1782-JDC DeviceNet Serial Gateway User s Manual

Size: px
Start display at page:

Download "1782-JDC DeviceNet Serial Gateway User s Manual"

Transcription

1 1782-JDC DeviceNet Serial Gateway User s Manual Western Reserve Controls, Inc.

2 Although every effort has been made to insure the accuracy of this document, all information is subject to change without notice. Western Reserve Controls, Inc. assumes no liability for any errors or omissions in this document or for direct, indirect, incidental or consequential damage resulting from the use of this document. Document 25.0 Rev 5.13 September 2011 Copyright WRC Western Reserve Controls, Inc Exeter Road Akron OH (Phone) (FAX) ( ) (Web) WRC is a trademark of Western Reserve Controls, Inc. DeviceNet is a trademark of ODVA, Inc. All other trademarks are property of their respective companies. i

3 TABLE OF CONTENTS 1. OVERVIEW FEATURES PRODUCT FAMILY SELECTION DEVICENET SYSTEM ARCHITECTURE BASIC OPERATION Polled I/O Explicit Messages Cyclic Input Message Change-of-State, or COS DEFAULT DEVICE CONFIGURATION PRODUCT VERSION AND EDS QUICK START HOW TO INSTALL AND ESTABLISH DEVICENET COMMUNICATIONS HOW TO CHANGE THE NODE ADDRESS HOW TO CHANGE THE BAUD RATE HOW TO INSTALL A SERIAL NETWORK HOW TO READ SERIAL DEVICE INPUT DATA FROM THE JDC HOW TO WRITE SERIAL OUTPUT DATA TO THE JDC GENERAL SPECIFICATIONS HARDWARE INSTALLATION AND SET-UP OVERVIEW LED OPERATION DeviceNet LEDs Serial Port LEDs SERIAL PORT CONNECTOR DEVICENET CONFIGURATION DeviceNet Network Termination DeviceNet Connection Wiring RS485 Network Termination (1782-JDC-2) SOFTWARE CONFIGURATION AND SET-UP SETTING UP SERIAL COMMUNICATIONS Setting up the serial link baud rate Setting up the receive delimiter Setting up the transmit delimiter Setting up the Data Frame Format Setting up the Receive Character Buffer Length Setting up the Transmit Character Buffer Length Setting up the Pad Mode Setting up the Pad Character Using the Swap Bytes Mode Transmitting Serial Data ASCII Receive Data and Pad Mode SETTING UP DEVICENET COMMUNICATIONS Polled I/O Cyclic and Change-of-State I/O Setting up the DeviceNet I/O Connections Setting up the Connection Timer (EPR) ii

4 5.2.5 Autobaud Operation Setting up the DeviceNet Baudrate A. DEVICENET PROFILE, OBJECTS AND SERVICES A JDC DEVICENET PROFILE A.2 SERIAL I/O POLLED DATA FORMATS A.3 IDENTITY OBJECT, CLASS A.4 PARAMETER OBJECT, CLASS FHEX (15DEC) A.5 COMMON DEVICENET SERVICES B. ACCESSORIES AND OTHER WRC PRODUCTS C. FREQUENTLY ASKED QUESTIONS D. TROUBLESHOOTING LIST OF TABLES TABLE 1-1 I/O MESSAGE TYPES... 6 TABLE 2-1 BAUD RATE SELECTION... 9 TABLE 2-2 DEVICENET CONSUME ASSEMBLY / SERIAL TRANSMIT DATA STRING TABLE 2-3 SERIAL RECEIVE STATUS/ERROR BYTE TABLE 2-4 DEVICENET CONSUME ASSEMBLY / TRANSMIT DATA STRING TABLE 4-1 MODULE STATUS LED (LABELED MS) TABLE 4-2 NETWORK STATUS LED (LABELED NS) TABLE 4-3 RS-232/485 CONNECTOR SIGNALS TABLE 4-4 RS422/485 CONNECTOR SIGNALS TABLE 4-5 MAXIMUM NETWORK CABLE LENGTHS TABLE 5-1 CONFIGURATION PARAMETER LIST TABLE 5-2 SERIAL BAUDRATES TABLE A-1 DEVICENET OBJECTS TABLE A-2 POLL PRODUCE DATA (ASCII RECEIVE STRING) TABLE A-3 POLL CONSUME DATA (ASCII TRANSMIT STRING) TABLE A-4 IDENTITY OBJECT CLASS ATTRIBUTES (INSTANCE 0) TABLE A-5 IDENTITY OBJECT INSTANCE ATTRIBUTES (INSTANCE 1) TABLE A-6 IDENTITY OBJECT COMMON SERVICES TABLE A-7 PARAMETER CLASS ATTRIBUTES (INSTANCE 0) TABLE A-8 PARAMETER INSTANCE ATTRIBUTES (INSTANCES 1-7) TABLE A-9 PARAMETER COMMON SERVICES TABLE A-10 JDC PARAMETER INSTANCES (CLASS F HEX ) TABLE B-1 WRC REPLACEMENTS, SPARE PARTS AND OTHER PRODUCTS TABLE OF FIGURES FIGURE JDC... 4 FIGURE JDC OUTLINE DRAWING FIGURE 4-2 DEVICENET CABLE CONNECTOR iii

5 1. Overview The 1782-JDC is a family of DeviceNet-to-serial link communications gateways that provide a flexible DeviceNet interface to a wide variety of ASCII devices. The JDC allows the user to easily and conveniently connect and integrate peripheral products with RS232, RS422 or RS485 serial ports into a DeviceNet system. Using the JDC you may communicate with the connected peripheral devices in the same fashion as the other DeviceNet products in the system. Data may be read/written using either I/O polling or explicit messaging. Typically real-time data is read and written as I/O by the DeviceNet Master via Polled I/O and parameters are read and written with the Explicit Messaging technique. The 1782-JDC is defined as a Communications Adapter device on the DeviceNet system. It has a 3-pin plug connector for connection to RS232 (JDC-1) or RS485 (JDC-2) or a 5-pin plug connector for connection to RS422/485 (JDC-4) interface port on your device and a 5-pin pluggable DeviceNet connector for connections to the DeviceNet network. The device does baud rate selection automatically when it is powered up on a network. The 1782-JDC has one assigned DeviceNet address, which is set by a 6-position DIP switch on the unit. Other JDC parameters are software-configurable and are changed from their default values by third-party DeviceNet configuration tools. Each 1782-JDC has 2 standard green/red DeviceNet LED s for module status and network status and two green LED s to indicate RS232/422/485 transmit and receive activity. The RS232 version may be used for point-to-point connection to a single serial device. The RS422/485 version may be connected in a point-to-point fashion to a single device, or to multiple devices in the standard RS422/485 convention. The JDC is a general-purpose gateway that is completely device-independent. The JDC does not interpret the data being transmitted across it, and so the transferred messages may contain data of any nature or definition. This allows you to use the same device for a wide variety of DeviceNet-serial interface applications. This manual applies to 1782-JDC version 5. Figure JDC 4

6 1.1 Features The 1782-JDC has the following features: Translates messages and data between DeviceNet and a serial peripheral device ODVA Group 2 Only Slave Defined as a DeviceNet Communications Device Profile 12 (C hex ) Autobaud operation Polled I/O and Explicit Messaging Software Configurable Parameters for serial port operation Special mode performs byte swapping of serial message for AB PLC compatibility Address selection via DIP switches DIN rail mount Pluggable 5-pin DeviceNet connection Pluggable RS pin connection / RS pin connection / RS pin connection 2 standard DeviceNet module and network status LED s 2 serial transmit and receive LED s Powered from DeviceNet Vdc network power ASCII string length up to 124 bytes Serial port baud rate up to 38.4k baud Network electrical isolation 1.2 Product Family Selection There are 3 members of the 1782-JDC family: o 1782-JDC-1 Isolated RS-232 o 1782-JDC-2 Isolated RS-485 o 1782-JDC-4 Isolated RS-422/ DeviceNet System Architecture A DeviceNet network is a distributed I/O system that may contain many different products from several different vendors. Products may be configured uniformly, as clusters or as distributed clusters. Up to 64 devices, including the master may be attached to a single DeviceNet network. Any of these, except the master, may be a JDC. A typical system will include a master, such as a PLC or industrial PC, and multiple slave devices, including a 1782-JDC with connected peripheral devices. 5

7 1.4 Basic Operation The JDC operates as the DeviceNet front-end to the serial device(s). Connecting the JDC to a single device, that device can then be assigned by the system implementer to one specific master. The DeviceNet Master can receive and send data to and from the 1782-JDC via the methods described in this section. It formats and sends the data to the device and likewise accepts responses from the device, which are reformatted and passed back to the DeviceNet system as required. The JDC has one DeviceNet address. All DeviceNet messages to the JDC itself (to read / write its internal data) are sent to this address. All DeviceNet messages to and from the serial device are sent to the JDC DeviceNet assembly objects using poll commands. The JDC Parameter Object allows you to define the specific operation of each JDC. These parameters include all the set-up required for the serial comm. link. The following chart defines the various messaging methods used for typical data types at your serial device and a brief explanation follows. Table 1-1 I/O Message Types Typical Data Polled Cyclic Bit-Strobe Change-of-State Explicit Message Commands Status Parameters Polled I/O The DeviceNet Master uses the JDC s predefined polled IO connection to send input and output data to the JDC. The input data to the JDC has a one-byte record number, a one-byte length indicator and up to 124 additional bytes of transmit data. When a poll is received and the record has changed since the last poll was sent, the JDC sends the associated transmit data out the serial port to the remote ASCII device. When the JDC receives serial data from a device on the serial link, the poll response data to the Master contains a one byte record number, then a one byte status number that reflects errors or events on the bus, a one byte length indicator that is the length of the message in the response and up to 124 bytes of received data. The record number is incremented in the poll response when new data is received on the serial link. The status byte is zero if no errors occurred Explicit Messages As mentioned, explicit messages are typically used to read and write configuration data. This data allows the JDC to change its internal operating parameters such as baudrate and parity. The JDC does not allow for direct communication to the serial ports using explicit messaging Cyclic Input Message Cyclic I/O is the function by which a slave device sends its input data to the master at a specific time period without the host explicitly requesting it. When the specified time interval (defined by you) elapses, the user-specified input data are transmitted to the master. This data is the same format as a poll response. 6

8 1.4.4 Change-of-State, or COS COS I/O is the function by which a slave device sends its input data to the master when defined input data changes without the host explicitly requesting it. In the case of the JDC, this occurs when the delimiter character is asynchronously received from the serial device. This data is the same format as a poll response. 1.5 Default Device Configuration The 1782-JDC DeviceNet address is read from the switches and is set to 63 at the factory. All other parameters are software settable. The default settings for the 1782-JDC are provided in the discussion of the Parameter Object. 1.6 Product version and EDS This manual applies to 1782-JDC-x version 5 and higher. An EDS (Electronic Data Sheet) for the 1782-JDC, is shipped with your device or is available on WRC s web site: 7

9 2. Quick Start To quickly install your 1782-JDC in your DeviceNet system, follow the instructions below. For more details, see Section How to Install and Establish DeviceNet Communications 1. Connect your DeviceNet network cable to a 5-pin female (Phoenix-type) plug according to DeviceNet cable wiring specifications 2. Make sure that the DeviceNet network is terminated properly. 3. The JDC Node Address (MacID) is set to 63 at the factory. Make sure no other device on the network is set to 63, or change the JDC address to one that is not currently used (see below). 4. The JDC baud rate is set to Autobaud operation at the factory. See below to change it to a fixed baud rate if desired. 5. Make sure that there is power on the DeviceNet network and plug the cable into the JDC. 6. The 1782-JDC will undergo its initialization sequence, flashing both LED s red and green. After approximately 5 seconds, the Module Status LED (labeled MS ) will flash green. The Network Status LED (labeled NS ) will remain off. This condition occurs while the JDC is attempting to synchronize to the network baud rate. 7. The Module Status LED ( MS ) will go on solid after the Device successfully determines the network baud rate. This requires devices on the network attempting to communicate with each other. The Network Status LED (labeled NS ) will begin to flash green. If it turns solid red, check for a duplicate MacID on the network. If it remains off, make sure that there are other devices trying to communicate on the network. 8. Once the Master recognizes the unit on the link and allocates the connection (initiates communications), The Network Status LED will be solid green. The device is now being actively scanned. 9. The 1782-JDC is now operating on the network. 2.2 How to Change the Node Address 1. Set the 6-position DIP switch to the binary number representing the desired Node Address, (Note: Address 0 is often reserved for a Master device.) 2. Power cycle the unit by unplugging and reconnecting the DeviceNet cable. NOTE: The new address will not become effective until the unit is power cycled or a Reset command is received from the Master. 2.3 How to Change the Baud Rate The Baud Rate is set to autobaud at the factory. The baud rate can be changed through your configuration tool in its normal manner to any baud rate except autobaud. This is due to the fact that autobaud is not provided for in the DeviceNet specification. If you need to set the 8

10 baud rate to autobaud, you must do it via the parameter object. The definition is included in the EDS file for easy configuration. Just use your configuration tool to access the device parameters. The baud rate is parameter 7. Select the proper baud rate and upload the parameter to the device. If your configuration tool does not support EDS parameter configuration, you will have to perform the operation manually. To do this, set the parameter Class 15 (F hex ), instance 7, attribute 1 to the value in Table 2-1. NOTE: If you change the baud rate, the new baud rate will not become effective until the unit is power cycled or a reset command is received by the Identity Object (Class 1, Instance 0, reset). Table 2-1 Baud Rate Selection Baud Rate Value Baud Rate 0 125k 1 250k 2 500k 3 Autobaud 2.4 How to Install a Serial Network 1. The communication between your serial device(s) and the 1782-JDC is a RS232 3-wire, RS485 2-wire or 5-wire RS422/485 differential network. Connect an appropriate cable to your device. 2. Connect the other end of the cable to the JDC using the 3-point or 5-point terminal plug provided. Note the terminal markings on the JDC case. See Figure Turn on power to the serial device and the JDC. 4. Set up the ASCII buffer sizes on the JDC. (The defaults are 20 and 20). If more than 20 bytes are required for the transmit or receive buffers, set parameters 5 and 6 in your configuration file to the buffer size you need for your ASCII data (NOTE: this will modify the IO message size. You will need to reconfigure the poll / COS / cyclic transmit and receive data sizes if you modify the ASCII buffer size from the default value. In many configuration tools, this will unmap the data in your scanner s scan table. They must be remapped in order to be able to process the data in your PLC or software) These parameters can be reached in the Parameter Class 15 (F hex ), Instances 5 and 6, Attribute 1 if you need to configure these manually (See Table A-10). 2.5 How to Read Serial Device Input Data from the JDC 1. Set up the receive size of your connection to equal the (Max Number of Receive Chars + 3) in your Master s scan table. The default value should be 23 (20+3). 2. Map the data from your IO response to your scanners memory map. The device s response is byte aligned. The first byte indicates the receive record of the data. The second byte contains the JDC's serial status indicator (00 is normal). The third byte contains the length of the message being transmitted by the JDC. The subsequent bytes contain the serial buffer data from the serial input until and including the latest received 9

11 delimiter. The response is only updated when the delimiter is received or a buffer overflow occurs. Every time the buffer is updated (e.g. the delimiter received or an overflow condition) the record number will be incremented. The data is only valid up to the received delimiter in your memory map. Data after the received delimiter may contain invalid data. 3. Direct the master to begin polling the JDC. Once the first delimiter is received, the master s memory will reflect data received by the JDC. The data returned will have the following pattern: Table 2-2 DeviceNet Consume Assembly / Serial Transmit Data String BYTE Byte 1 Byte 2 Byte 3 MEANING Record Counter Serial Port Status String Length (number of data bytes) Byte 4 ASCII Character 1. Byte 23 ASCII Character 19. Byte 127 ASCII Character 124 The status/error byte represents the status of the ASCII data record received from the ASCII device. This byte is defined as follows: Table 2-3 Serial Receive Status/Error Byte Byte Value Meaning 0 No error 1 Buffer Overflow 2 Parity Error 3 Buffer Overflow and Parity Error 2.6 How to Write Serial Output Data to the JDC 1. Set up the transmit size of your connection to equal the buffer size of the ASCII transmit buffer plus 2. (Default is 22 bytes) 2. Map the IO transmit data of the JDC. The first byte of the JDC s IO transmit array is the record number. This value should be set to 0 at the beginning of communications. The second byte is a length indicator, followed by the number of data bytes. The ensuing bytes are the data that you wish to send to the JDC. If the length is set to 0 the JDC will send 10

12 all of the consecutive bytes up to and including the delimiter after the transmit record number has changed. If the length is non-zero, the JDC will send up to the number of bytes specified by the length without regard to the transmit delimiter and ignoring any junk characters after the specified amount of bytes. The format is: Table 2-4 DeviceNet Consume Assembly / Transmit Data String BYTE Byte 1 Byte 2 Record Counter MEANING String Length (number of data bytes) Byte 3 ASCII Character 1 Byte 4 ASCII Character 2. Byte 21 ASCII Character 19. Byte 126 ASCII Character Begin scanning the JDC. Enter data that you want to send on the serial link. On receipt of a change to the record number, the JDC will transmit the data. If any data is in the receive buffer, the received data will be returned as a poll response. (If the sequence number is the same as the previous response, the JDC will not re-send the string.) NOTE: If using the Byte-Swap Mode (Parameter 10 set to enabled) all strings being sent must have the length set. Using a zero length will prevent the byte swapping from occurring. 11

13 3. General Specifications Product: Description: 1782-JDC Device-Serial Gateway o o o 1782-JDC-1, Isolated RS JDC-2, Isolated RS JDC-4, Isolated RS-422/485 Communications gateway between a serial capable device over an RS232/422/485 interface and a DeviceNet network. Device Type: Communications Adapter, C hex, (12) Device Profile: Product Revision: 5 DeviceNet Communications: DeviceNet: Identity Object Message Router Object DeviceNet Object Connection Object Parameter Object Serial I/O Object (vendor-specific) Predefined Master/Slave Connection Set, Group 2 Only Server Baud rate selection: Autobaud operation (default) Fixed baud (software selectable) 125k, 250k and 500k baud Address selection: Address number 0 to 63, switch selectable (default = 63) Cable Connection: JDC: 5-pin pluggable header (male) Phoenix Contact MSTBA 2.5/5-G-5.08/AU or equivalent Serial port: DeviceNet Cable: 5-contact plug (female contacts) Phoenix Contact MSTB 2.5/5-ST-5.08/AU or equivalent (included) Status Indicators: Module Status: green/red bi-color LED Network Status: green/red bi-color LED Baud rate: 1200, 2400, 4800, 9600, 19.2k, 38.4k baud (software selectable) Parity: Odd/even/none (software selectable) Data bits: 7 or 8 (software selectable) Cable Connection: JDC: 3-pin or 5-pin pluggable header (male) Phoenix Contact MSTBA 2.5/3-G-5.08/AU or equivalent 12

14 Serial Cable: 3-contact or 5-contact plug (female contacts) Phoenix Contact MSTB 2.5/3-ST-5.08/AU or equivalent (included) Status Indicators: Transmit Active: green LED Receive Active: green LED Network Isolation: Max Power: Mounting: Size: 1000V (optional) 1.75 watts: Vdc Vdc unregulated power supply DIN rail mount, EN (WRC50022) Depth: 3.54 (90 mm) Operating Temp: 0-70 ºC Width: 0.98 (25 mm) Height: 3.11 (79 mm) Humidity: 0-95% RH, non-condensing 13

15 4. Hardware Installation and Set-Up 4.1 Overview The JDC is mounted on an EN50022 DIN rail. The JDC contains two LED s to indicate the status of the device and the status of the network. The device can be connected to the main DeviceNet trunk line or to a drop line via a 5-pin female plug-style connector. It also has two green LED s to indicate the presence of activity on the RS-232/422/485 transmit and receive lines. All power for the JDC is derived from the DeviceNet power JDC DeviceNet Converter KEY TOGGLE ARM 1=LEFT 0=RIGHT RX TX GND ADDR = 0 V+ CAN_H N/C CAN-L V- Figure JDC Outline Drawing 14

16 4.2 LED Operation DeviceNet LEDs The JDC has two LEDs that provide visual status information to the user about the product and the DeviceNet network. See Tables 5-1 and 5-2 that follow below for how to interpret LED status indications. Table 4-1 Module Status LED (labeled MS) LED State Module Status Meaning OFF No Power There is no power through DeviceNet. Green Device Operational JDC is operating normally. Flashing Green Device in Standby JDC needs commissioning (e.g. attempting autobaud). Flashing Red Minor Fault Recoverable fault. Red Unrecoverable Fault JDC may need replaced. Flashing Red/Green Device Self-Testing JDC is in self-test mode. Table 4-2 Network Status LED (labeled NS) LED State Network Status Meaning OFF No Power / Not on-line JDC has no power or has not completed the Dup_MAC_ID test. Flashing Green On-line, not connected JDC is on-line but is not allocated to a Master. Green On-line JDC is operating normally. Flashing Red Connection time-out One or more I/O connections are timed out. Red Critical link failure JDC has detected an error that makes it incapable of communicating on the link. (Bus off or Duplicate MAC ID) Serial Port LEDs The JDC also has two (2) RS-232/422/485 activity LEDs: one for transmit (TX) and one for receive (RX). Each of these will illuminate when there is data communications active on the respective data lines. 15

17 4.3 Serial Port Connector The ASCII devices are connected to the JDC via a 3-wire or 5-wire communications cable. See your ASCII device s User Manual for details on the proper connections. The RX and TX designators are referenced with respect to the JDC. Table 4-3 RS-232/485 Connector Signals Pin # Designator RS232 RS485 (RS232/RS485) Signal Signal 3 RX/SG- Receive Signal - 2 TX/SG+ Transmit Signal + 1 GND Ground Shield Table 4-4 RS-422 Connector Signals Pin # Designator RS422 Signal 5 TX- Transmit - 4 TX+ Transmit + 3 GND Ground 2 RX- Receive - 1 RX+ Receive DeviceNet Configuration DeviceNet specifications provide for a maximum network distances for the main trunk line and drop lines, depending upon the baud rate used on the network. See Table 4-5 Table 4-5 Maximum Network Cable Lengths Trunk Line Length Drop Length Maximum Distance Maximum Cumulative Baud Rate Meters Feet Meters Feet Meters Feet 125k baud 500 m 1640 ft 6 m 20 ft 156 m 512 ft. 250k baud 250 m 820 ft 6 m 20 ft 78 m 256 ft. 500k baud 100 m 328 ft 6 m 20 ft 39 m 128 ft DeviceNet Network Termination A DeviceNet system must be terminated at each end of the trunk line. The host controller and the last JDC or other DeviceNet device on the network must always be terminated to eliminate reflections, even if only two nodes are present. The DeviceNet specifications for the terminating resistor are: 16

18 o o o 121 ohm 1% metal film 1/4 Watt An appropriate terminating resistor, WRC part number RM121DN, may be purchased from WRC. IMPORTANT: Per the DeviceNet spec -- do not terminate devices on drop lines DeviceNet Connection Wiring The JDC uses a 5-pin plug-style DeviceNet connector, which has male pins. Figure 4-2 DeviceNet cable connector RS485 Network Termination (1782-JDC-2, 1782-JDC-4) It is common practice to terminate an RS485 network system at each end of the serial cable to eliminate electrical reflections. An appropriate value for the terminating resistor typically is: ohm, depending upon the characteristic impedance of the cable used o 121 ohms (same value as the DeviceNet terminator) is a standard resistor value that may be used in many cases 1% metal film 1/4 Watt Correct cable termination is the responsibility of the user. The 1782-JDC-2 does not include an internal terminating resistor. Note: 1782-JDC-2 products shipped with date code 0338 and earlier may have an internal 220-ohm terminating resistor installed. If you have any questions about this, please contact WRC by phone or at support@wrcakron.com. 17

19 5. SOFTWARE Configuration and Set-Up The 1782-JDC-x is an easy device to set up and configure. Using features like the EDS sheets for configuration can expedite the process if you use a network configuration tool that supports them. They provide a graphical interface to the device s parameters and allow the addition of helpful text descriptions in setting up your device. The current EDS file is available on our website, If your configuration tool does not support the EDS device profiles, the set up of a DeviceNet device requires a little more understanding of DeviceNet and its operation. This section is designed to fully describe the features of the 1782-JDC and to help you set them up. If you have problems setting up a device, we are available to help you. We can be reached via phone at (330) , or via the Internet at support@wrcakron.com. The Parameters are defined in this section. 18

20 Table 5-1 Configuration Parameter List Parameter Param. Instance Access Description Parameter Choices Default Setting Default Value Data Type Serial Character Format Serial Baud Rate Receive Delimiter 1 Get/Set Character framing 2 Get/Set 3 Get/Set RS232/RS422/RS485 communications speed Character which identifies the end of the data string from the ASCII device when the length is specified as 0 0 = 7N2 1 = 7E1 2 = 7O1 0 = = = = 8N1 4 = 8N2 5 = 8E1 6 = 8O1 3 = = 19.2k 5 = 38.4k Any valid standard ASCII character (0 127, 0-255) 7N2 0 USINT 9600 baud 0 USINT Carriage return D hex USINT Transmit Delimiter 4 Get/Set Character which identifies the end of the transmit data string to the ASCII device when the length is specified as 0 Any valid standard ASCII character (0 127, 0-255) Carriage return D hex USINT Max Number of Receive Chars 5 Get/Set Maximum number of characters the JDC expects to receive into its ASCII port from the serial device chars 14 hex USINT Max Number of Transmit Chars 6 Get/Set Maximum number of characters the JDC expects to transmit out its serial port to the serial device chars 14 hex USINT Device Net Baud Rate 7 Get/Set The baud Rate of the device net device. The baud rate can be set here and will take effect once the JDC has been reset. 0 = 125 Kbaud 1 = 250 Kbaud 2 = 500 Kbaud 3 = Autobaud Autobaud 3 USINT Pad Mode 8 Get/Set Indicates whether to pad the invalid data region after the delimiter with the pad character, or to use variable length I/O responses 0 = Pad Mode Disabled 1= Pad Mode Enabled Enabled 1 USINT Pad Character 9 Get/Set The value to use to pad the invalid data portion of the poll response Any valid standard ASCII character (0 127, 0-255) NULL 0 USINT Swap Bytes 10 Get/Set If enabled, the position of the bytes in the serial messages will be swapped every 2 or 4 bytes. 0 = Disabled 1 = 16 bit Swap Enabled 2 = 32 bit Swap Enabled Disabled 0 USINT 19

21 5.1 Setting up Serial Communications Setting up the serial link baud rate The standard baud rates are supported by the JDC, starting at 1200 baud and going to baud. The baud rate is configured at parameter 2 of the parameter object. The valid options are: Table 5-2 Serial Baud rates Value Baud Rate Setting up the receive delimiter The receive delimiter is an end-of-string character. It is used by the JDC to determine that the last expected character from the ASCII device has been received. Upon receipt of this character, the JDC updates its internal data buffer on the serial receive side and transmits this new string to the DeviceNet system. It is also used by the DeviceNet sections of the device to determine when the device should generate a COS triggered message over the DeviceNet network, if COS has been selected. The receive delimiter can be set to any valid ASCII character that can be received over the link. Be very careful not to set the delimiter to a value outside of the valid range for your data bits (Note: A data bit size setting of 7 will only allow you a delimiter range of dec., 00-7F hex ). If you do not have a valid receive delimiter, or the receive delimiter is never received, the device will only update the output buffer on detection of an overflow condition, that is, when it has received the number of characters defined in max_number_of_receive_chars, defined in Parameter 5. These values can be set and retrieved by using the standard set and get services on class 15 (F hex ), instance 3, attribute 1 (See Table 5-1) Setting up the transmit delimiter The transmit delimiter is an end-of-string character which is used by the JDC to determine how many bytes to transmit over the serial link to your ASCII device. If the buffer length is not 0 the JDC will ignore the transmit delimiter. The JDC will transmit up to and including the delimiter when the above condition is met. The transmit delimiter can be set to any valid ASCII character that can be received over the link. Be very careful not to set the delimiter to a value outside of the valid range for your data bits (Note: A data bit size setting of 7 will only allow you a delimiter range of dec., 00-7Fhex). If you do not have a valid delimiter, or the delimiter is never received, the device will only update the output buffer on detection of an overflow condition. These values can be set and retrieved by using the standard set and get services on class 15 (F hex ), instance 4, attribute 1 (See Table 5-1). 20

22 5.1.4 Setting up the Data Frame Format The data frame format parameter defines the size of the data frame that is transmitted and received over the serial link. This parameter defines the number of data bits per character (7 or 8), the parity (odd, even or none) and the number of stop bits (1 or 2). The JDC provides several options that can be used to match the choice(s) available with your ASCII device, as the setting on both the JDC and your ASCII device must match exactly. These values can be set and retrieved by using the standard set and get services on class 15 (F hex ), instance 1, attribute 1 (See Table 5-1) Setting up the Receive Character Buffer Length The receive character buffer length is the number of characters that the JDC can receive from your ASCII device into its buffer before generating an overflow and forcing the data into the JDC DeviceNet transmit buffer. This size value also determines the maximum size of the poll response to the Master from the JDC and is determined by: produce_size = receive_character_length + 3 The valid settings for this value are The default value is 20 (14 hex ). This produce_size is used to set up the Poll, Cyclic and/or COS receive (response) sizes at your Master device. These values can be set and retrieved by using the standard set and get services on class 15 (F hex ), instance 5, attribute 1 (See Table 5-1) Setting up the Transmit Character Buffer Length The Transmit character buffer length is the number of characters that the JDC can receive in its transmit buffer from the DeviceNet system. This size value also determines the maximum size of the poll command to the JDC from the Master (which is the JDC s Consume Size) and is determined by: consume_size = transmit_character_length + 2 The valid settings for this value are The default value is 20 (14 hex ). This consume_size is used to set up the Poll transmit (command) size at your Master device. These values can be set and retrieved by using the standard set and get services on class 15 (F hex ), instance 6, attribute 1 (See Table 5-1) Setting up the Pad Mode Pad Mode operation is the method by which the JDC adds extra characters to the end of its received data string (after the delimiter char) from the external ASCII device before sending the string to the DeviceNet scanner (Master) as an I/O Response. The quantity added is such that the data string returned to the scanner is always a constant length, and that length is the number specified in the receive_character_length parameter plus 3. The quantity of pad characters sent can vary from message to message, depending upon the size of the incoming string. Pad mode is included with our device for compatibility with scanners that to not fully conform to the ODVA specification for receiving variable length I/O messages. (Notable examples include many Allen-Bradley s scanners at the time of printing). For scanners with this restriction, you must turn ON Pad mode (a value of 1). Turning Pad mode on will not harm ODVA compliant scanners; thus the default value for pad mode is OFF. If your scanner supports variable I/O messaging lengths, you may turn off pad mode off (a value of 0) to conserve some network bandwidth. 21

23 The selection of Pad Mode is valid only for the ASCII receive and DeviceNet I/O Response operation. It has no effect on DeviceNet I/O Command strings and ASCII transmit data to your ASCII device. These values can be set and retrieved by using the standard set and get services on class 15 (F hex ), instance 8, attribute 1 (See Table 5-1) Setting up the Pad Character The JDC allows you to specify the character that pad mode uses to pad the received serial data with. This can be set to any valid ASCII value (0-127 in 7 bit modes, in 8 bit modes). These values can be set and retrieved by using the standard set and get services on class 15 (F hex ), instance 9, attribute 1 (See Table 5-1) Using the Swap Bytes Mode This mode is used if it is necessary to communicate through DeviceNet to an Allen Bradley PLC, such as the SLC500. When a serial message is to be transmitted or received, the bytes of the message will be reversed on the word boundary. Thus the message ABCD will be in memory like BADC. This may cause problems in some cases. By setting Parameter 10 (class F hex, instance 10, attribute 1) to 1, the bytes will be swapped by the JDC for both transmit and receive. This means that all messages retain their left to right byte sequence in memory. For this to work, you must specify an even length for parameters 5 and 6. Messages may be any length (odd or even) that are equal to or less than parameters 5 or 6. When transmitting out from the PLC, the size of the string transmitted should be an even number. When transmitting an odd size, round up the size to the next even number. By setting Parameter 10 to 2, the bytes will be swapped in 4 byte blocks (32-bits) for both transmit and receive, achieving the same left to right sequence as above in the 32 bit memory. This mode is intended for use with AB 32-bit PLC s. For this to work, you must specify a length that is evenly divisible by 4 for parameters 5 and 6. Messages may be any length (odd or even) that are equal to or less than parameters 5 or 6. When transmitting out from the PLC, the size of the string transmitted should be an even number. When transmitting an odd size, round up the size to the next divisible by 4 number. Example: The length of the message is 16 bytes. Add 2 since we are using carriage return / linefeed terminators. Since 4 doesn t divide into 18 evenly, the length should be specified as 20. Note: When mapping the JDC into a PLC and using byte swapping, be sure the message body starts on a 16 or 32 bit boundary or the results may be erroneous. It usually means mapping the record number, error (if receiving), and length bytes to the discrete input or output file or another suitable data file. This is also helpful, since the values of these numbers are available for use without a copy file command, such as needed when dealing with M0 and M1 files. The body of the ASCII string can be mapped to the M0 and M1 files. Note: This feature is only valid for non-zero length strings (non-character-terminated data). It will not work with character-terminated strings when the length byte is left at 0. Note: Termination characters are counted as part of the length of the non-zero length strings. Note: The Pad mode should be used when operating a JDC with a PLC master. 22

24 Transmitting Serial Data The use of a delimiter in transmitting data to a serial device from the JDC is determined by the Max_Number_of_Transmit_Chars parameter. The operation is defined below. If Max_Number_of_Transmit_Chars = 0 (Param. 5), The JDC receives data sent from the DeviceNet Master and uses the delimiter to determine how much data is sent to the serial device. If a delimiter is contained within the string, then all characters up to and including the defined delimiter are sent to the ASCII device If no delimiter is contained within the string, then the JDC will send data received from the DeviceNet I/O command message to the ASCII device Note: If Max_Number_of_Transmit_Chars is zero, Byte-Swapping will not work. If Max_Number_of_Transmit_Chars > 0 (Param. 5), The JDC receives data sent from the DeviceNet Master ignoring any embedded terminator. It will send the number of characters defined in Max_Number_of_Transmit_Chars, or the total sent by the Master, whichever is less. Note: Pad Mode is irrelevant to the ASCII transmit operation ASCII Receive Data and Pad Mode The selection of Pad Mode is valid only for the ASCII receive and DeviceNet I/O Response operation. It has no effect on DeviceNet I/O Command strings and ASCII transmit data to your ASCII device. The number of bytes returned to the DeviceNet Master in a Poll Response is as follows: If Max_Number_of_Receive_Chars = 0 (Param. 5), The expected operation is that the JDC receives characters (data bytes) until the delimiter character is received If a delimiter is received, then all characters up to and including the defined delimiter are sent to the DeviceNet master If no delimiter is received, then the JDC will receive data until the quantity of received bytes fills up its internal buffer (124 bytes), and then sends the entire string to DeviceNet with an overflow error In this situation, the Pad Mode selection is irrelevant and no pad characters are added to the data returned. Note: If Max_Number_of_Receive_Chars is zero, Byte-Swapping will not work. 23

25 If Max_Number_of_Receive_Chars > 0 (Param. 5), The expected operation is that the JDC receives characters (data bytes) until the delimiter character is received If a delimiter is received, then All characters up to and including the defined delimiter are sent to the DeviceNet master, and o o If Pad Mode = 1, then the JDC will fill the Poll Response data with the Pad Char defined in Param. 9, up to the defined size If Pad Mode = 0, then the JDC will send only the data up to and including the delimiter If no delimiter is received, then The JDC will receive up to Max_Number_of_Receive_Chars, and then sends this string to DeviceNet with an overflow error If will continue to receive and send strings of size Max_Number_of_Receive_Chars, along with the overflow error, until a delimiter is received. This could continue indefinitely if your ASCII device does not transmit the specified delimiter. 5.2 Setting up DeviceNet Communications The 1782-JDC supports 3 modes of data transfer of the serial buffer. They are: Polled Change-of-state Cyclic Polled I/O The polled connection is the only manner in which you can send serial output data to the JDC and, therefore, to your ASCII device. The DeviceNet Master initiates the polled connection transfer. The Master sends the JDC its serial output buffer along with a record number and length byte. The JDC monitors for a change in the record number. If the record number changes, then the 1782-JDC transmits the data buffer on its serial link. If the record number does not change, then the device does not transmit the data buffer. After the device has transmitted its data out to the serial link, the JDC then takes any information that is stored in its current serial input buffer and sends this data to the DeviceNet Master. It sends all characters up to and including the received delimiter, padding only if specified in the parameter object. When the JDC receives a new message (either with a delimiter or with an overflow condition without a delimiter) the device then increments the receive record, updates the length byte, and copies the new information from the last receive delimiter into the buffer. If an overflow occurs, the JDC indicates so in its receive status bit. The receive status byte also reflects parity errors in the device. (See Table 2-3.) Cyclic and Change-of-State I/O The Cyclic connection initiates a transmission every time the connection timer expires. This is explained below in the Section The cyclic connection can only send data from 24

26 the JDC. If you need to transmit on the ASCII link, you will need to use the polled connection to do so. The polled and cyclic connections are not exclusive, so both can exist at the same time. The manner in which cyclic connection reports its data is the same as the polled connection. The cyclic connections transmit buffer is the same as the polled connections transmit buffer, so overflows and received delimiters act the same over any connection. The Change of State (COS) connection is the same as the cyclic connection except that as well as triggering communications on the expiration of the timer, the COS connection also initiates a transfer on a receive of the delimiter or an overflow. The COS connection is mutually exclusive with the cyclic connection, but can coexist with the polled connection. The COS connection operation is very useful in conserving bandwidth, and provides the Master with the most current data as fast or faster than a poll connection. The COS connection automatically turns on the COS mechanism when the connection is created Setting up the DeviceNet I/O Connections It is useful to first set up your serial link before setting up your connection. To set up the communications with your network configuration tool, it is often necessary to know the connection input and output sizes. Instructions for setting up your serial connection are provided above. See the sections on receive and transmit sizes. If you are using a network configuration tool with some type of scanner or scanning software, you must direct your scanner to set up the connections for you. This often requires some information about the device, such as input and output sizes. The input and output sizes are computed from the transmit size and the receive sizes. These sizes are defined in the parameter object of your device. The transmit size of the poll connection is computed by adding 2 to the transmit buffer size on the 1782-JDC. The Transmit size for the change of state and cyclic connections are set to 0, because these connections do not initiate a transmission on the serial link. The receive size of all three connections is computed by adding 3 to the receive buffer size. Important: Remember to re-map the data (if necessary) after you set the sizes, because many configuration tools will automatically unmap your data when you change the connection sizes. If you are not using such a software package, it is probably not necessary to set up the transmit and receive sizes Setting up the Connection Timer (EPR) EPR stands for Expected Packet Rate. This is the value that the JDC sets the connection timer to for the cyclic and polled connection. This is also the value it uses in the connections to calculate the time the device should wait before signaling a timeout. If you have a scanner or scanning software, you must configure it with the EPR that you want the JDC to be scanned with. The scanner will then configure the EPR in the JDC at the beginning of communications. Consult your scanner s manuals on how to configure the EPR (the EPR is sometimes referred to as the scan rate ). Note: If you need to set up the EPR, it can be done manually by performing a set (Service 10 hex ) on the connection class (Class 5 hex ) attribute 9. The polled connection uses instance 2, where as the COS and cyclic connections use instance 4. This must be done after allocating the connection Autobaud Operation Autobaud is the mechanism that allows the DeviceNet device, in this case the JDC, to automatically determine the baud rate that is operational on the network to which the JDC is connected and adjust its DeviceNet speed to match. The JDC is shipped with autobaud as its 25

27 default baud rate Setting up the DeviceNet Baud rate If you wish to change the baud rate to a fixed speed, you can set it in two different places. The first is the standard location for the DeviceNet baud rate, which is in the DeviceNet object. This is where most configuration tools will look to change the baud rate. This is fine on normal DeviceNet systems, however the JDC provides some extended DeviceNet functionality above normal systems to allow the autobaud functionality. This extension is not defined by ODVA thus cannot be attached to any of the standard DeviceNet objects to ensure compatibility. You can still use the baud rate in the normal manner; it will just not allow the autobaud setting. We have provided an extended baud rate parameter at attribute 7 of the parameter object to allow for the autobaud baud rate setting. (See Table 5-1). These values can be set and retrieved by using the standard set and get services on class 15 (F hex ), instance 7, attribute 1. (See Table 5-1). 26

28 A. DeviceNet Profile, Objects and Services A JDC DeviceNet Profile This section describes the DeviceNet Objects present in the JDC. The JDC conforms to a Type 12, Communications Adapter Device. Object Table A-1 DeviceNet Objects DeviceNet Object Class # of Instances Identity 1 1 Message Router 2 1 DeviceNet 3 1 Connection 5 3 (Explicit Msg., Polled I/O, COS/Cyclic) Parameter 15 (F hex ) 10 27

29 A.2 Serial I/O Polled Data Formats Table A-2 Poll Produce Data (ASCII Receive String) Byte Character Description 0 Record # Record Counter, Integer value = Initialized State (counter value rolls over from 255 to 1, skipping 0) 1 Status Status / Error Value 2 Length Length of valid data in bytes 3 1 st Char ASCII Character 4 2 nd Char ASCII Character length+1 Last Char ASCII Character length+2 terminator End-of-Text Character Max Rec. Char + 2 Any Pad character (present if characters received is less than Max Receive Chars value) Table A-3 Poll Consume Data (ASCII Transmit String) Byte Character Description 0 Record # Record Counter, Integer value = Initialized State (counter value rolls over from 255 to 1, skipping 0) 1 Length Number of bytes to transmit. 0 indicates transmit delimited mode, in which the device transmits up to and including the transmit delimiter character defined in the parameter object. 2 1 st Char ASCII Character 3 2 nd Char ASCII Character 4 3 rd Char ASCII Character length Last Char ASCII Character length +1 Terminator End-of-Text Character Max TX Any Undefined Length 1 Max TX Length Any Undefined (last char in this record transmitted to Master) 28

30 A.3 Identity Object, Class 1 Instances 0 and 1 exist in the 1782-JDC. Table A-4 Identity Object Class Attributes (Instance 0) Attribute Access DeviceNet Name Description of Attribute Value ID Rule Data Type 1 Get Revision UINT Revision of this object 1 Max. Object Maximum instance number of an 2 Get UINT 1 Instance object currently Max. Class Attribute ID number of the last class 6 Get Attribute ID UINT attribute of the class definition 7 7 Get Max. Instance Attributes ID UINT implemented in the device Attribute ID number of the last instance attribute of the class definition implemented in the device 1 Attribute ID Access Rule Table A-5 Identity Object Instance Attributes (Instance 1) Name DeviceNet Data Type Description of Attribute Value 1 Get Vendor UINT ODVA Vendor Number for this product 9 = WRC 2 Get Device 12 = Comm. UINT ODVA Communications Device Type Type Adapter 3 Set Product Code UINT WRC Unique Product Code Number 701 = 2bd hex 4 Get Revision STRUCT of: Revision of this device Major Revision USINT >=5 Minor Revision USINT >=1 5 Get Status WORD Summary status of device 6 Get Serial Number UDINT WRC Unique Device Serial Number 7 Get Product SHORT_STRI Name NG ASCII Name of product 1782-JDC 10 Get/Set Heartbeat Interval USINT The interval in second that the device generates a heartbeat message. A value of 0 disables heartbeat generation. 0 Table A-6 Identity Object Common Services Service Code Class Instance Service Name Description of Service O5 hex Yes Yes Reset Invokes the Reset Service for the device. OE hex Yes Yes Get_Attribute_Single Returns the contents of the specified attribute. 10 hex No Yes Set_Attribute_Single Modifies an attribute value. 29

31 A.4 Parameter Object, Class Fhex (15dec) There are many configurable data parameters associated with your JDC. The JDC uses a Parameter Object (a collection of these parameters) to assist you in reading and changing configurable data. Following are the Class Attributes, Instance Attributes and Services that are supported by the JDC for the Parameter Object. Table A-7 Parameter Class Attributes (Instance 0) Attribute Access DeviceNet Name Description of Attribute Value ID Rule Data Type 1 Get Revision UINT Revision of this object. 1 Max. Maximum instance number of 2 Get UINT 9 Instance the Parameter object 8 Get Parameter class descriptor WORD Bits that describe parameters. 9 (supports parameter instances, params are stored in non-volatile memory) Attribute ID Access Rule 1 Set 2 Set Table A-8 Parameter Instance Attributes (Instances 1-7) Name DeviceNet Data Type Description of Attribute Value Parameter Value Link Path Size 3 Set Link Path data type specified in Descriptor Data Type and Data Size. USINT ARRAY of DeviceNet path: Actual value of parameter. It can be read from or written to. This attribute is read-only if bit 4 of Attribute 4 is TRUE. Size of link path. If this is 0, then no link is specified. DeviceNet path to the object from where this parameter s value is retrieved. 4 Get Descriptor WORD Description of parameter. 5 Get Data Type USINT Data type code. 6 Get Data Size USINT Number of bytes in Parameter Value Number of bytes Table A-9 Parameter Common Services Service Code Class Instance Service Name Description of Service O5 hex Yes N/A Reset Resets all parameters to out-of-the-box values. OE hex Yes Yes Get_Attribute_Single Returns the contents of the specified attribute. 10 hex Yes Yes Set_Attribute_Single Modifies an attribute value. 30

32 Table A-10 JDC Parameter Instances (Class F hex ) Parameter Param. Instance Description Parameter Choices Default Setting Default Value Serial Character Format Serial Baud Rate 1 Character framing 2 RS232/ RS422/RS485 communications speed 0 = 7N2 1 = 7E1 2 = 7O1 0 = = = = 8N1 4 = 8N2 5 = 8E1 6 = 8O1 3 = = 19.2k 5 = 38.4k 7N baud 0 Receive Delimiter 3 Character which identifies the end of the data string from the ASCII device when the length is specified as 0 Any valid standard ASCII character (0 127, 0-255) Carriage return D hex Transmit Delimiter 4 Character which identifies the end of the transmit data string to the ASCII device when the length is specified as 0 Any valid standard ASCII character (0 127, 0-255) Carriage return D hex Max Number of Receive Chars 5 Maximum number of characters the JDC expects to receive into its ASCII port from the serial device characters 14 hex Max Number of Transmit Chars 6 Maximum number of characters the JDC expects to transmit out its serial port to the serial device characters 14 hex Device Net Baud Rate 7 The baud Rate of the device net device. The baud rate can be set here and will take effect once the JDC has been reset. 0 = 125 Kbaud 1 = 250 Kbaud 2 = 500 Kbaud 3 = Autobaud Autobaud 3 Pad Mode 8 Indicates whether to pad the invalid data region after the delimiter with the pad character, or to use variable length I/O responses 0 = Pad Mode Off 1= Pad Mode Enabled Enabled 1 Pad Character 9 The value to use to pad the invalid data portion of the poll response Any valid standard ASCII character (0 127, 0-255) NULL 0 Swap Bytes 10 If enabled, the position of the bytes in the serial messages will be swapped every 2 or 4 bytes. 0 = Disabled 1 = 16-bit Swap Enabled 2 = 32-bit Swap Enabled Disabled 0 31

33 Parameter Instances for Table A Serial Character Format: The character frame format. 2. Baud Rate: The baud rate of the ASCII channels. Valid baud rates are 1200, 2400, 4800, 9600, 19.2k, and 38.4k baud. 3. End-of-Text Character: The (printable or non-printable) byte character (value of 0-255) that signifies that the last character in a string of ASCII characters has been reached. The JDB will not return to the Master any additional characters after the EOT character, or any characters in the string after the maximum character count is reached. 4. Transmit Delimiter: The (printable or non-printable) byte character (value of 0-255) that signifies that the last character in a string of ASCII characters has been reached. The JDB will not transmit to the device any additional characters after the transmit delimiter character, or any characters in the string after the maximum character count is reached. 5. Maximum Number of ASCII Input Characters: The maximum number of ASCII characters expected to be input from the serial device connected to this port. The end-of-string, or endof-text, character is included in this count. (A 0 implies the port does not receive data from the external device or that no device exists.) 6. Maximum Number of ASCII Output Characters: The maximum number of ASCII characters that will be sent from the host to the serial device connected to this port. The end-of-string, or end-of-text, character is included in this count. (A 0 implies the port does not output data to the external device or that no device exists.) 7. DeviceNet Baud Rate: Allows a selection of baud rates on the DeviceNet link. 8. Pad Mode: When enabled the pad mode will pad the serial receive data with the specified pad character. When disabled, the JDC will only return the receive data, saving some network bandwidth. The default is enabled. Pad mode must be enabled for Allen-Bradley Scanners due to their inability to handle short poll responses. 9. Pad Character: The character that the pad mode uses to lengthen the poll response with. 10. Swap Bytes: Exchange byte positions on word or long integer boundaries for both receive and transmitted messages. This is included for capability with Allen Bradley PLC s such as the SLC500 or Control Logic. 32

34 A.5 Common DeviceNet services The common DeviceNet services are available through many of the common configuration tools. However, each configuration tool may implement these differently. It may be easier if you use this section in conjunction with any files or documentation that was included with your DeviceNet configuration tools while going over this section. DeviceNet is divided into logical functional blocks called objects, which provide services that allow for control over the hardware and routines that those objects contain. To allow for multiple similar functions, the objects are built of multiple instances that the services of the objects act upon. A class service acts upon the entire object, allowing one service to be enacted on all of the instances. This saves time, effort and network bandwidth. The common services are a common set of services that have been provided in most or all of the objects to allow for common functionality in creating, deleting, getting, setting and resetting the variables of the different classes and instances. We will describe two of the services here: get and set. The get and set services have a common format for specifying what object, instance, attribute and service that the command is specifying. In order of first to last, DeviceNet specifies service, class, instance, attribute and data. The data is always little-endian (low byte precedes high order byte), and the others are all one byte in length on the JDC. Note that the get service has no data. The get service gets data from an attribute of a class or class instance. The service number of this request is 14 (E hex ). The class instance and attribute are all defined by which variable you want to get. The response from a get command takes on the form: service, value. The value will be little-endian and can be of variable length and bounds based on the definition of the attribute. The service will be reported as the get service with the highest bit set to indicate a response. The set service sets data from an attribute of a class or class instance. The service number of this request is 16 (10 hex ). The class instance and attribute are all defined by which variable you want to set. The value is little endian, and the size is defined by the attribute that you are setting. The response from a set command only echoes the service. The service will be reported as the set service with the highest bit set to indicate a response. An error response will have the service set to 94 hex. This response will be followed by a twobyte error code, defining the type of fault. For a detailed list of error codes, connect to the ODVA web site at 33

35 B. Accessories and Other WRC Products The following components can be used with a JDC for replacements or spare parts, or as complementary devices as a part of your DeviceNet or other CAN-Bus system. Table B-1 WRC Replacements, Spare Parts and Other Products Part WRC Part Number DIN rail WRC Terminating resistor, axial lead Discrete I/O block 4 channels Discrete I/O block 8 channels Analog Input block 4 channels, 10-bit Analog I/O block 8 channels, 12-bit DeviceNet to Serial I/O Gateway DeviceNet to Modbus Gateway DeviceNet to Optomux Gateway DeviceNet to Pamux Gateway DeviceNet to Serial Gateway, open frame DeviceNet/CAN Software Utility Discrete I/O block 24 channels Discrete I/O block 48 channels Discrete I/O, Analog Input block 24 DIO, 32 AI Discrete I/O, Analog Input block 48 DIO, 32 AI Analog I/O block - 32 channels Discrete and Analog I/O block 24 DIO, 32 AIO Discrete and Analog I/O block 48IO, 32 AIO Discrete I/O block 8 DIs, 8 DOs, 4 AIs DeviceNet, CANopen Extender, DIN mount DeviceNet, CANopen Extender, DIN mount DeviceNet, CANopen Extender, NEMA box DeviceNet, CANopen Extender, NEMA box DeviceNet, CANopen Extender, Fiber Optic, NEMA box, multi-mode fiber DeviceNet, CANopen Extender, Fiber Optic, NEMA box, single-mode fiber RM121DN 1782-JDB JDB JDA JDA JDC 1782-JDM 1782-JDO 1782-JDP 1799wr-DASCII DNspector W2-JDB24 W2-JDB48 W2-JDA24 W2-JDA48 W2-JDAIO W2-JDAIO24 W2-JDAIO48 W5-JDB16x WRC-CANX-DIN-DN WRC-CANX-DIN-C7 WRC-CANX-NEM-AU WRC-CANX-NEM-DN WRC-CANR-DF-DN WRC-CANR-DF-SM 34

36 C. Frequently Asked Questions 1. Where are the 1782-JDCx gateway User s Manuals located? The WRC product User s Manuals are available from our web site Support -> Technical Data 2. What are the 1782-JDCx gateways and why should I consider purchasing one for my DeviceNet network? The 1782-JDCx gateways are communications adapter devices that provide you with a flexible DeviceNet interface to a wide variety of ASCII devices. The JDCx models allow you to easily and conveniently connect and integrate peripheral products with either RS-232, RS-485 or RS-422 serial ports into a DeviceNet system, enabling you to select just the right peripheral device for your application without limiting your selection to DeviceNet-cable devices only. 3. How can I change the DeviceNet MAC ID of my 1782-JDCx? The address of the 1782-JDCx will come preset from the factory for address 63. You may change the address using the bank of 6 DIP switches on the unit: they can be set to any address from 0 to 63 in binary (111111=address 63). The MACID or address will not change if the switches are moved while the device is powered; power must be removed and reapplied when a new switch setting and MAC ID are desired or a device reset command must be issued. 4. What electrical connections are required for a 1782-JDCx gateway? DeviceNet Cable Connection: 1, 5-pin pluggable header (male, Phoenix Contact MSTBA 2.5/5-G-5.08/AU or equivalent) Serial Cable Connection: For RS-232 & RS-485 1, 3-pin pluggable header (male, Phoenix Contact MSTBA 2.5/3-G-5.08/AU or equivalent) Serial Cable Connection: For RS-422 1, 5-pin pluggable header (male, Phoenix Contact MSTBA 2.5/5-G-5.08/AU or equivalent) 5. How do I begin to use a 1782-JDCx gateway? You can begin to use a 1782-JDCx gateway by following the User s Manual Quick Start instructions. 6. What are the LEDs on the 1782-JDCx indicating? There are two sets of LEDs on the unit. The two green LEDs next to the serial connector are used as indicators for activity on the serial communication receive and transmit ports. The other two bi-color LEDs are used to indicate the DeviceNet module (MS) and network (NS) status. For troubleshooting or further information on status definitions corresponding to LED actions see LED Operation in the 1782-JDCx User s Manual. 7. On what DIN rail can I mount the 1782-JDCx? The 1782-JDCx can be mounted on DIN rail mount EN50022 (WRC50022). 8. What are some common applications for the 1782-JDCx gateway? A 1782-JDCx gateway provides DeviceNet communications for weigh scales, bar code readers and scanners, display panels, robots, drives, operator stations / HMI, magnetic code readers and other ASCII serial devices. 9. Are the 1782-JDCx gateways designed to plug-n-play? Yes, the 1782-JDCx gateways are designed to plug-n-play using our factory default settings: serial framing of 7N2, serial baudrate of 9600, max number of receive and transmit 35

37 characters set to 20, pad mode off, etc. The full list of default settings can be found under Default Settings in the User s Manual. If you wish to change any parameters from their default settings you will need to use a DeviceNet software configuration tool. Many of these tools have EDS readers, which make the editing process easier. 10. Does a 1782-JDCx gateway provide electrical isolation? Yes, a 1782-JDCx gateway provides 1000V network electrical isolation. 11. What are the currently available 1782-JDC-x gateway models? 1782-JDC-1: Isolated RS232 Interface 1782-JDC-2: Isolated RS485 Interface 1782-JDC-4: Isolated RS485/RS422 Interface 1782-JDCE-1: Isolated RS232 Interface with Enhanced Parameters 12. On what DeviceNet baud rates does the 1782-JDCx communicate? The unit works with 125k, 250k or 500k baud rates. It is default set to autobaud on DeviceNet. A fixed baud rate of 125k, 250k or 500k may also be assigned with a software configuration tool. 13. On what baud rates does the serial port communicate? The serial port on the 1782-JDCx will communicate on baud rates of: 1200, 2400, 4800, 9600, 19.2k, or 38.4k baud. 14. How do I connect a 1782-JDCx gateway to a serial port device? You connect the JDCx to a serial port device with the Phoenix connectors on the unit which are labeled for which signal goes in each port of the connector. For RS-232 or RS-485 communications the signal/pin assignments are as follows: For RS-422 or RS-485 communications the signal/pin assignments are as follows: Pin # Designator RS422 RS485 (RS422/RS485) Signal Signal 5 TX- / GND Transmit - no connection 4 TX+ / GND Transmit + no connection 3 GND / GND Ground Shield 2 RX- / SG- Receive - Signal - 1 RX+ / SG+ Receive + Signal How is the Master Handshake mode different from the Hardware handshake RTS/CTS? Master Handshake mode is a data control mechanism between the DeviceNet master and the 1782-JDCx (after the JDCx receives data from serial device), communicated in IO message. The 1782-JDCx indicates new data arrival and waits for Master to issue a new record number, to be used with new data. The hardware handshaking via RTS/CTS (which 36

1782-JDC DeviceNet/Serial Gateway User s Manual

1782-JDC DeviceNet/Serial Gateway User s Manual 1782-JDC DeviceNet/Serial Gateway User s Manual Western Reserve Controls, Inc. Although every effort has been made to insure the accuracy of this document, all information is subject to change without

More information

1782-JDO DeviceNet-to-Optomux Gateway User s Manual

1782-JDO DeviceNet-to-Optomux Gateway User s Manual 1782-JDO DeviceNet-to-Optomux Gateway User s Manual Western Reserve Controls, Inc. Although every effort has been made to insure the accuracy of this document, all information is subject to change without

More information

Products for DeviceNet

Products for DeviceNet Four-port DeviceNet Gateways W5-JDC4 The W5-JDC4 is a DeviceNet-to-serial link communications gateway that provides a flexible DeviceNet interface to as many as four different channels of ASCII devices.

More information

Products for DeviceNet

Products for DeviceNet Four-port DeviceNet Gateways WRC is one of the original members of ODVA Your source for Blue-Collar Electronics. W5-JDC4 The W5-JDC4 is a DeviceNet-to-serial link communications gateway that provides a

More information

WRC-CANX CAN Bus Extender, Version 2 User s Manual

WRC-CANX CAN Bus Extender, Version 2 User s Manual WRC-CANX CAN Bus Extender, Version 2 User s Manual Western Reserve Controls, Inc. Although every effort has been made to insure the accuracy of this document, all information is subject to change without

More information

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison DNETEXT-C CAN Bus Extender, Version 3 User s Manual Brad Harrison Although every effort has been made to insure the accuracy of this document, all information is subject to change without notice. Woodhead

More information

1782-JDA8 SmartMux-Lite / DeviceNet User s Manual

1782-JDA8 SmartMux-Lite / DeviceNet User s Manual 1782-JDA8 SmartMux-Lite / DeviceNet User s Manual Western Reserve Controls, Inc. Although every effort has been made to insure the accuracy of this document, all information is subject to change without

More information

WRC-CANR-DF-DN Series 3 CAN-Bus Fiber Optic Bus Extender User s Manual

WRC-CANR-DF-DN Series 3 CAN-Bus Fiber Optic Bus Extender User s Manual WRC-CANR-DF-DN Series 3 CAN-Bus Fiber Optic Bus Extender User s Manual Western Reserve Controls, Inc. Although every effort has been made to insure the accuracy of this document, all information is subject

More information

CDN067 DEVICENET SPECIFICATIONS

CDN067 DEVICENET SPECIFICATIONS CDN067 DEVICENET SPECIFICATIONS Revision History Revision Description Date 1.0 Initial Release Upgrade to DNet Rev. 2.0 07/20/98 Added support for status byte and status clear in poll Disallowed changing

More information

DN120 DeviceNet Gateway User Manual

DN120 DeviceNet Gateway User Manual DN120 DeviceNet Gateway User Manual DN120 PN 84-210010 Rev A Table of Contents CHAPTER 1 OVERVIEW... 4 CHAPTER 2 INSTALLATION... 5 MOUNTING... 5 WIRING... 6 DeviceNet Interface... 6 Serial Channel Interface...

More information

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths

More information

DEFAULT IP ADDRESS

DEFAULT IP ADDRESS REAL TIME AUTOMATION 2825 N. Mayfair Rd. Suite 111 Wauwatosa, WI 53222 (414) 453-5100 www.rtaautomation.com EtherNet/IP - DeviceNet Master Gateway MODBUS TCP - DeviceNet Master Gateway Copyright 2007 Real

More information

2002 Series DeviceNet Technical Manual

2002 Series DeviceNet Technical Manual 2002 Series DeviceNet Technical Manual Table of Contents 2002 Series DeviceNet Technical Manual 2002 Introduction...4 Product Overview...4 About DeviceNet...5 Overview...5 2002 DeviceNet Features...5 Cabling

More information

L5351 DeviceNet Communications Interface

L5351 DeviceNet Communications Interface L5351 DeviceNet Communications Interface Technical Manual HG353798 Issue 2 Copyright SSD Drives, Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

MPCR Series DeviceNet Technical Manual

MPCR Series DeviceNet Technical Manual MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction...3 Product Overview...3 About DeviceNet...4 Overview...4 MPCR DeviceNet Features...4 Cabling and Drop Line Lengths (as

More information

DeviceNet INSTRUCTION MANUAL. Series 956. Resolver Displacement Transducer

DeviceNet INSTRUCTION MANUAL. Series 956. Resolver Displacement Transducer Series 956 INSTRUCTION MANUAL DeviceNet Resolver Displacement Transducer This manual covers 1986DN, 1980DN, 1990DN and 925DN units with built in resolvers. Spec Tech Industrial 203 Vest Ave. Valley Park,

More information

CDN572-5 DEVICENET SPECIFICATIONS

CDN572-5 DEVICENET SPECIFICATIONS CDN572-5 DEVICENET SPECIFICATIONS TABLE OF CONTENTS Revision History...v CDN572-5 Overview...1 Hardware...1 Processor...1 DeviceNet Interface...1 Power Distribution...2 Switches and Indicators...2 MacID/BaudRate...3

More information

X-gateway Interface Addendum DeviceNet Scanner Interface

X-gateway Interface Addendum DeviceNet Scanner Interface X-gateway Interface Addendum DeviceNet Scanner Interface Rev. 1.10 HMS Industrial Networks AB Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 ge-sales@hms-networks.com

More information

CDN36X Series DeviceNet Gateway User Manual

CDN36X Series DeviceNet Gateway User Manual CDN36X Series DeviceNet Gateway User Manual CDN366 1 isolated RS232 channel CDN367 1 isolated RS422/RS485 channel Table of Contents CHAPTER 1 OVERVIEW...4 CHAPTER 2 INSTALLATION...5 MOUNTING...5 WIRING...6

More information

DeviceNet Expansion Board

DeviceNet Expansion Board DeviceNet Expansion Board Catalog No. EXBD05 Installation and Operating Manual 10/02 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

Powered Roller Controller for DeviceNet

Powered Roller Controller for DeviceNet PRC-620-090 TECHNICAL DATA Description The Holjeron Powered Roller Controller for use with DeviceNet has the features needed to handle up to four zones in a material handling system. A Brushless DC Powered

More information

G3 Series DeviceNet TM Technical Manual

G3 Series DeviceNet TM Technical Manual G3 Series DeviceNet TM Technical Manual Table of Contents G3 Series DeviceNet Technical Manual PAGE About DeviceNet... 3 Overview... 3 G3 DeviceNet Features... 3 Cabling and Drop Line Lengths (as defined

More information

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB BridgeWay PROFIBUS to DeviceNet Gateway User Manual Part No. AB7605 Pyramid Solutions 1850 Research Drive, Suite 300 Troy, Michigan 48083 Phone 248-524-3890 Web www.pyramid-solutions.com Publication PUB-AB7605-005

More information

M3-61B DeviceNet Slave Module. M3-61B DeviceNet Slave Module CONTROL TECHNOLOGY CORPORATION

M3-61B DeviceNet Slave Module. M3-61B DeviceNet Slave Module CONTROL TECHNOLOGY CORPORATION CONTROL TECHNOLOGY CORPORATION M3-61B DeviceNet Slave Module M3-61B DeviceNet Slave Module Copyright 2008-2010 Control Technology Corporation All Rights Reserved. Blank Control Technology Corporation 2

More information

Preface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1

Preface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1 Preface Thank you for purchasing the Pro-face LogiTouch Type-D DeviceNet master unit. The LogiTouch Type-D (also referred to as the LT Type-D ) allows connection to the DeviceNet Fieldbus to access many

More information

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01 ABB Drives User s Manual DeviceNet Adapter Module RDNA-01 DeviceNet Adapter Module RDNA-01 User s Manual 3AFE64504223 REV C EN EFFECTIVE: 16.11.2006 2006 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

DNP31.0 DeviceNet Interface

DNP31.0 DeviceNet Interface Technical description DNP31.0 DeviceNet Interface Data sheet Description The DNP31 devcie allows the connection of the Universal Motor Controller UMC100.3 to a DeviceNet network. Please note the following

More information

X-gateway Interface Addendum DeviceNet Scanner

X-gateway Interface Addendum DeviceNet Scanner X-gateway Interface Addendum DeviceNet Scanner Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing address: Box 4126,

More information

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents Section 1.0 Description... 2 Section 2.0 Installation 2.1 Soft starter to gateway connection... 3 2.2 Soft starter configuration... 3 2.3 Gateway to DeviceNet connection... 3 2.4 Gateway configuration...

More information

CDN127 DeviceNet SPECIFICATIONS

CDN127 DeviceNet SPECIFICATIONS CDN127 DeviceNet SPECIFICATIONS Revision 1.6 04/01/01 Table of Contents Revision History...v Overview...1 Device Description...1 Switches...1 Indicators...2 Internal Jumpers...3 DeviceNet Interface...3

More information

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check Product Description Revision Letter: BA Firmware version: 1.10 Firmware upgrades: DeviceNet Certification: Product Name: None Certificate available upon request. DeviceNet Network Control Module (NCM)

More information

Allen-Bradley Automation

Allen-Bradley Automation Product Data 1791D CompactBlock I/O for DeviceNet 1791D CompactBlock I/O modules contain I/O circuits, a built-in power supply, and a built-in DeviceNet I/O adapter. CompactBlock I/O modules are ideal

More information

DeviceNet (CME-DN01) User Manual

DeviceNet (CME-DN01) User Manual DeviceNet (CME-DN01) User Manual DeviceNet is a trademark of the Open DeviceNet Vendor Association, Inc. The information supplied by this document is subject to change without notice. No responsibility

More information

Series SD6 Limit with DeviceNet

Series SD6 Limit with DeviceNet Series SD6 Limit with DeviceNet DeviceNet Communications This appendix describes the DeviceNet protocol as it is implemented in the Series SD6 controller. It primarily describes the objects and attributes

More information

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block USER S MANUAL FX2N-64DNET DeviceNet Interface Block FX2N-64DNET DeviceNet Interface Block Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation

More information

POINT I/O ASCII Modules

POINT I/O ASCII Modules POINT I/O ASCII Modules 1734-232ASC, 1734-485ASC User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application

More information

GSE Scale Systems A div of SPX Corporation

GSE Scale Systems A div of SPX Corporation GSE Scale Systems A div of SPX Corporation GSE 60-Series Instruments DeviceNet Communications Option And Application Note Ver 1.0.2 8/24/04 P/N 39-10-38883 Published by GSE Scale Systems 42860 Nine Mile

More information

D485 Modbus to DeviceNet Converter Instruction Manual

D485 Modbus to DeviceNet Converter Instruction Manual GE Consumer & Industrial D485 Modbus to DeviceNet Converter Instruction Manual Manual P/N: 1601-0235-A1 Manual Order Code: GEK-113195 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue, Markham,

More information

MicroNode I/O TM DeviceNet AI User Manual

MicroNode I/O TM DeviceNet AI User Manual MicroNode I/O TM DeviceNet AI User Manual Control & Information Technology Group 134 W Rio Robles Drive San Jose, CA 95134 Main: 408.750.0300 Fax: 408.750.2990 Rev. 03 11/05 Page 1 of 27 Copyright This

More information

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2

More information

DN-01 Instruction Manual

DN-01 Instruction Manual DN-01 Instruction Manual DeviceNet communication expansion board V 1.00 This instruction manual is only for the Shihlin communication expansion board DN-01. Please refer to ODVA DeviceNet specification

More information

DeviceNet SDNL-0404D-xxxx. IO Data Mapping DeviceNet Objects Indicators and Switches

DeviceNet SDNL-0404D-xxxx. IO Data Mapping DeviceNet Objects Indicators and Switches DeviceNet SDNL-0404D-xxxx IO Data Mapping DeviceNet Objects Indicators and Switches Version: 1.1 12.07.2002 SDNL-0404D-xxxx 3 Please note the following Target group Safety requirements This description

More information

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment. Installation OPERATING INSTRUCTIONS Order Code: 175G9002 Adjustment 35 mm (1.38 inches) Control power and mains supply must be removed from the MCD 200 before attachment or removal of an accessory module.

More information

SMARTLINX INTERFACE MODULE

SMARTLINX INTERFACE MODULE SMARTLINX INTERFACE MODULE FOR DEVICE NET Instruction Manual PL-583 April 2001 R 33455830 Rev. 1.1 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others,

More information

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01 ABB Drives User s Manual DeviceNet Adapter Module RDNA-01 DeviceNet Adapter Module RDNA-01 User s Manual 3AFE64504223 Rev D EN EFFECTIVE: 16.07.2007 2007 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

VLT 5000 DeviceNet and Allen Bradley Control logix 5550

VLT 5000 DeviceNet and Allen Bradley Control logix 5550 Foreword... 2 VLT 5000 DeviceNet card... 2 Configuring the VLT 5000 with RS Networx... 4 I/O communication with RS Logix 5000... 6 Explicit messages with RS Logix 5000... 8 1 Foreword This application

More information

VersaMax* DeviceNet Network Master/Slave

VersaMax* DeviceNet Network Master/Slave Product Description Quick Start Guide Revision: Firmware version: 1.10 Firmware upgrades: Specifications Operating Modes: Slaves Supported: Configuration: IC200BEM103-MA None Master only, Slave only, Combined

More information

BIDN. Vendor ID 133 BALOGH. Notes are used to call attention to information that is significant to the understanding and operation of equipment.

BIDN. Vendor ID 133 BALOGH. Notes are used to call attention to information that is significant to the understanding and operation of equipment. BIDN DeviceNet Interface Vendor ID 133 BALOGH Notes are used to call attention to information that is significant to the understanding and operation of equipment. This BALOGH manual is based on information

More information

VersaMax IP Input Module

VersaMax IP Input Module Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm

More information

FC 300 DeviceNet and Allen Bradley Control logix 5550

FC 300 DeviceNet and Allen Bradley Control logix 5550 Introduction... 2 FC 300 DeviceNet card... 2 Creation of an EDS file... 4 Configuring the FC 300 with RS Networx... 7 I/O communication with RS Logix 5000... 1 0 Explicit messages with RS Logix 5000...

More information

Elco BradControl DEVICENET ACTIVE 60mm Input/Output Interface Block May, 2008

Elco BradControl DEVICENET ACTIVE 60mm Input/Output Interface Block May, 2008 Elco BradControl DEVICENET ACTIVE 60mm Input/ Interface Block May, 2008 1. INTRODUCTION The following product numbers are covered by the information presented in this booklet: PART NUMBER BCDN-1600P-M12

More information

Series SD6 with DeviceNet (Addendum)

Series SD6 with DeviceNet (Addendum) Series SD6 with (Addendum) Watlow s Series SD6 with offers excellent control and application flexibly in a 1/16th DIN panel mount package. The Series SD6 with has been successfully tested for use with

More information

SMARTLINX INTERFACE MODULE

SMARTLINX INTERFACE MODULE SMARTLINX INTERFACE MODULE FOR DEVICE NET Instruction Manual December 2001 R Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product

More information

Install the DeviceNet Module using the following procedure:

Install the DeviceNet Module using the following procedure: Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from

More information

Installation Instructions for DeviceNet E50 Limit Switches

Installation Instructions for DeviceNet E50 Limit Switches Cutler-Hammer Installation Instructions for DeviceNet E50 Limit Switches DESCRIPTION General Information Network Media - DeviceNet Protocol - DeviceNet Rel 2.0 Type - Group 2 Only Slave Device using Predefined

More information

Installation Instructions

Installation Instructions Installation Instructions 1771-SDN/B DeviceNet Scanner Module Installation Instructions 1 (Catalog Number 1771-SDN/B) Use this document as a guide to installing your 1771-SDN/B Scanner Module. Before you

More information

WRC Modbus to DeviceNet Gateway for GPD 506/P5

WRC Modbus to DeviceNet Gateway for GPD 506/P5 Introduction This document describes the recommended method to configure and connect Western Reserve Controls (WRC) Modbus to DeviceNet gateway for use with the GPD 506/P5. There currently are three types

More information

GSE Scale Systems Ethernet IP Option

GSE Scale Systems Ethernet IP Option AN SPX BRAND GSE Scale Systems Ethernet IP Option Option P/N 24660B-421C0 Revision 0.51 Apr 3, 2008 Page 1 of 27 TABLE OF CONTENTS 1. INTRODUCTION...5 1.1 Overview...5 1.2 Definiti ons...5 1.3 Reference

More information

GW-7228 J1939/Modbus RTU Slave Gateway

GW-7228 J1939/Modbus RTU Slave Gateway GW-7228 J1939/Modbus RTU Slave Gateway User s Manual www.icpdas.com GW-7228 J1939/Modbus RTU Slave Gateway User s Manual (Ver 1.2, May/2011) ------------- 1 Warranty All products manufactured by ICP DAS

More information

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling MATERIAL HANDLING MANIFOLDS WITH DeviceNet INTERFACE 01348(N or G) MH** -- Material Handling 01351(N or G) MH** -- Material Handling Note: N = NPT ports G = BSPP ports SOL 14 SOL 12 Station #3 SOL 14 SOL

More information

User Manual for the HE693DNT750. DeviceNet Slave. Third Edition 22 June 2000 MAN

User Manual for the HE693DNT750. DeviceNet Slave. Third Edition 22 June 2000 MAN User Manual for the HE693DNT750 DeviceNet Slave Third Edition 22 June 2000 MAN0213-03 PREFACE 22 JUN 2000 PAGE 3 PREFACE This manual explains how to use the Horner APG s HE693DNT750 DeviceNet Slave. Copyright

More information

SE-330/SE-330AU/SE-330HV DEVICENET INTERFACE

SE-330/SE-330AU/SE-330HV DEVICENET INTERFACE 374 Kinnear Place Saskatoon, Saskatchewan Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.startco.ca SE-330/SE-330AU/SE-330HV DEVICENET INTEACE March 5, 200 Revision Copyright 200 Littelfuse Startco

More information

MICRO-SCREEN DIN Controllers with DeviceNet Trip Output

MICRO-SCREEN DIN Controllers with DeviceNet Trip Output MICRO-SCREEN DIN Controllers with DeviceNet Trip Output Supplement to MICRO-SCREEN Instruction Manual P/N 48753 Features Offers all of the features of standard MICRO-SCREEN DIN controllers (see Instruction

More information

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05 Sigma DeviceNet Tool Change Systems USER S GUIDE 94018 Rev 05 648 Saratoga Road Glenville, NY 12302 USA Phone: 518 384 1000 Fax 518 384 1200 www.arobotics.com 1. PRECAUTIONS 1 Sigma DNET Module 1 2.0 DNET

More information

User Manual FRN 1.xx 2.xx

User Manual FRN 1.xx 2.xx Allen-Bradley Bulletin 160 DeviceNet Communication Module User Manual FRN 1.xx 2.xx Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation User Manual 1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It is the installer's

More information

DeviceNet ILxxxx-B520. IO Data Mapping DeviceNet Objects Indicators and Switches

DeviceNet ILxxxx-B520. IO Data Mapping DeviceNet Objects Indicators and Switches DeviceNet ILxxxx-B520 IO Data Mapping DeviceNet Objects Indicators and Switches Version: 1.2 08.11.2006 Please note the following Target group Safety requirements This description is only intended for

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

INTEGRATED MICROSTEPPING MOTOR DRIVER AND HIGH PERFORMANCE MACHINE/PROCESS CONTROLLER

INTEGRATED MICROSTEPPING MOTOR DRIVER AND HIGH PERFORMANCE MACHINE/PROCESS CONTROLLER Sold by Servo Systems Co. 115 Main Road, P.O. Box 97, Montville, NJ 07045-0097 Toll Free: (800) 922-1103 Phone: (973) 335-1007 Fax: (973) 335-1661 www.servosystems.com INTEGRATED MICROSTEPG MOTOR DRIVER

More information

EtherNet /IP User Guide

EtherNet /IP User Guide EtherNet /IP User Guide Trademark Notices Comtrol, DeviceMaster, and PortVision are registered trademarks of Comtrol Corporation. ControlLogix, PLC-5 and Rockwell Automation are registered trademarks of

More information

CDN180 CCO SPECIFICATIONS

CDN180 CCO SPECIFICATIONS CDN180 CCO SPECIFICATIONS Revision 1.0 03/30/97 Table of Contents OVERVIEW 1 VIRTUAL PROCESSOR OBJECT (VPO) CLASS CODE: 80 (0X50) 2 VPO Class Attributes 2 VPO, Instance 1 Attributes 2 VPO Common Services

More information

METTLER TOLEDO DNB User Manual

METTLER TOLEDO DNB User Manual V 1.2 Preface The data and illustrations found in this document are not binding. reserves the right to modify our products in line with our policy of continuous product development. The information in

More information

Product Specification for CANbus to DeviceNet Transducer Gateway

Product Specification for CANbus to DeviceNet Transducer Gateway XG CANbus to DeviceNet Transducer Gateway April, 00 Product Specification for CANbus to DeviceNet Transducer Gateway The XG CANbus to DeviceNet Temposonics Gateway gathers position information from as

More information

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation HART / EtherNet/IP Gateway GT200-HT-EI V 1.0 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features... 4 1.3 Technical

More information

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

GW1000 User s Guide. Revision 1.04 Mar 30, 2008 GW1000 User s Guide Revision 1.04 Mar 30, 2008 Website: www.datalink-networks.com Tel : (604) 632-4278 / (866) 709-6390 Table of Contents 1.0 GW1000 General Operation & Applications... 3 2.0 Hardware Specifications...

More information

DeviceNet for Capacitance Diaphragm Gauge

DeviceNet for Capacitance Diaphragm Gauge Communication Protocol DeviceNet for Capacitance Diaphragm Gauge CDG045D, CDG100D, CDG160D, CDG200D tira51e1 (2009-01) 1 General Information Caution Caution: data transmission errors Any attempt to simultaneously

More information

TABLE OF CONTENTS. Communication Functions

TABLE OF CONTENTS. Communication Functions TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................

More information

ELC-CODNETM. Effective December Users Manual

ELC-CODNETM. Effective December Users Manual Effective December Users Manual Introduction This is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, excessive humidity, shock and vibration. The enclosure

More information

PROFIBUS Gateway for MCD 3000 Series Soft Starters. User Manual

PROFIBUS Gateway for MCD 3000 Series Soft Starters. User Manual PROFIBUS Gateway for MCD 3000 Series Soft Starters P/N FS-1135 User Manual Ver. 1.9 10 October 2003 Copyright 2002 Fieldbus Specialists MCD 3000 SERIES 1 USER MANUAL REVISION NOTES Index Date Chapte r

More information

PROFIBUS DP/CAN Gateway PCA-100. User Manual

PROFIBUS DP/CAN Gateway PCA-100. User Manual PCA-100 REV 4.0 SiboTech Automation Co., Ltd. Technical Support: 021-5102 8348 E-mail: support@sibotech.net Catalog 1 Introduction... 2 1.1 About This Instruction... 2 1.2 Copyright... 2 1.3 Related Products...

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

MRUC-20 Modul-R CAN Bus Network

MRUC-20 Modul-R CAN Bus Network MRUC-20 Modul-R CAN Bus Network BALOGH This manual is based on information available at the time if its publication. Every effort has been made to provide accurate and up-to-date information. This document

More information

VPGate Manual PROFIBUS to serial

VPGate Manual PROFIBUS to serial VPGate Manual PROFIBUS to serial Important information Purpose of the Manual This user manual provides information how to work with the VPGate PROFIBUS to serial. Document Updates You can obtain constantly

More information

TECHNICAL NOTE TNDA05

TECHNICAL NOTE TNDA05 TECHNICAL NOTE TNDA05 Title: Configuring a PAXCDC30 DeviceNet card with an AB 1747- SDN Scanner Card RLC Product(s): PAXCDC30 This Technical Note is intended to be used along with the Red Lion Controls

More information

DeviceNet - ODVA Conformance Test Results

DeviceNet - ODVA Conformance Test Results Test Information Scheduled Test Date July 9, 2012 Composite Test Revision 23 ODVA File Number 10105.06 Test Type Single Product DeviceNet - ODVA Conformance Test s Vendor Information Vendor Name Bronkhorst

More information

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual

GW-7472 / GW EtherNet/IP to Modbus RTU/TCP Gateway User Manual GW-7472 / GW-7473 EtherNet/IP to Modbus RTU/TCP Gateway User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, starting from

More information

DeviceNet Interface Card "OPC-F1-DEV"

DeviceNet Interface Card OPC-F1-DEV Instruction Manual DeviceNet Interface Card "OPC-F1-DEV" Thank you for purchasing our DeviceNet Interface Card OPC-F1-DEV. This product is designed to connect the FRENIC-Eco series of inverters to DeviceNet.

More information

DeviceNet - ODVA Conformance Test Results

DeviceNet - ODVA Conformance Test Results DeviceNet - ODVA Conformance Test s Test Information Scheduled Test Date January 12, 2015 Composite Test (CT) Revision CT26 ODVA File Number 11368.01 Test Type Single Product Vendor Information Vendor

More information

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual (Version 1.01) PAGE:1

More information

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB - 5G0078B0 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-/ASAB Issued on 5/06/ R. 0 This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide

More information

High Performance FieldBus cards

High Performance FieldBus cards Profibus card VLT 5000/6000...2 Interbus card VLT 5000... 4 DeviceNet card VLT 5000... 6 Modbus+ card VLT 5000...8 Lonworks card VLT 5000/6000 Free Topology... 10 Lonworks cards VLT 5000/6000 78 kbps and

More information

ZoneLink 4-Zone Controller For use with ZL.S-DK101 and Microroller

ZoneLink 4-Zone Controller For use with ZL.S-DK101 and Microroller ZLC-6320-2 0905 TECHNICAL DATA SHEET Description The enhanced Holjeron ZoneLink 4-Zone Controller for use with DeviceNet has the features needed to control up to four zones in a material handling system,

More information

BridgeWay PROFIBUS to DeviceNet Gateway User Manual

BridgeWay PROFIBUS to DeviceNet Gateway User Manual BridgeWay PROFIBUS to DeviceNet Gateway User Manual Part No. AB7605 For Firmware Revision 2.01.01 and Later Pyramid Solutions, Inc. 30200 Telegraph Road, Suite 440 Bingham Farms, MI 48025 www.pyramidsolutions.com

More information

DeviceNet Communications for PanelView Terminals

DeviceNet Communications for PanelView Terminals User Guide DeviceNet Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the DeviceNet versions of the PanelView terminals. This

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE 13022001 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS CDN220 PRODUCT OVERVIEW 1 CDN220 INSTALLATION 2 POWER

More information

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet FACTORY AUTOMATION INSTRUCTION MANUAL WCS-Interface Module, DeviceNet WCS-DG210 Part. No. 202340 / DOCT-1305 / 11. june 2007 1 Working principle............................ 6 2 Installation and commissioning.................

More information

MPU-32 AND FPU-32 TIA-485 NETWORK

MPU-32 AND FPU-32 TIA-485 NETWORK 3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/protectionrelays MPU-32 AND FPU-32 TIA-485 NETWORK SEPTEMBER 5, 2006 PRELIMINARY Publication: MPU-32/FPU-32

More information

MAC VALVES, INC. A ENGINEERING RELEASE TRJ B EDS UPDATE / NAME CHANGE BI 284 TJR/KD. User s Manual for MAC Valves DeviceNet

MAC VALVES, INC. A ENGINEERING RELEASE TRJ B EDS UPDATE / NAME CHANGE BI 284 TJR/KD. User s Manual for MAC Valves DeviceNet MAC VALVES, INC. DOCUMENT NUMBER TITLE: User s Manual for MAC Valves DeviceNet PAGE 1 OF 24 UI-20 SM16 Manifold REVISION LEVEL DATE RELEASED CHANGE ECN NUMBER P.E. APPROVAL P.D. APPROVAL A 7-21-99 ENGINEERING

More information