MFC-DN Devicenet Fieldbus expansion Unit AFC3000E-FB-DN-1
|
|
- June Matthews
- 5 years ago
- Views:
Transcription
1 MFC-DN Devicenet Fieldbus expansion Unit AFC3000E-FB-DN-1
2 Revision History Devicenet Fieldbus Expansion Unit Revision Date Manual No. Contents of Revision 08/20/2014 AFC3000E-FB-DN-1 First Release 01/19/2018 AFC3000E-FB-DN-1 Minor revision - Message Output formats fixed (pg.13-24) Manual Numbering Convention AFC3000E-FB-DN-1 DSP1500 = = Servo Servo Press Press AFC1500 AFC3000 = = Nutrunner FUSION = DC DC Hand Hand Tool Tool E = English Version S = Spanish Version *Japanese Version furnished by DDK uses DDK numbering convention. Version Number (Major Revision Level) CC = CC-Link DN = DeviceNet PB = Profibus PN = ProfiNet EN = Ethernet-I/P HW = Hardware Operation Manual SW = Software Manual FB = Fieldbus Manual Any questions regarding the contents of this document or any related matter should be directed to FEC Automation Systems at (586) , faxed to (586) or ed to support@fec-usa.com. The information set forth in the following document is the property of FEC Automation Systems. This document shall not be released to or copied for any person and/or organization without the expressed prior consent of FEC Automation Systems. Unauthorized reproduction or distribution of this manual is strictly prohibited. Please contact FEC Automation Systems if you require additional copies. PAGE 2
3 Forward Devicenet Fieldbus Expansion Unit This manual is intended as a supplement to the AFC3000 Hardware Operation Manual and should be used in conjunction with information provided in that manual. FEC recommends reading that manual before the contents of this manual (which only applies to systems requiring the optional Ethernet I/P interface). Devicenet Interface The AFC3000 Devicenet interface conforms to the open field network known as Devicenet. Control of tools and transactions of message information are executed by Devicenet explicit message communication. Due to conformance with the open field network Devicenet System, connections with Devicenet devices (master/slave) of other manufacturers are enabled. Also, remote I/O communication and message communication can be executed at the same time. System Structure (Devicenet) PLC (Devicenet Master Station) Remote I/O Communication Message Communication Devicenet Slave Station MASTER (1st Spindle) Devicenet Slave Stations of Other Manufacturers 2nd Axis 3rd Axis 32nd Spindle SLAVE AFC3000 Devicenet System PAGE 3
4 Description of the Hardware (Devicenet) Module Status LED DeviceNet Connector Network Status LED PAGE 4
5 EDS File An EDS file is an information file related to the communication specifications of Devicenet compatible devices and a separate, individual file exists for each device. The EDS file is necessary for using the Devicenet PLC configuration software to connect the MFC-EN and the PLC. The EDS file is included in the installation CD for the AFC3000 User Console or may be downloaded from the FEC website. Please refer to the instruction manual for the Devicenet configuration software concerning the appropriate method for using the EDS file. Module Pin Configuration No. Signal Wire Color Description 1 V- Black Power cable - side 2 CAL L Blue Communication data Low side 3 SHIELD - Cable Shield 4 CAL H White Communication data High 5 V+ Red Power cable + side Manufacturer: Phoenix Contact Type: Connector plug Model: MSTB 2.5/5-ST-5.08 AU M Applicable wire size: AWG 14 to 23 or 0.25mm 2 to 2.5mm 2 * The connector is included with the equipment. (To be wired by customer) * The cable is not included with the equipment. Please prepare a LAN cable of Category 5e or higher on your own equipment. Please prepare these on your own. Caution Be sure to connect the cable with all power turned OFF. PAGE 5
6 List of LED Indications The module LEDs indicate the states of the nodes of the AFC3000 DeviceNet interface and the network state. A : Network Status LED B : Module Status LED A B LED Color State Details Network Status LED Module Status LED OFF Off Offline Offline or power is not supplied. Green Red Red/ Green Lit up Online Communicating normally. Flash Connection established not Although online, connection is not established. Lit up Error A critical error has occurred. Flash Connection timeout A connection timeout has occurred once or more. Lit up Repeated Test mode OFF Off Power OFF Power is not supplied. Green Red Red/ Green Lit up Online Normal state Flash Connection established not Due to incomplete configuration or connection failure, the device must be re-recognized. Lit up Error A critical error has occurred. Flash Error A recoverable error has occurred. Lit up Repeated Test mode PAGE 6
7 I/O Signal Specifications (Devicenet) Devicenet Fieldbus Expansion Unit Maximum Setting Standard Setting MASTER Spindle PLC I/O Input/Output PLC MASTER Spindle MASTER Spindle PLC Message Input/Output PLC MASTER Spindle 32bytes (256 points) 12bytes (96 points) 2048 word (4096 bytes) 16 word (32bytes) 32bytes (256 points) 8bytes (64 points) 2048 word (4096 bytes) 16 word (32bytes) AFC3000 Devicenet System Signal Specifications (PLC MASTER Spindle) Number of MASTER Spindle Input Points 4 words 8 bytes (256 points) FEC Input signals (PLC Outputs) are factory set and cannot be changed. Word No. BIT Signal Word No. BIT Signal 0 STOP 0 SEQ SELECT No.17 1 RESET 1 SEQ SELECT No.18 2 REVERSE 2 SEQ SELECT No.19 3 START 3 SEQ SELECT No.20 4 SEQ SELECT BIT 0 4 SEQ SELECT No.21 5 SEQ SELECT BIT 1 5 SEQ SELECT No.22 6 SEQ SELECT BIT 2 6 SEQ SELECT No.23 No.01 7 SEQ SELECT BIT 3 7 SEQ SELECT No.24 8 SEQ SELECT BIT 4 No.03 8 SEQ SELECT No.25 9 CYCLE COUNT UP 9 SEQ SELECT No CYCLE COUNT CLEAR 10 SEQ SELECT No SEQ SELECT No. ENABLE 11 SEQ SELECT No INPORT 1 12 SEQ SELECT No INPORT 2 13 SEQ SELECT No INPORT 3 14 SEQ SELECT No INPORT 4 15 SEQ SELECT No.32 0 SEQ SELECT No.1 0 BYPASS SPDL No.1 1 SEQ SELECT No.2 1 BYPASS SPDL No.2 2 SEQ SELECT No.3 2 BYPASS SPDL No.3 3 SEQ SELECT No.4 3 BYPASS SPDL No.4 4 SEQ SELECT No.5 4 BYPASS SPDL No.5 5 SEQ SELECT No.6 5 BYPASS SPDL No.6 6 SEQ SELECT No.7 6 BYPASS SPDL No.7 No.02 7 SEQ SELECT No.8 7 BYPASS SPDL No.8 No.04 8 SEQ SELECT No.9 8 BYPASS SPDL No.9 9 SEQ SELECT No.10 9 BYPASS SPDL No SEQ SELECT No ID DATA CLEAR 11 SEQ SELECT No ID SELECT ENABLE 12 SEQ SELECT No SEQ SELECT No SEQ SELECT No SEQ SELECT No PAGE 7
8 Word No. BIT Signal Word No. BIT Signal 0 BYPASS SPDL No.11 0 BYPASS SPDL No.27 1 BYPASS SPDL No.12 1 BYPASS SPDL No.28 2 BYPASS SPDL No.13 2 BYPASS SPDL No.29 3 BYPASS SPDL No.14 3 BYPASS SPDL No.30 4 BYPASS SPDL No.15 4 BYPASS SPDL No.31 5 BYPASS SPDL No.16 5 BYPASS SPDL No.32 6 BYPASS SPDL No.17 6 No.05 7 BYPASS SPDL No BYPASS SPDL No.19 No BYPASS SPDL No BYPASS SPDL No BYPASS SPDL No BYPASS SPDL No BYPASS SPDL No BYPASS SPDL No BYPASS SPDL No * The word No. at the PLC side differs according to the setting of the node address, etc., so please be sure to confirm before using. Please refer to the AFC3000 Operation Manual, Section and for description of the respective signals. Caution The allocation of the input signals is fixed (cannot be changed). The unused area of the inputs is also secured (and cannot be used by other devices). Cautio n Be careful of the following points when using the BYPASS No. # (1 to 32) signals. If a certain Unit is to be put in the BYPASS mode, set the corresponding signal among the BYPASS No. # (1 to 32) signals to ON with the START signal of the Unit being in the OFF state and the BUSY signal of the MASTER Spindle for PC communication and I/O (PLC) control being in the OFF state. When fastening is executed with any of the spindle BYPASS No. # (1 to 32) signals in the ON state, the fastening judgment of that Unit will be ignored as if it does not exist. Also, when any of the BYPASS No. # (1 to 32) signals is set to ON with the BUSY of the MASTER Spindle being in the ON state, the sequence judgment may result in REJECT. PAGE 8
9 AFC3000 Devicenet System Signal Specifications (MASTER Spindle PLC) Number of MASTER Spindle Output Points 32 bytes (256 bits) The table below is an example of the Output mapping using Ethernet I/P. Output bits (256) are allowed to be user-programmed using the AFC3000 User Console Software. The allocation of the signals can be set on any bit/pin through the PLC Output Layout setting function of the AFC3000 Software. Please refer to PLC Output Layout of the <<AFC3000 Operation Manual>> for list of available output signals (Master and individual spindle signals) EXAMPLE ONLY: Actual signal placement may vary upon user configuration Word No. BIT Signal Word No. BIT Signal 0 TOTAL REJECT 0 SEQ No.17 SELECTED 1 TOTAL ACCEPT 1 SEQ No.18 SELECTED 2 TOTAL ABNORMAL 2 SEQ No.19 SELECTED 3 TOTAL READY 3 SEQ No.20 SELECTED Output word 4 TOTAL BUSY 4 SEQ No.21 SELECTED Output word No. 1 5 END 5 SEQ No.22 SELECTED No. 3 6 SEQ SELECT BIT 0 6 SEQ No.23 SELECTED Output 7 SEQ SELECT BIT 1 7 SEQ No.24 SELECTED Output Signal 8 SEQ SELECT BIT 2 Signal 8 SEQ No.25 SELECTED Setting 9 SEQ SELECT BIT 3 Setting 9 SEQ No.26 SELECTED Example 10 SEQ SELECT BIT 4 Example 10 SEQ No.27 SELECTED 11 SPINDLE IN BYPASS 11 SEQ No.28 SELECTED 12 DATA AVAILABLE 12 SEQ No.29 SELECTED 13 CURRENT WARNING 13 SEQ No.30 SELECTED 14 CAL WARNING 14 SEQ No.31 SELECTED 15 ZERO LEVEL WARNING 15 SEQ No.32 SELECTED 0 SEQ No.1 SELECTED 0 REJECT No.1 1 SEQ No.2 SELECTED 1 ACCEPT No.1 2 SEQ No.3 SELECTED 2 ABNORMAL No.1 3 SEQ No.4 SELECTED 3 BYPASS No.1 4 SEQ No.5 SELECTED 4 REJECT No.2 Output word Output word 5 SEQ No.6 SELECTED 5 ACCEPT No.2 No. 2 No. 4 6 SEQ No.7 SELECTED 6 ABNORMAL No.2 Output 7 SEQ No.8 SELECTED 7 BYPASS No.2 Output Signal 8 SEQ No.9 SELECTED Signal 8 REJECT No.3 Setting 9 SEQ No.10 SELECTED Setting 9 ACCEPT No.3 Example 10 SEQ No.11 SELECTED 10 ABNORMAL No.3 Example 11 SEQ No.12 SELECTED 11 BYPASS No3 12 SEQ No.13 SELECTED 12 REJECT No.4 13 SEQ No.14 SELECTED 13 ACCEPT No.4 14 SEQ No.15 SELECTED 14 ABNORMAL No.4 15 SEQ No.16 SELECTED 15 BYPASS No.4 PAGE 9
10 Word No. BIT Signal Word No. BIT Signal 0 REJECT No.5 0 RUN REV HI REJ No.5 1 ACCEPT No.5 1 RUN REV LO REJ No.5 2 ABNORMAL No.5 2 LO CUR LIMIT WARNING No.5 3 READY No.5 3 HI CUR LIMIT WARNING No.5 Output word 4 BUSY No.5 4 CURRENT WARNING No.5 Output word No. 5 5 BYPASS No.5 5 CAL VOLTAGE WARNING No.5 6 TORQUE HOLD No.5 No. 7 6 ZERO VOLT WARNING No.5 Output 7 PAR SEL (BIT0) No.5 7 JUDGE COMBO (BIT1) No.5 Output Signal 8 PAR SEL (BIT1) No.5 Signal 8 JUDGE COMBO (BIT2) No.5 Setting 9 PAR SEL (BIT2) No.5 Setting 9 JUDGE COMBO (BIT3) No.5 Example 10 PAR SEL (BIT3) No.5 Example 10 JUDGE COMBO (BIT4) No.5 11 PAR SEL (BIT4) No.5 11 JUDGE COMBO (BIT5) No.5 12 TORQUE HI REJ No.5 12 JUDGE COMBO (BIT6) No.5 13 TORQUE LO REJ No.5 13 JUDGE COMBO (BIT7) No.5 14 FTQ HI REJ No.5 14 JUDGE COMBO (BIT8) No.5 15 FTQ LO REJ No SNUG TQ HI REJ No TQ INHIBIT HI REJ No F ANGLE HI REJ No F ANGLE LO REJ No.5 3 Output word 4 DIFF + ANG REJ No.5 4 Output word 5 DIFF ANG REJ No.5 No. 8 5 No. 6 Thru 6 RATE 1 HI REJ No.5 6 No. 16 Output 7 RATE 1 LO REJ No.5 7 Signal 8 RATE 2 HI REJ No.5 Output 8 Setting 9 RATE 2 LO REJ No.5 Signal 9 Example 10 RATE 3 HI REJ No.5 Setting RATE 3 LO REJ No.5 Example ST TIME HI REJ No ST TIME LO REJ No ND TIME HI REJ No ND TIME LO REJ No.5 15 The example above (output word 5-7) shows an example of all available signals for each spindle. While normally not all signals are used, any of the signals (for each spindle) can be preset (programmed using the AFC3000 software) to any output bit. * The word No. at the PLC input side differs according to the setting of the node address, etc., so please be sure to confirm before using. Please refer to the AFC3000 Operation Manual, Section and for description of the respective signals. Caution The unused area of Word 01 to 16 is also secured. PAGE 10
11 Fieldbus Setting (Devicenet) Devicenet Fieldbus Expansion Unit The fieldbus settings are set in the Fieldbus Setting menu of the AFC3000 User Console. The following setting window is displayed when Multi Fieldbus Setting is selected at the menu bar. In the Bus Type Select/communication window, selection of the fieldbus type, uploading, downloading, and verification of fieldbus settings with respect to the Unit, and browsing and saving of fieldbus settings with respect to the PC can be performed. Caution - The standard set values are set as the factory settings in the Unit. Do not change the settings unless there is a special reason. - Be sure to perform backup before changing the fieldbus settings of the Unit. Bus Type Select: The type of bus is selected from the list. Also, when Upload is executed, the bus type is judged automatically and reflected in the selection part. Configuration File Browse: A fieldbus configuration file (*.nrfcf) is read from the PC. Save: A fieldbus configuration file (*.nrfcf) is saved in the PC. Upload: Download: Verify: The fieldbus settings are read from the MASTER Spindle for PC communication and I/O (PLC) control. The fieldbus settings are written into the MASTER Spindle for PC communication and I/O (PLC) control. (Re-activate the control power after writing.) The fieldbus settings of the MASTER Spindle for PC communication and I/O (PLC) control and the fieldbus settings in the User Console are compared. PAGE 11
12 In the Devicenet screen (of the AFC3000 Software), setting of the Devicenet interface is performed. The network settings, the I/O size, and the message size can be changed. Default (the settings are set to the factory settings when this is selected) Node Address: 0 I/O Setting Data Length [PLC to MASTER Spindle: 8 bytes [64 bits I/O Setting Data Length [MASTER Spindle to PLC: 32 bytes [256 bits Message Data Length [PLC to MASTER Spindle: 32 bytes Message Data Length [MASTER Spindle to PLC: 4096 bytes * The number of message block bytes is fixed at 250 bytes. Communication Speed Setting range: 156kbps, 250kbps, 500kbps Node Address Setting range: 0 to 63 I/O setting Data Length [PLC to MASTER Spindle Setting range: 2 bytes [16 bits to 12 bytes [96 bits Data Length [MASTER Spindle to PLC Setting range: 2 bytes [16 bits to 32 bytes [256 bits The Number of Message Bytes Settings Data Length [PLC to MASTER Spindle Setting range: 0 byte [0 bit to 32 bytes Data Length [MASTER Spindle to PLC Setting range: 0 byte [0 bit to 4096 bytes Note: Power must be cycled if any of this configuration is changed and downloaded to the Master controller PAGE 12
13 Fieldbus Message Setting (MASTER Spindle PLC) The message information output from the MASTER Spindle for PC communication and I/O (PLC) control is set in the AFC3000 User Console software. The maximum size of the message output that can be handled is 4096 bytes. The output order of the message data is: Multi Format Data Spindle format data of Spdl. No. 1 Spindle format data of Spdl. No. 2 Spindle format data of Spdl. No. 32. The message output format is selectable (in the AFC3000 Software) to output either BCD format or ASCII format, both examples are listed below. Please contact the PLC manufacturer regarding the setting at the PLC side. Multi Format Output Items (BCD Format) Output Items Number of Bytes Date 4 Fastening Data 2013/5/ 28 Multi Format LSB (1word) PLC Input Data MSB (16word) Time 4 12:34: ID *1 32 ABCDEF A B C D E F NUL NUL SEQ No (1 to 32) SEQ Judgment *2 2 REJECT ACCEPT ABNORMAL STOP RESET STOP BYPASS START OFF IN CYCLE SEQ Cycle Count *1: The ID is fixed at 32 bytes (16 words) and is output in ASCII format. NULL letters are set as unset values. *2: Please refer to AFC3000 Operation Manual, Sequence Judgment regarding the details of SEQ Judgment. Do not use the following characters when inputting the ID data. : backslash (yen mark), / : slash, Caution : : colon, * : asterisk,? : question mark, : double quotation, < > : inequality signs, : pipe sign - PAGE 13
14 Multi Format Output Items (ASCII Format) Output Items Number of Bytes Fastening Data Multi Format PLC Input Data Letter String Date /5/ / 0 5 / 2 8 Time 8 12:34: : 3 4 : 5 6 ID*1 32 ABCDEF A B C D E F NUL NUL NUL NUL NUL SEQ No. (1 to 32) REJECT R E J ACCEPT A C C SEQ Judgment *2, *3 4 ABNORMAL A B N STOP S T O P RESET STOP R S T BYPASS B Y P SEQ Cycle Count START OFF S O F F IN CYCLE I N C Y *1: The number of output bytes of the ID is fixed at 32 bytes (16 words). NULL letters are set as unset values. *2: Please refer to AFC3000 Operation Manual, Sequence Judgment regarding the details of SEQ Judgment. *3: (20H) is the ASCII code for (space). Do not use the following characters when inputting the ID data. : backslash (yen mark), / : slash, : : colon, * : asterisk,? : question mark, Caution : double quotation, < > : inequality signs, : pipe sign PAGE 14
15 Spindle Format Output Items (BCD Format) Output Items Number of Bytes Fastening Data LSB (1word) Spindle format MSB (2 word) Spindle No. (1 to 32) PAR No. (1 to 32) Spindle Judgment* Spindle Cycle Count (8 digits) TOOL Cycle Count (8 digits) Peak Torque* Final Torque* Snug Torque* st Peak Torque* nd Peak Torque* Final Angle* Differential Angle* Rate 1* Rate 1 Increment Torque* Rate 1 Increment Angle* Rate 2* Rate 2 Increment Torque* Rate 2 Increment Angle* Rate 3* Rate 3 Increment Torque* Rate 3 Increment Angle* st Time* nd Time* Cycle Time* Peak Current* Angle at Peak Torque* Rundown Revolutions* ZERO Voltage* CAL Voltage* Spindle Cycle Count (4 digits)* TOOL Cycle Count (4 digits)* Load rate *1: In regard to the Spindle Judgment, Judgment Data 1 is output as 1, Judgment Data 2 is output as 2, Error Data is output as 3, and 1st Reject Item is output as 4. The values output as 1, 2, and 3 are respectively set by bit allocation from Fieldbus Message Setting of the AFC3000 User Console. Note: shaded area described on next page PAGE 15
16 *2: With each of the output items (besides Spindle No., Parameter No., Spindle Judgment, Spindle Cycle Count (8 digits 4 digits), Tool Cycle Count (8 digits 4 digits), and Load rate ), the results are output in the order of: indication up to a maximum of 6 digits (without the decimal point) in 2 words (4 bytes), sign, and number of digits to the right of the decimal point Sign 2 Number of Digits to the right of the Decimal Point Indication Details Indication Details 0 + value 0 No digits right of decimal point 1 - value 1 1 digit right of the decimal point 2 2 digits right of the decimal point 3 3 digits right of the decimal point 4 4 digits right of the decimal point 5 5 digits right of the decimal point *3: With each of Spindle Cycle Count (4 digits) and Tool Cycle Count (4 digits), numerical values of the millions, hundred thousands, ten thousands, and thousands places are output as 4-digit BCD data. Once the cycle count reaches 9,999,999 (99 99BCD), the next number (10,000,000) is output as (00 00BCD). PAGE 16
17 Spindle Format Output Items (ASCII Format) Output Items Number of Bytes Fastening Data Spindle format 1 word 2 word 3 word 4 word 5 word Spindle No. (1 to 32)*1 2 1 PAR No. (1 to 32) 2 2 Spindle Judgment* Spindle Cycle Count (8 digits) TOOL Cycle Count ( digits) Peak Torque* Judgment Occurrence Final Torque* Judgment Occurrence Snug Torque* Judgment Occurrence 1st Peak Torque nd Peak Torque Final Angle* Judgment Occurrence Differential Angle* Judgment Occurrence Rate 1* Judgment Occurrence Rate 1 Increment Torque Rate 1 Increment Angle Rate 2* Judgment Occurrence Rate 2 Increment Torque Rate 2 Increment Angle Rate 3* Judgment Occurrence Rate 3 Increment Torque Rate 3 Increment Angle st Time* Judgment Occurrence 2nd Time* Judgment Occurrence Cycle Time* Peak Current* Warning Angle at Peak Torque Rundown Revolutions* Judgment Occurrence ZERO Voltage CAL Voltage Spindle Cycle Count (4 digits)* TOOL Cycle Count ( digits)* Load rate *1: (20H) is the space code (space). *2: In regard to the Spindle Judgment, Judgment Data 1 is output as 1, Judgment Data 2 is output as 2, Error Data is output as 3, and 1st Reject Item is output as 4. The values output as 1, 2, and 3 are respectively set by bit allocation from Fieldbus Message Setting of the AFC3000 User Console. PAGE 17
18 *3: With each of the output items for which there are set values of high and low limits, the results are output in the order of: sign, result indication (including the decimal point), judgment code, and 1st Reject (failure) item. Also with items besides the differential angle and rates 1 to 3, 1 is not output, and for the peak current, 3 is not output. 1Sign L X Judgment Code Indication Details Indication Details Space (20H) + value Space (20H) Within high and low limit, no warning (peak current) - (2DH) - value H (48H) Outside high limit, high limit warning (peak current) L (4CH) Outside low limit, low limit warning (peak current) 31st Reject Item Indication X (58H) Space (20H) Details 1st Reject item Reject item besides the 1st Reject *4: With each of Spindle Cycle Count (4 digits) and Tool Cycle Count (4 digits), numerical values of the millions, hundred thousands, ten thousands, and thousands places are output as 4-digit BCD data. Once the cycle count reaches 9,999,999 (99 99BCD), the next number (10,000,000) is output as (00 00BCD). PAGE 18
19 Judgment Data 1 and 2 Items (in common with BCD and ASCII) The Judgment data and the Abnormal data of the operation results are set by bit allocation. In regard to the setting method, please refer to Fieldbus Message Setting in the <<AFC3000 User Console Instruction Manual>>. Classification Item Details Logic - Message information to be output by a combination of OR and AND is set. Spindle Judgment Fastening Reject Items Auxiliary Information Signal REJECT ACCEPT ABNORMAL BYPASS STOP RESET STOP START OFF Torque Reject Angle Reject Rate Reject Time Reject Rundown Revolutions Current Value Warnings Judgment Combination Bits 1 to 8 This is output when a fastening result falls outside a judgment range. This is output when fastening ends with the fastening results being within the judgment ranges. This is output when an error occurs in the system or during the fastening operation. This is output when the BYPASS signal is set to ON at the start of fastening or during the fastening process. This is output when the STOP signal is set to OFF at the start of fastening or during the fastening process. This is output when the RESET signal is set to ON at the start of fastening or during the fastening process. This is output when the START signal is set to OFF during the fastening operation with Deadman being set as the start method in the sequence setup. Peak torque low limit Reject/peak torque high limit Reject Final torque low limit Reject/final torque high limit Reject Snug torque high limit Reject Start torque inhibit high limit Reject Final angle low limit Reject/final angle high limit Reject Differential - angle Reject/Differential + angle Reject Rate 1 low limit Reject/Rate 1 high limit Reject Rate 2 low limit Reject/Rate 2 high limit Reject Rate 3 low limit Reject/Rate 3 high limit Reject 1st time low limit Reject/1st time high limit Reject 2nd time low limit Reject/2nd time high limit Reject Rundown revolution high limit Reject/rundown revolution low limit Reject Low current value limit warning/high current value limit warning Allows the configuration of multiple REJECT items to be combined onto single outputs (8 combination outputs available). The configuration of these signals is set using the AFC3000 Software (Fieldbus Message Setup Screen). Abnormal Data Items (in common with BCD and ASCII) Abnormal State No. Abnormal State 1 Abnormal State 3 Abnormal State 4 Abnormal State 5 Abnormal State 6 Abnormal State 8 Abnormal State 9 Abnormal State 10 Torque transducer error Preamplifier error System memory error Servo apply error Servo type error Servo amplifier error Setting data error Multi signal error Details PAGE 19
20 1st Reject (Failure) Item (in common with BCD and ASCII) Identifies the reason or cause for a fastening that is stopped / interrupted BEFORE reaching the target torque (or angle) due to a Reject (outside of the programmed limits). (Some programmed limits can cause the fastening process to stop due to a Reject prior to fastening completion) Example: A cycle run with a missing fastener will cause a 1 ST Time High Limit Reject. A fastener that reached the Final Angle High Limit setting before reaching Standard Torque will cause a Final Angle High Limit reject. Note: If the fastening reaches the end of the fastening cycle and rejects, no data will be reported in this data item. The BCD output format data is shown below for each type of reject item. Item Output Format (BCD Format) No REJECT 00 Peak torque high limit REJECT 01 Final torque high limit REJECT 03 Final angle high limit REJECT 05 Rate 1 high limit REJECT 09 Rate 1 low limit REJECT 10 Rate 2 high limit REJECT 11 Rate 2 low limit REJECT 12 Rate 3 high limit REJECT 13 Rate 3 low limit REJECT 14 1st time high limit REJECT 15 2nd time high limit REJECT 17 Rundown revolution high limit REJECT 19 Snug torque high limit REJECT 21 Start torque inhibit high limit REJECT 22 PAGE 20
21 Fastening Judgment Data Output Items: Example of Spindle Judgment Output Data 1 & 2 (common with BCD and ASCII format) The spindle fastening judgment (from a performed fastening cycle) is set by bit allocation of these 2 data bytes. These judgment status bits are set at the end of a completed fastening cycle. Note: Actual Bit configuration is set using the AFC3000 software in the Fieldbus Message Setup screen Actual bit placement may differ than what is shown. Judgment data setting (example from AFC3000 software) Judgment Data 2 (BIT) Judgment Data 1 (BIT) Item Logic OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR OR ACCEPT REJECT ABNORMAL BYPASS STOP RESET STOP Peak Torque High Limit REJECT Peak Torque Low Limit REJECT Final Torque High Limit REJECT Final Torque Low Limit REJECT Final Angle High Limit REJECT Final Angle Low Limit REJECT Error (Abnormal) Data Setting The error data (Abnormal reason) of Spindle judgment is set by bit allocation of 1 byte. The data corresponds to the abnormal state No. when an abnormal condition occurs. Item Error (Abnormal) Data BIT Abnormal state 1 (Torque Transducer) Abnormal state 3 (Preamplifier) Abnormal state 4 (System Memory) Abnormal state 5 (Servo Amp Reply) Abnormal state 6 (Servo Type) Abnormal state 8 (Servo Amp) Abnormal state 9 (Parameter) Abnormal state 10 (Multi Signal) PAGE 21
22 Example 1: Spindle judgment is ACCEPT (Using setup of Judgment data from previous page) Output Item Spindle Judgment 1 Judgment Data 1 1word 2word 2 Judgment Data 2 3 Error Data 4 Occurring Fastening Reject Example 2: Spindle judgment is REJECT : Final Torque Low Limit Reject Output Item Spindle Judgment 1 Judgment Data 1 1word 2word 2 Judgment Data 2 3 Error Data 4 Occurring Fastening Reject Example 3: Spindle judgment is ABN3-3 Output Item Spindle Judgment 1 Judgment Data 1 1word 2word 2 Judgment Data 2 3 Error Data 4 Occurring Fastening Reject Example 4: Spindle judgment is REJECT : Peak Torque Low Limit Reject Output Item Spindle Judgment 1 Judgment Data 1 1word 2 Judgment Data 2 3 Abnormal Data 2word 4 1st Reject Item Also, if the fieldbus message is unset, the following contents are output. Data Format Output Item Number of Bytes Spindle cycle count (4 digits) 2bytes BCD Format Tool cycle count (4 digits) 2bytes For each of the cycle counts, numerical values of the millions, hundred thousands, ten thousands, and thousands places are output as 4-digit BCD data. Once the cycle count reaches 9,999,999 (99 99BCD), the next number (10,000,000) is output as (00 00BCD). Fieldbus Message Output Example (when not set) (Note:PLC output ref. for Allen Bradley) Spindle No. 1 2 Format Output Item Result Output PLC Output Spindle cycle count 1234 C Tool cycle count C Spindle cycle count C Tool cycle count C Spindle cycle count C Tool cycle count C PAGE 22
23 Message Information Output Example (Multi Format) (Note:PLC output ref. for Allen Bradley) Sequence Cycle Count Multi Format Output Item Result Output PLC Input (BCD Format) PLC Input (ASCII Format) 216 C C00 to C C07 Date C C08 to C C17 Time 10:23:36 C C18 to C C25 C26 to Sequence Judgment REJECT C C :23:36 REJ_ Sequence No. 1 C C30 to C31 _1 Final Message Information Area (when 250 bytes are set) * (20H) is the space code (space). C124 C124 PAGE 23
24 Message Information Output Example (Spindle Format) (Note:PLC output ref. for Allen Bradley) Spdl. No. 1 Output Item Result Output Peak Torque [N m Final Torque [N m Final Angle [deg Rate 1 [N m/deg Rate 2 [N m/deg Rate 3 [N m/deg st Time [sec nd Time [sec Peak Torque [N m Spindle Format PLC Input (BCD Format) PLC Input (ASCII Format) C C00 to C C07 _12.34 C C08 to C C15 _12.34 C C16 to C C23 _123.4HX C C24 to C C C C34 to C C C C44 to C C C C54 to C C63 _ C C64 to C C C C Peak Torque [N m C C Peak Torque [N m C C Free area C74 C74 Final Message Information Area (when max 4096 bytes setup) * (20H) is the space code (space). C4095 C4095 PAGE 24
25 Fieldbus Message Setting (PLC MASTER Spindle) 1. Contents of Sent Data: ASCII Data Refer to 3. below regarding the actual sent results. 2. Max. message length: 16words/32 bytes (As configured in AFC3000 Software) 3. Input Example Select ASCII letters to send message information from the PLC to the MASTER Spindle for PC communication and I/O (PLC) control. The message information sent from the PLC to the MASTER Spindle for PC communication and I/O (PLC) control is reflected in the fieldbus communication, the AFC3000 User Console, the Unit RS232C, and the expansion RS232C. - The standard set value for the ID input data is 32 bytes (16 words). Be careful because even when a value beyond this is set, only the 32 bytes from the start are saved in the fastening result retention of the Unit. - Do not use the following characters. Caution : backslash (yen mark), / : slash, : : colon, * : asterisk,? : question mark, : double quotation, < > : inequality signs, : pipe sign PLC configuration PAGE 25
26 PLC Setting Example This procedure is written for using Rockwell Automation RXLogix5000 V and Allen Bradley CompactLogix L32E. If the system is not the same as listed above, setup may be different. Please contact to PLC manufacturer for detail as each PLC may be different 1. Register MASTER Spindle Fieldbus unit to RSNetworks for Devicenet From the TOOLS menu, select EDS Wizard Follow the screen for adding EDS file to RSNetWorks for DeviceNet. The EDS file can be downloaded from our web 2. Once the EDS file is imported to RSNetWorks, the MASTER Devicenet unit will appear as below: HMS Fieldbus System AB (Hassbjer Micro Sys) Communication Adapter Anybus CompactCom DeviceNet. PAGE 26
27 Drag the icon to the DeviceNet connection field. The module will be located on the graphic side of the display. Right-Click the module added and select Properties. In the General page, edit name and address for system. AFC3000 PAGE 27
28 3. Go back to the scanner module properties. Using the Scanlist tab, select the device to be edited, open the I/O parameters. Make sure the input size and output size are same as set-up in the Multi Unit Fieldbus set-up performed earlier. 12 After the parameter is configured for DeviceNet, download the setup to the PLC. (The configuration will be stored in the DeviceNet Master memory) PAGE 28
29 The I/O signals for DeviceNet will be available at Local memory where the DeviceNet Master is located. For the message communication, Read Tag and Data buffesr needs to be added to tag table. PAGE 29
30 4. Transferring the fastening result data using the MSG function. For setting up the MESSAGE function, first the AFC3000 needs to be configured for the data type that needs to be sent to the PLC. Configuration is done in the AFC3000 Userconsole Software. Select Field Bus Message Setup from Multi pull down menu. Select the DATA TYPE format (BCD or ASCII). Data from the Master (Multi) and Spindle (Axis) must be configured in the table below each tab. The Multi format contains the Header data (such as Date, Time, Sequence #, Cycle Count, etc. aka data that comes from the Master Unit) The Axis format contains the actual spindle fastening data (such as Torque, Angle, Time, Rate, etc.) Right click on the table and select the item from the pop up window that you wish to be transferred. PAGE 30
31 (Example of Multi format selection shown above) Note: Selecting Null deletes the item from the list. PAGE 31
32 (Example of Axis format selection shown below this format will be for EACH spindle connected in the system to the Master Unit) When the system has more than 1 spindle, the data will be output in spindle sequential order as shown below. Data from total fastening status (Multi data) Data from SPINDLE 1 Data from SPINDLE 2 Data from SPINDLE 3 Data from up to SPINDLE 32 After the fastening result data has been setup, download the changed configuration to the Master controller. PAGE 32
33 PLC program. Devicenet Fieldbus Expansion Unit 1. Read_Tag needs be added to the Controller Tags for message transfer This data tag contains the configuration of the message transfer. Each MSG command needs to have its own Read_ tag. The MSG command is used for transferring the fastening result. PAGE 33
34 Property of the MSG command is shown below. (Right Click in MSG command) A2 5 DEVICENET_MESS Message Type CIP Generic Service Type Get Attribute Single Service Code E Class A2 Instance 1 17 Attribute 5 Destination The controller tag added for Devicenet should be selected Note: Each message command can only handle 250 bytes. If more than 250 bytes of data needs to be transferred, another controller tag needs be added (Read_tag) for the buffer and another MSG command needs be added. The second MSG command should have its instance as 2 with its Destination address incremented to the next block of data (250, 500, 750, 1000, etc.) and so on up to a maximum of 17 for up to 4096 bytes of message data). Example: [AFC3000:C.Data(250) for the second block of 250 bytes PAGE 34
35 At the communication tab screen, select Path. DeviceNet Master module should be selected. Add 2,3 after that. 2 denotes the communication command for message data 3 describes for AFC1500 DeviceNet Node Address. PAGE 35
36 An example of a message transfer PLC program is shown below. DEVICENET Message 1 ST set DEVICENET Data 2 ND Set DEVICENET Data 1 ST set DEVICENET Data 2 ND Set DEVICENET_MESSAGE[0 DEVICENET_MESSAGE[ This program transfers up to 250 bytes of fastening result data. The first MSG command has 1 as Instance and is sending the data into DEVICENET_MESSAGE[0 memory block. The second MSG command has 2 as Instance and sending the data into another data memory block DEVICENET_MESSAGE[250 that would have been manually added when the second Read_tag was added. Note: All instructions above that show AFC1500 would be AFC3000 for the AFC3000 setup. Note: The above information contained in this procedure are meant for REFERENCE ONLY when configuring an FEC Ethernet I/P interface using FEC AFC3000 User Console Software, FEC AFC3000 Nutrunner System, Rockwell Automation RSlogix 5000 software and Allen Bradley CompactLogix L32E hardware. Actual application configuration may differ from this set-up depending on the PLC chosen for the application. PAGE 36
MFC-EN Ethernet-I/P Fieldbus expansion Unit AFC3000E-FB-EN-2
MFC-EN Ethernet-I/P Fieldbus expansion Unit AFC3000E-FB-EN-2 Revision History Ethernet-I/P Fieldbus Expansion Unit Revision Date Manual No. Contents of Revision 08/20/2014 AFC3000-FB-EN-1 First Release
More informationFC 300 DeviceNet and Allen Bradley Control logix 5550
Introduction... 2 FC 300 DeviceNet card... 2 Creation of an EDS file... 4 Configuring the FC 300 with RS Networx... 7 I/O communication with RS Logix 5000... 1 0 Explicit messages with RS Logix 5000...
More informationCVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual
1/36 CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual N - Copyright 2011, St Herblain France All rights reserved. Any unauthorized use or copying of the contents or part thereof is
More informationtools with torque tubes small assembly cell mobile assembly carts HFC 3000 II SERIES
applications Hand Held Nutrunner TOOL Series tools with torque tubes small assembly cell mobile assembly carts Flexible telescoping torque tubes provide balanced, compact structures to absorb reaction
More informationPluto Gateway Rockwell PLC Integration Manual (RSNetWorx for DeviceNet)
Pluto Gateway Rockwell PLC Integration Manual (RSNetWorx for DeviceNet) English v2b 2TLC172012M0202_B Revision history: Version Date Change 1A 2008-10-08 First release. 2A 2010-11-29 Changed to ABB style
More informationVLT 5000 DeviceNet and Allen Bradley Control logix 5550
Foreword... 2 VLT 5000 DeviceNet card... 2 Configuring the VLT 5000 with RS Networx... 4 I/O communication with RS Logix 5000... 6 Explicit messages with RS Logix 5000... 8 1 Foreword This application
More informationBridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB
BridgeWay PROFIBUS to DeviceNet Gateway User Manual Part No. AB7605 Pyramid Solutions 1850 Research Drive, Suite 300 Troy, Michigan 48083 Phone 248-524-3890 Web www.pyramid-solutions.com Publication PUB-AB7605-005
More informationenforce DSP1500 Main Unit Hardware Manual SECOND Edition October 2008
enforce DSP1500 Main Unit Hardware Manual SECOND Edition October 2008 Automation Systems 51327 Quadrate Drive Phone: (586) 781-2100 Macomb, MI. 48042 Fax: (586) 781-0044 Web: www.fec-usa.com E-mail: support@fec-usa.com
More informationX-gateway Interface Addendum DeviceNet Scanner Interface
X-gateway Interface Addendum DeviceNet Scanner Interface Rev. 1.10 HMS Industrial Networks AB Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 ge-sales@hms-networks.com
More information1.5 axis motion controller
Ver. CHARGE POWER CN3 CN CN SERVOPACK RUN RD MCW5 STS SD 6 +4V SGDH- Ver. CHARGE CN CN3 CN SERVOPACK POWER 0 MCW5 RUN STS RD SD 6 +4V R88A-MCW5-@.5 axis motion controller Advanced motion made perfectly
More informationOPERATION INSTRUCTION MANUAL
MICRO E-HS-2.1 ELECTRIC SERVO MICRO NUTRUNNER OPERATION INSTRUCTION MANUAL FEC MICRO NR 2nd Edition Rev.1 December 2012 WARNING All applicable national and local codes must be followed when installing
More informationAnybus CompactCom 40 Diagnostic Events for EtherNet/IP
Anybus CompactCom 40 Diagnostic Events for EtherNet/IP SCM-1202 037 1.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial
More informationDriver Manual (Supplement to the FieldServer Instruction Manual) FS X30 DeviceNet Master Adapter Driver
A Sierra Monitor Company Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-114 X30 DeviceNet Master Adapter Driver APPLICABILITY & EFFECTIVITY Effective for all systems manufactured
More informationTable of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO
DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2
More informationAPPLICATION NOTE: Reading/writing data from Anybus-S EtherNet/IP using ControlLogix5000 MSG instruction. HMS Industrial Networks
APPLICATION NOTE: Reading/writing data from Anybus-S EtherNet/IP using ControlLogix5000 MSG instruction HMS Industrial Networks Revision Notes Date: Revision: Notes: Responsible 2003-08-22 0.10 Document
More information^2 Accessory 55E DeviceNet Option
1^ USER MANUAL ^2 Accessory 55E DeviceNet Option ^3 Universal Field Bus Adapter Network (UNET) ^4 3A0-603485-DUxx ^5 October 23, 2003 Single Source Machine Control Power // Flexibility // Ease of Use 21314
More informationAPPLICATION NOTE. Reading/writing data from an X-gateway EtherNet/IP using ControlLogix5000 MSG instruction SCM HMS Industrial Networks
APPLICATION NOTE Reading/writing data from an X-gateway EtherNet/IP using ControlLogix5000 MSG instruction SCM-1202-097 HMS Industrial Networks Revision Notes Date: Revision: Notes: Responsible 2003-08-22
More informationDN120 DeviceNet Gateway User Manual
DN120 DeviceNet Gateway User Manual DN120 PN 84-210010 Rev A Table of Contents CHAPTER 1 OVERVIEW... 4 CHAPTER 2 INSTALLATION... 5 MOUNTING... 5 WIRING... 6 DeviceNet Interface... 6 Serial Channel Interface...
More informationCDN067-3 Quick Start Guide
CDN067-3 Quick Start Guide For use with RSNetworx MKS Instruments, Inc. Control & Information Technology Product Group 1321 Rutherford Lane Suite 200 Austin, TX 78753 Main: 512.719.8000 Fax: 512.719.8096
More informationL5351 DeviceNet Communications Interface
L5351 DeviceNet Communications Interface Technical Manual HG353798 Issue 2 Copyright SSD Drives, Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
More informationFieldServer FS DeviceNet Slave Adapter Driver
FieldServer FS-8700-22 DeviceNet Slave Adapter Driver Driver Manual (Supplement to the FieldServer Instruction Manual) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after December
More informationPreface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1
Preface Thank you for purchasing the Pro-face LogiTouch Type-D DeviceNet master unit. The LogiTouch Type-D (also referred to as the LT Type-D ) allows connection to the DeviceNet Fieldbus to access many
More informationConfigure an X-Gateway EtherNet/IP Adapter with RSLogix 5000
Configure an X-Gateway EtherNet/IP Adapter with RSLogix 5000 HMS Industrial Networks AB Page 1 (17) More info about the network and products For the latest manuals, EDS-files, etc., see www.anybus.com
More information2002 Series DeviceNet Technical Manual
2002 Series DeviceNet Technical Manual Table of Contents 2002 Series DeviceNet Technical Manual 2002 Introduction...4 Product Overview...4 About DeviceNet...5 Overview...5 2002 DeviceNet Features...5 Cabling
More informationCVI Controllers - Profinet IO - Manual
07/20 1/18 CVI Controllers - Profinet IO - Manual Copyright 20, St Herblain France All rights reserved. Any unauthorized use or copying of the contents or part thereof is prohibited. This applies in particular
More informationUSER S MANUAL. FX2N-64DNET DeviceNet Interface Block
USER S MANUAL FX2N-64DNET DeviceNet Interface Block FX2N-64DNET DeviceNet Interface Block Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation
More information12.3 Fieldbus I/O Board
12.3 Fieldbus I/O Board 12.3.1 Overview of Fieldbus I/O The Fieldbus I/O option is an option to add fieldbus slave function (DeviceNet, PROFIBUS-DP, CC-Link, EtherNet/IP) to the robot Controller. A fieldbus
More informationSMARTLINX INTERFACE MODULE
SMARTLINX INTERFACE MODULE FOR DEVICE NET Instruction Manual PL-583 April 2001 R 33455830 Rev. 1.1 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others,
More informationUsing an AIMCO Gen 4 Controller on a Rockwell PLC with Profibus
Using an AIMCO Gen 4 Controller on a Rockwell PLC with Profibus Authors: Kade Olson and Sam Stewart Date: June 15, 2015 Introduction Many AIMCO torque controllers come standard with Profibus. A common
More informationTritex II EtherNet/IP - Option
Tritex II EtherNet/IP - Option Tritex II Ethernet/IP Option.doc 10/15/13 REV B 952-368-3434 Tritex II EtherNet/IP Option.doc 2 10/15/13 Contents 1. General... 5 1.1. IP Address... 6 1.2. Network Classes...
More informationFieldServer FS DeviceNet Master Adapter Driver
FieldServer FS-8700-114 DeviceNet Master Adapter Driver Driver Manual (Supplement to the FieldServer Instruction Manual) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after March 2017.
More information1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.
Getting Started This is a brief document designed to quickly get you started setting up your 2002 Series valve manifold with integrated Numatics G2-1\2 Profibus-DP communication protocol. Please note that
More informationDeviceNet Drive Profile CFW-09
Motors Automation Energy Transmission & Distribution Coatings DeviceNet Drive Profile CFW09 Communication Manual DeviceNet Drive Profile Communication Manual Serie: CFW09 Language: English Software Version:
More information# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or
EQ7000 User Manual Rev 1.04 www.equustek.com Revision 1.04 Feb 20th, 2017 #286-5489 Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: 888-387-3787 or 604-266-8547 www.equustek.com Page 1 Contents INTRODUCTION...4
More informationBook of Implementation Guidelines AVI/VMS DeviceNet Reader Installation & Configuration for PLC-5
Advance Manufacturing Engineering Book of Implementation Guidelines AVI/VMS DeviceNet Reader Installation & Configuration for PLC-5 AMS 0220 Section 14.2.4 Revision Date: 08/01/07 Page 1 of 44 Revision:
More informationFESTO K.K. IO-Link Connection Guide (EtherCAT(R) Host Communications) Machine Automation Controller NJ-series
Machine Automation Controller NJ-series IO-Link Connection Guide (EtherCAT(R) Host Communications) FESTO K.K. Proportional pressure regulator valve (VPPM series) [IO-Link Master Unit] OMRON Corporation
More informationG3 Series DeviceNet TM Technical Manual
G3 Series DeviceNet TM Technical Manual Table of Contents G3 Series DeviceNet Technical Manual PAGE About DeviceNet... 3 Overview... 3 G3 DeviceNet Features... 3 Cabling and Drop Line Lengths (as defined
More informationDEFAULT IP ADDRESS
REAL TIME AUTOMATION 2825 N. Mayfair Rd. Suite 111 Wauwatosa, WI 53222 (414) 453-5100 www.rtaautomation.com EtherNet/IP - DeviceNet Master Gateway MODBUS TCP - DeviceNet Master Gateway Copyright 2007 Real
More informationMPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice
MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths
More informationDriver Manual. FS DeviceNet Master Adapter Driver
A Sierra Monitor Company Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-114 DeviceNet Master Adapter Driver APPLICABILITY & EFFECTIVITY Effective for all systems manufactured
More informationMotor controllers CMMS-ST, for stepper motors
Key features Performance characteristics Compactness Motion control Small dimensions Full integration of all components for controller and power section, including RS232 and CANopen interface Integrated
More informationABSOLUTE ROTARY ENCODER WITH DEVICENET INTERFACE USER MANUAL
ABSOLUTE ROTARY ENCODER WITH DEVICENET INTERFACE USER MANUAL 1. Introduction... 4 1.1 Control and Information Protocol (CIP)... 5 1.2 Object modell... 6 2. Data Transmission... 7 2.1. The Object Dictionary...
More informationCONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS
CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS This configuration guide provides programming information for the DL-PC (ISA) and DL-STD (STD 80 and 32) Remote I/O Link applications.
More informationSMARTLINX INTERFACE MODULE
SMARTLINX INTERFACE MODULE FOR DEVICE NET Instruction Manual December 2001 R Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product
More informationG3 Series PROFIBUS DP Technical Manual
G3 Series PROFIBUS DP Technical Manual Table of Contents G3 Series PROFIBUS DP Technical Manual PAGE About PROFIBUS-DP...3 Overview...3 G3 PROFIBUS-DP Features...3 Cabling and Drop Line Lengths (as defined
More informationD0 DEVNETS and Allen Bradley Set up. RSNetworx
D0 DEVNETS and Allen Bradley Set up RSNetworx G 2 Setup D0 DEVNETS with Allen Bradley RSNetWorx For those who are using the D0 DEVNETS as a slave with an Allen Bradley PLC, the examples on the following
More informationP2 Configuration Guide
P2 Configuration Guide March 2018 Rev. 4.00 #220, 550 71 st Avenue SE Calgary, Alberta, Canada T2H 0S6 Phone: (403) 255-9544 Fax: (403) 259-2343 www.barnettprotalk.com E-mail: sales@barnettprotalk.com
More information1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.
Getting Started This is a brief document designed to quickly get you started setting up your 200/2012 Series valve manifold with integrated Numatics G2-2 Profibus-DP communication protocol. Please note
More informationMCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.
Installation OPERATING INSTRUCTIONS Order Code: 175G9002 Adjustment 35 mm (1.38 inches) Control power and mains supply must be removed from the MCD 200 before attachment or removal of an accessory module.
More informationABB Drives. User s Manual DeviceNet Adapter Module RDNA-01
ABB Drives User s Manual DeviceNet Adapter Module RDNA-01 DeviceNet Adapter Module RDNA-01 User s Manual 3AFE64504223 REV C EN EFFECTIVE: 16.11.2006 2006 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationAnybus-CC CFW-11. User s Manual. Phone: Fax: Web: -
Anybus-CC CFW-11 User s Manual Anybus-CC User s Manual Series: CFW-11 Language: English Document Number: 0899.5750 / 06 Publication Date: 09/2013 CONTENTS CONTENTS... 3 ABOUT THE MANUAL... 6 ABBREVIATIONS
More informationCJ Series EtherNet/IP TM Connection Guide. SMC Corporation Solenoid Valve (SI Unit EX600-SEN#) P657-E1-01
CJ Series EtherNet/IP TM Connection Guide SMC Corporation Solenoid Valve (SI Unit EX600-SEN#) P657-E1-01 About Intellectual Property Rights and Trademarks Microsoft product screen shots reprinted with
More informationR7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)
INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, points (DeviceNet) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined
More informationGRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912B-70. Instruction Manual EN
GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912B-70 Instruction Manual EN294-1796 II Introduction Thanks you very much for your purchasing the Graphic Digital Indicator with PROFIBUS interface
More informationApplication Note: 105U/905U-G-ET1 EtherNet IP & CompactLogix PLC
Y ELPRO Technologies Pty Ltd Application Note: 105U/905U-G-ET1 EtherNet IP & CompactLogix PLC PURPOSE The purpose of this document is to provide the reader with an application note for using an Allen Bradley
More informationOPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FDNA-01 DeviceNet adapter module User s manual
OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FDNA-01 DeviceNet adapter module User s manual List of related manuals See section Related manuals on page 15. You can find manuals and other product documents
More informationTECHNICAL NOTE TNOI36
TECHNICAL NOTE TNOI36 Title: DeviceNet TM Slave Communication Product(s): G3, Modular Controller Enhanced Master and DSP ABSTRACT The purpose of this document is to describe the G3 s support for DeviceNet
More informationSECTION 5 HSLRT6 WINDOWS BASED SETUP PROGRAM REFERENCE
The Windows based set-up program is menu driven, allowing the user to easily view data, alter setup variables or set machine timing (machine offset, timing signal locations, etc.), using a PC running the
More informationColor-Sensing Connected Components Building Block. Quick Start
Color-Sensing Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
More informationG5 Weighing Instrument
G5 Weighing Instrument Program version 1.4.X Fieldbus Option Manual PM and RM types CONTENTS 1. Introduction... 1-1 General... 1-1 Module installation... 1-2 Ordering information... 1-3 2. Modules...
More informationBECKHOFF. Application Notes.
BECKHOFF Application Notes www.beckhoffautomation.com Configuring Beckhoff Products for an AB 1747- SDN DeviceNet Scanner with an SLC-500 PLC and RSNetWorx BK-AppNote-009 1.0 3 October 2007 For additional
More informationCJ-series DeviceNet Connection Guide OMRON Corporation 3G3RX-V1 Series Inverter
CJ-series DeviceNet Connection Guide OMRON Corporation 3G3RX-V1 Series Inverter P547-E1-01 About Intellectual Property Rights and Trademarks Microsoft product screen shots reprinted with permission from
More informationABSOLUTE ROTARY ENCODER WITH DEVICE NET INTERFACE USER MANUAL
ABSOLUTE ROTARY ENCODER WITH DEVICE NET INTERFACE FRABA Inc. 1800 East State Street, Suite 148, Hamilton, NJ 08609 Phone +1 609 750 8705, Fax. +1 609 750 8703 www.posital.com, info@posital.com Imprint
More informationAllen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon
Allen-Bradley PLC-5 Backup Communication Module User Manual (1785-BCM, 1785-BEM) product icon Important User Information Because of the variety of uses for this product and because of the differences between
More informationConnection Guide HMS Industrial Networks
Machine Automation Controller NJ-series EtherCAT(R) Connection Guide HMS Industrial Networks Anybus Communicator P560-E1-02 About Intellectual Property Rights and Trademarks Microsoft product screen shots
More informationVarispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1
YASKAWA Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1 YASKAWA MANUAL NO. SIBP C730600 01B Copyright 2004 YASKAWA ELECTRIC CORPORATION All rights reserved.
More informationConnecting Compax3 I22T11 and Allen Bradley / Rockwell PLCs via DeviceNet
CONTROL TECHNOLOGY FROM PARKER IEC61131-3 C3 I22T11 Ethernet HEDA Connecting Compax3 I22T11 and Allen Bradley / Rockwell PLCs via DeviceNet C3I22_A1010_eng Warranty Disclaimer While efforts were made to
More informationDanfoss FCD 300 AS-i and Siemens DP/AS-i Link 20E
Introduction This application note describes how to set up an ASi system between a Danfoss FCD 300 frequency converter and Profibus DP/AS-i Link 20E gateway from Siemens. DP/AS-i Link 20E is a gateway
More informationPLC2 Board Communication Manual CANopen Slave
PLC2 Board Communication Manual CANopen Slave 02/2006 Series: PLC2 0899.5809 E/3 Contents Contents List of Tables 4 List of Figures 4 About the Manual 5 Abbreviations and Definitions...............................
More informationCommunication settings: Network configuration can be done via the Anybus IP configuration setup tool or via the on board Web server
SmartLinx EtherNet/IP instruction and use APPLICATION GUIDE Objective: Show the user how to configure and use an EtherNet/IP SmartLinx communication module. AG082415 While every effort was made to verify
More informationIntegration of In-Sight with AB PLCs running RSLogix
Integration of In-Sight with AB PLCs running RSLogix Author: Samantha Frost Published: August 11, 2017 Revision: 1.0 Contents Communicate with a Rockwell ControlLogix PLC... 4 Integration with RSLogix
More informationVersion 2.0. January For Firmware versions 4.25 and 5.2
Version 2.0 January 2016 For Firmware versions 4.25 and 5.2 ConveyLinx module firmware and functionality is protected by U.S. and international patents. For complete patent information visit www.pulseroller.com/patents
More informationAnybus -S CANopen. Fieldbus Appendix. ABS-COP-3 Rev HMS Industrial Networks AB. Germany Japan Sweden U.S.A UK
Fieldbus Appendix Anybus -S CANopen ABS-COP-3 Rev. 2.02 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 + 44 (0) 1908-359301
More information)(&,Q Chapter 1: Outline
Chapter 1: Outline User Console Version A3.53 Chapter 1: Outline Page 1-1 Chapter 1: Outline User Console Version A3.53 1.1 Functions Outline w General The AFC1200 ISA Fastening System is a culmination
More informationPROFIBUS Interface WM : PD
ふ PROFIBUS Interface WM : PD4000303 This is a hazard alert mark. This mark informs you about the operation of the product. Note This manual is subject to change without notice at any time to improve the
More informationDeviceNet for SERVOSTAR S300/S600/S700
DeviceNet for SERVOSTAR S300/S600/S700 and DeviceNet HMS Simulator Paul Coughlin DeviceNet DeviceNet is an 8-Byte Field Bus System for medium range industrial I/O control Originally created in 1996 for
More informationDeviceNet Communications
DeviceNet Communications For PanelView Plus and PanelPlus CE Terminals 2711P User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More informationTeaching Color-Sensing Connected Components Building Block. Quick Start
Teaching Color-Sensing Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.
More informationMPCR Series DeviceNet Technical Manual
MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction...3 Product Overview...3 About DeviceNet...4 Overview...4 MPCR DeviceNet Features...4 Cabling and Drop Line Lengths (as
More informationGRAPHIC DIGITAL INDICATOR
GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912-70 Instruction Manual Minebea Co., Ltd. Measuring Components Business Unit EN294-1425 Forwards Thanks you very much for your purchasing MINEBEA
More informationHow to configure an Anybus Modbus-TCP slave module with Unity Pro L
How to configure an Anybus Modbus-TCP slave module with Unity Pro L HMS Industrial Networks AB Page 1 (25) Document history Revision Date Description Author 1.00 2007-06-20 Created Thorbjörn Palm 1.01
More informationServo Nutrunners Multi-type / Single-type AFC-1500SERIES
Servo Nutrunners Multi-type / Single-type AFC-1500SERIES1 ADAPTS TO AN OPEN NETWORK THE SMALLEST AND LIGHTEST IN THE INDUSTRY HIGH PERFORMANCE, FULLY DIGITAL NUT RUNNERS AFC-1500 SERIES 1 Cost Flexibility
More informationApplication Note. Using the Yaskawa V1000 AC Drive and SI-N3/V DeviceNet Option Kit with AB CompactLogix Programmable Controller. Applicable Product:
Application Note Using the Yaskawa V1000 AC Drive and SI-N3/V DeviceNet Option Kit with AB CompactLogix Programmable Controller Applicable Product: SI-N3/V DeviceNet Option Kit www.yaskawa.com - 1 - January
More informationInstall the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
More informationHow to configure DeviceNet with Anybus NetTool for DeviceNet.
How to configure DeviceNet with Anybus NetTool for DeviceNet. HMS Industrial Networks AB Page 1 (12) History Revision Date Description Responsible 1.00 2006-09-15 Released Thorbjörn Palm 1.01 2006-11-17
More informationABB Drives. User s Manual DeviceNet Adapter Module RDNA-01
ABB Drives User s Manual DeviceNet Adapter Module RDNA-01 DeviceNet Adapter Module RDNA-01 User s Manual 3AFE64504223 Rev D EN EFFECTIVE: 16.07.2007 2007 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationDeviceNet Network Configuration
User Manual DeviceNet Network Configuration 1756 ControlLogix, 1756 GuardLogix, 1769 CompactLogix, 1769 Compact GuardLogix, 1789 SoftLogix, Studio 5000 Logix Emulate Important User Information Solid-state
More informationFACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES
FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES HOST INTERFACE MODULES With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationDevice manual Encoder with DeviceNet interface RM7 RN /00 08/2014
Device manual Encoder with DeviceNet interface UK RM7 RN7 706373/00 08/2014 Content 1 Preliminary note................................................. 4 1.1 Symbols used...............................................
More informationCJ Series IO-Link Connection Guide (EtherNet/IP TM Host Communications) OMRON Corporation Proximity Sensor (E2E-series IO-Link)
CJ Series IO-Link Connection Guide (EtherNet/IP TM Host Communications) OMRON Corporation Proximity Sensor (E2E-series IO-Link) [IO-Link Master Unit] OMRON Corporation NX-series IO-Link Master Unit (NX-ILM[][][])
More informationDeviceNet Adapter. 20-COMM-D FRN 1.xxx. User Manual
DeviceNet Adapter 20-COMM-D FRN 1.xxx User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines
More informationCPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800
WTI Part No. 12348 Rev. B CPM Series Control Port Manager Models CPM-1600 and CPM-800 User's Guide 5 Sterling Irvine California 92618 (949) 586-9950 Toll Free: 1-800-854-7226 Fax: (949) 583-9514 http://www.wti.com
More informationCJ Series EtherNet/IP TM Connection Guide. OMRON Corporation RFID Reader/Writer (V680S-series) P626-E1-01
CJ Series EtherNet/IP TM Connection Guide OMRON Corporation RFID Reader/Writer (V680S-series) P626-E1-01 About Intellectual Property Rights and Trademarks Microsoft product screen shots reprinted with
More informationThroughout this manual we use notes to make you aware of safety considerations:
Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have
More informationHow to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT
How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE ENGLISH Important User Information Liability Every care has been taken in the preparation of this document.
More informationFieldbus Appendix AnyBus-S FIPIO
Fieldbus Appendix AnyBus-S FIPIO DOC.ID: ABS-FIP-1 Rev. 1.00 HMS Industrial Networks Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-2271 sales-ge@hms-networks.com
More informationDeviceNet Communications for PanelView Terminals
User Guide DeviceNet Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the DeviceNet versions of the PanelView terminals. This
More informationSection 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents
Section 1.0 Description... 2 Section 2.0 Installation 2.1 Soft starter to gateway connection... 3 2.2 Soft starter configuration... 3 2.3 Gateway to DeviceNet connection... 3 2.4 Gateway configuration...
More informationUser Guide AnyBus NetTool for DeviceNet
User Guide AnyBus NetTool for DeviceNet Rev. 1.00 HMS Industrial Networks Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-2271 sales-ge@hms-networks.com
More informationX-SEL Serial Communication Protocol Specification (Format B)
X-SEL Serial Communication Protocol Specification (Format B) [Applicable Models] X-SEL-J/K Main Application V0.99 X-SEL-JX/KX Main Application V0.42 TT Main Application V0.18 X-SEL-P/Q Main Application
More information