2 Table of Contents 1.0 INTRODUCTION PRODUCT DESCRIPTION FEATURES SPECIFICATIONS APPLICATION AREAS CONNECTION DETAILS LED INDICATIONS CONNECTION DETAILS SOFTWARE INSTALLATION HARDWARE INSTALLATION HARDWARE MOUNTING AND CABLING DEVICE CONFIGURATION CONFIGURATION PARAMETERS...12 SerEth-1P.doc, Ver2.0 2
3 1.0 INTRODUCTION PRODUCT DESCRIPTION This board is a Serial-to-Ethernet converter board. This board is very useful for connecting a legacy serial device to an Ethernet network. There are three types of isolated serial outputs available (i.e. RS-232, RS-485, RS-422). It supports virtual mode of operation. In virtual mode, one can configure the board as a PC COM port, which enables to run legacy application software based on standard PC COM port. We also provide various Data Acquisition Cards with serial interfaces such as Digital I/O Cards, Relay Driver Cards, and Analog I/O Cards etc FEATURES 10/100Mbps Ethernet port Asynchronous Serial Ports Isolated RS-232/RS-422/RS-485 Serial port RJ-45 Socket for Ethernet Screw terminals for RS-232, RS-422 and for RS-485 DIN rail mountable and/or box packed Device Configuration utility Automatic detection of device 24Volts operation SPECIFICATIONS Baud Rate Supported 1200,2400,4800,9600,19200,38400,57600, Core Module Memory 64KB Flash, 4KB RAM Ethernet 10/100Mbps Dimension 130x75x35 mm Power Consumption 50mA@24V, 2Watt max APPLICATION AREAS Industrial Automation, Building Automation, Office Automation, Point of Sale, Medical etc. SerEth-1P.doc, Ver2.0 3
4 1.0.5 CONNECTION DETAILS Signal Name LAN Signal description For connecting Ethernet cable 10-30V V DC GND Ground of power supply TXA-232 RXA-232 GND TXA+/ D+ TXA-/ D- RXA(+) RXA(-) RS-232 Transmitter line RS-232 Receiver line Isolated ground for RS232 RS-422 Transmitter Positive line / RS485 Data+ Line RS-422 Transmitter Negative line / RS485 Data- Line RS-422 Receiver Positive line RS-422 Receiver Negative line LED INDICATIONS Signal Name Signal description ACT Indicates data activities on LAN LINK Indicates Ethernet LINK TX POWER RX Indicates Data transmission from Converter Indicates unit is powered ON. Indicates data received by converter SerEth-1P.doc, Ver2.0 4
5 1.0.7 CONNECTION DETAILS On the rare side, you will find a 4 WAY DIP SWITCH inside. Please make switch settings as described below to select appropriate hardware interface. PROTOCOL SW1 SW2 SW3 SW4 RS232 ON OFF OFF OFF RS485 2 Wire OFF ON OFF ON RS422 OFF OFF ON OFF RS485 4 Wire OFF OFF ON ON SerEth-1P.doc, Ver2.0 5
6 2.0 SOFTWARE INSTALLATION Unpacking the product you will find Software installation CD. Please browse SinglePortSetupUtility_V2.0.0 folder and run Setup.exe, which will install the necessary software and files in to your computer. The installation steps are as follows: Setup will initialize installation Then you will next screen as shown below. Click Next to continue to the next window. SerEth-1P.doc, Ver2.0 6
7 The software will install to default directory. The default Directory is C:\Program Files\Millennium Technologies\MT_1P_SERETH_CONFIG_V2.0.0\MT_1P_SERETH_CONFIG_V2.exe. If you want to change location please browse the desired folder. SerEth-1P.doc, Ver2.0 7
8 Please click on Next button The installation process will begin. You can see progress on the screen. After finishing the process you will se following screen. Click on Finish button. SerEth-1P.doc, Ver2.0 8
9 3.0 HARDWARE INSTALLATION HARDWARE MOUNTING AND CABLING Apply +24V DC power supply to converter. Connect a cross cable between the converter and your PC if it peer-to-peer connection or else straight cable if connected to HUB or Switch in a local network. Connect any serial device, which you want to interface to the converter. Power-on the device now. 4.0 DEVICE CONFIGURATION The user will have to configure the device using the configuration Utility. This utility is provided to search, install and configure the device in a network. All settings like baud rate, IP address, subnetmask, gateway etc. can be set using this utility. These settings are stored in permanent flash memory of the converter. To run the utility, click on desktop icon or browse installation folder and run MT_1P_SERETH_CONFIG_V2.0.0.exe.. First you will see welcome screen. Then you will see following screen SerEth-1P.doc, Ver2.0 9
10 Please click on Search Broadcast Search menu. The utility will start searching device(s). You can see detected devices in table. After search is finished you can see all the devices found in the table. Please double click on the device you want to configure. The configure screen will appear. SerEth-1P.doc, Ver2.0 10
11 Please set various parameters displayed on screen. The description of each parameter is given in next section. To apply changes click on Apply button. The device selection screen will appear again. Please search the device again and verify all changes are applied correctly. If converter and computer are in two different networks, you can configure device using Search by IP method. Please click on Search Search By IP menu. You will be asked IP of converter as shown below. Please enter IP address of converter and click on OK. The remaining steps to search and configure converter are similar. SerEth-1P.doc, Ver2.0 11
12 5.0 CONFIGURATION PARAMETERS Network Settings: 1. Host IPADDRESS: This IP address is the IP address of the PC where the configuration utility is installed. 2. DIN: Device Identification No.(No need for users). Default: 2 3. IP ADDRESS: Put the IP address for the device u want to set. Default SUBNET: put subnet mask for the device according to your network settings. Default: GATEWAY: put Gateway for the device according to your network settings. Gateway is required only when the device is in other network Default: Note: Please use GATEWAY settings, only if converter and computer are placed in different networks. Otherwise, keep it to default i.e In case converter and computers are in different networks, please set local IP of router, connecting two networks, as Gateway to converter. Serial Settings: 1. BAUD RATE: Baud rate for the serial device. You can configure from 1200 to Default: Parity: Parity you can select from NO Parity, Even Parity, and Odd parity according to the serial device supports. Default: No Parity 3. Interface: Interface can be RS-232, RS-485 and RS-422. Default: RS Socket Alive Time: If there is no any activity on Ethernet for the amount of time (in mins) specified in parameter, then device closes its socket after time is over. Default : 0 mins.(socket is never closed) 5. Mode: Please select Virtual Mode to use converter as virtual COM port. The virtual comport utility VSPM is provided in CD. Please browse VSPM folder and read user manual to install and configure VSPM. 6. Packetization Timeout: This is the maximum time, in milliseconds, between 2 bytes, being received on serial port, after which complete packet will be sent on Ethernet. This feature is very useful in time critical protocol, like MODBUS RTU. The converter will wait for complete packet to receive and transfers the complete packet to Ethernet. Range is 0 to 255ms. If Packetization Timeout is set to 0ms, this feature is disabled, i.e. converter does not wait for complete packet to receive (no data for specified time condition) and sends data on Ethernet as it comes on serial port. SerEth-1P.doc, Ver2.0 12
MODBUS TCP/IP TO MODBUS SERIAL GATEWAY. MODEL No: MGate-1024-DC VER 2.0
MODBUS TCP/IP TO MODBUS SERIAL GATEWAY MODEL No: MGate-1024-DC VER 2.0 MILLENNIUM TECHNOLOGIES 440, MASTER MIND 1, ROYAL PALMS ESTATE AAREY MILK COLONY, GOREGAON (EAST), MUMBAI-400065. INDIA. PH: - 91-22-65229736,
More informationTTL TO ETHERNET Module. MODEL No: TTL-Sereth1P VER 1.0
TTL TO ETHERNET Module MODEL No: TTL-Sereth1P VER 1.0 MILLENNIUM TECHNOLOGIES 440, MASTER MIND 1, ROYAL PALMS ESTATE AAREY MILK COLONY, GOREGAON (EAST), MUMBAI-400065. INDIA. PH: - 91-22-65229736, 91-22-28794703
More informationUser Manual A08. User Manual
A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...
More informationIndustrial Serial Device Server
1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device
More informationMotortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision
Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803
More informationUser Manual Edition: v a
WPC-832-Con 2 Ports Modbus TCP to Modbus RTU Wi-Fi, Ethernet connection Data Concentrator User Manual Edition: v.201809a http://www.tcpipweb.com Table of Contents Introduction------------------------------------------------------------------------------------------------------------------------------
More informationUSER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH485Ex1 Doc No: PH485Ex1-UM-001 #1 RS-485 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationLantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual
Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED
More informationUSER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationEQ-DCM User Manual Revision 1.02 Sep 10, 2013
EQ-DCM User Manual www.equustek.com Revision 1.02 Sep 10, 2013 Contents INTRODUCTION...5 ABOUT THIS MANUAL... 5 INTENDED AUDIENCE... 5 HARDWARE SPECIFICATIONS...6 PHYSICAL SPECIFICATIONS... 6 HARDWARE
More informationMB40 & MB45 MODBUS TCP/IP Gateway Handbook
MB40 & MB45 MODBUS TCP/IP Gateway Handbook Version 1.2 29 July 2014 Environdata Australia Pty Ltd 42-44 Percy Street Warwick Queensland 4370 Australia Phone: (07) 4661 4699 Fax: (07) 4661 2485 International
More informationAny device, including routers and hosts, is running an implementation of IP address Host
INSTRUCTION MANUAL IM471-U v0.1 EMI-10L Introduction EMI-10L converter lets you convert a serial RS485 communications port on a bus Ethernet with TCP / IP. The concepts and terms commonly used in the TCP
More informationUser s Guide. Ethernet Module for Barcode Printer
User s Guide Ethernet Module for Barcode Printer 1. ETHERNET MODULE... 2 1-1. Functions... 2 1-2. General Specifications... 2 2. ETHERNET MODULE INSTALLATION... 3 2-1. Ethernet Module Installation for
More informationTel: Fax:
NP302 Series 2-port RS-232 232/485/422 to Ethernet Serial Server User manual Shenzhen 3onedata Technology Co.,Ltd Tel: +86-755-26702688 Fax: +86-755-26703485 www.3onedata.com Contents 1. Introduction...
More informationIntesisBox Modbus Server Fidelio IP
IntesisBox Modbus Server Fidelio IP User Manual r1 eng Issue Date: 10/04/2014 Intesis Software S.L. All Rights Reserved. Information in this document is subject to change without notice. The software described
More informationINDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter
Document Name : User Manual for SC10EJ Serial to Ethernet Converter Page 1 of 10 INDEX 1. Technical Specifications 1 2. Modes of Operation 1 3. Configuring the SC10 EJ : Through Serial Port 2 a. Configuring
More informationTRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6
TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed September 1 2015 Rev 1.6 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More informationMGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual
MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual First Edition, June 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. MGate EIP3000
More informationTRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4
TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More informationACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter
APCON100 series Operation Manual RS-232 to Ethernet Converter Page 1 of 24 APCON100 series Operation Manual Index Chapter 1 Specifications 2 Chapter 2 Introduction 3 Chapter 3 Easy Installation 4 Chapter
More informationIntech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to
More informationNetBiter Serial Server User Manual
User Manual IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 17 29 09 email info@intellicom.se web www.intellicom.se Revision List Revision Date Author
More informationMGate MB3000 Modbus Gateway User Manual
MGate MB3000 Modbus Gateway User Manual Sixth Edition, July 2012 www.moxa.com/product 2012 Moxa Inc. All rights reserved. MGate MB3000 Modbus Gateway User s Manual The software described in this manual
More informationDocument Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter
Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default
More informationTRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3
TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed Apr.2014 Rev 1.3 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax:
More informationGW1000 User s Guide. Revision 1.04 Mar 30, 2008
GW1000 User s Guide Revision 1.04 Mar 30, 2008 Website: www.datalink-networks.com Tel : (604) 632-4278 / (866) 709-6390 Table of Contents 1.0 GW1000 General Operation & Applications... 3 2.0 Hardware Specifications...
More informationSerial to Ethernet Converter
Serial to Ethernet Converter User s Manual Version 1.1 2004 Infosystem Technology Corporation Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Infosystem
More informationEthernet Serial Server
Ethernet Serial Server Users Manual Eport-101, Eport-102, Eport-104, Eport108 1 INTRODUCTION... 1 1.1 FEATURES... 1 1.2 PRODUCT SPECIFICATIONS... 2 1.3 DEFAULT SETTINGS... 3 2 COMMUNICATION MODES... 4
More informationMGate MB3000 Modbus Gateway User s Manual
User s Manual Seventh Edition, May 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used
More informationTRP-C37 User s Manual
TRP-C37 User s Manual Ethernet to RS232/422/485 Converter Printed Oct. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
More informationUSR-TCP Hard version: V2.0 File version: V
Serial Device Server - RS232/RS485 to Ethernet converter USR-TCP232-300 Hard version: V2.0 File version: V1.1 2011-8-17 Serial Device Server - RS232/RS485 to Ethernet converter is an Equipment for convert
More informationCopyright Extract from Conditions of Sale Safety Warning
KD420 User Manual Copyright 2004-2013 KK Systems Ltd. No reproduction of any part of this document, in any form, is allowed without prior written permission from KKSystems Ltd. All other copyrights and
More informationTRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND
OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT
More informationIntech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RTD6 Installation Guide. The 2300 series stations are designed to
More informationCommunication adapter RS485/422 over the Ethernet ELO E222. User manual
Communication adapter RS485/422 over the Ethernet ELO E222 User manual Table Of Content: 1.0 Introduction... 3 1.1 Application... 3 2.0 How does it works?... 4 3.0 Installation... 4 3.1 Ethernet connection...
More informationDGH A3000 Configuration Guide For use with DGH Modules
DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation
More informationOperation Manual of EX9132CST-Series
Operation of EX9132CST-Series Serial to TCP/IP Converter (EX9132CST-2/ EX9132CST-RS485/ EX9132C-RS232) Version 1.0.0. 30.03.2017 Table of Contents 1 Introduction... 4 2 Overview... 5 2. 1 Package Checklist...
More informationNCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationOverview. Table of contents
1 Table of contents Overview... 1 Applications... 2 Connecting and adjusting of converter... 3 Communication parameters adjusting... 5 RealPort - virtual serial port... 12 Installing virtual serial port
More informationtsh-700 Series User Manual
tsh-700 Series User Manual Tiny Serial Port Sharer Aug. 2017 Ver. 1.6 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery
More informationWIZ220IO / WIZ220IO-EVB User s Manual (Ver. 1.0)
[ 텍스트입력 ] WIZ0IO / WIZ0IO-EVB User s Manual (Ver. 1.0) 010 WIZnet Inc. All Rights Reserved. For more information, visit our website at www.wiznet.co.kr Document History Information Revision Data Description
More informationUser Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)
User Manual Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP) FDC_PC-E_Manual_V1.0_August-2007 1 of 19 COPYRIGHT NOTICE This manua l is a publication of Future Design
More informationIntesisBox Modbus Server KNX
IntesisBox Modbus Server KNX User Manual r1.0 eng Issue date: 09/2017 Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject to change without notice. The software described
More informationRC-SV Configuration Guide (Rev 4)
Kramer Electronics, Ltd. RC-SV Configuration Guide (Rev 4) Software Version 2.1.2.69 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version, go
More informationNCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationTRP-C37M User s Manual
TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed May. 2011 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
More informationIntech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.
Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to
More informationEQ7000. User Manual. Rev 1.00
EQ7000 User Manual Rev 1.00 www.equustek.com Revision 1.00 February 27, 2009 Contents INTRODUCTION...4 ABOUT THIS MANUAL...4 INTENDED AUDIENCE...4 HARDWARE SPECIFICATIONS...5 PHYSICAL SPECIFICATIONS...5
More informationIntesisBox Modbus Server - Honeywell XLS 80
IntesisBox Server - Honeywell XLS 80 Gateway for integration of Honeywell XLS 80 fire panels into (RTU and TCP) enabled control systems. Integrate your Honeywell fire panels into your master device or
More informationMESP211 Series USER MANUAL
MESP211 Series USER MANUAL 1 Advantech B+B SmartWorx - Americas 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 Fax (815) 433-5105 Advantech B+B SmartWorx - European Headquarters Westlink Commercial
More informationDip Switch settings for 2-wire and 4-wire configuration. Schneider Electric - Division - Name Date
Dip Switch settings for 2-wire and 4-wire configuration 1 2.0 Modbus Communication Cable Connection: Use cable wiring as shown in drawing below. Communication Protocol RS422 4-wire Communication port at
More informationRC-SV Configuration Guide Revision 3
Kramer Electronics, Ltd. RC-SV Configuration Guide Revision 3 Software Version 2.1.2.32 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version,
More informationKAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual
KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G User manual Martem AS 2014 CONTENTS 1. Description...3 2. Features...3 3. Interfaces...3 4. Indication and switches...4 4.1 State LED indication...4
More informationKTA-250 Anemometer Alarm Card
Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments
More informationEGW1-IA3-MB User s Manual
www.exemys.com Rev. 0 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information
More informationIndustrial 1-port RS422/485 Modbus Gateway IMG-110T
Industrial 1-port RS422/485 Modbus Gateway IMG-110T Presentation Outlines Product Positioning Applications Product Overview Comparison Product Benefits Appendix Product Features 2 / 43 Product Positioning
More informationIPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide
VxI Power Ltd. IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide 01/12/2015 Document Number: 14970-020A Issue Number: 2 Contents 1.0 Device Overview... 2 2.0 Getting Started... 3 2.1 Connecting the Device...
More informationMODEL: GR8-EM. Communication Adaptor GR8 Series
Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to
More informationEtherSeries Modbus Gateway EMB-2 User s Guide
EtherSeries Modbus Gateway EMB-2 User s Guide Revised March 25, 2004 Firmware Version 1.4 FCC Statement This device complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC
More informationSSE232-LE Serial Server- User s Manual
www.exemys.com Rev.6 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information
More informationCanlan INSTALLATION MANUAL
Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...
More informationGW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual
GW-7472 / GW-7473 EtherNet/IP to Modbus RTU/TCP Gateway User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, starting from
More informationJetBox series Modbus Gateway User Manual
JetBox series Modbus Gateway User Manual www.korenixembedded.com 0.0.6 Copyright Notice Copyright 2012 Korenix Technology Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Information
More informationZ-2400-RB/TCP TURBO Wireless Data Links Using ZIGBEE For MicroScan Protocols.
Z-2400-RB/TCP TURBO Wireless Data Links Using ZIGBEE For MicroScan Protocols. Installation Guide. Z-2400-Base/Remote Turbo Installation Guide Index: Description. Page 3 Ordering Information. Page 3 Specifications.
More informationNetBiter I/O Extender User Manual
User Manual Part no. 0920-9999-009 IntelliCom Innovation AB Pilefeltsgatan 73 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision
More informationiopro Mirrored IO System
Ph: (877) 343-8467 Fax: (800) 303-5381 Email: info@ioselect.com iopro Mirrored IO System Quick Start Guide (Ver. 6) www.ioselect.com Page 1 Introduction This document will cover how to use the iopro family
More informationEtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X
EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...
More informationEthernet/SIOX Gateway Applicable to firmware ver 1.0
ES2 Ethernet/SIOX Gateway p 2 TELEFRANG AB TABLE OF CONTENTS Ethernet/SIOX Gateway Applicable to firmware ver 1.0 General Description The ES2 module is a Gateway between a LAN/WAN Ethernet network and
More information4.6 PT8AIIS ISOLATED ANALOG CURRENT INPUTS Description
4.6 PT8AIIS ISOLATED ANALOG CURRENT INPUTS 4.6.1 Description The PT8AIIS module is an 8 channel isolated current input module. The module uses differential inputs to reduce effects of electrical noise
More information256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client
User Manual V1.0.0 Table of Contents Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Connector pinouts... 3 1.4. Restoring factory default... 3 1.5. LED indicator... 3 1.6. CR1225 battery...
More informationTRP-C08 User s Manual
TRP-C08 User s Manual USB To RS232/422/485 Optical Isolated Converter Printed Aug. 2005 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu Street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,
More informationIndustrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature
Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature IGS-10020PT / IGS-10020HPT Quick Installation Guide Version 1.0 Table of Contents 1.
More informationSetting up a Serial to Ethernet Adapter to Work with a Siemens Milltronics Instrument and KEPServerEX
Data Communications Reference AG020716 Setting up a Serial to Ethernet Adapter to Work with a Siemens Milltronics Instrument and KEPServerEX Objective: Equipment: To communicate with a Siemens Milltronics
More informationUser Manual Anybus Serial Server
User Manual Anybus Serial Server Rev. 1.20:1 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 + 44 (0) 1908-359301 ge-sales@hms-networks.com
More informationJetBox 5630 Modbus Gateway User Manual
JetBox 5630 Modbus Gateway User Manual www.korenixembedded.com 0.0.1 Copyright Notice Copyright 2012 Korenix Technology Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Information
More informationInternational Headquarters. European Headquarters
VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_1116 Revision: March 2016 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International Headquarters
More informationEmbedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.
Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4
More informationZigBee Converter User s Manual
ZigBee Converter User s Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning
More informationTRP-C06H User s Manual
TRP-C06H User s Manual 2-Port RS-232 to RS-422/485 Isolated Converter Printed Feb.2007 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Hinge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,
More informationInternational Headquarters. European Headquarters
VLINX VESP211 SERIAL SERVER Document Name: VESP211_R002_0613 Revision: 2.0 -- February 2013 This product designed and manufactured in Ottawa, Illinois USA using domestic and imported parts by International
More informationIndustrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS T2S/IGS UP1T2S IGS P2S/IGS P4S/IGS P2T2S
Industrial L2+ Multi-Port Full Gigabit Managed Ethernet Switch IGS-5225-4T2S/IGS-5225-4UP1T2S IGS-5225-8P2S/IGS-5225-8P4S/IGS-5225-8P2T2S Quick Installation Guide Table of Contents 1. Package Contents...
More informationRemote Control SIPROTEC 4 via Ethernet-Modems 7XV585x and 7XV5655
Remote Control SIPROTEC 4 via Ethernet-Modems 7XV585x and 7XV5655 General In principle the scope of functions of Ethernet-Modems correspond to the already known analog or digital telephone modems. Instead
More informationMeter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)
Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M9813380120-A) 1.- BASIC INSTRUCTIONS 1.1.- Checks on receipt. This manual assists in the installation and handling of
More informationMGate 5118 Quick Installation Guide
MGate 5118 Quick Installation Guide Edition 1.0, December 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationPower Serial Device Server
Power Serial Device Server Overview The SED16 Serial device servers are designed to make serial devices network-ready in an instant and give your PC software direct access to serial devices from anywhere
More informationUSER MANUAL FOR GS100/GS1003G
USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...
More information# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or
EQ7000 User Manual Rev 1.04 www.equustek.com Revision 1.04 Feb 20th, 2017 #286-5489 Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: 888-387-3787 or 604-266-8547 www.equustek.com Page 1 Contents INTRODUCTION...4
More informationIntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng
IntesisBox Modbus Server KILSEN KSA-7xx User s Manual 08/2013 r1.2 eng Intesis Software S.L. 2013 All rights reserved. Information in this document is subject to change without notice. The software described
More informationSCADALink IP100 SCADA Terminal Server QUICK START GUIDE Revision 1.42 June 19, 2012
SCADA Terminal Server QUICK START GUIDE Revision 1.42 June 19, 2012 www.scadalink.com INTRODUCTION Use this Quick Start Guide to configure a SCADALink IP100. Full documentation is found under the IP100
More informationICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions
ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter
More informationNetCom 413 PRO. Contact Online. More Pictures. Klick on the thumbnails for the large picture. Overview
VS Vision Systems GmbH / Part Number 676 Features Controls 4 RS232/422/485 devices located virtually anywhere via Ethernet or Internet Secure encryption on Ethernet LAN interface 10BaseT/100BaseTx Ethernet
More informationIndustrial L2/L4 Managed Gigabit Switch. With 4-Port 802.3at PoE+ IGS P4T/IGS P4T2S. Quick Installation Guide
Industrial L2/L4 Managed Gigabit Switch With 4-Port 802.3at PoE+ IGS-4215-4P4T/IGS-4215-4P4T2S Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring the Power
More informationTRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual
TRP-C08S USB to 1 RS232 and 1 RS422/485 Isolated Converter User s Manual Printed Sep. 2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351
More informationFor more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference.
For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference. Weather Station Setup Configuring the KTA-282 Connection Description V + Power
More informationUser Manual. cmt-svr Startup Guide
User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet
More informationNetwork Video Server Quick Start Guide
Network Video Server Quick Start Guide Version 1.0.0 Table of Contents 1 Hardware Installation and Connection... 1 1.1 Check Unpacked Device... 1 1.2 About Front Panel and Rear Panel... 1 1.3 After Remove
More information3.1 I-7560 Pin Assignment and Specifications: Introduction
3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows
More informationTRP-C37M User s Manual
TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed OCT. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
More informationEthernet Interface Module
Interface Manual 1 Ethernet Interface Module SignalFire Number: ENET-DIN The SignalFire Ethernet Gateway has the following features: - Wide range DC power input. 6 to 36VDC - Power Over Ethernet (POE)
More informationUser s Manual Printed Sep Rev 1.2
TRP-C08M USB To 4 RS232/422/485 Isolated Converter User s Manual Printed Sep. 2014 Rev 1.2 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351