ConsolePlus (EA- SWP- PLUS) User Manual Ver. 3.2

Size: px
Start display at page:

Download "ConsolePlus (EA- SWP- PLUS) User Manual Ver. 3.2"

Transcription

1 ConsolePlus (EA- SWP- PLUS) User Manual Ver. 3.2

2 Contents 1. Quick start Guide Features Dependences Accessories Installation Introduction General Tab Show Help Window Auto download logger Auto Save logger Auto generate CSV file Auto generate PDF file Auto open PDF Unit Display MKT Act. Energy Time- Zone Default Path Multi- link / Analysis User Admin add- on Version number View Tab Language Tab Main Window Main Menu Logger Logger/file list Icons & functions Tabs Program & Configure Program Tab Introduction Password Protection Pre- defined Settings Program Template Lock Program Settings Program: Final Confirmation Download Auto download Manual download: Graph Mouse Zoom: Mouse Tool Tip: Save/ save as Auto- open PDF Histogram Table Summary Rev. 3.2 Page 2

3 18. Bookmark MKT Multilink Battery Status Print / Print- preview Update Console Plus is new revolutionary software for new product line imini, imini USB PDF, xtag and all future releases of Cryopak Verification Technologies (CVT) products. It has all features to program, download, view and analyze critical data. 1. Quick start Guide ConsolePlus software currently supports following product range Product Family Product code Type Total No. of Sensors Sensor Location Sensor Type imini (yellow case) imini (yellow case) imini (yellow case) imini (yellow case) imini (yellow case) imini (yellow case) imini (yellow case) iminiusb pdf (Plug & Play) iminiusb pdf (Pharma) MX-IN-S-8-L Multi-use 1 Internal NTC MX-ST-S-8-L Single Use 1 Internal NTC MX-OE-S-8-L Multi-use 1 External NTC MX-1E-S-8-L Multi-use 2 One Internal & One External NTC MX-2E-S-8-L Multi-use 2 Both External NTC MX-HS-S-8-L Multi-use 2 Both Internal MX-HE-S-8-L Multi-use 3 Two Internal & One External Digital sensor Digital sensor & NTC MS-ST-S-8 Single Use 1 Internal NTC MS-ST-S-8-P Single Use 1 Internal NTC All new products from CVT will be supported by ConsolePlus. Software has built in auto update feature, when a new release is available it will prompt user to upgrade to newest version. And with one click it will be updated. Rev. 3.2 Page 3

4 2. Features ConsolePlus is all in one solution to support all new developed loggers by CVT. Software is designed by keeping in mind the ease of use, simplicity and useful features Lets you program & configure, download and view temperature/rh data with Lets you manage, sort, and query large amounts of data. Supports Celsius and Fahrenheit unit of measurement Multi-language, six languages supported: English, French, Spanish, Italian, German and Portuguese. 21CFR part 11 Compliance (with User Admin Package add-on) Data can be exported in multiple file format *.cvt. *.txt, *.csv and *.pdf Multi-link analysis, based on real time and based on 1st reading Export multi-link data in *.txt and *.csv format Auto download/open Auto Save in downloaded data in default secure format (*.cvt) Auto Save downloaded data in *.txt and *.csv format Auto save 'PDF', auto open PDF (latest adobe reader must be installed) 1 click PDF generation Software auto update, when a new version is available ConsolePlus prompts for an update Auto detect COM port, no separate device driver required Multiple logger download Save 'Program settings as Template for later use (*.xtp format) Worldwide Time Zone support (including daylight savings) Password protection feature with enable read / write access Data display in Histogram (including multi-linked data) Out- of- specification detail (including multi-linked data) Detailed summary (including multi-linked data) Interactive graph (including multi-linked data) Feature to add comments in graph (comments will be save in *.cvt & *.pdf files) Multiple device support Supported multiple windows Operating Systems Help window Display logger s Battery Status Display logger s Memory Status Display logger s Previous program settings Rev. 3.2 Page 4

5 3. Dependences Minimum requirements to install ConsolePlus software No. Prerequisite 1. Computer with Windows Operating Systems, One of the following OS installed Windows XP Windows Vista Windows 7 Windows 8 2. The standard USB 5-pin to Mini-B cable is available (for imini series data loggers) 3. ConsolePlus setup file ConsolePlus Installer CD disk Internet connection available (ConsolePlus software download) 4. Notepad application installed 5. Adobe PDF application v7.0 or above installed 6. Microsoft Excel application is installed Important Notes: To install ConsolePlus, the user must have administrative rights on the computer where installation is being performed. If not, installation may return with error. Please contact your network administrator for the installation. Adobe reader (latest Version) must be installed on the computer. If not, user may encounter error in PDF generation Print Print preview Software crash Rev. 3.2 Page 5

6 4. Accessories For all imini data loggers Type A to Mini-B USB cable is required to connect data logger to the workstation. ConsolePlus will auto detect the logger (no need to select COM port) IMINI to PC connection To connect the USB interface gently pull the USB cover from the rear side of imini and plug in the Mini-B side of the cable to the female connector. Connect other side of the cable to Computer s available USB port. Device driver is automatically installed during installation of ConsolePlus, so no separate driver installation is required. iminiusb pdf data logger is Plug and Play data logger, with USB onboard, no interface required. IMINIUSB pdf Rev. 3.2 Page 6

7 5. Installation Setup disk can be purchased from CVT / local distributor or setup file can be downloaded from our website or for free. File name: ConsolePlusSetup.exe / ConsolePlusSetup.zip 5.1. The installation must be performed by the user with administrative rights on the computer Double click the zip file and browse to EXE file of setup. Now double click on setup file Once double clicked ConsolePlusSetup.exe file, it may ask for security approval to proceed with the installation. Press OK to proceed through installation wizard: Important Note: Version number can be different than displayed here as the ConsolePlus software is being updated regularly for various features and fixes. Installation wizard Rev. 3.2 Page 7

8 5.4. Select the desired destination directory for installation or leave it as default directory and click Next 5.5. Select the desired destination folder for installation or leave it as default directory and click Next 5.6. Leave the option create a desktop icon checked, if ConsolePlus desktop icon is needed and click Next 5.7. Press Install to proceed with installation Rev. 3.2 Page 8

9 5.8. Setup will continue installation 5.9. A window will pop up with a message to install necessary COM drivers installation, click Install to install the necessary drivers After the device drivers installation, setup will successfully complete installation and display message to close the wizard. Click Finish Desktop icon will be created and placed on desktop (if selected in step 4.6) 6. Introduction ConsolePlus shortcut icon is created and placed on desktop after the installation is completed. Launch ConsolePlus a. When ConsolePlus application is launched for the first time, by default options window pop up (general tab) where user input is required for setting up default directory and other settings b. On the top Left Corner next to ConsolePlus *.** denotes current version of software c. Default path is highlighted in red, where user can set the default path d. Once default path is assigned, the color becomes black Rev. 3.2 Page 9

10 6.1. General Tab General settings displayed here ConsolePlus: Options General Tab 14. Version Number 1. Enable HELP window 2. Enable Auto DOWNLOAD 3. Enable Auto SAVE 4. Enable Auto Generate TEXT 5. Enable Auto Generate CSV 6. Enable Auto Generate PDF 7. Enable Auto OPEN PDF 8. Select Default Temp. Units 9. Set MKT Activation energy value 10. Current Date/time displayed Select correct Time Zone & Enable/Disable Daylight saving 11. Select Default path for all files 12. Multi- link *.cvt files Based on real-time Or 1 st reading 13. To enable User Admin Package 21CFR part 11 Compliance Important Note: Auto open pdf will be greyed out if the latest version of adobe reader is not installed or if not set as default pdf reader. If third party pdf reader is installed and used by default, in that case auto open pdf may be greyed out as well, however pdf generation from the menu icons can be performed. Rev. 3.2 Page 10

11 Information General Tab, Show Help Window Auto download logger Auto Save logger Auto generate TXT file Auto generate CSV file Auto generate PDF file Auto open PDF Program tab When a supported logger is connected with computer & ConsolePlus is already launched Unit Display Global C / F MKT Act. Energy Global Time-Zone Global Default Path Global Multi-link / Analysis User Admin add-on Global Global Select to enable (view) help window on right hand side of program tab If enabled, data will be downloaded automatically and can be viewed in ConsolePlus If enabled, data will be downloaded automatically and saved in encrypted *.cvt format to default directory. If enabled, data will be downloaded automatically and saved in *.txt format to default directory. If enabled, data will be downloaded automatically and saved in *.csv format to default directory. If enabled, data will be downloaded automatically and saved in *.pdf format to default directory. If enabled, downloaded & saved pdf will automatically from default directory will automatically in adobe reader application Default value exist, user can set custom value here Set it prior to use, select local time zone and daylight saving option Set it prior to use, the destination folder where all the data in different formats will be saved Select the option, how to analyze multi-linked data To enable user admin package add-on (21 CFR part 11 compliance) Version number Global Current version of ConsolePlus software Show Help Window If this option is enabled on general tab, help window will be displayed on right hand side of program tab. Help window displays information about the respective field of program tab, when mouse is hovered on a text or field Help Window Program Tab Help Window Mouse pointer Rev. 3.2 Page 11

12 6.1.2 Auto download logger If enabled, data will be downloaded automatically from the connected data logger (supported product). When a logger is connected as soon as ConsolePlus application is launched the data of the logger will be automatically downloaded and displayed in all available tabs of ConsolePlus. If the logger has no recorded data, it will show blank graph, histogram & table. Summary and program settings of previous trip can be viewed. If multiple loggers connected, ConsolePlus will auto download all the connected loggers. To view the data of more than one connected logger, use have to select the particular logger from left hand side pane. If a logger is connected and data is not saved before the ConsolePlus application is closed, a warning message is displayed for user to confirm if the downloaded data is need to be saved before the application quits. Now user can confirm or ignore the message as needed. Warning Message, when data is not saved! Auto Save logger This option is very supportive to user and being it fully automated it saves time and user does not need to remember if the data is saved. If enabled, data will be downloaded data of connected logger will be saved in *.cvt format to default directory. CVT format is very unique, encrypted Cryopak s data file type. The data of this file can only be viewed with ConsolePlus application only. Auto saved data *.cvt file is saved in default directory automatically without any user input. The process is very quick and is not required any waiting time. No confirmation will be displayed upon file save as the process happens in background. Auto saved files are saved in very nifty way, filename appears as: (Logger s serial number)_(trip number).cvt Example: MX-CD _0004.cvt If a logger is downloaded multiple times, next file is saved as (Logger s serial number)_(trip number)_(file number).cvt Example: MX-CD _0004_001.cvt Auto generate TXT file This option will save the data of the connected logger in *.txt format, which can be viewed in any text reader application (notepad/ WordPad). The filename will be same as in with the extension *.txt. (Logger s serial number)_(trip number).txt Example: MX-CD _0004.txt or MX-CD _0004.txt Or MX-CD _0004 or MX-CD _0004 On some computers extension can be hidden. Rev. 3.2 Page 12

13 6.1.5 Auto generate CSV file This option will save the data of the connected logger in *.csv format, which can be viewed in Office application (Microsoft Excel). The filename will be same as in with the extension *.csv. (Logger s serial number)_(trip number).csv Example: MX-CD _0004.csv or MX-CD _0004_001.csv Or MX-CD _0004 or MX-CD _ Auto generate PDF file This option will save the data of the connected logger in *.pdf format, which can be viewed in any PDF viewer application (Adobe Reader). The filename will be same as in with the extension *.pdf. (Logger s serial number)_(trip number).pdf Example: MX-CD _0004.pdf or MX-CD _0004_001.pdf Or MX-CD _0004 or MX-CD _ Auto open PDF If this option is enabled, the auto generated pdf of connected & downloaded logger will be automatically displayed in default pdf application. Auto open pdf may be greyed out if the latest version of adobe reader is not installed or if not set as default pdf reader. If third party pdf reader is installed and used by default, in that case auto open pdf may be greyed out as well, however pdf generation from the menu icons can be performed. Important Note: This option can be disabled on some computers due to some registry issues Unit Display ConsolePlus supports C / F temperature units. Units can be set on general tab and they are globally effecting the units in auto save features. User can change these units at any time as required. Downloaded data and saved *.cvt files are not affected, data will display with the set units accordingly MKT Act. Energy Mean kinetic temperature (MKT) is a simplified way of expressing the overall effect of temperature fluctuations during storage or transit of perishable goods. User can set is the Activation Energy according to their SOPs or as required. Default value of Activation Energy is kj mol - 1 ConsolePlus allow users to customize activation energy. User can view Mean Kinetic Temperature; on summary tab or generated pdf (on page 2 under alarms section) Time-Zone When ConsolePlus is installed, it is advised to set the time zone to local time-zone as the ConsolePlus do not collect this information automatically. Time-zone must be set prior to use of the application. Current local time is displayed in the window above time-zone Time- Zone Daylight savings option must be selected for the effective regions. Ensure to verify the time is matching with computer s time before using ConsolePlus. Rev. 3.2 Page 13

14 Default Path Ensure to select the destination folder carefully here, by clicking by creating a new folder at desired location. Default Path All the files with which are manually saved or auto saved will be stored in the designated directory. and browsing to desired location or Multi-link / Analysis Refer to page User Admin add-on To enable User Admin Package add on for ConsolePlus application, which is 21 CFR part 11 compliant. Please contact your local distributor on Cryopak to purchase serial number to enable this feature. For more information refer to User Admin Package user manual Version number Software versioning is the process of assigning unique version names. It is advised to use the latest version available View Tab In View Tab, Graph and Histogram color settings can be changed and set as required. User can change the desired colors in available options or reset to defaults as needed. Rev. 3.2 Page 14

15 6.3. Language Tab Choose the preferred language to use from the available six languages Rev. 3.2 Page 15

16 7. Main Window Once the desired settings have been made, click OK on the options window to view the application. Home page is displayed and most of the tabs and functions are greyed out (when no logger is connected). User can change settings any time as required by selecting options. Main Menu Action Icons Informati on Tabs Connected Logger or opened files can be viewed Home Tab (Web Page) Progress Bar Program / Download 7.1. Main Menu Main menu has three key options, File: General options, including open/close files, load/save template, print functions and updates Logger: Program, download & program lock functions Help: Information about software releases Most of the functions in the tree are disabled initially and will be highlighted or available depending on if the data logger is connected or if a file is open. Rev. 3.2 Page 16

17 Main menu - File Open a previously saved file (target default directory) Save downloaded data of a logger Save downloaded data of a logger in different format, csv / txt Remove selected files from multiple open files Remove all opened files Select to open options window Open a previously saved program template, to program logger Save a new program template, based on new program settings Generate PDF of selected file (save in default directory) Display print preview Send data to print Manually check for available software updates Exit ConsolePlus application 7.2. Logger Main menu: Logger Logger Menu has basic functions to download data of connected logger, lock function to lock the program settings to program multiple loggers with same settings and program function Logger/file list This window display the following information, If it is a logger or a file is opened. COM port number of connected logger (if available). Filename / path of an opened file. Serial number of logger. Quick alarm status. Alarm status is displayed with the colored icons as described in the table. If the connected logger is in ready state or no data is available then a green icon (OK) will be displayed. Alarm status Text Description Icon LL If Low Low Alarm has triggered L If Low Alarm has triggered OK If no alarm has triggered H If High Alarm has triggered HH If High High Alarm has triggered Rev. 3.2 Page 17

18 8. Icons & functions The information of the action icons is displayed below. These icons will be enabled only if the logger is connected and assigned action is conceivable. Action icons 9. Tabs Tabs Home: Cryopak homepage is displayed on this tab. Program: Program settings of a programmed logger, or to program a connected data logger. Graph: Graph view of downloaded data of a logger or a file. Histogram: Histogram view of downloaded data of a logger or a file. Table: Data/readings of all sensors of downloaded data of a logger or a file. Summary: Summary view of downloaded data of a logger or a file. 10. Program & Configure To Program any ConsolePlus supported product, first of all a logger must be connected to computer (imini, iminiusb pdf or new released supported loggers). As soon as the logger is connected ConsolePlus will recognize it automatically and display the connected logger s information on left hand pane (logger/file list). Important Note: In order to program the logger, data of the logger must be downloaded first. Program icon will be disabled if the data is not downloaded. The program option will only be enabled if it is downloaded first. Program tab (to set the program parameters or view previous settings) will appear Progress bar - Download Rev. 3.2 Page 18

19 only when the data is downloaded. If auto download is not enabled, ConsolePlus will wait for user input to press download (by clicking download icon or from main menu, selecting logger and then clicking download). If auto download is enabled, ConsolePlus will immediately download the data. A progress bar of download will appear below logger/ file list (as shown on main window). After the download, by default graph tab appears, from tabs browse to program tab. Program window will appear (as shown below). In this window all the previous program settings of the logger can be viewed. For the ease, all the program parameters can be set in same window instead of going multiple pop-up windows. Program Tab Connected logger in logger/file list Program icon is also available here Depending on the logger type and available sensors of the logger, sensor information will be displayed on program tab. Screenshot (above) display MX-HE-S-16-L, it has three supported sensors. Title of the sensor tabs will be different depending on sensor type (NTC / Digital sensor). Loggers with temperature sensors will be Int/Ext.Temp.(NTC) Loggers with humidity sensors will be Int. Temp.(Digital) Rev. 3.2 Page 19

20 10.1. Program Tab Introduction Some of the fields are read only, please refer to table below. 24 No. Decription Details Field type 1 Firmware ver. of connected logger (or the logger of saved file) Read only 2 Enter Password Maximum five numbers (exceeding will Write only erase the field) 3 Allow to download the logger Without password Enable / Disable 4 Allow to program the logger Without password Enable / Disable 5 Serial number of the logger (unique for each logger) Read only 6 Product code of the logger (unique for each logger type) Read only 7 Memory size of the logger (total size) Read only 8 Trip number of the logger How many times logger has been used Read only 9 Temperature range of the logger (of the logger) Read only 10 Description Vary by product, refer to the product user manual Read / Write 11 Sensor Int.temp./ext.temp./Humidity (tab enabled if sensor available) Read only 12 High High Alarm threshold Read / Write 13 High Alarm threshold Entries must be in mathematically correct Read / Write 14 Low Alarm threshold and in the order of: HH > H> L> LL Read / Write 15 Low Low Alarm threshold Read / Write 16 Sensor enable / disable Disable if not required Read / Write Rev. 3.2 Page 20

21 17 Consecutive delay before alarm Value must be between 1 & 254, total Read / Write 18 Total delay before alarm delay must be higher. Read / Write 19 Interval between each reading 5 seconds to 17H:59M:59S Read / Write 20 Start the logger with timer At pre-defined date and time Read / Write 21 Select the start delay DD:HH:MM format Read / Write 22 Show Alarms on the display (options available only for loggers with Read / Write 23 Show temperature on the display LCD) Read / Write 24 Enable alarms Any, all or none Enable / Disable 25 Duration of the trip User defined or choose from list Read / Write 26 Memory used (in previous trip) Read only 27 Stop the logger at pre-defined time (if selected) Read / Write 28 Stop the logger after number of readings have been taken Read / Write 29 Enable stop button (to manually stop the logger) Enable / Disable 30 Battery status Icon (Low or OK battery indicator) Read only 31 Enable non-stop logging (not available for single use loggers) Read /Write (multi use) 32 Auto-reset enabled (not available for single use loggers) Read /Write (multi use) 33 Total time for the designated trip (auto calculated based on the input) Read only Password Protection Multiuse data loggers can be password protected, which allows authorize use of supported loggers. Password can strict program and download functions. Users has also option to use, Program protection Download protection Program and download (both) protection Password policy allows to use numbers from one to five digits and it can be assigned during program (no alphabets are accepted). Initially entire filed is blank and Allow RD / Allow WR are greyed out Allow RD / Allow WR will be available to select as soon as number is entered Pass R/W filed If none of the options, Allow RD / Allow WR is selected, user has to enter password to Program / Download data If Allow RD is selected during program, user can Download the data without password, but not be able to Program If Allow WR is selected during program, user can Program the logger without password, but not be able to Download the data Rev. 3.2 Page 21

22 When logger is connected next time, ConsolePlus ask for a password depending on the option selected, if Allow RD is selected during program, Read Without Password READ button will be highlighted and clickable. After the click Download button will be enabled and data can be downloaded manually by click or if Auto Download is enabled if Allow WR is selected during program, Write Without Password WRITE button will be highlighted and clickable. After the click Program tab will be enabled Pre- defined Settings User can use set of pre-defined settings to program the logger by selecting the list of pre-set no. of days from drop down list. Pre- defined settings Settings of 1 day to 60 day are available. Program will use full memory of the logger and set the time interval between each reading automatically accordingly. Pre-defined settings will overwrite the manual settings of, time interval between each reading and number of total readings Program Template Program settings of a data logger can be saved as program template. Which can be used in future to program the loggers with same settings when needed. The program template will only work with same product code of loggers. To create a template, enter the desired settings on program tab (when the logger is connected) or open a previously saved data file. Save Template Program: From the main menu, click on file and select save program template. A popup window appears linked to default path, where a file name to program template can be assigned. Template will be save with extension *.xtp (ConsolePlus template file). Once the name is assigned press OK. Now this template can be used in future to program one or more loggers with the same settings. Load Template Program: User can use previously saved template (*.xtp) when required. A data logger must be connected to computer (template cannot be loaded if no logger is connected). To use previously saved program template from the main menu, click on file and select load program template. A pop-up window appears linked to default path or can be browsed to the location where the program template is Rev. 3.2 Page 22

23 saved. Once right *.xtp file is located (if multiple *.xtp files exist), select the file and press OK, ConsolePlus application will auto fill all the settings in the fields and will be displayed in red color fonts (as shown) Program lock icon will be locked and program icon will be highlighted as soon as the logger is plugged in and can be programmed with these saved settings Important Note: If a program template is loaded that belongs to a data logger with a different product code, an error will be displayed immediately. Template function is similar to lock program settings function, only difference is, Error message! Lock function works with the same session of programming multiple data loggers (without closing the application). Program template can be used anytime in future Lock Program Settings Lock function/ Template Multiple logger programming made easy with this unique function. Lock function can be accessed from icon bar or from main menu under logger. This function helps to program multiple loggers with the same settings. This function is very similar to program template function. To use this function when the logger is connected, at program tab enter the desired settings for new trip. Once all settings are in place, click the (lock icon) from the icon bar. Most of the parameters (as shown) will change from black to red color and the lock icon will appear as locked. Important Notes: For Lock and template functions: These can only be used with the loggers, which has same product code. If a different logger is detected, lock icon will turn into unlock icon and the red color parameters will turn black. All the settings will be reset. Rev. 3.2 Page 23

24 10.6. Program: Final Confirmation Once the program parameters entered correctly, click program icon. A confirmation dialogue will appear for the final approval. If pressed OK on dialogue box, new program settings will be sent to the logger. Progress bar will quickly grow from 0 to 100%. Depending on the logger type and program settings, loggers will exhibit successful program confirmation. Logger with LCD display may display ready or ready in delay and loggers without LCD will display the LED flash sequence (refer to the logger s user manual for more information). Important Note: Multi use loggers can be programmed with the option to start with timer and/or start button (immediate start or with some delay). Please select these settings carefully as required. In the version or above the progress bar of program will have red fill color, once logger is successfully programmed it will turn green Program confirmation Progress bar - Program Progress bar - Program 11. Download Data of ConsolePlus supported logger can be downloaded easily and very quickly anytime even if the logger is logging or it has stopped logging. Important Notes: iminiusb pdf logger will be stopped automatically when connected to computer. Logger with no data will still be downloaded however the graph, table & histogram will display empty windows, previous program settings can be viewed. Summary will display some information Auto download If the auto download setting is enabled in options, data of a logger will be automatically download when connected to computer and ConsolePlus is launched (refer to section 6.1.2) Manual download: If auto download is disabled, the detected logger will display information Logger/file list and greyed out download icon will be enabled. User can click the icon to downloaded data of connected logger. Depending on the memory size of the logger and size of stored data it can take few seconds to few minutes (for 128K memory loggers). Progress bar will grow for the download status. As soon as the data is retrieved, by default graph tab will appear and a graphical view of data will be displayed. Now all the disabled tabs will be enabled. Data can be viewed (graph, histogram, table, summary, program settings), saved in different formats and also can be analyzed. Rev. 3.2 Page 24

25 12. Graph For quick overview graphical representation of downloaded data or if a supported *.cvt file is opened. Add comment here Logger s S. No. & Product Code Mouse cursor with tool tip Bookmarks Y-axis: Temperature / Humidity X-axis: Date & Time Active sensors & their assigned colors In the add comment section user can add/edit comments as needed, these comments can be saved in *.cvt and *.pdf file and viewed lator X-axis is always Date & Time axis Y-axis is Temperature or Temperature/Humidity (depending on the data logger type) If the logger is with one sensor, graph will display different colors in background at respective alarm range If the logger is multi-sensor, by default background is light blue (as above), settings can always be changed at any time Options " View Tab Graph Legend area has all the sensors available with respective information (S.No. & sensor) User can click each or any of these bullets to select / deselect that particular sensor in the graph. Graph will change accordingly in real time If only one sensor at a given time is selected, the background will display colors based on alarm conditions (HH, H, L, LL) Rev. 3.2 Page 25

26 High High High Low Low Low Colored Background available When one sensor selected Mouse Zoom: User can select some area in graph and it will zoom to the range for closer look Mouse Tool Tip: Hovering the mouse over the graph will show the reading no., time and data information in entire graph 13. Save/ save as If AUTO SAVE is checked in options, the data file will be saved automatically in default folder or user can manually save the data from the icon or from MENU " File " Save/save as Save: by default extension *.CVT in default folder Save as: user can choose extension from drop down list *.CVT, *.TXT, *.CSV Or as PDF file, by default (PDF icon ) saves in default directory Rev. 3.2 Page 26

27 Above options can be selected to auto save different file types, this feature helps users to not to lose the data. 14. Auto- open PDF ConsolePlus generates PDF automatically if selected in options " auto save PDF. If the next option " auto open PDF is enabled, generated PDF will open automatically as soon as the logger is connected and data is downloaded. Adobe PDF applications must be installed on the computer. If Adobe PDF is not installed, user may receive a message during installation of ConsolePlus. If not installed, option " auto open PDF will be permanently greyed out / disabled. Until the Adobe PDF is installed 15. Histogram Analytical view of the data is displayed Rev. 3.2 Page 27

28 16. Table All the data from the logger (from START to FINISH of the current/last trip) can be viewed here. Scroll down to view all the data of the logger. Readings are in colored fonts according to alarm settings triggered to make them easier to understand and detect. Below LOW LOW alarm Dark Blue color Readings within specification GREEN color Below HIGH alarm Light RED color Below LOW alarm Light BLUE color Above HIGH HIGH alarm Dark RED color Rev. 3.2 Page 28

29 17. Summary Detailed summary of the trip and basic information of the logger and all sensors can be viewed here Basic Summary Internal Temp (Digital) Or NTC (or Ext Left) (if not with Humidity sensor) Internal Humidity (Digital) External Temp NTC (Ext Right) 1M Grey Cable Rev. 3.2 Page 29

30 18. Bookmark A Bookmark displays a MARKED reading, users can mark a reading during the logging by briefly holding START button on the logger for 3-5 seconds, MARKED text displayed on the LCD display of the logger screen for few seconds, and that reading is marked with time stamp Once data is downloaded Graph view, a STAR is placed at the time and reading Bookmarked readings Table view, bookmarked readings are highlighted with grey background Bookmarked readings Rev. 3.2 Page 30

31 19. MKT User can view Mean Kinetic Temperature; on summary tab. Mean kinetic temperature (MKT) is a simplified way of expressing the overall effect of temperature fluctuations during storage or transit of perishable goods Activation energy (typically within kj mol - 1 for solids or liquids), ConsolePlus allow users to customize activation energy. This option is available in Options / settings on general tab 20. Multilink User is allowed to link multiple files (with extension CVT) by selecting with mouse or by pressing shift and selecting individual files. Compare the results with different options. I. Compare trip data based on actual date/time of each reading II. Compare trip data from different date/time period(s) The linked files also can be saved into TXT and CSV format for further evaluation or to print. Data from multiple files also reflects in Graph, Histogram, Table and Summary I. Compare trip data based on actual date/time of each reading Rev. 3.2 Page 31

32 Rev. 3.2 Page 32

33 Rev. 3.2 Page 33

34 II. Compare trip data from different date/time period(s) Rev. 3.2 Page 34

35 Rev. 3.2 Page 35

36 21. Battery Status Logger s battery status is directly displayed on program tab. Software can detect the status and report with icon OK battery Low battery If the data logger has low battery, low battery symbol is displayed on LCD of the data logger (if logger supports LCD) 22. Print / Print- preview Print / Print- preview functions are available in ConsolePlus, when a file is open or logger is connected and downloaded. Available in main menu and icons are at the top of the application 23. Update ConsolePlus software will check for updates automatically and will display a confirmation message when application is launched. Also it can be easily updated manually from MENU tab, by selecting check for update. So user need not to download a separate file all the time. Rev. 3.2 Page 36

37 1. Launch ConsolePlus application 2. If computer is connected to internet and an update is available. A pop-up will appear to notifying that update is available. 3. Press OK to accept the upgrade 4. Usually the software starts upgrade immediately 5. Or a pop-up window appears 6. After pressing OK Software starts upgrade or Depending on the user account privileges and firewall settings, user may encounter unresponsive upgrade 7. In the event of non-responsive upgrade, CANCEL the upgrade and re-launch ConsolePlus 8. Now deselect Protect my computer and data from unauthorized program activity 9. Now press OK 10. Upgrade should be successful 11. In the event of further issues, user can download latest software by clicking the following link directly. For more information about product and applications please contact techsupport@cryopak.com Rev. 3.2 Page 37

ESCORT ConsolePlus (EA-SWP-PLUS) User Manual Ver. 3.1

ESCORT ConsolePlus (EA-SWP-PLUS) User Manual Ver. 3.1 ESCORT ConsolePlus (EA-SWP-PLUS) User Manual Ver. 3.1 Console Plus User Manual version 3.1 Page 1 Contents 1. Quick start Guide... 3 2. Dependences... 4 3. Accessories... 4 4. Installation... 5 5. Introduction...

More information

KeyTag Manager User Guide. Release /02/2017

KeyTag Manager User Guide. Release /02/2017 KeyTag Manager KeyTag Manager User Guide. Release 009 18/02/2017 KeyLog Recorders Copyright 2017 1 Table of Contents 1. Table of Contents 2. PRESENTATION & INSTALLATION:...4 2.1. INTRODUCTION TO KEYTAG

More information

zloggmanager User Guide Release /12/2018

zloggmanager User Guide Release /12/2018 zlogg zloggmanager User Guide Release 011 02/12/2018 zlogg Copyright 2017 http://z-logg.com 1 Table of Contents 1. Table of Contents 2. PRESENTATION AND INSTALLATION:...4 2.1. INTRODUCTION TO ZLOGGMANAGER...4

More information

DwyerLog Logger Interface Software

DwyerLog Logger Interface Software DwyerLog Logger Interface Software USER S GUIDE Version 1.4x March 21, 2013 Dwyer Instruments, Inc 102 Indiana Hwy 212 Michigan City, IN 46360 Phone: (219) 879-8868 Fax: (219) 872-9057 http://www.dwyer-inst.com

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

First Edition Termologger USB & OSAKA MicroLab Lite User guide

First Edition Termologger USB & OSAKA MicroLab Lite User guide First Edition Termologger USB & OSAKA MicroLab Lite User guide First Print February 2007 Introduction The Termologger USB is a compact 16-bit USB data logger designed for accurate temperature monitoring

More information

MicroLite & MicroLab Lite User Guide. First Edition First Print February 2007 Fourier Systems Ltd.

MicroLite & MicroLab Lite User Guide. First Edition First Print February 2007 Fourier Systems Ltd. MicroLite & MicroLab Lite User Guide First Edition First Print February 2007 Fourier Systems Ltd. Contents Introduction... 1 Chapter 1 Using the MicroLite... 2 1.1. Overview... 3 1.2. Getting Started...

More information

Desktop & Laptop Edition

Desktop & Laptop Edition Desktop & Laptop Edition USER MANUAL For Mac OS X Copyright Notice & Proprietary Information Redstor Limited, 2016. All rights reserved. Trademarks - Mac, Leopard, Snow Leopard, Lion and Mountain Lion

More information

PV101-C Configuration Software V3.2. Installation and Operations Manual Section 78

PV101-C Configuration Software V3.2. Installation and Operations Manual Section 78 PV101-C Configuration Software V3.2 Installation and Operations Manual 00-02-0797 08-18-11 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right

More information

Operating Manual. Version 7.3.4

Operating Manual. Version 7.3.4 Operating Manual Version 7.3.4 March 2011 Index Page 1. Installation instructions 4 1.1 System requirements 4 1.2 Installation procedure 4 1.3 Meitav-tec USB adaptor installation 7 2. Open Maxinet and

More information

DataNet Installation Guide + Quick Start Guide Updated: August 2008

DataNet Installation Guide + Quick Start Guide Updated: August 2008 DataNet Installation Guide + Quick Start Guide Updated: August 2008 This document contains instructions for downloading and installing the DataNet software, supporting Fourier Systems DataNet data logging

More information

BackupVault Desktop & Laptop Edition. USER MANUAL For Microsoft Windows

BackupVault Desktop & Laptop Edition. USER MANUAL For Microsoft Windows BackupVault Desktop & Laptop Edition USER MANUAL For Microsoft Windows Copyright Notice & Proprietary Information Blueraq Networks Ltd, 2017. All rights reserved. Trademarks - Microsoft, Windows, Microsoft

More information

Copyright. Copyright LogTag Recorders. All rights reserved.

Copyright. Copyright LogTag Recorders. All rights reserved. 2.0 Copyright The information contained within this document regarding LogTag Analyzer software usage is intended as a guide and does not constitute a declaration of performance. The information contained

More information

N2KExtractor. NMEA 2000 Data Extractor Software. User s Manual

N2KExtractor. NMEA 2000 Data Extractor Software. User s Manual N2KExtractor NMEA 2000 Data Extractor Software User s Manual Revision 1.0.0 Copyright 2012 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

DataSuite User Guide. Supporting: DataNet, DaqLink, MicroLite, MicroLogPRO II, PicoLite. FDA Title 21 CFR Part 11 Compliant.

DataSuite User Guide. Supporting: DataNet, DaqLink, MicroLite, MicroLogPRO II, PicoLite.   FDA Title 21 CFR Part 11 Compliant. ourtec FOURIERTECHNOLOGIES FDA Title 21 CFR Part 11 Compliant www.kongsgaarden.no www.fourtec.com www.fourtec.com DataSuite User Guide Supporting: DataNet, DaqLink, MicroLite, MicroLogPRO II, PicoLite

More information

IMS Client Operation Guide Version V1.1 Date

IMS Client Operation Guide Version V1.1 Date Version V1.1 Date 2015-10-20 About This Document About This Document About This User Manual Please note the following points before using this user manual: This user manual is intended for persons who

More information

User Manual PDUTracker

User Manual PDUTracker User Manual PDUTracker Management Software for PDU Table of Contents 1. Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software

More information

Datalogger Graph Software Help

Datalogger Graph Software Help Datalogger Graph Software Help Version 1.2, March 9, 2007 For additional information refer to the user guide included on the supplied program disk. CONTENTS Quick Start Guide Installing Graph Software

More information

N2KExtractor. Maretron Data Extraction Software User s Manual

N2KExtractor. Maretron Data Extraction Software User s Manual N2KExtractor Maretron Data Extraction Software User s Manual Revision 3.1.6 Copyright 2017 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

Central Management Software. Cam Viewer 3 Lite. User Manual

Central Management Software. Cam Viewer 3 Lite. User Manual Central Management Software Cam Viewer 3 Lite User Manual Version 1.0.0 Table of Contents 1. System Requirement...4 2. Software Installation...5 3. Configuration Wizard...9 3.1 Channel...10 3.1.1 Adding

More information

User Manual. Thermo Scientific Orion

User Manual. Thermo Scientific Orion User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation

More information

Instructions for MX350 Firmware Upload

Instructions for MX350 Firmware Upload Instructions for MX350 Firmware Upload MX350 Document AN10048 Page 1 of 39 Contents Section Description Page 1 Requirements 3 2 Install MX350 Setup Software 3 3 Download MX350 Firmware 4 4 Connect MX350

More information

#61-844SW ThermalVision Software Instruction Manual

#61-844SW ThermalVision Software Instruction Manual ThermalVision Software Instruction Manual ND-7035-1 Page 1 of 23 Contents 1. Installing the ThermalVision software onto a PC... 3 2. Transferring saved images from the camera to the PC.... 3 2.1. Direct

More information

IGSS 13 Configuration Workshop - Exercises

IGSS 13 Configuration Workshop - Exercises IGSS 13 Configuration Workshop - Exercises Contents IGSS 13 Configuration Workshop - Exercises... 1 Exercise 1: Working as an Operator in IGSS... 2 Exercise 2: Creating a new IGSS Project... 28 Exercise

More information

GX-2009 Data Logger Management Program Operator s Manual

GX-2009 Data Logger Management Program Operator s Manual GX-2009 Data Logger Management Program Operator s Manual Part Number: 71-0163RK Revision: P1 Released: 4/30/09 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by

More information

Contents. Contents... 1 Introduction... 4 An Overview of HOBOware... 4

Contents. Contents... 1 Introduction... 4 An Overview of HOBOware... 4 Contents Contents... 1 Introduction... 4 An Overview of HOBOware... 4 Installing HOBOware... 6 Installing HOBOware or HOBOware Pro from the Onset Website... 6 Installing HOBOware Pro from the Installation

More information

Contents. Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA Contents Introduction... 3 An Overview of HOBOware...

Contents. Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA Contents Introduction... 3 An Overview of HOBOware... Contents Contents... 1 Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA 02532 Introduction... 3 An Overview of HOBOware... 3 Installing HOBOware... 5 Installing HOBOware or HOBOware Pro from the

More information

DriveWizard Plus Instruction Manual

DriveWizard Plus Instruction Manual DriveWizard Plus Instruction Manual To properly use the product, read this manual thoroughly. MANUAL NO. TOEP C730600 20C Table of Contents Safety Symbols and Markings...4 Manual Overview...5 Related Manuals...5

More information

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel v3.1.4 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER...2 1.1 CONTROLLER...2 1.2 SPECIFICATIONS AND FEATURES...3 CHAPTER

More information

EVOBOOK 2. User s Manual.

EVOBOOK 2. User s Manual. EVOBOOK 2 User s Manual www.evolio.ro 0 User s Manual Content Page Introduction.... 2 Parts and Controls.... 3 Getting Started...... 6 Turning On/Off EvoBook2. 6 Charging EvoBook2... 6 Inserting SD card....

More information

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel v3.1.4 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 2 1.1 CONTROLLER... 2 1.2 SPECIFICATIONS AND FEATURES... 3 CHAPTER

More information

Creating Interactive PDF Forms

Creating Interactive PDF Forms Creating Interactive PDF Forms Using Adobe Acrobat X Pro for the Mac University Information Technology Services Training, Outreach, Learning Technologies and Video Production Copyright 2012 KSU Department

More information

User Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2

User Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2 User Manual MPPTracker Management Software for Solar Charge Controller Version: 1.2 Table of Contents 1. MPPTracker Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. MPPTracker Install and Uninstall...

More information

How to install the software of ZNS8022

How to install the software of ZNS8022 How to install the software of ZNS8022 1. Please connect ZNS8022 to your PC after finished assembly. 2. Insert Installation CD to your CD-ROM drive and initiate the auto-run program. The wizard will run

More information

testo Comfort Software Professional 4 Instruction manual

testo Comfort Software Professional 4 Instruction manual testo Comfort Software Professional 4 Instruction manual 2 1 Contents 1 Contents 1 Contents...3 2 About this document...5 3 Specifications...6 3.1. Use...6 3.2. System requirements...6 4 First steps...7

More information

NetBrain Technologies Inc. NetBrain Consultant Edition. Quick Start Guide

NetBrain Technologies Inc. NetBrain Consultant Edition. Quick Start Guide NetBrain Technologies Inc. NetBrain Consultant Edition Quick Start Guide Content 1. Install NetBrain Workstation CE System... 3 1.1 Install and Activate NetBrain Gateway Server... 5 1.2 Install Workstation...

More information

testo Comfort Software Professional 4 Instruction manual

testo Comfort Software Professional 4 Instruction manual testo Comfort Software Professional 4 Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 About this document... 5 3 Specifications... 6 3.1. Use... 6 3.2. System requirements... 6 4 First steps...

More information

Server Edition USER MANUAL. For Microsoft Windows

Server Edition USER MANUAL. For Microsoft Windows Server Edition USER MANUAL For Microsoft Windows Copyright Notice & Proprietary Information Redstor Limited, 2016. All rights reserved. Trademarks - Microsoft, Windows, Microsoft Windows, Microsoft Windows

More information

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems ViewPower User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview...2 1.1. Introduction...2 1.2. Structure...2 1.3. Applications...2 1.4. Features...3

More information

SolarPower Pro. User s Manual. Management Software for Solar Inverter

SolarPower Pro.  User s Manual. Management Software for Solar Inverter SolarPower Pro User s Manual Management Software for Solar Inverter Table of Contents 1. SolarPower Pro Overview... 2 1.1. Introduction... 2 1.2. Structure... 2 1.3. Features... 3 2. SolarPower Pro Install

More information

TouchScreen for Display & Panel-PC

TouchScreen for Display & Panel-PC TouchScreen for Display & PanelPC User Manual for Windows 2000 / XP Version: 4.0.2 TouchKit Manual for Win2000/XP v4.0.2 Page 1 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 3 1.1 CONTROLLER... 3 1.2 SPECIFICATIONS

More information

DCMS. User Manual. Version V1.0

DCMS. User Manual. Version V1.0 DCMS User Manual Version V1.0 About This Document About This Document About This User Manual Please note the following points before using this user manual: This user manual is intended for persons who

More information

Before starting installation process, make sure the USB cable is unplugged.

Before starting installation process, make sure the USB cable is unplugged. Table of contents 1 Introduction...4 2 Software installation...4 2.1 Minimum configuration required...4 2.2 Software installation on Windows 7 / Vista / 8...4 2.3 Software installation on Windows XP...4

More information

Table of Contents.

Table of Contents. Table of Contents 1. Items Included with the BioAxxis ThumbLock Audit Trail Software: 2 2. IMPORTANT NOTE:... 2 3. Supported Operating Systems:... 3 Section 1 Installing the BioAxxis ThumbLock AT Software...

More information

ATX Document Manager. User Guide

ATX Document Manager. User Guide ATX Document Manager User Guide ATX DOCUMENT MANAGER User Guide 2008 CCH Small Firm Services. All rights reserved. 6 Mathis Drive NW Rome, GA 30165 No part of this manuscript may be copied, photocopied,

More information

INSTALLING THE PS3 XBOX READY SOFTWARE:

INSTALLING THE PS3 XBOX READY SOFTWARE: INSTALLING THE PS3 XBOX READY SOFTWARE: 1. Insert the Installation CD to CD-ROM drive and execute Ready_Setup.exe NOTE: If it is the first time for the target USB disk using under this software, the software

More information

TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0

TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0 TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0 1 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER 2 1.1 Controller 2 1.2 Specifications and Features 3 CHAPTER 2. INSTALLING TOUCHKIT

More information

testo Comfort Software Professional 4

testo Comfort Software Professional 4 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo Comfort Software Professional 4 Instruction manual 1 Contents 1 Contents

More information

Quick Start Guide - Contents. Opening Word Locating Big Lottery Fund Templates The Word 2013 Screen... 3

Quick Start Guide - Contents. Opening Word Locating Big Lottery Fund Templates The Word 2013 Screen... 3 Quick Start Guide - Contents Opening Word... 1 Locating Big Lottery Fund Templates... 2 The Word 2013 Screen... 3 Things You Might Be Looking For... 4 What s New On The Ribbon... 5 The Quick Access Toolbar...

More information

Table of Contents.

Table of Contents. Table of Contents http://www.advancedactuators.com 1. Items Included with the ThumbLock PCMU:... 2 2. IMPORTANT NOTE:... 2 3. Supported Operating Systems:... 2 Section 1 Installing the ThumbLock PCMU Software...

More information

Drulo Control Operating Instructions. Version and higher

Drulo Control Operating Instructions. Version and higher Drulo Control Operating Instructions Version 1.0.1.2 and higher Contents Operating Instructions Drulo Control... 1 Version 1.0.1.2 and higher... 1 Contents... 2 List of illustrations... 4 Contact details...

More information

Committed to Quality. MicroLogPRO Solution. User Guide

Committed to Quality. MicroLogPRO Solution. User Guide Committed to Quality MicroLogPRO Solution User Guide MicroLogPRO & MicroLog Plus User Guide Third Edition First Print April 2007 Fourier Systems Ltd. Contents Using the Guide... 1 Compliance with FDA

More information

Applied ICT Skills MS Windows

Applied ICT Skills MS Windows Applied ICT Skills MS Windows Lesson 1 - How to install an operating system into computer? Windows 7 is perhaps the best Microsoft operating system and is very easy to install compared to other windows.

More information

Track-It User s Guide. 1. Table of Contents. Track-It User Guide

Track-It User s Guide. 1. Table of Contents. Track-It User Guide Track-It User s Guide Track-It is a PC based (Windows XP / Vista/ Windows 7) program to enable a user to program and view data from the Track-It series of micro data loggers. The program allows the loggers

More information

Server Edition USER MANUAL. For Mac OS X

Server Edition USER MANUAL. For Mac OS X Server Edition USER MANUAL For Mac OS X Copyright Notice & Proprietary Information Redstor Limited, 2016. All rights reserved. Trademarks - Mac, Leopard, Snow Leopard, Lion and Mountain Lion are registered

More information

TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1

TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1 TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1 TouchKit Guide for WinNT4 v3.2.1 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 2 1.1 CONTROLLER... 2 1.2 SPECIFICATIONS AND FEATURES...

More information

Server Edition. V8 Peregrine User Manual. for Microsoft Windows

Server Edition. V8 Peregrine User Manual. for Microsoft Windows Server Edition V8 Peregrine User Manual for Microsoft Windows Copyright Notice and Proprietary Information All rights reserved. Attix5, 2015 Trademarks - Microsoft, Windows, Microsoft Windows, Microsoft

More information

Configuration of trace and Log Central in RTMT

Configuration of trace and Log Central in RTMT About Trace Collection, page 1 Preparation for trace collection, page 2 Types of trace support, page 4 Configuration of trace collection, page 5 Collect audit logs, page 19 View Collected Trace Files with

More information

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151 USER S MANUAL Contents 1. Main Features... 4 A Variety of Display Formats...4 Simple and Easy to Use...5 Thumbnail Waveform Display...5 Export to Direct Excel File Function...6 CSV File Batch Conversion...6

More information

SUMMARY. Minimum required configuration... Software installation... User logo customisation... Software Un-installation... Launching application...

SUMMARY. Minimum required configuration... Software installation... User logo customisation... Software Un-installation... Launching application... 1 SUMMARY I. Installation procedure...3 A B C D E Minimum required configuration... Software installation... User logo customisation... Software Un-installation... Launching application... 3 3 3 3 3 II.

More information

EU Driver s Hours Rules covered by Digifobpro. Table of contents

EU Driver s Hours Rules covered by Digifobpro. Table of contents EU Driver s Hours Rules covered by Digifobpro Digifobpro provides analysis of Driver Cards both in it s Quick View and Driver Card - Download features ( see Digifobpro Functions page 4). There follows

More information

Lorex Client 7.0 & Lorex Message Master

Lorex Client 7.0 & Lorex Message Master Lorex Client 7.0 & Lorex Message Master Software Manual English Version 1.0 MODELS: L19WD Series www.lorexcctv.com Includes L19WD800 & L19WD1600 Copyright 2008 Lorex Technology Inc. Table of Contents Table

More information

User Manual Portable Laptop Console Crash Cart Adapter

User Manual Portable Laptop Console Crash Cart Adapter User Manual Portable Laptop Console Crash Cart Adapter GUC211V PART NO. M1458 www.iogear.com 2017 IOGEAR. All Rights Reserved. Part No. M1458. IOGEAR, the IOGEAR logo is trademarks of IOGEAR. Microsoft

More information

User Guide. K V1 7/05 Rev A

User Guide. K V1 7/05 Rev A NAVIGATOR REPORTER User Guide K10321-1V1 7/05 Rev A Table of Contents Conventions Used in This Manual... iii SECTION 1: General Description... 1-1 About Navigator Reporter...1-1 About User Manager...1-1

More information

SC-01 Data Logger Management Program Operator s Manual

SC-01 Data Logger Management Program Operator s Manual SC-01 Data Logger Management Program Operator s Manual Part Number: 71-0138RK Revision: P1 Released: 9/12/07 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by

More information

Exhibitor Software User s Manual. Exhibitor Software V

Exhibitor Software User s Manual. Exhibitor Software V Exhibitor Software User s Manual Exhibitor Software V1.0.1 090908 1 Contents 1. Exhibitor Software 2. Installation 3. Using Exhibitor Program 3.1 Starting the Program 3.2 Logging in to the Program 3.3

More information

Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set

Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set Updates to the instrument firmware are available from the Applied Instruments website. Requirements

More information

DVR 528 Digital Video Camera

DVR 528 Digital Video Camera DVR 528 Digital Video Camera User Manual 2010 Sakar International, Inc. All rights reserved. Windows and the Windows logo are registered trademarks of Microsoft Corporation. All other trademarks are the

More information

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit Axxis Biometrics LLC BioAxxis L113 Fingerprint Door Lock Programming Kit Revision 0.14 Dec 2005 Table of Contents 1. Introduction... 2 Product Overview... 2 Main Features... 2 Packing Lists... 3 2. Operation

More information

Firmware, Database, & PC Application Update Installation Instructions

Firmware, Database, & PC Application Update Installation Instructions Firmware, Database, & PC Application Update Installation Instructions IMPORTANT Please read before you begin the installation. To avoid possible errors, it is recommended to install the updates as described

More information

NVMS User Manual. Version 2.1.0

NVMS User Manual. Version 2.1.0 NVMS-1000 User Manual Version 2.1.0 Contents 1 Software Introduction... 1 1.1 Summary... 1 1.2 Operation Environment... 1 1.3 Install and Uninstall... 2 1.3.1 Install the Software... 2 1.3.2 Uninstall

More information

Password Memory 7 User s Guide

Password Memory 7 User s Guide C O D E : A E R O T E C H N O L O G I E S Password Memory 7 User s Guide 2007-2018 by code:aero technologies Phone: +1 (321) 285.7447 E-mail: info@codeaero.com Table of Contents How secure is Password

More information

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter Updates to the Field Guide and to the instrument firmware are available from the Applied Instruments website.

More information

version 7.6 user manual

version 7.6 user manual version 7.6 user manual 2 Copyright JAVS 1981-2014 Table of Contents Introduction... 4 Getting Started... 5 Login... 5 JAVS Publisher 7 Overview... 6 Search Tool Overview... 7 Search Tool-Detailed Operation...

More information

Using MDC Manager to Manage Power Settings

Using MDC Manager to Manage Power Settings AddendumA Using MDC Manager to Manage Power Settings This addendum explains how to use the MDC Manager to configure and manage the power settings for the M7. It is organized into the following sections:

More information

VANGUARD LOAD TAP CHANGER ANALYZER (LTCA) VERSION 2.xx SOFTWARE MANUAL. LTCA-10, LTCA-40, WRM-10P, WRM-40, TRM-20, TRM-40, TRM-203, and TRM-403

VANGUARD LOAD TAP CHANGER ANALYZER (LTCA) VERSION 2.xx SOFTWARE MANUAL. LTCA-10, LTCA-40, WRM-10P, WRM-40, TRM-20, TRM-40, TRM-203, and TRM-403 VANGUARD LOAD TAP CHANGER ANALYZER (LTCA) VERSION 2.xx SOFTWARE MANUAL For Use with Vanguard s LTCA-10, LTCA-40, WRM-10P, WRM-40, TRM-20, TRM-40, TRM-203, and TRM-403 Load Tap Changer Analyzers and Winding

More information

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series INSTALLATION & OPERATING GUIDE Rev. B P/N 3321515 www.securakeystore.com (800) 878-7829 sales@securakeystore.com COPYRIGHT 2001

More information

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 User Guide Model 42265 Temperature Datalogger Kit Model 42275 Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 Introduction Congratulations on your purchase of Extech Instrument

More information

Expedient User Manual Getting Started

Expedient User Manual Getting Started Volume 1 Expedient User Manual Getting Started Gavin Millman & Associates Pty Ltd 281 Buckley Street Essendon VIC 3040 Phone 03 9331 3944 Web www.expedientsoftware.com.au Table of Contents Logging In...

More information

Apptix Online Backup by Mozy User Guide

Apptix Online Backup by Mozy User Guide Apptix Online Backup by Mozy User Guide 1.10.1.2 Contents Chapter 1: Overview...5 Chapter 2: Installing Apptix Online Backup by Mozy...7 Downloading the Apptix Online Backup by Mozy Client...7 Installing

More information

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str. FLOWgate500 Software Manual Software Manual FLOWgate500 Release 2.2 Revision number: V2.2 Manufacturer: SICK AG Erwin-Sick-Str.1 D-79183 Waldkirch Germany Place of manufacture: SICK Engineering GmbH Bergener

More information

USB Temperature Logger User Guide

USB Temperature Logger User Guide PR0455 For Products: - PR0710, PR0711, PR0720, PR0721 Resource Data Management Ltd 80 Johnstone Avenue, Hillington Industrial Estate, Glasgow, Scotland, G52 4NZ, UK +44(0)141 810 2828 Switchboard support@resourcedm.com

More information

The Fundamentals. Document Basics

The Fundamentals. Document Basics 3 The Fundamentals Opening a Program... 3 Similarities in All Programs... 3 It's On Now What?...4 Making things easier to see.. 4 Adjusting Text Size.....4 My Computer. 4 Control Panel... 5 Accessibility

More information

AST2500 ibmc Configuration Guide

AST2500 ibmc Configuration Guide AST2500 ibmc Configuration Guide Version 1.0b Copyright Copyright 2017 MITAC COMPUTING TECHNOLOGY CORPORATION. All rights reserved. No part of this manual may be reproduced or translated without prior

More information

Connected to the FP World

Connected to the FP World Connected to the FP World User Manual 2 mailcredit User Manual About this manual Target group Topics mailcredit.exe [Next] The User Manual of mailcredit is primarily aimed at users of FP franking machines

More information

9936A LogWare III. User s Guide. Revision

9936A LogWare III. User s Guide. Revision 9936A LogWare III User s Guide Revision 850701 Table of Contents 1 Introduction...1 1.1 Symbols Used... 1 1.2 Conventions... 1 1.3 What is LogWare?... 1 1.4 License Agreement... 2 1.5 Requirements...

More information

Mini Mini GlobiLab Software Quick Start Guide

Mini Mini GlobiLab Software Quick Start Guide Mini Mini GlobiLab Software Quick Start Guide This Guide is intended to help you get your Mini up and running quickly. For more detailed instructions, please see the Getting to Know Your Mini document

More information

Wimba Classroom Version 6.1 Room Administrator Guide

Wimba Classroom Version 6.1 Room Administrator Guide Wimba Classroom Version 6.1 Room Administrator Guide Wimba Classroom 6.1 Room Administrator Guide 1 Administration Tools 2 Room Management 3 Creating a New Room (RoomCreators Only) 3 Setting up a Room

More information

RF-Monitor B User's Guide

RF-Monitor B User's Guide www.loggerteknik.se Newsteo RF-Monitor B User's Guide for Monitoring Logger Version 1.2 TEL 031-760 60 16 Phone int. +46 31 760 60 16 Purpose User guide for Newsteo RF-Monitor B v3.0.7 Technical support

More information

INSIGHT Installation Instructions

INSIGHT Installation Instructions This is the New Icon that will appear on your computer screen after the INSIGHT v8.1 software is installed. IMPORTANT: These instructions pertain to version 8.1.29. INSIGHT v8.1.29 requires Windows 8,

More information

TEXET SIM USB. (Instruction Manual)

TEXET SIM USB. (Instruction Manual) TEXET SIM USB (Instruction Manual) Thank you for purchasing this SIM card reader. Please read this manual carefully to ensure you understand the operation and keep it for future reference. The information

More information

Forms/Distribution Acrobat X Professional. Using the Forms Wizard

Forms/Distribution Acrobat X Professional. Using the Forms Wizard Forms/Distribution Acrobat X Professional Acrobat is becoming a standard tool for people and businesses to use in order to replicate forms and have them available electronically. If a form is converted

More information

testo Comfort Software Basic 5

testo Comfort Software Basic 5 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo Comfort Software Basic 5 Instruction manual 2 1 Contents 1 Contents 1 Contents...

More information

IS2000. Administrative Operator s Guide. AOG-101 (07/2005) Software Version 7.45

IS2000. Administrative Operator s Guide.  AOG-101 (07/2005) Software Version 7.45 IS2000 Administrative Operator s Guide www.imron.com AOG-101 (07/2005) Software Version 7.45 Table of Contents INTRODUCTION...6 Overview...6 GENERAL INFORMATION...6 Logging On...7 Logging Off...9 Event

More information

Storage Security Software (Version )

Storage Security Software (Version ) For Toshiba CANVIO series Storage Security Software (Version 1.00.6904) User s Manual Version 1.00 This document explains the installation process and basic usage of the Storage Security Software designed

More information

TouchKit Touch Panel User manual for Windows9X/ME Version: 3.1.4

TouchKit Touch Panel User manual for Windows9X/ME Version: 3.1.4 TouchKit Touch Panel User manual for Windows9X/ME Version: 3.1.4 TouchKit Touch Panel v3.1.4 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 2 1.1 CONTROLLER... 2 1.2 SPECIFICATIONS AND FEATURES... 3 CHAPTER

More information

TempLog & RH/TempLog User Guide. Sixth Edition First print Printed in July

TempLog & RH/TempLog User Guide. Sixth Edition First print Printed in July TempLog & RH/TempLog User Guide Sixth Edition First print Printed in July 2003 www.4oakton.com Contents Using the Guide... 15 Chapter 1 OaktonLog... 17 1.1. Overview... 18 1.2. Getting Started... 19 1.3.

More information

ForeScout Extended Module for Tenable Vulnerability Management

ForeScout Extended Module for Tenable Vulnerability Management ForeScout Extended Module for Tenable Vulnerability Management Version 2.7.1 Table of Contents About Tenable Vulnerability Management Module... 4 Compatible Tenable Vulnerability Products... 4 About Support

More information

DOWNLOAD KIT CYCLOCOMPUTER INTRODUCTION. Download unit & Download Software [e-train Data Ver.3] for Windows 98/ME/2000/XP

DOWNLOAD KIT CYCLOCOMPUTER INTRODUCTION. Download unit & Download Software [e-train Data Ver.3] for Windows 98/ME/2000/XP CYCLOCOMPUTER Download unit & Download Software [e-train Data Ver.3] for Windows 98/ME/2000/XP 0365510 (ENG) 3 INTRODUCTION The CC-TR100 Download Kit contains the software e-train Data TM Ver. 3 and the

More information

suitedxt Instructions for Use NeoSoft, LLC NS Rev. 2 Copyright 2014 NeoSoft, LLC All rights reserved

suitedxt Instructions for Use NeoSoft, LLC NS Rev. 2 Copyright 2014 NeoSoft, LLC All rights reserved suitedxt Instructions for Use NeoSoft, LLC NS 03 009 0001 Rev. 2 Copyright 2014 NeoSoft, LLC All rights reserved Revision History Document Revision Date of Issue Description 1 14 July 2014 Initial Release

More information