1 4-iber PO System 10/40/100 GbE igration Solution RG Series Ordering Guide irst Edition

2

3 Table of Contents 4-iber Trunking Soluction Overview... 3 RG 4-iber Interconnect System 10 Gigabit Interconnect Introduction...4 -iber LC A-B Patch Cord...4 1x1 LC-PO, Straight A-A/B-B...4 PO Trunk, Polarity A...4 1x1 LC-PO, lipped A-B/B-A...4 1,, and 4 RU Chassis (not shown in system diagram)...4 Ordering Information... 5 Specifications... 5 HD 10 Gigabit Interconnect Introduction iber PO Patch Cord, Polarity A...6 x6 PO...6 PO Trunk, Polarity A...6 1,, and 4 RU Chassis (not shown in system diagram)...6 Ordering Information... 7 Specifications iber HD Array... 8 x6 PO... 8 PO Trunk, Polarity A iber PO Patch Cord, Polarity A ,, and 4 RU Chassis (not shown in system diagram)... 8 Ordering Information...9 Specifications Gigabit Interconnect Introduction iber PO Patch Cord, Polarity A ` x6 PO PO Trunk, Polarity A ,, and 4 RU Chassis (not shown in system diagram) Ordering Information...11 Specifications x3 PO Array...1 PO Adapter odule...1 PO Trunk, Polarity A...1 1,, and 4 RU Chassis (not shown in system diagram)...1 Ordering Information...13 Specifications ax: AE 1/13

4 100 Gigabit Interconnect Introduction...14 PO Patch Cord, Polarity A...14 PO Adapter odule...14 PO Patch Cord, Polarity B ,, and 4 RU Chassis (not shown in system diagram)...14 Ordering Information Specifications RG Cross-Connect System 10 Gigabit Cross-Connect Introduction iber LC A-B-Patch Cord x1 LC-PO, Straight A-A/B-B PO Trunk, Polarity A x1 LC-PO, lipped A-B/B-A ,, and 4 RU Chassis (not shown in system diagram) Ordering Information Specifications HD 10/40 Gigabit Cross-Connect Introduction iber HD Array x6 PO PO Trunk, Polarity A iber PO Patch Cord, Polarity B iber PO Patch Cord, Polarity A ,, and 4 RU Chassis (not shown in system diagram) Ordering Information Specifications Gigabit Cross-Connect Introduction iber PO Patch Cord, Polarity A...0 x6 PO...0 PO Trunk, Polarity A iber PO Patch Cord, Polarity B...0 1,, and 4 RU Chassis (not shown in system diagram)...0 Ordering Information... 1 Specifications Gigabit Cross-Connect Introduction... PO Patch Cord, Polarity A... PO Adapter odule... PO Trunk, Polarity A... PO Patch Cord, Polarity B... 1,, and 4 RU Chassis (not shown in system diagram)... Ordering Information... 3 Specifications ax: AE 1/13

5 RG 4-iber System Overview 4-iber Trunking Solutions Introduction Bandwidth and storage demand is expanding at a breathtaking rate. The environment is rapidly evolving. The impact on data center design and management is profound. Networks will migrate from 10 to 40 to 100 Gigabit/second Ethernet speeds dynamically, and data center managers and designers need to be able to manage this migration to maximize efficiency and responsiveness while minimizing cost. This dynamic migration demands a simple yet robust migration pathway, and successful migration starts with a simple yet robust plan. This guide presents just such a concise and manageable plan to allow migration of infrastructure, whether it be core switching, aggregation, end of row, top of rack or hybrid network architectures. Centered around 4-fiber trunks and optical connectivity, this roadmap provides the following advantages: A single trunking format that can be replicated and upgraded simply and flexibly Unified solutions for 10, 40 and 100 GbE applications Pre-engineered paths and polarity Higher fiber utilization versus 1 fiber systems ewer trunks ewer connections ewer components Standardized practices for design, installation, documentation and troubleshooting Component and trunk re-use inimized waste of space, time and money The following pages provide this plan -- designs and products for each step of your network s evolution to 100 GbE, allowing your data center strategy to become a dynamic business advantage. 10G LC Duplex Patch 4 iber Trunk 1 x iber LC Duplex Patch 40G 3 x 1 iber Patch Cable 4 iber Trunk 3 x 1 iber Patch Cable 100G 1 x 4 iber Patch Cable 4 iber Trunk 1 x 4 iber Patch Cable Page ax: AE 1/13

6 RG 4-iber 10 Gigabit Interconnect Introduction 10 GbE Interconnect The 10 Gigabit Interconnect Solution, like all of the planned migration designs, employs a 4-fiber optical trunk with a single PO-type connector at each end. A trunk interfaces with the rear of a 4-fiber RG cassette that breaks out the trunk fibers into twelve duplex LC connections at the front, supporting 4 fibers per cassette. This cassette resides in a time-proven RG chassis which provides cable management and protection for both the POs at the rear and LC cords at the front. RG enclosures are stackable and available in 1,, and 4 RU versions and support up to 36 duplex LCs (7 fibers) per rack unit. They can be populated all at once, or added to or upgraded a cassette at a time in the future. The RG enclosure also supports high density 10 Gigabit cassettes, as well as 40 and 100 GbE versions, allowing an upgrade path by changing the cassette at the front and using existing and additional 4-fiber trunks at the rear. 3 4-iber PO Trunk A-Polarity (Type 4-iber 4 4-iber L L L L L L L L L L L L 1 LC-Duplex A-B Patch 1 LC-Duplex A-B Patch LC-PO 4-iber Trunk RG 1 RU Chassis RG RU Chassis RG 4 RU Chassis Page ax: AE 1/13

7 RG 4-iber 10 Gigabit Interconnect ORDERING INORATION 10 Gigabit LC-PO Number Component Part Number 1 -iber LC A-B Patch Cord PAT-LCLC-R40Cxxx 1x1 LC-PO, Straight A-A/B-B RG-4POTD3 3 4-iber Trunk, Polarity A PT-CC40xxx-NN 4 1x1 LC-PO, lipped A-B/B-A RG-4POTD4 N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters 10 GbE Interconnect Specifications POptimate Performance: Traceable: Standard iber Path: 4-iber Trunk: Pinned s: s used in Pairs: lexible: s are factory assembled and tested, 0.35 db maximum loss Each cassette is uniquely identified and linked to factory measurement data Compatible with TIA 568-C.0- draft standard for polarity method A iber path supports 4-fiber deployment PO alignment pins are maintained inside the cassette, reducing risk of damage during installation and use Assures proper fiber map, polarity and location of PO alignment pins Chassis enables superior cable management and can be stacked in a standard 19-inch rack or cabinet Page ax: AE 1/13

8 RG 4-iber HD 10 Gigabit Interconnect Introduction RG High Density 10 Gigabit iber s also utilize 4-fiber PO trunks and support connection from 40 Gigabit switch ports that have been remotely enabled as four 10 Gigabit independent paths. PO based QSP ports at the switch interface with a cassette at one end of the trunk, and a break-out cassette divides these signals into duplex LC pairs at the other end. HD 10 GbE Interconnect PO cassettes have two 4-fiber PO connectors at the rear and six 8-fiber POs at the front. Each cassette supports distribution of six 40 Gigabit Ethernet paths, each containing four duplex 10 Gigabit links. These cassettes are connected via standard 4-fiber PO trunks to a pair of two x1 LC duplex cassettes at the other end of the trunk. This pair of cassettes maintains fiber paths and polarity and provides proper fiber mapping from transmit at one end to receive at the other over a total of twenty-four 10 Gigabit paths. All cassettes are compatible with RG chassis, frames and hardware, and feature a simple, yet highly effective, cable management system. s are 1/ RU high and snap easily into existing or newly installed RG chassis, and can be replaced by 40 and 100 GbE cassettes in the future. 3 4-iber 4-iber PO Trunk A-Polarity (Type A) 4 4-iber L L L L L L iber PO Patch Cord A-Polarity (Type A) -iber LC A-B Patch Cord LC-PO PO 4-iber Trunk RG 1 RU Chassis RG RU Chassis RG 4 RU Chassis Page ax: AE 1/13

9 RG 4-iber HD 10 Gigabit Interconnect ORDERING INORATION High Density LC to PO 10 Gigabit s Number Component Part Number 1 1-iber PO Patch Cord, Polarity A (Type A) PT-NCNCJ40xxx-NN x6 PO RG-48POT 3 4-iber Trunk, Polarity A (Type A) PT-CC40xxx-NN 4 1x1 LC-PO, 10G HD RG-4POTD5 5 -iber LC A-B Patch Cord PAT-LCLC-R40Cxxx N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters Specifications POptimate Performance: Traceable: Standard iber Path: 4-iber Trunk: Pinned s: s Used in Pairs: lexible: Cassetttes are factory measured maximum 0.35 db loss Each cassette is uniquely identified and linked to factory measurement data Compatible with TIA 568-C.0- draft standard for polarity method A trunks for 40 GbE iber path supports dual-fiber 10 Gigabit deployment via 40 Gigabit equipment connections (4x10 Gbe paths per QSP port) PO alignment pins are maintained inside the cassette, reducing risk of damage Assures proper fiber map, polarity and location of PO alignment pins RG enables superior cable management regardless of cassette type HD 10 GbE Interconnect Page ax: AE 1/13

10 RG 4-iber HD 10 Gigabit Interconnect Introduction RG High Density 10 Gigabit iber s also utilize 4-fiber PO trunks and support connection from 40 Gigabit switch ports that have been remotely enabled as four 10 Gigabit independent paths. PO based QSP ports at the switch port interfaces with a cassette at one end of the trunk and as an option, can employ a break-out array divides these signals into duplex LC pairs at the other end. HD 10 GbE Interconnect PO cassettes have two 4-fiber PO connectors at the rear and six 8-fiber POs at the front. Each cassette supports distribution of six 40 Gigabit Ethernet paths, each containing four duplex 10 Gigabit links. These cassettes are connected via standard 4-fiber PO trunks to a pair of x1 LC duplex cassettes at the other end of the trunk. This pair of cassettes maintains fiber paths and polarity and provides proper fiber mapping from transmit at one end to receive at the other over a total of twenty-four 10 Gigabit paths. All cassettes are compatible with RG chassis, frames and hardware, and feature a simple, yet highly effective, cable management system. s can snap easily into existing or newly installed RG chassis and can be replaced by 40 and 100 GbE cassettes in the future. 3 4-iber 4-iber PO Trunk A-Polarity (Type A) 4-iber 1 8-iber High Density Array 4 1-iber PO Patch Cord A-Polarity (Type A) 8-iber HD Array PO 4-iber Trunk, RG 1 RU Chassis RG RU Chassis RG 4 RUChassis Page ax: AE 1/13

11 RG 4-iber HD 10 Gigabit Interconnect ORDERING INORATION HD 10 Gigabit PO-PO s Number Component Part Number Specifications POptimate Performance: Traceable: Standard iber Path: 4-iber Trunk: Pinned s: s used in Pairs: 1 8-iber High Density Array PH-NCLCJ40xxx-NS x6 PO RG-48POT 3 4-iber Trunk, Polarity A (Type A) PT-CC40xxx-NN 4 1-iber PO Patch Cord, Polarity A (Type A) PT-NCNCJ40xxx-NN N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters actory measured maximum 0.35 db loss per cassette Each cassette is uniquely identified and linked to factory measurement data Compatible with TIA 568-C.0- draft standard for polarity method A trunks for 40 GbE iber path supports dual-fiber 10 Gigabit deployment via 40 Gigabit equipment connections (4x10 GbE paths per QSP port) PO alignment pins are maintained inside the cassette, reducing risk of damage Assures proper fiber map, polarity and location of PO alignment pins HD 10 GbE Interconnect lexible: Chassis enables superior cable management regardless of cassette type Page ax: AE 1/13

12 RG 4-iber 40 Gigabit Interconnect Introduction or 40 GbE applications RG 40 Gigabit iber s provide connection from two standard 4-fiber PO trunks with 4-fiber dual row connectors to six, single row 8-fiber PO connectors. Each trunk supports three 8-fiber 40 Gigabit links, utilizing all 4 fibers of the trunk without abandoning any fibers. Each cassette supports distribution of six 40 Gigabit Ethernet links. When used in pairs they provide proper fiber mapping and polarity from transmit at one end of the link to receive at the other. 40 GbE Interconnect s are compatible with RG chassis, frames and hardware, and feature a simple, yet highly effective, cable management system. s snap easily into existing or newly installed RG chassis. All 10, 40 and 100 GbE cassettes can reside within the same RG chassis and frame and be changed/upgraded individually as needed. 4-iber 3 4-iber PO Trunk A-Polarity (Type A) 4-iber 4-iber 1 1-iber PO Patch Cord A-Polarity (Type A) 1-iber PO Patch Cord A-Polarity (Type A) 1 PO 4-iber Trunk, RG 1 RU Chassis RG RU Chassis RG 4 RU Chassis Page ax: AE 1/13

13 RG 4-iber 40 Gigabit Interconnect ORDERING INORATION 40 Gigabit PO-PO s Number Component Part Number Specifications POptimate Performance: Traceable: Standard iber Path: 4-iber Trunk: Pinned s: s used in Pairs: lexible: 1 1-iber PO Patch Cord, Polarity A (Type A) PT-NCNCJ40xxx-NN x6 PO RG-48POT 3 4-iber Trunk, Polarity A (Type A) PT-CC4Oxxx-NN N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters actory assembled and tested, 0.35 db maximum per cassette Each cassette is uniquely identified and linked to factory measurement data Compatible with TIA 568-C.0- draft standard for polarity method A" trunks iber path supports 4-fiber deployment and 40 Gigabit equipment connections. Each 4-fiber trunk supports three 8-fiber pathways without abandoning any trunk fibers PO alignment pins are maintained inside the cassette, reducing risk of damage Assures proper fiber map, polarity and location of PO alignment pins System supports use of arrays or cassettes and patchcords at either end of the trunk 40 GbE Interconnect Page ax: AE 1/13

14 RG 4-iber 40 Gigabit Interconnect Introduction In an optional configuration for 40 Gigabit applications, the RG 40 Gigabit iber Adapter odule provides connection from six standard 4-fiber PO trunks with 4-fiber, dual row connectors to PO arrays. Each array breaks out from the 4-fiber connection to three 8-fiber single row 40 GbE channels. Each trunk supports three 8-fiber 40 Gigabit links, utilizing all 4 fibers of the trunk without abandoning any fibers. 40 GbE Interconnect Adapter modules are compatible with RG chassis, frames and hardware, and feature a simple, yet highly effective, cable management system. Adapter modules slide easily into existing or newly installed RG chassis. Adaptor modules and 10, 40 and 100 GbE cassettes can reside within the same RG chassis and frame and be changed/upgraded individually as needed. 4-iber Adapter odule 3 4-iber PO Trunk A-Polarity (Type A) 4-iber Adapter odule 1 1 1x3 PO Array 1x3 PO Array 1x3 PO Array PO Adapter odule 4-iber Trunk RG 1 RU Chassis RG RU Chassis RG 4 RI Chassis Page ax: AE 1/13

15 RG 4-iber 40 Gigabit Interconnect ORDERING INORATION 40 Gigabit PO-PO s Number Component Part Number Specifications POptimate Performance: Traceable: Standard iber Path: 4-iber Trunk: Arrays or s used in Pairs: lexible: 1 1x3 PO Array PG-1CNC40xxx-NS PO Adapter odule RG-7ADPP 3 4-iber Trunk, Polarity A (Type A) PT-CC40xxx-NN N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters Compatible with POptimate components Each array is uniquely identified and linked to factory measurement data Compatible with TIA 568-C.0- draft standard for polarity method A" trunks iber path supports 4-fiber deployment and 40 Gigabit equipment connections. Each 4-fiber trunk supports three 8-iber pathways without abandoning any trunk fibers Assures proper fiber map, polarity and location of PO alignment pins System supports use of arrays or cassettes and patch cords at either end of the trunk 40 GbE Interconnect Page ax: AE 1/13

16 RG 4-iber 100 Gigabit Interconnect Introduction RG 100 Gigabit iber Adapter odules provide connection from six PO trunks with 4-fiber, dual row connectors to six 4-fiber PO equipment or patch cords. Each adapter module supports distribution of six 100 Gigabit Ethernet links. When used in pairs with 4-fiber PO patch cord pairs they provide proper fiber mapping from transmit at one end to receive at the other of the link. Adapter modules are compatible with RG chassis, frames and hardware, and feature a simple, yet highly effective, cable management system. odules simply snap into existing or newly installed RG chassis. Each unit is fully assembled at the factory and can reside in a chassis with 10, High Density 10, 40, and 100 GbE cassettes. Chassis are available in 1,, and 4 rack unit (RU) versions. 100 GbE Interconnect 4-iber Adapter odule 4-iber PO Patch Cord A-Polarity (Type A) 3 4-iber PO Trunk A-Polarity (Type A) iber Adapter odule 4-iber PO Patch Cord B-Polarity (Type B) PO Adapter odule 4-iber Trunk RG 1 RU Chassis RG RU Chassis RG 4 RU Chassis Page ax: AE 1/13

17 RG 4-iber 100 Gigabit Interconnect ORDERING INORATION 100 Gigabit PO to PO Adapter odule Number Component Part Number 1 4-iber PO Patch Cord, Polarity A (Type A) PT-1CC40xxx-NN PO Adapter odule RG-7ADPP 3 4-iber Trunk, Polarity A (Type A) PT-CC40xxx-NN 4 4-iber PO Patch Cord, Polarity B (Type B) P-1CC40xxx-NN N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters Specifications POptimate Performance: Standard iber Path: 4-iber Trunk: Patch Cords used in Pairs: Compatible with POptimate trunks and arrays Compatible with TIA 568-C.0- draft standard for polarity method A" trunks Up to six 4-fiber PO trunks per module Assures proper fiber map, polarity and location of PO alignment pins 100 GbE Interconnect Page ax: AE 1/13

18 RG 4-iber 10 Gigabit Cross-Connect Introduction The 10 Gigabit Cross-Connect Solution, like all of the planned migration designs, begins with a 4-fiber optical trunk with a single PO-type connector at each end. One trunk interfaces with the rear of an RG cassette that breaks out the trunk fibers into twelve duplex LC connections at the front, supporting 4 fibers per cassette. This cassette resides in a highly efficient RG encolsure which provides superior cable management for both the POs at the rear and LC cords at the front. RG enclosures are stackable and available in 1, and 4 RU versions. Each support up to 36 duplex LCs (7) fibers per rack unit. They can be populated all at once, or added to or upgraded a cassette at a time in the future. The RG chassis also supports high density 10 Gigabit cassettes, as well as 40 and 100 GbE versions, allowing an upgrade path by changing the cassette at the front and using existing and additional 4-fiber trunks at the rear. 10 GbE Cross-Connect Chassis can be cascaded to form a half or full cross-connect layout. Cross-connection can be implemented via LCs to maintain single channel flexibility. (Note: Some cross-connect architectures are treated as engineered links, and available power budget must be verified.) 3 4-iber Type A Trunk 4-iber Type A Trunk A-Polarity (Type A) A-Polarity (Type A) 4-iber L LL LC L L L L L L 4-iber LC L L L L L L 3 4-iber 4 4 LC L L L L L L 4-iber LC L L L L L L 1 LC Duplex A-B Patch Cord 1 1 LC Duplex A-B Patch Cord LC Duplex A-B Patch Cord LC-PO 4-iber Trunk RG 1 RU Chassis RG RU Chassis RG 4 RU Chassis Page ax: AE 1/13

19 RG 4-iber 10 Gigabit Cross-Connect ORDERING INORATION 10 Gigabit LC to LC Cross-Connect s Number Component Part Number 1 -iber LC A-B Patch Cord PAT-LCLC-R40Cxxx 1x1 LC-PO, Straight A-A/B-B RG-4POTD3 3 4-iber Trunk, Polarity A (Type A) PT-CC40xxx-NN 4 1x1 LC-PO, lipped A-B/B-A RG-4POTD4 N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters Specifications POptimate Performance: Traceable: Standard iber Path: 4-iber Trunk: Pinned s: s used in Pairs: lexible: actory measured maximum measured 0.35 db loss per cassette Each cassette is uniquely identified and linked to factory measurement data Compatible with TIA 568-C.0- draft standard for polarity method A iber path supports 4-fiber deployment PO alignment pins are maintained inside the cassette, reducing risk of damage Assures proper fiber map, polarity and location of PO alignment pins Chassis enables superior cable management and can be stacked in a standard 19-inch rack or cabinet Page ax: AE 1/13

20 RG 4-iber HD 10/40 Gigabit Cross-Connect Introduction RG High Density 10 Gigabit iber s also utilize 4-fiber PO trunks and support connection from 40 GbEswitch ports that have been remotely enabled as four 10 GbE independent paths. PO based QSP ports at the switch connection interface with a cassette at one end of the trunk, and a break-out cassette divides these signals into duplex LC pairs at the other end. Alternately, a fiber array can accumulate/break out the fiber paths immediately at the switch. Chassis and cassettes can be cascaded to for half or full cross-connect architectures. Cross connection can be implemented via LCs to maintain single channel flexibility (Note: Some crossconnect architectures are treated as engineered links, and available power budget must be verified.) HD 10/40 GbE Cross-Connect PO cassettes have two 4-fiber PO connectors at the rear and six 8-fiber POs at the front. Each cassette supports the distribution of six 40 Gigabit Ethernet paths, each containing four duplex 10 Gigabit links. These cassettes are connected via standard 4-fiber PO trunks to x1 LC duplex cassettes at the other end of the trunk and in the cross-connect frame. This pair of cassettes maintains fiber paths and polarity and provides proper fiber mapping from transmit at one end to receive at the other. All cassettes are compatible with RG chassis, frames and hardware, and feature a simple, yet highly effective, cable management system. s simply snap into existing or newly installed RG chassis, and can be replaced by 40 and 100 GbE cassettes in the future. 3 4-iber PO Trunk A-Polarity (Type A) 4-iber 1 8-iber High Density Array Duplex LC x 4 4-iber 4-iber PO Trunk A-Polarity (Type A) 4-iber 4-iber iber PO Patch 1-iber PO Cord A-Polarity Patch Cord (Type A) 3 8 iber HD Array PO 4-iberTrunk RG 1 RU Chassis RG RU Chassis RG 4 RU Chassis Page ax: AE 1/13

21 RG 4-iber HD 10/40 Gigabit Cross-Connect ORDERING INORATION HD 10/40 Gigabit LC-PO Cross-Connect s Number Component Part Number 1 8-iber High Density Array PH-NCLCJ40xxx-NS x6 PO RG-48POT 3 4-iber Trunk, Polarity A (Type A) PT-CC40xxx-NN 4 1-iber PO Patch Cord, Polarity B (Type B) P-NCNCJ40xxx-NN 5 1-iber PO Patch Cord, Polarity A (Type A) PT-NCNCJ40xxx-NN N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters Specifications POptimate Performance: Traceable: Standard iber Path: 4-iber Trunk: Pinned s: s used in Pairs: lexible: actory measured maximum measured 0.35 db loss per cassette Each cassette is uniquely identified and linked to factory measurement data Compatible with TIA 568-C.0- draft standard for polarity method "A" (for 40 Gigabit Ethernet) iber path supports dual-fiber 10 Gigabit deployment via 40 Gigabit equipment connections (4x10 GbE paths per QSP port) PO alignment pins are maintained inside the cassette, reducing risk of damage Assures proper fiber map, polarity and location of PO alignment pins Chassis enables superior cable management and can be stacked in a standard 19-inch rack or cabinet HD 10/40 GbE Cross-Connect Page ax: AE 1/13

22 RG 4-iber 40 Gigabit Cross-Connect Introduction or 40 GbE applications RG 40 Gigabit iber s provide connection from two standard 4-fiber PO trunks with 4-fiber dual row connectors to six single row 8-fiber PO connectors. Each trunk supports three 8-fiber 40 Gigabit links, utilizing all 4 fibers of the trunk without abandoning any fibers. Each cassette supports distribution of six 40 Gigabit Ethernet links. (Note: 1x3 cassettes are also available.) When used in pairs they provide proper fiber mapping and polarity from transmit at one end of the link to receive at the other. (Note: Some cross-connect architectures are treated as engineered links, and available power budget must be verified.) s are compatible with RG chassis, frames and hardware, and feature a simple, yet highly effective cable management system. s simply snap into existing or newly installed RG chassis. 10, 40 and 100 GbE cassettes can reside within the same RG chassis and can be changed/upgraded as needed. 40 GbE Cross-Connect 4-iber iber PO Trunk 1-iber PO Patch Cord B-Polarity (Type B) 4-iber 4-iber PO Trunk A-Polarity (Type A) A-Polarity (Type A) 1-iber PO Patch Cord A-Polarity (Type A) 4-iber iber 1-iber PO Patch Cord A-Polarity (Type A) 1 PO 4-iberTrunk RG 1 RU Chassis RG RU Chassis RG 4 RU Chassis Page ax: AE 1/13

23 RG 4-iber 40 Gigabit Cross-Connect ORDERING INORATION 40 Gigabit PO to PO Cross-Connect s Number Component Part Number 1 1-iber PO Patch Cord, Polarity A (Type A) PT-NCNCJ40xxx-NN x6 PO RG-48POT 3 4-iber Trunk, Polarity A (Type A) PT-CC40xxx-NN 4 1-iber PO Patch Cord, Polarity B (Type B) P-NCNCJ40xxx-NN N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters Specifications POptimate Performance: Traceable: Standard iber Path: 4-iber Trunk: Pinned s: s used in Pairs: lexible: actory assembled and tested, 0.35 db maximum per cassette Each cassette is uniquely identified and linked to factory measurement data Compatible with TIA 568-C.0- draft standard for polarity method "A" trunks iber path supports 4-fiber deployment and 40 GbE equipment connections. Each 4-fiber trunk supports three 8-iber pathways without abandoning any trunk fibers. PO alignment pins are maintained inside the cassette reducing risk of damage Assures proper fiber map, polarity and location of PO alignment pins System supports use of arrays or cassettes and patchcords at either end of the trunk. Arrays can be used as an alternate to cassettes where preferred. 40 GbE Cross-Connect Page ax: AE 1/13

24 RG 4-iber 100 Gigabit Cross-Connect Introduction RG 100 Gigabit iber Adapter odules provide connection from six PO trunks with 4-fiber, dual row connectors to six 4-fiber PO equipment or patch cords. Each module supports the distribution of six 100 Gigabit Ethernet links. When used in pairs with 4-fiber PO patch cord pairs they provide proper fiber mapping from transmit at one end to receive at the other end of the link. Adapter modules an be cascaded to provide half or full Cross-Connect architectures. (Note: Some cross-connect architectures are treated as engineered links, and available power budget must be verified.) Adapter modules are compatible with RG chassis, frames and hardware, and feature a simple, yet highly effective, cable management system. odules or cassettes simply snap into existing or newly installed RG chassis. Each unit is fully assembled at the factory and can reside in a chassis with along with 10, High Density 10, 40 and 100 GbE cassettes. Chassis are available in 1, and 4 rack unit (RU) versions. 3 4-iber PO Trunk 3 4-iber PO Trunk A-Polarity (Type A) A-Polarity (Type A) 4-iber Adapter odule 4-iber Adapter odule 4-iber Adapter odule 4-iber Adapter odule 100 GbE Cross-Connect iber PO Patch Cord A-Polarity (Type A) 4-iber PO Patch Cord 4-iber PO Patch Cord A-Polarity (Type A) PO Adapter odule 4-iber Trunk RG 4RU Chassis RG 1 RU Chassis RG RU Chassis RG 4 RU Chassis Page ax: AE 1/13

25 RG 4-iber 100 Gigabit Cross-Connect ORDERING INORATION 100 Gigabit PO to PO Cross-Connect s Number Component Part Number 1 4-ber PO Patch Cord, Polarity A (Type A) PT-1CC40xxx-NN PO Adapter odule RG-7ADPP 3 4-iber Trunk, Polarity A (Type A) PT-CC40xxx-NN 4 4-iber PO Patch Cord, Polarity B (Type B) P-1C1C40xxx-NN N/S Chassis 1 RU RG B N/S Chassis RU RG B N/S Chassis 4 RU RG B Note: x or xxx denotes length for feet or for meters Specifications POptimate Performance: Standard iber Path: 4-iber Trunk: Patch cords used in Pairs: Compatible with POptimate trunks and arrays Compatible with TIA 568-C.0- draft standard for polarity method "A" trunks Up to six 4-fiber PO trunks per module Assures proper fiber map, polarity and location of PO alignment pins 100 GbE Cross-Connect Page ax: AE 1/13

26

27

28 Contact us: Greensboro, NC USA Tel: ax: Tyco Electronics and ADC are now TE Connectivity POptimate, Quareo, TE Connectivity, TE connectivity (logo), Tyco Electronics, and TE (logo) are trademarks of the TE Connectivity Ltd. family of companies and its licensors. While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, TE Connectivity does not guarantee that it is error-free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE Connectivity reserves the right to make any adjustments to the information contained herein at any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE Connectivity for the latest dimensions and design specifications. Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved AE 1/13

24-Fiber MPO System. 10/40/100 GbE Migration Solution High Density Equipment Panel (HDEP) Ordering Guide

24-Fiber MPO System. 10/40/100 GbE Migration Solution High Density Equipment Panel (HDEP) Ordering Guide 4-Fiber System 10/40/100 GbE Migration Solution High Density Equipment Panel (HDEP) Ordering Guide Table of Contents HDEP System Overview... 3 HDEP 4-Fiber Interconnect System 10 Gigabit Interconnect Introduction...4

More information

24-Fiber MPO System 10/40/100 GbE Migration Solution HIGH DENSITY EQUIPMENT PANEL (HDEP) ORDERING GUIDE

24-Fiber MPO System 10/40/100 GbE Migration Solution HIGH DENSITY EQUIPMENT PANEL (HDEP) ORDERING GUIDE 4-Fiber System 10/40/100 GbE Migration Solution HIGH DENSITY EQUIPMENT PANEL (HDEP) ORDERING GUIDE Table of Contents HDEP System Overview 3 HDEP 4-Fiber Interconnect System 10 Gigabit Interconnect Introduction...

More information

RMG Series Rack Mount Fiber Enclosures

RMG Series Rack Mount Fiber Enclosures The RMG Series rack mount fiber enclosures is as an integral part of the TE Connectivity product portfolio. The RMG Series fiber enclosure provides rugged and durable protection for patching or splicing

More information

TrueNet TFP Series Rack Mount Fiber Panels

TrueNet TFP Series Rack Mount Fiber Panels TFP Series Rack Mount Fiber Panels The rack mount TrueNet Fiber Panel (TFP) is an integral part of the TrueNet Fiber product portfolio. The TFP fiber panels can be ordered in one, two and five rack unit

More information

Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS

Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Xtreme12 is Opticonx s Base-12 cabling solution for easy migration of 10/25/40/50/100 and 400G parallel optics deployments in the data center. This

More information

Q4000 SERIES. Featuring Quareo Technology

Q4000 SERIES. Featuring Quareo Technology Place hero product image here shorter square image space available. Q4000 SERIES Q4000 Series featuring Quareo Technology allows network personnel to view, manage and audit the physical layer. This means,

More information

TrueNet WMG Series Wall Mount Fiber Enclosures

TrueNet WMG Series Wall Mount Fiber Enclosures The TrueNet WMG Series wall mount fiber enclosures are ideal for LAN applications requiring a fully enclosed and lockable wall mount enclosure. The cabinets are one or two door direct termination and splice

More information

Fiber Backbone Cabling in Buildings

Fiber Backbone Cabling in Buildings White Paper Fiber Backbone Cabling in Buildings www.commscope.com Contents Introduction 3 Backbone Cabling Speeds 3 Optical Fiber in the Backbone 4 b/s Optical Fiber Backbone 4 Migrating to 40 Gbps and

More information

Don t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of 32G to 400G

Don t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of 32G to 400G Don t Get Left Behind: Cabling Designs You Can Trust to Support Speeds of G to 00G Dave Fredricks Data Center Infrastructure Architect #DATACENTERWORLD #CPEXPO CHANNELPARTNERSCONFERENCE.COM DATACENTERWORLD.COM

More information

Solutions. Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS

Solutions. Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Solutions Solutions FOR DATA CENTERS AND STORAGE AREA NETWORKS Xtreme8 is Opticonx s Base-8 cabling solution for easy migration of 10/40/100 and 400G parallel optics deployments in the data center. This

More information

C2LINX. Ordering Guide

C2LINX. Ordering Guide Ordering Guide Table of Contents Overview... 3 Key Benefits... 3 Panels... 3 Section One: Chassis... 4 Section 3: Trays... 5 Section 4: Modules... 6 a. Patch... 6 b. Patch and Splice... 7 c. Pre-terminated

More information

Plug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product

Plug & Play Universal Low-Loss Systems A LANscape Pretium Solutions Product Applications Data Center LAN/SAN Enterprise Building Backbone -to-the-desk Description Plug & Play Universal Systems are preterminated optical fiber cabling systems designed to dramatically improve performance

More information

Port Mapping the Cisco Nexus 9K Switch

Port Mapping the Cisco Nexus 9K Switch February 2018 Port Mapping the Cisco Nexus 9K Switch Mapping 36 Port Spine Blades to a Centralized Patching Location with the HD Flex Fiber Cabling System Introduction Customers seek to leverage the Cisco*

More information

White Paper: Testing Strategies for SYSTIMAX High Speed Migration Solutions

White Paper: Testing Strategies for SYSTIMAX High Speed Migration Solutions White Paper: Testing Strategies for SYSTIMAX High Speed Migration Solutions Exploding demand for bandwidth is pushing data center teams to rethink their network infrastructure as they look to support faster

More information

Corning Distance and Link-Loss Budgets for the Cisco 40GbE BiDi Transceiver

Corning Distance and Link-Loss Budgets for the Cisco 40GbE BiDi Transceiver 9 0 Corning Distance and Link-Loss Budgets for the Cisco 0GbE BiDi Transceiver This paper discusses the following topics for the Cisco bidirectional (BiDi) transceiver: Cisco quad small-form-factor pluggable

More information

FAS-NET MPO Solution. Benefits of FAS-NET MPO Fiber Optic Solution:

FAS-NET MPO Solution. Benefits of FAS-NET MPO Fiber Optic Solution: Stable and Reliable Data Communication Solutions from Infinique Infinique has designed and developed quality product with affordable pricing for communication infrastructure solutions. This position has

More information

Base 8 Plug & Play. Fiber Solutions

Base 8 Plug & Play. Fiber Solutions Base 8 Plug & Play Fiber Solutions WWW.SIEMON.COM 8 About Base 8 Plug & Play Current 40 Gig (40GBASE-SR4) and 100 Gig (100GBASE-SR4) multimode fiber applications, as well as future 200 and 400 Gig multimode

More information

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations White Paper www.commscope.com Contents Introduction 3 CommScope solution overview 3 InstaPATCH

More information

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Pretium EDGE HD solutions create a fiber optic tip-to-tip solution for data centers and storage area networks (SANs)

More information

Connectivity Solutions Utilizing Base-8 Structured Cabling

Connectivity Solutions Utilizing Base-8 Structured Cabling Engineering Services Department 800 7th St NW PO Box 489 Hickory, North Carolina 860-0489 800 74-67 f 88 90-55 www.corning.com/cablesystems Connectivity Solutions Utilizing Base-8 Structured Cabling AEN

More information

z-quad SMALL FORM-FACTOR PLUGGABLE PLUS (zqsfp+ OR QSFP28/56) INTERCONNECT SYSTEM

z-quad SMALL FORM-FACTOR PLUGGABLE PLUS (zqsfp+ OR QSFP28/56) INTERCONNECT SYSTEM z-quad SMALL FORM-FACTOR PLUGGABLE PLUS (zqsfp+ OR QSFP28/56) INTERCONNECT SYSTEM Quick Reference Guide te.com/products/qsfp Introducing zqsfp+ Interconnect System TE Connectivity s (TE) zqsfp+ interconnects

More information

Sensus. Sensus High-Density Panels for Aggregation and Breakout

Sensus. Sensus High-Density Panels for Aggregation and Breakout Sensus High-Density Panels for Aggregation and Breakout Mountain s Sensus intelligent panels aggregate and break out fiber connectivity from duplex LC cables to high density 8-fiber, 12- fiber and 24-fiber

More information

Internal tray pulls out towards the user, providing room to manage the fiber cable behind the fiber adapter panels or cassettes.

Internal tray pulls out towards the user, providing room to manage the fiber cable behind the fiber adapter panels or cassettes. JPM427A-R2 1U Pull-Out Fiber Splice Tray Enclosure Internal tray pulls out towards the user, providing room to manage the fiber cable behind the fiber adapter panels or cassettes. Supports up to three

More information

FPX Series Fiber Panels Next Generation FPL

FPX Series Fiber Panels Next Generation FPL TE Connectivity's (TE) FPX series provides industry-leading fiber cable protection and management in a modular footprint. The panel utilizes an internal splicing system that creates a compact, feature-rich,

More information

Opt-X Unity. 40/100G Fiber Optic System

Opt-X Unity. 40/100G Fiber Optic System Opt-X Unity 40/100G Fiber Optic System PREPARE FOR 40/100G WITH THE LEVITON PRE-TERMINATED FIBER MULTIMODE SYSTEM The Opt-X Unity 40/100G laser optimized multimode (LOMM) system offers an ideal migration

More information

High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center

High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center Table of Contents Introduction 3 Figure 1 - The Ethernet road map 3 Planning considerations 4 Fiber

More information

HIGH SPEED INPUT/OUTPUT SOLUTIONS QUICK REFERENCE GUIDE

HIGH SPEED INPUT/OUTPUT SOLUTIONS QUICK REFERENCE GUIDE HIGH SPEED INPUT/OUTPUT SOLUTIONS QUICK REFERENCE GUIDE The pluggable I/O interface offers significant advantages as a high speed I/O interconnect. With a standard equipment I/O interface and the flexibility

More information

PRE-TERMINATED SOLUTION GUIDE

PRE-TERMINATED SOLUTION GUIDE PRE-TERMINATED SOLUTION GUIDE About A global leader in fiber optic technology, AFL Hyperscale brings together over 70 years of design and manufacturing expertise to create next generation, end to end

More information

Simplify Fiber Optic Cabling Migrations with a Multi-Path System

Simplify Fiber Optic Cabling Migrations with a Multi-Path System Simplify Fiber Optic Cabling Migrations with a Multi-Path System By Dave Fredricks, Data Center Infrastructure Architect, CABLExpress and Rick Dallmann, Sr. Data Center Infrastructure Architect, CABLExpress

More information

InstaPATCH Cu Cabling Solutions for Data Centers

InstaPATCH Cu Cabling Solutions for Data Centers SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 InstaPATCH Cu Solution Specification 2 Harness Assembly Design 3

More information

Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity

Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity Introduction Virtualization and cloud technologies have applied an incredible amount of pressure

More information

HI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology.

HI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology. APPLICATION HI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology. This product set is designed for installation in the data

More information

The Drivers Behind High-Density Systems

The Drivers Behind High-Density Systems 2 The average cost of unplanned data center outages is nearly $9,000 per minute. 1 Maximum downtime costs are rising faster than average, increasing 81% since 2010 to a current high of $2,409,991. 1 Cybercrime

More information

Fiber backbone cabling in buildings

Fiber backbone cabling in buildings White paper Fiber backbone cabling in buildings www.commscope.com 1 Contents Introduction 3 Backbone cabling speeds 3 Optical fiber in the backbone 3 10 Gbps optical fiber backbone 3 Migrating to 40 Gbps

More information

MTP/MPO Cable Assemblies

MTP/MPO Cable Assemblies MTP/MPO Cable Assemblies MTP cable assemblies are multi-fiber patch cords suitable for high-density back plane and PCB solutions. MTP brand Fan-Out, Interconnect and Trunk cable offer up to 36 times the

More information

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions Fiber Optics LAN Section Part of the Telecommunications Industry

More information

Siemon PON Fiber Cabling Solutions

Siemon PON Fiber Cabling Solutions Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility

More information

Design of the Physical Layer

Design of the Physical Layer Design of the Physical Layer Critical Choices for Today's Data Centres The Siemon Company: The partner of choice for your Global Data Centers Alberto Zucchinali RCDD Senior Technical Manager EMEA DC Solutions

More information

SYSTIMAX EHD ULL fiber panels solution guide. Enhanced high-density fiber solutions for ultra low-loss applications

SYSTIMAX EHD ULL fiber panels solution guide. Enhanced high-density fiber solutions for ultra low-loss applications SYSTIMX EHD LL fiber panels solution guide Enhanced high-density fiber solutions for ultra low- applications By 0, global data center IP traffic will hit 5. zettabytes (ZB) a year. On the surface, handling

More information

Sensus High-Density Panels for Aggregation and Breakout

Sensus High-Density Panels for Aggregation and Breakout Specifications Chassis Specifications Weight Rack Mounting Slots Dimensions (H/W/D) 4.15 lbs Fits 19, 21 and 23 racks 3 (2 patching modules, 1 management module) 3.45 x 17.44 x 8.67 (8.67 cm x 44.30 cm

More information

QuickNet Harness Cable Assemblies Solution Guide for Switching Applications

QuickNet Harness Cable Assemblies Solution Guide for Switching Applications QuickNet Harness Cable Assemblies Solution Guide f Switching Applications March 2014 AN-01 QuickNet Harness Cable Assemblies Solution Guide f Switching Applications An end-to-end pre-terminated cabling

More information

OM3/OM4 FIBER CABLING SYSTEM. System Benefits

OM3/OM4 FIBER CABLING SYSTEM. System Benefits About ncompass ncompass is an innovative product offering of structured cabling solutions created by Legrand and Superior Essex. Understanding your communications challenges allows us to offer you multiple,

More information

High-Density Connectivity Solutions. Network Cabling Products

High-Density Connectivity Solutions. Network Cabling Products High-Density Connectivity Solutions Network Cabling Products High-Density Solutions for Enhancing Network Performance HellermannTyton has combined the technologies of high-density connectivity with the

More information

Distributed Antenna Systems For Wireless Coverage and Capacity

Distributed Antenna Systems For Wireless Coverage and Capacity Distributed Antenna Systems For Wireless Coverage and Capacity TE DAS Solutions HIGH POWER AND LOW POWER DAS TE is the market leader for distributed wireless coverage and capacity. Our solutions operate

More information

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters HIGH DENSITY DATA CENTER CABLING GUIDE Optics DACs Cables Cable Management Fiber TAPs Media Converters PROVIDING MTP CABLING SOLUTIONS FOR THE SMART DATA CENTER. APPROVED NETWORKS SETS THE STANDARD The

More information

ARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1. ARISTA 7500R/7500E/7300X Connectivity Guide

ARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1. ARISTA 7500R/7500E/7300X Connectivity Guide ARISTA 7500R/7500E/7300X Connectivity Guide CABLExpress 1 ARISTA 7500R/7500E/7300X Connectivity Guide How do you protect and improve the functionality of your critical processes? You have to Respect Layer

More information

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress is a manufacturer of

More information

Pretium EDGE FX Solutions

Pretium EDGE FX Solutions Pretium EDGE FX Solutions for Enterprise Data Centers and Storage Area Networks Corning Cable Systems Pretium EDGE FX Solutions create a fixed-tray fiber optic tip-to-tip solution for Data Centers and

More information

Plug & Play Universal Systems

Plug & Play Universal Systems 100G Ready performance Maximum skew of 0.75 ns Product is assured to work in parallel optic applications for Ethernet, Fibre Channel and InfiniBand MTP /LC Duplex Module TRAINING SPLICE EQUIPMENT High-density

More information

2 visit

2 visit 2 visit www.panduit.com/hdflex :: At Amazon, every 100 milliseconds of latency costs them 1% in sales. 1, 2 :: At Google, an extra 0.5 seconds in search page generation time dropped traffic by 20%. 1,

More information

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2) Plug & Play Universal Systems Harnesses have a pinned (male) MTP connector on one end that connects to a Plug & Play Universal Systems trunk or extender trunk, while the other end is equipped with single

More information

Advances in Fiber Tier 2 Enterprise & Data Center Testing

Advances in Fiber Tier 2 Enterprise & Data Center Testing Advances in Fiber Tier 2 Enterprise & Data Center Testing As the volume of fibers deployed into enterprise increases significantly, fiber cabling advances like multi-fiber (MPO) connectors and interfaces

More information

Trends in Data Centre

Trends in Data Centre Trends in Data Centre The impact on the IT infrastructure Thomas Ko Product Manager Market Situation Standards Update and Topology 40G and 100G Ethernet - Impact on IT Cabling Migration Options with Fiber

More information

CommScope and Cisco - The ideal connectivity system for multilayer directors

CommScope and Cisco - The ideal connectivity system for multilayer directors CommScope and Cisco - The ideal connectivity system for multilayer directors - SYSTIMAX InstaPATCH 360 Ultra High Density Solution - SYSTIMAX InstaPATCH Cu - Cisco MDS 9500 and Nexus 7000 Series The Ideal

More information

Pre-Terminated. FiberExpress

Pre-Terminated. FiberExpress FiberExpress Pre-Terminated Product Bulletin PB141E LSNH ssemblies The new line of Belden low-smoke, no-halogen (LSNH) pre-terminated fiber assemblies offers faster data center deployment, better performance

More information

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Product names mentioned in this manual may be trademarks or registered trademarks of those products. FCC Statement The FCC (Federal Communications Commission) restricts the amount of radio frequency emission and radiation coming from computer equipment. The equipment introduced in this manual has been

More information

Data Center & Cloud Computing Infrastructure Solutions DATASHEET. MTP/MPO-LC/SC Cassette High-density Pre-terminated Modular Cassette System

Data Center & Cloud Computing Infrastructure Solutions DATASHEET. MTP/MPO-LC/SC Cassette High-density Pre-terminated Modular Cassette System Data Center & Cloud Computing Infrastructure Solutions DATASHEET MTP/MPO-LC/SC Cassette High-density Pre-terminated Modular Cassette System REV.1.0 2018 MTP MPO Cassette 01 Description FS.COM Fiber Optic

More information

Accelerating Light STAR. Data Center High Density Connectivity Solution

Accelerating Light STAR. Data Center High Density Connectivity Solution Accelerating Light STAR Data Center High Density Connectivity Solution STAR High Density Connectivity Solution STAR is a cost-effective modular solution that harnesses ultra-high density pre-terminated

More information

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules PowerEdge FX - Upgrading from 0GbE Pass-through Modules to FN40S I/O Modules Dell Networking Solutions Engineering June 06 A Dell EMC Deployment and Configuration Guide Revisions Date Revision Description

More information

take your data centre to the next level

take your data centre to the next level The data centre is the hub of your optical network transmitting, storing and protecting the information upon which your business relies. So what makes your network any different than your competitor s

More information

Ultra High Density Fiber Enclosure

Ultra High Density Fiber Enclosure LightStack Ultra High Density Fiber Enclosure As today s high density Data Centers migrate from 10 to 40 and 100 gigabit speeds, they require low loss fiber connectivity to support multiple mated connections

More information

IBM Europe Announcement ZG , dated February 13, 2007

IBM Europe Announcement ZG , dated February 13, 2007 IBM Europe Announcement ZG07-0221, dated February 13, 2007 Cisco MDS 9200 for IBM System Storage switches, models 9216i and 9216A, offer enhanced performance, scalability, multiprotocol capabilities, and

More information

FTTE Revisited for New Technologies

FTTE Revisited for New Technologies FTTE Revisited for New Technologies A new look into FTTE design to allow great flexibility as well as compliance to the latest 40G and 100G. Gautier Humbert, RCDD, CDCDP Business Development Manager Eastern

More information

Cabling Best Practices Using Fast Channel TM Switch Connect. Marc Dunham, Methode - Data Solutions

Cabling Best Practices Using Fast Channel TM Switch Connect. Marc Dunham, Methode - Data Solutions Cabling Best Practices Using Fast Channel TM Switch Connect Marc Dunham, Methode - Data Solutions ABSTRACT With the continued growth of port count density in data center hardware, end users are presented

More information

Optical Fiber Networks: Industry. and New Options for Networks

Optical Fiber Networks: Industry. and New Options for Networks Optical Fiber Networks: Industry Trends, Application Influences and New Options for Networks Herbert V Congdon II, PE Manager, Standards & Technology Tyco Electronics AMP NETCONNECT Solutions Preview Deciding

More information

Conflicts in Data Center Fiber Structured Cabling Standards

Conflicts in Data Center Fiber Structured Cabling Standards Conflicts in Data Center Fiber Structured Cabling Standards By Dave Fredricks, CABLExpress Data Center Infrastructure Architect Various telecommunications and data center (DC)-specific standards are commonly

More information

CommScope standard density fiber optic panels

CommScope standard density fiber optic panels CommScope standard density fiber optic panels High-performance communication solutions www.capital-electric.com CAPITAL ELECTRIC WIRE & CABLE COMPANY 16680 W. Cleveland Ave New Berlin WI 53151 (800) 227-9473

More information

ISILON ETHERNET BACKEND NETWORK OVERVIEW

ISILON ETHERNET BACKEND NETWORK OVERVIEW WHITE PAPER ISILON ETHERNET BACKEND NETWORK OVERVIEW Abstract This white paper provides an introduction to the Ethernet backend network for Dell EMC Isilon scale-out NAS. November 2018 Isilon 1 Isilon

More information

Volition. Fast Ethernet Fiber Optic Media Converters. Installation Manual VOL-0205/VOL-0206 /VOL-0207/VOL December

Volition. Fast Ethernet Fiber Optic Media Converters. Installation Manual VOL-0205/VOL-0206 /VOL-0207/VOL December Volition Fast Ethernet Fiber Optic Media Converters VOL-0205/VOL-0206 /VOL-0207/VOL-0208 Installation Manual TM December 1998 78-8110-6491-0 1 1.0 Introduction 1.01 The VOL-0206/VOL-0208 Media Converter

More information

BUILDING NETWORK SOLUTIONS GUIDE

BUILDING NETWORK SOLUTIONS GUIDE BUILDING NETWORK SOLUTIONS GUIDE designed to be better. INTEGRATED SOLUTIONS BUILDING NETWORK CHALLENGES Constantly evolving technologies are driving connectivity expectations and moving interactions to

More information

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND Cindy Montstream, RCDD/NTS, EE, CPLP Director of elearning and Standards DATA COMMUNICATIONS

More information

3M Passive Optical Splitter Shelves and Modules

3M Passive Optical Splitter Shelves and Modules Communication Markets Division 3M Passive Optical Splitter Shelves and Modules 3M offers a robust portfolio of passive optical fiber splitter products made to enable easy configuration, design, ordering,

More information

Opt-X Unity. Fiber Optic Migration System

Opt-X Unity. Fiber Optic Migration System Opt-X Unity Fiber Optic Migration System PRE-TERMINATED FIBER MIGRATION SYSTEM The Opt-X Unity 40, 100, 200, 400 Gb/s system offers an ideal migration path to speeds beyond 10GbE, and meets the IEEE and

More information

Opt-X Unity. Fiber Optic Migration System

Opt-X Unity. Fiber Optic Migration System Opt-X Unity Fiber Optic Migration System PRE-TERMINATED FIBER MIGRATION SYSTEM The Opt-X Unity 40, 100, 200, 400 Gb/s system offers an ideal migration path to speeds beyond 10 GbE, and meets IEEE and MSA

More information

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45. Volition VF-45 Singlemode Socket and Patch Cords IT'S AS EASY AS PLUGGING IN AN RJ-45. The Volition VF-45 Singlemode Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnect products

More information

FMT4S. High Density Connectivity Solution

FMT4S. High Density Connectivity Solution FMT4S High Density Connectivity Solution 2 FMT4S Solution Illustration FMT4S Optical Distribution Frame (ODF) FMT4S series is an advanced ODF series offering premium quality Data Center connectivity solution.

More information

ORTRONICS SNAP CLARITY TERMINATED COPPER CABLING SYSTEMS & PORT REPLICATION. designed to be better.

ORTRONICS SNAP CLARITY TERMINATED COPPER CABLING SYSTEMS & PORT REPLICATION. designed to be better. ORTRONICS CLARITY SNAP TERMINATED COPPER CABLING SYSTEMS & PORT REPLICATION designed to be better. QUICK AND RELIABLE DATA CENTER INSTALLATIONS ARE A SNAP WITH THE LATEST INNOVATION FROM LEGRAND. 2 In

More information

micro QUAD SMALL FORM-FACTOR PLUGGABLE FOUR CHANNEL PLUGGABLE TRANSCEIVER, HOST CONNECTOR, & CAGE ASSEMBLY FORM FACTOR

micro QUAD SMALL FORM-FACTOR PLUGGABLE FOUR CHANNEL PLUGGABLE TRANSCEIVER, HOST CONNECTOR, & CAGE ASSEMBLY FORM FACTOR 1 2 3 4 5 6 7 8 9 10 11 microqsfp Draft Mechanical Specification Rev 1.0 Draft Mechanical Specification for micro QUAD SMALL FORM-FACTOR PLUGGABLE FOUR CHANNEL PLUGGABLE TRANSCEIVER, HOST CONNECTOR, &

More information

Choosing the Correct Harness for your Switch

Choosing the Correct Harness for your Switch Choosing the Correct for your Switch AEN 157, Revision: 3 This Application Engineering Note will serve as a guide to selecting the best Corning Optical Communications MTP to LC harness for your structured

More information

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation Volition Multimode VF-45 Socket and Patch Cords O b D s oc ol e um te en t It's as easy as plugging in a rj-45. The Volition VF-45 Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnects

More information

HD Flex Zero RU Cassette Holder and Bracket

HD Flex Zero RU Cassette Holder and Bracket HD Flex Zero RU Cassette Holder and Bracket Part Numbers: FLEX-0RUBR**, FLEX0RUCH** Panduit Corp. 2016 INSTALLATION INSTRUCTIONS The Zero RU Cassette Holder and Bracket are designed to mount on the side

More information

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect How to Decide on Optical Fibre Termination Options Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect Termination Choices Optical Fiber Cabling in Data Center Options available Traditional

More information

Applications Engineering Notes. The US Conec MTP Multifiber Connector

Applications Engineering Notes. The US Conec MTP Multifiber Connector Applications Engineering Notes Document Title Document Number The US Conec MTP Multifiber Connector AEN-1909 Revision Number Rev 2.0 Effective Date June 1, 2008 1.0 Document Purpose The purpose of this

More information

Are Conflicts in Data Center Fiber Optic Structured Cabling Standards Putting Your Organization at Risk?

Are Conflicts in Data Center Fiber Optic Structured Cabling Standards Putting Your Organization at Risk? Are Conflicts in Data Center Fiber Optic Structured Cabling Standards Putting Your Organization at Risk? Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress

More information

SYSTIMAX Rack and Cabinet Solution

SYSTIMAX Rack and Cabinet Solution SYSTIMAX Rack and Cabinet Solution The SYSTIMAX Rack and Cabinet Solution offer is designed for use in telecommunications equipment installations, providing our SYSTIMAX BusinessPartners and customers

More information

HUBER+SUHNER DCCT Training

HUBER+SUHNER DCCT Training HUBER+SUHNER DCCT Training DCCT training The following topics are covered throughout the 2 course: Fiber optic fundamentals This is an optional section of the training which covers the basics about fiber

More information

QuickNet Harness Cable Assemblies Solution Guide for Switching Applications FBAN-07 March 2014

QuickNet Harness Cable Assemblies Solution Guide for Switching Applications FBAN-07 March 2014 QuickNet Harness Cable Assemblies Solution Guide f Switching Applications FBAN-0 March 0 AN-0 0 0 0 0 0 NK-MXP- 0 0 NK-MXP- 0 0 NK-MXP- 0 0 PSU FAN SUP FAB M SERIAL PORT IVE CONSOLE COM/AUX NK-SUP USB

More information

DATA CENTER SOLUTIONS

DATA CENTER SOLUTIONS DATA CENTER SOLUTIONS MTP Cabling Solutions MTP Cassette Solutions MTP Distribution Center Solutions Aqua 10 (OM3) Gigabit Patchcords Tera Flow Single Mode Bend Insensitive Patchcords Fiber Optic Taps

More information

IBM TotalStorage SAN Switch M12

IBM TotalStorage SAN Switch M12 High availability director supports highly scalable fabrics for large enterprise SANs IBM TotalStorage SAN Switch M12 High port density packaging saves space Highlights Enterprise-level scalability and

More information

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions

Tim Takala RCDD. Vice President Field Application Engineer APAC. Mobility is Driving Changing Network Architectures & Transceiver Evolutions Tim Takala RCDD Vice President Field Application Engineer APAC Mobility is Driving Changing Network Architectures & Transceiver Evolutions 5TOP TRENDS SHAPING NETWORKS 1. Mobility 2. Connected Devices

More information

zsfp+ (SFP28) 28 GBPS PLUGGABLE I/O INTERCONNECT

zsfp+ (SFP28) 28 GBPS PLUGGABLE I/O INTERCONNECT zsfp+ (SFP28) 28 GBPS PLUGGABLE I/O INTERCONNECT The zsfp+ interconnect is currently one of the fastest single-channel I/O connectors on the market today, transferring data at 28 Gbps with possible expansion

More information

Patch by Exception Module Jackfield User Manual

Patch by Exception Module Jackfield User Manual ADCP-0-00 Issue, October 99 Patch by Exception Module Jackfield User Manual Content Page TRODUCTION... Revision History.... GENERAL.... DESCRIPTION... A. Functional Description... B. Physical Description....

More information

Xmultiple Technology SFP Products Information

Xmultiple Technology SFP Products Information Xmultiple Technology SFP Products Information SFP Products Fiber Channel InfiniBand Ethernet SFP Product Types Optic Modules SFP System Copper HSSDC2 Module HSSDC2 Cable Assemblies PT Connectors SFP History

More information

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System Application Specification 114-32037 29 AUG 12 NOTE i All numerical values are in metric units [with U.S. customary units in brackets].

More information

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation Volition Multimode VF-45 Socket and Patch Cords It's as easy as plugging in a rj-45. The Volition VF-45 Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnects for affordable, high

More information

Snap Server 4400 Power Supply

Snap Server 4400 Power Supply Snap Server 4400 Power Supply Snap Server 4400 Note You can set up your system to send an e-mail alert in the event of a hardware failure. For details, see the section on e-mail notification in your Administrator

More information

Deploying 10 Gigabit Ethernet with Cisco Nexus 5000 Series Switches

Deploying 10 Gigabit Ethernet with Cisco Nexus 5000 Series Switches Deploying 10 Gigabit Ethernet with Cisco Nexus 5000 Series Switches Introduction Today s data centers are being transformed as the most recent server technologies are deployed in them. Multisocket servers

More information

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway Cisco DCM Series D9901 Digital Content Manager IP Video Gateway Today s video contribution networks are evolving rapidly with the dual drivers of increased demand, for high-definition TV, and a need for

More information

PHOENIX OPTIX LUMINIX CABLING SYSTEM

PHOENIX OPTIX LUMINIX CABLING SYSTEM PHOENIX OPTIX LUMINIX CABLING SYSTEM High-Performance Fiber-Optic Cabling Using Multifiber MTP for Faster Installation, Higher Rack Densities, and an Easier Transition to 40/100G AEROSPACE, DEFENSE & MARINE

More information

An Oracle White Paper December Accelerating Deployment of Virtualized Infrastructures with the Oracle VM Blade Cluster Reference Configuration

An Oracle White Paper December Accelerating Deployment of Virtualized Infrastructures with the Oracle VM Blade Cluster Reference Configuration An Oracle White Paper December 2010 Accelerating Deployment of Virtualized Infrastructures with the Oracle VM Blade Cluster Reference Configuration Introduction...1 Overview of the Oracle VM Blade Cluster

More information