Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data
|
|
- Lambert Craig
- 5 years ago
- Views:
Transcription
1 Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data
2 Publication January 2014, Keyprocessor BV Paasheuvelweg BJ Amsterdam, The Netherlands Tel.: This manual represents the knowledge at the above mentioned time. Keyprocessor works nonstop to improve her products. For the most recent technical information please contact your consultant or dealer. Content overview Publication... 2 Content overview The product Sticker i-serie Spacers Reader configuration LEGIC prime programmable Installation and use Location Mounting instructions Use of the i80l/p Connection Sirius i80l connector lay-out If door controller Polyx Direct connection (RS485) Connection using an Adapterboard If door controller Orbit Connecting with UTP cable Connection with CKY 3x2x0,14mm² Technical data Cable specifications Data signal Clock/Data Data signal Wiegand Data signal RS Certificates... 14
3 1 The product The Sirius i-series LEGIC card reader is a versatile card reader which supports the LEGIC card read protocol. This manual provides the necessary information concerning the installation instructions, mounting and use of the card reader which is supplied as standard. The Sirius i-series LEGIC card reader: Sirius i80 L Sirius i80/lp 1.1 Sticker i-serie On the back of the card reader a sticker placed. This sticker features a QR code. After scanning this QR code, all necessary information will be downloaded automatically. 1.2 Spacers The spacer is designed for the following purpose. It can make the card reader more robust for external influences but it can also be useful when installing the Sirius card reader on existing plants Sirius i80l(p) Spacer Sirius i80l(p) outside mounting spacer
4 1.3 Reader configuration When using the Sirius i-serie, the following LEGIC configuration is possible. The configuration is described in the paragraph below. Remark: For more information about the additional options, please contact your contact at Keyprocessor. Remark: The Sirius-i80LP (Pincode) card reader will only work in combination with a Polyx door controller LEGIC prime programmable Part number: I80L I80Lp Standard communication: An Polyx based on RS485 An Orbit based on Clock/Data or Wiegand. Output length when using Clock/Data, Wiegand, RS485: Depending on the card data and programmed settings. Standard LED function When the reader is provided with power, the LED color is red. When the LED connection is switched to GND, the LED color is green. Standard IO function: A standard configured card reader does not use the extra IO functionality. When this function is needed, you need to order another card reader. Programmable: The card reader is programmable with the supplied program tool. For more information, see the Sirius program tool manual.
5 2 Installation and use By the use of ferrite, the card reader is insensitive to be installed on a metal surface. 2.1 Location Determine the location where the Sirius card reader should be installed. There is a maximum cable length between the reader and door controller. Exception: using an external power supply, you can increase the achievable distance between the door controller and card reader. Install the reader with a minimum lateral distance of 20 cm from each other. 2.2 Mounting instructions Mount the card reader preferably on an outlet Picture 1: Sirius i80l measurements Pull the cable through the mounting plate of the Sirius reader. The screw hole of the card reader should be placed on the underside. Mount the back plate of the card reader to the outlet, using the existing screws. When not removed, remove the orange colored film of the Buzzer Click the front of the card reader at the top of the mounting plate Attach the front of the card reader to the mounting plate with the supplied 'special mounting bolts.
6 2.3 Use of the i80l/p When entering the PIN code, the finger must be released at least 1 cm from the panel before the next digit is entered.
7 3 Connection Remark! Depending on the configuration of the card reader, the inputs and outputs of the card reader can be used. 3.1 Sirius i80l connector lay-out Connect the cable as shown in this chapter Pin number Clock/Data Wiegand RS485 7 Vcc (+) Vcc (+) Vcc (+) 6 GND (-) GND (-) GND (-) 5 Ext. Input 1(LED) Ext. Input 1(LED) Ext. Input 1 4 Clock D1 Ext. Output 2 3 Data D0 Ext. Output 1 2 Ext. Input 2 Ext. Input 2 B 1 Ext. Output 1 Ext. Output 1 A The reader accepts a supply voltage of VDC. A higher input voltage results in a lower power consumption and provide cost-effective wiring with a smaller diameter of the conductor. When using an external power supply, it must comply with the SELV guidelines.
8 3.2 If door controller Polyx The Sirius card reader can be connected in two ways with the Polyx : directly or by using an Adapterboard For optimal communication, it is recommended to have the latest version of one of the following operating system 2.6 JFSS2 3.3 UbiFS Remark! Browse to the polyx to see the version information. For more information about the versions, see the KP_Install_update_Polyx manual Direct connection (RS485) Recommended cable type between a Polyx and the Sirius card reader is: (4.1 for more information) CAT5 UTP four twisted pairs of 24AWG copper conductors CAT6 UTP four twisted pairs of 24AWG copper conductors A direct connection (without using an Adapterboard) between the Sirius card reader and a Polyx is NOT possible when: Sirius and Polyx are installed in different buildings and thus the connection leaves the building or the wiring is no UTP cable (CAT5 or CAT6) or an existing (non UTP) cable is reused or overvoltage protection for the card reader is required or An external power supply is required for the card reader. If any of the above conditions applies, see chapter Polyx, directly connected to a Sirius card reader: Picture T-568B Pin number RJ- 45 Plug Polyx PRT 2/3 TIA/EIA-568-B Cable color Signal Connection Sirius i30 card reader 1 White/orange B 2 2 Orange A 1 3 White/green B 2 4 Blue Vcc (+) 7 5 White/blue 6 Green A 1 7 White/brown 8 Brown GND (-) 6
9 3.2.2 Connection using an Adapterboard Recommended cable type between a Polyx and the Sirius card reader, using an Adapterboard is: Shielded cable with twisted pairs If a direct connection is not possible, an Adapterboard must be placed between Polyx and the Sirius card reader. Adapterboard and Polyx are connected with a default UTP cat5 cable (or higher) (plug connection). Connecting wires as shown in the diagrams below. Or screw connection on Adapterboard Or RJ45 connection on Adapterboard TIA/EIA-568-B Cable color Signal Connection Sirius i80 Sirius i80(/p) card reader A (or 1) 1 White/orange B 2 B (or 2) 2 Orange A 1 Y (or 3) 3 White/green B Blue Vcc (+) 7 5 White/blue Z (or 6) 6 Green A 1 7 White/brown 8 Brown GND (-) 6 Connect GND of the Adapterboard to the local Earth. Connect the shield of the ground cable to the GND connection of the Adapterboard. Do not place any jumpers! For more information see the Adapterboard manual. Possible connections of the card reader Sirius on the Adapterboard 3.3 If door controller Orbit Recommended cable type between the Orbit and Sirius card reader: CKY 3x2x0,14mm² CKY 4x2x0,14mm² CAT5 UTP four twisted pairs of 24AWG copper conductors CAT6 UTP four twisted pairs of 24AWG copper conductors
10 3.3.1 Connecting with UTP cable TIA/EIA-568-B Cable color Connection on the Orbit Connection Sirius i80 card reader White/orange Data/D0 3 Orange - - White/green Clock/D1 4 Blue +5V 7 White/blue LED 5 Green - - White/brown GND 6 Brown GND Connection with CKY 3x2x0,14mm² Cable color Connection on the Orbit Connection Sirius i80 card reader Green Data/D0 3 Yellow Clock/D1 4 Pink +5V 7 Grey LED 5 White GND 6 Brown GND 6
11 4 Technical data Model Sirius i80 card reader Interface Sirius Clock/Data, Wiegand Sirius - Polyx (RS485) Data type Read Read/write Readable cards LEGIC prime LEGIC prime Power supply 5-16V DC Average: 0,7W Peak: 1,4W Led consumption, both on On 12V, max. 1,8W 100% LED input LED input with pull-up, active low Ext. output Ext. input 1 Dimensions (mm) i80 Reading Distance i80 Environmental Rating i V DC Average: 0,7W Peak: 1,4W max. Voltage 45V; Open collector output; sinked current. Max. current 500mA Resistance 1kOhm 142x45x22 5mm-70mm for LEGIC prime IP64 Operating Temperature -31º to 150º F (-35º to 65º C) Storage Temperature -67º to 185º F (-55º to 85º C) Operating Humidity 5% to 95% relative humidity non-condensing Transmit Frequency MHz Indicators 2x RGB LED and 1 buzzer Connection 7-pin screw connector Certifications CE
12 4.1 Cable specifications Cable specifications (non-shielded) min.conductor size with Maximum cable length 12 VDC supply 1 = 5V DC Interface Meters Feet mm 2 AWG Wiegand Clock/Data RS485 (cable power) RS485 (external power) Data signal Clock/Data Data signal Wiegand
13 4.1.3 Data signal RS485
14 4.2 Certificates
Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data
Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data Publication January 2014, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com
More informationInstallation manual PHG Finger scan reader. o Connecting the reader o Enrollment station o Wall mounted reader o Use of the reader
Installation manual PHG Finger scan reader o Connecting the reader o Enrollment station o Wall mounted reader o Use of the reader Publication October 2014, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam
More informationInstallation instructions Modular controller line. Pluto Orion
Installation instructions Modular controller line Pluto Orion Document date: 05072018 1 About this publication July 2018, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam The Netherlands www.keyprocessor.com
More informationInstallation instruction. Polyx. Functions Connections Mounting Installation diagnosis
Installation instruction Polyx Functions Connections Mounting Installation diagnosis 2 Impressum April 2012, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, Netherlands www.keyprocessor.com Tel.: +31-20-4620700
More informationOrion bus communication iprotect 8.03
Orion bus communication iprotect 8.03 o Basic implementation Guide lines 1 Publication June, 2015 Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam www.keyprocessor.com Tel.: +31-20-4620700 This manual
More informationREX F-0-9 Standalone or Access Controller
REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes
More informationTechnical Manual Nova: Cabinet Security Management System (CSMS)
Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova
More informationLantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual
Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationMS-7000: SuperStar Reader
The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi
More informationMS-4000: ShootingStar Reader
: ShootingStar Reader The ShootingStar Reader The ShootingStar Reader is intended for installation on a solid metal surface, in proximity applications where a vandal-proof reader is required. The reader
More information-C5RS-LC RS232 EXTENDER
XTENDEX Series ST-C5RS-LC RS232 EXTENDER Installation and Operation Manual ST-C5RS-LC RS232 Extender Man249 Rev. 10/30/17 TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the
More informationMS-5000: MiniStar Reader
The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also
More informationMS-3000 MicroStar Reader
MicroStar Reader The MicroStar Reader The MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required.
More informationIndustrial 1-Port Coax/UTP Long Reach PoE+ 4-Port. 10/100TX PoE Extender LRP-104CET. User s Manual
Industrial -Port Coax/UTP Long Reach + -Port 0/00TX Extender User s Manual Table of Contents. Package Contents.... Application Diagram.... Point to Multi-point..... LRP-0CH to..... LRP-0UH to... 5. Multi-Point
More informationGV-EL124S Electric Strike
GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either
More informationNever Beaten by Seasons
Never Beaten by Seasons Buccaneer For Data Frozen Winters! Torrential Springs! Blistering Summers! Dusty Autumns! The Buccaneer range of IP68 waterproof connectors for Ethernet, USB, Mini USB and FireWire.
More informationMS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications
The MiniStar Reader The MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also be mounted directly
More informationInstallation manual for for Schleifenbauer DPM3
Installation manual for for Schleifenbauer DPM3 Installatie handleiding voor Schleifenbauer DPM3 Installationsanleitung für Schleifenbauer DPM3 Guide d installation du Schleifenbauer DPM3 Installation
More information4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT
4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with
More informationPR602LCD v1.0 Installer Manual Rev. A
PR602LCD v1.0 Installer Manual Rev. A Introduction This document contents minimum information required for electrical connections and installation of the PR602LCD access controller in Roger Access Control
More informationInstallation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B
Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its
More informationAdapter Kit - Remote QSI Electronics Installation Instructions
Adapter Kit Remote QSI Electronics Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics. The instructions
More informationUSB 2.0 RG port USB m Cat 5e Extender System. User Guide
USB 2.0 RG2204 4-port USB 2.0 100m Cat 5e Extender System User Guide Thank you for purchasing the USB 2.0 RG2204. Please read this guide thoroughly. This document applies to Part Numbers: 01-00294, 01-00295,
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More informationInstallation and Operation Manual
Installation and Operation Manual ET1100C Series Ethernet Extender Series Microtype10/100BASE-TX Ethernet Extender over Coaxial Cable OT Systems Ltd., 2014 Rev 1.1 www.ot-systems.com 1 Models covered in
More information1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing
The Keri NXT-6RK is a keypad reader typically used for card + PIN dual verification applications. It transmits keypad data in either 8-bit burst (default) or 26-bit Wiegand formats and can be used as a
More informationUSB 2.0 CAT5E/6/7 EXTENDER
USER MANUAL IC402A-R2 USB 2.0 CAT5E/6/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM + + + + Mode Config Power Link Host Activity Power Link Host Activity TABLE OF CONTENTS PRODUCT OPERATION AND STORAGE... 3
More informationEC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method
Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available
More informationAdapter Kit - QSI Electronics to G2 Meter Installation Instructions
Adapter Kit - QSI Electronics to G2 Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More information845G. Description. Features. Specifications
845G The 845G is a heavy duty NEMA Type 4 and 13 single turn absolute encoder that digitizes shaft position. The absolute encoder has a unique digital output for each shaft position. The use of absolute
More informationiclass INSTALLATION GUIDE
iclass INSTALLATION GUIDE 13.56 MHz Contactless Smart Card Readers with Keypad RK40 RWK400 RPK40 iclass RK40, RWK400, RPK40 Parts List PARTS 1 - iclass Reader 1 - Installation Manual 2-3 5 mm x.6 pitch
More informationAdapter Kit - QSI Electronics to TM Meter Installation Instructions
Adapter Kit - QSI Electronics to TM Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics
More informationIn-Sight 7010C/7200C/7400C
The following sections list general specifications for the In-Sight vision system. Vision System Specifications Table 3-1: Vision System Specifications Specifications Minimum Firmware Requirement Job/Program
More informationEthernet Test Access Panel (ETAP) User Manual
Ethernet Test Access Panel (ETAP) User Manual Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................
More informationInstallation Instructions RF5010 and RF5210
Installation Instructions RF5010 and RF5210 HES, Inc. 2260 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards
More informationEXTENDER ELE8082. INSTALLATION Manual. Made in Taiwan
EXTENDER ELE8082 INSTALLATION Manual Made in Taiwan Safety and Notice The ELE8082 HDMI EXTENDER has been tested for conformance to safety regulations and requirements, and has been certified for international
More informationLong Reach. PoE over Coaxial / UTP. Extender Kit. LRP-101C-KIT and LRP-101U-KIT. User s Manual
Long Reach PoE over Coaxial / UTP Extender Kit LRP-101C-KIT and LRP-101U-KIT User s Manual Trademarks Copyright PLANET Technology Corp. 2015. Contents are subject to revision without prior notice. PLANET
More informationDL-HD2100 Quick Install Guide
DL-HD2100 Quick Install Guide This guide is for quick installation only. For complete owners manual go to www.libav.com or use a QR reader to access the manual via QR code below. Scan QR Code with your
More informationIndustrial 8-Port 10/100TX 802.3at PoE+ + 2-Port Gigabit TP/SFP Combo Ethernet Switch IFGS-1022HPT. User s Manual
Industrial 8-Port 10/100TX 802.3at PoE+ + 2-Port Gigabit TP/SFP Combo Ethernet Switch IFGS-1022HPT User s Manual Table of Contents 1. Package Contents... 3 2. Hardware Introduction... 4 2.1 Physical Dimensions...
More information5/8-Port 10/100/1000Mbps. Industrial Gigabit Ethernet Switch IGS-501 / IGS-801 / IGS-501T / IGS-801T. User's Manual
5/8-Port 10/100/1000Mbps Industrial Gigabit Ethernet Switch IGS-501 / IGS-801 / IGS-501T / IGS-801T User's Manual Trademarks Copyright PLANET Technology Corp. 2009. Contents subject to revision without
More informationFE8171V. 3MP 360 Panoramic View Vandal-proof
FE8171V 3MP 360 Panoramic View Vandal-proof Warning Before Installation English Power off the Network Camera as soon as smoke or unusual odors are detected. Refer to your user's manual for the operating
More informationRING LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED
R80 Series RING LIGHT product introduction The all metal construction of the Series of lights provides a small particle resistant and all around durable light. Its simple plug and play 5 Pin M12 connector
More informationQuick Start Guide. Installation. User s Manual 1
Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Installation
More informationIndustrial Ultra Power over Ethernet Splitter IPOE-171S
Industrial Ultra Power over Ethernet Splitter IPOE-171S User s Manual Table of Contents 1. Package Contents... 3 2. Product Features... 4 3. Product Specifications... 5 4. Hardware Introduction... 8 4.1
More informationF1000 User's Manual. (Version: V1.01)
(Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...
More information5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual
5 10/100TX w/ 4 PoE Injector Industrial Switch User Manual V1.01 Nov-2010 CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the
More information9/27/04 cci Cablecom Inc. 1
cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local
More information4. We recommend that you install the ievo reader at the DDA height of approximately 1 metre. This will be the perfect height for finger placement.
WELCOME ievo would like to thank you for purchasing our product. This manual is designed to make your installation of our superior biometric reader quick, easy and efficient. Please ensure you check all
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables 0 Cable Spools Unshielded
More informationCAT EXT-CAT USER MANUAL.
CAT5 7500 EXT-CAT5-7500 USER MANUAL www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (88) 772-900 (800) 545-6900 Fax (88) 772-920 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru
More informationWELCOME. Network: Only use Shielded CAT5 cable for network communication.
WELCOME ievo would like to thank you for purchasing our product. This manual is designed to make your installation of our superior biometric reader quick, easy and efficient. Please ensure you check all
More informationNS1 Connection Unit Guide
PURPOSE AND APPLICATION Connection Unit Guide The connection unit is an installation friendly device, which makes it possible to use all features from a central unit. The CU can also be used to connect
More informationWarning Before Installation. Package Contents EN - 1. Refer to your user s manual for the operating temperature.
5000020G Warning Before Installation English Power off the Network Camera as soon as smoke or unusual odors are detected. Do not place the Network Camera on unsteady surfaces. Do not insert sharp or tiny
More informationCat.6/5e UTP Patch Panels with 45 Jack
Cat.6/5e UTP Patch Panels with 45 Jack Index TOOL KITS TOOL WIRING CONNECTORS LAN/DATACOMM INSTRUMENT MISCELLANEOUS POWER TOOLS FIBER OPTICS MAGNIFICATION & Our Cat.6/5e patch panels are used for high
More informationSP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:
DOC0067 Issue 1.2 Reader Wiring InSTRUCTIONS SP1 MP1 WP2 WP1 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes: MP1-EM1 MP1-HT1 MP1-DP1 WP1-EM1 WP1-HT1
More informationSC500/SC500P. Installation Note
SC500/SC500P Installation Note 81473 007 EN SC500P Sc500 SC500 Smart Card Reader General The SC500 is a reader that reads data from Mifare cards. The default configuration reads the chip serial number
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing
More information4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual
4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables Cable Spools Unshielded Twisted
More informationSERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS
HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS Resolution up to 50.000 pulses per turn External diameter 58 mm Hollow shaft from Ø 10 to 14 mm Protection class IP67 according
More informationLNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.
LNP-0500-24 series 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input User Manual FCC Warning This Equipment has been tested and found to comply with
More informationCAT U S E R M A N U A L
CAT5 7500 U S E R M A N U A L www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 884-6294 (800) 545-6900 Fax (818) 884-3108 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More informationCardax FT Controller 3000
Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any
More informationNote: the wiring of the dead-man buttons has been changed since October 2001.
UniOP epalm10 The epalm10 is a state-of-the-art handheld HMI device with a graphic display and a keypad. The rugged polyamide enclosure offers a high level of shock and environmental resistance making
More informationMifare ID Reader. with selectable outputs
714-52 Mifare ID Reader with selectable outputs The 714-52 OEM proximity reader consists of three parts: a potted unit containing the electronics and antenna, a front cover, and an optional spacer plate.
More informationUSB 3.1 CAT6A/7 EXTENDER
USER MANUAL ICU504A USB 3.1 CAT6A/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM Power Mode Config Status Link Video USB 2 USB 3 Power Mode Config Status Link Video USB 2 USB 3 TABLE OF CONTENTS PRODUCT OPERATION
More informationOperation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller
Operation Manual Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller KEYKING GROUP Index Chapter 1: Summay...3 1.1 Outline...3
More informationLP-4CEUSXX Cat 5e Unshielded U/UTP Patch Cords
Cabling - Copper Solutions LP-4CEUSXX Cat 5e Unshielded U/UTP Patch Cords LP4CEUSXX_SS_ENB01W Features Unshielded snagless U/UTP Patch Cords. UL, CSA approved. ETL verified. Cat 5e patch cords are backward
More information8 10/100/1000T Industrial Switch. User Manual MS655208(X)
8 10/100/1000T Industrial Switch User Manual MS655208(X) Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel... 5 Top View...
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationLeuze electronic. Dimensioned drawing. Electrical connection. Accessories
2D-code hand-held scanner Dimensioned drawing 4-14 V DC We reserve the right to make changes BP_IT4600_4800_GB.fm Part No. 501 06667! Hand-held scanner for Data-Matrix Codes and Bar Codes! Large reading
More informationInstallation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B
Installation Manual - 5365-902 Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 1 of 7 MiniProx Reader
More informationGigaSwitch 8. User Guide
GigaSwitch 8 User Guide GigaSwitch 8 User Guide Document lu_01_00016_4_man Copyright 2003-2011. All rights reserved. No part of this documentation may be reproduced or transmitted in any form or by any
More informationIEI emerge MicroNode Install and Setup Guide. Contents
IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationGV-RK1352 and GV-R1352 Card Reader
GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured
More informationQuick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER
MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING
More informationUSB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide
USB 2.0 RG2304GE-LAN 4-Port USB 2.0 Gigabit Ethernet LAN Extender System User Guide Thank you for purchasing the USB 2.0 RG2304GE-LAN. Please read this guide thoroughly. This document applies to Part Numbers:
More information7I44 MANUAL 8 CHANNEL RS-422 INTERFACE
7I44 MANUAL 8 CHANNEL RS-422 INTERFACE V1.1 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................
More informationDVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8
DVI KVM Extra Long Range Extender Over One CAT5 EXT-DVIKVM-ELR User Manual Release A8 Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all
More informationUSB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide
USB 3-2-1 Raven 3104 4-Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3104. Please read this guide thoroughly. This document applies
More informationHDMI CAT5 Extender Over Single cable Series ITEM NO.: HE01ST, HE01SR, HE01SLR, HE01SER
HDMI CAT5 Extender Over Single cable Series ITEM NO.: HE01ST, HE01SR, HE01SLR, HE01SER The HDMI CAT5 Extender is using only one cost effective CAT5E/6 cable to extend your HDTV display up to 70 meters
More informationEXTENDER ELE8081. INSTALLATION Manual. Made in Taiwan
EXTENDER ELE8081 INSTALLATION Manual Made in Taiwan Safety and Notice The ELE8081 HDMI EXTENDER has been tested for conformance to safety regulations and requirements, and has been certified for international
More informationSoundwebTM. Installation Guide
105 SoundwebTM Soundweb TM 9000 Installation Guide Soundweb TM Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards
More informationIEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual
Lantech IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
More informationSoundwebTM. Installation Guide
111 SoundwebTM Soundweb TM 9010 Installation Guide Soundweb TM Regulatory Information v1.0 PW/JMK 21st March 1999 An example of this equipment has been tested and found to comply with the following European
More informationInstallation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers
Roger Access Control System Installation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers Firmware version: 1.18.6 or newer Document version: Rev. G 2016 ROGER sp.
More informationHDBaseT EXTENDER B-520-TX-230-IR B-520-TX-330-IR INSTALLATION MANUAL
HDBaseT EXTENDER B-50-TX-30-IR B-50-TX-330-IR INSTALLATI MANUAL IMPORTANT SAFETY INSTRUCTIS To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this manual. Keep
More informationBA/BS4S Temperature Sensor Installation & Operating Instructions
Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.
More informationSENC 150 REFERENCE MANUAL
SENC 50 REFERENCE MANUAL SENC 50 Table of Contents / Warnings Page Introduction / Supplied items... 4 2 Preparing the mounting / Mounting information... 5 3 Encoder dimensions... 8 4 Backup spar dimensions...
More informationApplication Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)
Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection
More informationR SERIES INSTALLATION GUIDE
R SERIES INSTALLATION GUIDE Welcome to your smartest install yet. Things you should know Latch R is a proximity reader, keypad, and wireless entry system, that can be operated as a standalone device or
More information10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual
10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1
More informationUSB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by
USB Ranger 2212 Cat 5 USB 2.0 Extender with Remote Power User Guide Powered by Thank you for purchasing the USB Ranger 2212. Please read this guide thoroughly. This document applies to Part Numbers: 00-00252,
More informationAdapter Kit - QSI Electronics to G-Series Meter Installation Instructions
Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics
More information