Managed Switch Console Manual

Size: px
Start display at page:

Download "Managed Switch Console Manual"

Transcription

1 TM Managed Switch Console Manual Industrial Managed Ethernet Switch Version 1.1 This document applied to models of MSM-508,MSM-508FC/FCS/FT Copyright ICP DAS Co., Ltd., All Rights Reserved. Release No. : 0804-V1

2 CONTENTS 1 CONTENTS 2 2 Managed Switch 1 3 RS-232 & Telnet Console Operation 1 1. Console Connection Console Command... 4? [COMMAND] 4 REBOOT/RESET 4 DEFAULT 5 IP 5 MASK 6 GATEWAY 6 MAC 6 NETID [id number] 7 LMASK [mask value] 8 CMASK [mask value] 9 SMASK [mask value] 9 LVALUE 10 CMASK 10 SMASK 11 HMIVALUE [value1] [value2] 11 RTIME [time] 12 FTIME [time] 13 MTIME [time] 13 HTIME [time] 14 COM1 [baud rate][data bit][parity][stop bit] 15 COM2 [baud rate][data bit][parity][stop bit] 16 RING [pair][enable disable] 16 Release No. : 0804-V1

3 Managed Switch RS-232 & Telnet Console Operation Console Connection Console Command ICPDAS Managed Switch provides three access methods, RS-232, Telnet and HTTP, to configure the Switch functions. This Manual will guide you how to use the RS-232 and Telnet to access Managed Switch console. Release No. : 0804-V1 1

4 1. Console Connection RS-232 Connection ICPDAS RS Series Switch is shipped with a 9-pin Female D-sub & RJ-45 cable (CA ),please use this cable to connect Switch s RS232 port with PC s COM port. You can connect to Switch console by using windows Terminal Emulator, Baud Rate : Data Bits : 8 Parity : none Stop Bit : 1 Otherwise, you can download our free Console Emulator from RS Series Switch download page: Telnet Connection Before using telnet to access console, please mask sure the PC host and Managed Switch are on the same subnet. Factory default: IP Address : Gateway : Mask : Otherwise, you have to change the network setting through the RS-232 connection. STEP 1 Click windows [Start] [Run] Type the Telnet command and switch s IP address. EX: telnet STEP 2 If connection succeeds, the login prompt will appear. Release No. : 0804-V1 2

5 By factory default setting, both the account and password are Admin. Only one telnet connection is accepted at the same time. Release No. : 0804-V1 3

6 2. Console Command? [COMMAND] Both help and? display a list of available commands, if parameter is not specified. The [command] parameter is used to see detail information for a specific command Parameter command Please provide the name of the command that you want detail information about. REBOOT/RESET The reset command will initiate Ring Switch a self-restart. All current setting values remain intact. Release No. : 0804-V1 4

7 DEFAULT The default command will restore all settings to factory default values. Current factory default values are as follow: COM1:baudrate ,8bit,none patity check, 1 stopbit COM2:baudrate ,8bit,none patity check, 1 stopbit link mask:0 communication mask:0x1f status mask:0x3 netid:1 mac: factory-set unique MAC address ip: mask: IP If no IP address is specified, the ip command will display current IP address. To assign an IP address for TCP/IP, please input IP address in the form of ip1.ip2.ip3.ip4 (each field contains a value in the range 0 255). Release No. : 0804-V1 5

8 MASK If no mask address is specified, the mask command will display current mask address. To assign a mask address for TCP/IP, please input mask address in the form of m1.m2.m3.m4 (each field contains a value in the range 0 255). GATEWAY If no gateway IP address is specified, the gateway command will display current gateway address. Note that if there exits a check sum error, an error message will alert. To assign a gateway address for TCP/IP, please input gateway IP address in the form of ip1.ip2.ip3.ip4 (each field contains a value in the range 0 255). MAC If no MAC address is specified, the mac command will display current MAC address. To assign a MAC address for Ethernet, please input MAC address in the form of e1:e2:e3:e4:e5:e6. Release No. : 0804-V1 6

9 Each Switch is shipped from the factory with a unique MAC address, and the value is labeled on the Switch case. DO NOT change this address unless you have a good reason to do so. NETID [id number] If Net ID of Modbus is not specified, the netid command will display current ID number of Modbus. The command parameter [id number] is used to assign a specific ID number for Modbus Net ID. Parameter id number Provides the ID number that you want to set up for Modbus Net ID. Release No. : 0804-V1 7

10 LMASK [mask value] This command enables you to configure relay output activation status when there is link loss occurring on port(s). The ports are corresponding to the 8 mask bits, bit 0 corresponds to port 1, etc. TABLE 1: Bits mapping Table Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Port 8 Port 7 Port 6 Port 5 Port 4 Port 3 Port 2 Port 1 1 on 1 on 1 on 1 on 1 on 1 on 1 on 1 on 0 off 0 off 0 off 0 off 0 off 0 off 0 off 0 off If the mask bit of that port(s) is specified by being set up as 1, when there is a link loss occurring on that port(s), relay output will be activated. The mask value is in hexadecimal format that represents the 8 bits corresponding binary numbers, it can be either in the form of initiating 0X plus a suffix of the hexadecimal number or eliminating 0X ; simply the hexadecimal number itself. If a mask value is not specified, the lmask command will display previous assigned mask value. Parameter mask value Provides the mask value that you want to specify to configure status of relay when link loss occurs lmask 0x2d Set Relay active if link lose on Port 1, 3, 4, or Port 6. Release No. : 0804-V1 8

11 CMASK [mask value] This command enables you to configure relay output activation status when there is communication loss occurring on port(s). The ports are corresponding to the 8 mask bits, bit 0 corresponds to port 1, etc. The bits mapping please refer to TABLE 1. (LMASK command) cmask 0x1a Set Relay active if communication lose on Port 2, 4, or port 6. SMASK [mask value] This command enables you to configure relay output activation status when there is power fail occurring on power 1 or power 2, or when the switch is being selected as the master switch. Bit 0 corresponds to Power1, bit 1 corresponds to Power 2 and bit 3 corresponds to master switch indicator. If the mask bit of that power(s)(bit 0 and bit 1) or master switch indicator (bit 2) is specified by being set up as 1, when there is a power fail occurring on Power(s), or when the switch is selected as master switch, the corresponding relay output will be activated. Parameter mask value Provides the mask value that you want to specify for the communication loss relay output smask 0x3 Release No. : 0804-V1 9

12 Set Relay active if Power 1 or Power 2 fail LVALUE This command enables you to read link status showing by a hexadecimal number that represents the 8 bits corresponding binary numbers. Bit 0 corresponds to port 1, etc. If there is link loss occurring on port(s), the corresponding bit(s) will be set up as 1. Link loss occurring on port 2,3,4,5,6 and 8. CMASK This command enables you to read ring pair communication status showing by a hexadecimal number that represents the 8 bits corresponding binary numbers. Bit 0 corresponds to port 1, etc.. If there is a communication loss occurring on port(s), the corresponding bit(s) will be set up as 1. Release No. : 0804-V1 10

13 SMASK This command enables you to read system status showing by a hexadecimal number that represents the 8 bits corresponding binary numbers. bit Corresponding to: 0 Power 1 If there is a power fail occurring on Power 1, bit 0 will be set as 1. 1 Power 2 If there is a power fail occurring on Power 2, bit 1 will be set as 1. 2 Master Ring Switch If his Switch is the master Ring Switch (the Master LED indicator will be on ) bit 2 will be set as 1. 3 Relay output status If the relay output is activated, bit 3 will be set as 1. Power2 fail occurring, and the Switch is the Master of the topology. HMIVALUE [value1] [value2] This command enables you to configure the Switch operation modes. Parameter Value 1 bit0 : set 1 to enable ring pair 1. bit1 : set 1 to enable ring pair 2. bit2 : set 1 to enable STP Protocol. otherwise is Cyber-Ring Protocol bit3 : set 1 to force Switch as the Master of topology. Value 2 Reserved. Release No. : 0804-V1 11

14 RTIME [time] Recovery time is the length of time it takes to return back to normal operation after an error or other failure has occurred. This command enables you to set up the recovery time in millisecond (ms). Parameter time Provides the time interval(ms) that you want to set up as the recovery time Return message: recovery time X (Y) ms. X ( switch value) indicates the rtime value set by console command, Y (operating value) indicates the actual operating value. Value can be specified only on Cyber-Ring Protocol Mode (refer to HMIVLAUE setting). NOTE Use the following function to calculate an adequate rtime: rtime = [Round(0.3*(N+1))]*100 ms N: number of switches : If there are 5 switches (including master switch), the adequate rtime will be: Release No. : 0804-V1 12

15 [Round (0.3*(5+1))]*100 = Round (1.8) *100 =2*100 =200 ms If the recovery time is not longer enough, the Master LED will keep on flashing to make a warning. FTIME [time] This command enables you to set up the spanning tree bridge forward delay in milliseconds (ms). Forward delay is the time interval spent waiting to change a port from its spanning tree pre-forwarding state to a forwarding state. This is necessary because every bridge on the network should ensure no loop is formed before allowing the port to forward packets. Parameter time Provides the time interval(ms) that you want to set up as the forward time Return message: forward delay X (Y) ms. X ( switch value) indicates the ftime value set by console command, Y (operating value) indicates the actual operating value. Value can be specified only on STP Mode (refer to HMIVLAUE setting). MTIME [time] This command enables you to setup the spanning tree bridge maximum age in milliseconds (ms). Max age is the maximum time a bridge waits without receiving spanning tree configuration messages before attempting a reconfiguration. Release No. : 0804-V1 13

16 Parameter time Provides the time interval(ms) that you want to set up as the maximum time Return message: max age time X (Y) ms. X ( switch value) indicates the mtime value set by console command, Y (operating value) indicates the actual operating value. Value can be specified only on STP Mode (refer to HMIVLAUE setting). HTIME [time] This command enables you to set the spanning tree bridge hello time in millisecond (ms). Hello time is the interval between transmissions of spanning tree configuration messages. All bridges send configuration messages during reconfiguration to select the designated root bridge (in this case, the switch port). Parameter time Provides the time interval(ms) that you want to set up as the hello time Return message: hello time X (Y) ms. X (switch value) indicates the htime value set by console command, Y (operating value) indicates the actual operating value. Value can be specified only on STP Mode (refer to HMIVLAUE setting). Release No. : 0804-V1 14

17 COM1 [baud rate][data bit][parity][stop bit] The first serial port Com1 is assigned for RS232. This command enables you to set up the transmission speed (baud rate),data bit (data bit), parity check type (parity) and stop bit (stop bit). The transmission speed parameter [baud rate] allows the following settings: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and The port speed and device speed must match. The number of data bits can be 7 (for true ASCII) or 8 (for any kind of data, as this matches the size of a byte), The parity check code can be set to none (0), even (1), or odd (2). None (0) means that no parity bit is sent at all. Even (1) means applying even parity check, each set of transmitted bits must have an even number of set bits. Odd (2) means applying odd parity check, each set of transmitted bits must have an odd number of set bits. Stop bit is used in asynchronous communications to indicate the end of a piece of data. Parameter baud rate Provides the baud rate (300 or 600 or 1200 or 2400 or 4800 or 9600 or or or or )for your usage, default value is data bit Provides the data bit value(7 or 8), default value is 8 parity Provides the parity check type, none (0), even (1), odd (2):, default value is 0. stop bit Provides the stop bit (1 or 2), default value is 1. Release No. : 0804-V1 15

18 COM2 [baud rate][data bit][parity][stop bit] The second serial port Com2 is assigned for RS485. This command enables you to set up the transmission speed (baud rate),data bit (data bit), parity check type (parity) and stop bit (stop bit). Setting parameters are the same as COM1. RING [pair][enable disable] 1. Display ring setting 2. Enable/Disabled Ring Pair Parameter pair Specify ring pair 1 or 2 enable disable Enable/Disabled Ring Pair. Release No. : 0804-V1 16

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual SWP-0208G 1 SWP-0208G, 8+2SFP 8-Port Gigabit Web Smart Switch User s Manual Version: 3.4 April 1, 2008 2 TABLE OF CONTENT 1.0 INTRODUCTION...4 1.1 MAIN FEATURES...4 1.2 START TO MANAGE THIS SWITCH...6

More information

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter Document Name : User Manual for SC10EJ Serial to Ethernet Converter Page 1 of 10 INDEX 1. Technical Specifications 1 2. Modes of Operation 1 3. Configuring the SC10 EJ : Through Serial Port 2 a. Configuring

More information

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide 28-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-28040 / WGSW-28040P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5

More information

rbox610 Series Robust Din-rail Fanless Embedded System Web Configuration and App Software User s Manual

rbox610 Series Robust Din-rail Fanless Embedded System Web Configuration and App Software User s Manual rbox610 Series Robust Din-rail Fanless Embedded System Web Configuration and App Software User s Manual Disclaimers This manual has been carefully checked and believed to contain accurate information.

More information

D-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax:

D-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax: Product: DFL-500 Internet Firewall Index Setup Introduction...2 Set Up Using Web Configurator...3 Setting Up Internal IP Address using CLI...4 Setting UP External IP Address Manually Using CLI...4 How

More information

VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE

VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE 9033645-01 Notice Only qualified personnel should perform installation procedures. NOTICE Enterasys Networks reserves the right to make

More information

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide 16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS-4210-16T2S/GS-4210-24T2S/GS-4210-48T4S Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3.

More information

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide 16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS-4210-16P2S GS-4210-24P2S Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Terminal

More information

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Technical Specifications 1 Installation Procedure 1 LED Indications 2 Configuration Procedure Configuration

More information

48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP. Managed Switch WGSW Quick Installation Guide

48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP. Managed Switch WGSW Quick Installation Guide 48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP Managed Switch WGSW-5242 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to the Console...

More information

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide 48-Port 10/100/1000Base-T with 4 Shared SFP Managed Gigabit Switch WGSW-48000 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to the Console...

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

GEM80 & ewon Setup Quick Guide

GEM80 & ewon Setup Quick Guide Introduction to the ewon The ewon is an intelligent, programmable Ethernet Gateway, which can be used to bridge GEM 80 PLCs onto an Ethernet network, via the PLC serial port (Port3). This provides network-based

More information

tsh-700 Series User Manual

tsh-700 Series User Manual tsh-700 Series User Manual Tiny Serial Port Sharer Aug. 2017 Ver. 1.6 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery

More information

ezconfig User s Manual

ezconfig User s Manual eztcp Configuration Program ezconfig User s Manual Version 1.2 2009-09-23 Sollae Systems Co., Ltd. http://www.sollae.co.kr Contents Contents... - 1-1 Overview... - 4-1.1 Overview... - 4-1.2 Related Products...

More information

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS Multi-port Coax + 2-port 10/100/1000T + 2-port 100/1000X SFP Long Reach PoE over Coaxial Managed Switch LRP-822CS / LRP-1622CS Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements...

More information

TFC-1600MM Media Conversion System. Management Configuring Guide

TFC-1600MM Media Conversion System. Management Configuring Guide TFC-1600MM Media Conversion System Management Configuring Guide CONFIGURING THE SYSTEM This chapter provides network managers and system administrators with information about how to configure the Media

More information

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS Quick Installation Guide

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS Quick Installation Guide 24-Port Gigabit with 4 Optional 10G Slots Layer 3 Managed Stackable Switch XGS3-24040 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements... 5 4.

More information

STM-1 Mux SONET/SDH Multiplexer User Manual

STM-1 Mux SONET/SDH Multiplexer User Manual STM-1 Mux SONET/SDH Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The

More information

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

GW1000 User s Guide. Revision 1.04 Mar 30, 2008 GW1000 User s Guide Revision 1.04 Mar 30, 2008 Website: www.datalink-networks.com Tel : (604) 632-4278 / (866) 709-6390 Table of Contents 1.0 GW1000 General Operation & Applications... 3 2.0 Hardware Specifications...

More information

SE5416A Series Industrial Serial Device Server User s Manual

SE5416A Series Industrial Serial Device Server User s Manual SE5416A Series Industrial Serial Device Server User s Manual v. 1.1 April, 2017 Important Announcement The information contained in this document is the sole property of Atop Technologies, Inc. and is

More information

24-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch

24-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch 24-Port 10/100/1000Mbps with 4 Shared SFP Managed Gigabit Switch WGSW-24040 / WGSW-24040R SGSW-24040 / SGSW-24040R SGSW-24040P / SGSW-24040P4 SGSW-24240 / SGSW-24240R SGSW-24040HP Quick Installation Guide

More information

L2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series

L2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series L2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series Quick Installation Guide Table of Contents 1. Introduction... 3 2. Package Contents... 4 3. Requirements... 5 4. Terminal Setup... 6 5. Logon

More information

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0. ECAN-240 (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.0 Page: 1 Table of Contents Table of Contents -----------------------------------------------------------------------------2

More information

GEM-10 GPRS/Modbus Gateway User Manual. Rev /2012

GEM-10 GPRS/Modbus Gateway User Manual. Rev /2012 GEM-10 GPRS/Modbus Gateway User Manual Rev 1.04 05/2012 1.Introduction 1.1 General Features ENTES GEM-10 GPRS/Modbus Gateway allows you to connect to your devices which communicate using Modbus protocol

More information

Chapter. Managed Switch. Quick Start. In This Chapter...

Chapter. Managed Switch. Quick Start. In This Chapter... Chapter Managed Switch 2 Quick Start In This Chapter... Connecting to the Switch for the first time...2 2 Connecting to the switch over Ethernet:... 2 2 Setting up PC for USB connection to switch:... 2

More information

IFS POC2502 Series Quick Start Guide

IFS POC2502 Series Quick Start Guide IFS POC2502 Series Quick Start Guide RS-232 to RJ45 Console Cable x 1 Content Package Contents 1 Requirements 1 Terminal Setup 2 Logon to Console 2 Configuring IP Address 2 Saving the Configuration via

More information

L2+ Managed LCD Switch GS T2XV(R) / GS T4XV(R) Quick Installation Guide

L2+ Managed LCD Switch GS T2XV(R) / GS T4XV(R) Quick Installation Guide L2+ Managed LCD Switch GS-5220-16T2XV(R) / GS-5220-24T4XV(R) Quick Installation Guide Table of Contents 1 Package Contents... 3 2. Requirements... 4 3. Terminal Setup... 5 3.1 Logon to Console... 6 3.2

More information

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide Industrial 24-Port 10/100/1000Mbps Managed Gigabit Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4

More information

Configuring Terminal Settings and Sessions

Configuring Terminal Settings and Sessions This chapter contains the following sections: Information About Terminal Settings and Sessions, page 1 Configuring the Console Port, page 3 Configuring the COM1 Port, page 5 Configuring Virtual Terminals,

More information

Managed Ethernet Switch User s Manual

Managed Ethernet Switch User s Manual Managed Ethernet Switch User s Manual Information Coding: UM00D908 Version: V1.1 Product version: all Product Name: Managed Industrial Ethernet Switches on DIN Rail and Rack. Applicable to: Technical Support

More information

Moxa Embedded Switch Module EOM-104 User s Manual.

Moxa Embedded Switch Module EOM-104 User s Manual. Moxa Embedded Switch Module EOM-104 User s Manual www.moxa.com/product First Edition, June 2009 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described

More information

Moxa Embedded Switch Module EOM-104 Series User s Manual

Moxa Embedded Switch Module EOM-104 Series User s Manual Moxa Embedded Switch Module EOM-104 Series User s Manual Edition 4.0, March 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. Moxa Embedded Switch Module EOM-104 Series User s Manual The software

More information

Industrial L2/L4 Managed Gigabit Switch. With 4-Port 802.3at PoE+ IGS P4T/IGS P4T2S. Quick Installation Guide

Industrial L2/L4 Managed Gigabit Switch. With 4-Port 802.3at PoE+ IGS P4T/IGS P4T2S. Quick Installation Guide Industrial L2/L4 Managed Gigabit Switch With 4-Port 802.3at PoE+ IGS-4215-4P4T/IGS-4215-4P4T2S Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring the Power

More information

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide 24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed Metro Ethernet Switch MGSW-28240F Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5

More information

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS / XGS Quick Installation Guide

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS / XGS Quick Installation Guide 24-Port Gigabit with 4 Optional 10G Slots Layer 3 Managed Stackable Switch XGS3-24042 / XGS3-24242 Quick Installation Guide Table of Contents 1. Package Content... 3 2. Switch Management... 4 3. Requirements...

More information

8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT

8-Port 10/100Mbps + 2G TP/SFP Combo. Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT 8-Port 10/100Mbps + 2G TP/SFP Combo Managed Industrial Switch ISW-1022M / ISW-1022MT / ISW-1022MP / ISW-1022MPT / ISW-1033MT Quick Installation Guide Table of Contents 1. Package Content... 3 2. Requirements...

More information

Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature

Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature IGS-10020PT / IGS-10020HPT Quick Installation Guide Version 1.0 Table of Contents 1.

More information

IFS NS P-4S-2X Quick Start Guide

IFS NS P-4S-2X Quick Start Guide IFS NS4802-24P-4S-2X Quick Start Guide SFP Dust-proof Cap x 8 Content Package Contents 1 Requirements 1 Terminal Setup 2 Logon to Console 2 Configuring IP Address 2 Starting Web Management 3 Saving Configuration

More information

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Terminal Setup... 5 4. Logon to Console... 6 5.

More information

L2+ 16-/24-Port Gigabit PoE. + 2-/4-Port 10G SFP+ Managed Switch. with LCD Touch Screen GS P2XV(R)/GS UP2XV(R)

L2+ 16-/24-Port Gigabit PoE. + 2-/4-Port 10G SFP+ Managed Switch. with LCD Touch Screen GS P2XV(R)/GS UP2XV(R) L2+ 16-/24-Port Gigabit PoE + 2-/4-Port 10G SFP+ Managed Switch with LCD Touch Screen GS-5220-16P2XV(R)/GS-5220-16UP2XV(R) GS-5220-24P4XV(R)/GS-5220-24PL4XV(R) GS-5220-24UP4XV(R)/GS-5220-24UPL4XV(R) Quick

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

24-Port Gigabit + 4-Port 10G SFP+ Slot. Layer 3 Stackable Managed Switch XGS Quick Installation Guide

24-Port Gigabit + 4-Port 10G SFP+ Slot. Layer 3 Stackable Managed Switch XGS Quick Installation Guide 24-Port Gigabit + 4-Port 10G SFP+ Slot Layer 3 Stackable Managed Switch XGS3-24042 Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Switch Management... 4 3. Requirements... 5 4.

More information

MDNET-5W. Wi-Fi/Ethernet/RS485 Converter Operation Manual. Version /03/24

MDNET-5W. Wi-Fi/Ethernet/RS485 Converter Operation Manual. Version /03/24 MDNET-5W Wi-Fi/Ethernet/RS485 Converter Operation Manual Version 01.00 2016/03/24 I. Features & Specification Features: Connect RS485 devices to Ethernet or Wi-Fi network Connect Ethernet device to Wi-Fi

More information

STE-708 & STE-716 Series

STE-708 & STE-716 Series Antaira Industrial Serial Device Server Series STE-708 & STE-716 Series 1U 19 Rackmount Industrial Serial Device Servers 8/16-Port Industrial RS232 and RS422/485 Serial Device Servers with Dual LAN User

More information

Configuring the Catalyst 3920

Configuring the Catalyst 3920 CHAPTER 5 Configuring the Catalyst 3920 You might not have to configure the Catalyst 3920 for it to work in your network; it is shipped with default configuration parameters and can function with these

More information

Product Family: Networking Hardware Number: AN-NH-012

Product Family: Networking Hardware Number: AN-NH-012 APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data

More information

L2+ Managed Gigabit Switch WGSW series

L2+ Managed Gigabit Switch WGSW series L2+ Managed Gigabit Switch WGSW-24040 series Quick Installation Guide Table of Contents 1 Package Contents... 3 2. Requirements... 4 3. Terminal Setup... 5 3.1 Logon to Console... 6 3.2 Configuring IP

More information

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL ETOR-4 Ethernet/Serial Gateway USER MANUAL 1 TABLE OF CONTENTS SECTION 1 GENERAL INFORMATION...6 SECTION 2 INSTALLATION...9 2.1 Definitions on ETOR... 9 2.2 Configuring ETOR...10 2.3 Required Installations

More information

Configuring Terminal Settings and Sessions

Configuring Terminal Settings and Sessions This chapter describes how to manage the terminal settings and sessions on a Cisco NX-OS device. This chapter includes the following sections: Information About Terminal Settings and Sessions, page 1 Licensing

More information

ETH002-2 Relays at 16A Technical Documentation

ETH002-2 Relays at 16A Technical Documentation ETH002-2 Relays at 16A Technical Documentation Overview The ETH002 provides two volt free contact relay outputs with a current rating of up to 16Am. The module is powered from a 12vdc supply which can

More information

NordField Electronics

NordField Electronics NordField Electronics XS1000 TCP/IP to RS232/422/485 Device Server Overview and quick info sheet 3.0. Hardware Installation & Initial Setup 3.1 RS-232 Configuration:(DB9 Male) (DB9Male) Signal I/O PIN2

More information

Initial Configuration for the Switch

Initial Configuration for the Switch Options for Initial Configuration, page 1 Configuring the Switch Using the Web User Interface, page 1 Configuring the Switch Using the CLI, page 4 Configuring the Switch in the ROMMON Mode, page 12 Options

More information

MDC 700 Series User Manual

MDC 700 Series User Manual MDC 700 Series User Manual November 2014, Version 1.00 The MDC 700 series module is a Modbus Data Concentrator that has the ability to communicate with up to 127 Modbus slave devices using Modbus RTU protocol.

More information

RAD XD and RAD XD-WM a/b/g Transceiver with Serial Link Quick Start Guide

RAD XD and RAD XD-WM a/b/g Transceiver with Serial Link Quick Start Guide RAD-80211-XD and RAD-80211-XD-WM 802.11a/b/g Transceiver with Serial Link Quick Start Guide 1 This Quick Start Guide is intended to provide adequate information necessary to get a functional system operating.

More information

May 2016 Version 1.2.7

May 2016 Version 1.2.7 May 2016 Version 1.2.7 2 Introduction Copyright Copyright 2016 4RF Limited. All rights reserved. This document is protected by copyright belonging to 4RF Limited and may not be reproduced or republished

More information

SICOM3171 Series Managed Traffic Ethernet Serial Server. Software Operation Manual

SICOM3171 Series Managed Traffic Ethernet Serial Server. Software Operation Manual SICOM3171 Software Operation Manual 201009 SICOM3171 Series Managed Traffic Ethernet Serial Server Software Operation Manual KYLAND Technology Co., Ltd. 1 SICOM3171 Software Operation Manual 201009 SICOM3171

More information

SB72EX User's Manual

SB72EX User's Manual etburner SB72EX User's Manual Revision: 1.8 October 8, 2009 SB72EX User's Manual, 350030-001 Table of Contents Table of Contents...2 Overview of the SB72EX Dual-port Serial to Ethernet Device... 3 Overview

More information

Canlan INSTALLATION MANUAL

Canlan INSTALLATION MANUAL Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...

More information

DMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE

DMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE DMC-1002 SNMP Module for Chassis-Based Media Converter Manual Rev. 01 (JUN. 2002) 1907MCB10016000 RECYCLABLE TABLE OF CONTENTS ABOUT THIS GUIDE... 2 FEATURES...2 UNPACKING...2 CONFIGURING THE SYSTEM...

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

GW1000-DHPA: ASCII to DH+ Setup

GW1000-DHPA: ASCII to DH+ Setup GW1000-DHPA: ASCII to DH+ Setup The following is a brief description of the GW1000-DHPA ASCII Printer to DH+ interface. Version 1.05 has ASCII printer mode enabled; future release will combine printer

More information

L2+ Managed Metro Ethernet Switch MGSW / MGSD Series

L2+ Managed Metro Ethernet Switch MGSW / MGSD Series L2+ Managed Metro Ethernet Switch MGSW / MGSD Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5 4. Terminal Setup... 6 5. Logon

More information

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual HOME AUTOMATION, INC. Model 93A00-1 Serial Server User s Manual Document Number 93I00-1 Rev. A December, 2009 Introduction The 93A00-1 is a RS232/RS485 to TCP/IP converter integrated with a robust system

More information

tgw-700 Series User Manual Warranty Warning Copyright Trademark

tgw-700 Series User Manual Warranty Warning Copyright Trademark tgw-700 Series User Manual Tiny Modbus/TCP to RTU/ASCII Gateway Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery

More information

ATK3 I/O Module (Modbus Slave)

ATK3 I/O Module (Modbus Slave) ATK3 I/O Module (Modbus Slave) 2011-01-13 The ATK3 I/O Module by ElectroCom Table of contents 2011-01-13...1 The ATK3 I/O Module by ElectroCom...1 1 Hardware...2 1.1 Inputs...3 1.2 Outputs...3 1.2.1 Relay...3

More information

EGW1-IA3-MB User s Manual

EGW1-IA3-MB User s Manual www.exemys.com Rev. 0 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information

More information

Any device, including routers and hosts, is running an implementation of IP address Host

Any device, including routers and hosts, is running an implementation of IP address Host INSTRUCTION MANUAL IM471-U v0.1 EMI-10L Introduction EMI-10L converter lets you convert a serial RS485 communications port on a bus Ethernet with TCP / IP. The concepts and terms commonly used in the TCP

More information

ABLELink. Modbus Gateway MB5000 Series User s Manual

ABLELink. Modbus Gateway MB5000 Series User s Manual ABLELink MB5000 Series User s Manual Version 1.1 Updated in March, 2010 TEL: 886-3-5508137 FAX: 886-3-5508131 http://www.atop.com.tw Table of Contents Table of Contents... 2 Introduction... 4 Features...

More information

ECOV-110 User s Manual

ECOV-110 User s Manual ECOV-110 User s Manual 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ECOV-110 Firmware upgrade ECOV-110 1. ECOV-110 Product Introduction: 1.1.

More information

WiFi to RS-422/485 adapter user manual

WiFi to RS-422/485 adapter user manual WiFi to RS-422/485 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-422/485 adapter x 1 2 dbi dipole antenna x 1 A4 User manual x 1 USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm)

More information

tgw-700 Series User Manual

tgw-700 Series User Manual tgw-700 Series User Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

USER MANUAL FOR GS100/GS1003G

USER MANUAL FOR GS100/GS1003G USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...

More information

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter APCON100 series Operation Manual RS-232 to Ethernet Converter Page 1 of 24 APCON100 series Operation Manual Index Chapter 1 Specifications 2 Chapter 2 Introduction 3 Chapter 3 Easy Installation 4 Chapter

More information

25-Port Fast Ethernet Switch

25-Port Fast Ethernet Switch TigerSwitch 10/100 25-Port Fast Ethernet Switch 24 10BASE-T/100BASE-TX ports and 1 MMF 100BASE-FX port Optional 100BASE-FX or 1000BASE-X modules 8.8 Gbps aggregate bandwidth Non-blocking switching architecture

More information

Industrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS T2S/IGS UP1T2S IGS P2S/IGS P4S/IGS P2T2S

Industrial L2+ Multi-Port Full Gigabit. Managed Ethernet Switch IGS T2S/IGS UP1T2S IGS P2S/IGS P4S/IGS P2T2S Industrial L2+ Multi-Port Full Gigabit Managed Ethernet Switch IGS-5225-4T2S/IGS-5225-4UP1T2S IGS-5225-8P2S/IGS-5225-8P4S/IGS-5225-8P2T2S Quick Installation Guide Table of Contents 1. Package Contents...

More information

L2+ Managed PoE Switch GS-5220 PoE Series

L2+ Managed PoE Switch GS-5220 PoE Series L2+ Managed PoE Switch GS-5220 PoE Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 5 3. Terminal Setup... 6 4. Logon to Console... 7 5. Configuring IP Address...

More information

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing the Cisco Unified Videoconferencing 3545 MCU CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)

More information

Industrial 4G LTE Cellular Gateway ICG-2420-LTE

Industrial 4G LTE Cellular Gateway ICG-2420-LTE Industrial 4G LTE Cellular Gateway ICG-2420-LTE Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Starting Web Management... 5 4. Terminal Setup... 8 4.1. Logon

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

ftp://riksun.riken.go.jp/pub/pc/misc/terminal/teraterm/ ftp://ftp.s.u-tokyo.ac.jp/pc/terminal/teraterm/

ftp://riksun.riken.go.jp/pub/pc/misc/terminal/teraterm/ ftp://ftp.s.u-tokyo.ac.jp/pc/terminal/teraterm/ 1827 Ver. 1. Preparation for setting. For safety, prepare Ethernet network environment that is free from external network, personal computer that can be connected to the network, and basic software terminal

More information

ilo MP Utilities ilo MP

ilo MP Utilities ilo MP The Integrated Lights-Out Management Processor () offers remote server management through an independent management processor (MP). It provides a way for you to connect to a server and perform administration

More information

tgw-700 Series User Manual

tgw-700 Series User Manual tgw-700 Series User Manual Ver. 2.2, Nov. 2017 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original

More information

Aruba Quick Start Guide

Aruba Quick Start Guide Aruba Quick Start Guide Before you can access the Web-based Web UI tools, which is the primary configuration interface for Aruba Mobility Controllers, the switch must be configured with basic system information

More information

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

Setting Up Your Cisco Unified Videoconferencing 3515 MCU CHAPTER 2 Setting Up Your Cisco Unified Videoconferencing 3515 MCU This section describes the following topics: Physical Description, page 2-1 Preparing for Installation, page 2-2 Verifying the Package

More information

Appendix. CLI Commands. In This Appendix...

Appendix. CLI Commands. In This Appendix... CLI Commands Appendix D In This Appendix... Introduction... D 2 Accessing the CLI... D 2 CLI Commands:... D 3 Global Commands:... D 3 Access Configuration:... D 3 Alarm Configuration:... D 4 Modbus Configuration:...

More information

GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet

GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet GE Security GE-DSH-73/82 and 82-POE Managed Switch Installation Sheet Package Contents Thank you for purchasing the GE Security 7/8-Port Fast Ethernet + 2/3-Port Gigabit TP/SFP Combo Managed Switch. The

More information

DS Manager IP Setup For use with Hall Research Products. Table of Contents

DS Manager IP Setup For use with Hall Research Products. Table of Contents DS Manager IP Setup For use with Hall Research Products Table of Contents 1. Introduction... 1 1.1 General... 1 2. Installation... 2 2.1 Download the DS Manager Installation... 2 3. Configuration... 3

More information

SSE232-LE Serial Server- User s Manual

SSE232-LE Serial Server- User s Manual www.exemys.com Rev.6 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information

More information

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual GW-7472 / GW-7473 EtherNet/IP to Modbus RTU/TCP Gateway User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, starting from

More information

ecov-110 User s Manual (V0.9f_Eng)

ecov-110 User s Manual (V0.9f_Eng) ecov-110 User s Manual (V0.9f_Eng) 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ecov-110 Firmware Upgrade Appendix B. ecov-110 Serial Advanced

More information

SD24GS. 24-Port Web Smart Gigabit Ethernet Switch. User s Manual

SD24GS. 24-Port Web Smart Gigabit Ethernet Switch. User s Manual SD24GS 24-Port Web Smart Gigabit Ethernet Switch User s Manual FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC

More information

J1939/Modbus Slave Gateway FAQ

J1939/Modbus Slave Gateway FAQ J1939/Modbus Slave Gateway FAQ Version 1.0 (For GW-7228/GW-7238D) ICP DAS Co., Ltd. Table of Contents J1939/Modbus Slave Gateway FAQ v1.0 Q01 : How to solve CAN Bus Transmission Fail problem?... 2 Q02

More information

TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0

TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0 TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0 MILLENNIUM TECHNOLOGIES 440, MASTER MIND 1, ROYAL PALMS ESTATE AAREY MILK COLONY, GOREGAON (EAST), MUMBAI-400065. INDIA. PH: - 91-22-65229736,

More information

Troubleshooting 1240AG Series Autonomous Access Points

Troubleshooting 1240AG Series Autonomous Access Points CHAPTER 3 Troubleshooting 1240AG Series Autonomous Access Points This chapter provides troubleshooting procedures for basic problems with the 1240AG series autonomous access point (AIR-AP1242AG or AIR-AP1242G).

More information