Fieldbus Appendix AnyBus-S FIPIO

Size: px
Start display at page:

Download "Fieldbus Appendix AnyBus-S FIPIO"

Transcription

1 Fieldbus Appendix AnyBus-S FIPIO DOC.ID: ABS-FIP-1 Rev HMS Industrial Networks Germany Japan Sweden U.S.A sales-ge@hms-networks.com sales-jp@hms-networks.com sales@hms-networks.com sales-us@hms-networks.com

2

3 Table of Contents Table of Contents Preface Chapter 1 Chapter 2 Chapter 3 About This Manual How To Use This Manual... P-1 Important user information... P-1 Related Documentation... P-1 Revision list... P-1 Conventions used in this manual... P-2 Support... P-2 About the AnyBus-S FIPIO Features Compatible Products Overview Connectors Node Address Switches Indicators Basic Operation Node Address Configuration Baud Rate Identity Customization Status Handling Profiles and Classes Parameter Data Handling Command Data Adjustment Data Configuration Data Mailbox Interface Fault and Status Information Basic Settings Set Node Address (SET_NODE_ADDRESS) Read Switch Setting (READ_SWITCH_SETTING) Set Profile and Class (SET_PROFILE_CLASS) Configuration Data Get Configuration (GET_CONFIGURATION) Accept Configuration (ACCEPT_CONFIGURATION) Adjustment Data Get Adjustment Data (GET_ADJUSTMENT) Accept Adjustment Data (ACCEPT_ADJUSTMENT) Command Data Get Specific Command (GET_SPECIFIC_COMMAND) Accept Specific Command (ACCEPT_SPECIFIC_COMMAND)

4 Table of Contents II Status Handling Set Specific Status (SET_SPECIFIC_STATUS) Set Standard Status (SET_STANDARD_STATUS) Identification Set Identification Info (SET_IDENT_INFO) Communication Set Promptness Time (SET_PROMTNESS_TIME) Set Channel Fault (SET_CHANNEL_FAULT) Chapter 4 Fieldbus Specific Registers Fieldbus Specific Area (0x640-0x7BF) Fieldbus Type (0x7CC - 0x7CDh) Appendix A Connectors Application Connector...A-1 Fieldbus Interface...A-1 Appendix B Mechanical Specification Measurements, PCB...B-1 Measurements, Connectors & Switches...B-2 Standard Configuration...B-2 Appendix C Electrical Characteristics Supply Voltage...C-1 Power Consumption...C-1 Protective Earth...C-1 Appendix D Environmental Specification Temperature... D-1 Relative Humidity... D-1 EMC compliance... D-1

5 Preface About This Manual How To Use This Manual This manual provides an overview of the AnyBus-S FIPIO slave module and is intended to be used in conjunction with the AnyBus-S Design Guide. The reader of this document is expected to have basic knowledge in the FIPIO fieldbus system, and communication systems in general. Important user information The data and illustrations found in this document are not binding. We reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and should not be considered as a commitment by HMS Industrial Networks AB. HMS Industrial Networks AB assumes no responsibility for any errors that may appear in this document. There are many applications of this product. Those responsible for the use of this device must ensure that all the necessary steps have been taken to verify that the application meets all performance and safety requirements including any applicable laws, regulations, codes, and standards. AnyBus is a registered trademark of HMS Industrial Networks AB. All other trademarks are the property of their respective holders. Related Documentation Document name AnyBus-S Parallel Design Guide FIPIO Standard Profiles Reference Manual Author HMS Industrial Networks AB WorldFIP Revision list Revision Date Author Chapter PeP All First release

6 About This Manual P-2 Conventions used in this manual The following conventions are used throughout this manual: Numbered lists provide sequential steps Bulleted lists provide information, not procedural steps The term module is used when referring to the AnyBus module The term application is used when referring to the hardware that is connected to the AnyBus Application Connector Hexadecimal values are written in the format NNNNh, where NNNN is the hexadecimal value. Commands instructs the module to perform certain task Functions are commands that returns data Support HMS Sweden Tel: +46 (0) Fax: +46 (0) Online: HMS America Tel: Fax: Online: HMS Germany Tel: Fax: Online: HMS Japan Tel: Fax: Online:

7 Chapter 1 About the AnyBus-S FIPIO The AnyBus-S FIPIO integrates all the analog and digital functionality required to communicate over a FIPIO based fieldbus network, and can be customised to appear as a vendor specific implementation rather than a generic AnyBus-S module. Features Identity customization Supports all FIPIO profiles and classes Node address configuration using on board switches or via the application interface Supports both FIP and WorldFIP standards Compatible Products This product is a member of the AnyBus concept of interchangeable fieldbus modules. This makes it fully interchangeable with any fieldbus system supported by the AnyBus-S platform. Overview # 1 Application Connector 2 Fieldbus Connector 3 Node address switch x10 4 Node address switch x1 5 Status Indicators 6 AnyBus Watchdog LED

8 About the AnyBus-S FIPIO 1-2 Connectors Application Connector The application connector features a standard AnyBus-S 2kbyte parallel DPRAM interface. For further information, please consult the general AnyBus-S Design Guide. FIPIO Connector The module supports both dsub and board to board connectors on the fieldbus interface. The standard connector is a male 9 pin dsub connector. For more information about connectors and pin assignments, see Appendix A-1 Connectors Node Address Switches These switches can be used to set the node address in the range The switches are read once during startup, i.e. if the setting is changed, the module requires a reset for the change to have effect. Node addresses in the range can be set using the mailbox command SET_NODE_ADDRESS, see 3-2 Set Node Address (SET_NODE_ADDRESS). Example: In the following example, the node address switches form address 71. ( 7 x x 1 = 71 ) x10 x1 Indicators AnyBus Watchdog Consult the general AnyBus-S Design Guide for further information. Status Indicators These leds indicate run time status and errors to the user Led State 1 - Run Led Green Normal operation (Device powered up and operating) Off Device not powered or major failure (no communication) 2 - Err Led Red Major unrecoverable fault Flashing Red Bus not connected or promptness timeout Off Not powered or device operating normally 3 - I/O Led Red External device error Off Device operating normally 4 - COM Led Flashing Yellow Bus activity Off No bus activity All Flashing Module not initialised

9 Chapter 2 Basic Operation Node Address Configuration The node address of the module can be set either via hardware switches on the front of the module or using the mailbox command SET_NODE_ADDRESS. It is also possible to read the state of the switches, allowing the application to manipulate the switch value before initialisation (see 3-3 Read Switch Setting (READ_SWITCH_SETTING) ). Node address restrictions: Node address 0 is reserved for the fieldbus control system (e.g. the PLC) Node address 63 is reserved for configuration and diagnostic terminals Addresses 1-62 are used for connecting industrial peripheral devices to FIPIO. These devices must be declared in the remote I/O configuration of the PLC that controls the process. Addresses can only be used if supported by the fieldbus control system. Baud Rate The baud rate is fixed to the standard FIPIO baudrate 1Mbit/s. Identity Customization The module can be customized to appear as a vendor specific implementation rather than a generic AnyBus-S module. This is done using the mailbox command SET_IDENT_INFO (see 3-13 Set Identification Info (SET_IDENT_INFO) ). The following information can be changed: Vendor Name: Name of the manufacturer of the product (20 characters) Model Name: Name of the model of the device (20 characters) By default, the module identifies itself as follows: Vendor Name: HMS Ind. Networks Model Name: AnyBus-S FIPIO Status Handling Standard Status Byte The Standard Status byte is used to signal status information to the FIPIO master. All bits in the Standard Status byte except bit 6 are available to the application, see 3-12 Set Standard Status (SET_STANDARD_STATUS). Specific Status Buffer (FEDP profile only) In the FEDP profile there are 16 bytes available for sending specific status. The meaning of the data has to be defined for each device. The application can access the specific status buffer using the SET_SPECIFIC_STATUS command.

10 Basic Operation 2-2 Profiles and Classes The module supports all standard FIPIO profiles and classes. The profile and class determines the size of the I/O area. The available profiles and classes are described below. FRDP - FIPIO Reduced Device Profile Data processed: - Reading of inputs - Controlling of outputs Class 0: Class 1: Class 2: 2 words 2 words 2 words 2 words 2 words 2 words Configuration: words Adjustment: words Commands: - Standard command - Specific command Diagnostics: - Standard status - Specific status byte - 1 byte - 1 byte - 1 byte - 1 byte - FSDP - FIPIO Standard Device Profile Data processed: - Reading of inputs - Controlling of outputs Class 0: Class 1: Class 2: 8 words 8 words 8 words 8 words 8 words 8 words Configuration: words Adjustment: words Commands: - Standard command - Specific command Diagnostics: - Standard status - Specific status byte - 1 byte - 1 byte - 1 byte - 1 byte - FEDP - FIPIO Extended Device Profile Data processed: - Reading of inputs - Controlling of outputs Class 0: Class 1: Class 2: 32 words 32 words 32 words 32 words 32 words 32 words Configuration: words Adjustment: words Commands: - Standard command - Specific command Diagnostics: - Standard status - Specific status byte 8 words 1 byte 8 words 1 byte 8 words 1 byte 8 words 1 byte 8 words

11 Basic Operation 2-3 Parameter Data Handling The application must poll bits 1, 2 and 3 in the Fieldbus Specific Area (see 4-1 Fieldbus Specific Area (0x640-0x7BF) ) periodically to see if any new parameter data has been received by the module. If new parameter data has been received, the application should read and evaluate it, and then either accept or reject the it using the appropriate mailbox command. There are three types of parameter data: Command Data Adjustment Data Configuration Data (Consult the FIPIO documentation for more information) Command Data Indication Bit: CNT Related mailbox functions: GET_SPECIFIC_COMMAND ACCEPT_SPECIFIC_COMMAND Flowchart Example: (Configuration Data) CNF-bit set? Yes Start Get Configuration Data (GET_CONFIGURATION) No Adjustment Data Examine the received data Indication Bit: ADJ Related mailbox functions: GET_ADJUSTMENT ACCEPT_ADJUSTMENT Configuration Data Yes Configuration Data OK? No Indication Bit: CNF Related mailbox functions: GET_CONFIGURATION ACCEPT_CONFIGURATION Note: If no Configuration Data has been received/accepted, or if the configuration has been reset, the CE bit in the Fieldbus Specific Area will be set. Accept data (ACCEPT_CONFIGURATION) Reject data (ACCEPT_CONFIGURATION) End

12 Chapter 3 Mailbox Interface This chapter describes the fieldbus specific mailbox commands in the module. Consult the AnyBus-S Design Guide for more information regarding mailbox functionality. Fault and Status Information When a mailbox command cannot be processed the Message Information register in the header of the response will indicate that an error occurred. Consult the AnyBus-S Design Guide for more information. If the error code is Invalid Other (Fh), extended error information is available in the Fault Information register (Extended word 8). The fault codes in the Fault Information register are: Register Value Name 0001h Invalid Profile Invalid FIPIO Profile 0002h Invalid Class Invalid FIPIO Class 0003h No data available No data available

13 Mailbox Interface 3-2 Basic Settings Set Node Address (SET_NODE_ADDRESS) This command is used to set the node address. If this command is sent, the physical switch setting will be ignored. Note: This command can only be sent during module initialisation. Parameter Command initiator Application Command Name SET_NODE_ADDRESS Message type 02h Command number 0001h Fragmented No Extended Header data - Command data Node address, range Response data The response indicates if the command was accepted. The response data is a copy of the command data. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0001h 0001h SET_NODE_ADDRESS Data size 0001h 0001h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word Message data byte 1 Node Address Node Address Range 0-255

14 Mailbox Interface 3-3 Read Switch Setting (READ_SWITCH_SETTING) This function returns the physical setting of the node address switches. Parameter Command initiator Application Command Name READ_SWITCH_SETTING Message type 02h Command number 0002h Fragmented No Extended Header data - Command data - Response data Switch setting. The response indicates if the command was accepted. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0002h 0002h READ_SWITCH_SETTING Data size 0000h 0001h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word Message data byte 1 Switch setting

15 Mailbox Interface 3-4 Set Profile and Class (SET_PROFILE_CLASS) This command sets the FIPIO profile and class. The FIPIO profile limits the number of I/O bytes that can be used, and the class affects configuration data etc. (Consult the FIPIO Standard Profiles Reference Manual for more information about profiles and classes). It is not possible to initialise the module with more I/O than the profile supports. The default setting is profile FEDP, class 0. (See 2-2 Profiles and Classes for more information about the available profiles and classes) Note: This command can only be sent during module initialisation. Parameter Command initiator Command Name Message type Command number Fragmented Extended Header data Command data Response data Application SET_PROFILE_CLASS 02h 0003h No Extended fault information may be returned in the header of the response. FIPIO Profile & Class The response indicates if the command was accepted. The response data is a copy of the command data. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0003h 0003h SET_PROFILE_CLASS Data size 0002h 0002h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data byte 1 Profile Profile FIPIO Profile Message data byte 2 Class Class FIPIO Class number Profile FRDP = 0x06, FSDP = 0x00, FEDP = 0x02 Class Class 0 = 0x00, Class 1 = 0x01, Class 2 = 0x02

16 Mailbox Interface 3-5 Configuration Data Get Configuration (GET_CONFIGURATION) This function returns the received configuration data. New configuration data is indicated in the fieldbus specific area. When new configuration data has been read and verified by the application, it must be accepted or rejected by sending the ACCEPT_CONFIGURATION command. (For more information, see 2-3 Parameter Data Handling ) Notes: This function can only be used when the module has been initialised as a Class 2 module. If no new configuration data is available, the response will contain extended error information. Parameter Command initiator Application Command Name GET_CONFIGURATION Message type 02h Command number 0006h Fragmented No Extended Header data Extended fault information may be returned in the header of the response. Command data - Response data The response contains the new configuration data. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0006h 0006h GET_CONFIGURATION Data size 0000h (NN bytes of data) Size depends on FIPIO profile Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data byte 1 Configuration data byte Message data byte n Configuration data byte NN Profile & Class FRDP, Class 2 FSDP, Class 2 FEDP, Class 2 Message Data Size / Configuration Data Size 16 words (32 bytes) 16 words (32 bytes) 30 words (60 bytes)

17 Mailbox Interface 3-6 Accept Configuration (ACCEPT_CONFIGURATION) This command is used to accept or reject a configuration previously received using the GET_CONFIGURATION function. (For more information, see 2-3 Parameter Data Handling ) Parameter Command initiator Command Name Message type Command number Fragmented Extended Header data Command data Response data Application ACCEPT_CONFIGURATION 02h 0009h No Extended fault information may be returned in the header of the response. Flag indicating whether the configuration shall be accepted or rejected The response indicates if the command was accepted. The response data is a copy of the command data. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0009h 0009h ACCEPT_CONFIGURATION Data size 0001h 0001h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data byte 1 Accept / Reject Accept / Reject Accept / Reject 01h: Accept configuration data 00h: Reject configuration data

18 Mailbox Interface 3-7 Adjustment Data Get Adjustment Data (GET_ADJUSTMENT) This function returns the received adjustment data. New adjustment data is indicated in the fieldbus specific area. After the adjustment data has been read and verified by the application, it must be accepted or rejected by sending an ACCEPT_ADJUSTMENT mailbox command. (For more information, see 2-3 Parameter Data Handling ) Note: This function can only be used when the module has been initialised as a Class 2 module. If no new adjustment data is available, the response will contain extended error information. Parameter Command initiator Application Command Name GET_ADJUSTMENT Message type 02h Command number 0007h Fragmented No Extended Header data Extended fault information may be returned in the header of the response. Command data - Response data The response contains the new adjustment data. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0007h 0007h GET_ADJUSTMENT Data size 0000h (NN bytes of data) Size depends on FIPIO profile Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data byte 1 Adjustment data byte Message data byte n Adjustment data byte NN Profile & Class FRDP, Class 2 FSDP, Class 2 FEDP, Class 2 Message Data Size / Adjustment Data Size 32 words (64 bytes) 32 words (64 bytes) 30 words (60 bytes)

19 Mailbox Interface 3-8 Accept Adjustment Data (ACCEPT_ADJUSTMENT) This command is used to accept or reject a configuration previously received using the GET_ADJUSTMENT function. (For more information, see 2-3 Parameter Data Handling ) Parameter Command initiator Command Name Message type Command number Fragmented Extended Header data Command data Response data Application ACCEPT_ADJUSTMENT 02h 000Ah No Extended fault information may be returned in the header of the response. Flag indicating whether the configuration shall be accepted or rejected The response indicates if the command was accepted. The response data is a copy of the command data. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 000Ah 000Ah ACCEPT_ADJUSTMENT Data size 0001h 0001h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data byte 1 Accept / Reject Accept / Reject Accept / Reject 01h: Accept adjustment data 00h: Reject adjustment data

20 Mailbox Interface 3-9 Command Data Get Specific Command (GET_SPECIFIC_COMMAND) This function returns the received specific command (FEDP Class 1 & 2 only). New specific command data is indicated in the fieldbus specific area. After a specific command has been read and checked, it must be accepted or rejected by sending an ACCEPT_SPECIFIC_COMMAND mailbox command. (For more information, see 2-3 Parameter Data Handling ) Note: The specific command data comes from the FB_CONTROL variable, which is consumed by the device. This variable contains a byte called validity of specific commands. If this byte is zero, it means that a specific command data is not invalid and thus not considered to be received by the module. Parameter Command initiator Application Command Name GET_SPECIFIC_COMMAND Message type 02h Command number 0008h Fragmented No Extended Header data Extended fault information may be returned in the header of the response. Command data - Response data The response indicates if the command was accepted. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0008h 0008h GET_SPECIFIC_COMMAND Data size 0000h 0010h 16 bytes of data (8 words) Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data word 1 Specific Command word 1 Specific Command word 1 Message data word 2 Specific Command word 2 Specific Command word Message data word 8 Specific Command word 8 Specific Command word 8

21 Mailbox Interface 3-10 Accept Specific Command (ACCEPT_SPECIFIC_COMMAND) This command is used to accept or reject specific command data previously received using the GET_SPECIFIC_COMMAND function. (For more information, see 2-3 Parameter Data Handling ) Parameter Command initiator Command Name Message type Command number Fragmented Extended Header data Command data Response data Application ACCEPT_SPECIFIC_COMMAND 02h 000Bh No Extended fault information may be returned in the header of the response. Flag indicating whether the configuration shall be accepted or rejected The response data contains a copy of the command data. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 000Bh 000Bh ACCEPT_SPECIFIC_COMMAND Data size 0001h 0001h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data byte 1 Accept / Reject Accept / Reject Accept / Reject 01h: Accept specific command data 00h: Reject specific command data

22 Mailbox Interface 3-11 Status Handling Set Specific Status (SET_SPECIFIC_STATUS) Set the device specific status, only valid for the FEDP profile. Parameter Command initiator Application Command Name SET_SPECIFIC_STATUS Message type 02h Command number 0005h Fragmented No Extended Header data Extended fault information may be returned in the header of the response. Command data - Response data The response data contains a copy of the command data. Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0005h 0005h SET_SPECIFIC_STATUS Data size 0010h 0010h 16 bytes of data (8 words) Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data word 1 Specific status word 1 Specific status word 1 Message data word 2 Specific status word 2 Specific status word 2 Message data word 3 Specific status word 3 Specific status word 3 Message data word 4 Specific status word 4 Specific status word 4 Message data word 5 Specific status word 5 Specific status word 5 Message data word 6 Specific status word 6 Specific status word 6 Message data word 7 Specific status word 7 Specific status word 7 Message data word 8 Specific status word 8 Specific status word 8

23 Mailbox Interface 3-12 Set Standard Status (SET_STANDARD_STATUS) The module automatically uses the Standard Status bits to indicates run time errors to the FIPIO master. Using this command, the application can also access these bits. All bits except bit 6 are available to the application. (The meanings of these bits are described in the table below.) Parameter Command initiator Application Command Name SET_STANDARD_STATUS Message type 02h Command number 000Ch Fragmented No Extended Header data - Command data Standard status data Response data The response data contains a copy of the command data Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 000Ch 000Ch SET_STANDARD_STATUS Data size 0001h 0001h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word Message data byte 1 Standard Status byte Standard Status byte (bitfield, see below) Standard Status Byte Bit Name 7 Application Fault Incorrect control operation 6 a Communication Fault Communication is no longer operational 5 Hardware Configuration Fault One of the device modules is not compatible with each other 4 Internal Fault Hardware failure of the device 3 External Fault 1 Specific fault number 1 (External power supply fault) 2 External Fault 2 Specific fault number 2 (The terminal block is not connected) 1 External Fault 3 Specific fault number 3 0 External Fault 4 Specific fault number 4 a. This bit cannot be set by the application

24 Mailbox Interface 3-13 Identification Set Identification Info (SET_IDENT_INFO) This command is used to set the Vendor Name and Model Name of the module. Parameter Command initiator Application Command Name SET_IDENT_INFO Message type 02h Command number 0004h Fragmented No Extended Header data - Command data Vendor name and Model name. Both entries must be 20 characters long, pad with spaces if necessary. Response data The response data contains a copy of the command data Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 0004h 0004h SET_IDENT_INFO Data size 0028h 0028h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word Message data bytes 1-20 Vendor Name [ ] Vendor Name [ ] Message data bytes Model Name [ ] Model Name [ ]

25 Mailbox Interface 3-14 Communication Set Promptness Time (SET_PROMTNESS_TIME) This command sets the maximum allowed time between received output data packets before the module times out and indicates off line. The default value is 256ms. Note: This command can only be send during module initialisation. Parameter Command initiator Command Name Message type Command number Fragmented Extended Header data Command data Response data Application SET_PROMPTNESS_TIME 02h 000Dh No Extended fault information may be returned in the header of the response. Promptness time (See explanation below) The response data contains a copy of the command data Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 000Dh 000Dh SET_PROMPTNESS_TIME Data size 0001h 0001h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data byte 1 Promptness Time Promptness Time See explanation below Promptness Time 01h: 32ms 02h: 64ms 03h: 256ms 04h: 1s 05h: 4s

26 Mailbox Interface 3-15 Set Channel Fault (SET_CHANNEL_FAULT) This command sets the channel fault byte, the first byte in the APPLICATION_PROCESS_STATUS, produced by the module. A value of zero indicates that the input values are valid and can be used by the device consuming the variable. The default value is 0. Parameter Command initiator Command Name Message type Command number Fragmented Extended Header data Command data Response data Application SET_CHANNEL_FAULT 02h 000Eh No Extended fault information may be returned in the header of the response. Channel Fault value The response data contains a copy of the command data Command and response layout: Command Expected response Message ID (ID) (ID) Message information 4002h 0002h Command 000Eh 000Eh SET_CHANNEL_FAULT Data size 0001h 0001h Frame count 0001h 0001h Frame number 0001h 0001h Offset high 0000h 0000h Offset low 0000h 0000h Extended word Extended word Extended word Extended word Extended word Extended word Extended word Extended word 8 - Fault information Extended fault information Message data byte 1 Channel fault value Channel fault value

27 Chapter 4 Fieldbus Specific Registers Fieldbus Specific Area (0x640-0x7BF) This area provides status information from the FIPIO network. Address Register 640h - 641h FIP Received Data Bitfield containing misc. status flags, see below. 642h - 7BFh Reserved Reserved, do not use b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 CE CNT ADJ CNF 0x640 (MSB) 0x641 (LSB) CE - Configuration Empty This bit indicates that no Configuration Data has been received/accepted, or that the configuration has been reset. 1: Configuration is empty 0: - CNT - Specific Command Data The application must poll this bit periodically to see if new Command Data has been received by the module. If new Command Data has arrived, the data must be evaluated by the application. The application can then either choose to accept or reject the received data. This is handled through mailbox commands, see 3-9 Command Data. 1: New Command Data received 0: - ADJ - Adjustment Data The application must poll this bit periodically to see if new Adjustment Data has been received by the module. If new Adjustment Data has arrived, the data must be evaluated by the application. The application can then either choose to accept or reject the received data. This is handled through mailbox commands, see 3-7 Adjustment Data. 1: New Adjustment Data received 0: - CNF - Configuration Data The application must poll this bit periodically to see if new Configuration Data has been received by the module. If new Configuration Data has arrived, the data must be evaluated by the application. The application can then either choose to accept or reject the received data. This is handled through mailbox commands, see 3-5 Configuration Data. 1: New Configuration Data received 0: - Fieldbus Type (0x7CC - 0x7CDh) The fieldbus type value for AnyBus-S FIPIO is 0x0035.

28 Appendix A Connectors Application Connector The application connector features a standard AnyBus-S 2kbyte parallel DPRAM interface. (Consult the general AnyBus-S Parallel Design Guide for more information.) Fieldbus Interface The module supports both 9-pin D-sub connectors and 2mm board to board connectors on the fieldbus interface. 9-pin D-sub (Male) Pin Signal Housing PE A (D+) 7 B (D-) 8 B (D-) 9 A (D+) Male mm Board to Board Pin Signal 1 PE A (D+) 5 B (D-) 6-7 B (D-) 8 A (D+)

29 Appendix B Mechanical Specification Measurements, PCB The PCB is designed according to the AnyBus-S specification A Ø0.8 Ø 0.9 3x Ø A Ø A-A

30 Mechanical Specification B-2 Measurements, Connectors & Switches Standard Configuration Ø Ø 2.8 Ø 5.9 6,4-12,2mm

31 Appendix C Electrical Characteristics Supply Voltage Both the module electronics and the fieldbus interface requires a regulated 5V DC power supply. For more information regarding power requirements, consult the AnyBus-S Design Guide. Power Consumption The total maximum power consumption from the application side is 300mA Protective Earth A PE-connection is available on one of the mounting holes according to the AnyBus-S specification.

32 Appendix D Environmental Specification Temperature Operating +0 to +70 degrees Celsius Test performed according to IEC and IEC Non Operating -15 to +85 degrees Celsius Test performed according to IEC and IEC Relative Humidity The product is designed for a relative humidity of 5 to 95% non-condensing. Test performed according to IEC EMC compliance Emission According to EN :1993 Tested per 55022:1997, class A, radiated Immunity According to EN :1999 Tested per EN :1995 EN :1996 EN :1995 EN :1995 EN :1996

33

Anybus-S CC-Link. Fieldbus Appendix. Rev HMS Industrial Networks AB. Germany Japan Sweden U.S.A UK

Anybus-S CC-Link. Fieldbus Appendix. Rev HMS Industrial Networks AB. Germany Japan Sweden U.S.A UK Fieldbus Appendix Anybus-S CC-Link Rev. 1.51 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK +49-721 - 96472-0 +81-45 - 478-5340 +46-35 - 17 29 20 +1-773 - 404-3486 +44-1908 - 359301 sales-ge@hms-networks.com

More information

Fieldbus Appendix Anybus-S Interbus 2Mbit/s Fibre Optic

Fieldbus Appendix Anybus-S Interbus 2Mbit/s Fibre Optic Fieldbus Appendix Anybus-S Interbus 2Mbit/s Fibre Optic SCM-1200-144 Rev. 1.03 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan

More information

FIP IO Slave. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting DevicesTM

FIP IO Slave. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting DevicesTM X-gateway Interface Addendum FIP IO Slave Doc: HMSI-27-258 Rev: 2.00 Connecting DevicesTM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing

More information

Anybus -S CANopen. Fieldbus Appendix. ABS-COP-3 Rev HMS Industrial Networks AB. Germany Japan Sweden U.S.A UK

Anybus -S CANopen. Fieldbus Appendix. ABS-COP-3 Rev HMS Industrial Networks AB. Germany Japan Sweden U.S.A UK Fieldbus Appendix Anybus -S CANopen ABS-COP-3 Rev. 2.02 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 + 44 (0) 1908-359301

More information

User Guide AnyBus NetTool for DeviceNet

User Guide AnyBus NetTool for DeviceNet User Guide AnyBus NetTool for DeviceNet Rev. 1.00 HMS Industrial Networks Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-2271 sales-ge@hms-networks.com

More information

AnyBus -X Modbus Plus Slave

AnyBus -X Modbus Plus Slave Network Interface Addendum AnyBus -X Modbus Plus Slave Doc.Id. SCM-1200-069 Rev. 1.02 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35

More information

Network Interface Appendix Anybus -CompactCom Passive RS-485/422

Network Interface Appendix Anybus -CompactCom Passive RS-485/422 Network Interface Appendix Anybus -CompactCom Passive RS-485/422 Rev. 1.01 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan

More information

X-gateway Interface Addendum DeviceNet Scanner Interface

X-gateway Interface Addendum DeviceNet Scanner Interface X-gateway Interface Addendum DeviceNet Scanner Interface Rev. 1.10 HMS Industrial Networks AB Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 ge-sales@hms-networks.com

More information

ControlNet Adapter Interface

ControlNet Adapter Interface X-gateway Interface Addendum ControlNet Adapter Interface Rev. 1.10 HMS Industrial Networks AB Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 ge-sales@hms-networks.com

More information

Fieldbus Appendix ANYBUS -S LonWorks

Fieldbus Appendix ANYBUS -S LonWorks Fieldbus Appendix ANYBUS -S LonWorks HMS INDUSTRIAL NETWORKS AB PIELEFELTSGATAN 93-95 S - 302 50 HALMSTAD SWEDEN PHONE: +46 35 17 29 00 FAX: +46 35 17 29 09 e-mail: info@hms-networks.com web: www.hms-networks.com

More information

User Manual Anybus Serial Server

User Manual Anybus Serial Server User Manual Anybus Serial Server Rev. 1.20:1 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 + 44 (0) 1908-359301 ge-sales@hms-networks.com

More information

CANopen Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

CANopen Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM X-gateway Interface Addendum CANopen Slave Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing address: Box 4126, 300

More information

EtherCAT Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

EtherCAT Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM X-gateway Interface Addendum EtherCAT Slave Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing address: Box 4126, 300

More information

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM X-gateway Interface Addendum PROFIBUS Slave Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing address: Box 4126, 300

More information

Fieldbus Appendix Anybus -S ControlNet

Fieldbus Appendix Anybus -S ControlNet Fieldbus Appendix Anybus -S ControlNet Doc.Id. SCM-1200-009 Rev. 2.02 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20

More information

Network Interface Appendix Anybus -S CC-Link IE Field Network

Network Interface Appendix Anybus -S CC-Link IE Field Network Network Interface Appendix Anybus -S CC-Link IE Field Network Rev. 1.10 Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing

More information

X-gateway Interface Addendum CC-Link Slave Interface

X-gateway Interface Addendum CC-Link Slave Interface X-gateway Interface Addendum CC-Link Slave Interface Doc: HMSI-27-244, Rev: 2.00 Connecting DevicesTM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks

More information

Network Interface Appendix Anybus -CompactCom DeviceNet

Network Interface Appendix Anybus -CompactCom DeviceNet Network Interface Appendix Anybus -CompactCom DeviceNet Rev. 1.06 HMS Industrial Networks AB Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 ge-sales@hms-networks.com

More information

Anybus X-gateway LonWorks Interface

Anybus X-gateway LonWorks Interface Network Interface Addendum Anybus X-gateway LonWorks Interface Rev. 1.10 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29

More information

Anybus-S FL-NET. Fieldbus Appendix. Rev Doc.Id. SCM HMS Industrial Networks AB. Germany Japan Sweden U.S.A. France Italy China

Anybus-S FL-NET. Fieldbus Appendix. Rev Doc.Id. SCM HMS Industrial Networks AB. Germany Japan Sweden U.S.A. France Italy China Fieldbus Appendix Rev. 1.04 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-312 - 829-0601 + 33-3 89 32 76 76 + 39-347

More information

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH Anybus X-gateway PROFIBUS Master Interface NETWORK GUIDE SCM-1202-104 EN 1.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS

More information

User Manual Anybus Modbus TCP/RTU Gateway

User Manual Anybus Modbus TCP/RTU Gateway User Manual AB7702 Rev. 2.01 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad, Sweden E-mail: info@hms-networks.com

More information

REFERENCE GUIDE HMSI ENGLISH

REFERENCE GUIDE HMSI ENGLISH Anybus CompactCom Starter Kit REFERENCE GUIDE HMSI-27-224 2.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks

More information

User Manual AnyBus Communicator for Profibus

User Manual AnyBus Communicator for Profibus User Manual AnyBus Communicator for Profibus Rev. 2.02 HMS Industrial Networks AB Germany Japan Sweden U.S.A +49-721 - 96472-0 +81-45 - 478-5340 +46-35 - 17 29 20 +1-773 - 404-3486 sales-ge@hms-networks.com

More information

Anybus CompactCom Starter Kit REFERENCE GUIDE

Anybus CompactCom Starter Kit REFERENCE GUIDE Anybus CompactCom Starter Kit REFERENCE GUIDE HMSI-27-224 EN 2.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial

More information

ControlNet Adapter. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting Devices TM

ControlNet Adapter. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting Devices TM X-gateway Interface Addendum ControlNet Adapter Doc: HMSI-27-257 Rev: 2.00 Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks

More information

AnyBus-PCI Profibus DPV1 Master

AnyBus-PCI Profibus DPV1 Master AnyBus-PCI Profibus DPV1 Master Package Contents The AnyBus-PCI Profibus DPV1 Master package consists of the following items: Anybus-PCI Profibus DPV1 Master card This installation leaflet CD-ROM containing

More information

Anybus-IC DeviceNet. Fieldbus Appendix. Doc. Id. HMSI Rev Connecting Devices TM

Anybus-IC DeviceNet. Fieldbus Appendix. Doc. Id. HMSI Rev Connecting Devices TM Fieldbus Appendix Doc. Id. HMSI-168-68 Rev. 2.01 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad, Sweden E-mail:

More information

X-gateway Interface Addendum DeviceNet Scanner

X-gateway Interface Addendum DeviceNet Scanner X-gateway Interface Addendum DeviceNet Scanner Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing address: Box 4126,

More information

ANYBUS-S MODBUS PLUS

ANYBUS-S MODBUS PLUS FIELDBUS APPENDIX ANYBUS-S MODBUS PLUS HMS INDUSTRIAL NETWORKS AB STATIONSGATAN 37 S - 302 45 HALMSTAD SWEDEN PHONE: +46 35 17 29 00 FAX: +46 35 17 29 09 e-mail: info@hms.se web: www.anybus.com Revision

More information

Anybus CompactCom 40 PROFIBUS DP-V0/DP-V1 NETWORK GUIDE

Anybus CompactCom 40 PROFIBUS DP-V0/DP-V1 NETWORK GUIDE Anybus CompactCom 40 PROFIBUS DP-V0/DP-V1 NETWORK GUIDE HMSI-27-210-EN 2.3 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS

More information

Anybus Communicator for LonWorksLWTool

Anybus Communicator for LonWorksLWTool User Manual Anybus Communicator for LonWorksLWTool Rev. 1.1 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China +49 +81 +46 +1 +33 +39 +86-721 96472 0-45 478 5340-35 17 29 20-312

More information

Network Interface Appendix Anybus CompactCom PROFIBUS DP-V0

Network Interface Appendix Anybus CompactCom PROFIBUS DP-V0 Network Interface Appendix Anybus CompactCom PROFIBUS DP-V0 Rev. 1.02 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37,

More information

Anybus X-gateway USER MANUAL

Anybus X-gateway USER MANUAL Anybus X-gateway USER MANUAL HMSI-27-262 3.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any

More information

Network Guide Anybus CompactCom 40 PROFIBUS DP-V0/DP-V1

Network Guide Anybus CompactCom 40 PROFIBUS DP-V0/DP-V1 Network Guide Anybus CompactCom 40 PROFIBUS DP-V0/DP-V1 Rev. 1.30 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad,

More information

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH Anybus Communicator IIoT STARTUP GUIDE ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any inaccuracies

More information

Anybus X-gateway Modbus-TCP Modbus RTU

Anybus X-gateway Modbus-TCP Modbus RTU User Manual Anybus X-gateway Modbus-TCP Modbus RTU Rev. 1.00 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad,

More information

D485 Modbus to DeviceNet Converter Instruction Manual

D485 Modbus to DeviceNet Converter Instruction Manual GE Consumer & Industrial D485 Modbus to DeviceNet Converter Instruction Manual Manual P/N: 1601-0235-A1 Manual Order Code: GEK-113195 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue, Markham,

More information

APPLICATION NOTE: Reading/writing data from Anybus-S EtherNet/IP using ControlLogix5000 MSG instruction. HMS Industrial Networks

APPLICATION NOTE: Reading/writing data from Anybus-S EtherNet/IP using ControlLogix5000 MSG instruction. HMS Industrial Networks APPLICATION NOTE: Reading/writing data from Anybus-S EtherNet/IP using ControlLogix5000 MSG instruction HMS Industrial Networks Revision Notes Date: Revision: Notes: Responsible 2003-08-22 0.10 Document

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3

More information

Anybus X-gateway Modbus-TCP Modbus-TCP

Anybus X-gateway Modbus-TCP Modbus-TCP User Manual Anybus X-gateway Modbus-TCP Modbus-TCP Rev. 1.00 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad,

More information

Network Guide Anybus CompactCom 40 DeviceNet

Network Guide Anybus CompactCom 40 DeviceNet Network Guide Anybus CompactCom 40 DeviceNet Rev. 1.20 Connecting Devices TM HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN HMS Industrial Networks Mailing address: Box

More information

PROFIBUS-DP MASTER MANUAL. HMS FIELDBUS SYSTEMS AB Pilefeltsgatan S Halmstad SWEDEN. Doc. No. PDP-M-0.993

PROFIBUS-DP MASTER MANUAL. HMS FIELDBUS SYSTEMS AB Pilefeltsgatan S Halmstad SWEDEN. Doc. No. PDP-M-0.993 MANUAL PROFIBUS-DP MASTER Doc. No. PDP-M-0.993 HMS FIELDBUS SYSTEMS AB Pilefeltsgatan 93-95 S - 302 50 Halmstad SWEDEN Phone: +46-35 172 900 FAX: +46-35 172 909 e-mail: info@hms.se www: www.hms.se 1. Introduction...

More information

User Manual Anybus Communicator for DeviceNet

User Manual Anybus Communicator for DeviceNet User Manual Anybus Communicator for DeviceNet Doc. Id. SCM-1200-098 Rev. 3.01 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan

More information

HARDWARE MANUAL ENGLISH

HARDWARE MANUAL ENGLISH USB-to-CAN V2 Plugin HARDWARE MANUAL ENGLISH HMS Technology Center Ravensburg GmbH Helmut-Vetter-Straße 2 88213 Ravensburg Germany Tel.: +49 751 56146-0 Fax: +49 751 56146-29 Internet: www.hms-networks.de

More information

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE Anybus X-gateway PROFINET IRT (2.32) Interface NETWORK GUIDE SCM-1202-028-EN 1.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform

More information

User Manual Anybus Communicator for CANopen

User Manual Anybus Communicator for CANopen User Manual Anybus Communicator for CANopen Doc. Id. SCM-1200-099 Rev. 3.01 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan

More information

BNI IOL A027 BNI IOL A027

BNI IOL A027 BNI IOL A027 BNI IOL-771-000-A027 BNI IOL-772-000-A027 IO-Link Version 1.1 Universel IO-Link Interface With undervoltage / broken coil detection User s Guide Inhalt 1 Notes to the user 2 1.1. About this guide 2 1.2.

More information

Anybus X-gateway Modbus-TCP PROFINET

Anybus X-gateway Modbus-TCP PROFINET User Manual Anybus X-gateway Modbus-TCP PROFINET Rev. 1.00 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad,

More information

BNI IOL K006. IO Link Sensorhub digital User s Guide

BNI IOL K006. IO Link Sensorhub digital User s Guide BNI IOL-104-000-K006 BNI IOL-102-000-K006 IO Link Sensorhub digital User s Guide Content 1 Notes to the User 2 1.1. About this guide 2 1.2. Structure 2 1.3. Typographical conventions 2 Enumerations 2 Actions

More information

User Manual Anybus Communicator CAN Modbus RTU

User Manual Anybus Communicator CAN Modbus RTU User Manual Anybus Communicator CAN Modbus RTU Doc.Id. HMSI-168-64 Rev. 1.20 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan

More information

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide BNI IOL106000K006 BNI IOL106S01K006 BNI IOL106S01K006C01 User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions

More information

User Manual Anybus Communicator for EtherCAT

User Manual Anybus Communicator for EtherCAT User Manual Anybus Communicator for EtherCAT Doc. Id. HMSI-168-95 Rev. 3.02 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan

More information

Ethernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01

Ethernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01 Anybus X-gateway Ethernet to J1939 Installation Guide AB7665 Part no. SP0863 Rev. 1.01 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 +

More information

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax

More information

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

User Manual Anybus Communicator CAN Modbus-TCP

User Manual Anybus Communicator CAN Modbus-TCP User Manual Anybus Communicator CAN Modbus-TCP Rev. 1.20 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad, Sweden

More information

Project Name Project No AnyBus Master DeviceNet Henrik Arleving, HeA

Project Name Project No AnyBus Master DeviceNet Henrik Arleving, HeA Henrik Arleving, HeA 2003-04-17 Appendix for AnyBus-M DeviceNet Daniel Rosén 1 (65) ANYBUS-M DEVICENET MASTER/SCANNER APPENDIX 1.02 Appendix for AnyBus-M DeviceNet Daniel Rosén 2 (65) s Rev. Chapter Author

More information

User Manual Anybus X-gateway CANopen DeviceNet

User Manual Anybus X-gateway CANopen DeviceNet User Manual Anybus X-gateway CANopen DeviceNet Rev. 1.00 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-312 - 829-0601

More information

Anybus CompactCom 40 Diagnostic Events for PROFIBUS APPLICATION NOTE

Anybus CompactCom 40 Diagnostic Events for PROFIBUS APPLICATION NOTE Anybus CompactCom 40 Diagnostic Events for PROFIBUS APPLICATION NOTE SCM-1202 025 1.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please

More information

User Manual Anybus Communicator for Modbus Plus

User Manual Anybus Communicator for Modbus Plus User Manual Anybus Communicator for Modbus Plus Doc. Id. SCM-1200-093 Rev. 3.01 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan

More information

BNI IOL Z012. User s Guide

BNI IOL Z012. User s Guide BNI IOL205000Z012 User s Guide Balluff Network Interface / BNI IOL205000Z012 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations

More information

User Manual Anybus Communicator CAN ControlNet

User Manual Anybus Communicator CAN ControlNet User Manual Anybus Communicator CAN ControlNet Rev. 1.10 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad, Sweden

More information

Operation manual. HDOM-Profibus-V0. More options please visit;www.veikong-electric.com

Operation manual. HDOM-Profibus-V0. More options please visit;www.veikong-electric.com Operation manual HDOM-Profibus-V0 More options please visit;www.veikong-electric.com Contents 1 Introduction... 1 1.1 Product description... 1 1.2 HDOM-Profibus-V0 label... 1 1.3 Technical specifications...

More information

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide BNI PBS-104-000-Z001 BNI PBS-102-000-Z001 BNI PBS-302-000-Z001 Quick start guide Content 1 Notes for the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typografical conventions 2 1.3.1 Enumerations

More information

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL302002Z046 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL302002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical

More information

Anybus CompactCom 30 SOFTWARE DESIGN GUIDE

Anybus CompactCom 30 SOFTWARE DESIGN GUIDE Anybus CompactCom 30 SOFTWARE DESIGN GUIDE HMSI-168-97 3.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks

More information

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English GIN-SAM4 Hardware User Manual Version: 1.02 Date: 08.06.2017 Language: English Table of Contents 1. General 4 1.1. About this manual 4 1.2. Sales and Service 4 1.2.1. Manufacturer 4 1.3. Copyright 4 1.4.

More information

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide BNI PNT-502-105-Z015 IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations

More information

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide BNI PNT-104-105-Z015 BNI PNT-202-105-Z015 BNI PNT-302-105-Z015 BNI PNT-305-105-Z015 IP67 Modules User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical

More information

FC8x. Profibus Communication

FC8x. Profibus Communication Title FC8x Profibus Communication SIEB & MEYER AG Auf dem Schmaarkamp 21 * D-21339 Lüneburg * (Germany) Telephone: +49-4131 - 203-0 * Telefax: +49-4131 - 203-2000 Email: documentation@sieb-meyer.de Internet:

More information

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide BNI IOL104002Z046 IOLink 1.1 Sensor hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL104002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide BNI EIP-202-000-Z016 BNI EIP-202-100-Z016 IP67 Modules, 8 Outputs BNI EIP-206-000-Z016 BNI EIP-206-100-Z016 IP67 Modules, 16 Outputs User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure

More information

BNI IOL-104-S01-Z012-C02

BNI IOL-104-S01-Z012-C02 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical

More information

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide BNI PBS-104-000-Z001 BNI PBS-302-000-Z001 BNI PBS-501-000-Z001 BNI PBS-502-000-Z001 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide BNI PNT-104-105-Z015 IP67 Modules 16 Input User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

Anybus X-gateway Modbus-TCP EtherCAT

Anybus X-gateway Modbus-TCP EtherCAT User Manual Anybus X-gateway Modbus-TCP EtherCAT Rev. 1.00 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad,

More information

Powered Roller Controller for DeviceNet

Powered Roller Controller for DeviceNet PRC-620-090 TECHNICAL DATA Description The Holjeron Powered Roller Controller for use with DeviceNet has the features needed to handle up to four zones in a material handling system. A Brushless DC Powered

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 Notes 2 1.1. Struture of the guide 2 1.2. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2 1.3. Symbols

More information

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide

More information

BIS L x-07-S4

BIS L x-07-S4 BIS L-409-045-00x-07-S4 Quick Guide 41 English www.balluff.com 1 2 3 4 5 Notes to the user 5 1.1 bout this manual 5 1.2 Structure of the manual 5 1.3 Typographical conventions 5 1.4 Symbols 5 1.5 bbreviations

More information

Anybus X-gateway Modbus-TCP Modbus-TCP

Anybus X-gateway Modbus-TCP Modbus-TCP User Manual Modbus-TCP Rev..0 Connecting DevicesTM +$/067$' &+,&$*2.$5/658+( 72.

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

RMx621. Appendix to the operating manual

RMx621. Appendix to the operating manual Appendix to the operating manual RMx621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 to PROFIBUS DP via the RS485 serial interface using the external module (HMS AnyBus Communicator

More information

Anybus CompactCom 40 Diagnostic Events for EtherCAT SCM ENGLISH

Anybus CompactCom 40 Diagnostic Events for EtherCAT SCM ENGLISH Anybus CompactCom 40 Diagnostic Events for EtherCAT SCM-1202 070 1.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial

More information

User Manual Anybus X-gateway CANopen DeviceNet

User Manual Anybus X-gateway CANopen DeviceNet User Manual Anybus X-gateway CANopen DeviceNet Rev. 2.01 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad, Sweden

More information

Anybus X-gateway Modbus-TCP PROFINET

Anybus X-gateway Modbus-TCP PROFINET User Manual Anybus X-gateway Modbus-TCP PROFINET Rev. 1.10 Connecting Devices TM HMS Industrial Networks Mailing address: Box 4126, 300 04 Halmstad, Sweden Visiting address: Stationsgatan 37, Halmstad,

More information

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. MCD Modbus Module Instructions Important User Information INSTALLATION INSTRUCTIONS: MCD MODBUS MODULE Order Code: 175G9000 1. Important User Information Observe all necessary safety precautions when controlling

More information

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE ENGLISH Important User Information Liability Every care has been taken in the preparation of this document.

More information

SBPC-21-PB FifeNet to Profibus Gateway

SBPC-21-PB FifeNet to Profibus Gateway Fife Corporation PO Box 26508, Oklahoma City, OK 73126, U.S.A. Phone: 405.755.1600 / Fax: 405.755.8425 www.fife.com / E-mail: fife@fife.com SBPC-21-PB FifeNet to Profibus Gateway Profibus Operation Manual

More information

SCHMIDT Sensor interface PROFIBUS Instructions for use

SCHMIDT Sensor interface PROFIBUS Instructions for use SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...

More information

Anybus CompactCom. Host Application Implementation Guide. Doc.Id. HMSI Doc. Rev Connecting DevicesTM

Anybus CompactCom. Host Application Implementation Guide. Doc.Id. HMSI Doc. Rev Connecting DevicesTM Anybus CompactCom Doc. Rev. 1.10 Connecting DevicesTM +$/067$' &+,&$*2.$5/658+( 72.

More information

Anybus Communicator PROFINET

Anybus Communicator PROFINET Anybus Communicator PROFINET with Siemens S7-1500 PLC & TIA Portal APPLICATION NOTE SCM-1202-046 1.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document.

More information

RMx621 /FML621. Appendix to the operating manual

RMx621 /FML621. Appendix to the operating manual Appendix to the operating manual RMx621 /FML621 DP-slave module ( PROFIBUS-coupler ) from V2.01.00 Connecting the RMx621 /FML621 to PROFIBUS DP via the RS485 serial interface using the external module

More information

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide BNI IOL102002Z019 IOLink 1.1 sensor hub With extension port User s Guide Balluff Network Interface / IOLink BNI IOL102002Z019 Inhalt 1 Notes for the user 4 1.1. About this manual 4 1.2. Structure of the

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 s 2 1.1. About this guide 2 1.2. Struture of the guide 2 1.3. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references

More information

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide BNI DNT-104-000-Z004 BNI DNT-202-000-Z005 BNI DNT-302-000-Z005 BNI DNT-305-000-Z005 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide BNI PBS-502-001-Z001 IP67 module, Profibus IO-Link Master Short Guide 1 Notes for the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typografical conventions 2 1.3.1 Enumerations 2 1.3.2

More information

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual 1/36 CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual N - Copyright 2011, St Herblain France All rights reserved. Any unauthorized use or copying of the contents or part thereof is

More information