Structured Cable Products Quality Installations Deserve Quality Products
|
|
- Alexis May
- 5 years ago
- Views:
Transcription
1 Structured Cable Products Quality Installations Deserve Quality Products PRODUCT SPECIFICTIONS PRT#: CREST-4 DESCRIPTION: CREST 1 + 4x CT5E 24 WG 4PR UTP, JKT TEL 500 FT SPOOL Edition Established 2013/07/23 Revised pproval Richard Checked John Finish Leo 1 2 1P C 2 D Crest-1 Cat5e Filler Rip cord Standard: UL 444 & UL 13, NEC rticle 760 & NEC rticle 725 pplication: SCP Crest-4 cable bundles four (4) high-quality Cat5e 350 Mhz UTP with our Crest-1 control cable... all under a single jacket. Compare to Crestron's Crescat Q-NP cable. This cable facilitates fast and easy wiring for Crestron Cat5-based V distribution and intercom systems, switchers, room solution boxes, intercoms, and touch panels. SCP's bundled Crest series cables are designed to provide a single cable solution for wiring of Crestron media systems. Characteristics: Stranded are Copper Conductor (CREST-1) Size 18WG X 2C 16/0.254±0.004mm. Thickness 0.24mm 0.27mm 1.70±0.05mm lack & Red Stranded are Copper Conductor Size 22WG X 2C 7/0.254±0.004mm FPE 1
2 . Thickness 0.56mm 0.62mm 2.00±0.05mm lue & White Shield Drain wire(tc) 7/0.20±0.004mm Shield L Foil ssembly(2c+1p) Core wrap PE Tape 0.75mm. Thickness 0.67mm 6.35±0.10mm Teal Solid are Copper Conductor(CT5E) Size 24WG X 4P 1/0.50±0.004mm HDPE. Thickness 0.188mm 0.205mm 0.91±0.01mm lue-white/lue Orange-White/Orange Green-White/Green rown-white/rown 0.60mm. Thickness 0.54mm 5.10±0.10mm Red & White & Green & lue ssembly Filler PP 1CREST-1+4CT5e 14.80±0.20mm 0.75mm. Thickness 0.70mm 16.50±0.20mm Per request 2
3 Electrical & Physical Characteristics - (CREST-1) rating V Conductor Resistance(18WG) Max 22.8ohm/km at 20 Conductor Resistance(22WG) Max 53.5ohm/km at 20 Dielectric Strength C1.5KV C Leakage Current Through overall C 1500V 10m Twists per foot 3.0 ged ged Cold end Test -20 4hours No Cracking STRUCTURED CLE PRODUCTS --- P/N CREST C/22 WG C STRNDED SHIELDED W/DRIN + 2C/18 WG C STRNDED CMR FT4 75C -- (UL) OR C(UL) E CE EU RoHS EC ZONE/DEVICE E XXXXFEET Electrical & Physical Characteristics - (CT5e) rating 75 30V Conductor Resistance Max 93.8ohm/km at 20 Dielectric Strength C1.5KV Spark Test 5.0KV C Leakage Current Through overall C 1500V 10m Tensile Strength 16.5 Mpa Elongation 500% ged Tensile Strength 14.2 Mpa( h) Elongation 250%( h) ged Cold end Test -20 4hours No Cracking DC Resistance Unbalance Max 5% Pair-to-Ground Capacitance Unbalance Max 3300pF/km 3
4 Characteristic Impedance 1~350MHZ 100±15OHM Nominal Velocity of Propagation (%) 67~69 Propagation Delay 350MHZ Max 536ns/100m Delay Skew 1~350MHZ Max 45ns/100m STRUCTURED CLE PRODUCTS --- P/N CT5E --- CT5E ENHNCED 350 MHz 4 PR 24 WG UTP VERIFIED TO NSI/TI-568-C.2 CMR FT4 75C -- (UL) OR C(UL) E CE EU RoHS EC ZONE/DEVICE E XXXXFEET Performance-1 ITEM Performance-2 ttenuation Max (d/100m) NEXT PS NEXT CR Frequency Standard SCP Standard SCP Standard SCP Standard SCP ITEM Frequency RL ELFEXT PS ELFEXT PSCR Standard SCP Standard SCP Standard SCP Standard SCP
5 STRUCTURED CLE PRODUCTS --- P/N CREST x CT5E ENHNCED 350MHZ 24 WG UTP + 2C/22 WG C STRNDED SHIELDED W/DRIN + 2C/18 WG C STRNDED - UNDLED CMR FT4 75C -- (UL) OR C(UL) E CE EU RoHS EC ZONE/DEVICE E XXXXFEET Packaging: pprox. Weight(kg) pprox. Dimension(mm) package Packages per Pallet X350X200X ft/spool 12/8 5
121700A Paired - Category 5e DataTuff Twisted Pair Cable
For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents : No. 8 for DataTwist Cables (Modified Western Electric).pdf Description: 24 AWG Bonded-Pairs solid bare copper conductors,
More informationDetailed Specifications & Technical Data
Description: (1) coax-20 AWG solid BC cond., gas-injected foam HDPE insul., 95% BC braid shield, PVC jkt., cabled with (1) pair-18 AWG stranded (19x30) BC cond., PO insul., Beldfoil shield, PVC jkt., cabled
More informationDetailed Specifications & Technical Data
Description: 18 AWG stranded (19x30) TC conductors, polypropylene insulation, twisted pairs, individually shielded w/beldfoil (100% coverage), 20 AWG stranded TC drain wire, PVC jacket. Physical Characteristics
More informationDetailed Specifications & Technical Data
: 18 AWG stranded bare copper conductors, Flamarrest insulation and jackets, no overall jacket, all cables are Beldfoil shielded, cable jackets are color coded by application, individual jacket is sequentially
More informationRun lots of CAT5 and CAT5e cable to support different high-speed applications and know at a glance which cable is for which purpose.
2007. All rights reserved. Black Corporation. FREE 24-hour Tech Support: 724-746-5500 blackbox.com CAT5/CAT5e Shielded and Unshielded Cables Run lots of CAT5 and CAT5e cable to support different high-speed
More informationCat 6 (500 MHz) UTP solid cable (PVC sheath)
JetLan is the only structured cabling system that includes all the passive elements required by the installation or modification of your data networks, as it offers all the options for high performance
More informationDetailed Specifications & Technical Data
Description: 22 AWG stranded (7x30) tinned copper conductors, semi-rigid PVC insulation, twisted pairs, overall Beldfoil (100% coverage) + tinned copper braid shield (65% coverage), PVC jacket. Physical
More informationEthernet Series. Etherplug Etherlink V Etherlink V Specifications Ethernet Series
Etherplug... 10-113 Etherlink V3...114-116 Etherlink V1... 117-120 Specifications..121-122 107 Mencom Corporation TEL: 770-534-455 www.mencom.com Etherplug Cordsets PVC & PUR Cable Pole PVC Version of
More informationWEST PENN WIRE Special Application Cables
VG INPUT MONITOR OUT VG INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R udio L R udio UDIO INPUTS + - + - UDIO INPUTS + - + - MPLIFIED OUTPUT 4/8 ohm COM 70V 100V MPLIFIED OUTPUT 4/8 ohm COM
More informationContents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06
Contents Cat6 Structured Cabling Solutions U/UTP Cabling Solutions Structured Cabling Solutions LAN Cables... 03 Patch Cords... 04 Connectors... 05 Patch Panels... 06 U/FTP Cabling Solutions LAN Cables...
More informationTECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5
page 1/5 Application: High Density Switch & Hub Working area cord and telecommunications equipment cord in Local Area Networking environments Support current and future Category 6 applications, such as:
More informationCompact Module. Enhanced Category 5 UTP Cabling System
Compact Module Suitable for Gigabit Ethernet applications Shallow design requires minimal back-box depth Interchangeable with other Euro modules and 1 4 blanks Industry standard IDCs Individually QA tested
More informationSYSTEM CJ TELEPHONE JACKS & MODULAR PLUGS
SYSTEM TELEPHONE JKS & MODULR PLUGS vilux Introduction System contains splice termination regular modular plugs, category 5 modular plugs and board mount and surface mount telephone jacks. The modular
More informationCopper Structured Cabling Solutions
Copper Structured Cabling Solutions Optronics An industry leader in enterprise connectivity About Us Optronics products provide a comprehensive range of premium end-to-end fibre optic connectivity and
More informationStandard Buccaneer - Ethernet
IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB
More informationResidential Cables. Table of Contents
21.1 Table Contents Residential Cables 21 Residential Cables Page Introduction 21.2 Coposite Data, Audio, Video, Security and Control Cable 21.3 21.8 Banana Peel Jacketless Cables: Category 5e 21.3 Jacketed
More informationSubmittal Approval Form
Submittal Approval Form PROJECT: CLAY SPRINGS ELEMENTARY SCHOOL DATE: 2/17/15 SUBCONTRACTOR NAME: Tri City Electric SUBCONTRATOR ADDRESS: NUMBER AND TITLE OF SPECIFICATION SECTION: 28 13 10 Electronic
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables Cable Spools Unshielded Twisted
More information9/27/04 cci Cablecom Inc. 1
cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local
More informationFT1R / FT1R-J Multi-Media Cable
FT1R / FT1R-J Multi-Media Cable APPLICATIONS The FT1R / FT1R-J multi-media Cable consists of two (2) RG6 quad shield coax cables and two (2) CAT5e twisted pair cables. Installers can choose between speedwrapped
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables 0 Cable Spools Unshielded
More informationSpecial Application Cables
Special Application s West Penn Wire offers a variety of cables that meet special needs or specific applications. Most of the Special Application s manufacturered is the result of us listening to you,
More informationintegrated markets Voice, Data & Video
integrated markets Voice, Data & Video A tradition of excellence... Exceptional Performance. Coleman Cable Inc. is a worldwide leader in the development, design, manufacturing, marketing & distribution
More informationBULLETIN. Surveillance System Camera Technology
NP 216 BELDENCableTM To suit your CCTV/Surveillance installation needs, Belden offers Banana Peel Composite cables for pan/tilt/zoom (PTZ) cameras and a wide range of single coaxes, coaxial/twisted pair
More informationBULLETIN. Surveillance System Camera Technology
NP 216 BELDENCableTM To suit your CCTV/Surveillance installation needs, Belden offers Banana Peel Composite cables for pan/tilt/zoom (PTZ) cameras and a wide range of single coaxes, coaxial/twisted pair
More informationNetwork Fundamentals and Cabling TELECOMMUNICATION AND NETWORKING
Network Fundamentals and Cabling TELECOMMUNICATION AND NETWORKING Computer Networks Defined as having two or more devices (such as workstations, printers, or servers) that are linked together for the purpose
More informationStandard Buccaneer - Ethernet
IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB
More informationStandard Analog Video Cable 75 Ohm Miniature Coax
C O A X I A L C A B L E S 6.34 75 Oh Miniature Coax 30 AWG Stranded (7x38).012 Tinned Copper Tinned Copper Braid Shield (89% Coverage) Foa HDPE Insulation Black PVC Jacket Diaeter DCR Shielding OD Inch
More informationANSI/TIA-568-C Cat 6 Field Test Specifications
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6 Permanent Links. It is offered as a general guide. Suitability
More informationCompact Module. Category 6 UTP Cabling System
Compact Module Suitable for Gigabit Ethernet applications Shallow design requires minimal back-box depth Interchangeable with all other Euro modules and quarter blanks Fits all standard Euro faceplates
More informationUTP Cat 5e cable (200 MHz) (PVC sheath)
JetLan is the only structured cabling system that includes all the passive components required for the installation or adaptation of your data network, as we include all the different types of high performance
More informationEthernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety.
Table of Contents Guide...7-2...7-3 Unshielded Twisted Pair...7-5 Shielded Twisted Pair...7-6 600V Ethernet Cable...7-7 Cordsets & Patchcords RJ45...7-9 M12 Flex-Rated...7-10 M12 Receptacle Flex-Rated...7-12
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More informationEthernet 10Base-T Hub EH-500 EH-800A EH Rev. 3.0
Ethernet 10Base-T Hub EH-500 EH-800A EH-1600 Rev. 3.0 Trademarks Copyright PLANET Technology Corp. 1998. PLANET is a registered trademark of PLANET Technology Corp. The information in this manual is subject
More informationComplete the Installation SKINTOP MS-SC. Approvals: Approx. SKINTOP Part
ETHERLINE HEAT 6722 Flexible special Ethernet cable for high-temperature applications ETHERLINE HEAT 6722 ETHERLINE HEAT 6722 ETHERLINE HEAT 6722 Insulation: polyolefin wrapped with special fire-retardant
More informationGORE Aerospace. Reliable signal transmission in high-density, lightweight constructions. high speed data cables. For Military Applications
For Military Applications Reliable signal transmission in high-density, lightweight constructions Engineered for demanding aerospace environments, GORE Aerospace High Speed Data Cables are constructed
More informationANSI/TIA-568-C Cat 6A Field Test Specifications
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6A Permanent Links. It is offered as a general guide. Suitability
More informationDriveRack. /ZonePRO. ZC Series Wall-Mounted Zone Controllers ZC Series. User Guide. ZC-1-4 ZC-6-9 ZC-Fire ZC-BOB
DriveRack /ZonePRO ZC Series Wall-Mounted Zone Controllers ZC Series ZC-1-4 ZC-6-9 ZC-Fire ZC-BOB User Guide DECLARATION OF CONFORMITY Manufacturer s Name: Manufacturer s Address: db Professional Products
More information10 million cycles at 20 x diameter (TPE cable)
Ethernet Media Cable Spools Unshielded Twisted Pair Unshielded Spool Rockwell Automation s Cat5e shielded and unshielded cable is designed to supply a reliable network connection in harsh surroundings.
More informationFamily of Cords SYSTIMAX. Structured Cabling Systems. Quality Stranded and Solid Cords That Connect Data and Voice Circuits
SYSTIMAX Structured Cabling Systems Family of Cords Quality Stranded and Solid Cords That Connect Data and Voice Circuits Lucent Technologies Family of Stranded Cords includes 110 patch, modular and adapter
More informationPatch Cords. Handset Cord...Page 46. Category 6 Patch Cords...Page 42. Category 5e Patch Cords...Page 42. Modular Extension Cord...
Patch Cords The Professional s Choice. VIP2000 Jacks Inserts Allen Tel Products, Inc. offers a complete line of high performance for copper and fiber applications. Our modular products also include telephone
More informationCat.8 Shielded Field Termination Plug Description
Description RiT s CAT8 Shielded field termination plug are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations.
More informationCONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.
Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit
More informationSolution of Exercise Sheet 2. (Layers of Reference Models)
Solution of Exercise Sheet 2 Exercise 1 (Layers of Reference Models) 1. Fill in the names of the layers of the reference models in the figure. 2. Assign to technical terms Frames, Packets, Segments and
More information10 million cycles at 20 x diameter (TPE cable)
Unshielded Twisted Pair Unshielded Ethernet Cable Spool robust thermoplastic elastomer (TPE) jacket, data is protected from noise, chemicals, and mechanical issues to Two and four pair TPE robotic flex
More informationLN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note
LN Series Input/Output (I/O) Extension Modules and LN Communicating Sensors Subnetwork for LN-VAVCF-12 and LN-PRGxxx-12 Application Note LN-IOE400-0, LN-IOE410-0, LN-IOE420-0, LN-VAVCF-12, LN-PRGxxx-12
More informationEXTENDER ELE8081. INSTALLATION Manual. Made in Taiwan
EXTENDER ELE8081 INSTALLATION Manual Made in Taiwan Safety and Notice The ELE8081 HDMI EXTENDER has been tested for conformance to safety regulations and requirements, and has been certified for international
More informationUSB 3.1 CAT6A/7 EXTENDER
USER MANUAL ICU504A USB 3.1 CAT6A/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM Power Mode Config Status Link Video USB 2 USB 3 Power Mode Config Status Link Video USB 2 USB 3 TABLE OF CONTENTS PRODUCT OPERATION
More informationPREMISE & FIBER OPTIC CABLE CATALOG
PREMISE & FIBER OPTIC CABLE CATALOG PREMISE & FIBER OPTIC CABLE Since 1986, Hitachi Cable has been developing technologically advanced copper and fiber optic communication cables. Our dedication to engineering
More informationLP-4CEUSXX Cat 5e Unshielded U/UTP Patch Cords
Cabling - Copper Solutions LP-4CEUSXX Cat 5e Unshielded U/UTP Patch Cords LP4CEUSXX_SS_ENB01W Features Unshielded snagless U/UTP Patch Cords. UL, CSA approved. ETL verified. Cat 5e patch cords are backward
More informationModular plugs, accessories and tooling
Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for
More informationDXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables. By Scott MacDonald, KD8BDX. Parts list:
DXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables By Scott MacDonald, KD8BDX needing the flexibility of custom wiring length and being comfortable with terminating
More informationContents 9-1. Network Media
Contents General Information Quick Selection Guide... page 9--2 Introduction... page 9--3 Ethernet Media Cordsets & Patchcords Cable Spools... page 9--4 Cordsets & Patchcords... page 9--5 Field Attachable
More informationEXTENDER ELE8082. INSTALLATION Manual. Made in Taiwan
EXTENDER ELE8082 INSTALLATION Manual Made in Taiwan Safety and Notice The ELE8082 HDMI EXTENDER has been tested for conformance to safety regulations and requirements, and has been certified for international
More informationInstallation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data
Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data Publication January 2014, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com
More informationData sheet C6 A modul 90 jack
Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: module, 90 cable feed solid,
More informationB.T.C. Iberica Instrumentation Cable
B.T.C. Iberica Instrumentation Cable Single & Multi-Pair, XLPE-Insulation, Collective Screen, LSZH-Sheath 70º / 300/500 Construction Conductor Plain, annealed copper, sizes:, 1.0mm²,, 0.75mm² or 1.5mm²
More informationMODULAR PLUGS, ACCESSORIES AND TOOLING
MODULAR PLUGS, ACCESSORIES AND TOOLING 4th Edition Introducing the New Universal Contact BROADBAND NETWORK SOLUTIONS /// MODULAR PLUGS, ACCESSORIES AND TOOLING TE CONNECTIVITY MODULAR PLUG PORTFOLIO TE
More informationCable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.
Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications Broadband High-Speed LAN Voice Robert Y. Faber Jr., RCDD/NTS Minimum Port Recommendations TIA/EIA-568-B.1 2 outlets
More informationCat.8 Shielded Keystone Jack Description
Description RiT s CAT8 Shielded Keystone Jacks are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations. Phosphor
More informationNetwork Media and Layer 1 Functionality
Network Media and Layer 1 Functionality BSAD 146 Dave Novak Dean, Chapter 3, pp 93-124 Objectives Introduction to transmission media Basic cabling Coaxial Twisted pair Optical fiber Basic wireless (NIC)
More information10 million cycles at 20 x diameter (TPE cable)
Ethernet Media Cable Spools Unshielded Twisted Pair Unshielded Spool Rockwell Automation s Cat5e shielded and unshielded cable is designed to supply a reliable network connection in harsh surroundings.
More informationInstallation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data
Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data Publication January 2014, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com
More informationField-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.
FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color
More informationPGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-6100 PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 2-C-050818 Copyright 2018 Littelfuse All rights reserved. Document
More informationBUS UNITRONIC BUS DeviceNet Gray
BUS UNITRONIC BUS DeviceNet Gray For DeviceNet bus systems; stationary applications; UNITRONIC UNITRONIC DeviceNet THIN UNITRONIC BUS DeviceNet cables provide reliable data and power transfer between industrial
More information3M Category 6 Copper Structured Cabling System
Communication Markets Division 3M Category 6 Copper Structured Cabling System 3M RJ45 Category 6 Jacks UTP PL 3M Copper Patch Cords 3M Copper Patch Panels 3M Faceplates & Wall Outlets 3M Copper Cable 3M
More informationNEW. Phone: Fax: Web: -
NEW 8-port unmanaged switch in IP67 Just 54 mm wide One LED per port for link / speed / data Fault relay: 1 x M12 A-coded, 5-pole (24 V DC / 1 A) 8 x M12 D-coded, 4-pole Redundant voltage supply 2 x M12
More informationBuilding Reliable Results
LOW VOLTAGE WIRE AND CABLE FOR VOICE & DATA SATELLITE TV, CATV CCTV, AND SECURITY STRUCTURED VOICE AND DATA CONNECTIVITY AND RF DEVICES NETWORK COMMUNICATIONS is a subsidiary of NETCOM which owns and operates
More informationMIL- C-17G QPL Cable Twinax
C O A X I A L C A B L E S 6.81 MIL- C-17G QPL Cable Twinax Twinax 24 AWG Stranded (19x36).024 Silver-coated High-Strength Copper Alloy SCHSCA Braid Shield (93% Coverage) TFE Teflon Insulation Blue PFA
More informationRugged USB Solutions USB3.0
Rugged USB Solutions USB3.0 NEW table of contents NEW USB3.0 Field installable USB3FTV (USB-A)... 88 USB3F TV - Transversally sealed receptacles... 92 USB3F TV - Hermetic receptacles... 95 USB3 receptacle
More informationNever Beaten by Seasons
Never Beaten by Seasons Buccaneer For Data Frozen Winters! Torrential Springs! Blistering Summers! Dusty Autumns! The Buccaneer range of IP68 waterproof connectors for Ethernet, USB, Mini USB and FireWire.
More informationThe Multi-core Coloured Soft Control Cables
VCT-F The Multi-core Coloured Soft Control Cables 16core X 0.3 2 colour available in Grey or Black Cold Resistant -25 C Heat Resistant +60 C Application control cables covers all electrical installation
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationUSB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide
USB 3-2-1 Raven 3104 4-Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3104. Please read this guide thoroughly. This document applies
More informationCategory 5e Solutions
Introduction... 5.2 Cable... 5.3 Patch Panels... 5.4 Modules... 5.5 Patch Cords... 5.8 Mutos and Consolidation Points... 5.13 Outlets... 5.14 www.adckrone.com AUS 1800 801 298 NZ 0800 657 663 5.1 Introduction
More informationData sheet C6 A modul 1 port 180 M AP pure white
Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification surface-mount termination unit with C6modul 180 certified to GHMT Cat.6 re-embedded PVP component
More informationComplete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter
BUS UNITRONIC BUS PB For PROFIBUS-DP/FMS/FIP bus systems; stationary applications; 150 Ω UNITRONIC BUS PB UNITRONIC BUS PB FC UNITRONIC BUS PROFIBUS cables are designed for automation networks requiring
More informationModular plugs, accessories and tooling
Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for
More informationSP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan
SP-1014 1x4 DVI over Single CAT5 Distribution Amplifier User Manual Made in Taiwan Safety and Notice The SP-1014 1x4 DVI over Single CAT5 Distribution Amplifier has been tested for conformance to safety
More informationUSB 2.0 CAT5E/6/7 EXTENDER
USER MANUAL IC402A-R2 USB 2.0 CAT5E/6/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM + + + + Mode Config Power Link Host Activity Power Link Host Activity TABLE OF CONTENTS PRODUCT OPERATION AND STORAGE... 3
More informationB.T.C. Iberica Instrumentation Cable
Instrumentation Cable Multi-Core, PC-, Collective Screen, PC-Sheath 70º / 300/500 Construction Conductor Plain, annealed copper, sizes:0.5mm² multistranded, 0.75mm² mulitistranded, or 1.5mm² stranded Polyvinyl
More informationChapter 3 Certifying Twisted Pair Cabling
Chapter 3 Certifying Twisted Pair Cabling Setting the Reference The reference procedure sets a baseline for insertion loss, ELFEXT, and dc resistance measurements. Run the tester s reference procedure
More informationUNIVERSITY OF CALICUT (Purchase Division)
No. 12831/PURCHASE-ASST-A1/2013/CU UNIVERSITY OF CALICUT (Purchase Division) Calicut University. P.O., Dated, 07.06.2013. TENDER NOTICE Sealed and competitive tenders are invited for the installation of
More informationPGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationFX-2 Control Board ASY-360-XXX Setup and Configuration Guide
FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...
More information3M Cold Shrink QS-III Inline Splice Kits 15 kv 5415A, 5416A, 5417A, 5417A-WG, 5418A and 5418A-WG
3M Cold Shrink QS-III Inline Splice Kits 15 kv Data Sheet July 2013 Jacketed Concentric Neutral (JCN) 5415A, 5416A, 5417A, 5418A Concentric Neutral (JCN) 5417A-WG and 5418A-WG! CAUTION Working around energized
More information3M Cold Shrink QS4 Integrated Splice Kits 35 kv
3M Cold Shrink QS4 Integrated Splice Kits 35 kv 1/0-350 For Jacketed Concentric Neutral (JCN), Flat Strap, Tape Shield and Longitudinally Corrugated (LC) Cables Data Sheet July 2014! CAUTION Working around
More informationThe Real Impact of High Power PoE on Your IP Network
The Real Impact of High Power PoE on Your IP Network Jason Finnegan, Product Manager Copper Solutions, Legrand Cindy Montstream, Director of Technical Support & Training, Legrand Amir Sekhavat, Global
More informationIMPORTANT PRODUCT INFORMATION
November 13, 1999 IMPORTANT PRODUCT INFORMATION READ THIS INFORMATION FIRST Product: Control Station Hardware Products (Operator Control Station [OCS], Remote Control Station [RCS]) IC300OCS100, IC300OCS200,
More information3M Cold Shrink QS-III Inline Splice Kits 25/28 kv 5456A, 5456A-WG, 5457A, 5457A-WG, 5458A and 5458A-WG
3M Cold Shrink QS-III Inline Splice Kits 25/28 kv 5456A, 5456A-WG, 5457A, 5457A-WG, 5458A and 5458A-WG Data Sheet July 2013 Jacketed Concentric Neutral (JCN) 5456A, 5457A and 5458A Concentric Neutral (JCN)
More informationThe Real Impact of High-Power PoE on Your IP Network
The Real Impact of High-Power PoE on Your IP Network Jason Finnegan, Product Manager Copper Solutions - Legrand Cindy Montstream, RCDD, NTS - Director of Technical Support & Training - Legrand Brian Ensign,
More information3M Interconnect Products. MDR Connector Selection Guide
3M Interconnect Products MDR Connector Selection Guide 3 High Speed MDR Cable Assemblies 3M Mini Delta Ribbon (MDR) High Speed Transmission System The 3M MDR High Speed Transmission System is a digital
More informationCable Design Criteria
Cable Design Criteria (Group) Construction (0 Pairs) Each sub-unit (group) made up of quads (0 pairs) 0 0 (Group) Construction made up of 0 Pairs Unit or Core Construction of Telephone Cables Up to 00
More informationNETWORKING SOLUTIONS NETWORKING SOLUTIONS. freephone
Networking Products by C2G support the rigorous demands of enterprise applications. From 10Gb Aqua Fibre and LSZH Fibre to Cat6 and Cat5e Cables, C2G has the products to keep up with your ever-increasing
More informationRugged MediaConverter
Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006
More informationFinolex. Net. Bandwidth and Speed in the Ultimate Lan Cabling Solutions. years FINOLEX 25 PAIR CAT-5 LAN CABLES INDOOR AND AERIAL
PR CT5 LN CBL NOOR N RL The pair Cat5 LN cable for indoor application consists of a solid bare annealed copper conductor of 24 W (0.5 mm), insulated with High ensity Polyethylene compound, colour coded,
More informationThis Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.
This Datasheet is for the IC6CBL00 I/O Bus Expansion Cables http://www.qualitrol.com/shop/p-45-ic6cbl00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 0-0 module. For
More informationB.T.C. Iberica Instrumentation Cable
Multi-Core, PC-Insulation, Collective Screen,, PC-Sheath Construction Conductor Plain, annealed copper, sizes:0.5mm² multistranded, 0.75mm² mulitistranded, or 1.5mm² stranded Insulation Polyvinyl chloride
More information[0.057] 5.8 [0.23]
Product Specification 7 June 13 Rev B SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used
More information