- Verity Craig
- 5 years ago
- Views:
Transcription
1 Kirby NK Heavy Commercial Industrial Unit Cooler Natural fluids: Glycol water MT 20kW LT 16kW 110kW 68kW
2 Product Overview > The NK range is designed for industrial refrigeration, storage or deep-freezing applications > The NK version H (high efficiency) is ideal for the storage of packed products > Economical choice, wide range of options for specific Heavy Duty industrial applications. Range offers fin spacing distances: 4, 6, 9 mm (6, 4 or 3 FPI) Description Casing The casing is made of pre-painted, galvanised steel offering a high resistance to corrosion and impact damage An internal aluminium drain pan limits the effects of condensation under the main drain pan during the defrost process The NK unit coolers are delivered in mounting position in reinforced crates Ventilation 2 fan types are used for the NK range: Ø 630 mm 4/6 pole (1,500/1,000 rpm) - Ø 800 mm 6/8 pole (1,000/750 rpm) Selection of a unit cooler with various fan number/diameter combinations offering the dimensional and air throw characteristics best adapted to the size of the cold room Selections should be confirmed by your Heatcraft Technical Specialist ( ) Coil The finned coils of the NK range are designed with aluminium fins spaced at 4, 6, or 9 mm, crimped onto copper tubes High-efficiency H type fins for an economical solution. This type of fin is particularly suitable for the storage of packed products. The reduced size of the heat-exchanger also enables fast defrosting The galvanised steel side panels and drain pan are hinge mounted for easy access, maintenance and cleaning. Nomenclature Data NKH(1) 3x6(2) D(3) B2(4) R(5) (1) H High-efficiency fin (2) Number of fans x Ø: 6 Ø 630 mm - 8 Ø 800 mm (3) Motor connection: D Delta (4) Module (5) Fin spacing: R 4 mm - L/C 6 mm - S 9 mm Defrost NKH... C, NKH... S The shielded electric heating elements are inserted in sleeves located in the finned coil, 2 or 3 heating elements are placed under the intermediate drain pan This facility enables homogenous heat distribution for fast and efficient defrosting Total gas defrost (HGT) available as optional extra NKH... R, NKH... L Light electric defrost (E1U) and low temperature electric defrost (ELU) models available as optional extra A water defrost (DAE) option is available for room temperature equal to or greater than +4 C. In this case the unit cooler depth is increased by 40 mm Maximum water flow-rate with NK: 1 fan 5 m3/h. - 2 fans 10 m3/h 3 fans 15 m3/h. - 4 fans 20 m3/h Options Ventilation VPA (Kit): Air pressure shell also allowing the connection of a textile duct Coil BXT (Factory): Blygold Polual XT coil protection (local) WCO (Factory): Glycol water, coolant (please contact us for details) Refrigerant Factor 2 Defrost E1U (Factory): Light electric defrost ELU (Factory): defrost (coil + drain pan) HGT (Factory): Hot gas (coil and drain pan) RVU (Factory): Shell defrost heaters DAE (Factory): Water defrost Options As Listed Are Available On Request - For Assistance Please Contact Your Local Heatcraft Branch Glycol options available - Selections should be confirmed by your Heatcraft Technical Specialist ( ) Refrigerant R134a R407F Medium Temperature Low Temperature
3 Dimensional Data Ø 630 mm A Vent. D A 25 Ø A D mini Ø 11/ Vent. D A H 542 NK... 1x6... NK... 2x6... D mini Ø 11/2 NK... 3x6... H NK... 4x6... Ø 800 mm NK... 1x NK... 2x8... NK... 3x8... NK... 4x Ø 19 3
4 Performance Data Medium Temperature Condition (-4 C SST & 6KTD) NKH...R H High-efficiency fin 4 mm NKH... R NKH1X6DB3R NKH1X6DC2R NKH2X6DB2R NKH3X6DB1R NKH2X8DC1R NKH2X8DC2R Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 1 x x x x x x 800 Air flow m 3 /h (3) standard m (3) with VPA option m (3) Acoustic Lp 4m db(a) (4) defrost light E1U (2) defrost heavy ELU (2) Ω Nb W A Ω Nb W A Net weight kg Inlet Ø 1 1/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 Outlet Ø 1 5/8 2 1/8 2 1/8 2 1/8 2 5/8 2 5/8 NKH... R NKH3X6DB2R NKH4X6DB1R NKH3X8DC1R NKH4X6DB2R NKH4X6DB3R NKH3X8DC2R NKH4X8DC2R Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 3 x x x x x x x 800 Air flow m 3 /h (3) standard with VPA option m (3) m (3) Acoustic Lp 4m db(a) (4) defrost light E1U (2) defrost heavy ELU (2) Nb W A Nb W A Net weight kg Inlet Ø 2x 1 3/8 2x 1 5/8 1 5/8 2x 1 3/8 2x 1 5/8 2x 1 5/8 2x 1 5/8 Outlet Ø 2x 2 1/8 2x 2 1/8 2 5/8 2x 2 1/8 2x 2 1/8 2x 2 1/8 2x 2 5/8 * Ø 630 mm : 400 : 1900 W max - 3,20 A max - Y 1200 W max - 1,95 A max - per fan * Ø 800 mm : 400 : 2000 W max - 4,00 A max - Y 1250 W max - 2,30 A max - per fan (1) Residual air speed: 0.25 m/s, in compliance with standard. (2) defrost options - light or heavy defrost input. (3) For motor connection in star (Y) instead of delta (D), refer to the correction factors. (4) Average sound pressure level in db(a) measured at 4m, at fan height, in direct line of sight on a reflective surface, given for information only. 4
5 Performance Data Medium Temperature Condition (-4 C SST & 6KTD) NKH...L H High-efficiency fin 6 mm NKH... L NKH1X6DB3L NKH1X8DC2L NKH2X6DB1L NKH2X6DB3L NKH2X8DC1L NKH2X8DC2L Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 1 x x x x x x 800 Air flow m 3 /h (3) standard m (3) with VPA option m (3) Acoustic Lp 4m db(a) (4) defrost light E1U (2) defrost heavy ELU (2) Ω Nb W A Ω Nb W A Net weight kg Inlet Ø 1 1/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 Outlet Ø 1 5/8 2 1/8 2 1/8 2 1/8 2 1/8 2 5/8 NKH... L NKH3X6DB2L NKH3X6DB3L NKH4X6DB2L NKH3X8DC2L NKH4X6DB3L NKH4X8DC2L Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 3 x x x x x x 800 Air flow m 3 /h (3) standard with VPA option m (3) m (3) Acoustic Lp 4m db(a) (4) defrost light E1U (2) defrost heavy ELU (2) Nb W A Nb W A Net weight kg Inlet Ø 2x 1 3/8 1 5/8 2x 1 3/8 2x 1 5/8 2x 1 5/8 2x 1 5/8 Outlet Ø 2x 2 1/8 2 5/8 2x 2 1/8 2x 2 1/8 2x 2 1/8 2x 2 1/8 * Ø 630 mm : 400 : 1900 W max - 3,20 A max - Y 1200 W max - 1,95 A max - per fan * Ø 800 mm : 400 : 2000 W max - 4,00 A max - Y 1250 W max - 2,30 A max - per fan (1) Residual air speed: 0.25 m/s, in compliance with standard. (2) defrost options - light or heavy defrost input. (3) For motor connection in star (Y) instead of delta (D), refer to the correction factors. (4) Average sound pressure level in db(a) measured at 4m, at fan height, in direct line of sight on a reflective surface, given for information only. 5
6 Performance Data Low Temperature Condition (-24 C SST & 6KTD) NKH...C H High-efficiency fin 6 mm NKH... C NKH1X6DB3C NKH1X8DC2C NKH2X6DB1C NKH2X6DB2C NKH2X6DB3C Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 1 x x x x x 630 Air flow m 3 /h (3) standard with m (3) VPA option m (3) Acoustic Lp 4m db(a) (4) Nb W defrost A Net weight kg Inlet Ø 1 1/8 1 3/8 1 3/8 1 5/8 1 5/8 Outlet Ø 2 1/8 2 1/8 2 1/8 2 5/8 2 5/8 NKH... C NKH2X8DC1C NKH3X6DB2C NKH3X6DB3C NKH3X8DC2C NKH4X6DB3C Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 2 x x x x x 630 Air flow m 3 /h (3) standard with m (3) VPA option m (3) Acoustic Lp 4m db(a) (4) Nb W defrost A Net weight kg Inlet Ø 1 5/8 2 x 1 3/8 2 x 1 5/8 2 x 1 5/8 2 x 1 5/8 Outlet Ø 2 5/8 2 x 2 1/8 2 x 2 1/8 2 x 2 5/8 2 x 2 5/8 * Ø 630 mm : 400 : 1900 W max - 3,20 A max - Y 1200 W max - 1,95 A max - per fan * Ø 800 mm : 400 : 2000 W max - 4,00 A max - Y 1250 W max - 2,30 A max - per fan (1) Residual air speed: 0.25 m/s, in compliance with standard. (3) For motor connection in star (Y) instead of delta (D), refer to the correction factors. (4) Average sound pressure level in db(a) measured at 4m, at fan height, in direct line of sight on a reflective surface, given for information only. 6
7 Performance Data Low Temperature Condition (-24 C SST & 6KTD) NKH...S H High-efficiency fin 9 mm NKH... S NKH1X6DB3S NKH2X6DB1S NKH1X8DC2S NKH2X8DC1S NKH2X6DB3S NKH2X8DC2S Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 1 x x x x x x 800 Air flow m 3 /h (3) standard m (3) SA44 45 with VPA option m (3) Acoustic Lp 4m db(a) (4) defrost Ω Nb W A Net weight kg Inlet Ø 1 1/8 1 3/8 1 3/8 1 5/8 1 3/8 1 5/8 Outlet Ø 2 1/8 2 1/8 2 1/8 2 5/8 2 5/8 2 5/8 NKH... S NKH3X6DB2S NKH3X8DC1S NKH3X6DB3S NKH3X8DC2S NKH4X6DB3S NKH4X8DC2S Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 3 x x x x x x 800 Air flow m 3 /h (3) standard with VPA option m (3) m (3) Acoustic Lp 4m db(a) (4) defrost Nb W A Net weight kg Inlet Ø 2x 1 1/8 1 5/8 2x 1 3/8 2x 1 5/8 2x 1 5/8 2x 1 5/8 Outlet Ø 2x 2 1/8 2 5/8 2x 2 1/8 2x 2 1/8 2x 2 5/8 2x 2 5/8 * Ø 630 mm : 400 : 1900 W max - 3,20 A max - Y 1200 W max - 1,95 A max - per fan * Ø 800 mm : 400 : 2000 W max - 4,00 A max - Y 1250 W max - 2,30 A max - per fan (1) Residual air speed: 0.25 m/s, in compliance with standard. (2) defrost options. (3) For motor connection in star (Y) instead of delta (D), refer to the correction factors. (4) Average sound pressure level in db(a) measured at 4m, at fan height, in direct line of sight on a reflective surface, given for information only. 7
8 australia heatcraft.com.au new zealand heatcraft.co.nz Australia Head Office Heatcraft Australia Pty Ltd, 286 Horsley Road, Milperra NSW 2214 Locked Bag 63, Wetherill Park NSW 1851 (+61) New Zealand Head Office Heatcraft New Zealand Pty Ltd 12 George Bourke Drive, Mt Wellington PO Box Penrose, Auckland (+64) All trade marks and registered trade marks are the property of their respective owners and are used for identification purposes only. Copyright 2015 Heatcraft Australia Pty Limited. Heatcraft Australia continually strive to improve products and processes. We reserve the right to modify product features without notice. Information is correct at time of printing.
NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.
AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >
More information09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD
Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,
More informationChiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw
Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote
More informationAIR COOLED CONDENSERS
AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)
More informationkyalfa V- VDD/VDD6 General Contents
General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationMOLLIER DIAGRAM CAN BE IMPROVED!
MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.
More informationKLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION
PRODUCT DATA & INSTALLATION Bulletin K30-KLP-PDI-16 Part # 1087150 PRODUCT SUPPORT web: k-rp.com/klp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KLP Low Profile Evaporators Air, Electric, Hot
More informationHIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationAIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS
PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial
More informationALFRESCO SERIES RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW. Specifications and Detailed Product Overview
RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW Specifications and Detailed Product Overview WEATHER RATED TV ENCLOSURES Designed and engineered in Australia, to suit our tough environmental conditions,
More informationWEIGHING PLATFORMS. Trade, commerce and industry. Product Numbers 2816, 2817, 2818, 2822
WEIGHING PLATFORMS Product Numbers 2816, 2817, 2818, 2822 Trade, coerce and industry > Weighing platforms for floor scales > Sturdy, flat design > With stainless steel, painted or hot-dip galvanised >
More informationAIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS
RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.
More informationU-Match Series DC Inverter Service Manual PRODUCT
PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870
More informationFPS SERIES Super Slim Ceiling Mount Air Handling Units
About Multistack 19, Multistack is well-known in the international air conditioning industry by its invention of modular chiller. Today, Multistack has grown into an international refrigeration & air conditioning
More informationMin. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208
More informationYour Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant
Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,
More informationglide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA
99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and
More informationStandard Frame Axial Fans
Quick reference guide Standard Frame Axial Fans 2007 Edition about Axair Fans UK Application knowledge : 20 years experience in air movement; from fume handling to refrigeration; from small electronic
More informationMotivair MLC-SC Air-Cooled Scroll Chillers Tons
INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced
More informationHigh Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)
High Voltage Induction Motors -MII Series New High Efficiency Design for High Capacity Applications Up to,0 kw (,0 HP) MII Series: Combining over 00 years of experience with innovative new technology makes
More informationBrasch Washdown Unit Heaters
Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt
More information1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil
More information1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,
More informationFOX-50 Heat Flow Meter
FOX-50 Heat Flow Meter Site Preparation Guide Revision A Issued June 2016 Page 1 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...
More informationBDD/BDD6 - Double Fan Row
Product description. kybdd/bdd6 - Double Fan Row ky Product description Application The Alfa Laval dry coolers can be used in refrigeration, air conditioning equipment and in Industrial ooling (cooling
More informationPT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone
PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 0 Jl. Malibu Raya, Cengkareng Jakarta Barat 70 Indonesia Phone + 4 4 www.climanusa.com Marketing features prominent presence on the world
More informationSTANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request
PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer
More informationDUCTED SPLIT SYSTEMS With Scroll compressors
DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping
More information4. TARGETED COOLING & AIRFLOW MANAGEMENT
4.4. TARGETED COOLING & TARGETED COOLING & AIRFLOW MANAGEMENT 4.AIRFLOW TARGETED MANAGEMENTCO 76 79 80 81 82 :: targeted cooling & airflow management 4. TARGETED COOLING & AIRFLOW MANAGEMENT 4.1 - Side
More informationSpecification and Design Catalog. Waterside Economizer
Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................
More informationSmoothAir Modular Precision Cooling
TM SmoothAir Modular Precision Cooling ODM/OEM/Customization+ Specialist Support+ Modular Precision Cooling for Smart, Reliable and Green MDC Solution Why Choose Us Products Support Customization Products
More informationNOW AVAILABLE AT IP66 RATING. Fast Fit. 3 phase distribution boards. clipsal.com. Designed for easy installation and fast wiring
NOW AVAILABLE AT IP66 RATING Fast Fit 3 phase distribution boards clipsal.com Designed for easy installation and fast wiring We ve opened our doors to commercial SERIES 4consumer switchboards The Clipsal
More informationVRF. Technical Data Book. DVM S Eco 8, 9 HP
VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature
More informationHIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz
More informationIT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw
IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable
More information42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h
2/V Fan oil Unit Air Flow: 0~0m 3 /h arrier hina arrier orporation is a subsidiary of the United Technologies orp. (UT), which ranks the 10th in Fortune Top 00 in and has its operations in aerospace and
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationBox Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Systemair Box Fans
Box Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Systemair Box Fans KVD, KVB, KPD & KPB Systemair Group Systemair (Sweden) Systemair (Spain)
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationDEPENDABLE BY DESIGN EASE OF USE PERFORMANCE SERVICEABILITY DURABILITY
FOR VENDED LAUNDRY DEPENDABLE BY DESIGN The Maytag Multi-Load Washer is built to provide the performance and durability your business needs. PERFORMANCE Experience optimal wash performance with a consistent
More informationCHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51
CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Unit Page CHA/IK/WP - CHA/CLK 8 - CHA/ML/ST - CHA/ML/ST 9 8-9 CHA/ML/ST 8-P 0-P 0 - FROM, KW TO KW. CHA/IK/WP
More informationModels: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists
More information1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series
More informationDaikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013
Replacement Parts List No. 700017400 Revision G 12/2013 Daikin McQuay Incremental Comfort System PKEI, PKES, PKHS 007, 009, 012, 014 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787
More informationFilter Fan Unit LIGHT
Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual
More informationIBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling
IBM Symposium 2008 Data Center Cooling EC Systems for HVAC architecture and Direct air Cabinet Cooling Presented by David J. Spofford Product Manager IT/Telecomm 1 Agenda Data Center trends for IT and
More informationTechnical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC
Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air
More informationSemi-hermetic Air-cooled Condensing Units
Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable
More informationChilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers
Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens
More informationAuraCool Economizer System
Page 1 Due to manufacturer's policy of continuous product improvement, the manufacturer reserves the right to make changes without notice. Drawings in this submittal are representations of the equipment
More informationCTC Low Temperature Process Chillers
INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in
More informationSlim duct (AMTTTFNLDEH ) Indoor units
Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,
More informationGTH. Rectangular double deflection grille QUICK FACTS
Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative
More informationAir Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C
Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-C Indoor Unit FTX-C TALE OF CONTENTS FTX-C 1 Features............................................................. 2 2 Specifications.......................................................
More informationCooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS
Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data
More informationEcoflair Air Economizers
Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your
More informationMLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough
More informationCHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS
CHAPTER WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS Unit Page CWW/K 8-9 CWW/K 8-P 0-P 0 - CWW/K 8 0 - MEA/K - MEA/K 8-P 0-P - RCA/K
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change
More informationMPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class
More informationApplication Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners
Page 1 of 184 Software for the simulation of refrigeration equipment and air conditioners Index Software for the simulation of refrigeration equipment and air conditioners... 1 : application description
More informationDCC Commercial. Submittal Data Form Tons Packaged Air Conditioners
DCC Commercial Submittal Data Form 15-25 Tons Packaged Air Conditioners 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h Job Name
More informationAquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors
Aquaflair Air-cooled chillers and free-cooling chillers with double screw compressors BREC & BREF 350-1200kW 380V/3ph/60Hz - 460V/3ph/60Hz The all-in-one solution for your business need Combining cutting-edge
More informationWALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA181, WA241 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists
More informationDDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear
I TECHNICAL SPECIFICATIONS ROAD BUILDING DDDM 45 (40-60 TPH) DOUBLE DRUM ASPHALT PLANT - DDDM 50 (60-90 TPH) DDDM 60 (90-120 TPH) COLD AGGREGATE FEEDER Stationary four bin cold aggregate feeder unit is
More informationMK SERIES CROSS FLOW COOLING TOWER
The Ultimate Cooling Machine MK SERIES CROSS FLOW COOLING TOWER CERTIFIED PERFORMANCE DURABLE ENERGY & SPACE SAVING MODEL DEFINITION FOR MK2348E-2BI MK 2348 E 2 B I CROSS FLOW TYPE BOX SIZE MOTOR SIZE
More informationThermal Design and Management of Servers
White Paper Thermal Design and Management of Servers Thermal Design and Management of Servers P.1 Overview With the exponential growth of knowledge development, data needs to be stored, processed and secured
More informationThermal management. Thermal management
Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately
More informationFALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread
More informationOutside Plant. Compact Multi-Function Joint - CMJ. Features and Benefits. Prysmian Part Number: CMJ-E-X-XXXX-X-Y-X. Kit Contents. Closure Part Number
Compact Multi-Function Joint - CMJ Prysmian Part Number: CMJ-E-X-XXXX-X-Y-X The Compact Multi Function Joint (CMJ) is for jointing optical fibre cables. The joint is ideal for use as a Cable Chamber Joint,
More informationSERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2)
DUCT TYPE AIR CONDITIONER (Cool) TYPE ADH4400G DH44ZA(A2) INDOOR UNIT IDH4400A DH44ZA(A2) OUTDOOR UNIT UDH4400G DH44ZAX SERVICE Manual AIR CONDITIONER CONTENTS. Product Specifications 2. Installation 3.
More informationLiebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers
Liebert HPC Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC: Freecooling Solutions for Increased Data Center Efficiency and PUE of 1.1 Freecooling data center chillers
More informationDCG Commercial. Submittal Data Form
DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons
More informationKNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).
PRODUCT NEWS Products News: New HC-A16KNX PAGE 1 / 8 Summary 1. This advanced product news introduces the new product HC-A16KNX. 2. The details are indicated in the description. Description 1. Applicable
More informationCabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan
DCH Series Submittal Data Form 7½ - 12½ Ton Packaged Heat Pump Up to 11.5 EER & 3.4 COP Cooling Capacity: 90,000 140,000 BTU/h Heating Capacity: 90,000 142,000 BTU/h Job Name Purchaser Order No. Engineer
More informationType Differential pressure transducer
Homepage > Products > Control systems > Control system EASYLAB - LABCONTROL > Sensor systems > Type Differenzdrucktransmitter Type Differential pressure transducer FOR THE DIFFERENTIAL PRESSURE RECORDING
More informationIntroducing the Heat Wheel to the Data Center
Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure Specialist KyotoCooling International Critical Facilities Round Table 1 A New Free Cooling Technique
More informationStrip Till. Ultimate in Strip Till Versatility & Performance. The. Toll Free:
Strip Till The Ultimate in Strip Till Versatility & Performance Toll Free: 1-800-537-7370 www.remlingermfg.com The Original Remlinger Precision Strip Till (PST) row unit was farmer inspired and tested.
More informationCTXA-AS/AT/AW, FTXA-AS/AT/AW
Split Air Conditioning Technical Data CTXA-AS/AT/AW, FTXA-AS/AT/AW > CTXAA2V1BS > CTXAA2V1BT > CTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT
More informationAir Handling Units. With Intelligence
Air Handling Units With Intelligence Production facility in India Services on your doorstep STULZ is a global company with headquarters in Hamburg, Germany. 19 Subsidiaries, 9 Production sites and Sales
More informationVIREO Ceiling with ALX
Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient
More informationFEATURES AND BENEFITS. Installation and operation. Controller
DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.
More informationAquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.
Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling
More informationDatasheet.
Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk
More informationCooling of. Offering a safe & reliable way to cool semiconductor equipment & applications SOLUTIONS GUIDE
Cooling of Power Electronics Offering a safe & reliable way to cool semiconductor equipment & applications SOLUTIONS GUIDE Bring us your toughest thermal application challenge Mersen will help you maximize
More informationSlim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL
E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical
More informationVariable Air Management System. Installation Guide V1.1
Variable Air Management System Installation Guide V1.1 Installation Guide Contents 1 - OVERVIEW 2 - INSTALLATION PROCEDURE 3 - TOUCH SCREEN SETUP 4 - TROUBLE SHOOTING 1 2 3 4 Installation Guide V1.1 1
More informationACFD12-T ACFD12-B. Technical Data
TM ACFD12-T ACFD12-B Technical Data Contents Overview.................................................1 Scalable Solution for Critical Environments....................2 Standard Features.........................................5
More informationTEC Unit Conditioner Controller
Document No. 540-1026 TEC Unit Conditioner Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2040 and 2041 2050 through 2054 Product Description
More informationSINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU
SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)
More informationBlue e+ chillers with the principle
Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide
More informationProduct Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres
Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how
More informationan EnerSys Company Shelter Cooling Systems
an EnerSys Company Shelter Cooling Systems Overview Managing the internal temperature within specialist Equipment Shelters is critical when it comes to protecting your sensitive equipment. With over 20
More informationCPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A
CPH Series 7½- to 12½-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Heat Pump with R-410A Standard
More informationCHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw
IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING
More informationAquaflair. BREC/F and BCEC/F kw
Aquaflair Air-cooled chillers and free-cooling chillers with screw or oil-free centrifugal compressors equipped with adiabatic system BREC/F and BCEC/F 350-1350 kw Dualism for evolution: the combination
More information