Installation and configuration. WebAccess and its modules for ECL Comfort 200 / 300

Size: px
Start display at page:

Download "Installation and configuration. WebAccess and its modules for ECL Comfort 200 / 300"

Transcription

1 Installation and configuration and its modules for ECL Comfort VI.KM.H2.02 Danfoss DH-SMTDK

2 Application principle Table of Contents Before you start...2 System requirements... 2 Installation address... 2 IP addresses* accounts... 2 ECL name (menu location 1-4)... 2 Heat meters... 3 Pulse interface Pulse interface Pulse interface Pulse interface Analog interface Analog interface LON wiring...6 Wiring to the ECL Comfort controller...7 LAN Ethernet wiring...9 Powering up...10 Ethernet configuration...10 Configuration of ECL Comfort controllers Configuration of modules...12 Configuration of input channels...13 IP configuration...14 Light emitting diodes...15 WAH analog interface...16 WAH pulse interface...17 Screen examples VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

3 Before you start System requirements Microsoft Explorer 6.xx browser or later versions Adobe SVG Viewer 3.xx or later versions Intranet Internet connection It is strongly recommended to write down the information that may be needed on a later occasion. Installation address IP addresses* IP address (fixed) Subnet mask Default gateway * All addresses must be written as digits accounts Name * All addresses must be written as digits ECL name (menu location 1-4) Menu option: Configuration Installation address Menu option: Configuration IP addresses Menu option: Configuration accounts SMTP addresses* Menu option: Configuration Units Heat meters Pulse interface 1 Description Pulse factor Unit Pulse interface 2 Menu option: Configuration Units Additional modules Add (Edit) Menu option: Configuration Units Additional modules Add (Edit) Menu option: Configuration Units Additional modules Add (Edit) Description Pulse factor Unit 2 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

4 Pulse interface 3 Menu option: Configuration Units Additional modules Add (Edit) Description Pulse factor Unit Analog interface 1 Menu option: Configuration Units Additional modules Add (Edit) Range Description 0 V 10 V Unit Pulse interface 4 Menu option: Configuration Units Additional modules Add (Edit) Description Pulse factor Unit Analog interface 2 Menu option: Configuration Units Additional modules Add (Edit) Range Description 0 V 10 V Unit 4 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

5 LON wiring Wiring to the ECL Comfort controller Step 1 Mount the ECA 82 LON module in the ECL Comfort controller by dismounting cover plate B on the back of the ECL Comfort by means of a small slice cutter nipper. Step 2 Mount the ECA 82 in the slides and press it gently into the connector on the ECL Comfort print board. 6 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

6 LAN Ethernet wiring Step 3 Mount the new cover plate B, which is delivered with the option card. Pin connection ECA 82: 1: LON data 1. Left side pin of the connector. 2: Middle pin of the connector. Do not use! 3: LON data 2. Right side pin of the connector. LON data 1 and 3 can be reversed. Pin connection unit: 1: LON data 1. Left side pin of the connector. 2: LON data 2. Right side pin of the connector. LON data 1 and 2 can be reversed. (TPFT-10) ECA 82 Step 4 Mount the LON connectors in the unit and in the ECA 82 module. LON termination Check that the termination jumper is mounted as FT. 8 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

7 Powering up When powering up the ECL Comfort controller, a period of about 30 seconds will elapse during which the database of the controller will be copied to the ECA 82 module. During this period it is not possible to contact the ECA 82 module, neither from the ECL Comfort controller nor from the network. The start-up period will occur in connection with reset powering up of the controller and ECA 82 module and also when the application is changed in the ECL Comfort controller. The unit needs 2-3 min. to start up. During start-up, the status LED has a constant light. The unit is ready when the status LED starts flashing. Status LED Ethernet configuration Configuration of ECL Comfort controllers Add the ECL Comfort applications to the unit: Select menu option: Configuration Units Add ECL Click Add. State the ECL name for this menu location. If you already have set up alarm recipients, choose the one to be alerted in case of communication failure. Click Continue. Follow the instructions on the screen. Edit ECL Click Edit. Edit the ECL name for this menu location. Choose alarm recipient in case of communication failure. Click save. Remove ECL Click Remove for the ECL you want to disconnect. Confirm the removal of the selected ECL by clicking Remove once again. First of all, the contact to the unit must be established. This is achieved by means of a PC (Laptop Notebook) and an xover Ethernet cable. Connect the Ethernet cable and configure your PC to the fixed IP addresses: IP: Subnet: Gateway: No Now the unit can be contacted with the IP address via the Microsoft Internet Explorer. Remember to install the Adobe SVG Viewer before contacting the unit. It can be downloaded for free from If you fail to install the Adobe SVG Viewer, you will not be able to see the application graphics. 10 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

8 Configuration of modules Select menu option: Configuration Units Additional modules Add Click Add. State the module name and choose under which ECL menu locations the module is to be shown. If you already have set up alarm recipients, choose the one to be alerted in case of communication failure. Click Continue. Follow the instructions on the screen. Edit Click Edit. Edit the module name for this menu location. Choose alarm recipient in case of communication failure. Click save. Remove Click Remove for the module you want to disconnect. Confirm the removal of the selected module by clicking Remove once again. When a new ECL unit or additional module is added, you might be asked to close your Internet browser and then restart it. This also applies if units additional modules have been changed or deleted when you close the dialog. This enables the Internet Explorer to show you the new changed units additional modules correctly. Configuration of input channels Heat meters: No additional set-up is required. WAH pulse interface: Select the under which the pulse interface is shown. Select the menu option: Modules. Click Add and confirm use of licence. Click Edit. State the name description, units (kwh or m 3 ) and pulse factor. Also state the accumulated value of the meter (actual value displayed on the meter) and the max. possible value of the meter. WAH analog interface: Select the under which the analog interface is shown. Select the menu option: Modules. Select the menu option: Modules. Click Add and confirm use of licence. Click Edit. State the name description and units. Set the range of the input device by stating the min. max. value that equals 0 and 10 V. 12 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

9 IP configuration Light emitting diodes Set the IP address, subnet mask and standard gateway of the data logger to comply with the relevant network. You can get these addresses from your network administrator or from your Internet supplier. When the IP address is changed, the data logger restarts. After a period of 2-5 min. the Internet explorer should be restarted, and the data logger can be found on the new IP address. It is extremely important to remember your IP address. Without this address, it will not be possible to access the data logger again. 1. TP FT-10 LON connection: Free topology twisted pair 2. Power supply: 8-24 V a.c. or V d.c. 3. RS 232 interface for PC connection 4. Ethernet connection 5. TP FT-10 LON connection: Free topology twisted pair 6. Wireless Constant light: Fatal error no net. It is not possible to get connected to the network (typically the SIM card is missing) Slowly flashing light (½ Hz) : Connected to GSM net found! Fast flashing light (1 Hz): Connected to dial up 7. Status Constant light: The data logger is starting up and and there is no connection Flashing light: The data logger is ready Mb Flashing light: Data are being trasmitted via the Ethernet 9. Link Constant light: The data logger is connected to the Ethernet 10. Power Constant light: The data logger is connected to the mains No light: The power is disconnected 11. Service (configuration of data logger) Flashing light: The data logger is not configured 14 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

10 WAH analog interface WAH pulse interface 16 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

11 Screen examples 18 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

12 Extension modules, serial nos. Disposal Instruction Equipment containing electrical components shall not be disposed together with domestic waste. It must be collected separately with other electrical and electronic waste according to local legislation. 20 VI.KM.H2.02 Danfoss DH-SMTDK DH-SMTDK VI.KM.H2.02 Danfoss

13 *087R9748* *VIKMH202* Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss AS. All rights reserved. 22 VI.KM.H2.02 Danfoss DH-SMTDK

Installation and configuration. WebAccess and its modules for ECL Comfort 200 / 300

Installation and configuration. WebAccess and its modules for ECL Comfort 200 / 300 Installation and configuration and its modules for ECL Comfort 200 300 VI.KM.H1.02 Danfoss 062005 DH-SMT DN Application principle 2 VI.KM.H1.02 Danfoss 062005 DH-SMT DN Table of Contents Before you start...2

More information

ECA 73 M-Bus combi module for the ECL Comfort 300S controller. Installation and User Guide

ECA 73 M-Bus combi module for the ECL Comfort 300S controller. Installation and User Guide ECA 73 M-Bus combi module for the ECL Comfort 300S controller Installation and User Guide DH-SMT/DK VI.KN.Y2.02 Danfoss 08/2008 ECA 73, M-Bus combi module for the ECL Comfort 300S Table of Contents 1.

More information

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085 ELECTRONIC CONTROLS & SENSORS AK-SC255 Fact Sheet Version R Software Software version 02_085 What s in the Box? 1x AK-SC255 (either Box or DIN rail screen-less version) What are the different part numbers?

More information

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications Installation & User Guide SonoMeter 30 Ultrasonic energy meter for heating and cooling applications www.danfoss.com 2 Danfoss Energy Meters 2016.06 VUIGJ102 1. Installation 1.1. Preparation Only qualified

More information

Installation Guide Modbus TCP Module

Installation Guide Modbus TCP Module ENGINEERING TOMORROW Installation Guide Modbus TCP Module VLT Compact Starter MCD 201/MCD 202 VLT Soft Starter MCD 500 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction 3 1.1

More information

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V. ECL Apex 20 controller and ECA 20 (ECL Apex Web Panel) Description ECL Apex 20 and ECA 20 ECL Apex 20 The ECL Apex 20 and the ECA 20 (ECL Apex Web Panel) are used in large district heating applications.

More information

Installation Guide VLT BACnet/IP MCA 125

Installation Guide VLT BACnet/IP MCA 125 MAKING MODERN LIVING POSSIBLE Installation Guide BACnet/IP MCA 125 HVAC Drive FC 102 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction 2 1.1 Purpose of the Manual 2 1.2 Additional

More information

Installation Guide VLT EtherNet/IP MCA 121

Installation Guide VLT EtherNet/IP MCA 121 MAKING MODERN LIVING POSSIBLE Installation Guide VLT EtherNet/IP MCA 121 VLT HVAC Drive FC 102 VLT AQUA Drive FC 202 VLT AutomationDrive FC 301/302 www.danfoss.com/drives Contents Installation Guide Contents

More information

Installation guide. Data communication link to m2 - LON with EKC - LonWorks

Installation guide. Data communication link to m2 - LON with EKC - LonWorks Installation guide Data communication link to m2 - LON with EKC - LonWorks RI.8B.N1.02 8-2000 Contents Introduction... 2 Principle... 3 RS 485... 4 EKC 201/301 controllers... 5 Introduction This installation

More information

Installation Guide EtherNet/IP Module

Installation Guide EtherNet/IP Module ENGINEERING TOMORROW Installation Guide EtherNet/IP Module VLT Compact Starter MCD 201/MCD 202 VLT Soft Starter MCD 500 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction 3 1.1

More information

DECS 2.0 Danfoss Energy Control System

DECS 2.0 Danfoss Energy Control System Data sheet DECS 2.0 Danfoss Energy Control System Description DECS 2.0 DECS 2.0: The Danfoss Energy Control System (DECS) is a web-based SCADA software solution (Supervisory Control And Data Acquisition)

More information

Danfoss Enspire a web-based SCADA software application

Danfoss Enspire a web-based SCADA software application Danfoss a web-based SCADA software application Description Danfoss is a web-based SCADA software application (Supervisory Control And Data Acquisition) for district heating systems. is built on strong

More information

CI-tronic Reversing contactor Type RCI

CI-tronic Reversing contactor Type RCI Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast

More information

Installation Guide DEVIlink CC Central Controller

Installation Guide DEVIlink CC Central Controller DEVIlink CC Central Controller www.devi.com Table of Contents 1 Introduction.................................... 4 2 Guidelines for installation....................... 5 3 Installation plan.................................

More information

ENGINEERING TOMORROW. User Guide. BACnet MS/TP Communication with MBS UBR-01 Router. VLT HVAC Drive FC 102 VACON 100 HVAC. vlt-drives.danfoss.

ENGINEERING TOMORROW. User Guide. BACnet MS/TP Communication with MBS UBR-01 Router. VLT HVAC Drive FC 102 VACON 100 HVAC. vlt-drives.danfoss. ENGINEERING TOMORROW User Guide BACnet MS/TP Communication with MBS UBR-01 Router VLT HVAC Drive FC 102 VACON 100 HVAC vlt-drives.danfoss.com Contents User Guide Contents 1 Introduction 2 1.1 Purpose

More information

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.

More information

Protocol interface AK-PI 200 REFRIGERATION AND AIR CONDITIONING. Manual

Protocol interface AK-PI 200 REFRIGERATION AND AIR CONDITIONING. Manual Protocol interface AK-PI 200 REFRIGERATION AND AIR CONDITIONING Manual Introduction Function The AK-PI 200 is an intermediary link allowing AKC and AKL type controllers to be operated via a system manager,

More information

Quick Start Guide Touch Screen Display Panel/ Tridium

Quick Start Guide Touch Screen Display Panel/ Tridium Quick Start Guide Touch Screen Display Panel/ Tridium *Specification may differ to that listed above Contents 1. Welcome 2. Before you begin 3. Safe design and installation 4. Touch Screen Display Panel

More information

Operating Guide FC Series Add-On Instruction for VLT EtherNet/IP MCA 121

Operating Guide FC Series Add-On Instruction for VLT EtherNet/IP MCA 121 ENGINEERING TOMORROW Operating Guide FC Series Add-On Instruction for VLT EtherNet/IP MCA 121 VLT HVAC Drive FC 102 VLT AQUA Drive FC 202 VLT AutomationDrive FC 301/302 VLT Decentral Drive FCD 302 vlt-drives.danfoss.com

More information

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway MAKING MODERN LIVING POSSIBLE Manual Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway www.danfoss.com 2 FRCC.ES.011.A1.02 CONTENTS Introduction... 4 General Description...4

More information

MAKING MODERN LIVING POSSIBLE. Flashing Manual. CD302 and CDS302. Manual

MAKING MODERN LIVING POSSIBLE. Flashing Manual. CD302 and CDS302. Manual MAKING MODERN LIVING POSSIBLE Flashing Manual CD302 and CDS302 Manual Ma n u a l In t r o d u c t i o n This manual only applies to CD302 and CDS302 Variable Speed Drives which are dedicated to Maneurop

More information

Installation Guide VLT PROFIBUS DP MCA 101

Installation Guide VLT PROFIBUS DP MCA 101 MAKING MODERN LIVING POSSIBLE Installation Guide VLT PROFIBUS DP MCA 101 VLT Frequency Converter FC 102 FC 103 FC 202 FC 301/302 FCP 106 FCM 106 vlt-drives.danfoss.com Contents Installation Guide Contents

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

DECS 2.0. Danfoss Energy Control System. Data sheet. Description DECS 2.0

DECS 2.0. Danfoss Energy Control System. Data sheet. Description DECS 2.0 Data sheet DECS 2.0 Danfoss Energy Control System Description DECS 2.0 DECS 2.0 The Danfoss Energy Control System (DECS) is a web-based SCADA software solution (Supervisory Control And Data Acquisition)

More information

Modulating controlled actuator AME 11

Modulating controlled actuator AME 11 Data sheet Modulating controlled actuator AME 11 Description In addition to basic function such as manual control and position indication, the actuators are also equipped with force sensitive switch-off

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections, CTs, and Modbus....

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E Rev. 2 December 2011 PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections,

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service... 2 Disconnect Power Connections, CTs, and Modbus....

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters SonoSelect and SonoSafe energy meters Description The Danfoss SonoSelect and SonoSafe are ultrasonic compact energy meters intended for measuring energy consumption in heating applications for billing

More information

All it takes to measure, collect and analyze energy consumption in heating and cooling applications

All it takes to measure, collect and analyze energy consumption in heating and cooling applications Energy metering Product overview All it takes to measure, collect and analyze energy consumption in heating and cooling Discover the full range of ultrasonic heat & cooling meters and monitoring solutions.

More information

MultiModem rcell. Intelligent Wireless Router. Quick Start Guide

MultiModem rcell. Intelligent Wireless Router. Quick Start Guide MultiModem rcell Intelligent Wireless Router Quick Start Guide Copyright and Technical Support Quick Start Guide MultiModem rcell MTCBA-Xx-EN2 82100400L, Revision A Copyright 2009 by Multi-Tech Systems,

More information

Installation Guide VLT Programmable I/O MCB 115

Installation Guide VLT Programmable I/O MCB 115 MAKING MODERN LIVING POSSIBLE Installation Guide VLT Programmable I/O MCB 115 VLT AutomationDrive FC 302 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction 2 1.1 Purpose of the

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort V a.c. and 24 V a.c. Data sheet ECL Comfort 200 230 V a.c. and 24 V a.c. Application The ECL Comfort 200 electronic controller is pre-programmed for a variety of different applications. Each application has its own card describing

More information

MultiModem rcell Intelligent Wireless Router. Quick Start Guide

MultiModem rcell Intelligent Wireless Router. Quick Start Guide MultiModem rcell Intelligent Wireless Router Quick Start Guide Copyright and Technical Support Quick Start Guide MultiModem rcell MTCBA-Xx-EN2, MTCBA-Xx-EN2-GP 82100511L, Revision A Copyright 2010 by Multi-Tech

More information

Configuring the 20xx Inbuilt Ethernet Device.

Configuring the 20xx Inbuilt Ethernet Device. Configuring the 20xx Inbuilt Ethernet Device. V1.1-1 - Contents Configuring the 20xx Inbuilt Ethernet Device.... 1 Contents... 2 Overview... 3 Prerequisites... 3 Setting the 20xx Loggers IP Address....

More information

QUICK START G U I D E. GWG Gateway GWG-30, GWG-40

QUICK START G U I D E. GWG Gateway GWG-30, GWG-40 QUICK START G U I D E GWG Gateway GWG-30, GWG-40 WHAT S IN THE BOX: 1. GWG Gateway 2. Power supply cord (AC/DC adapter - optional) 3. Antenna GSM/GPRS/EDGE/UMTS/HSPA+/LTE ) (800/900/1800/2100/2600 MHz)

More information

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax: Description of options TCP/IP Ethernet module user s manual DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189320029B Legal information

More information

MCX08M2 Programmable controller

MCX08M2 Programmable controller Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection

More information

Protocol interface AK-PI 300

Protocol interface AK-PI 300 User Guide Protocol interface AK-PI 300 ADAP-KOOL Refrigeration control systems Introduction Function The AK-PI 300 is an intermediary link allowing Daikin type controllers to be operated via a System

More information

Danfoss Enterprise Manager AK-EM 800

Danfoss Enterprise Manager AK-EM 800 Installation Guide Danfoss Enterprise Manager AK-EM 800 ADAP-KOOL Refrigeration Control System Document history Document Notes USCO.PI.R1.F1.02 First document release USCO.PI.R1.F2.02 Minor updates USCO.PI.R1.F3.02

More information

AK-SM 720 Boolean logic REFRIGERATION AND AIR CONDITIONING. User guide

AK-SM 720 Boolean logic REFRIGERATION AND AIR CONDITIONING. User guide AK-SM 720 Boolean logic REFRIGERATION AND AIR CONDITIONING User guide Application The function is contained in System manager type AK-SM 720 and can be used for user-defined functions. The functions can

More information

Actuators for modulating & 3-point control

Actuators for modulating & 3-point control Data sheet Actuators for modulating & 3-point control AME 655 without safety function AME 655 GA without safety function (replacement for AMV(E) 4xx/6xx) AME 658 SU, AME 658 SD with safety function (spring

More information

DECS 2.0 Danfoss Energy Control System

DECS 2.0 Danfoss Energy Control System Operating Guide DECS 2.0 Danfoss Energy Control System English version www.danfoss.com Table of Contents Page Introduction 3 DECS 2.0 3 Important product information 4 Application examples 5 Accessing

More information

L2+ Managed Metro Ethernet Switch MGSW / MGSD Series

L2+ Managed Metro Ethernet Switch MGSW / MGSD Series L2+ Managed Metro Ethernet Switch MGSW / MGSD Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5 4. Terminal Setup... 6 5. Logon

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4

More information

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Product names mentioned in this manual may be trademarks or registered trademarks of those products. FCC Statement The FCC (Federal Communications Commission) restricts the amount of radio frequency emission and radiation coming from computer equipment. The equipment introduced in this manual has been

More information

SonoSelect 10 and SonoSafe 10 energy meters

SonoSelect 10 and SonoSafe 10 energy meters SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating applications

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel:

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: Energy Client Version 2.0.806 3. Feb. 2014 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: +45 88 80 75 80 www.electrocom.dk p. 2 Introduction... 3 Installation... 4 LED, Switches and Reset...

More information

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Hardened Web-Smart PoE & High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart PoE (Power over Ethernet) and High Power PoE Ethernet Switch. This is the switch of choice for harsh environments

More information

Lodam Condensing Unit Controller. Technical manual. Version 5.0 LOM320-LMC340

Lodam Condensing Unit Controller. Technical manual. Version 5.0 LOM320-LMC340 Lodam Condensing Unit Controller Technical manual Version 5.0 LOM320-LMC340 Contents 1. Read this first... 4 1.1. Reading instructions... 4 1.2. User manual...........................................................................................

More information

ECL Comfort 296 controller and Remote Control Unit ECA 30 / 31

ECL Comfort 296 controller and Remote Control Unit ECA 30 / 31 Data sheet ECL Comfort 296 controller and Remote Control Unit ECA 30 / 31 Designed in Denmark Description ECL Comfort 296 controller series ECL Comfort 296 controller: The ECL Comfort 296 is an electronic

More information

F Series Indoor Fixed IP Camera. Quick Start Guide

F Series Indoor Fixed IP Camera. Quick Start Guide F Series Indoor Fixed IP Camera Quick Start Guide Welcome Thank you for purchasing our IP camera! Before install and use the IP camera, please read the following section carefully. Please keep this start

More information

Refrigeration and Air Conditioning Controls. Technical Leaflet. Monitoring, Control and Alarm System m2 REFRIGERATION AND AIR CONDITIONING

Refrigeration and Air Conditioning Controls. Technical Leaflet. Monitoring, Control and Alarm System m2 REFRIGERATION AND AIR CONDITIONING Refrigeration and Air Conditioning Controls Technical Leaflet Monitoring, Control and Alarm System m2 REFRIGERATION AND AIR CONDITIONING Introduction The m2 has been developed to provide a comprehensive,

More information

BD Controller 101N07xx Series 24 V DC with Tool4Cool LabEdition software Operating Instructions

BD Controller 101N07xx Series 24 V DC with Tool4Cool LabEdition software Operating Instructions MAKING MODERN LIVING POSSIBLE with Tool4Cool LabEdition software Operating Instructions 2 DEHC.PS.100.I.02 1.0 Introduction 1.1 Applications... 5 1.2 Capability... 5 1.3 Functions... 5 1.4 Programming

More information

Version 1.0c May 6, 2010 ATK3

Version 1.0c May 6, 2010 ATK3 Version 1.0c May 6, 2010 ATK3 Contents 1 Hardware 2 1.1 Inputs............................... 2 1.2 Outputs.............................. 3 1.3 RS485............................... 3 1.4 Ethernet..............................

More information

GPS NTP Time Server for Intranet Networks DIN RAIL Version

GPS NTP Time Server for Intranet Networks DIN RAIL Version GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with Ethernet connectivity

More information

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng IntesisBox Modbus Server KILSEN KSA-7xx User s Manual 08/2013 r1.2 eng Intesis Software S.L. 2013 All rights reserved. Information in this document is subject to change without notice. The software described

More information

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide 24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed Metro Ethernet Switch MGSW-28240F Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5

More information

Two-Input Wallplate Switcher for HDMI with Ethernet- Enabled HDBaseT Output

Two-Input Wallplate Switcher for HDMI with Ethernet- Enabled HDBaseT Output Two-Input Wallplate Switcher for HDMI with Ethernet- Enabled HDBaseT Output Installation Guide The Atlona is a 2x1 switcher and HDBaseT transmitter with two HDMI inputs. It features a US one-gang, Decora-style

More information

Poseidon MANUAL

Poseidon MANUAL Poseidon2 4002 MANUAL www.hw-group.com 2 Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested

More information

AK-SC255 Fact Sheet & Recommended Accessories List

AK-SC255 Fact Sheet & Recommended Accessories List AK-SC255 Fact Sheet & Recommended Accessories List E software version 02_101 Updated Dec 09 REFRIGERATION AND AIR CONDITIONING What is the E version and how does it differ from the R version? The E version

More information

Anybus Wireless Bridge II

Anybus Wireless Bridge II Anybus Wireless Bridge II STARTUP GUIDE SCM-1202-013/SP2167-EN 1.7 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial

More information

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3) These instructions provide technical and installation information for the MCC 107 EMC filter series. Only Danfoss qualified personnel is allowed to install this equipment. The personnel must be familiar

More information

Operation and installation manual KNX IP BAOS 774. KNX IP BAOS 774 as application specific Gateway BAOS SDK. Application. Installation and Connection

Operation and installation manual KNX IP BAOS 774. KNX IP BAOS 774 as application specific Gateway BAOS SDK. Application. Installation and Connection EN Operation and installation manual KNX IP BAOS 774 (Art. # 5263) Compact bus powered Interface and ObjectServer between LAN and KNX bus Protocol descriptions can be downloaded at the KNX IP BAOS 774

More information

IP Indoor High Speed Dome CAM Ver Quick Installation Guide

IP Indoor High Speed Dome CAM Ver Quick Installation Guide IP Indoor High Speed Dome CAM-6510 Ver. 090318 Quick Installation Guide 1 1 Getting Started 1.1 PACKAGE CONTENTS CAM-6510 Warranty Card Software CD Power & A/V Cable LAN/WAN Cable Power Adaptor 5.4 Transparent

More information

Operation and installation manual KNX IP BAOS 773. KNX IP BAOS 773 as application specific Gateway BAOS SDK. Application. Installation and Connection

Operation and installation manual KNX IP BAOS 773. KNX IP BAOS 773 as application specific Gateway BAOS SDK. Application. Installation and Connection EN Operation and installation manual KNX IP BAOS 773 (Art. # 5262) Compact bus powered Interface and ObjectServer between LAN and KNX bus KNX IP BAOS 773 as application specific Gateway To connect to non-knx

More information

Huawei Solar Product Training HUAWEI TECHNOLOGIES CO., LTD.

Huawei Solar Product Training HUAWEI TECHNOLOGIES CO., LTD. Huawei Solar Product Training HUAWEI TECHNOLOGIES CO., LTD. Contents Overview of the Product Range Huawei Solar Inverter Technical Information Huawei Smartlogger Technical Information NetECO Portal Brief

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa MAKING MODERN LIVING POSSIBLE MCX15B electronic controller MCX15B is fitted with or without graphic LCD display. It is an electronic controller that stands on the top of the MCX range, thanks to the large

More information

Installation Instructions for UL Rev A

Installation Instructions for UL Rev A NetController II Installation Instructions for UL 864 30-3001-1008 Rev A Mounting Screw Andover Continuum Power Supply Connector Third-Party Power Supply Connector I/O Bus Connector Cover Mounting Screw

More information

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1 User guide SonoMeter 30 Ultrasonic energy meter for heating and cooling applications Danfoss 2018.01 VUIGI102 1 Contents 1. Safety information... 3 2. Application field... 3 3. How to operate the heat

More information

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power

More information

Installation Guide PROFINET Module

Installation Guide PROFINET Module ENGINEERING TOMORROW Installation Guide PROFINET Module VLT Compact Starter MCD 201/MCD 202 VLT Soft Starter MCD 500 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction 3 1.1 Purpose

More information

WARNING ELECTRICAL SHOCK HAZARD

WARNING ELECTRICAL SHOCK HAZARD Description Safety Instructions The top-entry sub D9 connector kit is designed for enclosure sizes D1h D8h, E1 E2, and E1h E4h with VLT PROFIBUS DP MCA 101 option. It fits the following drives: VLT HVAC

More information

Instruction AKD LonWorks ADAP-KOOL AK-LON

Instruction AKD LonWorks ADAP-KOOL AK-LON Instruction AKD LonWorks ADAP-KOOL AK-LON ADAP-KOOL AKD-LonWorks 1 Copyright 1Copyright 1.1 Copyright 1 1.1.1 Copyright, Limitation of Liability and Revision Rights This publication contains information

More information

HDD external enclosure for data-storage mobility with LAN sharing LAN MAC. USER Manual

HDD external enclosure for data-storage mobility with LAN sharing LAN MAC. USER Manual HDD external enclosure for data-storage mobility with LAN sharing LAN MAC USER Manual English AKASA Company notices The information contained in this document is subject to change without notice. All rights

More information

Installation Guide AT-HDVS-210U-TX-WP

Installation Guide AT-HDVS-210U-TX-WP Two-Input Wallplate Switcher for and with Ethernet-Enabled HDBaseT Output The Atlona is a 2x1 switcher and HDBaseT transmitter with and inputs. It features a US one-gang, Decora-style wallplate form factor,

More information

4 Channel GSM Controller Installer Manual

4 Channel GSM Controller Installer Manual ! WARNING! Only fully Qualified Personnel should install or service this Device. 4 Channel GSM Controller Installer Manual 4 Channel Controller 2T-Technology www.2t-tec.com SN: 01001 Device Telephone Number:

More information

This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed.

This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed. This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed. The OCIO GSM system Transmit tank levels, via SMS and e-mail, on request.

More information

User Guide. Online.

User Guide. Online. www.thermia.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Thermia Värmepumpar Table of

More information

Service Managed Gateway TM. Installing and Configuring the GW8600 SMG

Service Managed Gateway TM. Installing and Configuring the GW8600 SMG Service Managed Gateway TM Installing and Configuring the GW8600 SMG Issue 1.1 Date 14 August 2007 Table of Contents 1 About this document...3 1.1 Scope...3 1.2 Readership...3 1.3 More information...3

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

Header code Command code Data code End code HEX Command Data 0Dh ASCII V Command Data CR

Header code Command code Data code End code HEX Command Data 0Dh ASCII V Command Data CR RS-232C Protocol RS232 Setting Baud rate: 9600 Parity check: Data bit: 8 Stop bit: 1 Flow Control UART16550 FIFO None None Disable Minimum delay for next command: 1ms Control Command Structure APPENDIX

More information

GREENBOX EV. User Guide. Revision 1.3

GREENBOX EV. User Guide. Revision 1.3 GREENBOX EV User Guide Revision 1.3 Table of Contents Chapter Page Description Chapter 1. 3 Glossary Chapter 2. 4 Introduction 4 General Operation Chapter 3. 5 Packaging 5 Content 5 Identification Label

More information

SR-201 Network Relay Quick Start Guide

SR-201 Network Relay Quick Start Guide SR-201 Network Relay Quick Start Guide Table of Content Connect to your device...2 Change configurations...3 Setup remote control via internet...4 Android software...5 Integrate to your applications...6

More information

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide Industrial 24-Port 10/100/1000Mbps Managed Gigabit Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4

More information

Product Datasheet NK8231 CEI interface for a single subsystem

Product Datasheet NK8231 CEI interface for a single subsystem Product Datasheet NK8231 CEI interface for a single subsystem NK8000 MP4.40 The NK8231 CEI interface for a single subsystem is used to connect a local or distributed intrusion detection system to MM2000

More information

Streamer VIP User s Manual

Streamer VIP User s Manual Streamer VIP User s Manual About the Cover Image The cover image illustrates a Streamer VIP V2.3. A wireless version of the Streamer VIP that includes an external antenna is available also. This manual

More information

Expert Power Control NET 4x DIN

Expert Power Control NET 4x DIN Expert Power Control NET 4x DIN 2009 Gude Analog- & Digitalsysteme GmbH 2009 Gude Analog- & Digitalsysteme GmbH 14.12.2009 Content 3 Table of contents 1 Security Advise 4 2 Description 5 3 Hardware 3.1

More information

Ethernet Adapter Installation Instructions

Ethernet Adapter Installation Instructions Ethernet Adapter Installation Instructions DOC. #569040000 A 7/30/04 PRINTED IN U.S.A. Disclaimer Logic One is a registered trademark of Novar Controls Corporation. The material in this manual is for information

More information

Installation Guide VLT DeviceNet MCA 104

Installation Guide VLT DeviceNet MCA 104 MAKING MODERN LIVING POSSIBLE Installation Guide VLT DeviceNet MCA 104 VLT Frequency Converter Series FC 102 FC 202 FC 301 FC 302 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction

More information

How to register your user account and ECL Comfort 310 controller to the ECL Portal

How to register your user account and ECL Comfort 310 controller to the ECL Portal How to register your user account and ECL Comfort 310 controller to the ECL Portal 1.0 Contents 1.0 Contents...1 2.0 Introduction...2 2.1 Use the ECL Portal to take control of your plant...2 2.2 Application

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G 3891 0052 Built-in Dupline channel generator Modbus/TCP Slave 10 and 100 Mbit operation, full or half duplex Twisted pair cables

More information

Poseidon MANUAL

Poseidon MANUAL Poseidon2 3266 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied

More information

GV-I/O Box 4E. Contents

GV-I/O Box 4E. Contents GV-I/O Box 4E Contents 1.1 Key Features... 2 1.2 System Requirements... 2 1.3 Packing List... 2 1.4 Overview... 3 1.5 Connecting to PC... 4 1.5.1 RS-485 Wiring... 4 1.6 Assigning Device ID to GV-I/O Box

More information

SolarVu Installation Guide For SunEdison System Replacement

SolarVu Installation Guide For SunEdison System Replacement -V V L N SEEDS R SolarVu Installation Guide For SunEdison System Replacement Introduction SolarVu is an energy portal that enables remote monitoring of renewable energy generation sites over the internet.

More information