1 Disk Storage Systems Module EMC Corporation. All rights reserved. Disk Storage Systems - 1

2 Disk Storage Systems After completing this module, you will be able to: Describe the components of an intelligent storage system Describe the configuration of a logical disk Discuss the methods employed to ensure that a host can access a storage volume Discuss back end volume protection Discuss front end host configuration Describe the I/O flow from the back end to the physical disks 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 2 At this point, you have learned how disks work and how they can be combined to form arrays, otherwise known as RAID sets. Now we are going to build on those concepts and add intelligence to those arrays, making them even more powerful. Throughout this module we will refer to this as an intelligent storage system. Disk Storage Systems - 2

3 Lesson: Intelligent Storage System Overview After completing this lesson, you will be able to: List the benefits of intelligent storage systems Compare and contrast integrated and modular approaches to intelligent storage systems Describe the I/O flow through the storage system Describe the logical elements of an intelligent storage system 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 3 In this lesson, we will take a high level look at the components of a disk storage system as well as two approaches to implementing them: integrated and modular. Disk Storage Systems - 3

4 What is an Intelligent Storage System? A disk storage system which distributes data over several devices and manages access to that data. When implemented properly, it provides the following benefits over individual storage devices: Increased capacity Improved performance Easier data management Better data availability More robust backup/restore capabilities Improved flexibility and scalability 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 4 The benefits of an intelligent storage system are shown above. Performance is one of the most important benefits. Vendors are continually working to improve performance and heavily market their performance numbers. Disk Storage Systems - 4

5 Monolithic (Integrated) Storage Systems FC Ports Port Processors Monolithic Cache RAID Controllers 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 5 Arrays generally fall into one of two categories, monolithic and modular. Monolithic storage systems are generally aimed at the enterprise level, centralizing data in a powerful system with hundreds of drives. They have the following characteristics: Large storage capacity Large amounts of cache to temporarily store I/Os before writing to disk Redundant components for improved data protection and availability Many built in features to make them more robust and fault tolerant Usually connect to mainframes or very powerful open systems hosts Multiple front end ports to provide connectivity to multiple servers Multiple back end Fibre Channel or SCSI RAID controllers to manage disk processing. Expensive This system is contained within a single frame or interconnected frames (for expansion) and can scale to support increases in connectivity, performance, and capacity as required. Monolithic storage devices can handle large amounts of concurrent I/Os on very large data applications. However, they have high upfront costs limiting their applicability to only the most mission critical applications. They also take up a large amount of space in the data center. Note: Monolithic arrays are sometimes called integrated arrays, enterprise arrays, or cache centric arrays. Disk Storage Systems - 5

6 Modular Storage Systems Modular Host Interface Cache RAID Controller A Host Interface Cache RAID Controller B Rack Servers FC Switches Disk Modules Control Module with Disks 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 6 Modular storage systems provide storage to a smaller number of (typically) Windows or Unix servers than larger integrated storage systems. Modular storage systems are typically designed with two controllers, each of which contains host interfaces, cache, RAID processors, and disk drive interfaces. They have the following characteristics: Small companies/department level Smaller disk capacity and less global cache Takes up less floor space and costs less Can start with a smaller number of disks and scale as needed Fewer front end ports for connection to servers Performance can degrade as capacity increases Cannot connect to mainframes Limited redundancy and connectivity Usually have separate controllers from the disk array Note: Modular storage systems are sometimes called midrange or departmental storage systems. Disk Storage Systems - 6

7 Elements in an Intelligent Storage System Intelligent Storage System Front End Back End Physical Disks Host Connectivity Cache Cache 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 7 Intelligent storage systems are organized into the following areas: Front End Cache Back End Physical disks Disk Storage Systems - 7

8 Intelligent Storage System: Front End Intelligent Storage System Front End Back End Physical Disks Host Connectivity Cache Ports Controllers Note: Include redundancy in the channels to and from the ports EMC Corporation. All rights reserved. Disk Storage Systems - 8 The front end provides the communication from the storage system to the host. Front end ports connect to the hosts in the environment. Ports are the external interfaces for connectivity to the host. Each storage port has processing logic responsible for executing the appropriate transport protocol for storage connections. For example, it could use SCSI, Fibre Channel, or iscsi. Behind the storage ports are controllers which route the data to the cache via the internal data bus. As soon as the cache receives the data, the controller can send an acknowledgement message back to the host. Note: To maintain data availability, the front end of the storage systems generally have multiple ports. This provides redundancy in case of a failure, and also helps to balance the load when the system is experiencing heavy use. The number of front-end ports on a midrange storage system generally ranges from 1-8; 4 is typical. On a large monolithic array, port counts as high as 64 or 128 are common. Disk Storage Systems - 8

9 Front End Command Queuing Without Command Queuing Request 1 Request 2 Request 3 Request 4 F R O N T E N D With Command Queuing Request 1 Request 2 Request 3 Request 4 F R O N T E N D EMC Corporation. All rights reserved. Disk Storage Systems - 9 As we have seen earlier, command queuing processes multiple concurrent commands based on the organization of the data on disk, regardless of the order in which the commands were received. The command queuing software will reorder commands so as to make the execution more efficient, and will assign each command a tag. This tag identifies when the command will be executed, just as the number you take at the deli determines when you will be served. Some disk drives, particularly SCSI and Fibre Channel disks, are intelligent enough to manage their own command queuing. Intelligent storage systems may make use of this native disk intelligence, and may supplement it with queuing performed by the controller. There are several command queuing algorithms that can be used. Here are some of the common ones. First In, First Out commands are executed in the order in which they arrive. This is identical to having no queuing, and is therefore inefficient in terms of performance. Seek Time Optimization - faster than First In, First Out. However, two requests could be on cylinders that are very close to each other, but in very different places within the track. Meanwhile, there might be a third sector that is a few cylinders further away but much closer overall to the location of the first request. Optimizing seek times only, without regard for rotational latency, will not normally produce the best results. Access Time Optimization - combines seek time optimization with an analysis of rotational latency for optimal performance. Note: The Queue Depth Setting defines the number of outstanding requests that are active (in the queue) at the same time. Many manufactures have configurable queue depths. Disk Storage Systems - 9

10 Intelligent Storage System: Cache Intelligent Storage System Front End Back End Physical Disks Host Connectivity Cache 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 10 Cache is very fast memory that improves system performance by isolating the hosts from the mechanical delays associated with physical disks. You have already seen that accessing data from a physical disk usually takes several milliseconds, because of seek times and rotational latency; accessing data from high speed memory will typically take less than a millisecond. The performance of reads as well as writes may be improved by the use of cache. Cache is discussed in more detail in the next lesson. Disk Storage Systems - 10

11 Intelligent Storage System: Back End Intelligent Storage System Front End Back End Physical Disks Host Connectivity Cache Controllers Ports 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 11 When data gets transferred from the cache, it is sent through the I/O bus to the back end, where it is routed to the correct drive. The back end provides the communication with the disks for read and write operations. Back end functionality is generally provided by disk controllers. The disk controller: Manages the transfer of data between the I/O bus and the disks in the storage system Handles addressing for the device, translating logical blocks into physical locations on the disk Provides additional, but limited, temporary storage for data Provides error detection and correction often in conjunction with similar features on the disks Allows multiple devices to communicate to the Host Bus Adapter (HBA) on the host Facilitates performance enhancement Disk controllers are implemented as hardware (with firmware a built-in program) that communicates with the disks via the disk interface, sending commands to initiate the read/write process on the disks. The design of the controller is vendor specific. To provide maximum data protection and availability, dual controllers provide an alternative path in case of a failure. This reliability is enhanced if the disks used are dual-ported; each disk port can connect to a separate controller. Having multiple controllers will also facilitate load balancing. Having more than one port on each controller will provide additional protection in the event of certain types of failure. Disk Storage Systems - 11

12 Intelligent Storage System: Physical Disks Intelligent Storage System Front End Back End Physical Disks Host Connectivity Cache 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 12 Physical disks are where the storage actually takes place. This could be a single disk drive or a more complex RAID set. Drives are connected to the controller with either SCSI (SCSI interface and copper cable) or Fibre Channel (optical or copper) cables. When a storage system is used in environments where performance is not critical, ATA drives may be used. The connection to the drives will then be made via parallel ATA (PATA) or serial ATA (SATA) copper cables. Some storage systems allow a mixture of SCSI or Fibre Channel drives and ATA drives. The higher performing drives are used for application data storage, while the slower ATA drives are used for backup and archiving. Disk Storage Systems - 12

13 I/O Example: Read Requests Intelligent Storage System Front End Back End Physical Disks Host Connectivity Cache 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 13 To read data from disk: 1. The host sends a read request which is routed to the appropriate drive. 2. The disk drive locates the information by positioning the read/write head at the specified location on the disk platter. 3. The information is read from the disk and sent back to the host. If the data was not found, or if it was damaged, the drive will return the appropriate error status via a message sent to the controller. 4. The host verifies that the data arrived properly (without errors) meaning no bits lost to power spikes, line noise on the bus, or other hardware related failures, and makes use of the data. Since requests for data can occur much more quickly than data can be physically retrieved from disk, an intelligent storage system uses caching to predict what information on the disk will be needed in the near future, and load it into cache before the host requests it. This helps to reduce I/O bottlenecks in the system. Disk Storage Systems - 13

14 I/O Example: Write Requests Intelligent Storage System Front End Back End Physical Disks Host Connectivity Cache 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 14 To write data to disk: 1. The Host sends the data along with the instruction to write the data at a particular address location. 2. The Host waits for confirmation that the data has been stored, before it replaces the data in main memory with new data. Disk Storage Systems - 14

15 What the Host Sees Intelligent Storage System Host LUN 0 LUN 1 Cache Back End Physical Disks Host LUN 2 LUN 0 LUN 1 LUN EMC Corporation. All rights reserved. Disk Storage Systems - 15 Since intelligent storage systems have multiple disk drives, they use the disks in various ways to provide optimal performance and capacity. For example: A large physical drive could be subdivided into multiple virtual disks of smaller capacity. Several small physical drives can be combined together into a RAID set and presented as one virtual disk. A combination of the above smaller physical drives may be combined into one RAID set, which can then be split into multiple virtual disks, or LUNs With a virtual disk, the physical storage does not change only the way it is represented to the hosts. A Logical Unit Number (LUN) represents the address of the physical disk partition, and is used by the host when accessing disks. The controller uses translation tables to map storage locations on the individual disk drives in the RAID set to locations on the virtual drives that the host sees. These virtual drives are known as logical volumes, or LUNs, and their addressing is independent of the physical disks. Disk Storage Systems - 15

16 The Host and Logical Device Names Host Volume Manager /dev/rdsk/c1t1d0 /dev/rdsk/c1t1d1 LUN 0 LUN 1 Intelligent Storage System Cache Back End Physical Disks Host Volume Manager \\.\PhysicalDrive0 LUN 2 LUN 0 LUN 1 LUN EMC Corporation. All rights reserved. Disk Storage Systems - 16 This example shows a single physical disk divided into 3 LUNs: LUN 0, 1 and 2. The LUNs are presented separately to the host or hosts. A host will see a LUN as if it were a single disk device the physical configuration of the drives is hidden by the storage system. The host assigns logical device names to disk devices; these naming conventions vary by platform. Examples are shown for both Unix and Windows addressing. Disk Storage Systems - 16

17 Disk Organization in a Storage System Intelligent Storage System Host LUN 0 Cache Back End Physical Disks LUN 0 Host LUN 1 LUN EMC Corporation. All rights reserved. Disk Storage Systems - 17 In the previous example, an individual disk was broken up into logical units. The same concept can be applied to entire RAID sets. Here a RAID set consisting of 5 disks has been sliced, or partitioned, into several LUNs. In this example, LUNs 0 and 1are shown. Note how a portion of each LUN resides on each disk in the RAID set. Disk Storage Systems - 17

18 Lesson Summary Key points covered in this lesson: An intelligent disk storage system: Distributes data over several devices and manages access to that data Has a front end, cache, a back end, and physical disks. Use the virtual disks to provide optimal performance and capacity. Individual disks within a RAID set can be divided into logical units. The same concept can be applied to entire RAID sets EMC Corporation. All rights reserved. Disk Storage Systems - 18 Please take a few moments to review the key points covered in this lesson. Disk Storage Systems - 18

19 Lesson: Cache A Closer Look After completing this lesson, you will be able to: Define cache Distinguish between multipurpose cache and configurable cache Describe cache hits and misses Describe algorithms to manage cache Trace the I/O flow from the cache to the back end to the physical disks 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 19 We already mentioned that cache plays a key role in an intelligent storage system. At this point, let s take a closer look at what cache is and how it works. Disk Storage Systems - 19

20 What is Cache in a Storage System A memory space used by a disk storage system to reduce the time required to read data/write data. It is usually made from very fast memory Write Request Read Request Cache Data Acknowledgment 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 20 Cache is very fast memory, which the processor can access more quickly than main memory. Caching is very effective because most programs access the same data repeatedly. In some implementations, multiple applications can hold data in cache simultaneously. Memory in a storage subsystem has two main functions: Staging - temporary buffering of current read and write data for each I/O Caching - repository for frequently accessed data Read cache holds data in anticipation that it will be requested by a client. Write cache holds data written by a client until it can be safely stored on more permanent storage media such as disk or tape. Because cache is memory, it is volatile loss of power will cause memory content, and therefore host data, to be lost. Storage system vendors solve this problem in various ways the memory may be powered by a battery until AC power is restored, or write cache content may be saved to non-volatile storage, such as disk. An additional complication arises on many midrange storage systems, where cache is mirrored (i.e., each controller has exclusive access to its own cache). It needs a mechanism to ensure that cache is coherent, in other words that the two copies of the data are identical. Failover from one controller to another is only reliable if this cache coherency is guaranteed by the design. Disk Storage Systems - 20

21 How Cache is Structured Data Store Tag RAM 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 21 The amount of data that the cache can hold is based on the cache s size and design of the cache. A cache will normally consist of two parts: Data store - the part of the cache that holds the data. Tag RAM the part of the cache that tracks the location of the data in the data store. Entries in this area indicate where the data is found in memory, and also where the data belongs on disk. Additional information found here will include a dirty bit a flag that indicates that data in cache has not yet been committed to disk. There may also be time-based information such as the time of last access. This information will be used to determine which cached information has not been accessed for a long period of time, and may be discarded. In some cases read and write cache reside within the same memory space. This type of cache implementation is referred to as a multipurpose cache. The storage system will determine how much space should be devoted to reads and how much should be devoted to writes. Another implementation allows the user to determine the ratio of read cache to write cache. This cache implementation generally occurs in modular storage systems, since the amount of memory is limited. When large amounts of memory are available, as there is in integrated storage systems, read and write caches often have their own dedicated memory spaces. This type of cache implementation is known as a dedicated cache. Note: You may see references to global cache. This term indicates that there is one cache for the storage system which is shared by all the controllers in that storage system, rather than a separate cache per controller. Disk Storage Systems - 21

22 Read Cache Hits and Misses Data found in cache = Hit Read Request Cache No data found = Miss Read Request Cache 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 22 The processor initiates a memory request that is sensed by the cache controller. The requested address is used to access Tag RAM to determine whether required data is available in cache. When the requested data is found in the cache, it is known as a cache hit. The data is sent directly to the host, with no disk operation required. Besides providing fast response from memory components, cache hits can also shorten the I/O path. I/O processing time will be mostly dependent upon the host, not the array as I/O response time is minimal. When the data is not found in cache, the operation is known as a cache miss. When there is a cache miss, the data must be read from disk. Once the data is retrieved from disk it is moved to the host. It will normally also be placed in cache, as shown in the slide The read cache hit ratio (or hit rate), usually expressed as a percentage, describes how well the read cache is performing. To determine the hit ratio, divide the number of read cache hits by the total number of read requests. Cache misses degrade performance by lengthening the I/O path cache must be searched before the storage system attempts to find the data on disk. The physical task of locating and reading the data from the physical disk takes appreciably longer than a cache hit 5ms or more is typical. Here the I/O response time comprises a larger proportion of the I/O processing time. Note: A read cache hit can take less than a millisecond, while a read cache miss can take many times longer (the actual time depends on many factors). Remember that average disk access times for reads are often in the 10 ms range. Disk Storage Systems - 22

23 Algorithms Used to Manage Read Cache New Data Least Recently Used (LRU) Determines which items are accessed frequently/infrequently Discards least recently used data Oldest Data Read Ahead (pre-fetch) Accesses data sequentially and puts it into cache before it is requested May assume that data recently accessed will not be needed again EMC Corporation. All rights reserved. Disk Storage Systems - 23 Cache has a limited amount of space. Once it is full, the cache controller needs to determine which data will be retained, and which data will be removed to make room for new incoming data. The algorithm used should be based on how the application accesses data for maximum efficiency. Two algorithms commonly used for read cache management are: Least Recently Used (LRU) determines access frequency and discards least recently used data. This algorithm is simple to implement, and will usually allow a high hit ratio. It reflects the access pattern by keeping data which is frequently accessed. Read Ahead (pre-fetch) reads data from disk and puts that data into read cache before it is requested by the host. This operation will be triggered when the cache controller detects data accesses which are sequential. Some implementations assume that data recently accessed will not be needed again, and will discard that data rather than pre-fetched data. Pre-fetching minimizes the time that the host waits for data to be fetched from the storage system. Note: It is inefficient to pre-fetch too much data, so some systems enable you to set a limit for the maximum amount of data which may be pre-fetched. Disk Storage Systems - 23

24 Write Algorithms Write-through Cache Write Request Cache Acknowledgement Write-back Write Request Cache Acknowledgement 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 24 Write-through cache immediately moves data to disk, while retaining a copy in cache. Low performance benefits for writing data; benefits for reads Low risk of data loss Write-back cache keeps data from several write operations in cache and writes the data to disk at some later time. Improves write performance, especially on a busy system Can be risky with regards to data loss. This is why data must be protected from power failures. Disk Storage Systems - 24

25 Write Cache: Performance Manage peak I/O requests bursts through flushing Least-recently used pages are flushed from cache to the drives For maximum performance: Provide headroom in write cache for I/O bursts Coalesce small host writes into larger disk writes Improve sequentiality at the disk 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 25 Some of the things that cache can do to improve performance include: Manage peak I/O requests by absorbing large groups of writes called bursts without becoming bottlenecked by the speed of a physical disk. This is known as burst smoothing. Merging several writes to the same area into a single operation Because write cache is a limited resource, it must be managed carefully, especially in busy environments. The algorithms that manage the flushing of cached data to the disks must be efficient, and should adapt to changing data access patterns. The actual algorithms used are vendor-specific. Disk Storage Systems - 25

26 Lesson Summary Key points covered in this lesson: Cache is a memory space used by a disk storage system to reduce the time required to read data/write data. It can speed up both read and write operations. Cache read algorithms include: Least Recently Used (LRU) Read Ahead (pre-fetch) Cache write algorithms include: Write-through Write-back 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 26 Take a few moments to review the key points covered in this lesson. Disk Storage Systems - 26

27 Module Summary Key points covered in this module: An intelligent disk storage system distributes data over several devices and manages access to that data. Monolithic storage systems are generally aimed at the enterprise level, centralizing data in a powerful system with hundreds of drives. Modular storage systems provide storage to a smaller number of (typically) Windows or Unix servers than larger integrated storage systems. Cache is an important part of intelligent disk storage systems as it can be used to improve performance EMC Corporation. All rights reserved. Disk Storage Systems - 27 Please take a few moments to review the key points covered in this module. Disk Storage Systems - 27

28 Check Your Knowledge What are the parts of an Intelligent Disk Subsystem? What is the difference between a monolithic and a modular array? What is the difference between cache hit and a cache miss? What is the difference between Least Recently Used and Read Ahead cache? What is the difference between Write-through and Writeback cache? 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 28 Disk Storage Systems - 28

29 Apply Your Knowledge Upon completion of this case study, you will be able to: Describe the basic architecture of the CLARiiON modular storage array. Describe the basic architecture of the Symmetrix integrated storage array EMC Corporation. All rights reserved. Disk Storage Systems - 29 At this point, we will apply what you learned in this lesson to some real world examples. In this case, we will look at the architecture of the EMC CLARiiON and EMC Symmetrix storage arrays. Disk Storage Systems - 29

30 CLARiiON CX3-80 Architecture UltraScale Storage Processor Fibre Channel Mirrored cache FC CPU CPU 1/2/4 Gb/s Fibre Channel Front End CLARiiON Messaging Interface (CMI) Multi-Lane PCI-Express bridge link Fan Power supply Fan Fan UltraScale Storage Processor Fibre Channel FC FC FC SPS Power supply FC FC FC FC Fan SPS Mirrored cache CPU CPU 2/4 Gb/s Fibre Channel Back End 4Gb/s LCC 4Gb/s LCC 2/4 Gb/s Fibre Channel Back End 4Gb/s LCC 4Gb/s LCC 4Gb/s LCC 4Gb/s LCC 4Gb/s LCC 4Gb/s LCC Up to 480 drives max per storage system (CX3-80) 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 30 The CLARiiON architecture includes fully redundant, hot swappable components meaning the system can survive the loss of a fan or a power supply, and the failed component can be replaced without powering down the system. The Standby Power Supplies (SPSs) will maintain power to the cache for long enough to allow its content to be copied to a dedicated disk area (called the vault) if a power failure should occur. Storage Processors communicate with each other over the CLARiiON Messaging Interface (CMI) channels. They transport commands, status information, and data for write cache mirroring between the Storage Processors. CMI is used for peer-to-peer communications in the SAN space and may be used for I/O expansion in the NAS space. The CX3-80 uses PCI-Express as the high-speed CMI path. PCI Express architecture delivers advance I/O technology delivering high bandwidth per pin, superior routing characteristics, and improved reliability. When more capacity is required, additional disk array enclosures containing disk modules can be easily added. Link Control Cards (LCC) connect shelves of disks. Disk Storage Systems - 30

31 Assigning CLARiiON LUNs to Hosts CLARiiON disks are grouped into RAID Groups Disks from any enclosure may be used in a RAID Group All disks in a RAID Group must be either Fibre Channel or ATA A RAID Group is the RAID set discussed earlier A RAID Group may be a single disk, or RAID Level 0, 1, 1/0, 3 or 5 The RAID Group is then partitioned into LUNs All LUNs in a RAID Group will be the same RAID Level The LUNs are then made accessible to hosts CLARiiON-resident software ensures that LUNs are seen only by the hosts that own them 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 31 Making LUNs available to a host is a 3-step process: 1. Create a RAID Group Choose which physical disks should be used for the RAID Group and assign those disks to the group. Each physical disk may be part of one RAID Group only. 2. Create LUNs on that RAID Group LUNs may be created (Note: The CLARiiON term is bound ) on that RAID Group. The first LUN that is bound will have a RAID Level selected by the user; all subsequent LUNs must be of the same RAID Level. 3. Assign those LUNs to hosts When LUNs have been bound, they are assigned to hosts. Normal host procedures, such as partitioning, formatting and labeling, will then be performed to make the LUN usable. The CLARiiON software that controls host access to LUNs, a process known as LUN masking, is called Access Logix. Disk Storage Systems - 31

32 Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved. EMC Symmetrix DMX Array y Direct Matrix Interconnect y Dynamic Global Memory y Enginuity Operating Environment y Processing Power y Flexible Back-End Configurations y Fault-tolerant Design 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 32 The Symmetrix DMX series arrays delivers the highest levels of performance and throughput for high-end storage. It incorporates the following features: y Direct Matrix Interconnect Up to 128 direct paths from directors and memory Up to 128 GB/s data bandwidth; up to 6.4 GB/s message bandwidth y Dynamic Global Memory Up to 512 GB Global Memory Intelligent Adaptive Pre-fetch Tag-based cache algorithms y Enginuity Operating Environment Foundation for powerful storage-based functionality Continuous availability and advanced data protection Performance optimization and self-tuning Advanced management Integrated SMI-S compliance y Advanced processing power Up to 130 PowerPC Processors Four or eight processors per director y High-performance back end Up to 64 2 Gb/s Fibre Channel paths (12.8 GB/s maximum bandwidth) RAID 0, 1, 1 + 0, 5 73, 146, and 300 GB 10,000 rpm disks; 73 and 146 GB 15,000 rpm disks; 500 GB 7,200 rpm disks y A fully fault-tolerant design Nondisruptive upgrades and operations Full component-level redundancy with hot-swappable replacements Support: Dual-ported disks and global-disk hot spares Redundant power supplies and integrated battery backups Remote support and proactive call-home capabilities Disk Storage Systems - 32

33 Symmetrix DMX Series Direct Matrix Architecture 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 33 This shows the logical representation of the Symmetrix DMX architecture. The Front-end (host connectivity directors and ports), Cache (Memory) and the Back-end (directors/ports which connect to the physical disks) are shown. Front-end: Hosts connect to the DMX via front-end ports (shown as Host Attach ) on Front-end directors. DMX supports ESCON, FICON, Fibre Channel and iscsi front-end connectivity. Back-end: The disk director ports (back-end) are connected to Disk Array Enclosures. The DMX back-end employs an arbitrated loop design and dual-ported disk drives. I/Os to the physical disks are handled by the backend. Cache: All front-end I/Os (reads and writes) to the Symmetrix have to pass through the cache, this is unlike some arrays which will allow I/Os to by pass cache altogether. Let us take a look at how the Symmetrix handles front-end read and write operations: Read: A read is issued by a server. The Symmetrix will look for the data in the cache, if the data is in cache it will be read from cache and sent to the server via the front-end port This is a read hit. If the data is not in cache, then the Symmetrix will go to the physical disks on the back-end, fetch the data into cache and then send the data from the cache to the requesting server This is a read miss. Write: A write is issued by a sever. The write will be received in cache and a write complete will be immediately issued to the server. Data will be de-staged from the cache to the back-end at a later time. Enhanced global memory technology supports multiple regions and sixteen connections on each global memory director, one to each director. Each director slot port is hard-wired point-to-point to one port on each global memory director board. If a director is removed from a system, the usable bandwidth is not reduced. If a memory board is removed, the usable bandwidth is dropped. Disk Storage Systems - 33

34 Symmetrix DMX: Dual-ported Disk and Redundant Directors Disk Director 1 Disk Director 16 S P S P S P S P P S P S P S P S P = Primary Connection to Drive S= Secondary Connection for Redundancy 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 34 Symmetrix DMX back-end employs an arbitrated loop design and dual-ported disk drives. Each drive connects to two paired Disk Directors through separate Fibre Channel loops. Port Bypass Cards prevent a Director failure or replacement from affecting the other drives on the loop. Directors have four primary loops for normal drive communication and four secondary loops to provide alternate path if the other director fails. Disk Storage Systems - 34

35 Configuring Symmetrix Logical Volumes (SLV) Physical Disk Physical Disk Physical Disk Physical Disk Physical Disk Symmetrix Service Processor Running SymmWin Application Initial configuration of Symmetrix Logical Volumes is done via the Symmetrix Service Processor and the SymmWin interface/application A configuration file (IMPL.BIN) is created and loaded on to the array Subsequent configuration changes can be performed online using EMC ControlCenter (GUI) or by using Solutions Enabler (CLI) 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 35 All Symmetrix Arrays have a Service Processor running the SymmWin application. Initial configuration of Symmetrix Arrays has to be performed by EMC personnel via the Symmetrix Service Processor. Physical disks (in the disk array enclosures) are sliced into hypers or disk slices and protection schemes (RAID1, RAID5 etc.) are then incorporated, creating the Symmetrix Logical Volumes (we will discuss this further in the next slide). A Symmetrix logical volume is the entity that is presented to a host via a Symmetrix front-end port. The host views the Symmetrix Logical volume as a physical drive. Do not confuse Symmetrix Logical Volumes with host-based logical volumes. Symmetrix Logical Volumes are defined by the Symmetrix configuration while Hostbased logical volumes are configured by Logical Volume Manager software. EMC ControlCenter and Solutions Enabler are software packages which are used to monitor and manage the Symmetrix. Solutions Enabler has a Command Line Interface, while ControlCenter provides a Graphical User Interface (GUI). ControlCenter is a very powerful storage management tool Managing the Symmetrix is one of the many things that it can do. Disk Storage Systems - 35

36 RAID1 Symmetrix Logical Volume RAID1 SLV Data is written to two hyper volumes on two different physical disks which are accessed via two different disk directors Host is unaware of data protection being applied Different Disk Disk Director Director Hyper Volumes Physical Drive Logical Volume 04B Host Address Target = 1 LUN = 0 Physical Drive LV 04B M2 LV 04B M EMC Corporation. All rights reserved. Disk Storage Systems - 36 Mirroring provides the highest level of performance and availability for all applications. Mirroring maintains a duplicate copy of a logical volume on two physical drives. The Symmetrix maintains these copies internally by writing all modified data to both physical locations. The mirroring function is transparent to attached hosts, as the hosts view the mirrored pair of hypers as a single Symmetrix logical volume. A RAID1 SLV: Two hyper volumes from two different disks on two different disk directors are logically presented as an RAID1 SLV. The hyper volumes are chosen from different disks on different disk directors to provide maximum redundancy. The SLV is given an Hexadecimal address - In the example SLV 04B is a RAID1 SLV whose hyper volumes exist on the physical disks in the back-end of the array. The SLV is then mapped to one or more Symmetrix front-end ports (a target and LUN ID is assigned at this time). The SLV can now be assigned to a server. The server will view the SLV as a physical drive. On a fully configured Symmetrix DMX3 array one can have up to 64,000 Symmetrix Logical Volumes. The maximum number of SLVs on a DMX is a function of the number of disks, disk directors and the protection scheme used. Disk Storage Systems - 36

37 Data Protection Mirroring (RAID 1) Highest performance, availability and functionality Two hyper mirrors form one Symmetrix Logical Volume located on separate physical drives Parity RAID (Not available on DMX3) 3 +1 (3 data and 1 parity volume) or 7 +1 (7 data and 1 parity volume) Raid 5 Striped RAID volumes Data blocks are striped horizontally across the members of the RAID group ( 4 or 8 member group); parity blocks rotate among the group members RAID 10 Mirrored Striped Mainframe Volumes Dynamic Sparing SRDF (Symmetrix Remote Data Facility) Mirror of Symmetrix logical Volume maintained in a separate Symmetrix 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 37 Data protection options are configured at the volume level and the same Symmetrix can employ a variety of protection schemes. Dynamic Sparing: Disks in the back-end of the Array which are reserved for use when a physical disk fails. When a physical disk fails the dynamic spare will be used as a replacement. SRDF is a remote replication solution and will be discussed later on in the Business Continuity section of this course. Disk Storage Systems - 37

38 Assigning Symmetrix Logical Volumes to Hosts Configure Symmetrix Logical Volumes Map Symmetrix Logical Volumes to Front-end ports Performed via EMC ControlCenter or Solutions Enabler Make Symmetrix Logical Volumes accessible to hosts SAN Environment Zone Hosts to Front-end ports Perform LUN Masking Can be performed via EMC ControlCenter or Solutions Enabler LUN Masking information is maintained on the Symmetrix in the VCM Database (VCMDB) LUN Masking information is also flashed to all the front-end directors 2006 EMC Corporation. All rights reserved. Disk Storage Systems - 38 Assigning Symmetrix Logical Volumes to hosts is a 3 step process: 1. Configure SLVs (discussed in the last few slides) 2. Map the SLVs to front-end ports When a SLV is created it is not assigned to any front-end port, thus one must assign SLVs to front-end ports before a host can access the same. Mapping is the task of assigning SLVs to front-end ports. For redundancy one would map a device to more that one front-end port. 3. Make SLVs accessible to hosts SAN Environment Zoning and LUN masking has to be performed. We will discuss Zoning and LUN Masking in the SAN lecture later on in this course. Disk Storage Systems - 38

PESIT Bangalore South Campus

PESIT Bangalore South Campus PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -100 Department of Information Science & Engineering SOLUTION MANUAL INTERNAL ASSESSMENT TEST 1 Subject & Code : Storage Area

More information

EMC Symmetrix DMX Series The High End Platform. Tom Gorodecki EMC

EMC Symmetrix DMX Series The High End Platform. Tom Gorodecki EMC 1 EMC Symmetrix Series The High End Platform Tom Gorodecki EMC 2 EMC Symmetrix -3 Series World s Most Trusted Storage Platform Symmetrix -3: World s Largest High-end Storage Array -3 950: New High-end

More information

Technical Note P/N REV A01 March 29, 2007

Technical Note P/N REV A01 March 29, 2007 EMC Symmetrix DMX-3 Best Practices Technical Note P/N 300-004-800 REV A01 March 29, 2007 This technical note contains information on these topics: Executive summary... 2 Introduction... 2 Tiered storage...

More information

Introduction to the CX700

Introduction to the CX700 Engineering White Paper Introduction to the CX700 Abstract This white paper introduces the full 2 Gb architecture and functionality of the CX700 storage system. It compares the features and capabilities

More information

Connectivity. Module 2.2. Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved. Connectivity - 1

Connectivity. Module 2.2. Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved. Connectivity - 1 Connectivity Module 2.2 2006 EMC Corporation. All rights reserved. Connectivity - 1 Connectivity Upon completion of this module, you will be able to: Describe the physical components of a networked storage

More information

Storage Update and Storage Best Practices for Microsoft Server Applications. Dennis Martin President, Demartek January 2009 Copyright 2009 Demartek

Storage Update and Storage Best Practices for Microsoft Server Applications. Dennis Martin President, Demartek January 2009 Copyright 2009 Demartek Storage Update and Storage Best Practices for Microsoft Server Applications Dennis Martin President, Demartek January 2009 Copyright 2009 Demartek Agenda Introduction Storage Technologies Storage Devices

More information

EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005

EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005 EMC CLARiiON Database Storage Solutions: Microsoft SQL Server 2000 and 2005 Best Practices Planning Abstract This technical white paper explains best practices associated with Microsoft SQL Server 2000

More information

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary v1.0 January 8, 2010 Introduction This guide describes the highlights of a data warehouse reference architecture

More information

EMC CLARiiON Backup Storage Solutions

EMC CLARiiON Backup Storage Solutions Engineering White Paper Backup-to-Disk Guide with Computer Associates BrightStor ARCserve Backup Abstract This white paper describes how to configure EMC CLARiiON CX series storage systems with Computer

More information

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. 1 This training module is divided in six main chapters.

More information

DELL EMC UNITY: HIGH AVAILABILITY

DELL EMC UNITY: HIGH AVAILABILITY DELL EMC UNITY: HIGH AVAILABILITY A Detailed Review ABSTRACT This white paper discusses the high availability features on Dell EMC Unity purposebuilt solution. October, 2017 1 WHITE PAPER The information

More information

VERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path

VERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path White Paper VERITAS Storage Foundation for Windows VERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path 12/6/2004 1 Introduction...3 Dynamic MultiPathing (DMP)...3

More information

Information Storage and Management

Information Storage and Management Information Storage and Management Storing, Managing, and Protecting Digital Information Edited by G. Somasundaram Alok Shrivastava EMC Education Services W WILEY Wiley Publishing, Inc. Contents Foreword

More information

3.1. Storage. Direct Attached Storage (DAS)

3.1. Storage. Direct Attached Storage (DAS) 3.1. Storage Data storage and access is a primary function of a network and selection of the right storage strategy is critical. The following table describes the options for server and network storage.

More information

Drive Sparing in EMC Symmetrix DMX-3 and DMX-4 Systems

Drive Sparing in EMC Symmetrix DMX-3 and DMX-4 Systems Applied Technology Abstract Drive sparing significantly increases data protection and availability. EMC Symmetrix systems support dynamic and permanent sparing. This white paper explains the benefits of

More information

Computer Organization and Structure. Bing-Yu Chen National Taiwan University

Computer Organization and Structure. Bing-Yu Chen National Taiwan University Computer Organization and Structure Bing-Yu Chen National Taiwan University Storage and Other I/O Topics I/O Performance Measures Types and Characteristics of I/O Devices Buses Interfacing I/O Devices

More information

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM EMC SYMMETRIX VMAX 40K STORAGE SYSTEM The EMC Symmetrix VMAX 40K storage system delivers unmatched scalability and high availability for the enterprise while providing market-leading functionality to accelerate

More information

Rrootshell Technologiiss Pvt Ltd.

Rrootshell Technologiiss Pvt Ltd. Course Description Information Storage and Management (ISM) training programme provides a comprehensive introduction to information storage technology that will enable you to make more informed decisions

More information

Storage Area Networks SAN. Shane Healy

Storage Area Networks SAN. Shane Healy Storage Area Networks SAN Shane Healy Objective/Agenda Provide a basic overview of what Storage Area Networks (SAN) are, what the constituent components are, and how these components fit together to deliver

More information

EMC Tiered Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON CX4 and Enterprise Flash Drives

EMC Tiered Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON CX4 and Enterprise Flash Drives EMC Tiered Storage for Microsoft SQL Server 2008 Enabled by EMC CLARiiON CX4 and Enterprise Flash Drives A Detailed Review EMC Information Infrastructure Solutions Abstract This white paper demonstrates

More information

Definition of RAID Levels

Definition of RAID Levels RAID The basic idea of RAID (Redundant Array of Independent Disks) is to combine multiple inexpensive disk drives into an array of disk drives to obtain performance, capacity and reliability that exceeds

More information

Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems

Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems Applied Technology Abstract This white paper is an overview of Power Vault operation in EMC Symmetrix DMX-3 and Symmetrix DMX-4 environments.

More information

CS3600 SYSTEMS AND NETWORKS

CS3600 SYSTEMS AND NETWORKS CS3600 SYSTEMS AND NETWORKS NORTHEASTERN UNIVERSITY Lecture 9: Mass Storage Structure Prof. Alan Mislove (amislove@ccs.neu.edu) Moving-head Disk Mechanism 2 Overview of Mass Storage Structure Magnetic

More information

S SNIA Storage Networking Management & Administration

S SNIA Storage Networking Management & Administration S10 201 SNIA Storage Networking Management & Administration Version 23.3 Topic 1, Volume A QUESTION NO: 1 Which two (2) are advantages of ISL over subscription? (Choose two.) A. efficient ISL bandwidth

More information

I/O CANNOT BE IGNORED

I/O CANNOT BE IGNORED LECTURE 13 I/O I/O CANNOT BE IGNORED Assume a program requires 100 seconds, 90 seconds for main memory, 10 seconds for I/O. Assume main memory access improves by ~10% per year and I/O remains the same.

More information

I/O CANNOT BE IGNORED

I/O CANNOT BE IGNORED LECTURE 13 I/O I/O CANNOT BE IGNORED Assume a program requires 100 seconds, 90 seconds for main memory, 10 seconds for I/O. Assume main memory access improves by ~10% per year and I/O remains the same.

More information

Chapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition

Chapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition Chapter 10: Mass-Storage Systems Silberschatz, Galvin and Gagne 2013 Chapter 10: Mass-Storage Systems Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space

More information

EMC SYMMETRIX VMAX 40K SYSTEM

EMC SYMMETRIX VMAX 40K SYSTEM EMC SYMMETRIX VMAX 40K SYSTEM The EMC Symmetrix VMAX 40K storage system delivers unmatched scalability and high availability for the enterprise while providing market-leading functionality to accelerate

More information

Virtual Memory. Reading. Sections 5.4, 5.5, 5.6, 5.8, 5.10 (2) Lecture notes from MKP and S. Yalamanchili

Virtual Memory. Reading. Sections 5.4, 5.5, 5.6, 5.8, 5.10 (2) Lecture notes from MKP and S. Yalamanchili Virtual Memory Lecture notes from MKP and S. Yalamanchili Sections 5.4, 5.5, 5.6, 5.8, 5.10 Reading (2) 1 The Memory Hierarchy ALU registers Cache Memory Memory Memory Managed by the compiler Memory Managed

More information

Storage. Hwansoo Han

Storage. Hwansoo Han Storage Hwansoo Han I/O Devices I/O devices can be characterized by Behavior: input, out, storage Partner: human or machine Data rate: bytes/sec, transfers/sec I/O bus connections 2 I/O System Characteristics

More information

EMC CLARiiON CX3 Series FCP

EMC CLARiiON CX3 Series FCP EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2008

More information

1. Introduction. Traditionally, a high bandwidth file system comprises a supercomputer with disks connected

1. Introduction. Traditionally, a high bandwidth file system comprises a supercomputer with disks connected 1. Introduction Traditionally, a high bandwidth file system comprises a supercomputer with disks connected by a high speed backplane bus such as SCSI [3][4] or Fibre Channel [2][67][71]. These systems

More information

Technologies of ETERNUS6000 and ETERNUS3000 Mission-Critical Disk Arrays

Technologies of ETERNUS6000 and ETERNUS3000 Mission-Critical Disk Arrays Technologies of ETERNUS6000 and ETERNUS3000 Mission-Critical Disk Arrays V Yoshinori Terao (Manuscript received December 12, 2005) Fujitsu has developed the ETERNUS6000 and ETERNUS3000 disk arrays for

More information

Snia S Storage Networking Management/Administration.

Snia S Storage Networking Management/Administration. Snia S10-200 Storage Networking Management/Administration http://killexams.com/exam-detail/s10-200 QUESTION: 85 What are two advantages of over-subscription? (Choose two.) A. saves on ISL links B. decreases

More information

EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S

EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S Enterprise Solutions for Microsoft SQL Server 2005 EMC CLARiiON CX3-80 EMC Metropolitan Recovery for SQL Server 2005 Enabled by Replication Manager and MirrorView/S Reference Architecture EMC Global Solutions

More information

Storage Systems. Storage Systems

Storage Systems. Storage Systems Storage Systems Storage Systems We already know about four levels of storage: Registers Cache Memory Disk But we've been a little vague on how these devices are interconnected In this unit, we study Input/output

More information

The term "physical drive" refers to a single hard disk module. Figure 1. Physical Drive

The term physical drive refers to a single hard disk module. Figure 1. Physical Drive HP NetRAID Tutorial RAID Overview HP NetRAID Series adapters let you link multiple hard disk drives together and write data across them as if they were one large drive. With the HP NetRAID Series adapter,

More information

Chapter 10: Mass-Storage Systems

Chapter 10: Mass-Storage Systems Chapter 10: Mass-Storage Systems Silberschatz, Galvin and Gagne 2013 Chapter 10: Mass-Storage Systems Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space

More information

A SCSI Transport Layer Extension with Separate Data and Control Paths for Scalable Storage-Area-Network Architectures

A SCSI Transport Layer Extension with Separate Data and Control Paths for Scalable Storage-Area-Network Architectures Technion - Israel Institute of technology Department of Electrical Engineering SCSI-DSDC A SCSI Transport Layer Extension with Separate Data and Control Paths for Scalable Storage-Area-Network Architectures

More information

CONFIGURING ftscalable STORAGE ARRAYS ON OpenVOS SYSTEMS

CONFIGURING ftscalable STORAGE ARRAYS ON OpenVOS SYSTEMS Best Practices CONFIGURING ftscalable STORAGE ARRAYS ON OpenVOS SYSTEMS Best Practices 2 Abstract ftscalable TM Storage G1, G2 and G3 arrays are highly flexible, scalable hardware storage subsystems that

More information

SYSTEM UPGRADE, INC Making Good Computers Better. System Upgrade Teaches RAID

SYSTEM UPGRADE, INC Making Good Computers Better. System Upgrade Teaches RAID System Upgrade Teaches RAID In the growing computer industry we often find it difficult to keep track of the everyday changes in technology. At System Upgrade, Inc it is our goal and mission to provide

More information

Today: Secondary Storage! Typical Disk Parameters!

Today: Secondary Storage! Typical Disk Parameters! Today: Secondary Storage! To read or write a disk block: Seek: (latency) position head over a track/cylinder. The seek time depends on how fast the hardware moves the arm. Rotational delay: (latency) time

More information

CONTENTS. 1. Introduction. 2. How To Store Data. 3. How To Access Data. 4. Manage Data Storage. 5. Benefits Of SAN. 6. Conclusion

CONTENTS. 1. Introduction. 2. How To Store Data. 3. How To Access Data. 4. Manage Data Storage. 5. Benefits Of SAN. 6. Conclusion CONTENTS 1. Introduction 2. How To Store Data 3. How To Access Data 4. Manage Data Storage 5. Benefits Of SAN 6. Conclusion 1. Introduction: A Storage Area Network (SAN) is a dedicated network that carries

More information

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo Exam : S10-200 Title : Snia Storage Network Management/Administration Version : Demo 1. A SAN architect is asked to implement an infrastructure for a production and a test environment using Fibre Channel

More information

POWERMAX FAMILY. Appliance-based packaging. PowerMax 2000 and Specifications. Specification Sheet. PowerMax Arrays

POWERMAX FAMILY. Appliance-based packaging. PowerMax 2000 and Specifications. Specification Sheet. PowerMax Arrays Specification Sheet POWERMAX FAMILY PowerMax Arrays PowerMax 2000 and 8000 The new family of Dell EMC NVMe (Non-Volatile Memory Express) arrays resets the bar for enterprise storage with new levels of

More information

Welcome to PowerPath Foundations

Welcome to PowerPath Foundations IMPACT Home IMPACT modules consist of focused, in-depth training content that can be consumed in about 1-2 hours Welcome to PowerPath Foundations Course Description Start Training Run/Download the PowerPoint

More information

A Look at CLARiiON with ATA CX Series Disk Drives and Enclosures

A Look at CLARiiON with ATA CX Series Disk Drives and Enclosures A Look at CLARiiON with ATA CX Series Disk Drives and Enclosures Applied Technology Abstract As the need for data storage continues to grow, developing lower-cost storage devices becomes imperative. This

More information

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018 EonStor GS Family Best Practices Guide White Paper Version: 1.1 Updated: Apr., 2018 Abstract: This guide provides recommendations of best practices for installation and configuration to meet customer performance

More information

SATA RAID For The Enterprise? Presented at the THIC Meeting at the Sony Auditorium, 3300 Zanker Rd, San Jose CA April 19-20,2005

SATA RAID For The Enterprise? Presented at the THIC Meeting at the Sony Auditorium, 3300 Zanker Rd, San Jose CA April 19-20,2005 Logo of Your organization SATA RAID For The Enterprise? Scott K. Cleland, Director of Marketing AMCC 455 West Maude Ave., Sunnyvale, CA 94085-3517 Phone:+1-408-523-1079 FAX: +1-408-523-1001 E-mail: scleland@amcc.com

More information

EMC SAN Copy Command Line Interfaces

EMC SAN Copy Command Line Interfaces EMC SAN Copy Command Line Interfaces REFERENCE P/N 069001189 REV A13 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2008 EMC Corporation. All

More information

Computer Architecture 计算机体系结构. Lecture 6. Data Storage and I/O 第六讲 数据存储和输入输出. Chao Li, PhD. 李超博士

Computer Architecture 计算机体系结构. Lecture 6. Data Storage and I/O 第六讲 数据存储和输入输出. Chao Li, PhD. 李超博士 Computer Architecture 计算机体系结构 Lecture 6. Data Storage and I/O 第六讲 数据存储和输入输出 Chao Li, PhD. 李超博士 SJTU-SE346, Spring 2018 Review Memory hierarchy Cache and virtual memory Locality principle Miss cache, victim

More information

EMC CLARiiON CX3 UltraScale Series The Proven Midrange Storage

EMC CLARiiON CX3 UltraScale Series The Proven Midrange Storage EMC CLARiiON CX3 UltraScale Series The Proven Midrange Storage Erez Etzyon Senior Technology Consultant CLARiiON CX3 UltraScale Series Breakthrough Architecture and Innovation Designed to Deliver New Levels

More information

EMC Solutions for Enterprises. EMC Tiered Storage for Oracle. ILM Enabled by EMC Symmetrix V-Max. Reference Architecture. EMC Global Solutions

EMC Solutions for Enterprises. EMC Tiered Storage for Oracle. ILM Enabled by EMC Symmetrix V-Max. Reference Architecture. EMC Global Solutions EMC Solutions for Enterprises EMC Tiered Storage for Oracle ILM Enabled by EMC Symmetrix V-Max Reference Architecture EMC Global Solutions Copyright and Trademark Information Copyright 2009 EMC Corporation.

More information

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange 2007 Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange Server Enabled by MirrorView/S and Replication Manager Reference Architecture EMC

More information

VERITAS Dynamic Multipathing. Increasing the Availability and Performance of the Data Path

VERITAS Dynamic Multipathing. Increasing the Availability and Performance of the Data Path VERITAS Dynamic Multipathing Increasing the Availability and Performance of the Data Path 1 TABLE OF CONTENTS I/O Path Availability and Performance... 3 Dynamic Multipathing... 3 VERITAS Storage Foundation

More information

A GPFS Primer October 2005

A GPFS Primer October 2005 A Primer October 2005 Overview This paper describes (General Parallel File System) Version 2, Release 3 for AIX 5L and Linux. It provides an overview of key concepts which should be understood by those

More information

Performance of relational database management

Performance of relational database management Building a 3-D DRAM Architecture for Optimum Cost/Performance By Gene Bowles and Duke Lambert As systems increase in performance and power, magnetic disk storage speeds have lagged behind. But using solidstate

More information

Introduction to NetApp E-Series E2700 with SANtricity 11.10

Introduction to NetApp E-Series E2700 with SANtricity 11.10 d Technical Report Introduction to NetApp E-Series E2700 with SANtricity 11.10 Todd Edwards, NetApp March 2014 TR-4275 1 Introduction to NetApp E-Series E2700 with SANtricity 11.10 TABLE OF CONTENTS 1

More information

Performance/Throughput

Performance/Throughput Markets, S. Zaffos Research Note 31 March 2003 ATA Disks Redefine RAID Price/Performance Cost-optimized storage infrastructures should include redundant arrays of independent disks built with low-cost

More information

SGI InfiniteStorage 350 Quick Start Guide

SGI InfiniteStorage 350 Quick Start Guide SGI InfiniteStorage 350 Quick Start Guide 007-4932-001 CONTRIBUTORS Written by Mark Schwenden Illustrated by Chrystie Danzer Production by Mark Schwenden Additional contributions by Dick Brownell, Cheryl

More information

COMP283-Lecture 3 Applied Database Management

COMP283-Lecture 3 Applied Database Management COMP283-Lecture 3 Applied Database Management Introduction DB Design Continued Disk Sizing Disk Types & Controllers DB Capacity 1 COMP283-Lecture 3 DB Storage: Linear Growth Disk space requirements increases

More information

Chapter 12: Mass-Storage

Chapter 12: Mass-Storage Chapter 12: Mass-Storage Systems Chapter 12: Mass-Storage Systems Revised 2010. Tao Yang Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space Management

More information

Mladen Stefanov F48235 R.A.I.D

Mladen Stefanov F48235 R.A.I.D R.A.I.D Data is the most valuable asset of any business today. Lost data, in most cases, means lost business. Even if you backup regularly, you need a fail-safe way to ensure that your data is protected

More information

Best Practices for deploying VMware ESX 3.x and 2.5.x server with EMC Storage products. Sheetal Kochavara Systems Engineer, EMC Corporation

Best Practices for deploying VMware ESX 3.x and 2.5.x server with EMC Storage products. Sheetal Kochavara Systems Engineer, EMC Corporation Best Practices for deploying VMware ESX 3.x and 2.5.x server with EMC Storage products Sheetal Kochavara Systems Engineer, EMC Corporation Agenda Overview of EMC Hardware and Software Best practices with

More information

White Paper. A System for Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft

White Paper. A System for  Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft White Paper Mimosa Systems, Inc. November 2007 A System for Email Archiving, Recovery, and Storage Optimization Mimosa NearPoint for Microsoft Exchange Server and EqualLogic PS Series Storage Arrays CONTENTS

More information

Chapter 11: File System Implementation. Objectives

Chapter 11: File System Implementation. Objectives Chapter 11: File System Implementation Objectives To describe the details of implementing local file systems and directory structures To describe the implementation of remote file systems To discuss block

More information

Exchange 2003 Archiving for Operational Efficiency

Exchange 2003 Archiving for Operational Efficiency Exchange 2003 Archiving for Operational Efficiency Enabled by EmailXtender Reference Architecture EMC Global Solutions Operations EMC Corporation Corporate Headquarters Hopkinton MA 01748-9103 1.508.435.1000

More information

Reference Architecture

Reference Architecture EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 in VMware ESX Server EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com

More information

Chapter 12: Mass-Storage Systems. Operating System Concepts 8 th Edition,

Chapter 12: Mass-Storage Systems. Operating System Concepts 8 th Edition, Chapter 12: Mass-Storage Systems, Silberschatz, Galvin and Gagne 2009 Chapter 12: Mass-Storage Systems Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management

More information

Vendor: EMC. Exam Code: E Exam Name: CLARiiON Installation and Troubleshooting Specialist. Version: Demo

Vendor: EMC. Exam Code: E Exam Name: CLARiiON Installation and Troubleshooting Specialist. Version: Demo Vendor: EMC Exam Code: E20-611 Exam Name: CLARiiON Installation and Troubleshooting Specialist Version: Demo Question No : 1 On a CLARiiON CX4-480 array what is the maximum number of drives supported on

More information

CMSC 424 Database design Lecture 12 Storage. Mihai Pop

CMSC 424 Database design Lecture 12 Storage. Mihai Pop CMSC 424 Database design Lecture 12 Storage Mihai Pop Administrative Office hours tomorrow @ 10 Midterms are in solutions for part C will be posted later this week Project partners I have an odd number

More information

EMC FAST CACHE. A Detailed Review. White Paper

EMC FAST CACHE. A Detailed Review. White Paper White Paper EMC FAST CACHE A Detailed Review Abstract This white paper describes EMC FAST Cache technology in CLARiiON, Celerra unified, and VNX storage systems. It describes the implementation of the

More information

OS and Hardware Tuning

OS and Hardware Tuning OS and Hardware Tuning Tuning Considerations OS Threads Thread Switching Priorities Virtual Memory DB buffer size File System Disk layout and access Hardware Storage subsystem Configuring the disk array

More information

V. Mass Storage Systems

V. Mass Storage Systems TDIU25: Operating Systems V. Mass Storage Systems SGG9: chapter 12 o Mass storage: Hard disks, structure, scheduling, RAID Copyright Notice: The lecture notes are mainly based on modifications of the slides

More information

EMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005

EMC CLARiiON CX3-80. Enterprise Solutions for Microsoft SQL Server 2005 Enterprise Solutions for Microsoft SQL Server 2005 EMC CLARiiON CX3-80 EMC Long Distance Recovery for SQL Server 2005 Enabled by Replication Manager and RecoverPoint CRR Reference Architecture EMC Global

More information

1 of 6 4/8/2011 4:08 PM Electronic Hardware Information, Guides and Tools search newsletter subscribe Home Utilities Downloads Links Info Ads by Google Raid Hard Drives Raid Raid Data Recovery SSD in Raid

More information

The Oracle Database Appliance I/O and Performance Architecture

The Oracle Database Appliance I/O and Performance Architecture Simple Reliable Affordable The Oracle Database Appliance I/O and Performance Architecture Tammy Bednar, Sr. Principal Product Manager, ODA 1 Copyright 2012, Oracle and/or its affiliates. All rights reserved.

More information

OS and HW Tuning Considerations!

OS and HW Tuning Considerations! Administração e Optimização de Bases de Dados 2012/2013 Hardware and OS Tuning Bruno Martins DEI@Técnico e DMIR@INESC-ID OS and HW Tuning Considerations OS " Threads Thread Switching Priorities " Virtual

More information

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment DATASHEET TM NST6000 UNIFIED HYBRID STORAGE Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment UNIFIED The Nexsan NST6000 unified hybrid storage system is ideal for organizations

More information

EMC SYMMETRIX VMAX 10K

EMC SYMMETRIX VMAX 10K EMC SYMMETRIX VMAX 10K EMC Symmetrix VMAX 10K with the Enginuity operating environment delivers a multi-controller, scale-out architecture with consolidation and efficiency for the enterprise. The VMAX

More information

IBM System Storage DS4800

IBM System Storage DS4800 Scalable, high-performance storage for on demand computing environments IBM System Storage DS4800 Highlights 4 Gbps Fibre Channel interface Includes IBM System Storage technology DS4000 Storage Manager

More information

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results Dell Fluid Data solutions Powerful self-optimized enterprise storage Dell Compellent Storage Center: Designed for business results The Dell difference: Efficiency designed to drive down your total cost

More information

EMC DMX Disk Arrays with IBM DB2 Universal Database Applied Technology

EMC DMX Disk Arrays with IBM DB2 Universal Database Applied Technology EMC DMX Disk Arrays with IBM DB2 Universal Database Applied Technology Abstract This paper examines the attributes of the IBM DB2 UDB V8.2 database as they relate to optimizing the configuration for the

More information

IBM System Storage DS5020 Express

IBM System Storage DS5020 Express IBM DS5020 Express Manage growth, complexity, and risk with scalable, high-performance storage Highlights Mixed host interfaces support (FC/iSCSI) enables SAN tiering Balanced performance well-suited for

More information

Tech Sheet Benefits of Dual Redundant Active/Active Storage Architecture

Tech Sheet Benefits of Dual Redundant Active/Active Storage Architecture Tech Sheet Benefits of Dual Redundant Active/Active Storage Architecture Tech Sheet Introduction Storage servers constitute the very foundation of any data center and their features, performance and scalability

More information

Data center requirements

Data center requirements Prerequisites, page 1 Data center workflow, page 2 Determine data center requirements, page 2 Gather data for initial data center planning, page 2 Determine the data center deployment model, page 3 Determine

More information

Deploying EMC CLARiiON CX4-240 FC with VMware View. Introduction... 1 Hardware and Software Requirements... 2

Deploying EMC CLARiiON CX4-240 FC with VMware View. Introduction... 1 Hardware and Software Requirements... 2 Deploying EMC CLARiiON CX4-240 FC with View Contents Introduction... 1 Hardware and Software Requirements... 2 Hardware Resources... 2 Software Resources...2 Solution Configuration... 3 Network Architecture...

More information

RAID SEMINAR REPORT /09/2004 Asha.P.M NO: 612 S7 ECE

RAID SEMINAR REPORT /09/2004 Asha.P.M NO: 612 S7 ECE RAID SEMINAR REPORT 2004 Submitted on: Submitted by: 24/09/2004 Asha.P.M NO: 612 S7 ECE CONTENTS 1. Introduction 1 2. The array and RAID controller concept 2 2.1. Mirroring 3 2.2. Parity 5 2.3. Error correcting

More information

Database Systems II. Secondary Storage

Database Systems II. Secondary Storage Database Systems II Secondary Storage CMPT 454, Simon Fraser University, Fall 2009, Martin Ester 29 The Memory Hierarchy Swapping, Main-memory DBMS s Tertiary Storage: Tape, Network Backup 3,200 MB/s (DDR-SDRAM

More information

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Backup and Recovery for Microsoft Exchange 2007 EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1 Copyright 2011, 2012 EMC Corporation. All rights reserved. Published March, 2012 EMC believes the information in this publication

More information

CS370 Operating Systems

CS370 Operating Systems CS370 Operating Systems Colorado State University Yashwant K Malaiya Fall 2016 Lecture 35 Mass Storage Slides based on Text by Silberschatz, Galvin, Gagne Various sources 1 1 Questions For You Local/Global

More information

IBM Europe Announcement ZG , dated February 13, 2007

IBM Europe Announcement ZG , dated February 13, 2007 IBM Europe Announcement ZG07-0221, dated February 13, 2007 Cisco MDS 9200 for IBM System Storage switches, models 9216i and 9216A, offer enhanced performance, scalability, multiprotocol capabilities, and

More information

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15 EMC SAN Copy Command Line Interface (CLI) Reference P/N 069001189 REV A15 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2010 EMC Corporation.

More information

Administrivia. CMSC 411 Computer Systems Architecture Lecture 19 Storage Systems, cont. Disks (cont.) Disks - review

Administrivia. CMSC 411 Computer Systems Architecture Lecture 19 Storage Systems, cont. Disks (cont.) Disks - review Administrivia CMSC 411 Computer Systems Architecture Lecture 19 Storage Systems, cont. Homework #4 due Thursday answers posted soon after Exam #2 on Thursday, April 24 on memory hierarchy (Unit 4) and

More information

Assessing performance in HP LeftHand SANs

Assessing performance in HP LeftHand SANs Assessing performance in HP LeftHand SANs HP LeftHand Starter, Virtualization, and Multi-Site SANs deliver reliable, scalable, and predictable performance White paper Introduction... 2 The advantages of

More information

Vendor must indicate at what level its proposed solution will meet the College s requirements as delineated in the referenced sections of the RFP:

Vendor must indicate at what level its proposed solution will meet the College s requirements as delineated in the referenced sections of the RFP: Vendor must indicate at what level its proposed solution will the College s requirements as delineated in the referenced sections of the RFP: 2.3 Solution Vision Requirement 2.3 Solution Vision CCAC will

More information

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange in a VMware Environment Enabled by MirrorView/S Reference Architecture EMC Global

More information

ETERNUS DX60 and DX80

ETERNUS DX60 and DX80 Highlights Low environmental impact Highly scalable & versatile connectivity User friendly management systems Outstanding reliability 1 Overview (1) are designed to meet the needs of all environments from

More information

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID Overview The Smart Array 6i controller is an Ultra320 intelligent array controller for entry-level, hardware-based fault tolerance for protection of OS, applications, and logs. Most models have one internal-only

More information