Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water

Size: px
Start display at page:

Download "Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water"

Transcription

1 Kirby NK Heavy Commercial Industrial Unit Cooler Natural fluids: Glycol water MT 20kW LT 16kW 110kW 68kW

2 Product Overview > The NK range is designed for industrial refrigeration, storage or deep-freezing applications > The NK version H (high efficiency) is ideal for the storage of packed products > Economical choice, wide range of options for specific Heavy Duty industrial applications. Range offers fin spacing distances: 4, 6, 9 mm (6, 4 or 3 FPI) Description Casing The casing is made of pre-painted, galvanised steel offering a high resistance to corrosion and impact damage An internal aluminium drain pan limits the effects of condensation under the main drain pan during the defrost process The NK unit coolers are delivered in mounting position in reinforced crates Ventilation 2 fan types are used for the NK range: Ø 630 mm 4/6 pole (1,500/1,000 rpm) - Ø 800 mm 6/8 pole (1,000/750 rpm) Selection of a unit cooler with various fan number/diameter combinations offering the dimensional and air throw characteristics best adapted to the size of the cold room Selections should be confirmed by your Heatcraft Technical Specialist ( ) Coil The finned coils of the NK range are designed with aluminium fins spaced at 4, 6, or 9 mm, crimped onto copper tubes High-efficiency H type fins for an economical solution. This type of fin is particularly suitable for the storage of packed products. The reduced size of the heat-exchanger also enables fast defrosting The galvanised steel side panels and drain pan are hinge mounted for easy access, maintenance and cleaning. Nomenclature Data NKH(1) 3x6(2) D(3) B2(4) R(5) (1) H High-efficiency fin (2) Number of fans x Ø: 6 Ø 630 mm - 8 Ø 800 mm (3) Motor connection: D Delta (4) Module (5) Fin spacing: R 4 mm - L/C 6 mm - S 9 mm Defrost NKH... C, NKH... S The shielded electric heating elements are inserted in sleeves located in the finned coil, 2 or 3 heating elements are placed under the intermediate drain pan This facility enables homogenous heat distribution for fast and efficient defrosting Total gas defrost (HGT) available as optional extra NKH... R, NKH... L Light electric defrost (E1U) and low temperature electric defrost (ELU) models available as optional extra A water defrost (DAE) option is available for room temperature equal to or greater than +4 C. In this case the unit cooler depth is increased by 40 mm Maximum water flow-rate with NK: 1 fan 5 m3/h. - 2 fans 10 m3/h 3 fans 15 m3/h. - 4 fans 20 m3/h Options Ventilation VPA (Kit): Air pressure shell also allowing the connection of a textile duct Coil BXT (Factory): Blygold Polual XT coil protection (local) WCO (Factory): Glycol water, coolant (please contact us for details) Refrigerant Factor 2 Defrost E1U (Factory): Light electric defrost ELU (Factory): defrost (coil + drain pan) HGT (Factory): Hot gas (coil and drain pan) RVU (Factory): Shell defrost heaters DAE (Factory): Water defrost Options As Listed Are Available On Request - For Assistance Please Contact Your Local Heatcraft Branch Glycol options available - Selections should be confirmed by your Heatcraft Technical Specialist ( ) Refrigerant R134a R407F Medium Temperature Low Temperature

3 Dimensional Data Ø 630 mm A Vent. D A 25 Ø A D mini Ø 11/ Vent. D A H 542 NK... 1x6... NK... 2x6... D mini Ø 11/2 NK... 3x6... H NK... 4x6... Ø 800 mm NK... 1x NK... 2x8... NK... 3x8... NK... 4x Ø 19 3

4 Performance Data Medium Temperature Condition (-4 C SST & 6KTD) NKH...R H High-efficiency fin 4 mm NKH... R NKH1X6DB3R NKH1X6DC2R NKH2X6DB2R NKH3X6DB1R NKH2X8DC1R NKH2X8DC2R Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 1 x x x x x x 800 Air flow m 3 /h (3) standard m (3) with VPA option m (3) Acoustic Lp 4m db(a) (4) defrost light E1U (2) defrost heavy ELU (2) Ω Nb W A Ω Nb W A Net weight kg Inlet Ø 1 1/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 Outlet Ø 1 5/8 2 1/8 2 1/8 2 1/8 2 5/8 2 5/8 NKH... R NKH3X6DB2R NKH4X6DB1R NKH3X8DC1R NKH4X6DB2R NKH4X6DB3R NKH3X8DC2R NKH4X8DC2R Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 3 x x x x x x x 800 Air flow m 3 /h (3) standard with VPA option m (3) m (3) Acoustic Lp 4m db(a) (4) defrost light E1U (2) defrost heavy ELU (2) Nb W A Nb W A Net weight kg Inlet Ø 2x 1 3/8 2x 1 5/8 1 5/8 2x 1 3/8 2x 1 5/8 2x 1 5/8 2x 1 5/8 Outlet Ø 2x 2 1/8 2x 2 1/8 2 5/8 2x 2 1/8 2x 2 1/8 2x 2 1/8 2x 2 5/8 * Ø 630 mm : 400 : 1900 W max - 3,20 A max - Y 1200 W max - 1,95 A max - per fan * Ø 800 mm : 400 : 2000 W max - 4,00 A max - Y 1250 W max - 2,30 A max - per fan (1) Residual air speed: 0.25 m/s, in compliance with standard. (2) defrost options - light or heavy defrost input. (3) For motor connection in star (Y) instead of delta (D), refer to the correction factors. (4) Average sound pressure level in db(a) measured at 4m, at fan height, in direct line of sight on a reflective surface, given for information only. 4

5 Performance Data Medium Temperature Condition (-4 C SST & 6KTD) NKH...L H High-efficiency fin 6 mm NKH... L NKH1X6DB3L NKH1X8DC2L NKH2X6DB1L NKH2X6DB3L NKH2X8DC1L NKH2X8DC2L Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 1 x x x x x x 800 Air flow m 3 /h (3) standard m (3) with VPA option m (3) Acoustic Lp 4m db(a) (4) defrost light E1U (2) defrost heavy ELU (2) Ω Nb W A Ω Nb W A Net weight kg Inlet Ø 1 1/8 1 3/8 1 3/8 1 5/8 1 5/8 1 5/8 Outlet Ø 1 5/8 2 1/8 2 1/8 2 1/8 2 1/8 2 5/8 NKH... L NKH3X6DB2L NKH3X6DB3L NKH4X6DB2L NKH3X8DC2L NKH4X6DB3L NKH4X8DC2L Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 3 x x x x x x 800 Air flow m 3 /h (3) standard with VPA option m (3) m (3) Acoustic Lp 4m db(a) (4) defrost light E1U (2) defrost heavy ELU (2) Nb W A Nb W A Net weight kg Inlet Ø 2x 1 3/8 1 5/8 2x 1 3/8 2x 1 5/8 2x 1 5/8 2x 1 5/8 Outlet Ø 2x 2 1/8 2 5/8 2x 2 1/8 2x 2 1/8 2x 2 1/8 2x 2 1/8 * Ø 630 mm : 400 : 1900 W max - 3,20 A max - Y 1200 W max - 1,95 A max - per fan * Ø 800 mm : 400 : 2000 W max - 4,00 A max - Y 1250 W max - 2,30 A max - per fan (1) Residual air speed: 0.25 m/s, in compliance with standard. (2) defrost options - light or heavy defrost input. (3) For motor connection in star (Y) instead of delta (D), refer to the correction factors. (4) Average sound pressure level in db(a) measured at 4m, at fan height, in direct line of sight on a reflective surface, given for information only. 5

6 Performance Data Low Temperature Condition (-24 C SST & 6KTD) NKH...C H High-efficiency fin 6 mm NKH... C NKH1X6DB3C NKH1X8DC2C NKH2X6DB1C NKH2X6DB2C NKH2X6DB3C Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 1 x x x x x 630 Air flow m 3 /h (3) standard with m (3) VPA option m (3) Acoustic Lp 4m db(a) (4) Nb W defrost A Net weight kg Inlet Ø 1 1/8 1 3/8 1 3/8 1 5/8 1 5/8 Outlet Ø 2 1/8 2 1/8 2 1/8 2 5/8 2 5/8 NKH... C NKH2X8DC1C NKH3X6DB2C NKH3X6DB3C NKH3X8DC2C NKH4X6DB3C Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 2 x x x x x 630 Air flow m 3 /h (3) standard with m (3) VPA option m (3) Acoustic Lp 4m db(a) (4) Nb W defrost A Net weight kg Inlet Ø 1 5/8 2 x 1 3/8 2 x 1 5/8 2 x 1 5/8 2 x 1 5/8 Outlet Ø 2 5/8 2 x 2 1/8 2 x 2 1/8 2 x 2 5/8 2 x 2 5/8 * Ø 630 mm : 400 : 1900 W max - 3,20 A max - Y 1200 W max - 1,95 A max - per fan * Ø 800 mm : 400 : 2000 W max - 4,00 A max - Y 1250 W max - 2,30 A max - per fan (1) Residual air speed: 0.25 m/s, in compliance with standard. (3) For motor connection in star (Y) instead of delta (D), refer to the correction factors. (4) Average sound pressure level in db(a) measured at 4m, at fan height, in direct line of sight on a reflective surface, given for information only. 6

7 Performance Data Low Temperature Condition (-24 C SST & 6KTD) NKH...S H High-efficiency fin 9 mm NKH... S NKH1X6DB3S NKH2X6DB1S NKH1X8DC2S NKH2X8DC1S NKH2X6DB3S NKH2X8DC2S Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 1 x x x x x x 800 Air flow m 3 /h (3) standard m (3) SA44 45 with VPA option m (3) Acoustic Lp 4m db(a) (4) defrost Ω Nb W A Net weight kg Inlet Ø 1 1/8 1 3/8 1 3/8 1 5/8 1 3/8 1 5/8 Outlet Ø 2 1/8 2 1/8 2 1/8 2 5/8 2 5/8 2 5/8 NKH... S NKH3X6DB2S NKH3X8DC1S NKH3X6DB3S NKH3X8DC2S NKH4X6DB3S NKH4X8DC2S Capacity (kw) in Australian condition () kw (3) Surface m Circuit volume dm Fan High Speed* Nb x Ø mm 3 x x x x x x 800 Air flow m 3 /h (3) standard with VPA option m (3) m (3) Acoustic Lp 4m db(a) (4) defrost Nb W A Net weight kg Inlet Ø 2x 1 1/8 1 5/8 2x 1 3/8 2x 1 5/8 2x 1 5/8 2x 1 5/8 Outlet Ø 2x 2 1/8 2 5/8 2x 2 1/8 2x 2 1/8 2x 2 5/8 2x 2 5/8 * Ø 630 mm : 400 : 1900 W max - 3,20 A max - Y 1200 W max - 1,95 A max - per fan * Ø 800 mm : 400 : 2000 W max - 4,00 A max - Y 1250 W max - 2,30 A max - per fan (1) Residual air speed: 0.25 m/s, in compliance with standard. (2) defrost options. (3) For motor connection in star (Y) instead of delta (D), refer to the correction factors. (4) Average sound pressure level in db(a) measured at 4m, at fan height, in direct line of sight on a reflective surface, given for information only. 7

8 australia heatcraft.com.au new zealand heatcraft.co.nz Australia Head Office Heatcraft Australia Pty Ltd, 286 Horsley Road, Milperra NSW 2214 Locked Bag 63, Wetherill Park NSW 1851 (+61) New Zealand Head Office Heatcraft New Zealand Pty Ltd 12 George Bourke Drive, Mt Wellington PO Box Penrose, Auckland (+64) All trade marks and registered trade marks are the property of their respective owners and are used for identification purposes only. Copyright 2015 Heatcraft Australia Pty Limited. Heatcraft Australia continually strive to improve products and processes. We reserve the right to modify product features without notice. Information is correct at time of printing.

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement. AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >

More information

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)

More information

kyalfa V- VDD/VDD6 General Contents

kyalfa V- VDD/VDD6 General Contents General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

MOLLIER DIAGRAM CAN BE IMPROVED!

MOLLIER DIAGRAM CAN BE IMPROVED! MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.

More information

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin K30-KLP-PDI-16 Part # 1087150 PRODUCT SUPPORT web: k-rp.com/klp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KLP Low Profile Evaporators Air, Electric, Hot

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial

More information

ALFRESCO SERIES RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW. Specifications and Detailed Product Overview

ALFRESCO SERIES RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW. Specifications and Detailed Product Overview RESIDENTIAL WEATHER RATED TV ENCLOSURES PRODUCT OVERVIEW Specifications and Detailed Product Overview WEATHER RATED TV ENCLOSURES Designed and engineered in Australia, to suit our tough environmental conditions,

More information

WEIGHING PLATFORMS. Trade, commerce and industry. Product Numbers 2816, 2817, 2818, 2822

WEIGHING PLATFORMS. Trade, commerce and industry. Product Numbers 2816, 2817, 2818, 2822 WEIGHING PLATFORMS Product Numbers 2816, 2817, 2818, 2822 Trade, coerce and industry > Weighing platforms for floor scales > Sturdy, flat design > With stainless steel, painted or hot-dip galvanised >

More information

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

FPS SERIES Super Slim Ceiling Mount Air Handling Units

FPS SERIES Super Slim Ceiling Mount Air Handling Units About Multistack 19, Multistack is well-known in the international air conditioning industry by its invention of modular chiller. Today, Multistack has grown into an international refrigeration & air conditioning

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA 99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and

More information

Standard Frame Axial Fans

Standard Frame Axial Fans Quick reference guide Standard Frame Axial Fans 2007 Edition about Axair Fans UK Application knowledge : 20 years experience in air movement; from fume handling to refrigeration; from small electronic

More information

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Motivair MLC-SC Air-Cooled Scroll Chillers Tons INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced

More information

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP) High Voltage Induction Motors -MII Series New High Efficiency Design for High Capacity Applications Up to,0 kw (,0 HP) MII Series: Combining over 00 years of experience with innovative new technology makes

More information

Brasch Washdown Unit Heaters

Brasch Washdown Unit Heaters Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt

More information

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS CX35 Upflow - Cased - R-40A PRODUCT SPECIFICATIONS Bulletin No. 0668 November 06 Supersedes September 05.5 to 5 Tons MODEL NUMBER IDENTIFICATION C X 35-36 A - 6 F Unit Type C = Indoor Coil

More information

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal

More information

Liquid Cooling Package LCP Cooling Systems

Liquid Cooling Package LCP Cooling Systems Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,

More information

FOX-50 Heat Flow Meter

FOX-50 Heat Flow Meter FOX-50 Heat Flow Meter Site Preparation Guide Revision A Issued June 2016 Page 1 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...

More information

BDD/BDD6 - Double Fan Row

BDD/BDD6 - Double Fan Row Product description. kybdd/bdd6 - Double Fan Row ky Product description Application The Alfa Laval dry coolers can be used in refrigeration, air conditioning equipment and in Industrial ooling (cooling

More information

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 0 Jl. Malibu Raya, Cengkareng Jakarta Barat 70 Indonesia Phone + 4 4 www.climanusa.com Marketing features prominent presence on the world

More information

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

4. TARGETED COOLING & AIRFLOW MANAGEMENT

4. TARGETED COOLING & AIRFLOW MANAGEMENT 4.4. TARGETED COOLING & TARGETED COOLING & AIRFLOW MANAGEMENT 4.AIRFLOW TARGETED MANAGEMENTCO 76 79 80 81 82 :: targeted cooling & airflow management 4. TARGETED COOLING & AIRFLOW MANAGEMENT 4.1 - Side

More information

Specification and Design Catalog. Waterside Economizer

Specification and Design Catalog. Waterside Economizer Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................

More information

SmoothAir Modular Precision Cooling

SmoothAir Modular Precision Cooling TM SmoothAir Modular Precision Cooling ODM/OEM/Customization+ Specialist Support+ Modular Precision Cooling for Smart, Reliable and Green MDC Solution Why Choose Us Products Support Customization Products

More information

NOW AVAILABLE AT IP66 RATING. Fast Fit. 3 phase distribution boards. clipsal.com. Designed for easy installation and fast wiring

NOW AVAILABLE AT IP66 RATING. Fast Fit. 3 phase distribution boards. clipsal.com. Designed for easy installation and fast wiring NOW AVAILABLE AT IP66 RATING Fast Fit 3 phase distribution boards clipsal.com Designed for easy installation and fast wiring We ve opened our doors to commercial SERIES 4consumer switchboards The Clipsal

More information

VRF. Technical Data Book. DVM S Eco 8, 9 HP

VRF. Technical Data Book. DVM S Eco 8, 9 HP VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature

More information

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h

42C/V. Fan Coil Unit Air Flow: 340~2040m 3 /h 2/V Fan oil Unit Air Flow: 0~0m 3 /h arrier hina arrier orporation is a subsidiary of the United Technologies orp. (UT), which ranks the 10th in Fortune Top 00 in and has its operations in aerospace and

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

Box Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Systemair Box Fans

Box Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Systemair Box Fans Box Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Systemair Box Fans KVD, KVB, KPD & KPB Systemair Group Systemair (Sweden) Systemair (Spain)

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

DEPENDABLE BY DESIGN EASE OF USE PERFORMANCE SERVICEABILITY DURABILITY

DEPENDABLE BY DESIGN EASE OF USE PERFORMANCE SERVICEABILITY DURABILITY FOR VENDED LAUNDRY DEPENDABLE BY DESIGN The Maytag Multi-Load Washer is built to provide the performance and durability your business needs. PERFORMANCE Experience optimal wash performance with a consistent

More information

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51 CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Unit Page CHA/IK/WP - CHA/CLK 8 - CHA/ML/ST - CHA/ML/ST 9 8-9 CHA/ML/ST 8-P 0-P 0 - FROM, KW TO KW. CHA/IK/WP

More information

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series

More information

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013 Replacement Parts List No. 700017400 Revision G 12/2013 Daikin McQuay Incremental Comfort System PKEI, PKES, PKHS 007, 009, 012, 014 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling IBM Symposium 2008 Data Center Cooling EC Systems for HVAC architecture and Direct air Cabinet Cooling Presented by David J. Spofford Product Manager IT/Telecomm 1 Agenda Data Center trends for IT and

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information

Semi-hermetic Air-cooled Condensing Units

Semi-hermetic Air-cooled Condensing Units Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

AuraCool Economizer System

AuraCool Economizer System Page 1 Due to manufacturer's policy of continuous product improvement, the manufacturer reserves the right to make changes without notice. Drawings in this submittal are representations of the equipment

More information

CTC Low Temperature Process Chillers

CTC Low Temperature Process Chillers INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in

More information

Slim duct (AMTTTFNLDEH ) Indoor units

Slim duct (AMTTTFNLDEH ) Indoor units Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative

More information

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C Air Conditioning Technical Data Wall mounted unit EEDEN15-0 FTX-C Indoor Unit FTX-C TALE OF CONTENTS FTX-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

Ecoflair Air Economizers

Ecoflair Air Economizers Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your

More information

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough

More information

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS CHAPTER WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS Unit Page CWW/K 8-9 CWW/K 8-P 0-P 0 - CWW/K 8 0 - MEA/K - MEA/K 8-P 0-P - RCA/K

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change

More information

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class

More information

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners Page 1 of 184 Software for the simulation of refrigeration equipment and air conditioners Index Software for the simulation of refrigeration equipment and air conditioners... 1 : application description

More information

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners DCC Commercial Submittal Data Form 15-25 Tons Packaged Air Conditioners 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h Job Name

More information

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors Aquaflair Air-cooled chillers and free-cooling chillers with double screw compressors BREC & BREF 350-1200kW 380V/3ph/60Hz - 460V/3ph/60Hz The all-in-one solution for your business need Combining cutting-edge

More information

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA181, WA241 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear I TECHNICAL SPECIFICATIONS ROAD BUILDING DDDM 45 (40-60 TPH) DOUBLE DRUM ASPHALT PLANT - DDDM 50 (60-90 TPH) DDDM 60 (90-120 TPH) COLD AGGREGATE FEEDER Stationary four bin cold aggregate feeder unit is

More information

MK SERIES CROSS FLOW COOLING TOWER

MK SERIES CROSS FLOW COOLING TOWER The Ultimate Cooling Machine MK SERIES CROSS FLOW COOLING TOWER CERTIFIED PERFORMANCE DURABLE ENERGY & SPACE SAVING MODEL DEFINITION FOR MK2348E-2BI MK 2348 E 2 B I CROSS FLOW TYPE BOX SIZE MOTOR SIZE

More information

Thermal Design and Management of Servers

Thermal Design and Management of Servers White Paper Thermal Design and Management of Servers Thermal Design and Management of Servers P.1 Overview With the exponential growth of knowledge development, data needs to be stored, processed and secured

More information

Thermal management. Thermal management

Thermal management. Thermal management Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately

More information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread

More information

Outside Plant. Compact Multi-Function Joint - CMJ. Features and Benefits. Prysmian Part Number: CMJ-E-X-XXXX-X-Y-X. Kit Contents. Closure Part Number

Outside Plant. Compact Multi-Function Joint - CMJ. Features and Benefits. Prysmian Part Number: CMJ-E-X-XXXX-X-Y-X. Kit Contents. Closure Part Number Compact Multi-Function Joint - CMJ Prysmian Part Number: CMJ-E-X-XXXX-X-Y-X The Compact Multi Function Joint (CMJ) is for jointing optical fibre cables. The joint is ideal for use as a Cable Chamber Joint,

More information

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2)

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2) DUCT TYPE AIR CONDITIONER (Cool) TYPE ADH4400G DH44ZA(A2) INDOOR UNIT IDH4400A DH44ZA(A2) OUTDOOR UNIT UDH4400G DH44ZAX SERVICE Manual AIR CONDITIONER CONTENTS. Product Specifications 2. Installation 3.

More information

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC: Freecooling Solutions for Increased Data Center Efficiency and PUE of 1.1 Freecooling data center chillers

More information

DCG Commercial. Submittal Data Form

DCG Commercial. Submittal Data Form DCG Commercial Submittal Data Form 15-25 Tons Packaged Gas / Electric Units 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h 25 Tons Cooling Capacity: 290,000 BTU/h 15 Tons

More information

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS). PRODUCT NEWS Products News: New HC-A16KNX PAGE 1 / 8 Summary 1. This advanced product news introduces the new product HC-A16KNX. 2. The details are indicated in the description. Description 1. Applicable

More information

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan DCH Series Submittal Data Form 7½ - 12½ Ton Packaged Heat Pump Up to 11.5 EER & 3.4 COP Cooling Capacity: 90,000 140,000 BTU/h Heating Capacity: 90,000 142,000 BTU/h Job Name Purchaser Order No. Engineer

More information

Type Differential pressure transducer

Type Differential pressure transducer Homepage > Products > Control systems > Control system EASYLAB - LABCONTROL > Sensor systems > Type Differenzdrucktransmitter Type Differential pressure transducer FOR THE DIFFERENTIAL PRESSURE RECORDING

More information

Introducing the Heat Wheel to the Data Center

Introducing the Heat Wheel to the Data Center Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure Specialist KyotoCooling International Critical Facilities Round Table 1 A New Free Cooling Technique

More information

Strip Till. Ultimate in Strip Till Versatility & Performance. The. Toll Free:

Strip Till. Ultimate in Strip Till Versatility & Performance. The. Toll Free: Strip Till The Ultimate in Strip Till Versatility & Performance Toll Free: 1-800-537-7370 www.remlingermfg.com The Original Remlinger Precision Strip Till (PST) row unit was farmer inspired and tested.

More information

CTXA-AS/AT/AW, FTXA-AS/AT/AW

CTXA-AS/AT/AW, FTXA-AS/AT/AW Split Air Conditioning Technical Data CTXA-AS/AT/AW, FTXA-AS/AT/AW > CTXAA2V1BS > CTXAA2V1BT > CTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT > FTXAA2V1BW > FTXAA2V1BS > FTXAA2V1BT

More information

Air Handling Units. With Intelligence

Air Handling Units. With Intelligence Air Handling Units With Intelligence Production facility in India Services on your doorstep STULZ is a global company with headquarters in Hamburg, Germany. 19 Subsidiaries, 9 Production sites and Sales

More information

VIREO Ceiling with ALX

VIREO Ceiling with ALX Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient

More information

FEATURES AND BENEFITS. Installation and operation. Controller

FEATURES AND BENEFITS. Installation and operation. Controller DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.

More information

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors. Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling

More information

Datasheet.

Datasheet. Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk

More information

Cooling of. Offering a safe & reliable way to cool semiconductor equipment & applications SOLUTIONS GUIDE

Cooling of. Offering a safe & reliable way to cool semiconductor equipment & applications SOLUTIONS GUIDE Cooling of Power Electronics Offering a safe & reliable way to cool semiconductor equipment & applications SOLUTIONS GUIDE Bring us your toughest thermal application challenge Mersen will help you maximize

More information

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical

More information

Variable Air Management System. Installation Guide V1.1

Variable Air Management System. Installation Guide V1.1 Variable Air Management System Installation Guide V1.1 Installation Guide Contents 1 - OVERVIEW 2 - INSTALLATION PROCEDURE 3 - TOUCH SCREEN SETUP 4 - TROUBLE SHOOTING 1 2 3 4 Installation Guide V1.1 1

More information

ACFD12-T ACFD12-B. Technical Data

ACFD12-T ACFD12-B. Technical Data TM ACFD12-T ACFD12-B Technical Data Contents Overview.................................................1 Scalable Solution for Critical Environments....................2 Standard Features.........................................5

More information

TEC Unit Conditioner Controller

TEC Unit Conditioner Controller Document No. 540-1026 TEC Unit Conditioner Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2040 and 2041 2050 through 2054 Product Description

More information

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

an EnerSys Company Shelter Cooling Systems

an EnerSys Company Shelter Cooling Systems an EnerSys Company Shelter Cooling Systems Overview Managing the internal temperature within specialist Equipment Shelters is critical when it comes to protecting your sensitive equipment. With over 20

More information

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A CPH Series 7½- to 12½-Ton Self-Contained Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Packaged Heat Pump with R-410A Standard

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

Aquaflair. BREC/F and BCEC/F kw

Aquaflair. BREC/F and BCEC/F kw Aquaflair Air-cooled chillers and free-cooling chillers with screw or oil-free centrifugal compressors equipped with adiabatic system BREC/F and BCEC/F 350-1350 kw Dualism for evolution: the combination

More information