User Guide: PFM 4000 Measuring Instrument - Multisource Version

Size: px
Start display at page:

Download "User Guide: PFM 4000 Measuring Instrument - Multisource Version"

Transcription

1 User Guide: PFM 4000 Measuring Instrument - Multisource Version

2 VUE2B102 Danfoss 11/2008 HEC

3 Contents PFM main features... 5 Introduction... 5 PFM 4000 Multisource components... 6 Switching on and off... 7 Introduction... 7 Start of measuring... 8 Sensor zero setting Quick recording Data recording Two Sensors Measuring for Balancing by the Proportional Method Calculation of valve presetting for a required flow in one branch Calculation of pressure loss on the valve for required flow Working with Projects Starting with projects Creating new project Preparing for project balancing measuring Balancing of basic project...25 Project with Central Pressure Input Balancing calculation of a project with central pressure input - procedure Measuring actual flow Replacement of sintered filters Using of Routers Scheme of Using Routers Operations after PDA clean reset HEC VUE2B102 Danfoss 11/2008

4 Radio card installation PFM4000 Multisource program installation Technical specifications VUE2B102 Danfoss 11/2008 HEC

5 PFM main features Introduction Separated main pressure unit and computing unit based on PDA Wireless communication in ISM band Possible connection up to 10 pressure units Accurate pressure measuring with true differential pressure sensor and 24 bit ADC Hydraulic by-pass for exact small differential pressure measuring PFM 4000 Multisource has been designed for the servicing and hydraulic balancing of most pressurised heating and/or cooling systems. It enables measuring of both under-pressure and over-pressure as well as that of differential pressure within a given system. Furthermore, using differences in pressure between the balancing and measuring elements, the flow through individual branches of the system can be measured, thus allowing the whole system to be balanced. PFM 4000 Multisource has a number of key features that enable easy handling. The apparatus itself consists of two separate units, main pressure unit for measuring and computing unit based on PDA for data analysis. The main pressure is extremely robust with a sturdy frame and sound cover. It comprises a differential pressure meter with an integrated true differential pressure sensor for accurate digital data processing. Owing to the advantages gained by the use of digital technology, the PFM 4000 Multisource is able to External PT-100 thermometer Working with projects Programmable autonomous recording mode Main unit powered by rechargeable Li-Ion battery compensate for inaccuracies normally associated with pressure measurements, such as temperature dependency and non-linearity. In order to increase the accuracy of low pressure measuring and to enable pressure connection deaeration, the main pressure unit is designed with incoming couplers by-pass for hydraulic zero setting. This forms the basis for the accuracy of subsequent measurements. The PFM 4000 Multisource can be supplemented with an external thermometer connected via a coaxial connector. The temperature of the working medium can be easily measured by inserting the thermometer into the differential pressure outputs due to their size compatibility with the balancing valve measuring needles. One of the essential PFM 400 Multisource components for balancing hydraulic systems is a built-in flow meter module. The flow meter works by calculating the flow through a given branch within the system using differences in pressure registered by the measuring element. HEC VUE2B102 Danfoss 11/2008 5

6 PFM 4000 Multisource components I 6 VUE2B102 Danfoss 11/2008 HEC

7 Switching on and off 1. Press ON/OFF button to switch on PFM 4000 Multisource. The sensor switches off automatically 60 minutes after the end of communication with PDA. Introduction. HEC VUE2B102 Danfoss 11/2008 7

8 Start of measuring 1. Insert SD card in the PDA. Run the PFM 4000 Multisource application from Start Menu. Select Measure in the main menu. 2. Tip! Clicking on any underlined text, e.g. Valve, will open change parameter window. 3. Select Menu, Change sensor to connect computing unit to the sensor. 4. Select Search to obtain a list of available sensors. Select desired sensor from the list and confirm by clicking OK. If you use router, router #1means nearest router to PDA. Searching of pressure units do not run via routers. Make sure that you are close to pressure unit during searching. 8 VUE2B102 Danfoss 11/2008 HEC

9 Start of measuring (continued) 5. Sensor Info button displays information about the selected sensor. 6. Click on Valve selection for changing valve type or click on Presetting for changing presetting value. Change medium by clicking on Medium. 7. Select Manufacturer from list box. Then select valve type and click Ok. 8. Input valve presetting and click Ok. HEC VUE2B102 Danfoss 11/2008 9

10 Start of measuring (continued) 9. Select medium from list box and fill in value of concentration. 10. Select flow units from list box. 11. Select temperature units from list box. 12. Select pressure units from list box. 10 VUE2B102 Danfoss 11/2008 HEC

11 Sensor zero setting 1. Should you want to measure small differential pressures of less than 500Pa, the PFM 4000 sensor should be set to zero. measuring position 2. Zero setting is achieved by clicking on Zero button. zero setting position 3. Connect sensor to the system, turn zero valve to horizontal position and continue by clicking OK. 4. Turn zero valve back to vertical position and confirm by clicking OK. HEC VUE2B102 Danfoss 11/

12 Quick recording 1. Measured value can be recorded by clicking on Quick Record button. 2. Input place and name of entry. Data recording 1. Select Records in the main menu. 2. Click on Menu, New button. 12 VUE2B102 Danfoss 11/2008 HEC

13 Data recording (continued) 3. Select recording units. 4. Select place, name, period and number or records. 5. Click OK. The setting will be transmitted to the PFM 4000 Multisource sensor and recording will begin. The recording status will be indicated by PFM 4000 Multisource LED. 6. Clicking on New or Read button during recording will pop up a message. Only answer this at the end of the recording period. HEC VUE2B102 Danfoss 11/

14 Data recording (continued) 7. Data recorded into the sensor can be accessed by clicking on Read button. Clicking on Save button will save data. 8. Enter name and place of file for the read data. For reasons described above, It is recommended to save onto an SD card. 9. Saved data can be accessed by clicking on Open button. 10. When using two sensors, recording can be done on both sensors simultaneously. 14 VUE2B102 Danfoss 11/2008 HEC

15 Two Sensors Measuring for Balancing by the Proportional Method 1. Tap on Proportional measuring button 2. Balancing by proportional method window will open 3. Select reference sensor, for instance in the upper part of the window, by clicking on Sensor link. 4. Select sensor from the branch to be balanced into the lower part of the window. 5. For both branches, set the correct valve and presetting. 6. Flow in both branches will be displayed in the flow window in flow units. 7. Input the requested flow for both branches by clicking l lambda. The display will subsequently change from real to proportional flow expressed as a % of the requested flow. HEC VUE2B102 Danfoss 11/

16 Calculation of valve presetting for a required flow in one branch 1. Click on Calculations button in the main menu. 2. Select valve and enter the current presetting in the branch. Click on Calculate presetting button. 3. Enter the required flow for the branch. 4. Measure the current flow through the branch. 16 VUE2B102 Danfoss 11/2008 HEC

17 Calculation of valve presetting for a required flow in one branch (continued) 5. Close valve and measure the available pressure in the branch. 6. Presetting for the required flow will appear in the Results window. Presetting out of range message will appear if it is not possible to achieve the required flow. Calculation of pressure loss on the valve for required flow 1. Click on Calculations button in the main menu. 2. Select valve and enter the current presetting in the branch. Click on Calculate pressure loss button. HEC VUE2B102 Danfoss 11/

18 Calculation of pressure loss on the valve for required flow (continued) 3. Enter the required flow for the branch. 4. Answer will appear in the Results window. 18 VUE2B102 Danfoss 11/2008 HEC

19 Working with Projects PFM 4000 Multisource includes a built-in module for project balancing calculations comprised of one horizontal and a maximum of 100 vertical branches. The calculation assumes that the pressure input of the project is constant and that the project is devoid of negative feedback hydraulic elements (for instance differential pressure regulators within branches or thermostatic valves). Basic Project Schematic HEC VUE2B102 Danfoss 11/

20 Starting with projects 1. Select Projects in the main menu. 2. The last project to be opened in the Project window. 3. Press New 4. We recommend you use the Projects folder on the SD Card in case of system failure. 20 VUE2B102 Danfoss 11/2008 HEC

21 Creating new project 1. Select the Project tab and click on Menu, New followed by Edit buttons. 2. Fill in underlined fields including Initial presetting. Uncheck Common Valve box if it is not present in the project 3. Example: Note it is not necessary to fill in the Input pressure at this point. It will be possible to measure it using the Project/Measure function, as described in the next section. The calculated Common valve presetting can be viewed in the Presetting Window at the end of project balancing. 4. Select the Branch tab and click on Menu, Add button. HEC VUE2B102 Danfoss 11/

22 Creating new project (continued) 5. Fill in the Branch name, Valve Manufacturer and Type, Requested flow and the Initial presetting. The other fields will be filled automatically during branch measuring or after the balancing calculation. 6. Example: Similarly to the Input pressure, it will be possible to measure the Initial flow and Close pressure using the Menu/Measure function. 7. Add the rest of the branches included in the project following the above instructions. Note that the order of branches in the project must correspond to the distance of each branch from the input pressure source. 8. The correct order of branches in the project can be set by moving selected up or down in the project structure. 22 VUE2B102 Danfoss 11/2008 HEC

23 Preparing for project balancing measuring 1. Prior to measuring, the Initial presetting has to be set on all balancing valves within the project including the common valve. When re-balancing an existing or newly designed project, it is most effective to enter the actual presetting of balancing valves within. 2. Connect PFM 4000 Multisource sensor to the input pressure. Select the Project tab followed by the Menu/Measure button. 3. The value measured will be automatically filled in the corresponding field. 4. Connect PFM 4000 Multisource sensor to the balancing valve at any branch and select the appropriate branch in the Branch tab. It is necessary to measure both the Flow through the valve with Initial presetting of the balancing valve and the Available pressure in the branch with the balancing valve being closed. HEC VUE2B102 Danfoss 11/

24 Preparing for project balancing measuring (continued) 5. Click on the Menu/Measure button and select Before project balancing type of measuring. 6. PFM 4000 Multisource will automatically choose the correct valve and presetting according to the branch selected. The Initial flow measured will be saved along with the rest of the branch data. 7. Close the balancing valve in the branch prior to measuring the available pressure in the branch. The value measured will again be saved along with branch data. 8. The project is ready for balancing after the Initial flow and Available pressure for each branch of the project has been measured. 24 VUE2B102 Danfoss 11/2008 HEC

25 Balancing of basic project 1. Return to the Project tab and click on the Menu/Balancing button. 2. Select Basic project balancing. The balancing progress is depicted by a bar graph. 3. In order to minimise power losses in the project, PFM 4000 Multisource starts balancing with a 3kPa pressure drop on the balancing valve in the last branch. Next, the nonbalanced branches are optimised. If for any branch a higher pressure drop is required on the balancing valve, the computing will be restarted with an increased pressure drop in the last branch. The balancing stops when the minimum number of branches is not balanced. 4. The result of balancing appears in the State field in the Start Balancing window. HEC VUE2B102 Danfoss 11/

26 Project with Central Pressure Input We often come across systems with a central pressure input with a distribution of the medium to either side of the input. It is possible to balance such project by virtually dividing it into two separate projects with unidirectional branch distribution. The two projects are measured and balanced individually and subsequently drawn together using the Bind Projects command as follows. 26 VUE2B102 Danfoss 11/2008 HEC

27 Balancing calculation of a project with central pressure input - procedure 1. Create two projects - Left Side and Right Side as depicted above. 2. Close the Right Side project by a stop valve. 3. Measure the Left Side project. 4. Close the Left Side project by a stop valve. 6. Switch to Project tab and click on the Menu/Balancing button. 5. Open and measure the Right Side project. 7. Click on Middle power project balancing button. 8. Open one side of the middle powered project for instance the left side. HEC VUE2B102 Danfoss 11/

28 Balancing calculation of a project with central pressure input procedure (continued) 9. Open the second side of the middle powered project right side. 10. PFM 4000 Multisource will balance the two projects separately. Next, it will rebalance the side of the project that requires higher pressure after the common valve. Finally, it will correct the KV of the common valve for both of the projects. The balancing progress can be monitored on the PDA screen. 28 VUE2B102 Danfoss 11/2008 HEC

29 Measuring actual flow 1. Click on Branch tab and select branch to measured. Click on Menu/Measure button. 2. Select After project balancing and click OK. 3. The flow value measured will be entered under the Flow parameter of the selected branch. HEC VUE2B102 Danfoss 11/

30 Replacement of sintered filters When PFM 4000 Multisource starts reacting slowly to changes in pressure or when after powering up the pressure displayed exceeds 5 kpa, it is necessary to change sintered filters as shown in the picture below. If there is no improvement, please return to the manufacturer for servicing. 30 VUE2B102 Danfoss 11/2008 HEC

31 Using of Routers You can use relay wireless mode for long distance measuring or measuring in project with heavy radio waves propagation. Router is designed in PFM4000 casing with external high performance thin-rod antenna. Router needs only switching power On and OFF and its state is indicated by LED diode. 1. Select Menu, Change sensor to use routers 2. Check use routers, fill in radio address if it is necessary. Radio address is S/N written on the bottom side. Searching of pressure units do not run via routers. Make sure that you are close to pressure unit during searching. HEC VUE2B102 Danfoss 11/

32 Scheme of Using Routers Using of router for single sensor. Using of two routers for single sensor. Using of two sensors with routers (proportional method). 32 VUE2B102 Danfoss 11/2008 HEC

33 Operations after PDA clean reset - Radio card installation When it is possible to perform clean reset of PDA it si necessary install radio card drivers. Do not insert radio card to PDA before installation of drivers!!!! Install drivers from PDA File Explorer folder SD Card/Drivers in three steps: Run 01_elSerial.ARM.CAB. Tab on Install to continue installation. Driver was successfully installed. Run 2_netcf.all.wce4. ARMV4.CA20B. HEC VUE2B102 Danfoss 11/

34 Operations after PDA clean reset - Radio card installation (continued) Tab on Install to continue installation. Tab on OK to finish installation. Run 03_OpenNETCF.SCF. ppv3.arvw4.cab. Tab on Install to continue installation. 34 VUE2B102 Danfoss 11/2008 HEC

35 Operations after PDA clean reset - Radio card installation (continued) After installation of drivers insert radiocard into PDA. If New modem detected Windows is shown, tab on Dismiss. Now you can find new item elcomid in Program group. elcomid software display COM port used by radiocard. Select this COM port in Connection item from main menu PFM4000. HEC VUE2B102 Danfoss 11/

36 Operations after PDA clean reset - PFM4000 Multisource program installation 1. Run SD_Card/Setup /PFM4000.cab from PDA File Explorer. 2. Tap on PFM4000.cab icon to install. 3. Choose the Device location for Danfoss/PFM4000 program. 4. You will use procedure described in previous column also for upgrade of PFM4000 program. 36 VUE2B102 Danfoss 11/2008 HEC

37 Technical specifications Main pressure unit Pressure range kpa ~ 0-10 bar kpa ~ 0-20 bar Max. static pressure or 20 bar Max. over pressure 1200 kpa ~ 12 bar 2200 kpa ~ 22 bar Reliability, linearity and hysteresis error % of range Temperature error % of range Static pressure effect... ± 200 Pa Medium temperature - 5 to 90 C (at end of connection tubes) Ambient temperature to 50 C Storage temperature to 70 C Temperature probe... Pt 100 digital Temperature measuring range to 120 C Temperature measuring error... ± 1 C Power Li lon battery 3.6 V 950 mah (for Nokia 6230 mobile phone) Operating time Max. 120 hours Charging time... 7 hours Interface RF wireless band 868 MHz Communication speed bps RF transmitter power 25 mw Radio range (open air) Up to 30 m Wireless routers MHz band, 500 mw Number of routers... max. 3 Radio range with 3 routers (open air), Multisource m Number of records Max Dimensions (w x h x d) x 19 x 25 mm Weight g Cover... IP 65 Calibration validity months HEC VUE2B102 Danfoss 11/

Operation Manual PFM Flex 2

Operation Manual PFM Flex 2 Operation Manual PFM Flex 2 The new and unique PFM FLEX Concept comprises 4 different Instruments for Flow and Pressure measurements. From the simplest Flex 1 to the most advanced Flex 4. The differences

More information

Z CAM K1 Pro. User Manual (Draft) v1.0

Z CAM K1 Pro. User Manual (Draft) v1.0 Z CAM K1 Pro User Manual (Draft) v1.0 1. INTRODUCTION Camera Introduction Display Information LED Indicator Status Green: When the camera is turned on with SD card in the slot. Red: When the camera is

More information

TR-101 User Manual. Ver 1.14

TR-101 User Manual. Ver 1.14 User Manual Ver 1.14 Table of Contents 1. Introduction... 3 2. Features... 3 3. Specification... 4 4. Start-up... 5 4.1 Accessories... 5 4.2 Charging the battery... 6 4.3 Install SIM card... 6 5. Hardware

More information

WIRELESS RECEIVER WRM-TS. Rev. 1.0c

WIRELESS RECEIVER WRM-TS. Rev. 1.0c WIRELESS RECEIVER WRM-TS U S E R M A N U A L Rev. 1.0c TABLE OF CONTENTS 1. General information 3 2. Technical parameters 4 3. Normal mode of operation 4 4. Command reference 5 4.1. Command get 6 4.2.

More information

Multifunction instrument AMI 310

Multifunction instrument AMI 310 Multifunction instrument AMI 310 Table of contents 1 Presentation...6 1.1 Instrument description...6 1.2 Remove battery...7 1.3 Insert SD card...7 2 Connections of the AMI310...8 2.1 Main features...8

More information

Portable low-pressure controller Model CPC2000

Portable low-pressure controller Model CPC2000 Calibration technology Portable low-pressure controller Model CPC2000 WIKA data sheet CT 27.51 Applications Mobile calibration of low-pressure measuring instruments Supply of very low positive or negative

More information

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs MobilTherm 2ad GSM temperature alarm module with auxiliay inputs and relay outputs The MobilTherm-2ad is a GSM temperature and remote signaling module, designed for GSM based remote control, remote signal.

More information

NewVission Portable Interactive Pad

NewVission Portable Interactive Pad NewVission Portable Interactive Pad U-15WF User Guide Contents I. General Information... 1 1. Overview... 1 2. Pen Tablet Functions... 1 3. System Requirements... 1 4. Installing the Driver Software on

More information

GSDR Basic set up using QRP2000. Modes using third party software will be covered in another tutorial. Remember you must download two files, the

GSDR Basic set up using QRP2000. Modes using third party software will be covered in another tutorial. Remember you must download two files, the GSDR Basic set up using QRP2000. Modes using third party software will be covered in another tutorial. Remember you must download two files, the install and the latest update. Extract both folders and

More information

1. Presentation. 1.1 Instrument description. 1.2 Keys description

1. Presentation. 1.1 Instrument description. 1.2 Keys description TM 210 Thermometer Table of contents 1.Presentation...5 1.1. Instrument description...5 1.2. Keys description...5 1.3. Remove battery...6 2.Connections of the TM210...7 2.1. Main features...7 2.2. Connections...7

More information

Application. Automation Studio is now compatible with Windows 8.

Application. Automation Studio is now compatible with Windows 8. March 2013 Application Automation Studio is now compatible with Windows 8. 2 Quick Access to Translations A new Translation Manager quick access button was added to the toolbar. It is also possible to

More information

SAV-09 Semi-automatic Falling Rod Viscometer Set up and operating Instructions

SAV-09 Semi-automatic Falling Rod Viscometer Set up and operating Instructions SAV-09 Semi-automatic Falling Rod Viscometer Set up and operating Instructions Table of Contents 1.0 Overview 2.0 Components 3.0 Viscometer Stand set-up and Installation 4.0 Elapse Timer Set - up and Installation

More information

IntelliSense HC1000. User Manual

IntelliSense HC1000. User Manual IntelliSense HC1000 User Manual Tablet of contents 1. What is TPMS... 3 2. Safety Instructions.... 4 3. IntelliSense HC1000... 5 4. Bluetooth configuration.... 6 4.1 Windows... 6 4.2 Android... 7 5. IntelliSense

More information

telstra.com/wifi visit a telstra store or partner GETTING TO KNOW YOUR TELSTRA Wi-Fi 4G ADVANCED PRO X

telstra.com/wifi visit a telstra store or partner GETTING TO KNOW YOUR TELSTRA Wi-Fi 4G ADVANCED PRO X telstra.com/wifi 13 2200 visit a telstra store or partner GETTING TO KNOW YOUR TELSTRA Wi-Fi 4G ADVANCED PRO X LET S GET THIS SHOW ON THE ROAD WHAT S INSIDE Your Telstra Wi-Fi 4G Advanced Pro X has been

More information

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM PROPORTIONAL and NON-PROPORTIONAL TOGGLE SWITCH RADIO REMOTE CONTROL SYSTEM MODEL FHSTP/DSSTP SERIES FHST/DSST SYSTEM DESCRIPTION The DSST Wireless Control

More information

LT30 GETTING STARTED GUIDE GPS/GIS HANDHELD CONTROLLER

LT30 GETTING STARTED GUIDE GPS/GIS HANDHELD CONTROLLER LT30 GETTING STARTED GUIDE GPS/GIS HANDHELD CONTROLLER Copyright Copyright 2009-2012 CHC Shanghai HuaCe Navigation Technology Ltd. All rights reserved. The CHC are trademark of Shanghai Huace Navigation

More information

HAND-HELD GAS ANALYSER

HAND-HELD GAS ANALYSER HAND-HELD GAS ANALYSER Manual Version: 1.0 11/2010 Index 1. Introduction...3 2. Construction of the GA-12 gas analyser...4 2.1. Electric connections...4 2.2. Gas channel...5 2.3. Supply...5 3. Maintenance

More information

AWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD

AWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD AWA6223S Sound Level Calibrator Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD Notes 1. Please read the instruction carefully before using the instruments for the first time. 2. The calibrator

More information

DATA LOGGER GEOLOGGER G8 PLUS

DATA LOGGER GEOLOGGER G8 PLUS A D V A C E D DATA LOGGER GEOLOGGER G8 PLUS I N S T CONFIGURATION & WIRING OF PERIPHERALS R U C T I O N M A N U A L 1 CONTENTS DESCRIPTION PAGE Main components 3 G8 Module Connections 4 G8 Module Connections

More information

EziNav G3 User Manual

EziNav G3 User Manual EziNav G3 User Manual 4.3 Touchscreen GPS with Bluetooth About this User Manual Congratulations on your purchase of your Kogan EziNav G3 GPS. This user manual provides information regarding the various

More information

Product description for ED1600 generic Sigfox Module

Product description for ED1600 generic Sigfox Module Product description for ED1600 generic Sigfox Module The ED1600 Sigfox Module is mainly developed for container tracking purposes. To avoid the development of many different types of modules and just as

More information

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , , Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI 840080, 840081, 840082 840083, 840085 Manometers 840080, 840081, 840082, 840083, 840085 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the

More information

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM-6650.02 1 Instruction Manual DM-6650.02 TABLE OF CONTENTS I.0 INTRODUCTION 3 1.1 General Description... 3 1.2 Specifications... 3 1.3

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Exploration Drive Aberdeen Science and Energy Park Aberdeen AB23 8HZ Contact: Mr Graham Robertson Tel: +44(0)1224 708500 Fax: +44(0)1224 772

More information

Quick Reference Guide VT30 TPM SERVICE TOOL VT30. Version: MJC-1409-US2. QRG3814d

Quick Reference Guide VT30 TPM SERVICE TOOL VT30. Version: MJC-1409-US2. QRG3814d Quick Reference Guide VT30 TPM SERVICE TOOL VT30 Version: MJC-1409-US2 QRG3814d TABLE OF CONTENTS Section A - GENERAL DESCRIPTION A1 - Front face page 3/10 A2 - Power Supply page 4/10 A3 - USB connector

More information

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm P in mw v in m/s page 1 of 12 The SF-586b Insertion Thermal Mass Flow Meter,

More information

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3

More information

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway MAKING MODERN LIVING POSSIBLE Manual Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway www.danfoss.com 2 FRCC.ES.011.A1.02 CONTENTS Introduction... 4 General Description...4

More information

Philips GoGear audio video player SA065104K SA065104S SA065108K SA065108S. Quick start guide

Philips GoGear audio video player SA065104K SA065104S SA065108K SA065108S. Quick start guide Philips GoGear audio video player SA065104K SA065104S SA065108K SA065108S Quick start guide Need help? Please visit www.philips.com/welcome where you can access to a full set of supporting materials such

More information

Thank you for your purchase USER MANUAL

Thank you for your purchase USER MANUAL Thank you for your purchase USER MANUAL MANUAL ICONS Warning: situations involving injury risk of the user or other persons. Attention: situations, when damage of device or other equipment may be caused.

More information

FOTEMP1 Handheld. FOTEMP1 Handheld is a compact, user-friendly, and easy to operate instrument for many fields of application, e.g.

FOTEMP1 Handheld. FOTEMP1 Handheld is a compact, user-friendly, and easy to operate instrument for many fields of application, e.g. FOTEMP1 Handheld is a mobile 1 channel-optical fiber thermometer used for measuring temperature in an environment with high electromagnetic interference, or with the presence of high power microwave fields.

More information

MEDIUM-PRESSURE-CALIBRATOR

MEDIUM-PRESSURE-CALIBRATOR MEDIUM-PRESSURE-CALIBRATOR STANDARD- AND FULL-VERSION RANGE SERIAL-NR. PROGRAM-VERSION DATE KELLER INCLUDED IN DELIVERY: MEDIUM PRESSURE CALIBRATOR STANDARD-VERSION INCLUDED IN DELIVERY: MEDIUM PRESSURE

More information

Battery operated recorders. Built-in battery operated GSM modem Text message alerts Data collecting to Comet database software and Comet cloud

Battery operated recorders. Built-in battery operated GSM modem Text message alerts Data collecting to Comet database software and Comet cloud Battery operated recorders Built-in battery operated GSM modem Text message alerts Data collecting to Comet database software and Comet cloud Battery operated GSM modem Mobile Dataloggers Two buttons keypad

More information

Renewable Energy. Getting Started With the LEGO Energy Meter

Renewable Energy. Getting Started With the LEGO Energy Meter Renewable Energy Getting Started With the LEGO Energy Meter de LEGO Group. 2010 The LEGO Group. 1 Table of Contents 1. Energy Meter Overview... 3 2. Attaching the Energy Storage... 3 3. Charging and discharging

More information

1. Presentation. 1.1 Instrument description. 1.2 Keys description

1. Presentation. 1.1 Instrument description. 1.2 Keys description TM 210 Thermometer Table of contents 1.Presentation...5 1.1. Instrument description...5 1.2. Keys description...5 1.3. Remove battery...6 2.Connections of the TM210...7 2.1. Main features...7 2.2. Connections...7

More information

IR Wireless Interpretation System

IR Wireless Interpretation System IR Wireless Interpretation System GONSIN TC-904/906/908/912 infrared interpretation system is designed to offer audio distribution for 4, 6, 8 or 12 channels using the advanced infrared transmission technology.

More information

N.B.: Please read these instructions carefully before using the device and keep them for future reference!

N.B.: Please read these instructions carefully before using the device and keep them for future reference! N.B.: Please read these instructions carefully before using the device and keep them for future reference! 1. CONTENTS Your package contains: - 1 Smeezu Smartwatch - 1 USB cable to connect the device to

More information

LEGO Energy Meter. How to Get Started

LEGO Energy Meter. How to Get Started LEGO Energy Meter How to Get Started The Energy Meter consists of two parts: the LEGO and LEGO. The fits onto the bottom of the. To install the, simply slide it down onto the. To remove the, press the

More information

TA-SCOPE. Instruments Balancing instrument

TA-SCOPE. Instruments Balancing instrument TA-SCOPE Instruments Balancing instrument IMI TA / Measuring tools / TA-SCOPE TA-SCOPE TA-SCOPE is a tough, effective balancing instrument for measuring and documenting of differential pressure, flow,

More information

E5331 FAQs Q2: Hardware specifications of E5331: Q4: What information displayed on E5331 s OLED screen?... 5

E5331 FAQs Q2: Hardware specifications of E5331: Q4: What information displayed on E5331 s OLED screen?... 5 E5331 FAQs... 2 Q1: Main Features of E5331:... 2 Q2: Hardware specifications of E5331:... 2 Q3: Keys, Interface of E5331... 5 Q4: What information displayed on E5331 s OLED screen?... 5 Q5: The AutoPlay

More information

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,

More information

NannyCam V24. Instructions 1 For Use

NannyCam V24. Instructions 1 For Use NannyCam V24 Instructions 1 For Use Package Contents: Parent Unit (with display) + power adapter Baby Unit (camera) + power adapter Instructions for Use Baby Unit Overview: 1. Light Sensor 2. Camera Lens

More information

User Manual. Cobia Flex R/F. English - v2014.3a

User Manual. Cobia Flex R/F. English - v2014.3a User Manual Cobia Flex R/F English - v2014.3a NOTICE RTI Electronics AB reserves the right to make changes to the Cobia Flex R/F and the information in this user manual without prior notice. RTI Electronics

More information

Copyright ANRITSU. All rights reserved.

Copyright ANRITSU. All rights reserved. General Caution --------------- Please use a USB Memory Stick for firmware updates. If there is a firmware update question, please contact Anritsu service support at https://techsupport.anritsu.com, and

More information

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Certification Mark GB Installation and User Instructions GB Index Index 3-14 Product Specification 3 Installation

More information

USER MANUAL MBAR EX By JETI model s.r.o

USER MANUAL MBAR EX By JETI model s.r.o USER MANUAL MBAR EX By JETI model s.r.o. 14. 11. 2014 CONTENTS 1. INTRODUCTION...3 2. MAIN FEATURES...3 3. PLACEMENT OF MBAR EX SENSOR...3 4. CONNECTING THE MBAR EX SENSOR...4 5. SETTING VIA JETIBOX...5

More information

DI-5C. Prisma INSTRUMENT USER MANUAL

DI-5C. Prisma INSTRUMENT USER MANUAL DI-5C Prisma INSTRUMENT USER MANUAL INDEX 1. Instrument overview 2. How to use the instrument 2:1 Description 2:2 Display 2:3 On/Off & push buttons 2:4 Settings Set date / time Change number of digits

More information

M-BUS-2. User Manual LORAWAN CONVERTER.

M-BUS-2. User Manual LORAWAN CONVERTER. LORAWAN CONVERTER M-BUS-2 User Manual M-BUS-2 converter is used for reading of values from metering instruments via M-BUS interface and further transmitting of this data to the LoRaWAN network. M-BUS-2

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

Wireless Open-Source Open Controlled Command and Control System WOCCS Design Project. User Manual

Wireless Open-Source Open Controlled Command and Control System WOCCS Design Project. User Manual MSD - 2011 Rochester Institute of Technology Wireless Open-Source Open Controlled Command and Control System WOCCS Design Project User Manual Revision 1 P11204 Systems Level User Manual WOCCS User Manual

More information

Installation Guide DEVIlink CC Central Controller

Installation Guide DEVIlink CC Central Controller DEVIlink CC Central Controller www.devi.com Table of Contents 1 Introduction.................................... 4 2 Guidelines for installation....................... 5 3 Installation plan.................................

More information

Short Operating Instruction for Professional Miniature Audio and Video Recorder mavr H.264x4

Short Operating Instruction for Professional Miniature Audio and Video Recorder mavr H.264x4 Short Operating Instruction for Professional Miniature Audio and Video Recorder mavr H.264x4 Overlook Audio and Video Recorder MAVR-H264x4 is intended for professional recording of video data with sound

More information

ibidi PumpControl Instruction Manual Version 1.5.0

ibidi PumpControl Instruction Manual Version 1.5.0 ibidi PumpControl Instruction Manual Version 1.5.0 II ibidi GmbH 2011, version 1.5.0, revision 2, 2011-10-26, Andreas Rainer Table of contents 1 General Information... 1 1.1 System Requirements... 1 1.2

More information

LevelOne BLH-1000 Bluetooth Headset User s Manual

LevelOne BLH-1000 Bluetooth Headset User s Manual LevelOne BLH-1000 Bluetooth Headset User s Manual - 1 - Introduction Introduction to Bluetooth Wireless Technology Bluetooth is a short- range wireless communication technology. It allows wireless connections

More information

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com Model R5005 True RMS Industrial Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 4 Features... 5 Specifications...5-6 Instrument Description...7-8 Operating Instructions...9-13

More information

Installation and Operating Instructions for Air-Bubbler Differential Pressure Aquagauge Tank Level Telemetry System.

Installation and Operating Instructions for Air-Bubbler Differential Pressure Aquagauge Tank Level Telemetry System. Installation and Operating Instructions for Air-Bubbler Differential Pressure Aquagauge Tank Level Telemetry System. Liquid depth is measured using a pressure sensor at the top of a column of air extending

More information

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE WE CONNECT REAL WORLD TO THE STRUCTURAL MONITORING SENSORS WIRELESS INTERFACE SOFTWARE CLOUD Rev.10 del 3/10/017 Redatto da: R&D e MKT Approvato da: CEO Smart structural WIRELESS Interface NI00 devices

More information

Balancing valve PN 16 and PN 25 DN

Balancing valve PN 16 and PN 25 DN STAF, STAF-SG Balancing valve PN and PN DN 0-00 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE A flanged, cast iron (STAF) and ductile iron (STAF-SG) balancing

More information

MANUAL PORTABLE TDR METER. Part Number: FOM/mts. Ver. 1.41

MANUAL PORTABLE TDR METER. Part Number: FOM/mts. Ver. 1.41 MANUAL PORTABLE TDR METER Part Number: FOM/mts Ver. 1.41 Designed and Manufactured by: E-TEST Institute of Agrophysics Polish Academy of Sciences Lublin, Poland Distributed in Australia by: Edaphic Scientific

More information

FROG-4000TM Quick Start Guide

FROG-4000TM Quick Start Guide FROG-4000TM Quick Start Guide 1 Precautions DO NOT invert the instrument with the sparge bottle attached. DO NOT transport or store the instrument with liquid in the sparge bottle. DO NOT handle or carry

More information

Programmable Room Thermostat. User Guide UFHPROGB & UFHPROGRFB

Programmable Room Thermostat. User Guide UFHPROGB & UFHPROGRFB Programmable Room Thermostat User Guide UFHPROGB & UFHPROGRFB Overview The Programmable Room Thermostats Range (UFHPROGB & UFHPROGRFB) provides time and temperature control for a space of up to 40m 2.

More information

BTH033-KMA26 Bluetooth stereo headset User s manual

BTH033-KMA26 Bluetooth stereo headset User s manual BTH033-KMA26 Bluetooth stereo headset User s manual Contents Brief introduction........1 1. Bluetooth wireless communication technology....1 2. About BTH033-KMA26...1 Before use..2 1. Overview... 2 2.

More information

INSTRUCTION MANUAL DRAWINGS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

INSTRUCTION MANUAL DRAWINGS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OK OAP 3040-8 INSTRUCTION MANUAL DRAWINGS AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 1 Table of Contents Features... 3 Precautions... 3 Warning... 3 Buttons & Controls... 4 Main menu... 5

More information

Precision hand-held pressure indicator Model CPH6400

Precision hand-held pressure indicator Model CPH6400 Calibration technology Precision hand-held pressure indicator Model CPH6400 WIKA data sheet CT 14.01 Applications Calibration service companies and service industry Measurement and control laboratories

More information

1080P AVALANCHE SERIES SNOW GOGGLES

1080P AVALANCHE SERIES SNOW GOGGLES 1080P AVALANCHE SERIES SNOW GOGGLES Getting Started: Congratulations on your purchase of Cyclops Gear 1080 Avalanche Series Snow Goggles. You will be able to shoot high-definition video and take high quality

More information

GeoExplorer 6000 Series Quick Start Guide

GeoExplorer 6000 Series Quick Start Guide GeoExplorer 6000 Series Quick Start Guide Four simple steps to get started: This guide provides an overview of the important features and instructions for how to set up and operate your Trimble GeoExplorer

More information

H A N D O U T : T R O U B L E S H O O T I N G L A P T O P S

H A N D O U T : T R O U B L E S H O O T I N G L A P T O P S H A N D O U T : T R O U B L E S H O O T I N G L A P T O P S Revision Date: 5/9/2013 Time 1.0 Hour K EY POIN T S Connecting an external monitor to your laptop may require pressing a sequence of keys in

More information

GETTING TO KNOW YOUR TELSTRA PRE-PAID 4GX WI-FI PLUS

GETTING TO KNOW YOUR TELSTRA PRE-PAID 4GX WI-FI PLUS telstra.com/ppmbb 125 8880 or from a non-telstra phone 13 2200 and say pre-paid visit a telstra store or partner GETTING TO KNOW YOUR TELSTRA PRE-PAID 4GX WI-FI PLUS LET S GET THIS SHOW ON THE ROAD WHAT

More information

GASWorkS 10.0 Example. Town DXF. Summary. Steps. 1) Import The DXF File

GASWorkS 10.0 Example. Town DXF. Summary. Steps. 1) Import The DXF File Summary In this example, a model will be created from an existing DXF file. The piping drawn in the DXF file will be imported to create the model schematic. The DXF file will also be used as a background

More information

DVK User Manual. Scope. Related Melexis Products. Introduction

DVK User Manual. Scope. Related Melexis Products. Introduction Scope The MLX90129 from Melexis is a sensor IC with an integrated 13.56 MHz high frequency (HF) interface that allows sensor data to be read with a HF radio frequency identification (RFID) reader. The

More information

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax: OPERATION MANUAL /ORP 300 (Cat. No. 0580212) MICROCOMPUTER BASED /ORP/ Temperature CONTROLLER 625 East Bunker CT, Vernon Hills, IL 60061-1844 Phone: 800-32-4340, Fax: 847-247-2929 E-mail: info@coleparmer.com,

More information

USER MANUAL. Turbine Blade Tip-to-Casing Cold Clearance. Wireless Measurement Kit CMS Model

USER MANUAL. Turbine Blade Tip-to-Casing Cold Clearance. Wireless Measurement Kit CMS Model USER MANUAL Turbine Blade Tip-to-Casing Cold Clearance Wireless Measurement Kit Model CMS-3400 PHILTEC 1 www.philtec.com Fiber Optic Sensors for the Measurement of Distance, Displacement and Vibration

More information

TOC F1 Operations Manual

TOC F1 Operations Manual TOC F1 Operations Manual - 1 - General Description The TOC F1 is a single channel wireless lens control system. The system can be used on most broadcast or cinema lenses. The TOC F1 includes a hand held

More information

Lex Talus Corporation

Lex Talus Corporation Lex Talus Corporation 109 East 17th Street, Suite 80 Cheyenne, WY 82001 Tel: (775) 434.0420 To: Subject: Nomad Purchaser FAQ The first thing you must do with your new Nomad is to calibrate the battery.

More information

SHORT INSTRUCTIONS ULTRASONIC TESTING DEVICE

SHORT INSTRUCTIONS ULTRASONIC TESTING DEVICE Ultrasound occurs during a wide range of processes. Using the associated sensors these signals Different apps are used in order to perform recordings, evaluations and documentation for the following servicing

More information

3 Channel Datalogging Thermometer

3 Channel Datalogging Thermometer USER MANUAL 3 Channel Datalogging Thermometer Model SD200 Introduction Congratulations on your purchase of the Extech SD200 3-Channel Temperature Datalogger. This meter displays and stores temperature

More information

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL ISF-1DF SERIES-E www.insize.com ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL V0 Attention Description Regardless of whether the unit is ON or OFF, Don t exceed the capacity of the gauge. At 110%

More information

User's Guide. 3 Channel Datalogging Thermometer Model SD200

User's Guide. 3 Channel Datalogging Thermometer Model SD200 User's Guide 3 Channel Datalogging Thermometer Model SD200 Introduction Congratulations on your purchase of the Extech SD200 3-Channel Temperature Datalogger. This meter displays and stores temperature

More information

Version 1.4 June 2018

Version 1.4 June 2018 1 Version 1.4 June 2018 Table Of Contents 1. Introduction 3 2. Unpacking the Instrument 4 2.1. Standard Accessories 2.2. Optional Accessories 3. Specifications 4 4. Installation 5 4.1. Quick 4-20 ma Start

More information

EBI 25 Wireless Data Logger System

EBI 25 Wireless Data Logger System 62 EBI 25 Wireless Data Logger System The EBI 25 system for wireless monitoring of temperature, humidity and other measurements assures that perishable goods are produced and stored at the right conditions

More information

RMS Mini Wireless Data Logger

RMS Mini Wireless Data Logger 2018 ROTRONIC AG Bassersdorf Switzerland Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Mini Data Logger... 5 1.4 Power Supply... 5 1.5 Measured Parameters...

More information

Wireless TV Chin Guard Headphone TX-99

Wireless TV Chin Guard Headphone TX-99 Technaxx * User Manual Wireless TV Chin Guard Headphone TX-99 With this comfortable and good-fitting headphone you can enjoy listening to television or music at your preferred volume without disturbing

More information

Carkuda (VTG500X) User Manual

Carkuda (VTG500X) User Manual Carkuda (VTG500X) User Manual Contents Carkuda Concepts Quick Start Installing Carkuda Mirror Using Carkuda Mirror Using Carkuda Smartphone App Technical Specifications Packing List FAQs Revision History

More information

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan SPECIFICATIONS HAND HELD PARTICLE COUNTER KC-52 3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan No. 10017-3E 18-04 Printed in Japan Outline The hand held particle counter KC-52 is designed to

More information

Motion Sensor 2 with temperature sensor

Motion Sensor 2 with temperature sensor Neo Coolcam Motion Sensor 2 with temperature sensor SKU: NEOEMS02Z Quickstart This is a Multilevel Sensor for Europe. To run this device please insert fresh 1 * CR123A batteries. Please make sure the internal

More information

MobilControl MC 4000 OWNER S MANUAL

MobilControl MC 4000 OWNER S MANUAL MobilControl MC 4000 Hand Held Service instrument with data logger for pressure, min / max & differential pressure, temperature, flow / rpm and hydraulic horsepower OWNER S MANUAL 20 7 TERMINALS 7.1 Plugs

More information

Installation and operation manual ReciFlow Gas

Installation and operation manual ReciFlow Gas Installation and operation manual ReciFlow Gas 1 1. Measurement principle... 3 2. Installation... 5 3. Operation... 7 4. Electrical interfaces... 11 5. Communication protocol... 14 6. Software update and

More information

TSM1 Infrared Data Logger

TSM1 Infrared Data Logger The TSM1 Temperature Sensor Meter is a stand-alone logging instruments for the measurement of leaf, canopy, soil or surface temperature. The TSM can support up to 5 Apogee Instruments or Everest Interscience

More information

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Service Bulletin SB685 Date: 8/18/2017 Subject: TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Units: All TriPac EVOLUTION Summary: This bulletin updates and

More information

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

ARA FTS Flow Calibrator. Operation Manual August 1, 2016 ARA FTS Flow Calibrator Operation Manual August 1, 2016 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 1 2. GETTING STARTED 1 2.1. Navigation 1 2.2. Charge Battery 1 2.3. Set Date and Time 2 2.4. Plug-In

More information

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater revision 03 2012 RCF-230CTD Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater RCF-230CTD is a room controller intended

More information

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at User Manual Heavy Duty Differential Pressure Manometer Model SDL720 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech SDL720 Pressure

More information

4-Channel Thermometer / Datalogger

4-Channel Thermometer / Datalogger User's Guide 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This

More information

12-Channel Thermocouple Datalogger

12-Channel Thermocouple Datalogger User Manual 12-Channel Thermocouple Datalogger Model TM500 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech TM500 Thermometer,

More information

INSTALLATION MANUAL for the Application ihc-mirf

INSTALLATION MANUAL for the Application ihc-mirf INSTALLATION MANUAL for the Application ihc-mirf Contents Introduction 3 Installing the application on a mobile phone 3 Settings 4 Control 12 Introduction The applications ihc-mirf (for mobile phones with

More information

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL CATALOG NUMBERS 600-1000, 600-1010 and 600-1020 91100-00, 91100-10 and 91100-20 PROPRIETARY Information contained in this manual is proprietary to COLE-PARMER

More information

Simulator Maintenance: SimMan3G & SimMan Essential

Simulator Maintenance: SimMan3G & SimMan Essential Simulator Maintenance: SimMan3G & SimMan Essential Introductions, Laerdal Field Service, America s, Laerdal Technical Support, America s Basic Manikin Trouble shooting ASSEMBLY & DISASSEMBLY Basic Manikin

More information

CoverTitle. PinPoint X. Quick Start Guide for AT&T Rev 3.0C

CoverTitle. PinPoint X. Quick Start Guide for AT&T Rev 3.0C PinPoint X Quick Start Guide for AT&T CoverTitle 20070914 Rev 3.0C Activating your PinPoint X on AT&T Installing the SIM Configuring the APN Hardware Installation Indicator Lights Optional: Setting up

More information

HD 1080 Pro Black Box Security Wi-Fi Camera

HD 1080 Pro Black Box Security Wi-Fi Camera HD 1080 Pro Black Box Security Wi-Fi Camera User Manual Version: Oct, 2017 Content Quick Guide...P2 Overview...P3 Packing List...P3 Product structure...p4 Camera Part Setting...P5 Camera name and password

More information

QUICK GUIDE for 4 modules. Installation

QUICK GUIDE for 4 modules. Installation QUICK GUIDE for 4 modules Installation 1. Prepare a SIM card so that the PIN code is 1234 or is deactivated. Mount the card in the unit. The unit has now 1234 as password or runs without a password. The

More information