Preparing FRSM and MPSM Lines and Ports for Communications

Size: px
Start display at page:

Download "Preparing FRSM and MPSM Lines and Ports for Communications"

Transcription

1 CHAPTER 2 Preparing FRSM and MPSM Lines and Ports for Communications This chapter describes how to bring up physical lines and add logical ports on the FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2/B cards by using the command-line interface (CLI). These topics describe how to bring up physical lines and add logical ports to the FRSM and MPSM cards installed in PXM45/PXM1E and PXM1 platforms: Preparing for Provisioning Quickstart Provisioning Procedures General FRSM and MPSM Provisioning Procedures FRSM and MPSM cards, lines, and ports can also be configured using the Cisco WAN Manager (CWM) application. For configuration instructions, refer to the Cisco WAN Manager User s Guide, Release Bringing up physical lines and adding logical ports on FRSM and MPSM cards is described in Table 2-1. Table 2-1 Line and Port Configuration on FRSM and MPSM Cards Configuration Task Bringing up physical lines Adding logical ports Description Lines establish physical layer connectivity between a FRSM/MPSM port and the same port type (T1, for example) on another device. Frame Relay ports establish Frame Relay communications over a line to Frame Relay customer premises equipment (CPE). To eliminate redundancy and to help experienced users complete configuration tasks efficiently, this chapter provides configuration quickstart procedures. The first time you configure a line or port, use the applicable quickstart procedure to get an overview of the tasks to be performed. Then, for more detailed instructions, consult the appropriate section(s) elsewhere in the document that are called out in the quickstart procedure. As you gain experience in configuring FRSM and MPSM lines and ports, referring to a quickstart procedure may suffice for performing a particular configuration task. 2-1

2 Preparing for Provisioning Chapter 2 Tip You can get information about most CLI commands by entering the command without parameters. Ordinarily, experienced users can configure FRSM and MPSM cards using just the quickstart procedures and the online help facilities. For a detailed description of the commands used in this chapter, refer to Chapter 6, FRSM and MPSM Command Reference. Preparing for Provisioning Before you begin configuring lines and ports on FRSM and MPSM cards, you need to initialize the cards you plan to provision. The MPSM card must be configured for the interface type and service type through the use of the PXM cnfcdmode command and also requires the management of feature licenses. Then you should develop and implement a plan for the card redundancy, line redundancy, and bulk distribution options available for each service module. This plan determines how service modules and their back cards must be installed in the chassis, and how lines must connect to the cards before software configuration starts. Without a plan developed for these services, a configuration change for any of these services has the potential to interrupt service and can require substantial configuration teardown. The FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2/B cards support 1:1 card redundancy, and the FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, and MPSM-8E1-FRM cards support 1:N card redundancy and bulk distribution through the support of Service Resource Module (SRM) cards. Line redundancy is available to those service modules that support bulk distribution through use of the SRME or SRME/B card with an optical back card. For an overview of the features that the SRM card provides to the FRSM and MPSM cards, see SRM Card Services in Chapter 1, Introduction. For instructions on displaying, moving, and allocating MPSM feature licenses and managing MPSM feature license alarms, see Managing MPSM Feature Licenses in Chapter 5, Managing FRSM and MPSM Cards. For instructions on initializing cards; configuring card redundancy, line redundancy, and bulk distribution; and managing MPSM feature licenses on the PXM processor card, refer to the Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, and Cisco MGX 8830 Configuration Guide, Release 5.1, the Release s for Cisco MGX 8230, Cisco MGX 8250, and Cisco MGX 8850 (PXM1) Switches, Release , and the Cisco MGX 8850 Edge Concentrator Installation and Configuration, Release documentation. Quickstart Provisioning Procedures These quickstart tasks contain abbreviated procedures for selecting the MPSM interface and service type, moving MPSM feature licenses, and provisioning the line and port capabilities of FRSM and MPSM cards installed in Cisco MGX 8230, Cisco MGX 8250, Cisco MGX 8850 (PXM1), Cisco MGX 8850 (PXM1E/PXM45), and Cisco MGX 8830 switches: MPSM Interface and Service Configuration Quickstart Moving MPSM Feature Licenses Quickstart FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B Line Configuration Quickstart 2-2

3 Chapter 2 Quickstart Provisioning Procedures FRSM-2T3E3 and FRSM-2CT3 Line Configuration Quickstart Frame Relay Port Configuration Quickstart These procedures provide a high-level overview and serve as a procedural reminder for users already experienced in configuring MGX switches. MPSM Interface and Service Configuration Quickstart To select the interface and service type on the MPSM-8T1E1 card, perform the following steps: Step 1 Step 2 Command username <password> cnfcdmode <options> Related commands: dspcd <slot> dspcds These related commands are performed on the PXM processor card. Purpose Start a configuration session on the PXM processor card. To perform the steps in this quickstart procedure, you must log in as a user with SERVICE_GP privileges or higher. This step allows you to configure the interface and service type of the MPSM-8T1E1 card. Select the back card interface type (T1 or E1) and select the service (ATM, Frame Relay, or Circuit Emulation) this card will support. See the Selecting MPSM Interfaces and Services section that appears later in this chapter. The cnfcdmode command is performed on the PXM processor card. Moving MPSM Feature Licenses Quickstart To move MPSM feature licenses from the MPSM-8T1E1 card into the PXM license pool, perform the following steps: Step 1 Command username <password> Purpose Start a configuration session. Step 2 dspliccd View the feature licenses that have been installed on the MPSM-8T1E1 card. See the Displaying MPSM Feature Licenses section in Chapter 5, Managing FRSM and MPSM Cards. 2-3

4 Quickstart Provisioning Procedures Chapter 2 Command Purpose Step 3 movelic Move the MPSM feature licenses programmed on the MPSM-8T1E1 card to the switch license pool on the PXM processor card. See the Moving MPSM Feature Licenses section in Chapter 5, Managing FRSM and MPSM Cards. Step 4 dsplics Related commands: cnflic <options> dspliccds dspliccd <slot> dsplicalms These related commands are performed on the PXM processor card. View the MPSM feature licenses installed in the PXM license pool. See the Moving MPSM Feature Licenses section in Chapter 5, Managing FRSM and MPSM Cards. The dsplics command is performed on the PXM processor card. To install spare feature licenses into the PXM license pool, transfer feature licenses from one switch to another switch, and resolve feature license alarms, refer to the Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, and Cisco MGX 8830 Configuration Guide, Release 5.1 and the Release s for Cisco MGX 8230, Cisco MGX 8250, and Cisco MGX 8850 (PXM1) Switches, Release FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B Line Configuration Quickstart To add a line on a FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B card, perform the following steps: Step 1 Step 2 Step 3 Command username <password> addln <line> addln <line> [<interface_type>] Related commands: dsplns dspln <line> delln <line> cnfln <options> Related commands: dsplns dspln <line> delln <line> xcnfln <options> Purpose Start a configuration session. To perform the steps in this quickstart procedure, you must log in as a user with GROUP1 privileges or higher. Bring up a line. The interface_type parameter is optional for FRSM-HS2/B lines. This step establishes physical layer connectivity between an MGX switch and a Frame Relay device. See the Bringing Up Lines section that appears later in this chapter. This optional step allows you to change a line configuration when the default or existing configuration needs changing. See the Configuring FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B Lines section that appears later in this chapter. 2-4

5 Chapter 2 Quickstart Provisioning Procedures FRSM-2T3E3 and FRSM-2CT3 Line Configuration Quickstart To add a line on a FRSM-2T3E3 and FRSM-2CT3 card, perform the following steps: Step 1 Step 2 Step 3 Command username <password> addln <line> Related commands: dspds3lns dspds3ln <line> delln <line> cnfds3ln <options> Related commands: dspds3lns dspds3ln <line> delln <line> xcnfln <options> Purpose Start a configuration session. To perform the steps in this quickstart procedure, you must log in as a user with GROUP1 privileges or higher. Bring up a line. This step establishes physical layer connectivity between an MGX switch and a Frame Relay device. See the Bringing Up Lines section that appears later in this chapter. This optional step allows you to change a line configuration when the default or existing configuration needs changing. See the Configuring FRSM-2T3E3 and FRSM-2CT3 Lines section that appears later in this chapter. Frame Relay Port Configuration Quickstart Frame Relay ports connect a Cisco MGX 8230, Cisco MGX 8250, Cisco MGX 8850 (PXM1), Cisco MGX 8850 (PXM1E/PXM45), or Cisco MGX 8830 to CPE Frame Relay devices. In most cases these devices are routers. The equipment at both ends of a Frame Relay line must be configured with compatible settings in order for the link to be logically completed. To configure a Frame Relay port on a FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, FRSM-2T3E3, FRSM-2CT3, FRSM-HS2/B, MPSM-8T1-FRM, or MPSM-8E1-FRM card, perform the following steps: Step 1 Command username <password> Purpose Start a configuration session. To perform all the steps in this quickstart procedure, you must log in as a user with GROUP1 privileges or higher. 2-5

6 General FRSM and MPSM Provisioning Procedures Chapter 2 Command Step 2 addln <line> Prepare a FRSM or MPSM line for communications. See the FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B Line Configuration Quickstart, or FRSM-2T3E3 and FRSM-2CT3 Line Configuration Quickstart, both of which appears earlier in this chapter. Step 3 addport <options> Add a Frame Relay port. Related commands: dspport <port> dspports cnfport <options> xcnfport <options> Purpose This step establishes Frame Relay communications between two Frame Relay devices. See the Adding Frame Relay Ports section that appears later in this chapter. General FRSM and MPSM Provisioning Procedures These procedures and topics describe preparing FRSM and MPSM cards for communications: Selecting MPSM Interfaces and Services Displaying Lines Bringing Up Lines Configuring FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B Lines Configuring FRSM-2T3E3 and FRSM-2CT3 Lines Overview of Frame Relay Port Configuration Adding Frame Relay Ports Configuring Frame Relay Ports Selecting MPSM Interfaces and Services Use the PXM cnfcdmode command as described in the following procedure to configure MPSM-8T1E1 interfaces and services: Step 1 Step 2 Establish a configuration session using a user name with SERVICE_GP privileges or higher. Enter the cnfcdmode command using the following format: M8850_SF.7.PXM.a > cnfcdmode <slotno> <iftype> <servicetype> To use this command, the MPSM-8T1E1 card must be in the standby state with no configuration and not in a redundancy group. Table 2-2 defines the parameters for this command. 2-6

7 Chapter 2 General FRSM and MPSM Provisioning Procedures Table 2-2 cnfcdmode Command Parameters Parameter slotno iftype servicetype Description Enter the number for the slot in which the MPSM-8T1E1 card is installed. Enter a number from the following list that selects the interface type to be used with the MPSM-8T1E1: T1 Interface = 1 E1 Interface = 2 T3 Interface = 3 (Not applicable to the MPSM-8T1E1) E3 Interface = 4 (Not applicable to the MPSM-8T1E1) Enter a number from the following list that selects the service the MPSM-8T1E1 will support: Frame Relay Service = 1 ATM Service = 2 CES Service = 3 The following example shows how to configure an MPSM-8-T1E1 card to use a T1 interface and Frame Relay services: M8850_SF.8.PXM.a > cnfcdmode You are about to configure MPSM in slot 28 to : Service Type : Frame Interface Type : T1 cnfcdmode: Do you want to proceed (Yes/No)? y M8850_SF.8.PXM.a > Step 3 After you set the interface type and service type, the card resets and the card state changes from Standby/Active to Active/Active. You can verify that the PXM cnfcdmode command has been run by looking at the Inserted Card row of the PXM dspcd <slot> command display. Before configuring the MPSM-8-T1E1 for Frame Relay services, the Inserted Card row displays the generic name MPSM-8T1E1. After configuration, the generic name changes to a specific name such as MPSM-8T1-FRM or MPSM-8E1-FRM. Table 2-3 lists the MPSM-8T1E1 card names and what they mean when they appear in the PXM dspcd and dspcds command displays. Table 2-3 MPSM-8-T1E1 Card Names in the PXM dspcd and dspcds Command Displays Card Name MPSM-8T1E1 MPSM-8T1-ATM MPSM-8E1-ATM MPSM-8T1-CES MPSM-8E1-CES MPSM-8T1-FRM MPSM-8E1-FRM Description No service configured on card. Configured for ATM services and T1 interfaces. Configured for ATM services and E1 interfaces. Configured for Circuit Emulation services and T1 interfaces. Configured for Circuit Emulation services and E1 interfaces. Configured for Frame Relay services and T1 interfaces. Configured for Frame Relay services and E1 interfaces. 2-7

8 General FRSM and MPSM Provisioning Procedures Chapter 2 For more information on use of the PXM cnfcdmode command, refer to the Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, and Cisco MGX 8830 Configuration Guide, Release 5.1, the Cisco MGX 8850 (PXM45/PXM1E), Cisco MGX 8950, and Cisco MGX 8830 Command Reference Guide, Release 5.1, the Release s for Cisco MGX 8230, Cisco MGX 8250, and Cisco MGX 8850 (PXM1) Switches, Release , and the Cisco MGX 8850 Edge Concentrator Installation and Configuration, Release documentation. Displaying Lines To display the current configuration of lines on a FRSM or MPSM card, perform the following steps: Step 1 Step 2 Establish a configuration session using a user name with GROUP 1 privileges or higher. To display the current configuration for all lines on FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B cards, enter the dsplns command: PXM1E_SJ.1.1.FRSM.a > dsplns Line Conn Type Status/Coding Length XmtClock Alarm Stats Type Source Alarm RJ-48 dsx1esf Ena/dsx1B8ZS ft LocalTim Yes No 1.2 RJ-48 dsx1esf Ena/dsx1B8ZS ft LocalTim Yes No 1.3 RJ-48 dsx1esf Ena/dsx1B8ZS ft LocalTim Yes No 1.4 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim 1.5 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim 1.6 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim 1.7 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim 1.8 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim LineNumOfValidEntries: 8 Step 3 The dsplns command report can be different for different card types. The alarm state indicates whether the line is communicating with a remote switch. When the alarm state is blank or is reported as No, it indicates that the physical devices at each end of the line have established physical layer communications. Higher-layer connectivity is established later when ports are configured on the FRSM and MPSM card lines. To display the current configuration for all T3 or E3 lines on FRSM-2T3E3 and FRSM-2CT3 cards, enter the dspds3lns command: PXM1E_SJ.1.20.VHS2E3.a > dspds3lns Line Type Status/Coding Length XmtClock Alarm Stats Source Alarm c-bit Enable/dsx3B3ZS LT225ft localclk Yes Yes 4.2 c-bit Disabl/dsx3B3ZS LT225ft localclk LineNumOfValidEntries: 2 PXM1E_SJ.1.20.VHS2E3.a > 2-8

9 Chapter 2 General FRSM and MPSM Provisioning Procedures Step 4 To display the current configuration for all 56 channelized T1 lines on the FRSM-2CT3 card, enter the dsplns command. M8850_SF.1.9.VHS2CT3.a > dsplns Line Type Status XmtClock LoopBack Alarm Stats Source Alarm dsx1esf Ena LocalTimin NoLoop No No 9.2 dsx1esf Ena LocalTimin NoLoop No No 9.3 dsx1esf Ena LocalTimin NoLoop No No 9.4 dsx1esf Ena LocalTimin NoLoop No No 9.5 dsx1esf Ena LocalTimin NoLoop No No 9.6 dsx1esf Ena LocalTimin NoLoop No No 9.7 dsx1esf Ena LocalTimin NoLoop No No 9.8 dsx1esf Ena LocalTimin NoLoop No No 9.9 dsx1esf Ena LocalTimin NoLoop No No 9.10 dsx1esf Ena LocalTimin NoLoop No No 9.11 dsx1esf Ena LocalTimin NoLoop No No 9.12 dsx1esf Ena LocalTimin NoLoop No No 9.13 dsx1esf Ena LocalTimin NoLoop No No 9.14 dsx1esf Ena LocalTimin NoLoop No No 9.15 dsx1esf Ena LocalTimin NoLoop No No 9.16 dsx1esf Ena LocalTimin NoLoop No No 9.17 dsx1esf Ena LocalTimin NoLoop No No 9.18 dsx1esf Ena LocalTimin NoLoop No No 9.19 dsx1esf Ena LocalTimin NoLoop No No 9.20 dsx1esf Ena LocalTimin NoLoop No No 9.21 dsx1esf Ena LocalTimin NoLoop No No 9.22 dsx1esf Ena LocalTimin NoLoop No No 9.23 dsx1esf Ena LocalTimin NoLoop No No 9.24 dsx1esf Ena LocalTimin NoLoop No No 9.25 dsx1esf Ena LocalTimin NoLoop No No 9.26 dsx1esf Ena LocalTimin NoLoop No No 9.27 dsx1esf Ena LocalTimin NoLoop No No 9.28 dsx1esf Ena LocalTimin NoLoop No No 9.29 dsx1esf Dis LocalTimin NoLoop 9.30 dsx1esf Dis LocalTimin NoLoop 9.31 dsx1esf Dis LocalTimin NoLoop 9.32 dsx1esf Dis LocalTimin NoLoop 9.33 dsx1esf Dis LocalTimin NoLoop 9.34 dsx1esf Dis LocalTimin NoLoop 9.35 dsx1esf Dis LocalTimin NoLoop 9.36 dsx1esf Dis LocalTimin NoLoop 9.37 dsx1esf Dis LocalTimin NoLoop 9.38 dsx1esf Dis LocalTimin NoLoop 9.39 dsx1esf Dis LocalTimin NoLoop 9.40 dsx1esf Dis LocalTimin NoLoop 9.41 dsx1esf Dis LocalTimin NoLoop 9.42 dsx1esf Dis LocalTimin NoLoop 9.43 dsx1esf Dis LocalTimin NoLoop 9.44 dsx1esf Dis LocalTimin NoLoop 9.45 dsx1esf Dis LocalTimin NoLoop 9.46 dsx1esf Dis LocalTimin NoLoop 9.47 dsx1esf Dis LocalTimin NoLoop 9.48 dsx1esf Dis LocalTimin NoLoop 9.49 dsx1esf Dis LocalTimin NoLoop 9.50 dsx1esf Dis LocalTimin NoLoop 9.51 dsx1esf Dis LocalTimin NoLoop 2-9

10 General FRSM and MPSM Provisioning Procedures Chapter dsx1esf Dis LocalTimin NoLoop 9.53 dsx1esf Dis LocalTimin NoLoop 9.54 dsx1esf Dis LocalTimin NoLoop 9.55 dsx1esf Dis LocalTimin NoLoop 9.56 dsx1esf Dis LocalTimin NoLoop LineNumOfValidEntries: 56 M8850_SF.1.9.VHS2CT3.a > Step 5 To display the current configuration for a particular line, enter the dspln command in the format shown below: PXM1E_SJ.1.25.FRSM.a > dspln 2 LineNum: 2 LineConnectorType: RJ-48 LineType: dsx1esf LineEnable: Enabled LineCoding: dsx1b8zs LineLength: ft LineXmtClockSource: LocalTiming LineLoopbackCommand: NoLoop LineSendCode: NoCode LineUsedTimeslotsBitMap: 0x400 LineLoopbackCodeDetection: codedetectdisabled LineBertEnable: Disable LineNumOfValidEntries: 8 This sample dspln command shows the configuration parameters of a T1 line for a FRSM-8T1-C card. Bringing Up Lines Installing a FRSM or MPSM card can add up to 8 physical lines to your switch. You must bring up a line before you can configure it or before you can provision Frame Relay services on the line. Before a line is brought up, or after it is brought down, the switch does not monitor the line. Prior to bringing up a line, the FRSM or MPSM port status light for the line is unlit, and all line alarms are cleared. When you bring up a line on a FRSM or MPSM card, the switch starts monitoring the line. The FRSM or MPSM card port status light turns green when physical layer connectivity is established with a remote device. If a physical layer communications problem occurs, the port status light turns red and an alarm is reported. Tip To minimize the number of alarms reported and to reduce the frequency of failed port status lamps (which display red), it is recommended that you keep lines down until they are actually needed for communication. 2-10

11 Chapter 2 General FRSM and MPSM Provisioning Procedures To bring up a FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, FRSM-2T3E3, FRSM-2CT3, FRSM-HS2/B, MPSM-8T1-FRM, or MPSM-8E1-FRM line on a Cisco MGX switch, perform the following steps: Step 1 Step 2 Step 3 Step 4 Establish a configuration session using a user name with GROUP 1 privileges or higher. Select the FRSM or MPSM card on which you want to bring up a line by issuing the cc command, as shown below: PXM1E_SJ.1.7.PXM.a > cc <slotnumber> Replace the <slotnumber> parameter with the number of the slot in which the FRSM card is installed. Enter the dsplns command to check which lines on the card are available to bring up. To activate a line on the FRSM or MPSM card, enter the addln command as shown below: PXM1E_SJ.1.1.FRSM.a > addln <line> [<interface_type>] Replace the <line> parameter with the number corresponding to the back card port to which the line is connected. Table 2-4 lists the valid line numbers for the FRSM and MPSM cards. The optional <interface_type> parameter applies only when you are using the FRSM-HS2/B card with the 12IN1-8S back card. The default interface type for the 12IN1-8S back card is V.35. To specify the interface type as X.21, replace the <interface_type> with a value of 2. Table 2-4 FRSM and MPSM Card Types Front Card Valid Line Numbers FRSM-8T1 1 to 8 FRSM-8T1-C 1 to 8 FRSM-8E1 1 to 8 FRSM-8E1-C 1 to 8 MPSM-8T1-FRM 1 to 8 MPSM-8E1-FRM 1 to 8 FRSM-2CT3 1 to 2 FRSM-2T3E3 1 to 2 FRSM-HS2/B 1 to 2 with HSSI 1 to 8 with 12IN1-8S 2-11

12 General FRSM and MPSM Provisioning Procedures Chapter 2 Step 5 Enter the dsplns command to verify that the line has been successfully brought up. PXM1E_SJ.1.1.FRSM.a > dsplns Line Conn Type Status/Coding Length XmtClock Alarm Stats Type Source Alarm RJ-48 dsx1esf Ena/dsx1B8ZS ft LocalTim Yes No 1.2 RJ-48 dsx1esf Ena/dsx1B8ZS ft LocalTim Yes No 1.3 RJ-48 dsx1esf Ena/dsx1B8ZS ft LocalTim Yes No 1.4 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim 1.5 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim 1.6 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim 1.7 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim 1.8 RJ-48 dsx1esf Dis/dsx1B8ZS ft LocalTim LineNumOfValidEntries: 8 When a line has been successfully brought up, the status column reports the line status as Enable or Ena. Lines that have not been brought up are reported as Disable or Dis in the status column. Configuring FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B Lines All line types are brought up with a default configuration, which may or may not be compatible with the Frame Relay device to which you are connecting. When configuring a FRSM or MPSM card line, you must ensure that the devices at both ends of the connection are using the same configuration parameters on the shared line. To configure lines on FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B cards, perform the following steps: Step 1 Step 2 Establish a configuration session using a user name with GROUP 1 privileges or higher. If you do not know the line number you want to configure on the FRSM or MPSM card, enter the dsplns command to display the current configuration of all lines on the card: PXM1E_SJ.1.25.FRSM.a > dsplns Remember, you cannot configure a line until you have brought it up. See the Bringing Up Lines section. 2-12

13 Chapter 2 General FRSM and MPSM Provisioning Procedures Step 3 To display the configuration information for the particular line that you want to configure, enter the dspln command in the format shown below: PXM1E_SJ.1.11.VHSHS2B.a > dspln 1 LineNum: 1 LineEnable: Modify LineType: DCE LineRate: bps LineLoopbackCommand: v35metallic LineSendCode: NoCode LineLoopbackCodeDetection: codedetectenabled LineClockType: noninvertedandnotlooped LineInterfaceType: X.21 DTEClkFrequencyThreshold: 3 LineRateVariaton: 0 ppm LineNumOfValidEntries: 8 This sample dspln command shows the configuration parameters of a line on a FRSM-HS2/B card. Step 4 Step 5 To configure a line on a FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, or MPSM-8E1-FRM card, enter a cnfln command in the format shown below: PXM1E_SJ.1.25.FRSM.a > cnfln <line_num> <line_code> <line_len> <clk_src> [E1-signalling T1-Linetype] Table 2-5 lists and describes the parameters that you use in configuring T1 and E1 lines on a FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, or MPSM-8E1-FRM card. To configure a line on a FRSM-HS2/B card, enter a cnfln command in the format shown below: PXM1E_SJ.1.11.VHSHS2B.a > cnfln <line_num> <line_type> <serial_line_rate> [-intrtyp <interface_type>] [-freqth <dte_freq_thr>] Table 2-5 lists and describes the parameters that you use in configuring lines on a FRSM-HS2/B card. Table 2-5 Parameter line_num line_code Line Parameters for cnfln Command Description Enter the number of the line you want to configure. Use the dsplns command to display the available lines. Select the line coding: B8ZS (T1) = 2 HDB3 (E1) = 3 AMI (T1/E1) =

14 General FRSM and MPSM Provisioning Procedures Chapter 2 Table 2-5 Line Parameters for cnfln Command (continued) Parameter line_len clk_src E1-signalling, T1-Linetype line_type serial_line_rate Description Enter the length of the line: T1 range: 0 to 131 feet = to 262 feet = to 393 feet = to 524 feet = to 655 feet = 14 >655 feet = 15 E1 (with SMB line module) = 8 E1 (with RJ48 line module) = 9 Dsx1 clock source. 1 = loop clock 2 = local clock This option selects E1 signalling methods or T1 line types. Enter the keyword for the signalling combination listed below: E1 signalling methods: CAS, no CRC = CAS CAS with CRC = CAS_CRC CCS, no CRC = CCS CCS, with CRC = CCS_CRC Clear E1 = CLEAR T1 Line types: dsx1 ESF = ESF dsx1 D4 = D4 For FRSM-2CT3 cards, select the line type from the following: 1 = dsx1 ESF 2 = dsx1 D4 For FRSM-HS2/B cards, select the line type from the following: DTE = 1 DCE = 2 DTE_ST (V.35 only) = 3 Specify a serial line rate from the following ranges in multiples of 1000 if greater than bps: HSSI: 2400 to bps V.35/X.21: 2400 to bps 2-14

15 Chapter 2 General FRSM and MPSM Provisioning Procedures Table 2-5 Parameter -intrtyp -freqth Line Parameters for cnfln Command (continued) Description This option selects the interface type when the MGX-12IN1-8S back card is used with the FRSM-HS2/B card. Select from the following options: X.21 = 2 V.35 = 3 (default) This option sets the DTE/DTE ST clock threshold. The range is 1 to 50 percent of the Serial Line Rate. The default value is 3 percent. Step 6 To verify the line configuration changes made above, enter the dspln command for the appropriate line. When configuring E1 signalling methods using the cnfln command, Table 2-6 shows the corresponding El line type displayed in the output of the dspln and dsplns commands. Table 2-6 E1 Signalling Line Types E1 Signalling Method CAS, no CRC CAS, with CRC CCS, no CRC CCS, with CRC Clear E1 Line Type In Display Line(s) Command dsx1e1mf dsx1e1mfcrc dsx1e1 dsx1e1crc dsx1e1clear The xcnfln command may also be used to configure lines on the FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-HS2/B cards. For more information on the use of this command, see Chapter 6, FRSM and MPSM Command Reference. Configuring FRSM-2T3E3 and FRSM-2CT3 Lines All line types are brought up with a default configuration, which may or may not be compatible with the Frame Relay device to which you are connecting. When configuring a FRSM card line, you must ensure that the devices at both ends of the connection are using the same configuration parameters on the shared line. When configuring FRSM-2CT3 lines, in addition to the two channelized DS3 lines, 56 channelized DS1 lines may be configured. To configure lines on FRSM-2T3E3 and FRSM-2CT3 cards, perform the following steps: Step 1 Step 2 Establish a configuration session using a user name with GROUP 1 privileges or higher. If you do not know the line number you want to configure on the FRSM card, enter the dspds3lns command to display the current configuration of all lines on the card: PXM1E_SJ.1.20.VHS2E3.a > dspds3lns 2-15

16 General FRSM and MPSM Provisioning Procedures Chapter 2 Line Type Status/Coding Length XmtClock Alarm Stats Source Alarm c-bit Enable/dsx3B3ZS LT225ft localclk Yes Yes 4.2 c-bit Disabl/dsx3B3ZS LT225ft localclk LineNumOfValidEntries: 2 Step 3 Remember that you cannot configure a line until you have brought it up. See the Bringing Up Lines section. To display the configuration information for the particular line that you want to configure, enter a dspds3ln command in the format shown below: PXM1E_SJ.1.20.VHS2E3.a > dspds3ln 1 LineNum: 1 LineEnable: Enabled LineType: c-bit LineCoding: dsx3b3zs LineLength: LT225ft LineOOFCriteria: 3 out of 8 LineAIScBitsCheck: Ignore C-bits LineLoopbackCommand: NoLoop LineRcvFEACValidation: 4 out of 5 FEAC codes LineXmitClockSource: localclk LineEqualizer: internal equalizer LineNumOfValidEntries: 2 Step 4 This sample dspds3ln command shows the configuration parameters of a E3 line for a FRSM-2T3E3 card. To configure T3 and E3 lines on FRSM-2T3E3 and FRSM-2CT3 cards, enter the cnfds3ln command in the format shown below: PXM1E_SJ.1.20.VHS2E3.a > cnfds3ln <line_num> <line_type> <line_len> <clk_src> Table 2-7 lists and describes the parameters that you use in configuring T3 and E3 lines on a FRSM card. Table 2-7 Parameter line_num line_type Line Parameters for cnfds3ln Command Description Enter the number of the line you want to configure. Use the dspds3lns command to display the available lines. Type of line to be configured. 1 = C-bit parity 2 = g832_g804 3 = M13 4 = g

17 Chapter 2 General FRSM and MPSM Provisioning Procedures Table 2-7 Parameter line_len clk_src Line Parameters for cnfds3ln Command (continued) Description Length of line. 1 = less than 225 feet 2 = greater than 225 feet DSX3 clock source. 1 = backplane clock (2E3 only) 2 = recovery clock (2T3 and 2E3 only) 3 = local clock (2CT3, 2T3, and 2E3) Step 5 Step 6 To configure the channelized T1 lines on the FRSM-2CT3 card, enter the cnfln command in the format shown below: M8850_SF.1.9.VHS2CT3.a > cnfln <line_num> <line_type> <clk_src> Table 2-5 lists and describes the parameters that you use in configuring T1 lines on a FRSM card. To verify the line configuration changes made above, enter the dspds3ln or dspln command for the appropriate line. The xcnfln command may also be used to configure lines on FRSM-2T3E3 and FRSM-2CT3 cards. For more information on the use of this command, see Chapter 6, FRSM and MPSM Command Reference. Overview of Frame Relay Port Configuration The Bringing Up Lines section that appears earlier in this chapter describes how to bring up physical lines by specifying the correct line port number. Line ports correspond to the line connectors on the back cards of Cisco MGX 8230, Cisco MGX 8250, Cisco MGX 8850 (PXM1), Cisco MGX 8850 (PXM1E/PXM45), or Cisco MGX 8830 switches. Bringing up a line establishes physical layer connectivity between two network devices. When you add a Frame Relay port to a line, you enable Frame Relay communications by means of that line. Regardless of the card type or physical characteristics of a port (speed, timeslots, and so on), each port can be configured as the following: Frame Relay port. This is a port that sends and receives standard Frame Relay frames as defined by ITU-T Q.922. Multiple virtual circuits (VCs) can terminate on a single Frame Relay port and are differentiated by their data-link connection identifiers (DLCIs). Frame-based user-network interface (FUNI) ports. This is a port that sends and receives standard FUNI frames. Based on the three modes of ATM DXI, FUNI was developed to provide an ATM UNI in a frame format similar to Frame Relay frames. FUNI frames use the SAR functionality found in the ATM network and does not use the interworking function (IWF) for mapping and encapsulation functions. Like a Frame Relay port, a FUNI port supports SVCs, fractional T1s, multiple virtual circuits (VCs) terminating on a single Frame Relay port and are differentiated by their data-link connection identifiers (DLCIs). Unlike ATM DXI, an ATM CSU/DSU is not required. 2-17

18 General FRSM and MPSM Provisioning Procedures Chapter 2 Frame Forwarding port. This is a port that sends and receives frame-based traffic that is similar to Frame Relay frames such as HDLC, SDLC, and X.25 over Frame Relay interfaces. Application examples include routers interconnected by means of PPP, mainframes or hosts connected by X.25/HDLC, SNA/SDLC links, and video CODECs that use a frame-based protocol. Frame Forwarding is often used for the aggregation of point-to-point (PPP) traffic into an ATM network, then exiting the ATM network through an ATM interface over multiple VCs into routers supporting PPP over ATM. Frame Forwarding features include: No translation or mapping is attempted between the frame header bits and ATM layer EFCI and CLP bits. Because the port is unable to read the address and control information in the frame, all traffic must be forwarded to a single destination frame forwarding port. Only one frame forwarding VC is allowed per port. If a connection is set up, all frames are routed to and from that connection, otherwise the frame is discarded. A single set of Frame Relay traffic access parameters (for example, CIR) is configured for the logical port in frame forwarding mode. All arriving frames are treated as if they arrived without a set DE bit. If the frame is determined to exceed committed rate (exceeding CIR), the CLP of all cells associated with that frame is set to indicate low priority. If the frame exceeds the total rate allowed for committed and uncommitted traffic, the frame is discarded. Support for PPP encapsulation over AAL5 and frame is based on RFC 1483 and RFC The FRSM-8T1-C, FRSM-8E1-C, MPSM-8T1-FRM, and MPSM-8E1-FRM cards support channelized T1 or E1 Frame Relay ports. The channelized 8-port FRSM or MPSM cards can support up to 24 DS0 Frame Relay ports per T1 line and up to 31 DS0 Frame Relay ports per E1 line. At the customer premises site, a Frame Relay Access Device (FRAD) is attached to a time-division multiplexer (TDM) that aggregates multiple subrate traffic streams onto a single T1 or E1 line. Channelized ports are associated with one or more consecutive timeslots on the line. The FRSM-2CT3 card supports both channelized DS3 lines and channelized DS1 lines. Each channelized DS3 line supports 28 channelized DS1 lines providing a total of 56 channelized DS1 lines per card. Although each channelized DS1 line can support up to 24 DS0 Frame Relay ports per T1 line, the maximum amount of Frame Relay ports that can be configured per FRSM-2CT3 card is 256 logical ports. The FRSM-8T1 and FRSM-8E1 cards support fractional Frame Relay ports. On a fractional (unchannelized) FRSM, each line can support only a single port. The end-user equipment either uses the entire bandwidth of the T1 or E1 interface, or uses multiple timeslots on the T1 or E1 line. Like channelized Frame Relay ports, fractional ports are defined by consecutive timeslots on the line. The FRSM-HS2/B card supports serial Frame Relay ports. A serial port is associated with a single line, and its speed is defined by the line rate. Although a T3 or E3 line is not strictly serial, the FRSM-2T3E3 card supports port provisioning like other serial ports. Adding Frame Relay Ports To add a Frame Relay port to a line, perform the following steps: Step 1 Step 2 Establish a configuration session using a user name with GROUP1 privileges or higher. Determine the line number on which you intend to add the Frame Relay port. To do so, enter the dsplns command for FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, FRSM-2CT3, and FRSM-HS2/B cards, or enter the dspds3lns command for FRSM-2T3E3 cards. 2-18

19 Chapter 2 General FRSM and MPSM Provisioning Procedures Step 3 Verify that the port number you want to use is not already in use. To display a list of the configured ports on a FRSM or MPSM card, enter the following command: PXM1E_SJ.1.30.FRSM.a > dspports Port Ena/Speed EQServ SignalType T391 T392 N391 N392 N393 Type Alarm ELMI Ratio Add/1536k 1 NoSignalling framerel No Off Add/1536k 1 NoSignalling framerel No Off Add/1536k 1 NoSignalling framerel No Off Add/1536k 1 NoSignalling framerel Yes Off Number of ports: 4 PortDs0UsedLine1: 0x00ffffff PortDs0UsedLine2: 0x00ffffff PortDs0UsedLine3: PortDs0UsedLine4: PortDs0UsedLine5: PortDs0UsedLine6: PortDs0UsedLine7: 0x00ffffff PortDs0UsedLine8: 0x00ffffff PortNumNextAvailable: 3 This example shows the command display for a FRSM-8T1-C card. This command displays all the port numbers configured on the FRSM card in the Port column. The port numbers in the Port column appear in the format slot.line.port, so the port number is the number that appears after the last period. When you add a port, you must specify a unique port number. For example, if port number 2 is assigned to line 2, you cannot use port 2 on any other line on that FRSM card. The MPSM-8T1-FRM, MPSM-8E1-FRM, FRSM-8T1-C, FRSM-8E1-C, and FRSM-2CT3 cards support multiple ports on the same line. You can add just one port per line for the FRSM-8T1, FRSM-8E1, FRSM-2T3E3, and FRSM-HS2/B cards. Step 4 Step 5 Step 6 To add a Frame Relay port to a FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, or FRSM-2CT3 card, enter the following command: PXM1E_SJ.1.30.FRSM.a > addport <port_num> <line_num> <ds0_speed> <begin_slot> <num_slot> <port_type> [lmi_autosense] Table 2-8 lists and describes the addport command parameters. To add a Frame Relay port to an MPSM-8T1-FRM or MPSM-8E1-FRM card, enter the following command: PXM1E_SJ.1.30.MPSM8T1.FRM.a > addport <port_num> <line_num> <ds0_speed> <begin_slot> <num_slot> <port_type> [lmi_autosense] LMI autosense on the MPSM-8T1-FRM or MPSM-8E1-FRM cards applies to Release 5.1 and above. Table 2-8 lists and describes the addport command parameters. To add a Frame Relay port to a FRSM-2T3E3 or FRSM-HS2/B card, enter the following command: PXM1E_SJ.1.30.FRSM.a > addport <port_num> <line_num> <port_type> [lmi_autosense] Table 2-8 lists and describes the addport command parameters. 2-19

20 General FRSM and MPSM Provisioning Procedures Chapter 2 Table 2-8 Parameters for the addport Command Parameter or Option port_num line_num ds0_speed Description Port number for the Frame Relay service. The port number range varies with the card type: FRSM-8T1, FRSM-8T1-C, MPSM-8T1-FRM range: FRSM-8E1, FRSM-8E1-C, MPSM-8E1-FRM range: FRSM-2T3E3 range: 1 2 FRSM-2CT3 range: (Channelized T1s) FRSM-HS2/B range: 1 2 with HSSI back card FRSM-HS2/B range: 1 8 with 12IN1-8S back card Tip Since the non-channelized FRSM-8T1 and FRSM-8E1 cards support only one port per line, you might want to limit the port numbers to 1-8 for easier identification. On the FRSM-2CT3, FREEDM chip resources are distributed across the two DS3 lines. Use the dspfdminfo command to monitor the allocation of these resources when adding ports to the channelized DS1 lines. Line number to which the port definition applies. To display the lines that have been added, enter the dsplns or dspds3lns command. You cannot add a port to a line unless the Status/Coding column shows that the line is enabled (Ena). The line number range varies with the card type: FRSM-8T1, FRSM-8T1-C, MPSM-8T1-FRM range: 1 8 FRSM-8E1, FRSM-8E1-C, MPSM-8E1-FRM range: 1 8 FRSM-2T3E3 range: 1 2 FRSM-2CT3 range: 1-56 (Channelized T1s) FRSM-HS2/B range: 1 2 with HSSI back card FRSM-HS2/B range: 1 8 with 12IN1-8S back card This option applies only to FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-2CT3 (channelized T1) ports and sets the bit rate as either 56 Kbps or 64 Kbps for the DS0: 1 = 56 Kbps 2 = 64 Kbps When adding a port to an E1 line configured with CLEAR signalling, use only the 64 Kbps option. 2-20

21 Chapter 2 General FRSM and MPSM Provisioning Procedures Table 2-8 Parameters for the addport Command (continued) Parameter or Option begin_slot num_slot port_type Description This option applies only to FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM and FRSM-2CT3 (channelized T1) ports and selects the starting DS0 time slot for port communications within the T1 or E1 frame. Valid time slot numbers are: FRSM-8T1, FRSM-8T1-C, MPSM-8T1-FRM, FRSM-2CT3 range: 1 24 FRSM-8E1, FRSM-8E1-C, MPSM-8E1-FRM range: Tip With CAS line signalling: 2 16, (Slot 1 is reserved for framing and slot 17 is reserved for signalling) With CCS line signalling: 2 32 (Slot 1 is reserved for framing) With CLEAR line signalling: 1 The non-channelized FRSM-8T1 and FRSM-8E1 cards support fractional frame relay ports and only one port per line. If you want to use the full bandwidth of the line, you should enter 1 (for the FRSM-8T1 or FRSM-8E1 with CLEAR signalling) or 2 (for the FRSM-8E1 with CAS or CCS signalling) for the starting time slot. This option applies only to FRSM-8T1, FRSM-8T1-C, FRSM-8E1, FRSM-8E1-C, MPSM-8T1-FRM, MPSM-8E1-FRM, and FRSM-2CT3 (channelized T1) ports and determines the number of consecutive DS0 time slots for this port within the T1 or E1 frame. Valid time slot numbers are: FRSM-8T1, FRSM-8T1-C, MPSM-8T1-FRM, FRSM-2CT3 range: 1 24 FRSM-8E1, FRSM-8E1-C, MPSM-8E1-FRM range: Tip With CAS line signalling: 1-30 With CCS line signalling: 1-31 With CLEAR line signalling: 32 The non-channelized FRSM-8T1 and FRSM-8E1 cards support only one port per line. If you want to use the full bandwidth of the line, you should enter the maximum time slot number (either 24, 30, 31, or 32). (E1 lines with CLEAR line signalling support only the full 32 time slots.) Type of service as Frame Relay, FUNI, or frame forwarding. 1 = Frame Relay UNI or NNI 2 = ATM Forum FUNI mode 1A (AAL5 only) 3 = Frame forwarding (no translation or mapping of header contents, CRC evaluated) 2-21

22 General FRSM and MPSM Provisioning Procedures Chapter 2 Table 2-8 Parameters for the addport Command (continued) Parameter or Option lmi_autosense Description LMI autosense. With LMI autosense enabled the frame relay port will detect and configure its LMI signalling type to that of the LMI signalling type configured on the attached CPE. If LMI autosense is set to manual, the user must configure the LMI signalling type by using the cnfport or xcnfport commands. 1 = Manual (default) 2 = AutoSense LMI autosense is supported only on UNI frame relay connections, and the range of DLCIs supported is LMI autosense is supported on MPSM-8T1-FRM and MPSM-8E1-FRM cards in switches running Release 5.1 or higher. The following addport command example defines Frame Relay port 1 on T1 line 1 in slot 11 with LMI autosense. Because this is a non-channelized card, slots 1 through 24 are assigned to this port. PXM1E_SF.1.11.FRSM.a > addport The next addport command example defines Frame Relay port 1 on the channelized T1 line 1 in slot 30 with LMI autosense. Slots 1 through 4 are assigned to port 1. PXM1E_SJ.1.30.FRSM.a > addport Step 7 To display the configuration information for a specific port, enter the following command: PXM1E_SJ.1.25.FRSM.a > dspport <port> Replace the <port> parameter with the number assigned to the port during configuration. The following example shows the output of a dspport command for port number 8: PXM1E_SJ.1.25.FRSM.a > dspport 8 SlotNum: 25 PortLineNum: 8 PortNum: 8 PortRowStatus: Add PortDs0Speed: 56k PortDs0ConfigBitMap(1stDS0): 0xffffff(1) PortEqueueServiceRatio: 1 PortFlagsBetweenFrames: 1 PortSpeed: 1344kbps PortLmiSigConfMethod: Autosense SignallingProtocolType: NoSignalling AsynchronousMsgs: UPD_UFS disabled T391LineIntegrityTimer: 10 T392PollingVerificationTimer: 15 N391FullStatusPollingCounter: 6 N392ErrorThreshold: 3 N393MonitoredEventCount: 4 EnhancedLmi: Off PortState: FailedDuetoLineFailure PortSignallingState: No Signalling Failure CLLMEnableStatus: Disable CLLMxmtStatusTimer: 0 porttype: funi-mode-1a 2-22

23 Chapter 2 General FRSM and MPSM Provisioning Procedures PortIngrPercentUtil: 0 PortEgrPercentUtil: 0 PortOversubscribed: False PortSvcStatus: Disable PortSvcInUse: Not In-Use PortSvcShareLcn: Card-based PortSvcLcnLow: 0 PortSvcLcnHigh: 0 PortSvcDlciLow: 0 PortSvcDlciHigh: 0 PortDs0UsedLine1: PortDs0UsedLine2: PortDs0UsedLine3: PortDs0UsedLine4: PortDs0UsedLine5: PortDs0UsedLine6: PortDs0UsedLine7: PortDs0UsedLine8: 0x00ffffff PortNumNextAvailable: 1 Tip To delete the port configuration, enter the delport command. For more information about this command, refer to Chapter 5, Managing FRSM and MPSM Cards, and Chapter 6, FRSM and MPSM Command Reference. Configuring Frame Relay Ports When Frame Relay ports are added some of the port parameters are in a default configuration which may or may not be compatible with the Frame Relay device to which you are connecting. When configuring a Frame Relay port, you must ensure that the devices at both ends of the connection are using the same port configuration parameters in order for communications to be successful. When configuring a Frame Relay port the cnfport command is used. Configuring the LMI signalling type can either be done manually, or by use of the LMI autosense option. With LMI autosense enabled the frame relay port will detect and configure its LMI signalling type to that of the LMI signalling type configured on the attached CPE. LMI autosense is supported on MPSM-8T1-FRM and MPSM-8E1-FRM cards in switches running Release 5.1 or higher. 2-23

24 General FRSM and MPSM Provisioning Procedures Chapter 2 To configure Frame Relay ports on FRSM and MPSM cards, perform the following steps: Step 1 Step 2 Establish a configuration session using a user name with GROUP1 privileges or higher. If you do not know the port number you want to configure on the FRSM or MPSM card, enter the dspports command to display a list of the currently configured ports: M8850_SF.1.12.FRSM.a > dspports Port Ena/Speed EQServ SignalType T391 T392 N391 N392 N393 Type Alarm ELMI Ratio Add/1536k 1 StrataLMI framerel No Off Add/1536k 1 StrataLMI framerel No Off Number of ports: 2 PortDs0UsedLine1: 0x00ffffff PortDs0UsedLine2: 0x00ffffff PortDs0UsedLine3: PortDs0UsedLine4: PortDs0UsedLine5: PortDs0UsedLine6: PortDs0UsedLine7: PortDs0UsedLine8: PortNumNextAvailable: 3 Step 3 This example shows the output of the dspports command on a FRSM-8T1-C card. This command displays all the port numbers configured on the FRSM card in the Port column. The port numbers in the Port column appear in the format slot.line.port, so the port number is the number that appears after the last period. To display the configuration information for the particular port that you want to configure, enter the following command: PXM1E_SJ.1.25.FRSM.a > dspport <port> The following example shows the output of a dspport command for port number 1: M8850_SF.1.12.FRSM.a > dspport 1 SlotNum: 12 PortLineNum: 1 PortNum: 1 PortRowStatus: Add PortDs0Speed: 64k PortDs0ConfigBitMap(1stDS0): 0xffffff(1) PortEqueueServiceRatio: 1 PortFlagsBetweenFrames: 1 PortSpeed: 1536kbps PortLmiSigConfMethod: Autosense SignallingProtocolType: StrataLMI AsynchronousMsgs: UPD_UFS disabled T391LineIntegrityTimer: 10 T392PollingVerificationTimer: 15 N391FullStatusPollingCounter: 6 N392ErrorThreshold: 3 N393MonitoredEventCount: 4 EnhancedLmi: Off PortState: Active PortSignallingState: No Signalling Failure CLLMEnableStatus: Disable CLLMxmtStatusTimer:

25 Chapter 2 General FRSM and MPSM Provisioning Procedures porttype: framerelay PortIngrPercentUtil: 100 PortEgrPercentUtil: 100 PortOversubscribed: False PortSvcStatus: Disable PortSvcInUse: Not In-Use PortSvcShareLcn: Card-based PortSvcLcnLow: 0 PortSvcLcnHigh: 0 PortSvcDlciLow: 0 PortSvcDlciHigh: 0 PortDs0UsedLine1: 0x00ffffff PortDs0UsedLine2: 0x00ffffff PortDs0UsedLine3: PortDs0UsedLine4: PortDs0UsedLine5: PortDs0UsedLine6: PortDs0UsedLine7: PortDs0UsedLine8: PortNumNextAvailable: 3 M8850_SF.1.12.FRSM.a > Step 4 Step 5 To change a frame relay port configuration on a FRSM card, enter the cnfport command in the format shown below: PXM1E_SJ.1.11.VHSHS2B.a> cnfport <portnum> <lmisig> <asyn> <ELMI> <T391> <T392> <N391> <N392> <N393> [lmi_autosense] To change a frame relay port configuration on an MPSM card, enter the cnfport command in the format shown below: M8850_SF.1.28.MPSM8T1.FRM.a > cnfport <portnum> <lmisig> <asyn> <ELMI> <T391> <T392> <N391> <N392> <N393> [lmi_autosense] LMI autosense is supported on MPSM-8T1-FRM and MPSM-8E1-FRM cards in switches running Release 5.1 or higher. Table 2-9 lists and describes the cnfport command parameters. Table 2-9 Parameters for the cnfport Command Parameter or Option port Num lmisig Description Specify the number for the port you want to configure. The dspports command lists all configured ports. LMI signaling protocol type. None = N (default) Strata LMI = S Annex A UNI = au Annex D UNI = du Annex A NNI = an Annex D NNI = dn When LMI is configured, the maximum number of connections per port for Strata LMI port is 560 and for Annex A/D UNI/NNI port is

Connecting BPX 8600 Switches Using MGX 8220 IMA Trunks Sample Configuration

Connecting BPX 8600 Switches Using MGX 8220 IMA Trunks Sample Configuration Connecting BPX 8600 Switches Using MGX 8220 IMA Trunks Sample Configuration Document ID: 20778 Contents Introduction Prerequisites Requirements Components Used Conventions Versions Configure Network Diagram

More information

Preparing SRM Cards for Communications

Preparing SRM Cards for Communications CHAPTER 5 To prepare SRM cards for communication, you need to know which SRM features will be used. Because SRM cards operate as extensions of the PXM cards, they are initialized when you initialize the

More information

Tandem Switch Application (VoIP Mode)

Tandem Switch Application (VoIP Mode) CHAPTER 4 This chapter provides a general description of an application in which a VISM equipped Cisco MGX 8850 and a Cisco VSC 3000 Virtual Switch Controller (Call Agent) combine to provide the functions

More information

Circuit Emulation over IP

Circuit Emulation over IP (CEoIP) provides a virtual circuit through an IP network--similar to a leased line--to integrate solutions that require a time-sensitive, bit-transparent transport into IP networks. Data, with proprietary

More information

Introducing the MGX 8230

Introducing the MGX 8230 CHAPTER 1 Introducing the MGX 8230 This chapter contains an introduction to the Cisco MGX 8230 Edge Concentrator including a summary of product features and equipment. This chapter contains the following

More information

Introducing Frame Relay

Introducing Frame Relay Frame Relay CCNA 4 Note Much of the information in this presentation comes from the CCNP 2 version 3.0 module on Frame Relay. I find a lot of the information in CCNA 4 module 5 Frame Relay not very well

More information

atm txbuff atm txbuff number no atm txbuff Syntax Description

atm txbuff atm txbuff number no atm txbuff Syntax Description atm txbuff atm txbuff To set the maximum number of transmit buffers for simultaneous packet fragmentation, use the atm txbuff interface configuration command. To restore the default value, use the no form

More information

Configuring an Integrated CSU/DSU WAN Interface

Configuring an Integrated CSU/DSU WAN Interface Configuring an Integrated CSU/DSU WAN Interface Version: 2580 Copyright 2007-2010 ImageStream Internet Solutions, Inc., All rights Reserved. Table of Contents Router Installation and Configuration Manual/Configuring

More information

MPLS AToM Overview. Documentation Specifics. Feature Overview

MPLS AToM Overview. Documentation Specifics. Feature Overview MPLS AToM Overview This document provides an introduction to MPLS AToM and includes the following sections: Documentation Specifics, page 14 Feature Overview, page 14 Benefits, page 26 What To Do Next,

More information

PPP. Point-to-Point Protocol

PPP. Point-to-Point Protocol PPP Point-to-Point Protocol 1 Introduction One of the most common types of WAN connection is the point-to-point connection. Point-to-point connections are used to connect LANs to service provider WANs,

More information

Configuring the MGX 8230

Configuring the MGX 8230 CHAPTER 3 Configuring the MGX 8230 The MGX 8230 is a 12-slot card cage that uses a subset of MGX 8850/8250 modules and is configured as an MGX or BPX feeder. This chapter describes the configuration of

More information

Frame Relay Switching Enhancements

Frame Relay Switching Enhancements Frame Relay Switching Enhancements This feature module describes the Frame Relay Switching Enhancements feature. It includes information on the benefits of this new feature, supported platforms, related

More information

4xT1/E1 i nline probe ASE With LinkSafe capabilities

4xT1/E1 i nline probe ASE With LinkSafe capabilities Visual UpTime Select ASE model 807-0115 4xT1/E1 i nline probe ASE With LinkSafe capabilities Key features Four management ports MLPPP support on IP Transport software Inband management capability LinkSafe

More information

NetVanta Series (with E1/FE1 or E1/FE1 with G.703 Drop Network Interface Module)

NetVanta Series (with E1/FE1 or E1/FE1 with G.703 Drop Network Interface Module) VPN WAN LAN PWR STAT TD RD TD RD TD RD VPN WAN LAN PWR STAT TD RD TD RD TD RD NetVanta 3200 NetVanta 3200 NetVanta Series (with E1/FE1 or E1/FE1 with G.703 Drop Network Interface Module) Quick Configuration

More information

Implementing Enterprise WAN Links

Implementing Enterprise WAN Links Implementing Enterprise WAN Links Introducing Routing and Switching in the Enterprise Chapter 7 Version 4.0 1 Objectives Describe the features and benefits of common WAN connectivity options. Compare and

More information

The BANDIT can also concentrate and switch multiple sources of Frame Relay traffic simultaneously.

The BANDIT can also concentrate and switch multiple sources of Frame Relay traffic simultaneously. encor! enetworks TM Version A, March 2008 2013 Encore Networks, Inc. All rights reserved. Routing with Frame Relay This chapter discusses Frame Relay routing. 4.1 Frame Relay You can configure use of synchronous

More information

Equipment and Resource Provisioning

Equipment and Resource Provisioning CHAPTER 3 This chapter describes the commands that let you activate, configure, display, and delete resources at various levels of the switch. These levels are: Node Card Line Port The MGX 8850 node uses

More information

Configuring Circuit Emulation Services

Configuring Circuit Emulation Services CHAPTER 18 Configuring Circuit Emulation Services This chapter describes circuit emulation services (CES) and how to configure the CES T1/E1 port adapters in the Catalyst 8540 MSR, Catalyst 8510 MSR, and

More information

Cisco - An Introduction to Circuit Emulation Services

Cisco - An Introduction to Circuit Emulation Services Page 1 of 14 An Introduction to Circuit Emulation Services Contents Introduction Before You Begin Conventions Prerequisites Components Used CES Concepts Types of Signaling Frame and Cell Processing Types

More information

Fragmenting and Interleaving Real-Time and Nonreal-Time Packets

Fragmenting and Interleaving Real-Time and Nonreal-Time Packets CHAPTER 16 Fragmenting and Interleaving Real-Time and Nonreal-Time Packets Integrating delay-sensitive real-time traffic with nonreal-time data packets on low-speed links can cause the real-time packets

More information

frame-relay lmi-n391dte

frame-relay lmi-n391dte frame-relay lmi-n391dte frame-relay lmi-n391dte To set a full status polling interval, use the frame-relay lmi-n391dte interface configuration command. To restore the default interval value, assuming that

More information

Configuring the 2-Port and 4-Port Clear Channel T3/E3 SPAs

Configuring the 2-Port and 4-Port Clear Channel T3/E3 SPAs 20 CHAPTER Configuring the 2-Port and 4-Port Clear Channel T3/E3 SPAs This chapter provides information about configuring the 2-Port and 4-Port Clear Channel T3/E3 Shared Port Adapters (SPAs) on the Catalyst

More information

ATM Software Segmentation and Reassembly

ATM Software Segmentation and Reassembly Feature History Release Modification 12.2(2)XB Cisco 2600 Series T1/E1 ATM and Cisco 3660 T1 Inverse Multiplexing over ATM (IMA) ATM Adaption Layer 2 (AAL2) Support was introduced. 12.2(8)T This feature

More information

Embedded Management Functions. Signal backhaul xgcp (CAS), Q.931 (PRI) * Call setup/ teardown xgcp * Connection Handling *

Embedded Management Functions. Signal backhaul xgcp (CAS), Q.931 (PRI) * Call setup/ teardown xgcp * Connection Handling * CHAPTER 5 This chapter describes VISM operation. Figure 5-1 shows the functional blocks of VISM. Items marked with a single asterisk apply to VoIP switching and switched AAL2 PVC modes only. Items marked

More information

Configuring the E1 + G.703 and T1 + DSX-1 Modules

Configuring the E1 + G.703 and T1 + DSX-1 Modules 9 Configuring the E1 + G.703 and T1 + DSX-1 Modules Contents Using an E1- or T1-Carrier Line for Data and Voice................... 9-3 Drop-and-Insert Modules..................................... 9-3 Standards

More information

Configuring the Cisco 3825 Mobile Wireless Edge Router in a RAN-O Solution with the Command-Line Interface

Configuring the Cisco 3825 Mobile Wireless Edge Router in a RAN-O Solution with the Command-Line Interface CHAPTER 4 Configuring the Cisco 3825 Mobile Wireless Edge Router in a RAN-O Solution with the Command-Line Interface This chapter describes how to use the Cisco IOS software CLI to configure the Cisco

More information

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES Multiservice Access Concentrators/ ATM Network Termination Units FEATURES Multiservice/ATM network demarcation device or access concentrator (ACE-2002), cellular access concentrator () Offer converged

More information

Chapter 12 Frame Relay

Chapter 12 Frame Relay 1 Chapter 12 Frame Relay Contents Frame Relay Stand. & Eq. Virtual Circuits LMI Performance Parameters Frame Format Frame Relay Topologies Frame Relay Config. Monitoring Frame Relay Review Questions 2

More information

PPP over Frame Relay

PPP over Frame Relay The feature allows a router to establish end-to-end Point-to-Point Protocol (PPP) sessions over Frame Relay. Finding Feature Information, page 1 Prerequisites for, page 1 Restrictions for, page 2 Information

More information

frame-relay lapf n201

frame-relay lapf n201 frame-relay lapf n201 frame-relay lapf n201 To set the Link Access Procedure for Frame Relay (LAPF) N201 value (the maximum length of the Information field of the LAPF I frame), use the frame-relay lapf

More information

Configuring Layer 2 Local Switching

Configuring Layer 2 Local Switching CHAPTER 17 The Layer 2 Local Switching feature allows you to switch Layer 2 data between two physical or virtual interfaces of the same type on the same router. The interfaces can be on the same line card

More information

Chapter 2. Hardware Description. 2.1 Chassis. Note: For product specifications, see Appendix A, Specifications.

Chapter 2. Hardware Description. 2.1 Chassis. Note: For product specifications, see Appendix A, Specifications. Chapter 2 Hardware Description This chapter provides information on the hardware for the BANDIT product family. Note: For product specifications, see Appendix A, Specifications. 2.1 Chassis The chassis

More information

Overview. Port Adapter Overview CHAPTER

Overview. Port Adapter Overview CHAPTER CHAPTER This chapter describes the Cisco PA-T/E-EC port adapter and contains the following sections: Port Adapter, page - T Port Specifications, page - E Cable Specifications, page - Unchannelized Interoperabity

More information

Command Reference. Version: Copyright ImageStream Internet Solutions, Inc., All rights Reserved.

Command Reference. Version: Copyright ImageStream Internet Solutions, Inc., All rights Reserved. Version: 2082 Copyright 2007-2010 ImageStream Internet Solutions, Inc., All rights Reserved. Table of Contents Command Reference...1 A...1 abr {pcr} {mcr}...1 B...1 bandwidth {bits_per_second}...1 baud

More information

Configuring Frame Relay-ATM Interworking

Configuring Frame Relay-ATM Interworking Configuring -ATM Interworking The -ATM Interworking features enable and ATM networks to exchange data, despite differing network protocols. There are two types of -ATM Interworking: FRF.5 -ATM Network

More information

Configuring Synchronized Clocking

Configuring Synchronized Clocking Configuring Synchronized Clocking This appendix describes how to configure synchronized clocking. It contains the following sections: Synchronized Clocking Overview, page 791 Synchronized Clocking Configuration

More information

Using Serial Ports to Connect to ATM with DXI Encapsulation

Using Serial Ports to Connect to ATM with DXI Encapsulation Using Serial Ports to Connect to ATM with DXI Encapsulation Document ID: 10418 Contents Introduction Prerequisites Requirements Components Used Conventions Physical Setup ATM DXI Modes ATM DXI Headers

More information

Configuring the SS7 Port Adapter

Configuring the SS7 Port Adapter CHAPTER 4 To continue your SS7 Port Adapter installation, you must configure the card type as either T1 or E1 and then configure the interfaces. This chapter contains the following sections: Using the

More information

Cisco Enterprise MIB Objects

Cisco Enterprise MIB Objects CHAPTER 3 This chapter describes the common MIB objects used for Cisco enterprise that are used for AXSM, AXSME, PXM1E, PXM45, SRM, SRM-E, FRSM12, RPM-XF, and RPM-PRR. Contents of this chapter include:

More information

Using the setup Command Facility

Using the setup Command Facility CHAPTER 2 This chapter describes how to use the setup command facility to configure your Cisco integrated access device (IAD). The setup command facility prompts you to enter information needed to start

More information

Frame Relay. Frame Relay Information 1 of 18

Frame Relay. Frame Relay Information 1 of 18 Frame Relay Information 1 of 18 This document was retrieved from the Web and has been been edited by Thomas Jerry Scott for use in his TCP/IP network classes. Chapter Goals Describe the history of Frame

More information

Configuring Frame Relay

Configuring Frame Relay This module describes the optional configurable Frame Relay parameters available on Packet-over-SONET/SDH (POS), multilink, and serial interfaces configured with Frame Relay encapsulation. Feature History

More information

Advanced WAN Concepts and Troubleshooting

Advanced WAN Concepts and Troubleshooting 1 Advanced WAN Concepts and Troubleshooting Session 2 Presentation_ID.scr 1 Agenda Overview of WAN Issues Network Interfaces Routed WAN Router Tools and Concepts Network Interfaces Switched WAN Switch

More information

QoS: Time-Based Thresholds for WRED and Queue Limit

QoS: Time-Based Thresholds for WRED and Queue Limit QoS: Time-Based Thresholds for WRED and Queue Limit The QoS: Time-Based Thresholds for WRED and Queue Limit feature allows you to specify the Weighted Random Early Detection (WRED) minimum and maximum

More information

POS on ONS Ethernet Cards

POS on ONS Ethernet Cards 20 CHAPTER This chapter describes packet-over-sonet/sdh (POS) and its implementation on ONS Ethernet cards. This chapter contains the following major sections: POS Overview, page 20-1 POS Interoperability,

More information

Lecture (08) Fundamentals of WANs (II)

Lecture (08) Fundamentals of WANs (II) Agenda Lecture (08) Fundamentals of WANs (II) OSI Layer 2 of WANs ATM & SONET WAN Dr. Ahmed M. ElShafee ١ ٢ OSI Layer 2 of WANs OSI Layer 2 of WANs (2) WAN protocols used on point to point serial links

More information

Introduction to ATM Traffic Management on the Cisco 7200 Series Routers

Introduction to ATM Traffic Management on the Cisco 7200 Series Routers CHAPTER 1 Introduction to ATM Traffic Management on the Cisco 7200 Series Routers In the latest generation of IP networks, with the growing implementation of Voice over IP (VoIP) and multimedia applications,

More information

Distributing Bandwidth Between Queues

Distributing Bandwidth Between Queues CHAPTER 5 Developing a queuing strategy is an important step in optimizing network functionality and services. Equally important is ensuring that bandwidth is shared fairly among the competing traffic

More information

NetVanta Series (with Octal T1 Wide Module)

NetVanta Series (with Octal T1 Wide Module) NetVanta Series (with Octal T1 Wide Module) Quick Configuration Guide 61200890L1-42A July 2004 Tools Required A VT100 terminal or a PC with VT100 emulator software for connecting to the unit DB-9 (male)

More information

Configuring Clear Channel T3/E3 and Channelized T3 and T1/E1 Controllers on the Cisco ASR 9000 Series Router

Configuring Clear Channel T3/E3 and Channelized T3 and T1/E1 Controllers on the Cisco ASR 9000 Series Router Configuring Clear Channel T3/E3 and Channelized T3 and T1/E1 Controllers on the Cisco ASR 9000 Series Router This module describes the configuration of clear channel T3/E3 controllers and channelized T3

More information

CCNA 4 - Final Exam (A)

CCNA 4 - Final Exam (A) CCNA 4 - Final Exam (A) 1. A network administrator is asked to design a system to allow simultaneous access to the Internet for 250 users. The ISP for this network can only supply five public IPs. What

More information

channel-group through cut-through

channel-group through cut-through channel-group, page 2 channel-group (interface), page 7 clear counters, page 13 clear lacp counters, page 17 cut-through, page 18 1 channel-group channel-group To configure serial WAN on a T1 or E1 interface,

More information

Defining QoS for Multiple Policy Levels

Defining QoS for Multiple Policy Levels CHAPTER 13 In releases prior to Cisco IOS Release 12.0(22)S, you can specify QoS behavior at only one level. For example, to shape two outbound queues of an interface, you must configure each queue separately,

More information

Overview. Port Adapter Overview CHAPTER

Overview. Port Adapter Overview CHAPTER CHAPTER This chapter describes the PA-MC-E/ and PA-MC-8E/ port adapters and contains the following sections: Port Adapter, page - Features, page -4 Compliance and Electrical Interface Specifications for

More information

Configuring the Cisco IPICS RMS Component

Configuring the Cisco IPICS RMS Component Configuring the Cisco IPICS RMS Component APPENDIXA This appendix describes the configuration steps that you must follow to configure the RMS router for use with the Cisco IPICS server. The Cisco IPICS

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

This chapter deals with CSM LIM Configuration:

This chapter deals with CSM LIM Configuration: CHAPTER 14 This chapter deals with LIM Configuration: General, page 14-1 Circuit Emulation Service (CES), page 14-2 7810 Application, page 14-3 Line Configuration, page 14-4 Maintenance, page 14-12 CES

More information

Configuring Frame Relay-ATM Interworking

Configuring Frame Relay-ATM Interworking The Frame Relay-ATM Interworking features enable Frame Relay and ATM networks to exchange data, despite differing network protocols. There are two types of Frame Relay-ATM Interworking: FRF.5 Frame Relay-ATM

More information

NetVanta Series (with 56K/64K Network Interface Module)

NetVanta Series (with 56K/64K Network Interface Module) VPN WAN LAN PWR STAT TD RD TD RD TD RD VPN WAN LAN PWR STAT TD RD TD RD TD RD NetVanta 3200 NetVanta 3200 NetVanta Series (with 56K/64K Network Interface Module) Quick Configuration Guide 64200861L1-42A

More information

ATM. Asynchronous Transfer Mode. (and some SDH) (Synchronous Digital Hierarchy)

ATM. Asynchronous Transfer Mode. (and some SDH) (Synchronous Digital Hierarchy) ATM Asynchronous Transfer Mode (and some SDH) (Synchronous Digital Hierarchy) Why use ATM? Circuit switched connections: After initial setup no processing in network nodes Fixed bit rates, fixed time delay

More information

Multilink Frame Relay (FRF.16)

Multilink Frame Relay (FRF.16) Multilink Frame Relay (FRF.16) The Multilink Frame Relay feature introduces functionality based on the Frame Relay Forum Multilink Frame Relay UNI/NNI Implementation Agreement (FRF.16). This feature provides

More information

Modular QoS CLI Three-Level Hierarchical Policer

Modular QoS CLI Three-Level Hierarchical Policer Modular QoS CLI Three-Level Hierarchical Policer The Modular QoS CLI (MQC) Three-Level Hierarchical Policer extends the traffic policing functionality by allowing you to configure traffic policing at three

More information

Configuring Cisco Integrated Data Service Unit/Channel Service Unit (DSU/CSU) Modules and WAN Interface Cards

Configuring Cisco Integrated Data Service Unit/Channel Service Unit (DSU/CSU) Modules and WAN Interface Cards Configuring Cisco Integrated Data Service Unit/Channel Service Unit (DSU/CSU) Modules and WAN Interface Cards Document ID: 10265 Interactive: This document offers customized analysis of your Cisco device.

More information

Packet Classification Using the Frame Relay DLCI Number

Packet Classification Using the Frame Relay DLCI Number Packet Classification Using the Frame Relay DLCI Number The Packet Classification Using the Frame Relay DLCI Number feature allows customers to match and classify traffic on the basis of one or more Frame

More information

clock rate through cut-through

clock rate through cut-through clock rate through cut-through clock rate, page 3 clock rate (interface ATM), page 6 clock rate (interface serial), page 10 clock rate network-clock, page 14 clock recovered adaptive/differential cem,

More information

CPEG 514. Lecture 11 Asynchronous Transfer Mode (ATM) CPEG 514

CPEG 514. Lecture 11 Asynchronous Transfer Mode (ATM) CPEG 514 Lecture 11 Asynchronous Transfer Mode () Outline Introduction Virtual Circuit Setup PVC vs. SVC Quality of Service and Congestion Control IP over and Frame Relay interworking Network (integrated voice,

More information

WAN technology which are to be discussed:

WAN technology which are to be discussed: WAN Technology Operates at 3 layer OSI model as below: 1. PHY 2. Data Link 3. Network Most of WAN technology are packetswitched network categorized as Switched Virtual circuit Network ( 3-phase, connection

More information

AXSM Command Reference

AXSM Command Reference CHAPTER 3 This chapter provides descriptions of the commands that are available on the AXSM CLI. The commands are in alphabetical order. The descriptions include the following information about the commands:

More information

Configuring RTP Header Compression

Configuring RTP Header Compression Configuring RTP Header Compression First Published: January 30, 2006 Last Updated: July 23, 2010 Header compression is a mechanism that compresses the IP header in a packet before the packet is transmitted.

More information

Layer 2 Local Switching

Layer 2 Local Switching Layer 2 Local Switching First Published: December 17, 2003 Last Updated: November 24, 2010 The Layer 2 Local Switching feature allows you to switch Layer 2 data in two ways: Between two interfaces on the

More information

POS on ONS Ethernet Cards

POS on ONS Ethernet Cards CHAPTER 23 This chapter describes packet-over-sonet/sdh (POS) and its implementation on ONS Ethernet cards. This chapter contains the following major sections: POS Overview, page 23-1 POS Interoperability,

More information

Understanding the Variable Bit Rate Real Time (VBR rt) Service Category for ATM VCs

Understanding the Variable Bit Rate Real Time (VBR rt) Service Category for ATM VCs Understanding the Variable Bit Rate Real Time (VBR rt) Service Category for ATM VCs Document ID: 10414 Contents Introduction Prerequisites Requirements Components Used Conventions What is Variable Bit

More information

Configuring RTP Header Compression

Configuring RTP Header Compression Header compression is a mechanism that compresses the IP header in a packet before the packet is transmitted. Header compression reduces network overhead and speeds up the transmission of either Real-Time

More information

AMX-1344 Access DCS-MUX

AMX-1344 Access DCS-MUX AMX-1344 Access DCS-MUX Description Features : Support DACS (Digital Access Cross-connect System) with full cross-connect Support full DS0 cross-connect, backplane capacity up to 128 Mbps Single controller,

More information

QoS: Per-Session Shaping and Queuing on LNS

QoS: Per-Session Shaping and Queuing on LNS QoS: Per-Session Shaping and Queuing on LNS First Published: February 28, 2006 The QoS: Per-Session Shaping and Queuing on LNS feature provides the ability to shape (for example, transmit or drop) or queue

More information

This document is not restricted to specific software or hardware versions.

This document is not restricted to specific software or hardware versions. Frame Relay Glossary Document ID: 47202 Contents Introduction Prerequisites Requirements Components Used Conventions Glossary Related Information Introduction This document defines common Frame Relay terms.

More information

voice-enabling.book Page 72 Friday, August 23, :19 AM

voice-enabling.book Page 72 Friday, August 23, :19 AM voice-enabling.book Page 72 Friday, August 23, 2002 11:19 AM voice-enabling.book Page 73 Friday, August 23, 2002 11:19 AM C H A P T E R 4 Offering Bundled and Data Services Chapter 2, VoIP Network Architectures:

More information

Teldat Router. Frame Relay

Teldat Router. Frame Relay Teldat Router Frame Relay Doc. DM503-I Rev. 8.40 September, 2000 INDEX Chapter 1 The Frame Relay interface... 1 1. Introduction...2 2. Frame Relay Overview...3 2.1. Frame Relay Network...3 2.2. Frame Relay

More information

Traffic Management. Traffic Management Functions CHAPTER

Traffic Management. Traffic Management Functions CHAPTER CHAPTER 7 MGX 8250 traffic management features are designed to minimize congestion while maximizing the efficiency of traffic routing. Parameters such as minimum cell rate (MCR), committed information

More information

Part II. Chapter 6. Frame Relay

Part II. Chapter 6. Frame Relay Part II Chapter 6 is one of the most popular methods used to connect WAN links because of its speed, reliability, and cost. is a packet-switched technology. Packet-switched networks allow end devices to

More information

QoS: Match on ATM CLP

QoS: Match on ATM CLP QoS: Match on ATM CLP First Published: May 7, 2004 Last Updated: February 28, 2006 The QoS: Match on ATM CLP feature allows you to match and classify packets arriving at an interface on the basis of the

More information

Multi-Service Interworking Frame Relay and ATM Service Interworking over MPLS. MFA Forum

Multi-Service Interworking Frame Relay and ATM Service Interworking over MPLS. MFA Forum Multi-Service Interworking Frame Relay and Service Interworking over MFA Forum 15.0.0 MFA Forum Technical Committee January 2007 and Service Interworking over MFA Forum 15.0.0 Note: The user s attention

More information

Frame Relay over L2TPv3

Frame Relay over L2TPv3 The (FRoL2TPv3) feature enables Frame Relay switching over Layer 2 Tunnel Protocol Version 3 (L2TPv3). The feature works with like interfaces and disparate interfaces (L2VPN interworking). Finding Feature

More information

Classifying Network Traffic

Classifying Network Traffic Classifying Network Traffic Last Updated: December 2, 2011 Classifying network traffic allows you to organize traffic (that is, packets) into traffic classes or categories on the basis of whether the traffic

More information

Classifying Network Traffic

Classifying Network Traffic Classifying Network Traffic Last Updated: December 8, 2011 Classifying network traffic allows you to organize traffic (that is, packets) into traffic classes or categories on the basis of whether the traffic

More information

Technical Committee. Circuit Emulation Service Interoperability Specification Version 2.0. af-vtoa

Technical Committee. Circuit Emulation Service Interoperability Specification Version 2.0. af-vtoa Technical Committee Circuit Emulation Service Interoperability Specification Version 2.0 af-vtoa-0078.000 January 1997 af-vtoa-0078.000 CES-IS V2.0 Circuit Emulation Service Interoperability Specification

More information

Quick Start Guide L1-13B June Network Diagram. Tools Required. Installing and Configuring the NetVanta 950 IAD

Quick Start Guide L1-13B June Network Diagram. Tools Required. Installing and Configuring the NetVanta 950 IAD Installing and Configuring the NetVanta 950 IAD (with Octal FXS/FXO, Octal Ethernet, and T1/V.35 modules) Quick Start Guide 64200788L1-13B June 2004 Tools Required A VT100 terminal or a PC with VT100 emulator

More information

CCNA 4 - Final Exam Answers

CCNA 4 - Final Exam Answers CCNA 4 - Final Exam Answers 1 Which of the following describes the roles of devices in a WAN? (Choose three.) *** A CSU/DSU terminates a digital local loop. A modem terminates a digital local loop. A CSU/DSU

More information

Overview encapsulation hdlc show interface show controllers show interface debug PPP

Overview encapsulation hdlc show interface show controllers show interface debug PPP PPP CCNA 4 Overview Explain serial communication Describe and give an example of TDM Identify the demarcation point in a WAN Describe the functions of the DTE and DCE Discuss the development of HDLC encapsulation

More information

AIM-ATM, AIM-VOICE-30, and AIM-ATM-VOICE-30 on the Cisco 2600 Series and Cisco 3660

AIM-ATM, AIM-VOICE-30, and AIM-ATM-VOICE-30 on the Cisco 2600 Series and Cisco 3660 AIM-ATM, AIM-VOICE-30, and AIM-ATM-VOICE-30 on the Cisco 2600 Series and Cisco 3660 Feature History Release 12.2(2)XA 12.2(2)XB Modification The High-Performance ATM Advanced Integration Module (AIM-ATM)

More information

Frame Relay Queueing and Fragmentation at the Interface

Frame Relay Queueing and Fragmentation at the Interface Frame Relay Queueing and Fragmentation at the Interface Last Updated: October 6, 2011 The Frame Relay Queueing and Fragmentation at the Interface feature introduces support for low-latency queueing (LLQ)

More information

Overview. Port Adapter Overview CHAPTER

Overview. Port Adapter Overview CHAPTER CHAPTER This chapter describes the PA-A-IMA port adapter and contains the following sections: Port Adapter, page - Inverse Multiplexing over ATM, page - Features, page - LEDs, page - Cables, Connectors,

More information

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet Data Sheet Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet These flexible interface cards support multiple integrated data and voice applications,

More information

CHANNELIZED DS-1/E1, DS-3, and OC-3/STM-1 CEM NETWORK MODULES

CHANNELIZED DS-1/E1, DS-3, and OC-3/STM-1 CEM NETWORK MODULES CHANNELIZED /E1, DS-3, and OC-3/STM-1 CEM NETWORK MODULES Circuit Emulation Interfaces for ASX, TNX, BXR 400, and BXR1600 Multiservice Switches Asynchronous Transfer Mode (ATM) networks have long been

More information

Broadband Access Solutions

Broadband Access Solutions Broadband Access Solutions 1 Customer Premises Equipment Telindus 1421 Router Telindus 1431 Router Telindus Central Office Equipment Telindus 2400 series Telindus Access Routers Telindus 1030 series 2

More information

Cisco MGX 8830/B ATM Multiservice Switch

Cisco MGX 8830/B ATM Multiservice Switch Cisco MGX 8830/B Advanced ATM Multiservice Switch The Cisco MGX 8830/B Advanced ATM Multiservice Switch is a small form factor solution for data and voice networks. It supports a full suite of ATM/FR Layer

More information

Teldat Router. Configuration of Frame Relay Interfaces over ISDN

Teldat Router. Configuration of Frame Relay Interfaces over ISDN Teldat Router Configuration of Frame Relay Interfaces over ISDN Doc. DM523-I Rev. 8.30 February, 2000 INDEX Chapter 1 Frame Relay Interface over ISDN... 1 1. Introduction...2 2. ISDN base Interface...3

More information

Overview. Port Adapter Overview. Channelized T1/E1 Overview CHAPTER

Overview. Port Adapter Overview. Channelized T1/E1 Overview CHAPTER CHAPTER This chapter describes the PA-MC-8TE+ port adapter and contains the following sections: Port Adapter, page - Channelized T/E, page - Features, page - LEDs, page - Cables, Connectors, and Pinouts,

More information

Overview of Circuit Emulation

Overview of Circuit Emulation Circuit Emulation (CEM) is a technology that provides a protocol-independent transport over IP/MPLS networks. It s proprietary or legacy applications to be carried transparently to the destination, similar

More information

Configuring Frame Relay

Configuring Frame Relay Configuring Frame Relay Last Updated: October 6, 2011 Feature History Release Cisco IOS Modification For information about feature support in Cisco IOS software, use Cisco Feature Navigator. Finding Feature

More information