MES1A, MES1B. Modbus TCP to Modbus ASCII/RTU Converters

Size: px
Start display at page:

Download "MES1A, MES1B. Modbus TCP to Modbus ASCII/RTU Converters"

Transcription

1 MES1A, MES1B Modbus TCP to Modbus ASCII/RTU Converters 1

2 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL USA Phone (815) General Fax (815) Website: European Headquarters B&B Electronics Westlink Commercial Park Oranmore, Co. Galway, Ireland Phone Fax Website: B&B Electronics Revised Jan 2014 Document: MES1A-B_R2_0814m.doc 2

3 CONTENTS WARRANTY... 7 CHAPTER 1: ABOUT YOUR MES1A/B CONVERTER... 9 FEATURES CHAPTER 2: HARDWARE OVERVIEW PACKAGE CHECKLIST INDICATORS, SWITCHES AND CONNECTORS Power LED Link LED Activity LED Reset Switch RS-422/485 Switch (MES1B only) Ethernet Port Connector DB-9M Serial Port Connector (MES1A only) RS-422/485 CONNECTOR (MES1B ONLY) POWER CONNECTOR CONNECTING THE HARDWARE CHAPTER 3: GETTING STARTED QUICKSTART Check the contents of your MES1A/B package. It should contain Set up the Hardware Software Installation Discover the MES1A/B on the Network Configure the MES1A/B Modbus Device Installation

4 USING THE DEVICE INSTALLER SOFTWARE System Requirements Installing the Device Installer Starting the Device Installer Discovering Devices Getting Device Details Connecting to the MES1A/B CHAPTER 4: CONFIGURING THE MES1A/B NAVIGATING THE CONFIGURATION MENU SAVING CONFIGURATION SETTINGS QUITTING WITHOUT SAVING RECONFIGURING TO FACTORY SETTINGS To Reconfigure the MES1A to Factory Settings: To Reconfigure the MES1B, to Factory Settings: Network/IP Settings IP Address Default Gateway Netmask Telnet Configuration Password SERIAL AND MODE SETTINGS Protocol Serial Interface MODEM/CONFIGURABLE PIN SETTINGS ADVANCED MODBUS PROTOCOL SETTINGS Slave Address / Unit ID Source Allow Modbus Broadcasts

5 Use MB/TCP 00BH/00AH Exception Responses Disable Modbus/TCP Pipeline Character Timeout Message Timeout Serial TX Delay after RX Swap 4x/0H to Get 3x/1x UNIT ID TO IP ADDRESS LOOKUP TABLE SETTINGS Close Idle TCP Sockets After Redundant Entry Retries After Add, Delete, Exit - Select Function Modbus Address From/To Slave IP Address CHAPTER 5: USING OTHER DEVICE INSTALLER FEATURES MANAGING DEVICE LISTS Creating a New Device List Saving Device Lists Opening Device Lists Device List Display Options Adding a Device Manually ASSIGNING AN IP ADDRESS (USING DEVICE INSTALLER) Using Device Installer to Assign an IP Address USING THE DEVICES DETAILS TAB UPGRADING FIRMWARE INSTALLING PRE-SAVED CONFIGURATION FILES Saving Setup Records Installing Setup Records

6 LOGGING SEARCH AND UPGRADE DATA USING PING USING HELP CHAPTER 6: MODBUS BASICS MODBUS ASCII/RTU MODBUS/TCP HINTS AND TIPS APPENDIX A: DEFAULT CONFIGURATION SETTINGS APPENDIX B: PRODUCT SPECIFICATIONS APPENDIX C: DIMENSIONAL DIAGRAMS APPENDIX D: SERIAL CONNECTIONS APPENDIX E: NETWORK CONNECTIONS

7 WARRANTY Limited Lifetime Warranty Effective for products of B&B Electronics Manufacturing Company shipped on or after May 1, 2013, B&B Electronics Manufacturing Company warrants that each such product shall be free from defects in material and workmanship for its lifetime. This limited lifetime warranty is applicable solely to the original user and is not transferable. This warranty is expressly conditioned upon proper storage, installation, connection, operation and maintenance of products in accordance with their written specifications. Pursuant to the warranty, within the warranty period, B&B Electronics Manufacturing Company, at its option will: 1. Replace the product with a functional equivalent; 2. Repair the product; or 3. Provide a partial refund of purchase price based on a depreciated value. Products of other manufacturers sold by B&B Electronics Manufacturing Company are not subject to any warranty or indemnity offered by B&B Electronics Manufacturing Company, but may be subject to the warranties of the other manufacturers. Notwithstanding the foregoing, under no circumstances shall B&B Electronics Manufacturing Company have any warranty obligations or any other liability for: (i) any defects resulting from wear and tear, accident, improper use by the buyer or use by any third party except in accordance with the written instructions or advice of the B&B Electronics Manufacturing Company or the manufacturer of the products, including without limitation surge and overvoltage conditions that exceed specified ratings, (ii) any products which have been adjusted, modified or repaired by any party other than B&B Electronics Manufacturing Company or (iii) any descriptions, illustrations, figures as to performance, drawings and particulars of weights and dimensions contained in the B&B Electronics Manufacturing Company s catalogs, price lists, marketing materials or elsewhere since they are merely intended to represent a general idea of the products and do not form part of this price quote and 7

8 do not constitute a warranty of any kind, whether express or implied, as to any of the B&B Electronics Manufacturing Company s products. THE REPAIR OR REPLACEMENT OF THE DEFECTIVE ITEMS IN ACCORDANCE WITH THE EXPRESS WARRANTY SET FORTH ABOVE IS B&B ELECTRONIC MANUFACTURING COMPANY S SOLE OBLIGATION UNDER THIS WARRANTY. THE WARRANTY CONTAINED IN THIS SECTION SHALL EXTEND TO THE ORIGINAL USER ONLY, IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND ALL SUCH WARRANTIES AND INDEMNITIES ARE EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION (I) THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY AND (II) ANY WARRANTY THAT THE PRODUCTS ARE DO NOT INFRINGE OR VIOLATE THE INTELLECTUAL PROPERTY RIGHTS OF ANY THIRD PARTY. IN NO EVENT SHALL B&B ELECTRONICS MANUFACTURING COMPANY BE LIABLE FOR LOSS OF BUSINESS, LOSS OF USE OR OF DATA INTERRUPTION OF BUSINESS, LOST PROFITS OR GOODWILL OR OTHER SPECIAL, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES. B&B ELECTRONIC MANUFACTURING COMPANY SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS, WARRANTIES OR INDEMNITIES MADE BY ANY OTHER PERSON, INCLUDING WITHOUT LIMITATION EMPLOYEES, DISTRIBUTORS, RESELLERS OR DEALERS OF B&B ELECTRONIC MANUFACTURING COMPANY WHICH ARE INCONSISTENT WITH THE WARRANTY, SET FORTH ABOVE. 8

9 CHAPTER 1: ABOUT YOUR MES1A/B CONVERTER Thank you for purchasing an MES1A or MES1B Modbus TCP to Modbus ASCII/RTU Converter! Like all B&B Electronics products, this product has been manufactured to the highest standards of quality and performance to ensure your complete satisfaction. MES1A and MES1B Modbus TCP to Modbus ASCII/RTU Converters are easy-to-use, cost-effective solutions for connecting new and existing Modbus ASCII/RTU serial devices to TCP/IP networks. The MES1A provides this connection for Modbus devices with RS-232 interfaces; the MES1B facilitates Modbus devices with RS-422 four-wire point-to-point interfaces, or RS-485 four or two-wire multi-drop bus connections. MES1A and MES1B Converters MES1A Converters allow new and legacy Modbus ASCII/RTU slave devices with RS- 232 serial ports to operate on a TCP/IP network as full Modbus TCP slaves. All Modbus TCP devices on the network can share access to the Modbus ASCII/RTU device. MES1B Converters allow Modbus/RTU slave devices with RS-422/485 interfaces to operate on a TCP/IP network as full Modbus TCP slaves. All Modbus devices on an RS-485 bus can be connected to the TCP/IP network via the MES1B, allowing them all to be accessed by Modbus TCP/IP devices on the network. Traditional Modbus ASCII/RTU master devices also can be connected to TCP/IP networks using the MES1A/B, making the device appear to be a full Modbus TCP 9

10 master on the network. It can directly access Modbus TCP slave devices. It also can access other Modbus ASCII/RTU slaves that are connected to the network via other MES1A/B Converters, as if it is talking directly to a Modbus ASCII/RTU slave. FEATURES Converts Modus ASCII/RTU to Modbus/TCP Small, economical and configurable MES1A supports TD, RD and GND RS-232 lines MES1B supports TDA(-), TDB(+), RDA(-), RDB(+) RS-422/485 lines LEDs on network connection indicate link integrity and data transfer activity 10/100 Mbps auto-detecting operation Removable screw terminal strips for power supply Removable screw terminal strips for RS-422/485 connection (MES1B) Device Installer user interface software included DIN rail mountable 10

11 CHAPTER 2: HARDWARE OVERVIEW PACKAGE CHECKLIST MES1A/B Modbus ASCII/RTU to Modbus TCP Converters are shipped with the following items included: the MES1A or MES1B module a printed version of this user manual a printed version of the MES1A/B Quick Start Guide a CD-ROM disc with o o o Device Installer software this manual in pdf format a Quick Start guide in pdf format 11

12 INDICATORS, SWITCHES AND CONNECTORS POWER LED The Power LED illuminates (red) immediately on power up indicating that 10 VDC to 30 VDC power is present on the Power Supply terminals. (Typically 12 VDC is used.) LED Indicators on the MES1A LINK LED When the Link LED located on the Ethernet jack is illuminated it indicates that a connection (link integrity) has been established between the converter and the network. Its color is green if connected to a 100BaseT network; orange if connected to a 10BaseT network. It turns orange briefly during the power up process. 12

13 ACTIVITY LED When the Activity LED located on the Ethernet jack is flashing (green) it indicates data is being sent across the network. This LED turns orange briefly during the power up process. LED Color/Status Function Power Red Power applied Link Activity Orange Green Green (Blinking) Orange Bootup, 10BaseT 100BaseT Data on the network Bootup LED Status Table RESET SWITCH The Reset switch is accessible on the top edge of the MES1A/B (same edge as the power supply connector) through a small hole in the MES1A/B enclosure. It allows you to reset the MES1A/B by inserting a small tool through the hole and pressing the momentary switch for about 1 second. The MES1A/B restarts with its last saved configuration settings. 13

14 RS-422/485 SWITCH (MES1B ONLY) The RS-422/485 switch allows you to set the MES1B Converter for RS-422/485 fourwire or RS-485 two-wire operation. When the switch is in the left position, the MES1B operates in RS- 422/485 four-wire mode. When the switch is in the right position, the MES1B operates in the RS- 485 two-wire mode. ETHERNET PORT CONNECTOR The Ethernet Port connector is a standard RJ-45 receptacle that allows the converter to be connected to an Ethernet network. Two indicator LEDs (described above) are built into the RJ-45 connector. DB-9M SERIAL PORT CONNECTOR (MES1A ONLY) The Serial Port Connector on the MES1A is a DB-9 male connector (configured as a DTE) supporting RS-232 serial communications including TD (Pin 3), RD (Pin 2) and GND (Pin 5) signal lines. If the Modbus device you are connecting to the MES1A is configured as a DCE you will use a straight-through serial cable. If the Modbus device is configured as a DTE, use a null modem cable. Refer to Appendix D for connection pin-outs. 14

15 RS-422/485 CONNECTOR (MES1B ONLY) The RS-422/485 connector on the MES1B is a five position removable terminal block with screw downs. The connector provides screw connections for: Terminal 1 - RDB(+) Terminal 2 - RDA(-) Terminal 3 - TDB(+) Terminal 4 - TDA(-) Terminal 5 Ground MES1B Serial Connector 15

16 RS-422/485 FOUR-WIRE MODE When the MES1B is configured to operate in RS-422/485 four-wire mode (RS- 422/485 switch in the left position) its receive terminals are connected to the transmit terminals of the Modbus device it is communicating with. Its transmit terminals are connected to the receive terminals of the Modbus device it is communicating with. RS-422/485 Four-Wire Connection 16

17 RS-485 TWO-WIRE MODE When the MES1B is configured to operate in RS-485 two-wire mode (RS-422/485 switch in the right position) the two-wire RS-485 two-wire communications cable pair is connected to Terminals TDB and TDA. The communications cable ground/shield is connected to GND. RS-485 Two-Wire Connection No jumpers are required to bridge the transmit and receive lines in two-wire mode. 17

18 POWER CONNECTOR The Power Connector is a removable two-position screw terminal block with screw down. The MES1A/B requires between 10 VDC and 30 VDC (3.6 Watts). Typically a 12 VDC power adapter is connected to the terminal block via bare wires. The terminal block can be unplugged to remove the converter from service. CONNECTING THE HARDWARE MES1A/B Power Connector The MES1A is connected to its Modbus device via a DB-9M connector and an RS-232 cable. The MES1A is configured as a DTE. If the connected Modbus device is configured as a DCE, use a straight-through cable. If the connected Modbus device is configured as a DTE, use a null modem cable. Always check the interface specifications of the Modbus device to determine whether it is a DTE or DCE before connecting. The MES1B is connected to its Modbus device via the RS-422/485 terminal block. In RS-422/485 four-wire mode a cable containing two pairs and a ground/shield is used. In RS-485 two-wire mode a cable containing one pair and a ground/shield is used. Power is supplied to the converter via the power supply terminal block. 18

19 Typically, the MES1A/B is connected to the network via a hub switch or router using standard straight-through CAT-5 cable. (If you are connecting the MES1A/B directly to a PC s network interface a crossover Ethernet cable is required.) MES1A Connections MES1B Connections 19

20 CHAPTER 3: GETTING STARTED QUICKSTART The following section is a quick, step-by-step procedure that will assist you to get started configuring the MES1A/B. Additional details on how to use the Device Installer software to discover and connect to devices is included in the section following this one. MES1A/B configuration details are included in Chapter 4. Check the contents of your MES1A/B package. It should contain The MES1A or MES1B unit A printed version of this user manual A printed version of the MES1A/B Quick Start Guide Software CD with Device Installer software, this manual, Quick Start guide SET UP THE HARDWARE Connect the MES1A/B to the network using an Ethernet cable. Connect your PC to the network Connect a 12 VDC power supply (not included) to the MES1A/B and apply power. (10 to 30 VDC, 3.6 Watts.) SOFTWARE INSTALLATION Insert the software CD and it should auto-start into the installation wizard. Follow the on-screen installation wizard to install the Device Installer software. 20

21 DISCOVER THE MES1A/B ON THE NETWORK Open the Device Installer software. It should detect the MES1A/B and display XPort in the third level of the Devices Tree. If you are using an older version of the discovery tool with newer models of the MES1A/B, it will still discover the device, but it will identify it as Unknown. Expand the Devices Tree and click the device IP Address. Select the Telnet Configuration tab, then click Connect. When the Modbus/TCP to RTU Bridge, MAC address and Software version information appears, Press Enter to go into Setup Mode. CONFIGURE THE MES1A/B To change the IP Address, Default Gateway or Netmask, type 1. To configure Master/Slave and serial Interface settings, type 2. Do not change any configuration settings in section 3. To configure Modbus/TCP settings, type 4. To configure Modbus Master settings, type 5. To save your settings to the MES1A/B, type S. MODBUS DEVICE INSTALLATION Connect the Modbus device to the serial interface on the MES1A/B using the correct cabling: MES1A is a DTE: Use a straight through serial cable if the Modbus device is a DCE; null modem if device is DTE. MES1B: Four-wire for RS-422, Two-wire for RS-485, Set RS-422/485 switch. 21

22 Your Modbus device should now be operational on the network. Note: The MES1A/B can be reset (rebooted) by pressing the Reset switch for one second. Reset switch is accessed through a small hole in the top of the enclosure. USING THE DEVICE INSTALLER SOFTWARE This section provides more detailed information on how to install and use the Device Installer software. Device Installer is used to set up and configure the MES1A/B on a network. It detects all MES1A/Bs on the network and allows you to configure the network and serial port settings. It also allows you to monitor the MES1A/B and verify its status. SYSTEM REQUIREMENTS Windows XP, Windows 2000, Windows NT4.0 (with service pack 6.0a or later), Windows ME, or Windows 98 Internet Explorer 5.01 or later 30 MB hard drive space 64 MB RAM INSTALLING THE DEVICE INSTALLER Note: Device Installer requires Microsoft.NET software to operate. To install the Device Installer software: 1. Insert the CD included with your MES1A/B into the CD ROM drive of your PC. 22

23 2. The installation should launch automatically. If not: a. Click Start on the Task Bar and select Run b. Type in [CD drive letter]:\launch.exe 3. When the Device Installer Setup Wizard dialog box appears, click Next to open the Select Installation Folder dialog box. 4. Accept the suggested installation folder or click Browse to select a different installation folder. 5. Click Next to open the Confirm Installation dialog box. 6. Click Next to begin the installation. When finished, the Installation Complete dialog box appears. STARTING THE DEVICE INSTALLER Run the Device Installer from the Start, Programs, Lantronix, DeviceInstaller menu. DISCOVERING DEVICES When Device Installer opens it automatically scans the network for MES1A/B devices. Any of the following steps will initiate a manual search for devices: Click the Search icon On the Device menu, click Search Press the F5 function key When discovered for the first time, any MES1A/B devices present are listed in the Devices Tree pane and Device List pane as XPort and XPort IAP respectively. (XPort is the name of the internal module of the MES1A/B.) If you are using an older version of the discovery tool with newer models of the MES1A/B, it will still discover the device, but it will identify it as Unknown. 23

24 The Devices Tree shows a hierarchy including any network bridges under which the MES1A/B is found. The Device List pane is a table showing: Device Type Device Name Group IP Address Hardware (MAC) Address Status The Device Installer Main Window GETTING DEVICE DETAILS The Device Installer provides a variety of information about the MES1A/B under the Device Details tab. To access the Device Details tab: 1. Expand the Device Tree by clicking the + symbol next to XPort. Keep expanding until the IP Address of the MES1A/B appears. 2. Click the IP Address on the Device Tree. The Device Details tab appears where the Device List was. 24

25 Device Details Tab Note: The Web Configuration tab is not used with the MES1A/B. CONNECTING TO THE ME S1A/B Before configuration can occur you must set up a telnet connection with the MES1A/B to access the Configuration Menu. You can access the Configuration Menu using a standard telnet window, or use the telnet implementation within the Device Installer software. The Device Installer option provides an all-in-one user interface for working with the MES1A/B To connect: 3. Select the Telnet Configuration tab. The tab shows the IP Address of the MES1A/B and the Port Number used to communicate with it via telnet. The rest of the window is blank. 4. Click Connect to connect to the MES1A/B. When a connection is established the following window appears, which contains information on the MAC address and Software version of the MES1A/B. 25

26 Press Enter to go into Setup Mode The background color of the window remains white for five seconds, then changes to gray when it times out. 5. Press the Enter key within five seconds to go into Setup Mode or it will time out (and you will have to click Clear and repeat the process). The MES1A/B Configuration Menu appears. Telnet Configuration Tab with Settings Refer to Chapter 4 for configuration details. 26

27 CHAPTER 4: CONFIGURING THE M ES1A/B Configuration of the MES1A/B is accomplished from the Configuration Menu, which is accessed via a standard telnet window, or through the telnet implementation within the Device Installer software. Note: The Web Configuration tab is not used with the MES1A/B. Telnet Configuration Tab 27

28 NAVIGATING THE CONFIGURATION MENU On initial power-up there are four sections in the MES1A/B configuration menu. A fifth menu item appears if you are configuring a Modbus Master device. The menu items are: 6. Network/IP Settings 7. Serial & Mode Settings 8. Modem/Configurable Pin Settings 9. Advanced Modbus Protocol Settings The following menu item 5) appears if the MES1A/B is configured as a Modbus Master in section 2) Serial Protocol 10. Unit ID to IP Address Table Each section of the configuration menu includes several parameters. 11. Begin the configuration by typing the menu section number at the Select Command or parameter set (1..4) to change: prompt. The first configuration parameter of the section will appear at the bottom of the pane. The current setting is shown in brackets. Example: 28

29 Setting the IP Address 12. To change the parameter, type in a new value, then press Enter. If you wish to leave the parameter as it was, simply press Enter. A prompt for the next parameter will appear. 13. When all parameters in the currently selected section are complete you will again be prompted to select a menu item. Select another section and continue the configuration process. SAVING CONFIGURATION SETTINGS When all categories have been configured you must save your configuration to the MES1A/B. To Save the configuration settings to the MES1A/B, at the Select Command or parameter set (1..4) to change: prompt type S. QUITTING WITHOUT SAVING To Quit the configuration session without saving, type Q. The background color will change to gray and the MES1A/B will re-start without updating the configuration settings. 29

30 RECONFIGURING TO FACTORY SETTINGS The MES1A and MES1B come from the factory preconfigured for correct operation with their respective interfaces. The following procedure describes how you can return the MES1A and MES1B to their original factory settings. TO RECONFIGURE THE MES1A TO FACTORY SETTINGS: Type D at the Select Command or parameter set (1..4) to change: prompt. The Configuration Menu is updated with the new settings displayed. TO RECONFIGURE THE MES1B, TO FACTORY SE TTINGS: 14. Type D at the Select Command or parameter set (1..4) to change: prompt. 15. Type 2 to enter the Serial & Mode Settings section and set the Serial Mode for RS-485 Two-Wire (see the next section for details). 16. Type 3 to enter the Modem/Configurable Pin Settings section and set CP1 to RS-485 Enable Wire (see the next section for details).. See the following sections for details on how to set Serial & Mode Settings and Modem/Configurable Pin Settings. NETWORK/IP SETTINGS In the Network/IP Settings section of the Configuration Menu you can configure: IP Address of the MES1A/B Default Gateway Netmask Telnet Configuration Password 30

31 IP ADDRESS Every device connected to a TCP/IP network must have a unique IP Address. This includes every MES1A/B. However, there is more than one way to set up an IP address for the MES1A/B DHCP The MES1A/B is shipped with a default IP address of This configures the converter to obtain an IP address via DHCP (Dynamic Host Configuration Protocol) from a DHCP server on the network when the MES1A/B boots up. If a DHCP server is available to respond to the DHCP request, the MES1A/B will receive an IP address, gateway address and subnet mask from the server. A DHCP-generated IP address will appear in the Device Tree, Device List and at the top of the Telnet Configuration tab, but it will not be displayed in the IP Address field of the Network/IP Settings section of the Configuration Menu. Network/IP Settings Menu AUTO-IP If a DHCP server is NOT available on the network, the MES1A/B will revert to Auto-IP and generate its own IP address in the xxx.xxx range. STATIC IP ADDRESS The IP address of the MES1A/B can be changed via the Telnet Configuration Menu interface. 31

32 To determine an appropriate static IP address, consult your network administrator. The Device Installer Help feature also provides some useful information related to IP addressing. 17. At the Select Command or parameter set (1..4) to change: prompt, type At the IP Address (000)prompt o o To keep the current setting, press Enter To change the IP address, type the first octet Press Enter to accept the change Repeat for all octets 19. Press Enter to accept the new IP address After the new settings have been accepted they will appear in the Configuration Menu. After the Configuration has been saved to the MES1A/B, the new settings will appear in the Device Details tab. The IP Address can also be changed from the Device Installer menu. See Chapter 5 for details. DEFAULT GATEWAY A Default Gateway address is only required if your MES1A/B must communicate with devices on remote TCP/IP networks through a router or gateway. The default value for this parameter is ---not set---. If you DO NOT require remote communication, type N or just press Enter at the Set Gateway IP Address (N) prompt. 32

33 If you DO require remote communication through a router or gateway, type Y. The Gateway IP Address: (000) prompt appears. Enter the IP address of the default gateway within your local network by typing each address octet followed by pressing Enter. After the new settings have been accepted they will appear in the Configuration Menu. After the Configuration has been saved to the MES1A/B, the new settings will appear in the Device Details tab. NETMASK Typically you will type N, or just press Enter to cause the MES1A/B to automatically use the standard Netmask appropriate for the IP address being used. The default value for this parameter is ---not set---. To change the Netmask setting 20. Press Enter to keep the current setting 21. Press Y to change the setting 22. At the prompt type in four octets representing the new Netmask. After the new settings have been accepted they will appear in the Configuration Menu. After the Configuration has been saved to the MES1A/B, the new settings will appear in the Device Details tab. For more information or direction on the netmask you may require, consult your network administrator. TELNET CONFIGURATION PASSWORD You can set up a Telnet Configuration Password to control unauthorized access to the Telnet Configuration interface. 23. Type Y. The Enter New Password: prompt appears. 33

34 24. Type in a password. The words Telnet config password set appears in the 1) section of the configuration menu. The default value for this parameter is N (for Not Set). Warning: Do not forget your password if used. There is no easy way to get into the unit for configuration once you forget your password. SERIAL AND MODE SETTINGS In the Serial and Mode Settings section of the Configuration Menu you can configure: the serial Protocol to be used with your Modbus device the Serial Interface type and communications parameters Serial & Mode Settings Menu To configure Serial and Mode Settings, type 2 at the Select Command or parameter set (1..4) to change: prompt. The Attached Device prompt appears. PROTOCOL Protocol parameters must be set to match the type of Modbus device (master or slave) connected to the serial side of the MES1A/B device, and the type of Modbus protocol (ASCII or RTU) that will be used. ATTACHED DEVICE Modbus devices operate as either Masters (polling Slaves) or Slaves (responding to polls from Masters). An example of a Modbus master is a computer running HMI (human machine interface) software. Examples of Modbus slaves are controllers, remote terminal units (RTU) or programmable logic controllers (PLC). 34

35 To configure the type of Attached Device: 25. At the Attached Device (1=Slave 2=Master)(1) prompt o To keep the current setting, press Enter o To select Slave, type 1 o To select Master, type To accept changes, press Enter Note: When Master mode is selected a fifth item (Unit ID -> IP Address Table is added to the Configuration Menu. SERIAL PROTOCOL Modbus devices communicate in either of two Serial Protocols: ASCII or RTU. Modbus/ASCII protocol is slower and uses two ASCII characters to represent each 8 bit data byte. Modbus/RTU uses 8 bit binary data characters. The MES1A/B must be configured to use the same protocol used by the attached Modbus device. To configure the type of Serial Protocol 27. At the Serial Protocol (1=Modbus/RTU 2=Modbus/ASCII) (1) prompt o To keep the current setting, press Enter o To select Modbus/RTU, type 1 o To select Modbus/ASCII, type To accept changes, press Enter 35

36 SERIAL INTERFACE Serial Interface parameters include the type of interface and the data rate/format of the data. The MES1A/B must use the same type of interface and serial parameters as that of the Modbus device it is connected to. MES1A SERIAL INTERFACE Since the MES1A is designed with an RS-232 interface, its default Interface Type is RS-232. Although RS-422/485 four-wire and RS-485 twowire options are given in the configuration menu, reconfiguring the MES1A for anything other than RS-232 will prevent the device from operating correctly. MES1B SERIAL INTERFACE The MES1B is designed with an RS-422/485 interface and can be configured for fourwire operation or two-wire operation. Although RS-232 option is provided in the configuration menu, reconfiguring the MES1B for RS-232 will prevent the device from operating correctly. To configure Interface Type parameters: 29. At the Interface Type (1=RS232 2=RS422/RS485+4-wire 3=RS485+2-wire) (3) prompt: o To keep the current setting, press Enter o To select RS-422/RS-485 four-wire, type 2 o To select RS-485 two-wire, type To accept changes, press Enter 36

37 WHEN RS-422/485 FOUR-WIRE OPERATION IS SELECTED: When RS-422/485 four-wire operation is selected the RS-422/485 switch on the MES1B must be in the left position. WHEN RS-485 TWO-WIRE OPERATION IS SELECTED: CP1 (configured in the next section under Modem/Configurable Pin Settings) must be enabled to ensure Send Data control is implemented. The RS-422/485 switch on the MES1B must be in the right position. The multidrop bus is connected to Terminals 3 [DataB(+) to TDB(+) terminal] and 4 [DataA(-) to TDA(-) terminal]. No jumpers are required to bridge transmit and receive lines on the terminal block SERIAL PARAMETERS MES1A/B Serial Parameters must be set up to match the parameters of the Modbus device connected to its serial interface. MES1A/B Serial Parameter options include: Data rates from 300 bps to bps 7 or 8 data bits No, Even or Odd parity 1 or 2 stop bits. To configure Serial Parameters: 31. At the Enter serial parameters (9600,8,N,1)prompt o To keep the current setting, press Enter 37

38 o To change the serial parameters, type in new parameters in the format 9600,8,N,1 32. To accept changes, press Enter MODEM/CONFIGURABLE PIN SETTINGS There is only one configurable setting required in the Modem/Configurable Pin Settings section of the Configuration Menu. When configuring an MES1B for RS-485 two-wire operation, the CP1 parameter must be set for RS485 Enable to ensure Send Data Control is implemented. No configuration is required in this section for MES1A converters. To configure RS485 Enable in the Modem/Configurable Pin Settings section: 33. Type 3 at the Select Command or parameter set (1..4) to change: prompt. The CP1 Function prompt appears. 34. Type 4 to select RS485 Enable 35. To accept the change, press Enter 36. Press Enter three more times to exit the Modem/Configurable Pin Settings section of the Configuration Menu. ADVANCED MODBUS PROTOCOL SETTINGS In the Advanced Modbus Protocol Settings section of the Configuration Menu you can configure: whether the Slave Address is fixed or used as received whether to Allow Modbus Broadcasts whether to Use MB/TCP 00BH/00AH Exception Responses whether to Disable Modbus/TCP Pipeline 38

39 Character Timeout values Message Timeout values Serial TX delay after RX values whether to Swap 4x/0H to get 3x/1x register conversions Advanced Modbus Protocol Settings Menu SLAVE ADDRESS / UNIT ID SOURCE All devices connected to a TCP/IP network require a unique IP address. Each MES1A/B Converter has a unique IP address on the network, allowing messages to be directed to it. However, when multiple Modbus/RTU devices are connected to the RS-485 bus of an MES1B there must be a way to address them individually. Standard Modbus/RTU fields are encapsulated inside Modbus/TCP messages. Modbus/RTU s Slave Address field is called the Unit ID in Modbus/TCP. The Unit ID is used to specify a particular Modbus/RTU device on the serial side of the MES1A/B. When the MES1A/B receives a message (sent to its IP address), it looks at the Unit ID field of the message and passes the message to the specified slave. 0 FOR AUTO Setting the Slave Address field to 0 allows the MES1A/B to use the Unit ID received from a Modbus master to direct messages to a specific slave address. The MES1A/B receives the Unit ID number on the Modbus/TCP side and passes it along as the Slave Address on the serial side of the converter. 39

40 1 255 Unfortunately, some early Modbus/TCP products assumed that each IP address would have only one slave. These products always set their Unit ID to 0 (relying on the IP address only to address the slave). The lack of an appropriate Unit ID presents a problem for the MES1B. It must include a Slave Address in its messages to Modbus/RTU slaves. To overcome this problem, the MES1A/B Slave Address field can be set to the address of one Modbus/RTU slave (any number in the range of 1 to 255). This limits the number of slaves that can be connected to the MES1A/B to one, but ensures that when any message for the MES1A/B s IP address is received (regardless of its Unit ID), it is passed along to the slave. To configure the Slave Address field: If Modbus TCP masters on your system use appropriate Unit ID addresses, select 0. You will be able to connect multiple Modbus/RTU slaves with RS-485 interfaces to an MES1B. If any Modbus TCP masters on your system use 0 for all Unit ID fields, select a slave address that matches the Modbus/RTU slave attached to your MES1A/B. You will not be able to connect multiple slaves to the RS-485 multidrop bus. ALLOW MODBUS BROADCASTS If you configured the Slave Address for any number between 1 and 255 the Allow Modbus Broadcasts does not appear in the menu. When a Modbus/RTU slave receives a slave address of 0 it interprets this as a broadcast message. All slaves accept the message. Setting the Allow Modbus Broadcasts (1=Yes, 2=No)to No reassigns a Unit ID of 0 from a Modbus TCP master as a slave address 1. This ensures that a Unit ID is not interpreted as a broadcast message. 40

41 USE MB/TCP 00BH/00AH EXCEPTION RESPONSES In Modbus/RTU, when a master initiates a query it expects to receive a response. If it does not receive one within an acceptable length of time it interprets the silence as an indication that a communications error has occurred. Because delays in TCP/IP networks are not predictable, problems can occur. To address this, Modbus/TCP defines two exception codes that can be enabled to be sent in the event of a communications failure. 1 = NO If Use MB/TCP 00BH/00AH Exception Responses (1=No 2=Yes)is disabled (1=No), the MES1A/B operates like a Modbus/RTU slave. It answers timeouts, un-configured slave addresses and CRC errors with silence. 2 = YES If the Use MB/TCP 00BH/00AH Exception Responses (1=No 2=Yes)is enabled (2 = Yes), the MES1A/B will return the following codes under any of the conditions described: 0A (HEX) - PATH UNAVAILABLE If it receives a query from a Modbus master in which the Unit ID specifies a Slave Address not listed in the Unit ID to IP Mapping Table If the TCP socket fails to open. 0B (HEX) - TARGET DEVICE FAILED TO RESPOND If the slave did not answer, or the answer contained a CRC error If a TCP socket is open, but no response is received within the defined message timeout period 41

42 If a TCP socket is open, but the remote Modbus TCP slave/server returned exception 0B (hex) DISABLE MODBUS/TCP PIPELINE Typically a Modbus master issues a query and waits for a response before issuing another. However, when using Modbus/TCP, multiple queries can be issued and the MES1A/B will buffer them in a pipeline. The MES1A/B can fetch each query one at a time, and respond. In some situations this is useful, but in others the sequence of query/response can get out of sync (especially if any queries or responses are lost). The Disable Modbus/TCP Pipeline setting allows you to decide how you want the system to operate. Setting this field to 1 = No configures the MES1A/B to allow pipeline operation. This is considered the safest default setting. It is recommended that you choose this option unless you are experiencing problems. Setting this field to 2 = Yes configures the MES1A/B to always fetch the latest request from the TCP buffer (discarding all older requests). CHARACTER TIMEOUT Although Modbus/RTU specifies a 3.5 character time out period between characters, the Character Timeout field allows you to set a custom value for this field. If you set this field to 0, the MES1A/B will automatically calculate a minimum timeout based on the baud rate being used. Although you can set this field to any value between 1 milliseconds and 6959 milliseconds, a recommended safe value for general use is about 50 milliseconds (which is the default value). 42

43 MESSAGE TIMEOUT The Message Timeout field allows you to set the timeout period for responses from a connected slave to any value between 200 milliseconds and milliseconds. The default value is 5000 milliseconds. SERIAL TX DELAY AFTER RX When the MES1A/B receives a request from a master it relays the request to the Modbus slave connected to the MES1A/B s serial connection. When the slave responds a timer is triggered and, after the delay time configured in the Serial TX Delay after TX field, the next master request is allowed to pass through the serial connection to the slave. When using 2-wire RS-485 connections, this delay value can be set to ensure that RS-485 devices have time to disable their drivers and enable their receivers to receive the next request. Typically this is not a concern and the default value is 0. The delay can be set to a maximum of 1275 milliseconds. SWAP 4X/0H TO GET 3X/1X This field allows you to configure the MES1A/B to convert holding register (4x) data to input register (3x) data, and convert coil (0x) data to contact (1x) data. This is useful when connecting to Modicon I/O scanners. UNIT ID TO IP ADDRESS LOOKUP TABLE SETTINGS The Configuring Unit ID to IP Address Table Settings section of the Configuration Menu becomes available if the MES1A/B has been configured as a Modbus Master in Configuration Menu section 2). From Configuration Menu section 5) you can configure: whether to Close Idle TCP Sockets after a specified number of seconds whether to enable Redundant entry retries after a specified number of seconds the Unit ID to IP Address Lookup Table 43

44 Unit ID -> IP Address Table Settings Menu CLOSE IDLE TCP SOCKE TS AFTER The Close Idle TCP Sockets After field allows you to configure whether a socket is held open, or the number of seconds to hold the last socket open. If you configure this field for 0 it hold a single socket open to the last remote Modbus TCP slave accessed If you configure this field for any value between 3 and 60 seconds, it will close the last socket after the configured length of idle time. REDUNDANT ENTRY RETRIES AFTER The Redundant Entry Retries After field allows you to disable redundant retries or set a maximum length of time for retries. If you configure this field for 0 is disables the feature. If you configure this field for any value between 15 seconds and 60 seconds it will set the retry period to the configure time. ADD, DELETE, EXIT - SELECT FUNCTION The Add, Delete, Exit - Select Function field is the starting point for managing entries in the IP Address Table. Type A to add an entry. The Modbus addr from prompt appears. Type D to delete an entry. The Delete entry number prompt appears. Type E to exit. 44

45 MODBUS ADDRESS FROM/TO Configuring these fields sets up the range of Modbus slave addresses that will be forwarded to the IP address (that you will configure in the next step). The prompt: Modbus addr from (1) indicates that no slave addresses have been added to the list so far. If other slave addresses have already been configured, the number will reflect the first available slave address number. 37. Press Enter to accept (1) as the first slave address number, or type in the number you prefer. After you press Enter, the Modbus Address To prompt appears. 38. Type in an slave address number that reflects the range of slaves that will be found at the IP address that will be entered in the next step. When you press Enter the Slave IP address prompt appears. SLAVE IP ADDRESS Type in the four octets of the IP address of the slaves being addressed. If you configure the last octet as 000 the MES1A/B will use the Slave Address/Unit ID of the slave as part of the IP address. This allows a Modbus/RTU master (connected through the MES1A/B) to access up to 255 remote Modbus TCP slaves. If you configure the last octet for a number between 1 and 254, all slave polls in this group will be sent to the same IP address. 45

46 CHAPTER 5: USING OTHER DEVICE INSTALLER FEATURES In addition to the capabilities already mentioned, the Device Installer software provides other important and useful features. This section provides a brief overview of those features. For more information, access the Help files from the main menu. Device Installer features which are not used or supported by the MES1A/B include: Console Mode (via Serial port) configuration Recover Firmware (Tools menu, Advanced selection) Web Configuration MANAGING DEVICE LISTS This section included information on how to: Create a New Device List Save a Device List Open a Device List Configure Device List Display Options CREATING A NEW DEVICE LIST To create a new Device List, on the File menu, select New. The Device Installer software will create a new list but will not initiate a search to discover devices on the network. To initiate a search, select Search On the Device menu, click the Search Icon or press F5. 46

47 SAVING DEVICE LISTS After a list of MES1A/B devices has been discovered on the network, you can save the list, including details such as the Device Name, Group, Comments and IP Address. To save a Device List, On the File menu, select Save or Save As, type in a file name of your choice and click Save. Note: The configuration of the MES1A/B is NOT saved using this method. To store the configuration in the MES1A/B, on the Telnet Configuration Menu, set up the configuration, then type S at the Default settings, Save, Quit without Save prompt. To store the configuration in a Setup Record file see the procedure later in this chapter. OPENING DEVICE LISTS To open an existing Device List, on the File menu, select Open. In the Open dialog box that appears, select or type in a file name and click Open. The MES1A/B will search for all devices listed in the Device List file and display them in the Devices Tree. Devices not listed in the Device List file will not be shown. To discover other devices not already on the list you must initiate a search. DEVICE LIST DISPLAY OPTIONS Device Installer provides several options for displaying devices in the Device Tree and List. 47

48 DISPLAY DEVICES USING ICONS On the View menu, select Device List, then select Icons. Device List Icon View DISPLAY THE HARDWARE (MAC) ADDRESS On the View menu, select Device Node Text, then select Hardware Address. Device Node Hardware Address View 48

49 DISPLAY THE DEVICE NAME On the View menu, select Device Node Text, then select Name. Device Node Name View ADDING A DEVICE MANUALLY Although you will typically discover MES1A/B devices on the network using the Search tool, you can also add a device to the network manually. To do so you must know the IP address of the device. Add Device Dialog Box To manually add a device to the Device List: 39. On the Device menu, select Add Device. 40. In the Add Device dialog box, type the IP address of the device. 41. Click OK If a device with that IP address is not found on the network a dialog box will appear indicating Device at [IP address] was not found! 49

50 If a device is found it will be listed in the Device Tree and the Device Details tab for the device appears. ASSIGNING AN IP ADDRESS (USING DEVICE INSTALLER) The MES1A/B can obtain its IP address in several ways: Via DHCP when it is first connected to the network (See Chapter 4) By changing the IP address from the Telnet Configuration Menu (See Chapter 4) Using the Assign IP feature of the Device Installer software USING DEVICE INSTALLER TO ASSIGN AN IP ADDRESS To use Device Installer to Assign an IP address: 42. Click the Assign IP icon, press F7, or on the Device menu, select Assign IP Address. The Assign IP Address wizard appears. If a specific MES1A/B device is not selected in the Devices Tree, the first page of the wizard will ask for the Hardware (MAC) Address of the device to be configured. You will find the Hardware Address of your particular MES1A/B on a sticker attached to the device. Type the Hardware Address into the wizard and click next. 43. Since the MES1A/B is pre-configured to use DHCP (its IP address is pre-configured for which causes it to use DHCP). Therefore, do not use the Obtain an IP address automatically option in the wizard. 44. If you wish to assign a different IP address to the MES1A/B, select Assign a specific IP address and click Next. The IP Settings page of the wizard appears. 45. Type the desired IP address into the appropriate text box. 50

51 46. If required, type the Subnet Mask and Default Gateway addresses into the appropriate text boxes. 47. Click Next. The Assignment page of the wizard appears. 48. Click Assign. A Progress of task bar graph appears. When the process is Completed successfully, click Finish. 49. The new IP address appears in the Devices Tree, Device Details tab and Telnet Configuration tab. USING THE DEVICES DETAILS TAB The Device Details tab provides useful information about the MES1A/B currently selected in the Device List. Device Details Tab Although most fields in are fixed, the Name, Group and Comments fields are user configurable, allowing you to add information specific to your application. 51

52 To change any of these fields, double-click the field, then type your text into the text box that appears. UPGRADING FIRMWARE Adding Info to the Device Details Tab From time to time updated firmware versions for the MES1A/B may become available (from the B&B Electronics website). Device Installer provides a Device Upgrade Wizard which can be used to install updated firmware into the MES1A/B. To install firmware in the MES1A/B: On the Device menu, select Upgrade, or click the Upgrade icon. The Device Upgrade Wizard Step 1 of 5 dialog box appears. Device Upgrade Wizard Step If an Installation File (lxi) has already been created, select Use a specific installation file (LXI) (previously saved by user) 52

53 51. If an Installation File has not been created, select Create a custom installation by specifying individual files (Typical) and then click Next. 52. In the Device Upgrade Wizard Step 2 of 5 dialog box, browse to find the Firmware (ROM, SYS & SPB) File, then click Next. 53. In the Device Upgrade Wizard Step 3 of 5 dialog box, select No other files to install (typical), then browse and select the previously saved Setup file. 54. In the Device Upgrade Wizard Step 4 of 5 dialog box, click Next. The Device Upgrade Wizard Step 5 of 5 dialog box appears and displays a bar graph indicating progress. Succeeded appears next to a listing of each step as it is accomplished. Device Upgrade Wizard Step 5 of 5 INSTALLING PRE-SAVED CONFIGURATION FILES The same wizard can be used to install previously saved configuration settings (Setup Records) into the MES1A/B. This can be useful if you want to configure multiple MES1A/Bs with the same settings, or if you must replace an MES1A/B and want to load identical settings into the new unit. 53

54 To use the Upgrade Wizard to install configuration setting in an MES1A/B you must first save the settings in the form of a Setup Record. SAVING SETUP RECORDS To save the Setup Records for a particular device (MES1A/B) 55. Select the device in the Device List. 56. On the File menu, select Save Setup Records. The Save Setup Records dialog box appears. Save Setup Records Dialog Box 57. Select a Setup Record from the list and click Save. The Save As dialog box appears. 58. Create a filename and click Save. INSTALLING SETUP RECORDS To install a Setup Record in the MES1A/B: 59. On the Device menu, select Upgrade, or click the Upgrade icon. The Device Upgrade Wizard Step 1 of 5 dialog box appears. 54

55 Device Upgrade Wizard Step Select Create a custom installation by specifying individual files (Typical) and then click Next. 61. In the Device Upgrade Wizard Step 2 of 5 dialog box, click Next. 62. In the Device Upgrade Wizard Step 3 of 5 dialog box, select Install setup records from a file, then browse and select the previously saved Setup file. 63. In the Device Upgrade Wizard Step 4 of 5 dialog box, click Next. The Device Upgrade Wizard Step 5 of 5 dialog box appears and displays a bar graph indicating progress. Succeeded appears next to a listing of each step as it is accomplished. Device Upgrade Wizard Step 5 of 5 55

56 Configuration settings stored in the Setup file will now appear in the Telnet Configuration Menu. LOGGING SEARCH AND UPGRADE DATA Device Installer provides a logging feature that can be used to record and store information on the process of searching for devices or upgrading the MES1A/B. 64. To enable logging select Options on the Tools menu. The Options dialog box opens. Options Window, Customization Tab 65. On the Customization tab, select Activate logging during upgrading and Activate logging during searching. (Both must be selected to allow logging during search.) 66. In the Log File text box, type the path and name of the log file, or browse and create a file name in the folder of your choice. 67. Click OK to accept the changes and close the Options dialog box. 68. Click the Search icon to initiate a Search for devices on the network. 56

57 69. When the search is complete, select Log File on the View menu. Notepad opens and displays the log file. The log file contains the date and time for each entry. Log File in Notepad USING PING Device Installer provides the convenience of implementing the Ping network utility from within the Device Installer window. Ping provides the option of checking to see whether messages can be sent to and received from a device on the network at a specified IP address. It also provides information on the time required for responses from the device. To open the Ping Device window, select Ping on the Tools menu, or press F4. Type the IP address of the network device you want to ping, then press Enter or click the Ping button. Click the Clear Status button to clear the Status area. Ping Device Window 57

58 USING HELP You can access Device Installer Help files by selecting Contents on the Help menu. Device Installer Help 58

59 CHAPTER 6: MODBUS BASICS If you are reading this manual you are probably in the process of interfacing legacy Modbus ASCII/RTU devices to a network. Chances are you already have some knowledge and familiarity with Modbus ASCII/RTU but possibly somewhat less knowledge of Modbus/TCP and/or networking in general. Most likely your biggest questions relate to what is involved in bringing the two together. This section provides: a basic introduction to Modbus some information on Modbus/TCP some tips and suggestions for ensuring success MODBUS ASCII/RTU The Modbus protocol emerged in the mid-1970s as an early protocol for linking terminals with Modicon PLCs using a master/slave (sometimes called a master/client) relationship. A simple, open, message-based protocol, it caught on quickly and became a defacto standard in the industry. It supports asynchronous point-to-point and multidrop communications and can be used with a variety of serial interfaces (RS-232, RS-422, RS-485, modems, etc). The original Modbus specification included two possible transmission modes: ASCII and RTU. Modbus RTU mode is the most common implementation, using binary coding and CRC error-checking. Modbus ASCII messages, though somewhat more readable because they use ASCII characters, is less efficient and uses less effective LRC error checking. ASCII mode uses ASCII characters to begin and end messages whereas RTU uses time gaps (3.5 character times) of silence for framing. The two modes are incompatible so a device configured for ASCII mode cannot communicate with one using RTU. All Modbus communications are initiated by Modbus masters using a polling, query/response format. The master can send broadcast messages (using a slave address of 0), which all slaves accept, but do not reply to. More commonly the 59

60 master polls individual slaves sequentially. In each poll it sends a message containing a device address, followed by a function code, any data that maybe required, and an error check field. The addressed slave responds with a similar message structure. Typically it repeats back its address and the function code, and then sends a field indicating the number of bytes of data it is sending, followed by the data and the error check field. Slave addresses can range from 1 to 247. Function codes include several common ones typically used in all applications, and additional ones that may be implemented in specific cases. Common function codes include: Read Coil Status (01), Read Input Status (02), Read Holding Registers (03) and Read Input Registers (04). When a master sends a message to a slave it expects to receive a valid response within certain length of time. If the slave does not receive the message, or if the slave receives the message but an error is detected, it does not respond. If the slave cannot respond appropriately for some other reason (e.g. it does not recognize the function code), it will return a message containing an exception response. MODBUS/TCP Modbus/TCP is a much more recent development, created to allow Modbus ASCII/RTU protocol to be carried over TCP/IP-based networks. Modbus/TCP embeds Modbus messages inside TCP/IP frames. Although the implementation is fairly simple, characteristics associated with networking add some challenges. For example, because Modbus masters expect and require responses to their polls within a certain time frame, the non-deterministic (and other) aspects of TCP/IP networks have to be considered. Modbus/TCP sets up connections between nodes on the network, sending requests via TCP in a half-duplex fashion. TCP allows multiple requests to be pipelined, or queued in a buffer waiting to be serviced. Modbus/TCP has the capability to use transaction identifiers (sequence numbers), but some early manufacturers of Modbus/TCP equipment did not use them. In some cases this can create problems for Modbus/RTU devices connected to the network through interfaces. If a request from a master is lost, or contains an improper function code, the slave does not respond. The master may re-initiate the request, or there may be other requests in 60

61 the pipeline. Responses to later, or other, requests may become out of sync and the master may match the wrong response with a request. The resulting symptoms could range from appearing to receive wrong data from a slave, to slaves going off-line, to a gradually slowing down of response time. Another aspect of Modbus/TCP that must be considered relates to the Unit ID field. Modbus/RTU incorporates the slave address field but Modbus/TCP replaces the slave address field with a Unit ID field. TCP/IP uses IP addresses to find specific nodes on the network. By using the IP address to specify the node, and the Unit ID to specify a Modbus/RTU device attached to that node, multiple slaves can be located at a single IP address. Unfortunately, some manufacturers of early Modbus/TCP systems assumed only one slave per IP address and always used a Unit ID of 00. If this early equipment is used, only one Modbus/RTU slave can be connected to an MES1A/B. (The MES1B is capable of RS-485 multidrop, allowing multiple slaves.) HINTS AND TIPS A few simple suggestions that may assist you if your system is experiencing problems include: Slow down the polling rate. Try the Disable Pipeline option in the MES1A/B configuration menu. Make sure your Modbus/TCP equipment uses sequence and Unit ID numbers. 61

62 APPENDIX A: DEFAULT CONFIGURATION SETTINGS IP Address: /DHCP/BOOTP/AutoIP Gateway IP Address: Not set Netmask: Not set Telnet Configuration Password: Not set Attached Device: Slave Serial Protocol: Modbus/RTU, Slave Interface Type: MES1A RS-232 MES1B RS-422/485 Serial Parameters: 9600, 8, N, 1 CP1 Function: MES1A - Not used MES1B RS-485 Enabled CP2 Function: Not used CP3 Function: Not used Slave Address: 0 (auto maps to 1) 62

63 Allow Modbus Broadcasts: 2 (no) Use MB/TCP 00BH/00AH Exception Responses: 2 (yes) Disable Modbus/TCP pipeline: 1 (no) Character Timeout: 50 milliseconds Message Timeout: 5000 milliseconds Serial TX delay after RX: 0 milliseconds Swap 4x/0H to get 3x/1x: No 63

64 APPENDIX B: PRODUCT SPECIFICATIONS Models: MES1A, MES1B Manual: Paper copy of this manual, PDF available CD-ROM disc: XPort Device Installer software PDF of MES1A/MES1B User Manual PDF of Quick Start guide Operating Systems supported Windows 98/ME/2000/XP/NT 4.0 (call B&B Tech Support for other operating systems) Dimensions MES1A/MES1B 1.25 x 4.5 x 4.75 in (3.2 x 11.3 x 12.2 cm) Power Supply Requirements: 10 VDC to 30VDC (3.6 Watts) Power Supply: Not included Power Connector: Removable screw terminal (2) block with screw down Power Consumption: 3.6 Watts 300 ma) 64

65 Operating Temperature: -20 to 80 C (-4 to 176 F) Storage Temperature: 40 to 85 C ( 40 to 185 F) Humidity: 10% to 90% R.H. non-condensing Approvals: CE, FCC Class B Link Integrity Indicator: Green/Orange LED (on Ethernet connector) Activity Indicator: Green/Orange LED (on Ethernet connector) Power Indicator: Red LED Reset Switch Recessed momentary switch, press for 1 second to reboot (hardware reset) Ethernet Connector: Single RJ-45 female (with built-in LED indicators) Ethernet Standards Supported: IEEE /100 Mbps auto-detecting, 10BaseT, 100BaseTX Protocols Supported: TCP, UDP, DHCP, SNMP, TELNET, ICMP, ARP, TFTP, Modbus ASCII, Modbus RTU, Modbus/TCP 65

66 Serial Protection: 12V TVS for MES1A 5 V TVS for MES1B Serial Connector: MES1A - 9 pin D-type male (DB-9M) MES1B removable screw terminal (5) block with screw down Interface Lines Supported: MES1A RS-232 TD, RD, GND MES1B RS-422/485 TDA(-), TDB(+), RDA(-), RDB(+), GND Serial Data Rates: 300, 600, 1200, 2400, 3600, 4800, 9600, 19200, 38400, 57600, bps Parity: None, Even, Odd Data Bits: 7 or 8 Stop Bits: 1, 2 Flow control: None 66

67 Configuration Modes: Telnet, XPort Device Installer with integrated Telnet Device Management: SNMP RFC 1213/1215/1316/131 IP Address Assignment: Static IP or DHCP (IP is set to ) Accessories: DIN/Panel mount bracket 67

68 APPENDIX C: DIMENSIONAL DIAGRAMS Dimensional Diagram of the MES1A 68

69 Dimensional Diagram of the MES1B 69

70 APPENDIX D: SERIAL CONNECTIONS DB-9M Signal RS-232 DTE Pin 2 Receive Data RXD In 3 Transmit Data TXD Out 5 Signal Ground GND --- RS-232 Connections for DB-9 Connector 70

International Headquarters. European Headquarters

International Headquarters. European Headquarters VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_0613 Revision: 2.0 -- February 2013 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International

More information

International Headquarters. European Headquarters

International Headquarters. European Headquarters VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_1116 Revision: March 2016 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International Headquarters

More information

MESP211 Series USER MANUAL

MESP211 Series USER MANUAL MESP211 Series USER MANUAL 1 Advantech B+B SmartWorx - Americas 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 Fax (815) 433-5105 Advantech B+B SmartWorx - European Headquarters Westlink Commercial

More information

International Headquarters

International Headquarters IE-MediaChassis/1 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com support@bb-elec.com

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

Manual Documentation Number: ES1A-2907m pn6909-rev003 B&B Electronics Mfg Co Inc 707 Dayton Rd - PO Box Ottawa IL Ph

Manual Documentation Number: ES1A-2907m pn6909-rev003 B&B Electronics Mfg Co Inc 707 Dayton Rd - PO Box Ottawa IL Ph Model: ES1A Mini Ethernet to RS-232 Converter Manual Documentation Number: ES1A-2907m pn6909-rev003 Manual Documentation Number: ES1A-2907m pn6909-rev003 International Headquarters B&B Electronics Mfg.

More information

TEX-ICC400 Ethernet. Ethernet. TEX-ICC400 Ethernet. Configuration of TEX-ICC400 Serial Options -1- ASCII. Modbus/TCP ASCII.

TEX-ICC400 Ethernet. Ethernet. TEX-ICC400 Ethernet. Configuration of TEX-ICC400 Serial Options -1- ASCII. Modbus/TCP ASCII. TEX-ICC400 Ethernet TEX-ICC400 Ethernet The TEX-ICC400 series controllers are available with two Ethernet options for Com port 1. They can be supplied with an ASCII Ethernet interface or with a Modbus/TCP

More information

International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL USA

International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL USA RS-232/422/485 / Current Loop Six-Port Multi-Interface Ethernet Serial Server Model: ESP906CL ESP906CL Manual Title Page International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa,

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Manual Documentation Number: ESR90x-5012m B&B Electronics Mfg Co Inc 707 Dayton Rd - Ottawa IL Ph Fax

Manual Documentation Number: ESR90x-5012m B&B Electronics Mfg Co Inc 707 Dayton Rd - Ottawa IL Ph Fax RS-232/422/485 Multi-Interface Industrial Ethernet Serial Servers Models: ESR901, ESR902, ESR904 Manual Documentation Number: ESR90x-5012m International Headquarters B&B Electronics Mfg. Co. Inc. 707

More information

1 MESR321-xx_R001_2113m

1 MESR321-xx_R001_2113m Vlinx MESR321 Isolated Industrial Modbus Gateway 1 Vlinx MESR321 Models MESR321 Documentation Number: This product was designed and manufactured in Ottawa, Illinois, USA, Using domestic and imported parts

More information

Manual Documentation Number: ESP _0508m B&B Electronics Mfg Co Inc 707 Dayton Rd - PO Box Ottawa IL Ph Fax

Manual Documentation Number: ESP _0508m B&B Electronics Mfg Co Inc 707 Dayton Rd - PO Box Ottawa IL Ph Fax RS-232 / RS-422 / RS-485 Multi-Interface Ethernet Serial Servers Models: ESP901, ESP901E, ESP902, ESP902E Manual Documentation Number: ESP901-902_0508m International Headquarters B&B Electronics Mfg. Co.

More information

EtherSeries Modbus Gateway EMB-2 User s Guide

EtherSeries Modbus Gateway EMB-2 User s Guide EtherSeries Modbus Gateway EMB-2 User s Guide Revised March 25, 2004 Firmware Version 1.4 FCC Statement This device complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

User s Manual USB Server UE204

User s Manual USB Server UE204 User s Manual USB Server UE204 UE204 Document Number: UE204_2711m International Headquarters: 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 Website: www.bb-elec.com Sales e-mail: orders@bb-elec.com

More information

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA PMEUCM Hardware Manual PMEUCM Hardware Installation Manual This manual covers the PMEUCM hardware features and installation procedures. Effective: August 10, 2017 Niobrara Research & Development Corporation

More information

Ethernet Serial Server

Ethernet Serial Server Ethernet Serial Server Users Manual Eport-101, Eport-102, Eport-104, Eport108 1 INTRODUCTION... 1 1.1 FEATURES... 1 1.2 PRODUCT SPECIFICATIONS... 2 1.3 DEFAULT SETTINGS... 3 2 COMMUNICATION MODES... 4

More information

Redirector User Guide

Redirector User Guide Redirector User Guide Revision B November 04, 2005 Part Number GC-800-235 Copyright and Trademark Copyright 2004, Grid Connect, Inc. All rights reserved. No part of this manual may be reproduced or transmitted

More information

tsh-700 Series User Manual

tsh-700 Series User Manual tsh-700 Series User Manual Tiny Serial Port Sharer Aug. 2017 Ver. 1.6 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery

More information

Serial to Ethernet Modbus Adapter User Guide February 5, 2007 Part Number MW-MBETH

Serial to Ethernet Modbus Adapter User Guide February 5, 2007 Part Number MW-MBETH Serial to Ethernet Modbus Adapter User Guide February 5, 2007 Part Number MW-MBETH Copyright and Trademark Copyright 2007, Methodworks, LLC. All rights reserved. No part of this manual may be reproduced

More information

Modbus Protocol User Guide

Modbus Protocol User Guide Modbus Protocol User Guide Part Number 900-271 Revision H April 2013 Copyright and Trademark Contacts 2013 Lantronix, Inc. All rights reserved. No part of the contents of this book may be transmitted or

More information

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols USER MANUAL Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols Contents at a Glance: Section 1 General Information RM-PS-024-01F 3 Section

More information

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA DUCM Hardware Manual DUCM Hardware Installation Manual This manual covers the DUCM hardware features and installation procedures. Effective: May 29, 2015 Niobrara Research & Development Corporation P.O.

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

BFR3000 Modbus Router

BFR3000 Modbus Router BFR3000 Modbus Router Product User Guide Software Build Date: December 17 th 2015 Version 3 Platform: N34 Real Time Automation, Inc. 1 1-800-249-1612 Trademarks All other trademarks and registered trademarks

More information

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH485Ex1 Doc No: PH485Ex1-UM-001 #1 RS-485 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

ESERV-M12T Modbus Gateway User Manual

ESERV-M12T Modbus Gateway User Manual ESERV-M12T Modbus Gateway User Manual Table of Contents TABLE OF CONTENTS INTRODUCTION... 1 About s... 1 Modbus Gateway Manager Configuration Software... 2 ESERV-M12-T MODBUS GATEWAY HARDWARE... 3 Package

More information

Lantronix UDS-10 (CoBox) w/sielox Firmware B03.54 or greater Set-up, Installation, and FAQ Notes

Lantronix UDS-10 (CoBox) w/sielox Firmware B03.54 or greater Set-up, Installation, and FAQ Notes Lantronix UDS-10 () w/sielox Firmware B03.54 or greater Set-up, Installation, and FAQ Notes June 2005 (Updated March 2006) Copyright 2006 by Sielox, LLC. Published by: Sielox 170 East Ninth Avenue Runnemede,

More information

Modbus Protocol User Guide

Modbus Protocol User Guide Modbus Protocol User Guide Part Number 900-271 Revision L November 2016 Intellectual Property 2016 Lantronix, Inc. All rights reserved. No part of the contents of this publication may be transmitted or

More information

NetBiter Serial Server User Manual

NetBiter Serial Server User Manual User Manual IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 17 29 09 email info@intellicom.se web www.intellicom.se Revision List Revision Date Author

More information

Canlan INSTALLATION MANUAL

Canlan INSTALLATION MANUAL Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

Installation and User Guide

Installation and User Guide Installation and User Guide Trademarks and Notices Notice Comtrol Corporation. SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF THIS PRODUCT FOR A PARTICULAR PURPOSE. Comtrol

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

SE200 Series Switches. User Manual

SE200 Series Switches. User Manual SE200 Series Switches User Manual Advantech B+B SmartWorx Americas 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 Fax (815) 433-5105 Advantech B+B SmartWorx European Headquarters Westlink Commercial

More information

International Headquarters. European Headquarters

International Headquarters. European Headquarters Giga-McBasic-II Media Converter 1 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com

More information

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds MESR424 4-Port Industrial Modbus Gateway MESR424_r000_2913ds Ethernet-Enable Modbus RS-232/422/485 MODBUS TCP, ASCII & RTU Modbus Flexibility Serial & Ethernet, Masters & Slaves Modbus Messaging Priority

More information

1 Port RS232 Serial over IP Ethernet Device Server

1 Port RS232 Serial over IP Ethernet Device Server 1 Port RS232 Serial over IP Ethernet Device Server NETRS2321P *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario

More information

XPort Development Kit Quick Start Guide. XPort Quick Start Guide

XPort Development Kit Quick Start Guide. XPort Quick Start Guide XPort Development Kit Quick Start Guide XPort Quick Start Guide Part Number 900-312 Revision D January 2006 Contents Contents... 1 Introduction... 1 What s in the Box... 1 Connect the XPort Evaluation

More information

EQ-DCM User Manual Revision 1.02 Sep 10, 2013

EQ-DCM User Manual  Revision 1.02 Sep 10, 2013 EQ-DCM User Manual www.equustek.com Revision 1.02 Sep 10, 2013 Contents INTRODUCTION...5 ABOUT THIS MANUAL... 5 INTENDED AUDIENCE... 5 HARDWARE SPECIFICATIONS...6 PHYSICAL SPECIFICATIONS... 6 HARDWARE

More information

Quick Start Guide Elinx ESW500 Series. Managed Din Rail Ethernet Switch

Quick Start Guide Elinx ESW500 Series. Managed Din Rail Ethernet Switch Quick Start Guide Elinx ESW500 Series Managed Din Rail Ethernet Switch ESW500 Series Documentation Number: ESW500series-1012qsg International Headquarters: 707 Dayton Road Ottawa, IL 61350 USA Phone (815)

More information

Overview. Table of contents

Overview. Table of contents 1 Table of contents Overview... 1 Applications... 2 Connecting and adjusting of converter... 3 Communication parameters adjusting... 5 RealPort - virtual serial port... 12 Installing virtual serial port

More information

11Mbps Wireless LAN Smart Station Adapter

11Mbps Wireless LAN Smart Station Adapter 11Mbps Wireless LAN Smart Station Adapter Quick Start Guide Version 1.6 The next-generation wireless LAN device 11Mbps Wireless LAN Smart Station adapter, brings Ethernet-like performance to the wireless

More information

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan Print Server User s Manual Rev. 01 (April, 2004) Made In Taiwan TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 5 PACKAGE CONTENTS... 6 SYSTEM REQUIREMENTS... 6 GENERAL FEATURES... 7 PRODUCT VIEW...

More information

BACnet Router Start-up Guide

BACnet Router Start-up Guide BACnet Router Start-up Guide BAS Router (BACnet Multi-Network Router) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after January 2015 Kernel Version: Application Version: Document

More information

FieldServer X-25 Start-Up Guide

FieldServer X-25 Start-Up Guide Sierra Monitor Company FieldServer X-25 Start-Up Guide APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after April 2013 Kernel Version: 6.10 Document Revision: 0 FieldServer FS-X25 Start-Up

More information

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide VxI Power Ltd. IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide 01/12/2015 Document Number: 14970-020A Issue Number: 2 Contents 1.0 Device Overview... 2 2.0 Getting Started... 3 2.1 Connecting the Device...

More information

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m This product designed and manufactured in Ottawa, Illinois USA of domestic and imported parts by

More information

MGate MB3000 Modbus Gateway User Manual

MGate MB3000 Modbus Gateway User Manual MGate MB3000 Modbus Gateway User Manual Sixth Edition, July 2012 www.moxa.com/product 2012 Moxa Inc. All rights reserved. MGate MB3000 Modbus Gateway User s Manual The software described in this manual

More information

TRP-C37M User s Manual

TRP-C37M User s Manual TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed OCT. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

NETRS232 Series Quick Installation & Advanced Features Guide

NETRS232 Series Quick Installation & Advanced Features Guide NETRS232 Series Quick Installation & Advanced Features Guide Rev. B05 1 Getting Started Congratulations on your purchase of a StarTech NETRS232. NETRS232s connect serial devices to Ethernet networks. Any

More information

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION

MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION ICP PANEL-TEC MICROBRIDGE INSTALLATION AND OPERATION GUIDE MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION Revision History Revision Date Author Comments 000 02 June 2009 David Walker Initial release.

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

multisys User manual Technical parameters D2-MSMT-1 Gateway from Modbus TCP to Modbus RTU, serial RS _EDEBDA _EN

multisys User manual Technical parameters D2-MSMT-1 Gateway from Modbus TCP to Modbus RTU, serial RS _EDEBDA _EN User manual Technical parameters multisys D2-MSMT-1 Gateway from Modbus TCP to Modbus RTU, serial RS485 System I English Your partner for network analysis KBR Kompensationsanlagenbau GmbH does not accept

More information

Ethernet Interface Module

Ethernet Interface Module Interface Manual 1 Ethernet Interface Module SignalFire Number: ENET-DIN The SignalFire Ethernet Gateway has the following features: - Wide range DC power input. 6 to 36VDC - Power Over Ethernet (POE)

More information

EGW1-IA3-MB User s Manual

EGW1-IA3-MB User s Manual www.exemys.com Rev. 0 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information

More information

User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP) User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP) FDC_PC-E_Manual_V1.0_August-2007 1 of 19 COPYRIGHT NOTICE This manua l is a publication of Future Design

More information

User Manual Anybus Modbus TCP/RTU Gateway

User Manual Anybus Modbus TCP/RTU Gateway User Manual AB7702 Rev. 2.01 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad, Sweden E-mail: info@hms-networks.com

More information

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual First Edition, June 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. MGate EIP3000

More information

USB Server User Manual

USB Server User Manual 1 Copyright Notice Copyright Incorporated 2009. All rights reserved. Disclaimer Incorporated shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential

More information

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED

More information

MODBUS TCP/IP TO MODBUS SERIAL GATEWAY. MODEL No: MGate-1024-DC VER 2.0

MODBUS TCP/IP TO MODBUS SERIAL GATEWAY. MODEL No: MGate-1024-DC VER 2.0 MODBUS TCP/IP TO MODBUS SERIAL GATEWAY MODEL No: MGate-1024-DC VER 2.0 MILLENNIUM TECHNOLOGIES 440, MASTER MIND 1, ROYAL PALMS ESTATE AAREY MILK COLONY, GOREGAON (EAST), MUMBAI-400065. INDIA. PH: - 91-22-65229736,

More information

XPort Direct+ Demonstration Kit Quick Start Guide

XPort Direct+ Demonstration Kit Quick Start Guide XPort Direct+ Demonstration Kit Quick Start Guide Part Number 900-525 Revision A October 2007 Contents Contents... 1 Introduction... 1 What s in the Box... 1 LEDs... 1 Connect the XPort Direct+ Demonstration

More information

ABOUT THIS GUIDE... 4

ABOUT THIS GUIDE... 4 TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 6 PACKAGE CONTENTS... 7 SYSTEM REQUIREMENTS... 7 GENERAL FEATURES... 8 PRODUCT VIEW... 9 HARDWARE INSTALLATION... 11 NETWORKING APPLICATION... 11

More information

XPress DR Industrial Device Server User Guide

XPress DR Industrial Device Server User Guide XPress DR Industrial Device Server User Guide Part Number 900-772-R Revision C December 2017 Intellectual Property Warranty Contacts 2017 Lantronix, Inc. All rights reserved. No part of the contents of

More information

ExpressCard Serial Adapters User s Manual SSPXP-100 DSPXP-100 QSPXP-100 SSPXP-200/300 DSPXP-200/300 QSPXP-200/300

ExpressCard Serial Adapters User s Manual SSPXP-100 DSPXP-100 QSPXP-100 SSPXP-200/300 DSPXP-200/300 QSPXP-200/300 ExpressCard Serial Adapters User s Manual SSPXP-100 DSPXP-100 QSPXP-100 SSPXP-200/300 DSPXP-200/300 QSPXP-200/300 SSPXP/DSPXP/QSPXP-100/200/300 User s Manual P/N: 940-5000-100G Rev. 1.00 July 2007 International

More information

Operation Manual of EX9132CST-Series

Operation Manual of EX9132CST-Series Operation of EX9132CST-Series Serial to TCP/IP Converter (EX9132CST-2/ EX9132CST-RS485/ EX9132C-RS232) Version 1.0.0. 30.03.2017 Table of Contents 1 Introduction... 4 2 Overview... 5 2. 1 Package Checklist...

More information

TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0

TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0 TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0 MILLENNIUM TECHNOLOGIES 440, MASTER MIND 1, ROYAL PALMS ESTATE AAREY MILK COLONY, GOREGAON (EAST), MUMBAI-400065. INDIA. PH: - 91-22-65229736,

More information

Giga-MiniMc with LFPT. Operation Manual

Giga-MiniMc with LFPT. Operation Manual Giga-MiniMc with LFPT Operation Manual FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Part 15

More information

DGH A3000 Configuration Guide For use with DGH Modules

DGH A3000 Configuration Guide For use with DGH Modules DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation

More information

MGate MB3000 Modbus Gateway User s Manual

MGate MB3000 Modbus Gateway User s Manual User s Manual Seventh Edition, May 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

RC-SV Configuration Guide (Rev 4)

RC-SV Configuration Guide (Rev 4) Kramer Electronics, Ltd. RC-SV Configuration Guide (Rev 4) Software Version 2.1.2.69 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version, go

More information

TRP-C37M User s Manual

TRP-C37M User s Manual TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed May. 2011 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

factory field upgrade

factory field upgrade CK721-A Network Controller factory field upgrade version 3.1 build 25 24-10025-75 Revision B October, 2013 Copyright 2013 Johnson Controls, Inc. All Rights Reserved No part of this document may be reproduced

More information

Secure Com Port Redirector User Guide

Secure Com Port Redirector User Guide Secure Com Port Redirector User Guide Part Number 900-324 Revision B December 2004 Copyright and Trademark 2004, Lantronix. All rights reserved. No part of the contents of this book may be transmitted

More information

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3 TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed Apr.2014 Rev 1.3 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax:

More information

RS-232/422/485 Over IP Adapter

RS-232/422/485 Over IP Adapter RS-232/422/485 Over IP Adapter 1 port RS-232/422/485 Over IP Adapter NETRS2321E Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits

More information

Instruction Guide. 2 Channel Ultra ATA/100 PCI Card PCI2IDE100. The Professionals Source For Hard-to-Find Computer Parts. Revised: December 5, 2002

Instruction Guide. 2 Channel Ultra ATA/100 PCI Card PCI2IDE100. The Professionals Source For Hard-to-Find Computer Parts. Revised: December 5, 2002 IDE CARD 2 Channel Ultra ATA/100 PCI Card PCI2IDE100 Instruction Guide * Actual product may vary from photo Revised: December 5, 2002 The Professionals Source For Hard-to-Find Computer Parts 7 FCC COMPLIANCE

More information

RC-SV Configuration Guide Revision 3

RC-SV Configuration Guide Revision 3 Kramer Electronics, Ltd. RC-SV Configuration Guide Revision 3 Software Version 2.1.2.32 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version,

More information

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6 TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed September 1 2015 Rev 1.6 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

MESR9xx. Vlinx Industrial MODBUS Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

MESR9xx. Vlinx Industrial MODBUS Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION MESR9xx MESR9xx-1610ds-1/5 Vlinx Industrial MODBUS Ethernet to Serial Gateway Ethernet Enable MODBUS RS-232/422/485 MODBUS TCP, ASCII & RTU Modbus Flexibility Serial & Ethernet, Masters & Slaves Modbus

More information

Copyright Exemys, 2006 All Rights Reserved. Rev. 4

Copyright Exemys, 2006 All Rights Reserved. Rev. 4 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information can be found at www.exemys.com

More information

Operation Manual EX-9133C-2-MTCP

Operation Manual EX-9133C-2-MTCP Operation Manual EX-9133C-2-MTCP Modbus TCP to Modbus RTU/ASCII Converter Version 1.0.1 20th Oct. 2016 Page 0 Table of Contents 1. Introduction 3 Overview 4 Package Checklist 4 Block Diagram 5 Features

More information

Modbus TCP/RTU Gateway

Modbus TCP/RTU Gateway Modbus TCP/RTU Gateway Hardware Installation Guide for models IE-GW-MB-2TX-1RS232/485 IE-GWT-MB-2TX-1RS232/485 Second Edition, June 2014 1516600000/01/06.14 Important note: The detailed user manual, additional

More information

RG2-1TX Serial to Ethernet Interface. English Version 1.3 User Guide March 2003

RG2-1TX Serial to Ethernet Interface. English Version 1.3 User Guide March 2003 RG2-1TX Serial to Ethernet Interface English Version 1.3 User Guide March 2003 Data, Illustrations, Alterations The data and illustrations found in this document are not binding. We reserve the right to

More information

2-Port RS-232/422/485 Serial over IP Ethernet Device Server Installation Guide

2-Port RS-232/422/485 Serial over IP Ethernet Device Server Installation Guide 2-Port RS-232/422/485 Serial over IP Ethernet Device Server Installation Guide Introduction The 2-Port RS-232/422/485 Serial over IP Ethernet Device Server is designed to operate serial ports over 10/100

More information

BACnet Router Start-up Guide

BACnet Router Start-up Guide BACnet Router Start-up Guide BAS Router (BACnet Multi-Network Router) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after October 2014 Kernel Version: 6.15 Document Revision: 3 QuickServer

More information

Hubbell Building Automation #LXBASM. ProtoNode LER Startup Guide

Hubbell Building Automation #LXBASM. ProtoNode LER Startup Guide Hubbell Building Automation #LXBASM ProtoNode LER Startup Guide For Interfacing Customer Product: Hubbell Automation LX Lighting Control Panels To Building Automation Systems: BACnet MS/TP, BACnet/IP,

More information

EQ7000. User Manual. Rev 1.00

EQ7000. User Manual. Rev 1.00 EQ7000 User Manual Rev 1.00 www.equustek.com Revision 1.00 February 27, 2009 Contents INTRODUCTION...4 ABOUT THIS MANUAL...4 INTENDED AUDIENCE...4 HARDWARE SPECIFICATIONS...5 PHYSICAL SPECIFICATIONS...5

More information

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual HOME AUTOMATION, INC. Model 93A00-1 Serial Server User s Manual Document Number 93I00-1 Rev. A December, 2009 Introduction The 93A00-1 is a RS232/RS485 to TCP/IP converter integrated with a robust system

More information

1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2

1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2 - i - Table of Contents 1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2 2. Installation... 3 Windows 7/ Vista... 3 Windows XP... 5 Windows 2000... 7 Windows

More information

XPress DR+W Quick Start Guide

XPress DR+W Quick Start Guide Industrial Device Server Quick Start Guide 2006 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-446 Rev. A 10/06 XPRESS DR+W QUICK START CONTENTS What s In the Box..........................................................2

More information

Any device, including routers and hosts, is running an implementation of IP address Host

Any device, including routers and hosts, is running an implementation of IP address Host INSTRUCTION MANUAL IM471-U v0.1 EMI-10L Introduction EMI-10L converter lets you convert a serial RS485 communications port on a bus Ethernet with TCP / IP. The concepts and terms commonly used in the TCP

More information

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control Installation Manual SM-RS232 16-Port RS232 Router with optional TCP/IP control Control up to 16 RS232 compliant devices up to 50 feet away over UTP or from anywhere via TCP/IP (optional) What s in the

More information

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch Quick Start Guide Elinx ESW100 Series 5 and 8 port Unmanaged Ethernet Switch ESW100 Series Documentation Number: ESW100series-1112qsg International Headquarters: 707 Dayton Road Ottawa, IL 61350 USA Phone

More information

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display VP Process Inc. Model: Modbus RTU LCD Display User Manual Ver: 2.0 Aug. 2017 P a g e 1 Standard Features Low Power (12-24 VDC) 2.1 x 5mm Barrel Plug, RJ45 and Terminal Block Input On-Board Local Temperature

More information

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch Quick Start Guide Elinx ESW200 Series 5 and 8 port Unmanaged Ethernet Switch ESW200 Series Documentation Number: ESW200series-1112qsg International Headquarters: 707 Dayton Road Ottawa, IL 61350 USA Phone

More information

ABLELink. Modbus Gateway MB5000 Series User s Manual

ABLELink. Modbus Gateway MB5000 Series User s Manual ABLELink MB5000 Series User s Manual Version 1.1 Updated in March, 2010 TEL: 886-3-5508137 FAX: 886-3-5508131 http://www.atop.com.tw Table of Contents Table of Contents... 2 Introduction... 4 Features...

More information