FCRI Evaluation of Orifice Meter Validation System flotek.g Innovative Solutions in Flow Measurement and Control Oil, Water and Gas August 28-30, 2017, FCRI, Palakkad, Kerala, India FCRI Evaluation of Orifice Meter Validation System 1. ABSTRACT Hemant

More information

Ease of Use. Data at Your Fingertips LMS PHARMA

Ease of Use. Data at Your Fingertips LMS PHARMA LMS PHARMA Ease of Use LMS Pharma was designed with an ICON driven user interface which greatly simplifies the user experience. Color coded status and unique shaped ICONS enhance the already intuitive

More information

525A Temperature/ Pressure Calibrator

525A Temperature/ Pressure Calibrator 55A Temperature/ Pressure Calibrator Superior accuracy and functionality in an economical benchtop package Technical Data The Fluke 55A Temperature/ Pressure Calibrator gives you a workhorse combination

More information