1 CLAMP-ON Graphic Power Quality Analyzer Software Users Manual v3.4
2 Table of Contents 1. Introduction Operating Environment Hardware Connecting Procedures Software Installation Install Application Program Install USB Driver Software Operation Start Executing Program Functions of Main Screen Setting Parameters Communication Down Load Data Clear Memory Communication Communication Screen I Communication Screen II Communication Screen III Communication Screen IV Open / Save Data Setting MD Time & Sample Rate Choosing Printer Waveform Waveform Redrawing I
3 Table of Contents 4.10 Printing Waveform Operation Modes Mode Resetting II
4 Introduction 1. Introduction 1.1 Operating Environment * Application program should be installed in the operation system of Microsoft Windows Vista / XP / 2000 (SP3). * NI-VISA Runtime Engine should be installed (Application program will install it automatically). * USB driver program should be installed (refer to chapter 2.2). 1.2 Hardware * Personal Computer (PC): we recommend the processor of Pentium III Celeron 600MHz or above. * RAM: min. 256MB, but we recommend 512MB of RAM or more. * Screen resolution: requires 1,024 x 768 pixels. * CLAMP-ON Graphic Power Quality Analyzer. * USB cable. 1.3 Connecting Procedures Step 1: Turn on PC and CLAMP-ON Graphic Power Quality Analyzer. Step 2: Connect RS-232 to USB Cable. Step 3: Start Application Program of CLAMP-ON Graphic Power Quality Analyzer. Step 4: Select correct Serial Port Number. 1-1
5 Software Installation 2. Software Installation 2.1 Install Application Program Execute setup.exe (which is in installation disc) to enter the procedures of installing Application Program. Please follow the instructions to install Application Program. 1. After putting the installation disc into CD-ROM drive, the application program will automatically execute the installation. 2. If the installation is not automatically executed, please choose the setup.exe program in the installation disc to perform the installation. 3. After Application Program has been installed, please Restart the PC. 2-1
6 Software Installation 2.2 Install USB Driver Choose USB Driver Directory in the installation disc, click CP210x_VCP_Win2K_XP_S2K3.exe program (for Windows Vista / XP / 2000) to execute the installation of USB Driver. 1. If the driver can t detect the hardware, please remove the hardware and then plug it in properly. 2-2
7 Software Operation 3. Software Operation 3.1 Start Executing Program In Start -> All Programs, choose CLAMP-ON Graphic Power Quality Analyzer to start executing program. Choose the Serial Port connected to CLAMP-ON Graphic Power Quality Analyzer. 1. Click to choose the serial port number connected to CLAMP-ON Graphic Power Quality Analyzer. 2. After choosing correct serial port number, click to confirm. 3-1
8 Software Operation 3.2 Functions of Main Screen Get in the main screen of software operation Tool bar including functions like: Setting parameters, Communication, Download/Clear datalogger, Information of software version, and Exit. 2. System messages including: initial status, present status, down-load percentage, etc. 3-2
9 Software Operation 3.3 Setting Parameters click File -> Setup of tool bar to get in parameter-setting screen. Parameters including date/time, datalogger, system, etc. After being set in Application Program, the parameters are written in the memory of CLAMP-ON Graphic Power Quality Analyzer Click to set date and time. 2. Click to finish setting. 3-3
10 Software Operation Datalogger-setting including: Sample, Start time and Stop time of sampling, Waveform point of sampling. System-setting including: Voltage Transformer (VT), Transient Reference Voltage (TRANS REF) and its range (%), Frequency (Hz), Max. Demanding Time (MD Time) and Auto power off. 3-4
11 Software Operation 3.4 Communication Click <Communication> of tool bar to get in Communication screen. To perform this Communication function, the range of CLAMP-ON Graphic Power Quality Analyzer should be adjusted to 3 Phase, 1 Phase, V, A, or VA Too bar including: File open (Open), File save (Save), File close (Close), Max. demanding time and Sampling rate (MD Time & Sample Rate), Screen printing (Print), Curve graphing (Waveform), Choosing operation mode (View), Exit. 3-5
12 Software Operation 2. Communication messages including: Present time (Current Time), Start time of sampling (Start Time), Max. Demanding Time and Present sampling rate (MD Time, Sample Rate), Voltage Transformer (VT), Frequency (Frequency), number of sample already recorded (Sample Count), sample showed at present (Present Sample). 3.5 Down Load Data Click Datalogger -> Down Load Data (Ctrl+D) of Tool bar to get in Down Load Data. The system message shows the current down load %. To stop downloading, press Reset on the right of screen. 3-6
13 Software Operation 3.6 Clear Memory Click Datalogger -> Clear Memory (Ctrl+C) of tool bar to get in Clear Memory screen. Click Clear Memory in the dialogue to clear the memory of CLAMP-ON Graphic Power Quality Analyzer. Once the memory of CLAMP-ON Graphic Power Quality Analyzer has been cleared, it can t be recovered anymore. If it s necessary to save the memory, first down load it and then save it in PC (refer to chapter 4.5). 3-7
14 Communication 4. Communication The software will display what is shown in the LCD of analyzer. Users should press the FUNC button to select display. 4.1 Communication Screen I Adjust the sliding switch of CLAMP-ON Graphic Power Quality Analyzer to 3 Phase (or 1Phase), and Click Communication to get in Communication screen Display of Apparent Power (S) and KVAH, True Power (P) and KWH, Reactive Power (Q) and KVARH. 2. Display of Average demanding (Ave.), Max. Demanding (Max.). 3. Display of Power factor (PF), PFH, Phase angle, Horse power (HP). 4-1
15 Communication 4.2 Communication Screen II Adjust the sliding switch of CLAMP-ON Graphic Power Quality Analyzer to V and get in Communication screen. After measuring voltage/harmonics, you will get in below screen. (refer to below remarks for the function of current/harmonics measurement) Display of voltage and waveform. 2. Display of amplitude spectrum. 3. Display of harmonics (selective function). 4. Display of present RMS, Peak, THD. 5. Display of magnitude, percentage. 4-2
16 Communication 4.3 Communication Screen III Adjust the sliding switch of CLAMP-ON Graphic Power Quality Analyzer to VA and get in Communication screen. After measuring voltage/current/waveform, you will get in below screen Display of voltage, current and waveform. 2. Display of present P, S and Phase readings. 4-3
17 Communication 4.4 Communication Screen IV Adjust the sliding switch of CLAMP-ON Graphic Power Quality Analyzer to VA and get in Communication screen. After measuring voltage/waveform, you will get in below screen. (refer to below remarks for the function of current/waveform measurement) Display of voltage and waveform. 2. Display of present RMS and Peak readings. 4-4
18 Communication 4.5 Open / Save Data You can Open/Save the data of Communication screen or the down-load data from/to PC. Click File -> Save (Ctrl+S) in Communication screen, the data of the present screen can be saved as.csv files. 1 The down load information of transient data includes: Transient starting time (Start Time), Duration of transience (Duration), End time of transience (End Time), Higher than set voltage (High), Lower than set voltage (Low) and Opening circuit (Open). 4.6 Setting MD Time & Sample Rate 4-5
19 Communication Click File -> MD Time & Sample Rate in Communication screen and then click Setting in the dialogue. The max. demanding time (MD Time) and sampling rate (Sample Rate) can be reset. When you finish setting parameters and press Enter, the recorded data will be cleared (Reset). If you want to save this data, you must save it before resetting MD Time & Sample Rate. 4-6
20 Communication 4.7 Choosing Printer Click File -> Print in Communication screen, and then click beside the Name column to choose the printer you d like to use. There is also a printer-selection function in Waveform function. 4.8 Waveform Click Waveform in Communication screen, then choose the waveform name that you want. In various Communication screens, you can choose among the following waveform names: Communication screen I : V, A, S, P, Q, PF, Phase, KVAH, KWH, KVARH, PFH, VA(AD), W(AD), VA(MD), W(MD) Communication screen II : RMS, Peak, THD Communication screen III : V, A, P, S, Phase Communication screen IV : RMS, Peak 4-7
21 Communication 4.9 Waveform Redrawing In Waveform screen, you can adjust Scale and Cursor position manually to observe readings. If you improperly adjust Scale or Cursor position, click File -> Redraw to perform Waveform redrawing which can automatically make a proper adjustment Display readings of present cursor position. 2. Draw chosen waveform. 3. Adjust present cursor position (or drag the cursor). 4. Click Scale input values to change observation range Printing Waveform 4-8
22 Communication Click File -> Print to perform waveform printing function which can output the present observed screen to a printer. (There is also a printing function in Communication screen) Operation Modes Operation modes include Real Time mode, History mode, File mode. Choose the mode you want in Communication screen by clicking View to get in the chosen mode. Real Time mode: Real-time display the present reading in Communication screen. History mode: observe the previous data of readings; keep data logging. File Mode: open the saved data of readings. 4-9
23 Communication 4.12 Mode Resetting Execute View -> Reset function, then all the present data will be reset and recorded again, and the Mode will be returned to Real Time mode Choose operation mode and mode resetting. 2. Choose present displayed data (only available under History mode and File mode). 4-10
Power & Harmonics Analyzer
Power & Harmonics Analyzer PCE Instruments France EURL 76, Rue de la Plaine des Bouchers 67100 Strasbourg France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 info@pce-france.fr www.pce-instruments.com/french
More information3 PHASE POWER ANALYZER
SD card real time data recorder with harmonic measurement 3 PHASE POWER ANALYZER Model : DW-6095 Your purchase of this 3 PHASE POWER ANALYZER marks a step forward for you into the field of p r e c i s
More informationThree-Phase Power Quality Analyzer PowerPad Model 3945-B
Three-Phase Power Quality Analyzer PowerPad Model 3945-B Display and record waveforms, transients, trend data and events simultaneously! Wouldn t it be nice if you could look inside your electrical system
More informationThree-Phase Power Quality Analyzer PowerPad Model 3945
Three-Phase Power Quality Analyzer PowerPad Model 3945 Wouldn t it be nice if you could look inside your electrical system and see what s going on? Troubleshooting would be so much easier if you could
More informationPowerView for the EnergyPro
Data Analysis Software User's Guide PowerView User's Guide Copyright 2005 CANDURA INSTRUMENTS. All Rights Reserved. The information in this document is subject to change without notice. CANDURA INSTRUMENTS
More informationEnerscope-3S Studio. User Manual. Windows Software for Consulting and Analysing Data collected by Enerscope-3S Power Analyzer.
Enerscope-3S Studio Windows Software for Consulting and Analysing Data collected by Enerscope-3S Power Analyzer. User Manual ~ 1 ~ Table of Contents Paragraph Title Page 1 General Information 3 1.1 Main
More informationTHREE-PHASE POWER QUALITY ANALYZER
THREE-PHASE POWER QUALITY ANALYZER PowerPad Model 3945-B Display and record waveforms, transients, trend data and events simultaneously! Display real-time color waveforms measurements at a glance Direct
More informationDL150 Software Instructions
DL150 Software Instructions The DL150 USB software is a program for downloading stored data from the DL150 when it is connected to a PC or notebook computer. The data may be displayed graphically or as
More informationNanoWin. User's Manual - Rel. NW-1.1. Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers
NanoWin User's Manual - Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers Page 1 of 35 NanoWin Windows 9x and Windows NT 4.0 Data Management
More informationUser Guide. 3-Phase Power and Harmonics Analyzer / Datalogger MODEL PQ3470
User Guide 3-Phase Power and Harmonics Analyzer / Datalogger MODEL PQ3470 Table of Contents 1.0 INTRODUCTION 1-1 Features... 3 1-2 Safety... 4 2.0 SPECIFICATIONS 2-1 General Specifications... 5 2-2 Electrical
More informationSpectrometer Visible Light Spectrometer V4.4
Visible Light Spectrometer V4.4 Table of Contents Package Contents...3 Trademarks...4 Manual Driver and Application installation...5 Manual Application Installation...6 First Start of the Application...8
More informationpower quality Models 8230 & 8220
power quality Analyzer & METER Models 8230 & 8220 Measures up to 660Vrms or Vdc Measures current up to 6500Aac or 1400Adc Measures inrush current Displays Min, Max and Average Volts and Amps, Crest Factor,
More informationDigital Storage Oscilloscope
Digital Storage Oscilloscope GDS-3000 Series POWER ANALYSIS MANUAL GW INSTEK PART NO. 82DS-PWR00U01 ISO-9001 CERTIFIED MANUFACTURER April 2011 This manual contains proprietary information, which is protected
More informationDL160 Datalogger Software Guide
DL160 Datalogger Software Guide The Datalogger USB software is a program for collecting data from the DATA LOGGER when it is connected to a PC or Laptop computer. The data may be displayed graphically
More informationTrue RMS AC Voltage/Current Datalogger
User's Guide True RMS AC Voltage/Current Datalogger Model DL150 Introduction Congratulations on your purchase of this Voltage or Current datalogger. With this meter, you can monitor and log data over long
More informationModel POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
More informationSmart Data Link with KM Switch. User Manual MD-KM-PIP
Smart Data Link with KM Switch User Manual MD-KM-PIP Table of Contents Introduction...3 Specifications.3 Hardware Installation....4 AP Installation of USB Cable KVM with Data Link....5 The Icon Status...
More informationLadibugTM Visual Presenter Image Software User Manual
LadibugTM Visual Presenter Image Software User Manual 1 Contents 1. Introduction... 3 2. System requirement... 3 3. Install Ladibug TM... 4 3.1 In Windows XP/ Vista... 4 3.2 In Windows MAC... 6 4. Connection...
More informationQuick Start Guide. v1.1. Copyright 2011 AVID Technologies, Inc. Twinsburg, Ohio USA All Rights Reserved
Quick Start Guide v1.1 Copyright 2011 Twinsburg, Ohio USA All Rights Reserved Qi Sniffer Quick Start Guide v1.1 Page 2 Overview AVID Technologies Qi Sniffer is a diagnostic tool that can be used to passively
More informationPowerPad III Model 8336
Special product features POWER QUALITY ANALYZERS, METERS & LOGGERS Three-Phase Power Quality Analyzer CAPT 2GB MEMORY TREND RECORDING RE '''' TRANSIENTS PowerPad III Model SD card for trend data storage
More informationDigital Multifunction Meters. Digital Multifunction Meters
Digital Multifunction Meters Digital Multifunction Meters DIGITAL MULTIFUNCTIOL METERS SECTION INDEX 1. MFM 3410 3420 3430 3440 6100 & 2000 - Multifunctional Instrument Series 2. EM 3490, 3490SS, 3490DS
More informationPowerPad III Model 8435
Special product features POWER QUALITY ANALYZERS, METERS & LOGGERS Three-Phase Power Quality Analyzer 2GB MEMORY '''' PowerPad III Model CAPT TREND RECORDING RE TRANSIENTS SD card memory capacity for trend
More informationThree-Phase Power Quality Analyzer PowerPad Model 3945
Three-Phase Power Quality Analyzer PowerPad Model 3945 Wouldn t it be nice if you could look inside your electrical system and see what s going on? Troubleshooting would be so much easier if you could
More informationBFM-II BFM-II BRANCH FEEDER MONITOR. Highlights
BRANCH FEEDER MONITOR SATEC s is the second generation of Branch Feeder Monitor, providing energy management for multi-point power solutions. Ideal for both new and retrofit projects, the automatically
More information3 PHASE POWER ANALYZER
SD card real time data logger 3 PHASE POWER ANALYZER Model : DW-6092 Your purchase of this 3 PHASE POWER ANALYZER marks a step forward for you into the field of p r e c i s i o n measurement. A lthough
More informationTable of Contents. 1 Read This First 1. Instructions for Use Software Requirements Description of Additional Functions
Table of Contents Thank you very much for choosing the Control Software of Lumitester PD-20. All of this Instruction Manual must be read before operation of this product for safe and proper operation.
More informationDIN Rail Smart Meter for Single and Three Phase Electrical Systems
SDM630-Modbus V2 DIN Rail Smart Meter for Single and Three Phase Electrical Systems Measures kwh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, etc. Bi-directional measurement IMP & EXP Two pulse outputs
More informationNEW. DM-4 Power Quality Recorder. Rugged Remote User Interface with Memory TRUE
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com DM-4 Power Quality Recorder CAT 600V TRUE RMSz The DM-4 addresses the needs of the most demanding Power Quality professionals.
More informationPlug the USB interface of KAMKBMXBRNA gaming keyboard onto the free USB port of the computer. The
System Requirements: 1. Windows XP / Windows Vista / Windows 7 / Windows8 Operation System 2. Free USB 2.0 Port 3. CD-ROM Driver 4. 50 Mb available memory Windows XP / Windows Vista / Windows 7 / Windows
More informationPowerPad. Three-Phase Power Quality Analyzer. Power Quality Analysis Made Easy! Model 8335
Three-Phase Power Quality Analyzer PowerPad Model 8335 Power Quality Analysis Made Easy! Compact Easy-To-Use Shock-Resistant Direct access keys to display real-time waveforms, transients, inrush, harmonic
More informationfor Windows Version 2.xxx User Manual Rev. 2.0 Manual EM-LAB V2.0 1 of 41
for Windows Version 2.xxx User Manual Rev. 2.0 Manual EM-LAB V2.0 1 of 41 Second edition January 2014 Manual EM-LAB V2.0 2 of 41 This manual was compiled with utmost care. Errors can, however, not be excluded.
More informationMultifunction Transducer MT440
Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up
More informationMID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID
PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight
More informationUSER MANUAL 2012 V1.1
SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information
More informationPQ ANALYZER PROCUREMENT SAMPLE SPECIFICATION
Page 1 of 8 PQ ANALYZER PROCUREMENT SAMPLE SPECIFICATION SECTION XXXX POWER RECORDER MONITORING SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This Section includes Power Analysis and Recording (PAR) system, which
More informationUSB 2.0 All-in-One Cable
USB 2.0 All-in-One Cable 13335 Overview Congratulations on your purchase of the 133355, a USB file transfer cable. Nowadays, more and more people own more than two computers. Due to space limitations,
More informationUSB Temperature and Humidity Data Logger Instruction Manual
USB Temperature and Humidity Data Logger Instruction Manual 1 4 2 3 5 1. Display 2. Set key 3. + key 4. - key 5. USB port - 1 - 1. Temperature 4 2. MAX/MIN value 5 3. Humidity 1 2 3 4. Memory status 6
More informationInstructions for Use
Multilingual version 3.4 Lite version is intended for patient use only; Some physician features are disabled. Instructions for Use Table of Contents 1 Introduction... 1 2 Installing and Starting Software...
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # Series Power Analyzer Model 806 Instruction Manual
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-806 #61-807 800 Series Power Analyzer Model 806 Instruction Manual Table of Contents 1. Basic instructions 3 1.1. Introduction.
More informationNP40 - PORTABLE POWER QUALITY ANALYZER FEATURES
NP40 - PORTABLE POWER QUALITY ANALYZER NP40 power quality analyzer is the professional portable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data
More informationSDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems
SDM630M CT DIN Rail Energy Meter for Single and Three Phase Electrical Systems Measures kwh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc. Bi-directional measurement IMP & EXP Two pulse outputs
More informationU-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual
July, 2006 U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual CODE:GZ9100230793B 2000 2006 HORIBA, Ltd. As this software is only made for sample, all problems regarding this software is
More informationNEW! NP40 - PORTABLE POWER QUALITY ANALYZER FEATURES
NEW! NP40 - PORTABLE POWER QUALITY ANALYZER NP40 power quality analyzer is the professional portable device to measure and analyze the power system quality, supply the harmonics analysis and power quality
More informationB-Works 2 User s Guide
B-Works 2 User s Guide UMBWORKS 011413V1 Table of Contents 1. Introduction... 2 2. System Requirements... 2 3. Install B-Works 2... 3 4. Connection to the Hardware... 7 5. Start to Use B-Works 2... 7 6.
More informationQuick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP
Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP sa Contents Description...3 System Requirements...3 Installing
More informationGUI MANAGER USER GUIDE
GUI MANAGER USER GUIDE Rev. 2.0.0 December, 2012 www.tvielectronics.com 2211 Rayford Rd., Ste. 111-332 Spring, TX 77386 281-408-4051 281-408-4052 CONTENTS 1. DOCUMENT CONVENTIONS... 1 2. INSTALLATION INSTRUCTIONS...
More informationGuide to using Multi-Flo and Med-eBase Remote control
Page 1 of 17 Guide to using Multi-Flo and Med-eBase Remote control This document provides information on how to upgrade the Multi-Flo and Med-eBase software to enable remote control Multi-Flo functionality
More informationSmart KM Link User Manual
Smart KM Link User Manual Table of Contents Table of Contents Overview...3 System Requirements...3 Features...3 Support Language...3 Getting Started...4 Changing the Settings...6 Keyboard & Mouse Control
More informationDevices currently supported are: Fluke 43x-I V02.10 Fluke 1735 V01.10 Fluke VR 1710 V1.31
Readme.txt file FLUKE PowerLog Classic Software Version 4.4 Devices currently supported are: Fluke 43x-I V02.10 Fluke 1735 V01.10 Fluke VR 1710 V1.31 Fluke 345 V2.44 (and V1.02) PowerLog Classic is supported
More informationRanger PM6000. Power Quality Monitor
Ranger PM6000 Power Quality Monitor PM6000 The best value available for power quality monitoring The PM6000 is the most user-friendly, comprehensive, compact, cost-effective unit to be introduced to the
More informationmscope Low Cost, High Performance Automotive Scope
mscope Low Cost, High Performance Automotive Scope Description mscope is system specially designed and tested as a cheap, reliable and easy to use tool for use primarily by automobile service professionals.
More informationRGM180 Display Series
Quick Start Guide RGM180 Display Series BG0509 REV.A2 RGM180 QUICKSTART LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or
More informationUSB Keyboard and Mouse Console Switch User Manual
USB Keyboard and Mouse Console Switch User Manual (DS-16100) 1 INTRODUCTION The USB Keyboard and Mouse Console Switch provides a user to control two computers and associated display screens by using a
More informationEM300 Series. ET300 Series
EM300 Series and ET300 Series COMMUNICATION PROTOCOL Version 2 Revision 11 Index 1.1 Introduction... 3 1.2 MODBUS functions... 3 1.2.1 Function 03h (Read Holding Registers)... 3 1.2.2 Function 04h (Read
More informationPQM - Power Quality Monitoring
UMG 511 PQM - Power Quality Monitoring Class A power quality analyser according to IEC61000-4-30 The UMG 511 power quality analyser is particularly suitable for monitoring power quality according to standards
More informationC-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)
Model C-322 Datalogging Sound Level Meter Instruction Manual Tripod sold separately (Model BS-6) reedinstruments com Table of Contents Features... 3 Specifications... 3 Instrument Description...4-5 Operating
More information3 Phase Power Analyser / Data Logger
3 Phase Power Analyser / Data Logger Model LDW-6093K Your purchase of this 3 PHASE POWER ANALYZER marks a step forward for you into the field of precision measurement. Although this POWER ANALYZER is a
More information1000A 3-Phase Power Analyzer/Datalogger
User Guide 1000A 3-Phase Power Analyzer/Datalogger Model 382090 (60Hz) Model 382091 (50Hz) Introduction Congratulations on your purchase of the Extech 382090/382091 1000A 3-Phase Power Analyzer Datalogger.
More informationFluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.
Power Quality Analyzer EN June 2005 2001-2005 Fluke Corporation, All rights reserved. Printed in The Netherlands. All product names are trademarks of their respective companies. PLACING ORDERS AND GETTING
More informationAlpha-Numeric Display Pager MODEL :AL-A28. Gold Apollo Co., Ltd.
Alpha-Numeric Display Pager MODEL :AL-A28 PAGER PROGRAMMING GUIDE Gold Apollo Co., Ltd. Contents Contents GETTING STARTED... 1 EQUIPMENT REQUIRED... 1 EQUIPMENT SETUP... 1 INSTALLING PROGRAMMER SOFTWARE...
More informationMI 2792A PowerQ4 Plus
Ws E Plu N PowerQ MI 2792 PowerQ Plus Best Buy Class Featured Power Qualitynalyser! Now with GPS Module in the set! The MI 2792 PowerQ Plus is top of the range power quality analyser. With it s current
More informationUser's Guide. Model (60Hz) Model (50Hz) 1000A 3-Phase Power Analyzer/Datalogger NO.
User's Guide 1000A 3-Phase Power Analyzer/Datalogger Model 382090 (60Hz) Model 382091 (50Hz) P Q S NO. U12 Y-M U23 D-h U3 m-s 1 2 c I4 3 4 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument
More information3-Phase Power Analyzer/Datalogger
User Guide 3-Phase Power Analyzer/Datalogger MODEL PQ3450 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents 1.0
More informationOPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command
OPERATION MANUAL MV-410HS Layout Editor Version 3.0 - higher Command Command Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410HS
More informationMPQ2000. Portable Power Quality Analyzer. IEC Class A compliance. Powered off of phase A voltage ac/dc Vac and 1000 Vdc range
MPQ2000 IEC61000-4-30 Class A compliance Powered off of phase A voltage ac/dc 1000 Vac and 1000 Vdc range Real time scope and DVM Connection verification On-board data analysis DESCRIPTION The Megger MPQ2000
More informationInstruction Manual HIOKI Standby Power Measurement Software
Instruction Manual HIOKI Standby Power Measurement Software This manual explains the free software (HIOKI Standby Power Measurement Software) for the HIOKI Power Meter series only. Please refer to the
More informationNEMO HD MULTI-FUNC METER BASE (MF96001)
NEMO HD MULTI-FUNC METER BASE (MF96001) Quick and easy to install Compact modern design High accuracy monitoring and measurement to IEC 62053-21 Easy to read and configure Options for remote communication
More informationTROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON
TROVIS-VIEW 4 Software TROVIS 6661 Operating Instructions Electronics from SAMSON EB 6661 EN Edition January 2015 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result
More informationPITE 3561 Power Quality Analyzer User Manual
User Manual P-120907-V1.4 www.esis.com.au Ph 02 9481 7420 Fax 02 9481 7267 esis.enq@esis.com.au Catalogue 1. INTRODUCTION... 3 1.1 Packing List... 3 1.2 Safety Information... 4 1.3 Operating Precautions...
More information1200A 3-Phase Power Analyzer/Datalogger
User s Manual 1200A 3-Phase Power Analyzer/Datalogger MODEL 382100 Table of Contents 1.0 INTRODUCTION 1-1 Features.... 3 1-2 Safety...4 2.0 SPECIFICATIONS 2-1 General Specifications....5 2-2 Electrical
More informationCVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro
CVI SPECTRAL PRODUCTS 111 Highland Drive Putnam CT, 06260 (860) 928-5834 SM32Pro 2.8.28 Table of Contents Warranty and Liability 1 Quick Start Installation Guide 2 System Requirements 3 Requirements for
More informationUMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)
UMG 605 UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC) The UMG 605 power quality analyzer is particularly suitable for monitoring power quality according to standards such as EN 50160. All power
More informationB+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.
SDM630 Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 203 V. Important Safety Information is contained in the Maintenance section. Familiarize yourself with this
More informationManual for MantraJet 1100 CD/DVD auto-printer
Manual for MantraJet 1100 CD/DVD auto-printer Rev 1.03 September 7, 2010 Table of contents Specifications...3 Unpacking MantraJet 1100...4 Quick installation reference MantraJet 1100...7 Installation of
More informationALARM-CLOCK / RADIO DIGITAL PHOTO FRAME
ALARM-CLOCK / RADIO DIGITAL PHOTO FRAME English Ref.: CPNR2.0 - OPERATION MANUAL- TECHNICAL DATA 1. Display screen: 1.5 CSTN LCD 2. Memory: 1MB Nor flash 3. Maximum picture quantity: 58 pieces 4. Picture
More informationQuick Start for MK30XEMETER Project name: MQX-Based Kinetis (MK30X256) Single-Phase Electricity Meter Reference Design
Quick Start for MK30XEMETER Project name: MQX-Based Kinetis (MK30X256) Single-Phase Electricity Meter Reference Design IMM Solutions Roznov (CZ) Written by: Luděk Šlosarčík Page 1 of 9 23 May 2011 1. INTRODUCTION
More informationRelease Notes. R&S ES-SCAN EMI Measurement Software
Release Notes Revision: 09 R&S ES-SCAN EMI Measurement Software Software Release V2.70 These Release Notes describe the following types and options of the R&S ES-SCAN EMI Measurement Software. R&S ES-SCAN,
More informationContents Introduction..2 System Requirements 2 Package Contents..3 PC Camera Introduction 3 Set up PC Camera.4 Software Installation Arcsoft
0 Contents Introduction..2 System Requirements 2 Package Contents..3 PC Camera Introduction 3 Set up PC Camera.4 Software Installation Arcsoft VideoImpression 2.0.5 Arcsoft PhotoImpression 5.0.7 Snapshot
More informationDCRJ8 DCRJ12 Automatic power factor regulator
I 148 GB 11 05 DCRJ8 DCRJ12 Automatic power factor regulator REMOTE CONTROL SOFTWARE MANUAL Summary Introduction... 2 Minimum resources of the PC... 3 Installation... 3 Activation of the PC-DCRJ connection...
More informationHow to install or remove the ISaGRAF development platform properly
How to install or remove the ISaGRAF development platform properly By grady_dun@icpdas.com For the ICP DAS ISaGRAF PACs and the ISaGRAF Workbench software to operate properly, it is imperative that each
More informationPower Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser
Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser 4 Target Max. Demand (MD) Load Shed Controller Up to 64 loads may be shed to
More informationFU2200B FU2200B V Ethernet Power Meter with Data Logger. Features. Applications
FU2200B 0-800V Ethernet Power Meter with Data Logger FU2200B is a three-phase multifunction power and energy meter manufactured by GFUVE. The meter provide excellent value for monitoring power and energy
More informationWARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.
55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger
More informationTouchKit TouchScreen Controller User Guide for Windows 2000 / XP Version: 3.2.4
TouchKit TouchScreen Controller User Guide for Windows 2000 / XP Version: 3.2.4 TouchKit Guide for Win2000/XP v3.2.4 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER...2 1.1 CONTROLLER...2 1.2 SPECIFICATIONS
More informationPower analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B A) MEASURING EQUIPMENT
Power analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B01-03-18A) MEASURING EQUIPMENT 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of
More informationEXPRESS. Users Guide. Version 3.5
EXPRESS Users Guide Version 3.5 Table of Contents 1 System Overview... 3 2 System Requirements... 3 3 Contents in ECMTUNE System Box... 3 4 Installation Information... 4 5 Registration Information... 7
More informationUSB Serial Converter
USB Serial Converter Copyright Statement No part of this publication may be reproduced in any form by any means without the prior written permission. Other trademarks or brand names mentioned herein are
More informationEM6400 series Multi-Function meters
6400 series Multi-Function meters 1 Digital display & Analog load bar indicators 2 Bright Red LED display 3 Global: CE, UL marks 4 Universal Demand Monitoring Quick and easy installation Turbo Key 6400
More informationfor demos & updates
Check www.velleman.be for demos & updates MINIMUM SYSTEM REQUIREMENTS : IBM-compatible PC Windows 95, 98, ME (Win2000 / XP or NT possible) SVGA display card (min. 800x600 for Windows) mouse free printer
More informationUSER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A.
USER MANUAL TM S6000 / S7000 S8000 / S9000 Associated Research, Inc., 2005 13860 West Laurel Drive Lake Forest, Illinois, 60045-4546 U.S.A. Item 38086 Ver 1.04 Printed Nov 15, 2005 TABLE OF CONTENTS INSTALLATION
More informationWiRobot TM DRK6000 QUICK START
WiRobot TM DRK6000 QUICK START CAUTION: Before You Begin Please have the battery charged for 5 hours before usage. SYSTEM REQUIREMENTS: The PC requirements in using the WiRobot system are: PIII 550MHz
More informationCVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)
Power analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B01-03-16B) 2 Safety precautions Follow the warnings described in this manual with the symbols shown below. DANgeR Warns of a risk, which could
More informationShort form Manual ANALYST3Q and WinA3Q
Short form Manual ANALYST3Q and WinA3Q Contents: 1 Installation of WinA3Q...1 2 Installation of PQDIF-Browser TOP 2000...3 3 Recording of measurement data with ANALYST 3Q...8 4 Reading of measured values...10
More informationPower Vision 1.5 (Cod )
ELECTRICAL NETWORK ANALYSIS SOFTWARE Power Vision 1.5 (Cod. 775 353) USER S MANUAL (Cod. M 981 358 / 02 D) 2002 - CIRCUTOR, S.A. INDEX 1.- POWER VISION SOFTWARE INSTALLATION...4 2.- INTRODUCTION TO POWER
More informationVoltage Transducer UMT516 / MT516
Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication
More informationDEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S
Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,
More informationENERGY MASTER. Rev. 1.2 Date: 02/09/10
Rev. 1.2 Date: 02/09/10 ENERGY MASTER Index: General Description...3 Composition of ENERGY MASTER Basic Kit...3 ENERGY MASTER Installation...4 Panel Installation:...4 DIN-rail Installation:...4 Electrical
More information1.3 MegaPixel Auto Focus Webcam USER MANUAL
2516524 1.3 MegaPixel Auto Focus Webcam USER MANUAL Industry Canada - ICES-003 CAUTION To comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules, this device must only
More informationCopyright Autodesk, Inc.
Customer and Administration Building, Ditzingen, Germany - Design by Barkow Leibinger Architects Copyright 2003-2008 Autodesk, Inc. Table of Contents 1 Introduction... 3 What is Facility Manager?... 3
More informationIMC Intelligent Analysis Report v7.1 (E0301P02) Copyright (c) 2015 Hewlett-Packard Development Company, L.P. and its licensors.
IMC Intelligent Analysis Report v7.1 (E0301P02) Copyright (c) 2015 Hewlett-Packard Development Company, L.P. and its licensors. Table of Contents 1. What's New in this Release 2. Problems Fixed in this
More information