1 Engineering White Paper Introduction to the CX700 Abstract This white paper introduces the full 2 Gb architecture and functionality of the CX700 storage system. It compares the features and capabilities of the CX700 with other EMC CLARiiON storage systems. The document lists the software capabilities and also introduces the new features of the CX700. Published 3/22/2004

2 Copyright 2004 EMC Corporation. All rights reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. Part Number C1047 Introduction to the CX700 2

3 Table of Contents Executive Summary...4 Intended Audience...4 Introduction...4 Where the CX700 Fits into the EMC CLARiiON Storage Family... 5 The CX700 Major Subassemblies...6 The CX700 Storage Processor... 6 The CX700 Drive Enclosures SPE and DAE The CX700 Drive Canister... 9 The Standby Power Supply Cabling the CX700 Storage System Software on the CX FLARE Operating Environment Navisphere Management Suites MetaLUNs Access Logix (Included with Navisphere Management Suites) SnapView Snapshots (Optional Application) SnapView BCVs (Optional Application) MirrorView (Optional Application) SAN Copy (Optional Application) PowerPath Non-Disruptive Upgrade Upgrading from a CX300/CX Summary...15 Appendix A...16 Introduction to the CX700 3

4 Executive Summary This document describes the full 2 Gb architecture and functionality of the CX700 storage system. It compares the features and capabilities of CX700 with other CLARiiON storage systems. The CX700 storage processors (SPs) and SP subcomponents are described. In addition, major system subassemblies and configurations are described and illustrated. The paper provides details on the software capabilities of the CX700 and also introduces the new features of the CX700. Intended Audience This white paper is intended for Systems Engineers, EMC partners, members of the EMC and partners sales and professional services communities, and any technical individuals who desire an in-depth understanding of the CLARiiON CX700 storage system. Introduction The CX700 is the flagship of the EMC seventh-generation, full Fibre Channel CLARiiON CX series storage systems. The CX700 is made up of the following modular components: The 2 Gb storage processor enclosure (SPE) - houses only the storage processors (SPs) A 2 Gb disk array enclosure (DAE2) - houses up to 15 drives and can be added to, to scale to a maximum of 240 drives A standby power supply (SPS) for protection of the system s mirrored write cache The following are CX700 data storage system features: Supports both direct-attach and shared storage (SAN) environments Hot-swappable storage processors with 4 GB bytes of memory per SP FC-AL and FC-SW front-end support RAID level 0, 1, 1/0, 3, 5 and individual disk support, along with global hot sparing Nondisruptive upgrade (NDU) capability Five-drive minimum to 240-drive maximum system configuration Supports data-in-place upgrade from the CX300 or the CX500, as well as prior generation CX models Supports Windows, Solaris, Netware, Linux, HP-UX, TRU64, and AIX operating systems The CX700 supports the following software: Base (FLARE ) Code Navisphere Management Suites (include Access Logix technology and appropriate Navisphere Agents) CLARalert PowerPath (Full-Featured or Utility Kit) SnapView (Snapshots and BCVs) MirrorView SAN Copy Introduction to the CX700 4

5 Where the CX700 Fits into the EMC CLARiiON Storage Family The CX700 storage system is an intelligent storage product in the CLARiiON CX product family. It provides high functionality, disaster tolerance, data integrity, high availability, and configurability. It is an excellent choice for a high-end midrange storage solution. The new CX700 hardware provides significantly higher performance than its predecessor, the CX600 system. All CX700 storage systems are shipped with 4 GB of cache and dual 3.0 GHz processors on each SP. This contrasts with the CX600, which was available with 2 GB or 4 GB of cache and 2.0 GHz processors on each SP. There are now four back-end ports on each SP, twice what the CX600 had. A fully loaded CX700 with GB drives provides approximately 35 TB of raw storage, which is the same as its predecessor. The maximum capacity increases even more dramatically when ATA drives are implemented. See Table 1 for a comparison of many of the CX700 features with those of the CLARiiON CX600 storage system. Table 1. Side-by-Side Comparison of the CX700 with the CLARiiON CX600 Storage System Components/Connectivity CX600 CX700 Processor architecture per SP 2 x 2 GHz 2 x 3 GHz Physical memory per SP 4 or 2 GB 4 GB Max drives per storage system Min drives per storage system 4 (5 w/write cache) 4 (5 w/write cache) Max IOPs 150, ,000 Max bandwidth 1300/720 MB/s 1520/1300 MB/s Max front-end FC ports per SP (2 Gb) 4 4 Max back-end FC ports per SP (2 Gb) 2 4 Max initiators per array Max H/A hosts per array Max drives per RAID group Max LUNs per RAID group Max LUNs per array Min configuration form factor 8 U 8 U Software Support SnapView snapshots Yes Yes SnapView BCVs Yes Yes MirrorView Yes Yes SAN Copy Yes Yes Introduction to the CX700 5

6 The CX700 Major Subassemblies The minimal CX700 assembly consists of a 4U SPE, a 1U SPS, and a 3U DAE2, for a total of 8U. A fully configured CX700 consists of the SPE and SPS, plus sixteen 3U DAE2s, for a total of 53U. This would require the use of a second cabinet. Figure 1 shows an 8U assembly and rack mounted system. 3U DAE2 (up to 15 can be added) 3U DAE U maximum configuration 3U DAE2 4U SPE 8U minimum configuration 1U SPS Figure 1. Minimum and Maximum CX700 Configurations The SPS, SPE, and DAE2 assemblies are rack-mounted for efficiency, and allow deployment flexibility. The CLARiiON 40U cabinet with industry-standard 19-inch racks can house different configurations of multiple CX700 systems, as well as 1U FC switches. The 40U cabinet comes standard with two power distribution units (PDUs). Power supplies on the left use the left PDU; power supplies on the right use the right PDU. Additionally, all CLARiiON storage systems can be installed in non-emc industry-standard cabinets. The CX700 Storage Processor Dual 3.06 GHz Intel P4 Xeon processors power each CX700 SP. This processing power is the basis for performance, stability, and reliability in the CX700 storage system. Each SP has 4 GB of system memory, also referred to as cache. There are two 2 Gb Fibre Channel communications messaging interface (CMI) channels between the SPs. All FC protocol chips reside on a 64-bit, 100 MHz PCI-X bus. The LAN and other non-fibre Channel I/O reside on a separate 64-bit, 33 MHz PCI bus. Introduction to the CX700 6

7 Figure 2. CX700 Storage Processor (Back View) Figure 2 shows the CX700 storage processor. LEDs provide indications of LAN connectivity, SP power, boot progress, and fault status, as well as power supply and blower status. Each CX700 SP has four small form factor- (SFF) or Lucent Connector- (LC) style, 2 Gb optical front-end ports. These are unique ports, and can be independently set to run at 1 Gb or 2 Gb speeds. Each SP has four HSSDC-style 2 Gb copper back-end ports which with the peer SP form four redundant FC back-end loops for disk connectivity and capacity expansion. BE 1 BE 0 BE 3 BE 2 4 Back-End Ports (per SP) 4 Front-End Ports (per SP) BE 2 BE 3 BE 0 BE 1 Figure 3. CX700 Storage Processor Front-End and Back-End Ports Introduction to the CX700 7

8 Fan Module Fault Indicators Chassis Power & Fault Indicators Fan Module #3 Fan Module #2 Fan Module #1 Figure 4. CX700 Storage Processor Enclosure (Front View) The SPs are enclosed within the SPE (discussed in the next section). The SPE, first DPE2, and SPS serve as the base unit of the storage system. The CX700 Drive Enclosures SPE and DAE2 The SPE and DAE2 do not use the same enclosure; however, unlike other CX storage systems, the CX700 has a separate enclosure for the SPs, while the first DAE2 contains the drives where the configuration, cache vault, and boot images are stored. The DAE2 enclosure has room for up to 15 drives. Drive 0 is at the furthest left side of the enclosure, and drive 14 is at the furthest right side of the enclosure. Enclosure Fault and Power LEDs Airflow Figure 5. Front View of the CX700 DAE2 Enclosure fault and power status LEDs, as well as disk activity and fault LEDs, are visible from the front of the enclosure. See Figure 5. Other fault indicators and unit ID switches are located at the rear of the enclosure. Introduction to the CX700 8

9 Table 2. Components Housed within SPE and DAE2 Enclosures SPE DAE2 2 CX700 SPs 2 LCCs 2 power supplies 2 power supply/blower assemblies 3 blower assemblies 15 FC or ATA drives disk drives The CLARiiON with ATA implementation is at the DAE2 level. With the exception of the link controller cards (LCCs) and disk modules, all of the other DAE2 assemblies are identical to that of a standard Fibre Channel DAE2 assembly. The LCCs have been modified to convert Fibre Channel signal to serial ATA, and then from serial ATA back to Fibre Channel again. The modified cards are called Bridge Controller Cards (BCCs). For more information on ATA technology, refer to the Introduction to CLARiiON with ATA Disk Drives and Enclosures white paper. The CX700 Drive Canister Figure 6a shows a close-up view of the CX700 FC disk drive canister. The canister holds 1-inch, 12-voltonly disk drives. For additional reliability, the drives are designed with a positive latching mechanism included on the canister itself to ensure a more complete insertion when inserting drives into the CX700 chassis. Each drive canister has drive-ready and fault LEDs. Fibre Channel drives supported at the initial release of the CX700 storage system include the 146 GB 10K rpm, 73 GB 10K/15K rpm, and the 36 GB 10/15K rpm disk drives, all of which are full 2 Gb FC assemblies. Figure 6a. 2 Gb Canister for Fibre Channel d Figure 6b. 2 Gb Canister for ATA drives The CX700 also supports 250GB 5,400 rpm ATA drives. Figure 6b shows the modified ATA disk carrier, allowing for conversion from FC to ATA, and also converting standard single-port access for ATA to dualported access for more highly available and reliable disk access. Introduction to the CX700 9

10 The Standby Power Supply As shown in Figure 7, the CX700 SPE uses the same standby power supply (SPS) as the CX300 and CX500 storage systems. Like the CX500, the CX700 has dual SPSs for redundancy and fault tolerance. One SPS output connector powers up one of the power supplies in the SPE, while the other SPS output powers up the first DAE2, which contains the boot drives. (This is different from the CX300 and the CX500 systems, where only one of the SPS output connectors is used.) Figure 7. View of CX700 Standby Power Supply (SPS) It is important to cable each SPS so it connects completely to either the A-side or the B-side. Looking at the system from the back: SPS on the right: Power-out and sense cables should connect to power supply A and SP A. SPS on the left: Power-out and sense cables should connect to power supply B and SP B. If an SPS is cabled with the SPS sense cable going to SP A and the power-out cable going to power supply B (or vice versa), error conditions will display when the SPSs are tested or are charging. Cabling the CX700 Storage System Figure 8 shows a rear view of the CX700 system in single and multi-rack configurations. Each SP has four back-end loops (BE#0-3). Each disk enclosure that connects to the same back-end loop must have a unique disk enclosure address (for instance, EA#0, EA#1, EA#2, and EA#3). Introduction to the CX700 10

11 Loop 3 LCC B EA1/Loop 3 LCC A Loop 3 EA1/Loop 2 Loop 2 Loop 2 Loop 1 EA1/Loop 1 Loop 1 Loop 0 EA1/Loop 0 Loop 0 EA0/Loop 3 Loop 3 EA0/Loop 2 Loop 3 Loop 2 Loop 1 EA0/Loop 1 EA0/Loop 0 Loop 2 Loop 1 Loop 0 Loop 0 SP A SP B SPS B SPS A Single-Cabinet Cabling (165 Drives Total) EMC2709 LCC B LCC A Loop 0 DAE2 EA7/Loop 2 Loop 0 2 DAE2 EA6/Loop 0 DAE2 EA5/Loop 2 2 LCC B DAE2 EA7/Loop 3 LCC A 0 DAE2 EA4/Loop DAE2 EA6/Loop DAE2 EA3/Loop 2 DAE2 EA2/Loop DAE2 EA5/Loop 3 DAE2 EA4/Loop DAE2 EA1/Loop 2 0 DAE2 EA0/Loop SP B 1-Meter SP A 0 Cable SPS B SPS A DAE2 EA3/Loop 3 DAE2 EA2/Loop 1 DAE2 EA1/Loop 3 DAE2 EA0/Loop or 10-Meter Cable Note: Numbers In circles are loop numbers Multicabinet Cabling (240 Drives Total) EMC2710 Figure 8. CX700 Cabling Diagrams Introduction to the CX700 11

12 Software on the CX700 The CX700 is designed to focus on intelligent storage management functions that can be operated in both direct-attach and SAN environments. The CX700 is capable of incorporating a full range of intelligent storage functions, such as logical unit number (LUN) masking and storage replication applications. FLARE Operating Environment All CX700 drives have an area reserved for configuration information. Additionally, the first five disks in the DAE2 have reserved areas that are used for software images and write cache destage, called the vault area. To provide space to support these features, user space on the first five drives starts at 6.4 GB and starts on all the other drives at 34 MB, as shown in Figure 9. Reserved Space = 6.4 GB Reserved Space = 34 MB User Space User Space First Five Drives All Other Drives Figure 9. CX700 Disk Layout Showing the Private Space Usage (Picture Not to Scale) This layout is also common to the CX500 and CX300 storage systems, as well as to those systems preceding these models. Navisphere Management Suites Customers can manage their CX700 with Navisphere Management Suites. Navisphere allows support for multiple storage systems on the same subnet. Remote management is supported. Navisphere Management Suites also support NAS and/or legacy storage systems, including support for advanced storage applications like SnapView, MirrorView, and SAN Copy. MetaLUNs With Navisphere, the CX700 storage system can utilize the LUN expansion feature, in which the base LUN can be expanded in size to form an entity called the MetaLUN. The MetaLUN is a combination of more than one LUN joined together by using either the striping or concatenation method. Refer to the EMC CLARiiON MetaLUNs, Concepts, Operations, and Management white paper for more detail. If the operating system supports LUN expansion, with the MetaLUN feature a LUN of a larger size will now be visible to the host. Table 3 lists the supported MetaLUN features on the CX700. Introduction to the CX700 12

13 Table 3. MetaLUN features Supported on the CX700 Feature Maximum number of MetaLUNs per storage system 1024 Maximum LUN size (Base or MetaLUN) Maximum number of combinations (striping/concatenation) per Base LUN 16 CX700 Support Access Logix (Included with Navisphere Management Suites) Access Logix includes enabling functions between the storage processors; host bus adapters (HBAs), FC fabric switches, and Navisphere for heterogeneous host connectivity (refer to the EMC Support Matrix for the latest list of supported platforms). Access Logix provides users an easy-to-manage facility of Storage Groups into which they can group their hosts and associated LUNs. The Core (FLARE) software for the CLARiiON storage system that performs all the functions includes both non-access Logix and Access Logix code. Users must install the AccessLogixOption on the storage system to enable the Access Logix capability. Table 4. Access Logix Features Supported on the CX700 Feature Max Storage Groups per storage system 512 Max LUNs per Storage Group (Initiator) TB CX700 Support SnapView Snapshots (Optional Application) SnapView allows users to create an instantaneous virtual copy of a LUN. The virtual copy of the LUN is then accessible from a different host. This enables off-loading of the backup processing from the production host. Third-party backup applications can be scripted using Navisphere CLI and can take full advantage of this functionality. SnapView allows the user to create a virtual copy of the LUN to run decision support applications while not affecting the data on the production database. In case of source corruption, contents of the Snapshot (point-in-time copy) can be rolled back. See Table 5 for the supported SnapView snapshot features on the CX700. Table 5. SnapView Snapshots Supported on the CX700 Feature Snapshots per source LUN 8 Snapshots per storage system 300 Snapshot sessions per source LUN 8 Snapshot sessions per storage system 100 Reserved LUNs for snapshots per storage system 100 CX700 Support SnapView version 2.0 supports persistence. Persistence is maintained by storing the point-in-time view of the source LUN on the Save LUN as updates are made to the source LUN by the host. The point-in-time view remains available after trespasses, NDU operations, and SP reboots. Introduction to the CX700 13

14 SnapView BCVs (Optional Application) SnapView BCVs allow users to create a full copy of a LUN, equal in size to the source LUN. Once created, this full copy can then be fractured from the source LUN and be mounted on a different host for processing backup applications without affecting the production data. A source can have up to eight BCVs and will be contained within a clone group. A clone group consists of all the BCVs that are created for a particular source LUN. In case of source corruption, contents of the BCV can be reverse-synchronized to the source LUN, thus avoiding downtime of the production database. See Table 6 for supported BCV features on the CX700. Table 6. SnapView BCVs Supported on the CX700 Feature BCVs per source LUN 8 BCV images per storage system (includes sources, as well as primary and secondary MirrorView images, in total count) Number of BCVs in a clone group 8 Number of clone groups (source LUNs) per storage system 50 CX700 Support MirrorView (Optional Application) MirrorView allows users to mirror a LUN to an equal-sized LUN resident on a separate storage system. Mirrored LUNs receive host writes simultaneously; MirrorView maintains synchronicity between the LUNs by withholding host acknowledgement of the write until the mirrors have first acknowledged receipt. A source LUN can have up to 2 mirrors (each mirror must be on a separate storage system). Additionally, a given storage system can participate in MirrorView connections with up to 4 other storage systems. Should connectivity be lost between the source LUN and one or all of its mirrors, the areas written to are logged to disk, so that subsequent synchronizations can be incremental (that is, only the data that changed while the mirror was unreachable is transferred once the mirror regains connectivity). Table 7. MirrorView Devices Supported on the CX Feature MirrorView images per storage system (includes primary and secondary images, as well as clone/source images in total count) MirrorView secondaries per primary image CX700 Support (must be on separate storage system) SAN Copy (Optional Application) SAN Copy is a generalized copy facility that enables a CLARiiON storage system to copy data from within a single storage system or from one storage system to another. With SAN Copy, the CX700 can participate in the SAN Copy data transfer operation by serving as either a source or destination of the operation. Since the SAN Copy application is running on the CX700, the software can be used to copy LUNs within the CX700. SAN Copy requires that Access Logix software be installed on the storage system. SAN Copy version 2.0 allows users to maintain incremental tracking of copies, so that only data that has changed on the source is copied to the destination. For incremental copy functionality, the SnapView software package must be running on the storage system. Table 8. SAN Copy Devices Supported on the CX700 Feature SAN Copy sessions per storage system 300 SAN Copy destinations per storage system 100 CX700 Support Introduction to the CX700 14

15 PowerPath EMC PowerPath is host-resident software that works with both CLARiiON and Symmetrix storage systems to deliver intelligent I/O path management. Using PowerPath, administrators can improve the server s ability to manage heavy storage loads through continuous and intelligent I/O balancing. PowerPath automatically configures multiple paths and dynamically tunes for performance as workload changes. PowerPath adds to the high-availability capabilities of the CLARiiON and Symmetrix storage systems by automatically detecting and recovering from server-to-storage path failures. In addition to full-featured PowerPath, the CX700 also supports Utility Kit PowerPath. Utility Kit PowerPath provides failover between SPs only. Customers who desire the ability to load balance and/or have multi-pathing capability will need the full-featured version of PowerPath. Non-Disruptive Upgrade The non-disruptive upgrade (NDU) feature of the CX700 is the implementation of a transparent upgrade mechanism within the CX series storage system product line. The NDU feature, when coupled with PowerPath failover software, allows upgrades of the storage system Core software or other software upgrades, without stopping host access to data. During the NDU process, one SP at a time is upgraded and rebooted during the upgrade. While one SP is upgrading and rebooting, PowerPath failover software redirects I/O through the alternate SP as needed. The NDU function is initiated through either the Navisphere Web-based browser or NaviCLI and upgrades the storage system through several basic steps using the Navisphere management software. The steps are: 1. Select the storage system to be upgraded through the NDU process. 2. Select the software to be used as the upgrade package. 3. Initiate the upgrade process. Upgrading from a CX300/CX500 As the customer s environment grows, a CX300 or CX500 can be upgraded to a CX700. Since hardware and cabling must be reconfigured during the upgrade, the storage system is taken offline. However, there is no data loss or data movement required. This upgrade path is one-way; that is a CX700 or CX500 cannot be downgraded. Older CX storage systems can also be upgraded to current models using a fully supported data-in-place upgrade procedure. Summary The CX700 is a full-featured; full 2 Gb data storage system. It represents the best CLARiiON has to offer with a very attractive price-to-performance ratio. The CX700 shares some common hardware components and storage software functions with the CX300 and CX500 including: management, LUN masking, and path failover. The storage system has 8 front-end FC ports and 8 back-end FC ports, 8 GB of cache memory per storage system, and Ethernet ports for managing the storage system. As with all CLARiiON storage systems, all components are fully redundant. Functional improvements in the CX700 include: New Intel P4 Xeon 3GHz processor 533 MHz front side bus 4 GB memory per SP (no option for 2 GB) DDR PC2100 (266 MHz) 4 Copper HSSDC back-end ports Four separate back-end loops Introduction to the CX700 15

16 Appendix A The following table explains the effect on Write Cache availability for various component failures on the CX700. Component Failure and Write Caching 1st SPS (battery) 2nd SPS (battery) 1st vault drive User induced/ndu Fan * Power supply Storage processor A/C power Write Enabled Write Disabled Write Enabled (Selectable) Write Disabled Write Enabled Write Disabled Write Disabled Write Disabled * Single fan failure note: There are two fans in each of three SPE fan modules, for a total of six fans. Write cache is disabled only after both fans in a single fan module fail, two fans out of the six total available fail, or a complete single fan module is pulled. If a single fan in the fan module fails, the other existing fan will speed up to maintain proper air flow through the SPE. Once the fan module is pulled for replacement, two minutes are allowed before the array shuts down for thermal reasons. These two minutes allows for fan module replacement. Introduction to the CX700 16

VMware with CLARiiON. Sheetal Kochavara

VMware with CLARiiON. Sheetal Kochavara VMware with CLARiiON Sheetal Kochavara Agenda Overview of CLARiiON hardware and software products Integration of CLARiiON with VMware Use Cases of CLARiiON replication software with VMware EMC CLARiiON

More information

EMC SAN Copy Command Line Interfaces

EMC SAN Copy Command Line Interfaces EMC SAN Copy Command Line Interfaces REFERENCE P/N 069001189 REV A13 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2008 EMC Corporation. All

More information

EMC CLARiiON CX3 Series FCP

EMC CLARiiON CX3 Series FCP EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2008

More information

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007 Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange Server Enabled by MirrorView/S and Replication Manager Reference Architecture EMC

More information

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15 EMC SAN Copy Command Line Interface (CLI) Reference P/N 069001189 REV A15 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2010 EMC Corporation.

More information

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Backup and Recovery for Microsoft Exchange 2007 EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

INFOBrief. Dell/EMC CX Family Fibre Channel Storage Systems. Key Points

INFOBrief. Dell/EMC CX Family Fibre Channel Storage Systems. Key Points INFOBrief Dell/EMC CX Family Fibre Channel Storage Systems CX300, CX500, and CX700 Storage Arrays and the DAE2P with UltraPoint Technology Performance, enterprise-class data protection, and scalability

More information

Reference Architecture

Reference Architecture EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 in VMware ESX Server EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com

More information

HIGHLIGHTS. EMC CLARiiON CX4 Series

HIGHLIGHTS. EMC CLARiiON CX4 Series Page 1 of 20 The CLARiiON CX4 series is a scalable, dual controller system with varying amounts of cache, processor cores, disk drives and interfaces. As a storage system, the CLARiiON has had a long and

More information

AX150-Series Upgrading FLARE Operating Environment Software March 28, 2006

AX150-Series Upgrading FLARE Operating Environment Software March 28, 2006 AX150-Series Upgrading FLARE Operating Environment Software March 28, 2006 This document describes how to upgrade your AX150 FLARE Operating Environment (OE) - the storage-system software that includes

More information

EMC SAN Copy Command Line Interface P/N REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA

EMC SAN Copy Command Line Interface P/N REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA EMC SAN Copy Command Line Interface P/N 069001189 REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2009 EMC Corporation. All rights reserved.

More information

EMC Symmetrix DMX Series The High End Platform. Tom Gorodecki EMC

EMC Symmetrix DMX Series The High End Platform. Tom Gorodecki EMC 1 EMC Symmetrix Series The High End Platform Tom Gorodecki EMC 2 EMC Symmetrix -3 Series World s Most Trusted Storage Platform Symmetrix -3: World s Largest High-end Storage Array -3 950: New High-end

More information

EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005

EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005 EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005 Best Practices Planning Abstract This technical white paper explains best practices associated with Microsoft SQL Server 2000

More information

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange in a VMware Environment Enabled by MirrorView/S Reference Architecture EMC Global

More information

EMC CLARiiON Asymmetric Active/Active Feature (ALUA)

EMC CLARiiON Asymmetric Active/Active Feature (ALUA) A Detailed Review Abstract This white paper provides an overview of the EMC CLARiiON Asymmetric Active/Active feature. It highlights the configuration, best practices, implementation details of EMC PowerPath,

More information

Release Notes P/N REV A03 January 3, 2006

Release Notes P/N REV A03 January 3, 2006 Sun StorEdge Traffic Manager for CLARiiON Release Notes P/N 300-002-978 REV A03 January 3, 2006 These release notes contain supplemental information about Sun StorEdge Traffic Manager for CLARiiON storage

More information

DELL EMC UNITY: HIGH AVAILABILITY

DELL EMC UNITY: HIGH AVAILABILITY DELL EMC UNITY: HIGH AVAILABILITY A Detailed Review ABSTRACT This white paper discusses the high availability features on Dell EMC Unity purposebuilt solution. October, 2017 1 WHITE PAPER The information

More information

Disk and FLARE OE Matrix P/N REV A17 February 22, 2011

Disk and FLARE OE Matrix P/N REV A17 February 22, 2011 EMC CX4 Series Storage Systems Disk and FLARE OE Matrix P/N 300-007-437 REV A17 February 22, 2011 To function properly, disks in an EMC CLARiiON system require that each storage processor run minimum revisions

More information

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary v1.0 January 8, 2010 Introduction This guide describes the highlights of a data warehouse reference architecture

More information

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3. EMC Backup and Recovery for Microsoft Exchange 2007 SP1 Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.5 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

Release Notes P/N REV A04 July 7, 2006

Release Notes P/N REV A04 July 7, 2006 cre EMC CX-Series SnapView For FLARE OE Version 02.19.yyy Release Notes P/N 300-002-753 REV A04 July 7, 2006 These release notes contain supplemental information about the following EMC products: SnapView

More information

INFOBrief. Dell EMC CX500 Fibre Channel Storage System. Key Points

INFOBrief. Dell EMC CX500 Fibre Channel Storage System. Key Points INFOBrief Dell EMC CX500 Fibre Channel Storage System By matching high availability features, performance and scalability needs, the Dell/EMC CX500 storage system is an ideal solution for customers looking

More information

INTRODUCTION TO THE EMC VNX2 SERIES

INTRODUCTION TO THE EMC VNX2 SERIES White Paper INTRODUCTION TO THE EMC VNX2 SERIES A Detailed Review Abstract This white paper introduces the EMC VNX2 series platform. It discusses the different models, new and improved features, and key

More information

EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S

EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S Enterprise Solutions for Microsoft SQL Server 2005 EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S Reference Architecture EMC Global Solutions

More information

SAN Storage Array Workbook September 11, 2012

SAN Storage Array Workbook September 11, 2012 Page 1 of 9 The following are questions to be asked regarding acquiring SAN Storage Arrays. Some of the questions need to be filled in for the specific environment where the storage system will be deployed

More information

Disk Storage Systems. Module 2.5. Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved. Disk Storage Systems - 1

Disk Storage Systems. Module 2.5. Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved. Disk Storage Systems - 1 Disk Storage Systems Module 2.5 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 1 Disk Storage Systems After completing this module, you will be able to: Describe the components of an

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS STORAGE CENTER DATASHEET STORAGE CENTER TECHNICAL SPECIFICATIONS Storage Center goes beyond the boundaries of traditional storage systems by combining modular standards-based hardware

More information

EMC CLARiiON Backup Storage Solutions

EMC CLARiiON Backup Storage Solutions Engineering White Paper Backup-to-Disk Guide with Computer Associates BrightStor ARCserve Backup Abstract This white paper describes how to configure EMC CLARiiON CX series storage systems with Computer

More information

Vendor: EMC. Exam Code: E Exam Name: CLARiiON Installation and Troubleshooting Specialist. Version: Demo

Vendor: EMC. Exam Code: E Exam Name: CLARiiON Installation and Troubleshooting Specialist. Version: Demo Vendor: EMC Exam Code: E20-611 Exam Name: CLARiiON Installation and Troubleshooting Specialist Version: Demo Question No : 1 On a CLARiiON CX4-480 array what is the maximum number of drives supported on

More information

Introduction to NetApp E-Series E2700 with SANtricity 11.10

Introduction to NetApp E-Series E2700 with SANtricity 11.10 d Technical Report Introduction to NetApp E-Series E2700 with SANtricity 11.10 Todd Edwards, NetApp March 2014 TR-4275 1 Introduction to NetApp E-Series E2700 with SANtricity 11.10 TABLE OF CONTENTS 1

More information

EMC Fibre Channel Storage System CX-Series CONFIGURATION PLANNING GUIDE P/N REV A02

EMC Fibre Channel Storage System CX-Series CONFIGURATION PLANNING GUIDE P/N REV A02 EMC Fibre Channel Storage System CX-Series CONFIGURATION PLANNING GUIDE P/N 014003113 REV A02 EMC Corporation 171 South Street Hopkinton, MA 01748-9103 Corporate Headquarters: (508) 435-1000, (800) 424-EMC2

More information

Service Description Remote Yearly Maintenance of a Dell EMC Storage Array Environment

Service Description Remote Yearly Maintenance of a Dell EMC Storage Array Environment Service Description Remote early Maintenance of a Dell EMC Storage Array Environment Service SKUs See Appendix A for further information on T1, T2 and T3 Standard Maintenance. Service Overview This service

More information

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions Hardware Announcement February 17, 2003 IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions Overview The IBM TotalStorage FAStT900 Storage Server expands the family

More information

Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage

Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage By Dave Jaffe Dell Enterprise Technology Center and Kendra Matthews Dell Storage Marketing Group Dell Enterprise Technology Center delltechcenter.com

More information

Drive and FLARE OE Matrix

Drive and FLARE OE Matrix EMC CX4 Series Storage Systems and FLARE OE Matrix P/ N 300-007-437 To function properly, drives in an EMC CLARiiON system require that each storage processor run minimum s of the FLARE Operating Environment

More information

EMC CLARiiON CX3-20f Setup Guide P/N REV. A02

EMC CLARiiON CX3-20f Setup Guide P/N REV. A02 EMC CLRiiON CX3-20f Setup Guide P/N 300-004-207 REV. 02 Notice Copyright 2006-2007 EMC Corporation. ll rights reserved. Published July, 2007 EMC believes the information in this publication is accurate

More information

PRACTICE CONSIDERATIONS FOR DELL/EMC CX3 FC/iSCSI STORAGE SYSTEMS

PRACTICE CONSIDERATIONS FOR DELL/EMC CX3 FC/iSCSI STORAGE SYSTEMS Third-party information provided to you courtesy of Dell. PRACTICE CONSIDERATIONS FOR DELL/EMC CX3 FC/iSCSI STORAGE SYSTEMS BEST PRACTICES PLANNING Abstract This white paper discusses practice considerations

More information

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Applied Technology Abstract This white paper describes tests in which Navisphere QoS Manager and VMware s Distributed

More information

Storage Area Networks SAN. Shane Healy

Storage Area Networks SAN. Shane Healy Storage Area Networks SAN Shane Healy Objective/Agenda Provide a basic overview of what Storage Area Networks (SAN) are, what the constituent components are, and how these components fit together to deliver

More information

Hewlett-Packard StorageWorks Enterprise Virtual Array

Hewlett-Packard StorageWorks Enterprise Virtual Array April Adams Product Report 16 July 2003 Hewlett-Packard StorageWorks Enterprise Virtual Array Summary In April 2003, HP introduced a new Enterprise Virtual Array model that will replace most of its EMA/MA

More information

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow

More information

Exchange 2003 Archiving for Operational Efficiency

Exchange 2003 Archiving for Operational Efficiency Exchange 2003 Archiving for Operational Efficiency Enabled by EmailXtender Reference Architecture EMC Global Solutions Operations EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000

More information

Best Practices for deploying VMware ESX 3.x and 2.5.x server with EMC Storage products. Sheetal Kochavara Systems Engineer, EMC Corporation

Best Practices for deploying VMware ESX 3.x and 2.5.x server with EMC Storage products. Sheetal Kochavara Systems Engineer, EMC Corporation Best Practices for deploying VMware ESX 3.x and 2.5.x server with EMC Storage products Sheetal Kochavara Systems Engineer, EMC Corporation Agenda Overview of EMC Hardware and Software Best practices with

More information

INFOBrief. Dell EMC CX700 Fibre Channel Storage System. Key Points

INFOBrief. Dell EMC CX700 Fibre Channel Storage System. Key Points INFOBrief Dell EMC CX700 Fibre Channel Storage System Key Points The Dell/EMC CX700 is specifically designed to match your organizations most demanding applications. Whether messaging, media or database

More information

HP Supporting the HP ProLiant Storage Server Product Family.

HP Supporting the HP ProLiant Storage Server Product Family. HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication

More information

EMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005

EMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005 Enterprise Solutions for Microsoft SQL Server 2005 EMC CLARiiON CX3-80 EMC Long Distance Recovery for SQL Server 2005 Enabled by Replication Manager and RecoverPoint CRR Reference Architecture EMC Global

More information

DELL TM AX4-5 Application Performance

DELL TM AX4-5 Application Performance DELL TM AX4-5 Application Performance A Comparison of Entry-level Storage Platforms Abstract This paper compares the performance of the Dell AX4-5 with the performance of similarly configured IBM DS3400

More information

A Look at CLARiiON with ATA CX Series Disk Drives and Enclosures

A Look at CLARiiON with ATA CX Series Disk Drives and Enclosures A Look at CLARiiON with ATA CX Series Disk Drives and Enclosures Applied Technology Abstract As the need for data storage continues to grow, developing lower-cost storage devices becomes imperative. This

More information

IBM TotalStorage Enterprise Storage Server (ESS) Model 750

IBM TotalStorage Enterprise Storage Server (ESS) Model 750 A resilient enterprise disk storage system at midrange prices IBM TotalStorage Enterprise Storage Server (ESS) Model 750 Conducting business in the on demand era demands fast, reliable access to information

More information

Service Description: Dell EMC Maintenance Service Standard

Service Description: Dell EMC Maintenance Service Standard Dell Services Service Description: Dell EMC Maintenance Service Standard Service SKUs See Appendix A for further information on T1, T2 and T3 Standard Maintenance. Service Overview This service provides

More information

Dell/EMC CX3 Series Oracle RAC 10g Reference Architecture Guide

Dell/EMC CX3 Series Oracle RAC 10g Reference Architecture Guide White Paper Third-party Information Provided to You Courtesy of Dell Dell/EMC CX3 Series Oracle RAC 10g Reference Architecture Guide Abstract This document provides an overview of the architecture of the

More information

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. 1 This training module is divided in six main chapters.

More information

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05 EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006

More information

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results Dell Fluid Data solutions Powerful self-optimized enterprise storage Dell Compellent Storage Center: Designed for business results The Dell difference: Efficiency designed to drive down your total cost

More information

EMC VPLEX with Quantum Stornext

EMC VPLEX with Quantum Stornext White Paper Application Enabled Collaboration Abstract The EMC VPLEX storage federation solution together with Quantum StorNext file system enables a stretched cluster solution where hosts has simultaneous

More information

EMC Virtual Infrastructure for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120 and VMware vsphere 4.0 using iscsi

EMC Virtual Infrastructure for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120 and VMware vsphere 4.0 using iscsi EMC Virtual Infrastructure for Microsoft Exchange 27 Enabled by EMC CLARiiON CX4-12 and Applied Technology Abstract This white paper details a solution built and tested using EMC CLARiiON CX4-12 and VMware

More information

Dell/EMC CX3 Family Fibre Channel Storage Systems

Dell/EMC CX3 Family Fibre Channel Storage Systems INFOBrief Dell/EMC CX3 Family Fibre Channel Storage Systems CX3-10c, CX3-20, CX3-40, and CX3-80 Storage Arrays and the DAE4P with UltraPoint Technology The 3 rd Generation of CX Storage Arrays providing

More information

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS Applied Technology Abstract This white paper describes tests in which Navisphere QoS Manager and

More information

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers By Todd Muirhead Dell Enterprise Technology Center Dell Enterprise Technology Center dell.com/techcenter

More information

EMC CLARiiON CX3 UltraScale Series The Proven Midrange Storage

EMC CLARiiON CX3 UltraScale Series The Proven Midrange Storage EMC CLARiiON CX3 UltraScale Series The Proven Midrange Storage Erez Etzyon Senior Technology Consultant CLARiiON CX3 UltraScale Series Breakthrough Architecture and Innovation Designed to Deliver New Levels

More information

Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems

Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems Applied Technology Abstract This white paper is an overview of Power Vault operation in EMC Symmetrix DMX-3 and Symmetrix DMX-4 environments.

More information

EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution. Enabled by EMC Celerra and Linux using FCP and NFS. Reference Architecture

EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution. Enabled by EMC Celerra and Linux using FCP and NFS. Reference Architecture EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution Enabled by EMC Celerra and Linux using FCP and NFS Reference Architecture Copyright 2009 EMC Corporation. All rights reserved. Published

More information

EMC CLARiiON LUN Shrinking with Microsoft Exchange 2007

EMC CLARiiON LUN Shrinking with Microsoft Exchange 2007 EMC CLARiiON LUN Shrinking with Microsoft Exchange 2007 Applied Technology Abstract This white paper discusses the EMC CLARiiON LUN shrinking feature in detail. It captures the business benefits and advantages

More information

EMC Virtual Infrastructure for Microsoft Exchange 2007

EMC Virtual Infrastructure for Microsoft Exchange 2007 EMC Virtual Infrastructure for Microsoft Exchange 2007 Enabled by EMC Replication Manager, EMC CLARiiON AX4-5, and iscsi Reference Architecture EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103

More information

Rackable 24 Slot Expansion B21 See text for FC hubs, FC switches, platform software, host adapters, disks and options for complete solutions.

Rackable 24 Slot Expansion B21 See text for FC hubs, FC switches, platform software, host adapters, disks and options for complete solutions. M ODELS RA8000 Fibre Channel Fibre Channel Storage solution with industry-leading storage area network (SAN) support uses arbitrated loop (FC-AL) and the latest switched fabric (FC- SW) technology. It

More information

MIGRATING TO DELL EMC UNITY WITH SAN COPY

MIGRATING TO DELL EMC UNITY WITH SAN COPY MIGRATING TO DELL EMC UNITY WITH SAN COPY ABSTRACT This white paper explains how to migrate Block data from a CLARiiON CX or VNX Series system to Dell EMC Unity. This paper outlines how to use Dell EMC

More information

Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated

Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated EMC Solutions for Microsoft Exchange 2007 Virtual Exchange 2007 in a VMware ESX Datastore with a VMDK File Replicated Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated EMC Commercial

More information

Acer Hitachi AMS2300 specifications

Acer Hitachi AMS2300 specifications Product overview For mid-sized and larger businesses, Acer Hitachi Adaptable Modular Storage 2300 is an easy-to-use, scalable, cost-effective storage system for Microsoft Exchange Server, VMware, databases

More information

DELL Reference Configuration Microsoft SQL Server 2008 Fast Track Data Warehouse

DELL Reference Configuration Microsoft SQL Server 2008 Fast Track Data Warehouse DELL Reference Configuration Microsoft SQL Server 2008 Fast Track Warehouse A Dell Technical Configuration Guide base Solutions Engineering Dell Product Group Anthony Fernandez Jisha J Executive Summary

More information

Technical Note P/N REV A01 March 29, 2007

Technical Note P/N REV A01 March 29, 2007 EMC Symmetrix DMX-3 Best Practices Technical Note P/N 300-004-800 REV A01 March 29, 2007 This technical note contains information on these topics: Executive summary... 2 Introduction... 2 Tiered storage...

More information

PeerStorage Arrays Unequalled Storage Solutions

PeerStorage Arrays Unequalled Storage Solutions Simplifying Networked Storage PeerStorage Arrays Unequalled Storage Solutions John Joseph, VP of Marketing EqualLogic,, 9 Townsend West, Nashua NH 03063 Phone: +1-603 603-249-7772, FAX: +1-603 603-579-6910

More information

EMC Business Continuity for Microsoft Applications

EMC Business Continuity for Microsoft Applications EMC Business Continuity for Microsoft Applications Enabled by EMC Celerra, EMC MirrorView/A, EMC Celerra Replicator, VMware Site Recovery Manager, and VMware vsphere 4 Copyright 2009 EMC Corporation. All

More information

IBM System Storage DS6800

IBM System Storage DS6800 Enterprise-class storage in a small, scalable package IBM System Storage DS6800 Highlights Designed to deliver Designed to provide over enterprise-class functionality, 1600 MBps performance for with open

More information

NEC Express5800/ft series

NEC Express5800/ft series Fault Tolerant Server ft series The ultimate choice for business continuity NEC Express5800 fault tolerant servers Fully redundant components are highly resistant to failures. High-availability servers

More information

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions A comparative analysis with PowerEdge R510 and PERC H700 Global Solutions Engineering Dell Product

More information

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM EMC SYMMETRIX VMAX 40K STORAGE SYSTEM The EMC Symmetrix VMAX 40K storage system delivers unmatched scalability and high availability for the enterprise while providing market-leading functionality to accelerate

More information

Parts Location Guide P/N Rev 01

Parts Location Guide P/N Rev 01 EMC VNX Family VNX5100 Parts Location Guide P/N 300-013-312 Rev 01 June 26, 2012 This guide describes one of five models available in the VNX Series, the EMC VNX5100. This guide is a parts location guide

More information

EMC VPLEX Geo with Quantum StorNext

EMC VPLEX Geo with Quantum StorNext White Paper Application Enabled Collaboration Abstract The EMC VPLEX Geo storage federation solution, together with Quantum StorNext file system, enables a global clustered File System solution where remote

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER ANNEX II + III : TECHNICAL SPECIFICATIONS + TECHNICAL OFFER Contract title : Supply of Information & Communication Technology Hardware Publication reference: 2017/386304 10/1/1.1/1.2.2a p 1 / Columns 1-2

More information

EMC SYMMETRIX VMAX 10K

EMC SYMMETRIX VMAX 10K EMC SYMMETRIX VMAX 10K EMC Symmetrix VMAX 10K with the Enginuity operating environment delivers a multi-controller, scale-out architecture with consolidation and efficiency for the enterprise. The VMAX

More information

HP P6000 Enterprise Virtual Array

HP P6000 Enterprise Virtual Array HP P6000 Enterprise Virtual Array The HP P6000 Enterprise Virtual Array (P6000 EVA) is an enterprise class virtual storage array family for midsized organizations at an affordable price. With built in

More information

Terminology. This document uses the following terms:

Terminology. This document uses the following terms: CX4 Architecture for NS Series Connecting a CX4-48 Storage System in a Fibre Channel Direct or Switch Configuration with a Microsoft Windows Server with Native Multipath Failover December 6, 28 If you

More information

Assessing performance in HP LeftHand SANs

Assessing performance in HP LeftHand SANs Assessing performance in HP LeftHand SANs HP LeftHand Starter, Virtualization, and Multi-Site SANs deliver reliable, scalable, and predictable performance White paper Introduction... 2 The advantages of

More information

StorageTek D Series Disk Subsystems

StorageTek D Series Disk Subsystems April Adams Product Report 5 November 2003 D Series Disk s Summary In September 2003, added a new model to its line of midrange, Fibre Channel storage s. The D240 Disk scales up to 16.4TB, filling the

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!   We offer free update service for one year PASS4TEST IT Certification Guaranteed, The Easy Way! \ http://www.pass4test.com We offer free update service for one year Exam : E20-822 Title : CLARiiON Solutions Expert Exam for Storage Administrators

More information

EMC SYMMETRIX VMAX 40K SYSTEM

EMC SYMMETRIX VMAX 40K SYSTEM EMC SYMMETRIX VMAX 40K SYSTEM The EMC Symmetrix VMAX 40K storage system delivers unmatched scalability and high availability for the enterprise while providing market-leading functionality to accelerate

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

EMC Celerra NS-120 System (Dual Blade) Installation Guide

EMC Celerra NS-120 System (Dual Blade) Installation Guide EMC Celerra NS- System (Dual Blade) Installation Guide P/N -7-88 Rev A EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without

More information

3.1. Storage. Direct Attached Storage (DAS)

3.1. Storage. Direct Attached Storage (DAS) 3.1. Storage Data storage and access is a primary function of a network and selection of the right storage strategy is critical. The following table describes the options for server and network storage.

More information

IOPStor: Storage Made Easy. Key Business Features. Key Business Solutions. IOPStor IOP5BI50T Network Attached Storage (NAS) Page 1 of 5

IOPStor: Storage Made Easy. Key Business Features. Key Business Solutions. IOPStor IOP5BI50T Network Attached Storage (NAS) Page 1 of 5 IOPStor: Storage Made Easy Application data, virtual images, client files, email, the types of data central to running a successful business can seem endless. With IOPStor you finally have an advanced

More information

IBM System Storage DS4800

IBM System Storage DS4800 Scalable, high-performance storage for on demand computing environments IBM System Storage DS4800 Highlights 4 Gbps Fibre Channel interface Includes IBM System Storage technology DS4000 Storage Manager

More information

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

Lot # 10 - Servers. 1. Rack Server. Rack Server Server 1. Rack Server Rack Server Server Processor: 1 x Intel Xeon E5 2620v3 (2.4GHz/6 core/15mb/85w) Processor Kit. Upgradable to 2 CPU Chipset: Intel C610 Series Chipset. Intel E5 2600v3 Processor Family. Memory:

More information

Technical Note. Dell/EMC Solutions for Microsoft SQL Server 2005 Always On Technologies. Abstract

Technical Note. Dell/EMC Solutions for Microsoft SQL Server 2005 Always On Technologies. Abstract Technical Note Dell/EMC Solutions for Microsoft SQL Server 2005 Always On Technologies Abstract This technical note provides information on the Dell/EMC storage solutions, based on the Microsoft SQL Server

More information

Release Notes P/N REV A05 July 7, 2006

Release Notes P/N REV A05 July 7, 2006 EMC CX-Series SAN Copy for FLARE OE Version 02.19.yyy Release Notes P/N 300-002-755 REV A05 July 7, 2006 These release notes contain supplemental information about the following EMC products: EMC SAN Copy

More information

EMC Business Continuity for Oracle Database 11g

EMC Business Continuity for Oracle Database 11g EMC Business Continuity for Oracle Database 11g Enabled by EMC Celerra using DNFS and NFS Copyright 2010 EMC Corporation. All rights reserved. Published March, 2010 EMC believes the information in this

More information

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment. The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment. IPMI Control Dual Power Supplies Enhanced Metadata Uptime Storage Up to 1.3M IOPS and 5,500 MBps throughput

More information

EMC Celerra NS20. EMC Solutions for Microsoft Exchange Reference Architecture

EMC Celerra NS20. EMC Solutions for Microsoft Exchange Reference Architecture EMC Solutions for Microsoft Exchange 2007 EMC Celerra NS20 EMC NAS Product Validation Corporate Headquarters Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2008 EMC Corporation. All rights

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

SMART SERVER AND STORAGE SOLUTIONS FOR GROWING BUSINESSES

SMART SERVER AND STORAGE SOLUTIONS FOR GROWING BUSINESSES Jan - Mar 2009 SMART SERVER AND STORAGE SOLUTIONS FOR GROWING BUSINESSES For more details visit: http://www-07preview.ibm.com/smb/in/expressadvantage/xoffers/index.html IBM Servers & Storage Configured

More information