Operating Instructions. November 2008 (Subject to technical modifications) PROFESSIONAL. HUMMEL AG Geschäftsbereich EL

Size: px
Start display at page:

Download "Operating Instructions. November 2008 (Subject to technical modifications) PROFESSIONAL. HUMMEL AG Geschäftsbereich EL"

Transcription

1 Operating Instructions November 2008 (Subject to technical modifications) PROFESSIONAL HUMMEL AG Geschäftsbereich EL Robert-Bunsen-Straße Denzlingen Telefon: +49(0)7666/ Fax: +49(0)7666/ Internet:

2 Table of Contents General Information Safety Instructions, Warranty, Intended Use, General Information... 3 Set-Up, Cleaning, Service, Disposal... 4 Controller View of the Device... 5 Controller Board / Repair Load Fuses... 5 Configuration / Controller Board Assignment... 6 Zone / Controller Board Assignment... 7 Soft-Start Ramp... 7 Connections: Load / Thermocouple... 8 Connections: Alarm Connector... 9 Start-Up... 9 Touch Screen Operating Panel Front View Main Functions Display Menu Table Menu Parameter Menu Diagram Menu Utilities Menu System Menu Options Menu Diagnostics Menu LC Operating Panel Front View Alarm Indicators Setpoints, Zones Switch off Function Keys Manual Mode Change Parameters Parameters, Factory Preset PC Operation Specifications Important operating instructions, do not ignore! 2

3 Safety Instructions Please read these operating instructions carefully prior to using the product. The unit may be serviced only by qualified personnel. Be sure to withdraw the mains plug before opening the housing! Never replace the controller cards unless the unit has been disconnected from the power supply. Do only use the same type of fuses, 16 amps FF(See Repair Load Fuses ). Prior to inserting the mold cables, be sure to verify that all connectors have been properly connected (see Connections ). Check power supply cable and mold cables for potential defects on a regular basis! If the cable sheath is found to be defective, be sure to use a new connecting cable! Warranty The manufacturer grants a 2-year warranty for all slide-in controllers, with the period of warranty beginning on the day when the product is dispatched to the buyer. However, the warranty shall not cover damage caused by incorrect handling, wrong connection or improper use (see below). Return goods must be sent to HUMMEL AG, Geschäftsbereich EL Denzlingen, in their original packaging, postage prepaid. Intended Use units are industrial temperature controllers for controlling the melting temperature of hot-runner molds. To this end, the controllers determine the temperature of the respective control zone via a Thermocouple. This input is then used to regulate the power output for the heating element. To prevent overheating damage in case of malfunction, an external temperature fuse must be integrated into the heating circuits. The manufacturer shall not be liable for damage caused by improper use of the device. General Information A separate control zone is required for each load (zone) to be connected. A control zone consists of a temperature sensor input and a load output including a fuse. When connecting the mold cables, be sure to assign the cables to the correct connectors (see Connections ). Unused controller modules must be switched off. A heat-resistant flexible cable must be used as a connecting lead for the load circuits. For the Thermocouple, a special compensating lead is required! Cables are available as original accessories. 3

4 Set-Up Cleaning Service Disposal The device includes built-in, powerful fans that reliably prevent overheating of the output stage during operation. The corresponding ventilation slots are located on the underside and the rear side of the device. Make sure that air supply through these openings is not obstructed! The external surfaces of the device and the operating panel may be cleaned with a soft cloth saturated with alcohol. Please do not use acid cleaners or scouring agents. To prevent malfunction, the operating panel should only be cleaned after the device has been switched off. The device must be regularly subjected to a safety check complying with BGV A2 requirements (protection against accidents). It is recommended to clean the dust filters at regular intervals. Depending on the operating period and working condition, the filters should be replaced in the cassette. In addition, the ventilation slots should be checked for obstruction and cleaned if necessary. However, this task must be carried out by qualified service personnel and not by the user. No other maintenance work is required for the device beyond the tasks specified above. Should malfunction occur, please contact the manufacturer. Once the device has reached the end of its service life, please feel free to return it to the manufacturer for proper disposal. This device satisfies the essential protection requirements specified in pertinent EU Directives (as of 2005) 4

5 View of the Device Front side Controller board 1 Rear side Operating panel connector Interface connector Alarm connector Main switch Thermocouple connectors Load connector Power supply cable Controller board 16 Controller Board with Load Fuses l k j i h g f e d c b a IMPORTANT NOTICE: Any work to be performed on the device may only be carried out by qualified personnel. Be sure to pull the mains plug before removing controller board(s)! To replace fuses, unlock the corresponding controller board (rotate the 4 locks by 90 ), then withdraw board. Be sure to use replacement fuses of the same type (16 A FF)! The controller boards are designed for 6 zones. For assignment, refer to the Zone / Controller Board Assignment section. 5

6 Configuration Address-Settings The best method of configuring the replacement card is by transferring the settings of the original card. The card number is the card address to be set. By using the Hex-switch (As shown in fig. 1) close to the processor IC, the address can be selected, e.g. card 1 (Zone 1-6) is to be set to address 1, card 2 (Zone 7-12) to address 2 etc. A b L e i t e r p la t t e n v e r s i o n e n V 1. 3 Abb H E X K a r te 1 O F F O F F O F F O F F 1 K a r te 2 O F F O F F O F F O F F 2 K a r te 3 O F F O F F O F F O F F 3 K a r te 4 O F F O F F O F F O F F 4 K a r te 5 O F F O F F O F F O F F 5 K a r te 6 O F F O F F O F F O F F 6 K a r te 7 O F F O F F O F F O F F 7 K a r te 8 O F F O F F O F F O F F 8 K a r te 9 O F F O F F O F F O F F 9 K a r t e 1 0 O F F O F F O F F O F F A K a r t e 1 1 O F F O F F O F F O F F B K a r t e 1 2 O F F O F F O F F O F F C K a r t e 1 3 O F F O F F O F F O F F D K a r t e 1 4 O F F O F F O F F O F F E K a r t e 1 5 O F F O F F O F F O F F F K a r t e 1 6 O F F O N O F F O F F 0 Terminate CAN Use DIL switches under the heat sink (As shown in fig. 2) to terminate CAN bus by switching to on. This is only to be done for devices with 18 zones and more (Needs only to be done for the last card in the system). Abb. 2 6

7 Zone / Controller Board Assignment Zone Board Fuse Zone Board Fuse Zone Board Fuse 1 1 a + b 33 6 e + f i + j 2 1 c + d 34 6 g + h k + l 3 1 e + f 35 6 i + j a + b 4 1 g + h 36 6 k + l c + d 5 1 i + j 37 7 a + b e + f 6 1 k + l 38 7 c + d g + h 7 2 a + b 39 7 e + f i + j 8 2 c + d 40 7 g + h k + l 9 2 e + f 41 7 i + j a + b 10 2 g + h 42 7 k + l c + d 11 2 i + j 43 8 a + b e + f 12 2 k + l 44 8 c + d g + h 13 3 a + b 45 8 e + f i + j 14 3 c + d 46 8 g + h k + l 15 3 e + f 47 8 i + j a + b 16 3 g + h 48 8 k + l c + d 17 3 i + j 49 9 a + b e + f 18 3 k + l 50 9 c + d g + h 19 4 a + b 51 9 e + f i + j 20 4 c + d 52 9 g + h k + l 21 4 e + f 53 9 i + j a + b 22 4 g + h 54 9 k + l c + d 23 4 i + j a + b e + f 24 4 k + l c + d g + h 25 5 a + b e + f i + j 26 5 c + d g + h k + l 27 5 e + f i + j a + b 28 5 g + h k + l c + d 29 5 i + j a + b e + f 30 5 k + l c + d g + h 31 6 a + b e + f i + j 32 6 c + d g + h k + l Soft-Start Ramp Active by: Start-Up, Heating after standby or alarm. Overtemperature Undertemperatur e Start-up temp. Pause Ramp 2 (seconds per 1 C) Setpoint Ramp 1 (seconds per 1 C) 7

8 Connections (acc. to DIN A) Load, 24-pin Zone PIN 1, 13, 25, 37, 49, 61, 73, 85 1 / 13 2, 14, 26, 38, 50, 62, 74, 86 2 / 14 3, 15, 27, 39, 51, 63, 75, 87 3 / 15 4, 16, 28, 40, 52, 64, 76, 88 4 / 16 5, 17, 29, 41, 53, 65, 77, 89 5 / 17 6, 18, 30, 42, 54, 66, 78, 90 6 / 18 7, 19, 31, 43, 55, 67, 79, 91 7 / 19 8, 20, 32, 44, 56, 68, 80, 92 8 / 20 9, 21, 33, 45, 57, 69, 81, 93 9 / 21 10, 22, 34, 46, 58, 70, 82, / 22 11, 23, 35, 47, 59, 71, 83, / 23 12, 24, 36, 48, 60, 72, 84, / 24 Ground connect to housing! Thermocouple, 32-pin Zone PIN 1, 13, 25, 37, 49, 61, 73, / 9-2, 14, 26, 38, 50, 62, 74, / 10-3, 15, 27, 39, 51, 63, 75, / 11-4, 16, 28, 40, 52, 64, 76, / 12-5, 17, 29, 41, 53, 65, 77, / 13-6, 18, 30, 42, 54, 66, 78, / 14-7, 19, 31, 43, 55, 67, 79, / 15-8, 20, 32, 44, 56, 68, 80, / 16-9, 21, 33, 45, 57, 69, 81, / 25-10, 22, 34, 46, 58, 70, 82, / 26-11, 23, 35, 47, 59, 71, 83, / 27-12, 24, 36, 48, 60, 72, 84, / 28 - Ground connect to housing! 8

9 Alarm connector, 12-pin (Mating connector or alarm cable see accessories) Alarm outputs: 1 = overtemperature, 2 = undertemperature M Ö S max. SELV: 33VAC/70VDC, 2A * Stop machinery * Release production Inputs: 1 = Standby, 2 = Boost PIN Colour Function 1 blue Ö - Alarm 1 (Overtemp) 2 pink M - Alarm 1 (Overtemp) 3 grey S - Alarm 1 (Overtemp) 6 red S - Alarm 2 (Undertemp) 7 black M - Alarm 2 (Undertemp) 8 purple Ö - Alarm 2 (Undertemp) Switch contact PIN Colour Function white + brown E1 - Standby green + yellow E2 - Boost Start-Up The PROFESSIONAL hot-runner controllers are designed for connection to a three-phase power supply source (see Specifications ). The unit features a CEE plug for this purpose. The main switch, which completely disconnects the device from the power supply (mains), is located on the rear panel. After performing a careful cable check, connect the mold to the controller. Connect the operating panel. If you use a PC for controller operation, connect the connecting cable to the interface connector. The alarm connector (accessory) allows you to establish a connection to the injection molding machine as well. Connect the power cable, switch on the controller with the main switch. Set the setpoint values. Be sure to switch off all control zones that are not used currently. If you use a touchscreen operating panel or a PC, you additionally need to start the control operation with HEATING ON/OFF. The controller will now heat up the mold in a uniform manner, thereby drying up any moist heating elements. As soon as the setpoints has been reached, the production process can be started on the basis of the factory settings (see also Soft-Start Ramp ). Should malfunction occur during the start-up process, the cause of the trouble is indicated by corresponding error messages. It is possible to exchange the operating panel in process. This causes no interruptions. Just connect your operating panel to the Operating panel connector. 9

10 Touchscreen Operating Panel WLAN antenna MENU SELECTION button SETPOINT button GROUP button CLEAR button SYSTEM Menu button PRINT button FIXED GROUP button Currently unassigned HELP button TOUCH SCREEN (Enter values or commands with a touch of your finger) BOOST ALARM PAGE UP/DOWN SYSTEM OFF button button buttons button HEATING STANBY DIAGRAM UP/DOWN ON/OFF button button buttons button Select Menu: Setpoint: Zones OFF: Group: With the MENU SELECTION buttons or directly via touchscreen; additionally with the SYSTEM MENU (PROG) and DIAGRAM buttons. Can be set directly via the Parameter menu. Select Display from the menu or the Zone table, then use the SET button to set the setpoint value. For groups, see Group. You can deactivate zones individually via the Parameter menu. Select first zone and last zone, then use the GROUP button to create a group. You can add additional zones at your choice. Use the SET button to set the setpoint value, then use CLEAR to return to normal operation. The FIXED GROUP button (F1) allows you to define, designate and mark groups (e.g. for multi-component molds). Start operation: Activate the heating function with the HEATING ON/OFF (I/O) button. Help: Boost: Standby: Alarms: Print: Turn off: The HELP button calls up the help function in the current menu window. Temporary temperature increase, either with BOOST button or via alarm connector. Temperature reduction for all active zones with STANDBY button or via alarm connector. The ALARM button allows you to call up all currently active alarm messages. The PRINT button allows you to print the current screen content. First, terminate operation with the HEATING ON/OFF button. Use the END button to close the operating system, then turn off the device via the main switch. 10

11 Display Menu Function: Setting: Submenus: Tip: Standard view in operating mode. The screen displays all control zones belonging to the controller, with zone name, actual value, setpoint value and % output. In addition, the controller status, the alarm inputs and outputs and all active alarm messages are indicated as well. Use the SET button to enter the setpoint value of your choice, then press CLEAR to return to operating mode. You can also make this setting for a whole group of control zones by selecting the corresponding zones with the GROUP function. The PAGE UP/DOWN buttons enable blockwise change of the 20 zones displayed; for individual steps, use the UP/DOWN buttons. No submenus available. The % output fields give you an overview of the connected heat load (nozzle or distributor). Once the set setpoint value has been reached, this output value should not be higher than 80%. If higher, the heating system is probably underdimensioned. The GROUP and FIXED GROUP functions enable you to designate and mark the two systems when using 2-component molds. The two systems can then be started separately if required. 11

12 Table Menu Function: Setting: Submenus: This screen displays all control zones with zone name, actual value, setpoint value, percentage output, temperature unit, load current, as boost and reduction temperatures. In addition, the controller status, the alarm inputs and outputs and all active alarm messages are indicated as well. Use the SET button to enter the setpoint value of your choice, then press CLEAR to return to operating mode. You can also make this setting for a whole group of control zones by selecting the corresponding zones with the GROUP function. The PAGE UP/DOWN buttons enable blockwise change of the 20 zones displayed; for individual steps, use the UP/DOWN buttons or the navigation bar provided on the right side of the screen. No submenus available. 12

13 Parameter Menu Function: Setting: Submenus: This screen displays the parameter set for a zone. This menu allows you to designate zones and set the corresponding parameters. The zones can be selected in the top left field and can be given a name in the field immediately to the right. The next line displays the controller board (module) on the left and the channel for the board in the next field. The following fields allow you to switch the zone ON and OFF or to switch to manual operation ( % output ). In manual operation, the output power must be additionally set under default settings. IMPORTANT: There is no mold temperature monitoring in manual operation! Danger of destruction of the connected heating system! In the channel field, you can set an alternative sensor for providing the actual value for the zone in the event of sensor breakage. In the default settings block, you can set the setpoint, BOOST and STANDBY values and the output power for manual operation (% output). Besides, the data recording function can be activated / deactivated here. The channel state block provides information on the operating status and the current load current of the respective zone. The current limit field allows you to set the maximum permissible output current. If the set level is exceeded, overcurrent alarm is automatically triggered. No submenus available. Depending on access level, some setting options may not be available! (See also Options Menu) 13

14 Diagram Menu Function: Setting: Submenus: This menu enables you to define 10 different diagrams with 10 different curves each. Recording takes place during operation after pressing the start all button. You can stop the recording process with stop all. You can select the diagrams in the top left corner. The fields to the right enable you to designate, activate and reset the respective diagram. The Recording block allows you to select the recording intervals. The duration of the recording process is automatically determined by the program. You can also choose between continuous and non-continuous recording. The Y-axis block allows you to set the range of values for the recording. By clicking the zone field after selecting the zone of your choice, you can define the type of value to be recorded. Options include: setpoint or actual value, for temperature as well as % output power. Clicking the OK field or operating the DIAGRAM button calls up the View mode. Clicking the field/button again returns you. 14

15 Utilities Menu Function: Setting: This menu is used for displaying photos of any kind, e.g. mold halves or injectionmolded parts, as well as screen printouts for the system file. On the bottom left, you can select between image and printout view. All saved files are shown in the list above this field. The zoom in, zoom out, original size and window size fields enable you to adjust the image as required. Image files can be stored in the program directory under Images, preferably as jpg or bmp files. Submenus: Tip: Clicking the printings / pictures field switches between image view and printout view. Photos of mold halves can easily be marked with the mold cavities (e.g. using WINDOWS Paint). When stored as an image, such marking or lettering can be helpful in identifying zones and setting zone parameters. 15

16 System Menu Function: Setting: Submenus: This menu allows you to manage the mold memory and the system parameters. Besides, the system overview includes the status and the firmware version of the various controller boards. In the molds submenu, all parameter values of a running mold can be managed. The save as, save, load and delete fields can be used to navigate through this submenu. Once all parameters have been set correctly, they can be saved with save as by entering the designation for the part or simply the drawing number. If changes have been made to an existing mold, these are saved via the save field. To start control operations after the system had been switched off, the appropriate program must first be loaded via the load function. The read-only data record default stores the factory-preset parameters. The Systemparameter (System Parameters) submenu allows you to enter global values that are valid for the entire system (e.g. soft-start parameters). system parameters, for entering parameter data for all zones. system overview, indicates status and firmware version for each controller board. molds, Manages mold data with change history (mold memory) Depending on access level, some setting options may not be available! (See also menu options) 16

17 Options Menu Function: Setting: Submenus: There are various access levels that differ in the scope of the setting and viewing options they provide. For Levels 1 and 2, 4-digit numerical passwords are required. Level 1 (user level) is intended for production, Level 2 (master level) for parameter setting. All higher access levels should only be used by system administrators! The access block is used for entering the passwords for Levels 1 and 2. Once the passwords have been saved, access will be possible only after entering the correct passwords! In the compound heating block, the corresponding function can be activated or deactivated If activated, the fastest zone (e.g. nozzles) will wait for the slowest zone (e.g. manifold). The display section allows you to select the basic unit ( C or F) and the interactive language of your choice. Data recording (e.g. for data assurance purposes) can be activated and deactivated in the data backup block. Besides, you can set the monitoring interval here. The info display field gives you a list of zones that have been activated for data recording. Such activation is carried out via the actual / setpoint temperature field of the Parameters menu, either individually or groupwise. The log data are stored in a special directory and can be retrieved from there as an ASCII file. start explorer direct access to the data management area of the operating system. error log provides a list of all alarms that have been triggered, with date and time. system log provides a list of all user actions, with date an time. Depending on access level, some setting options may not be available! 17

18 Diagnostics Menu Function: Setting: Submenus: Checks the wiring of the connected mold and indicates wiring errors. Checks are performed for each mold separately. If the connected heating system reaches the temperature offset within the preset time, the zone is O.K. Progress is indicated for each zone during the check. Should wiring or system problems occur, this is indicated by an error message. The temperature offset field is used for setting the temperature differential by which the temperature must be increased within the preset time interval. This value can be entered in the maximum duration field. The maximum output percentage can be set via the output field. Clicking the start diagnostics field starts the check and clicking stop diagnostics terminates it. Given 96 zones, the diagnostic process can take several hours if the time range is used fully! No submenus available. 18

19 LC Operating Panel Alarm indicators Actual Value Setpoint Value Heating pulse indicator VIEW BLOCK button 1-24, 25-48, etc. OUTPUT POWER button Dialog window SETPOINT button BOOST button Alarm Indicators CANCEL PROGRAMMING/ UP / DOWN PROGRAMMING / MANUAL STANDBY ZONE OFF buttons ENTER button button button button Thermocouple alarm Lights up in case of TC malfunction (open, reversal). The actual value display shows "- - -" or the temperature of the controller by TC reversal. If Automode is active, the display shows alternating " " and " - A - ". Temperature deviation alarm Flashes during the heating-up phase of the soft-start ramp. Lights up continuously if the temperature exceeds or falls below set limits. In case of overtemperature, the power supply is interrupted. Load alarm Lights up if the set maximum current is exceeded or flashes by open load. In case of overload, the power supply is interrupted. 19

20 Setting the Setpoint Value / Switching off Control Zones Button Command Display Display setpoint Upon pressing this button, the setpoints are displayed, or off for the non-active zones. The button indicator lights up. The dialog window shows Z ALL. Select zone The selected zone is indicated in the Dialog window. Z ALL for all zones. Confirm zone Set setpoint, The selected zone number flashes, or all with Z ALL. TEMP is displayed in the Dialog window. Change the setpoint with the UP / DOWN buttons. - switching off zone Keeping the ESC / OFF button pressed for a few seconds and press again, switches off the selected zone. - switching on zone Press the OK / PRG button 2 times will switch on the selected zone. The last setpoint before deactivating this zone will be set again. Confirm setting Stores the changed values. * Cancel without saving: Setpoint display off Cancel Button indicator off. Back to standard run mode. Increased setpoints will be reached with 100% power output! Pressing this button will lead back one programming step without storing the changed value. Function Keys Button indicator lights up upon activation of respective button (On). Output power Boost function active Standby active Pressing this button once indicates the output power in % of the maximum in the setpoint display. Pressing it again shows you the load current (in amperes). The button indicator % or A lights up. Pressing once more returns to the setpoint value. Increases temperature temporarily. (also externally via alarm connector) Decreases temperature permanently. (also externally via alarm connector) * For manual operation, see separate section. 20

21 Manual Mode ATTENTION: In this mode the hotrunner is not controlled and not switched off in case of overtemperature. So overtemperature and damaging is possible! Button Command Display / Result Manual mode Select zone Upon pressing this button the setpoint display of all inactive zones shows off. The button indicator lights up. The selected Zone is displayed in the dialog window. Confirm zone Set power value, The selected zone no. is flashing. The dialog window shows PULS. With the UP / DOWN buttons in percent. - manual mode Off Keeping the ESC / OFF button pressed for a few seconds and press again, switches off the manual mode of the selected zone. - manual mode On Press the OK / PRG button 2 times will switch on the manual mode of the selected zone. The last power value before deactivating will be set again. Confirm setting Stores the selected power value. Exit setting Button indicator off. Back to run mode. The setpoint display of the zones in manual mode will toggle between the selected power value in percent and PLS. * Exit Setting without storing: Cancel Pressing this button will lead back one programming step without storing the changed value. * To reset (deactivate) manual operation, just turn off the device with the main switch! 21

22 Change Parameters Button Command Display for more than 5 sec. Change Parameters The Dialog window shows Z ALL while the zone numbers are shown in the setpoint displays. Select zone Confirm zone Select menu item The selected zone is indicated in the dialog window. Z ALL for all zones. The selected zone no. is flashing, or all zones at Z ALL The Dialog window shows the first menu item. The Dialog window shows the respective menu item. Confirm menu item Change values Store * Currently used parameters are shown in the setpoint Display. Modified parameters are shown in the setpoint display. (see Parameters / Factory Preset) Modified parameters will be stored. Exit setting Dialog display off. Back to standard run mode. * Exit programming without storing: Cancel Pressing this button will lead back one programming step without storing the changed value. 22

23 23

24 Parameters (Factory Preset) Menu Item Name Function Range Standard Factory-preset The following parameters can only be set for all zones O V T E M P Overtemperature Limit value, alarm output C above setpoint 10 C U N T E M P Undertemperature Limit value, alarm output C below setpoint 10 C R M P E N D Ramp end Final temperature ramp C 120 C R M P T 1 Rise, ramp 1 Heating speed, ramp 1 R M P T 2 Rise, ramp 2 Heating speed, ramp seconds for 1 C 2-10 seconds for 1 C 4 seconds 2 seconds R M P P S E Ramp pause Pause between ramps minutes 1 minute A U T O Automode * Automatic control if TC is open (average output power) 1 = On; 0 = Off 0 (Off) T E M P D N Standby Temperature below setpoint C 50 C T C T Y P Thermocouple Type of Thermocouple J or L J U N I T Temperature unit C or F C or F C P R E S E T Preset Set to factory preset values - - F W V E R Actual firmware version Software version controller card V - C O D E Access code Lock function (inactive) S Y N C Compound heating Deactivates softstart synchronisation 1 = On; 0 = Off 1 (On) The following parameters can be set individually for each zone T E M P U P Boost function Temperature above setpoint 5 60 C 20 C U P T I M E Boost time Duration of boost process s 20 seconds C U R R Overload Limit value 1 16 A 16 A T M P M A X Setpoint limitation Max. setpoint value permitted C 450 C * Automode function is available only after failure-free operation for approx. 15 min! PC Operation PC-based operation requires a licensed software available from HUMMEL AG. Following installation of the software according to the instructions supplied with the product, you can operate the controller in the same way as in the touchscreen version. The scope of functions available is also identical with the touchscreen version, but the mouse pointer is now used for navigation. 24

25 Specifications Working conditions: Controller housing: Touchscreen housing: LC panel housing: Power supply: Connected load: Mold connection: Thermocouple: Power output: Control range: Load fuse: Controller boards: Device connectors: Operation only in closed rooms, max. altitude 2000m M.S.L. Relative humidity up to 80% at 30 C (86 F), moisture condensation not permitted, pollution severity level 2, operating temperature C ( F), storage temperature 0 50 C ( F) Metal enclosure powder-coated, with lockable castors Aluminum housing, powder-coated; 15 -SVGA-LCD display with touchscreen Aluminum housing, powder-coated; with membrane keyboard 4-conductor three-phase network, 230/400 VAC +/-10%, Hz, Overvoltage class II, CEE 32 / 63-A connector approx. 44kW with 63A connector 12 zones to each 24-pin load connector and each 32-pin thermocouple connector (HAN-A) Fe-CuNi type J or L Contactless semiconductor output stage, max. 16 A, zero switching C ( F), precision better 1 C (if hot runner permits) 16 A FF (super fast) Plug-in cards for 6 zones each, with load fuses; no tools required for board replacement 1 alarm connector, 12-pin; M23 1 operating panel connector, 10-pin; M16 2 interface connectors, 9-pin; SUB-D 1 interface connector; USB 25

HPS-C-PRO Hotrunner Controllers. Operating Manual. Valid for

HPS-C-PRO Hotrunner Controllers. Operating Manual. Valid for Valid for gültig item für numbers: Artikelnummern: HPS-C-MULTI 69020.312 (12-zone) 6 68051.008 69020.324 (24-zone) 68051.018 69020.336 (36-zone) (Standard-Steuergeräte) 69020.348 (48-zone) 68051.104 69020.360

More information

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual Valid for item nos.: 68030.001 (1-zone) 68030.002 (2-zone) 68030.004 (4-zone) 68030.006 (6-zone) HPS-C-Slot Hotrunner controllers Operating manual 2 Content Safety instructions...3 Introduction...4 Operating

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

Control accuracy process data assessment Sytem protection flexibility ease of use

Control accuracy process data assessment Sytem protection flexibility ease of use Control accuracy process data assessment Sytem protection fleibility ease of use Functions Ma. zones MINI DIALOG MULTI MASTER MASTER SL PROFESSIONAL PROFESSIONAL LC 1 40 36 60 108 96 180 Etendable Sensor

More information

Control accuracy process data assessment Sytem protection flexibility ease of use

Control accuracy process data assessment Sytem protection flexibility ease of use Setting Standards Control accuracy process data assessment Sytem protection fleibility ease of use Device Functions Ma. zones MINI DIALOG MULTI MASTER MASTER SL PROFESSIONAL PROFESSIONAL LC 1 40 36 60

More information

Gavita Master Controller EL1

Gavita Master Controller EL1 Gavita Master Controller EL1 User manual User manual Gavita Master controller EL1 Dear customer, Congratulations on the purchase of your Gavita Master controller EL1. This manual contains all the information

More information

Hot Runner Controllers. Setting Standards

Hot Runner Controllers. Setting Standards Hot Runner Controllers Setting Standards Setting Standards HUMMEL AG We are based in Waldkirch and Denzlingen that s to the north of Freiburg, right in the triangle where the German, French and Swiss borders

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

Mold Control Systems, Inc.

Mold Control Systems, Inc. PH: 407-855-2899 FAX: 407-855-2855 Mold Control Systems, Inc. SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual SITC Quick Reference:... GITC Quick Reference:...

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm 2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Gavita Master Controller EL1F

Gavita Master Controller EL1F Gavita Master Controller EL1F User manual User manual Gavita Master controller EL1F Dear customer, Congratulations on the purchase of your Gavita Master controller EL1F. This manual contains all the information

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

Installation and User Guide

Installation and User Guide Installation and User Guide 458UNI8 8Channel Universal Dimmer Module Introduction The 458/UNI8 is an 8channel universal, digital transistor, dimmer module. Each channel s mode can be selected for either

More information

GCI-5K INSTALLATION AND OPERATOR S MANUAL

GCI-5K INSTALLATION AND OPERATOR S MANUAL GCI-5K INSTALLATION AND OPERATOR S MANUAL Grid-tied inverter for wind Ningbo Ginlong Technologies 1 INTRODUCTION 2 SAFETY GUIDELINES AND WARNINGS 3 INSTALLATION 3.1 Selecting a location for the inverter

More information

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230 USER MANUAL VIBRATION CONTROL Version 2.2 1 IMPORTANT NOTES Electrical danger within the meaning of this documentation or the warning labels on the product itself respectively means that death, serious

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Recorder DMX DR-Pro Rack

Recorder DMX DR-Pro Rack Manual Recorder DMX DR-Pro Rack Inhaltsverzeichnis 1. Safety instructions... 3 1.1. FOR SAFE AND EFFICIENT OPERATION... 3 2. Overview... 5 2.1. Front view... 5 2.2. Rear view... 6 3. Control... 7 3.1.

More information

Temperature & Humidity Datalogger

Temperature & Humidity Datalogger R6030 Temperature & Humidity Datalogger Instruction Manual Table of Contents Introduction... 2 Product Quality... 3 Safety... 3 Features... 3 Included... 3 Specifications... 4 Instrument Description...

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page

More information

Operating instructions Monitor FD-2 DR2005 DR / / 2007

Operating instructions Monitor FD-2 DR2005 DR / / 2007 Operating instructions Monitor FD-2 DR2005 DR2006 UK 1 2 3 4 5 6 7 8 9 10 11 12 7390342 / 01 07 / 2007 CH1CH2 CH3CH4RUNPRGTST KEY 13 14 15 16 17 18 19 20 21 22 23 24 Content 1 Safety instructions...4 2

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

OPT2011. High-performance distance sensor. Operating Instructions

OPT2011. High-performance distance sensor. Operating Instructions OPT2011 High-performance distance sensor Operating Instructions Status: 15/07/2013 2 Table of Contents 1. Use for Intended Purpose 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning

More information

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions SCHOTT FLM 4 Fiber Lighting Modul Operating Instructions Contents 1. Important information 3 2. Scope of Delivery 3 3. Intended use 3 4. Safety information 4 5. Operation 5 5.1. LED Optics Module 5 5.2.

More information

Application program: description and examples

Application program: description and examples F a n C o i l U n i t C o n t r o l l e r F a n C o i l 4 9 5 5 1 Application program: description and examples Woertz AG Electrotechnical accessories, installation systems Hofackerstrasse 47, P.O. Box

More information

Product and Function Description

Product and Function Description Product and Function Description and the LED display. The touchscreen can be used to select from up to 6 languages for the display of texts and messages. The room temperature controller integrated in Contouch

More information

Manual. Dimmer DMD-12-2

Manual. Dimmer DMD-12-2 Manual Dimmer DMD-12-2 Table of contents 1. Safety instructions... 3 1.1. For safe and efficient operation... 3 2. Overview... 5 2.1. Front view... 5 2.2. Rear view... 6 2.3. Termination... 6 3. Operating

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

Installation Instructions

Installation Instructions Dual EIB bus coupler Order no.: 1246 651, 1246 661, 1246 671 rmation The Gira SmartSensor is a product of the Instabus KNX/EIB System and complies with KNX/EIBA directives. The functions of the device

More information

Micro-Ohmmeter Model 6292

Micro-Ohmmeter Model 6292 Micro-Ohmmeter Model 6292 Quick Start Guide ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

Manual. DP-6 S Dimmer Pack

Manual. DP-6 S Dimmer Pack Manual DP-6 S Dimmer Pack Table of contents 1. Safety instructions... 3 1.1. For safe and efficient operation... 3 2. Product overview... 5 2.1. Front view... 5 2.2. Rear view... 6 3. Wiring diagram...

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

OFP401P0189. Color Sensor. Operating Instructions

OFP401P0189. Color Sensor. Operating Instructions OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection

More information

2-Axis Counter BDD 622

2-Axis Counter BDD 622 2-Axis Counter BDD 622 Technical Description, User's Guide english No. 622-221 D/E. Edition 0701; Subject to modification. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany

More information

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions. 55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger

More information

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016 Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6

More information

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15, 17, 19 screen size User Manual 1U LCD Keyboard Drawer KwikDraw - A Series - With KVM options - 15", 17, 19 screen size 1.1 Important Safeguards Please read all of these instructions carefully before you use the device. Save

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing Optical laser distance sensors Dimensioned drawing We reserve the right to make changes DS_ODSL96BMLTOFS12_en_50117984-01.fm en 03-2013/01 50117984-01 18-30 V DC 0.3 10m Measurement range up to 10000mm

More information

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007 Installation instructions Diagnostic electronics for vibration sensors UK VSE00 70406 / 00 07 / 2007 Contents Safety instructions 3 Function and features 4 Mounting 4 Mounting of the sensors 5 Electrical

More information

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016 Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions

More information

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0 RECTIFIER PSR380 (48V VERSION) USER MANUAL Page 2 (20) Notes to this manual ATTENTION! Read this manual very carefully before installing and commissioning the specified module. This manual is a part of

More information

V /06/ Velleman nv

V /06/ Velleman nv DC LAB POWER SUPPLY WITH DUAL LED DISPLAY DC-LABVOEDING - DUBBELE LED-DISPLAY ALIMENTATION DE LABORATOIRE DC À DOUBLE AFFICHEUR LED ALIMENTACIÓN DC PARA LABORATORIO CON DOBLE DISPLAY LED DC-LABORNETZGERÄT

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

Series RMA Hot Runner Controller Setup and Operation Manual

Series RMA Hot Runner Controller Setup and Operation Manual Series RMA Hot Runner Controller Setup and Operation Manual Littlefuse is a registered trademark of Littlefuse, Inc. G is a registered trademark of the DME Corporation. SafeChange is a trademark of Athena

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

Quick Start Installation and User Manual

Quick Start Installation and User Manual 1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10 4070.83/4--10 PumpDrive DPM Installation and Operating Instructions Dual Pump Module (DPM) These installation and operating instructions are not valid on their own. They must always be applied in conjunction

More information

Thermoelectric Cooler Controller TED1000

Thermoelectric Cooler Controller TED1000 Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

Gavita Master Controller EL2

Gavita Master Controller EL2 Gavita Master Controller EL2 User manual User manual Gavita Master controller EL2 Dear customer, Congratulations on the purchase of your Gavita Master controller EL2. This manual contains all the information

More information

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A User s Guide Table of contents 1 Safety 2 1.1. Installation and startup 2 1.2. General safety instructions 2 Hazardous

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

HI-POT TESTER User Manual

HI-POT TESTER User Manual HI-POT TESTER 7600 User Manual Contents 1. Safety...- 3-1.1 General...- 3 - AC Power Supply...- 4-1.2 Adjustment, Maintenance and Repair...- 5-1.3 Static Electricity...- 5-2. General:...- 6-2.1Packing

More information

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D Specification Number: 23 09 33 Product Name: FRENIC-Eco AC Drives for Variable Torque Fan & Pump Applications (1-125Hp at 208/230V and 1-900Hp at 460V) PART 1: GENERAL 1.01 SUMMARY A. This specification

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

EPS Stromversorgung PSE U. Operating Guide. DC High Efficiency Power Supply

EPS Stromversorgung PSE U. Operating Guide. DC High Efficiency Power Supply EPS Stromversorgung Operating Guide PSE 9000 3U DC High Efficiency Power Supply Attention! This document is only valid for devices with firmware KE: 2.01 and HMI: 2.06 or higher. For availability of updates

More information

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV Driver LC 50W 350 1050mA 54V 0-10V lp EXC UNV EXCITE series SELV Product description Constant current LED Driver Dimmable via 0... 10 V interface Dimming range 1 100 % Adjustable output current between

More information

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

DATA LOGGER (Version V1.3)

DATA LOGGER (Version V1.3) WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Operating instructions DATA LOGGER (Version

More information

SeriBox. antrax Datentechnik GmbH

SeriBox. antrax Datentechnik GmbH info@antrax.de SeriBox - Interface box with serial or USB interface - PC connection / Read IN and OUT signal information - 3 x INput (TTL level / floating contact) - 3 x OUTput (relay contact) Manual Firmware

More information

Table of contents 2 / 19

Table of contents 2 / 19 User manual ADT-48 Table of contents 1. Safety instructions... 3 1.1. FOR SAFE AND EFFICIENT OPERATION... 3 2. Introduction... 4 3. Key Features... 4 4. Control Panel and Functions... 5 5. Connector Configuration...

More information

Series RMT Hot Runner Controller Setup and Operation Manual

Series RMT Hot Runner Controller Setup and Operation Manual Series RMT Hot Runner Controller Setup and Operation Manual Littlefuse is a registered trademark of Littlefuse, Inc. G is a registered trademark of the DME Corporation. SafeChange is a trademark of Athena

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 17W 250 700mA flexc SR EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter

More information

Sollatek SVS Range Voltage Stabilisers User Manual

Sollatek SVS Range Voltage Stabilisers User Manual CONTENTS Subject Page(s) Sollatek SVS Range Voltage Stabilisers User Manual SAFETY Safety 2 Main SVS Features 3 SVS Specification 4-5 Unpacking 6 Inspection 6 Installation 6-9 Operation 10-11 Troubleshooting

More information

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

Dimmer DPX terminal

Dimmer DPX terminal Manual Dimmer DPX-620-3 terminal Table of contents 1. Safety instructions... 3 1.1. FOR SAFE AND EFFICIENT OPERATION... 3 2. Overview... 5 2.1. Front view... 5 2.2. Rear view... 6 2.3. Wiring Diagram...

More information

LED Driver Linear / area dimming

LED Driver Linear / area dimming Driver LC 75W 100 400mA 1-10V lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via 1... 10 V interface Dimming range 10 100 % (Depending on load. For details refer

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 ) Installation Manual 65 (64.56 ) Model: HILF65101 65 Interactive LED/LCD QUICK SETUP GUIDE For further information, see the user manual. Please contact directly if you have questions on the use of the touch

More information

User Manual ELR Electronic DC Load with Energy Recovery

User Manual ELR Electronic DC Load with Energy Recovery User Manual ELR 9000 Electronic DC Load with Energy Recovery Attention! This document is only valid for devices with firmware KE: 2.14 (standard version) resp. KE:2.03 (GPIB,3W) and HMI: 2.07 and DR: 1.6.4

More information

LED Driver Linear / area dimming

LED Driver Linear / area dimming Driver LC 75W 900 1800mA 54V 0-10V lp EXC UNV EXCITE series SELV (US applications) Product description Constant current LED Driver Dimmable via 0... 10 V interface Dimming range 1 100 % Adjustable output

More information

Operation Manual Defender Car vision 5018FullHD Car DVR

Operation Manual Defender Car vision 5018FullHD Car DVR Operation Manual Defender Car vision 5018FullHD Car DVR 1 Thank you for buying Defender Car Vision 5018FullHD car DVR. Before using the device, read attentively this manual and keep it for the whole period

More information

LED Commander 16/2 DMX controller. user manual

LED Commander 16/2 DMX controller. user manual LED Commander 16/2 DMX controller user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Strasse 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

IRC 1100 Kalibrierstrahler / Calibration Source

IRC 1100 Kalibrierstrahler / Calibration Source IRC 1100 Kalibrierstrahler / Calibration Source Betriebsanleitung User Manual IMPAC - Spezialist für berührungslose Temperaturmessung IMPAC - Specialist in non-contact thermometry Content 1 General...10

More information

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual D610H, D610H MKII, D610S, D610T dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

D-Pack 6 Classic ORDERCODE 50315

D-Pack 6 Classic ORDERCODE 50315 D-Pack 6 Classic ORDERCODE 50315 Congratulations! You have bought a great, innovative product from Showtec. The Showtec D-Pack 6 Classic brings excitement to any venue. Whether you want simple plug-&-play

More information

- Ovens - Food processing - Dryers, etc.

- Ovens - Food processing - Dryers, etc. Built-In Temperature Controllers Single channel temperature controllers for use in: - Hot runner applications - Machines for plastics processing - Packaging machines - Ovens - Food processing - Dryers,

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC MultiTherm Shaker Operations Manual Item: H5000-H and H5000-HC Foreword Thank you for purchasing a MultiTherm Shaker. This operations manual contains instructions for the care of this Instrument. In order

More information

7 Digital Photo Frame

7 Digital Photo Frame 7 Digital Photo Frame Instruction manual L7DPF17 12 month manufacturer's warranty -------------------------------------------------------------------------- --------------------------------------------------------------------------

More information

Technical data. Your advantages

Technical data. Your advantages Technical data Nominal torque: 10.000 Nm to 25.000 Nm, bidirectional Customer-specific calibration upon request Rotational speed: 8.000 rpm Accuracy: ±0,5 % Temperature range: -30 C to +85 C Protection

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

User and installation manual

User and installation manual aquacomputer POWERADJUST 3 User and installation manual poweradjust 3 USB Firmware version 1006 aquasuite version 2016 Current as of October 2016 All information contained in this manual is subject to

More information

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0 EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0 16 15 17 2 1. Introduction USER MANUAL To all residents of the European Union Important environmental information about this product This symbol on the

More information