for Windows Version 2.xxx User Manual Rev. 2.0 Manual EM-LAB V2.0 1 of 41

Size: px
Start display at page:

Download "for Windows Version 2.xxx User Manual Rev. 2.0 Manual EM-LAB V2.0 1 of 41"

Transcription

1 for Windows Version 2.xxx User Manual Rev. 2.0 Manual EM-LAB V2.0 1 of 41

2 Second edition January 2014 Manual EM-LAB V2.0 2 of 41

3 This manual was compiled with utmost care. Errors can, however, not be excluded. The editor and author both cannot accept any responsibility or liability for errors and consequences thereof. Unauthorized copying and sales of this product are considered as plagiarism and will be subject to prosecution. All programs and names are trademarks or registered trademarks of the respective companies. Copyright 2014 FRANKONIA EMC Test-Systems GmbH, Forchheim. All rights reserved. Copyright 2014 National Instruments Corporation. All rights reserved. Explanations of signs: Important information or examples General danger Danger to health of person Danger of equipment Manual EM-LAB V2.0 3 of 41

4 Table of Contents 1. Important information Foreword Conformity with standards Hardware and software requirements Installation of EM-LAB De-Installation How to get well skilled and learn about EM-LAB Start of EM-LAB Program control File Load settings Save settings Display results Export results Options Modify start window Path settings Print Exit Edit Limit lines Antenna- / Clamp correction LISN / Probe / Network Cable correction Gain-/attenuation unit Correlation Preferences Devices Receiver Mast-/Turn table controller Scan Graphics Zoom in/zoom out of a graphic area Testing (Scans) Start Stop - Pause Single measurement Sweep measurement Help Product support Manual EM-LAB V2.0 4 of 41

5 Figure of Contens Figure 1: Installation of EM-LAB... 9 Figure 2: Start window of EM-LAB Figure 3: Start window of EM-LAB Figure 4 : Main menu with icon bar Figure 5 : Current settings Figure 6 : Pull down menu File Figure 7 : Settings under Options Figure 8 : Print results or save as file Figure 9 : Edit limit lines Figure 10 : Edit antenna or clamp correction Figure 11: Correction values for auxiliary devices Figure 12: Cable attenuation correction Figure 13: Amplifier/attenuation correction Figure 14: Correlations values Figure 15 : Settings of receiver Figure 16 : Setup of mast and turn table controller Figure 17 : Scan settings Figure 18 : Detectors/Limits/Corrections and data reduction Figure 19 : Scan settings for pre-programed test runs Figure 20 : Graphic settings Figure 21 : Information for the test documentation Figure 22 : Automatic search for receiver at existing interfaces Figure 23 : Window during scan Figure 24 : Window during final scan of critical frequencies Figure 25 : Window after a complete scan Figure 26 : Possibility to evaluate critical frequencies Figure 27 : Window of single measurement Figure 28 : Window in sweep measurement Manual EM-LAB V2.0 5 of 41

6 1. Important information Operation of this system or single units for measuring can causes high frequency signals with strong electromagnetic fields. National and international safety regulations as well as operating instructions of the individual components have to be carried out absolutely consequent. In the case of inappropriate use people can be endangered, things can be damaged and the use of other devices might be disturbed. The author and supplier herewith exclude any liability for damages of any kind caused by working with this software. Manual EM-LAB V2.0 6 of 41

7 2. Foreword With the software EM-LAB you have a powerful tool for measuring radio disturbance of conducted emission (Conducted Disturbance and Disturbance Power) and high frequent fields (Radiated Disturbance) according to the CIPSR standard. This program also delivers a set of pre-programed, conform measurement runs to ease the handling and shorten the time until the start of the measurement. Therefor also stuff without special training and knowledge in the emissions measurement procedures and standards are able to measure emission according to the standards. For the automation of the measurement several auxiliary equipment is supported like LISN, Turn table controller, mast controller. For detailed examination of emissions sources the software gives you the possibility to measure single frequencies or an analyzer mode for a defined frequency band. Besides the measurement representing, processing and giving out the results is possible anywhere. Basic knowledge of Windows-handling is assumed. Manual EM-LAB V2.0 7 of 41

8 3. Conformity with standards This software version and testing configuration are in conformity with the following standards: EM-LAB IEC/CISPR 11: A1:2010 DIN EN 55011:2011 IEC/CISPR 14: A1: A2:2011 DIN EN :2012 IEC/CISPR 15: A1: A2:2002 DIN EN 55015:2003 IEC/CISPR 22:2008 DIN EN 55022: Hardware and software requirements Operating system CPU Fee user memory Free hard disk capacity Monitor resolution Windows 7 SP1 32/64-bit Windows Vista SP2 32/64-bit Windows XP SP3 > Intel Pentium 4 1,6 GHz > 2 GB RAM > 500 MB Monitor size > 19 Interfaces > 1024 x 768, 32-bit color depth Depending on the used devices - with GPIB devices a GPIB adapter from NI with the NI software is assumed - with serial interface at least a baud rate of Baud - with USB interface USB 2.0 or higher Manual EM-LAB V2.0 8 of 41

9 5. Installation of EM-LAB If you are using a GPIB interface you have to install first the GPIB converter and its software. Please refer to the manual of the GPIB interface manufacturer. The user might have the need of administrator privileges to install and run the software. To install EM-LAB take care of the following items. Start Windows. Insert the CD-ROM or extract the downloaded file in a directory Start the installation with a double click on SETUP.EXE. During the installation you can change the installation directory (see figure 1). Figure 1: Installation of EM-LAB After installation EM-LAB creates a program folder with the symbol EM-LAB. Manual EM-LAB V2.0 9 of 41

10 In the installation directory sub directories were created for - Limit files - Correction files - Setup files - Result files Due to lack of space us it can happen that only the main program was sent to you without the NI-VISA RunTime-Engine (NI-VISA Run-Time Engine 5.4). This driver can be loaded from the NI homepage ( if it is not already installed on your PC. Copyright 2014 National Instruments Corporation. All rights reserved. 6. De-Installation In case you need to uninstall EM-LAB from your system use the uninstaller supplied under Add or remove software in the Control panel. 7. How to get well skilled and learn about EM-LAB The structure and handling of the program is very easy to understand. Working with the program is the best method to learn the way to use it. In case any additional explanation is necessary there are several possibilities: This manual, which is supplied together with the software For the single menu items you found help in the online help (Help in the menu bar). Context sensitive help is available by activating the respective field and pressing the F1 -button on the keyboard or by clicking the right-hand mouse button (see figure 2). If problems cannot be solved by using the previous methods, contact our local distributor. Manual EM-LAB V of 41

11 8. Start of EM-LAB Start EM-LAB from the windows Start menu or double-click the icon. A start screen will occur during start phase. You can select the language (German or English) and you have the possibility to choose between the pre-programed test runs or the advanced mode Figure 2: Start window of EM-LAB Manual EM-LAB V of 41

12 With a left mouse click on the button Pre-programmed test runs a list opens with standardized emission measurements. Here you will find the important standards for the measurement of radio disturbance of conducted emission (Conducted Disturbance and Disturbance Power) and high frequent fields (Radiated Disturbance). All necessary parameters will be set for the test runs and only a few can be partly changed. Therefore a standardized measurement can be done without a deep knowledge of the standards. Figure 3: Start window of EM-LAB These pre-programed test runs cannot be changed but you can add a self-defined parameter setup file to this list which will be available later on in this selection. You will find this entry under the header User defined Manual EM-LAB V of 41

13 9. Program control This software is controlled via menu or the icon bar under the menu bar. Tooltips of the icons are displayed to show the function behind. Figure 4 : Main menu with icon bar The current scan settings are shown in the below, left program window. Figure 5 : Current settings Manual EM-LAB V of 41

14 10. File Figure 6 : Pull down menu File Load settings This menu item allows you to load the setup files already installed or stored. In the *.sek files are settings for the used devices (receiver, mast-/turn table controller, LISN, etc.), and the scan settings, which includes the limit lines. All necessary setups to run a complete measurement Save settings All parameters of the current used devices (receiver, mast-/turn table controller, LISN, etc.), scan settings and limit lines are saved with this menu item. All necessary setups to run a complete measurement Display results All saved measurements can be displayed with this function. Manual EM-LAB V of 41

15 10.4. Export results Results can be exported into files with another file format. Thus it gives you the possibility to create your own evaluations or documentations. At the moment there are an export to ASCII format and ASCII format with delimiters for easy import to Microsoft Excel Options Modify start window In the start window you can change the button color, text color in those buttons, the logo file and background picture. Figure 7 : Settings under Options Manual EM-LAB V of 41

16 Path settings There are default directories for limit files, correction files, setup files and results files. Those default directories which are already created during the installation could be changed here Print Results are printed directly to a printer or stored in a file in Bitmap or Jpeg format. Figure 8 : Print results or save as file Exit Exits the program and returns to the OS. Manual EM-LAB V of 41

17 11. Edit Limit lines Under this menu item the limit lines are created and saved or existing limit lines are modified. Figure 9 : Edit limit lines Insert: Delete: Save: Inserts the given frequency and its corresponding value in the right position in the list. Deletes the marked entry in the list Saves the complete list in a file with the extension *.lim. Manual EM-LAB V of 41

18 Cancel: New: Load: All changes are ignored. Deletes all previous values to create a new limit line. Loads an existing limit line from a *.lim file. Manual EM-LAB V of 41

19 11.2. Antenna- / Clamp correction Correction factors of antennas or clamps can be edited here. Additional information for the documentation can be added. Figure 10 : Edit antenna or clamp correction Insert: Delete: Save: Cancel: Inserts the given frequency and its corresponding value in the right position in the list. Deletes the marked entry in the list Saves the complete list in a file with the extension *.kor. All changes are ignored. Manual EM-LAB V of 41

20 New: Load: Deletes all previous values to create a new correction list. Loads an existing correction list from a *.kor file. Manual EM-LAB V of 41

21 11.3. LISN / Probe / Network Correction factors of LISN / probes or networks can be edited here. Additional information for the documentation can be added. Figure 11: Correction values for auxiliary devices Manual EM-LAB V of 41

22 11.4. Cable correction Correction factors of the used cables can be edited here. Additional information for the documentation can be added. Figure 12: Cable attenuation correction Manual EM-LAB V of 41

23 11.5. Gain-/attenuation unit Correction factors of the used amplifiers/attenuators can be edited here. Additional information for the documentation can be added. Figure 13: Amplifier/attenuation correction Attenuation values have to be negative numbers, amplifier value have to be positive numbers. Manual EM-LAB V of 41

24 11.6. Correlation Correlation factors can be edited here. Figure 14: Correlations values The value in the list are added to the measured receiver values. Manual EM-LAB V of 41

25 12. Preferences Here settings to the used devices, the measuring runs (scans) and the diagrams are made Devices Receiver Figure 15 : Settings of receiver At first the used receiver has to be selected from the list. If the receiver is not in the list it is not supported yet. On request a driver for not yet existing equipment can be programmed. As interface serially, USB, GPIB and Ethernet are supported. Manual EM-LAB V of 41

26 The address of the device is selected under Address. For most devices this address can be found from the program during the start of a measurement run and will be automatically registered after successful connection. Also serial number and firmware version are automatically detected and registered if the device is able to provide this information. If not, those fields can be edited manually. Dates of calibration are used for the documentation. Therefor the traceability could be seen easily. Additional parameters are device specific and could be set under Preferences. In the picture above there is the possibility to activate a pulse limiter or to make the emission hearable with a built-in demodulator. Manual EM-LAB V of 41

27 Mast-/Turn table controller Figure 16 : Setup of mast and turn table controller Controller selection: Separate mast and turn-table controller can be selected here. The corresponding address of the serial or GPIB interface must be inserted. Manual EM-LAB V of 41

28 Mast settings: Max. height: Min. height: Speed: Antenna tilting: Limit of the maximum antenna height. Limit of the minimum antenna height. Speed during the positioning of the antenna. Antenna tilting can be activated. Tilting of the antenna is adjusted according to its height in that way that the antenna is always pointing on the same point of the EUT. This function is only available with mast that support antenna tilting. Manual control Manual controlling of the mast can be activated here. During the positioning of the mast person or objects can be damaged close to the antenna. Make sure that there is enough space around the mast device and that no person is close to the mast device. Horizontal and vertical polarization can be chosen. The desired height is entered in the field Demand height. The current height is shown in the field Actual-height. With Start and Stop the desired position will be initiated or the movement will be stopped. Manual EM-LAB V of 41

29 Turntable settings: Max. angle: Limit of the maximum turntable angle. Min. angle: Speed: Limit of the maximum turntable angle. Speed during the positioning of the turn table. Manual control Manual controlling of the turntable can be activated here. During the positioning of the turntable person or objects can be damaged close to the turntable. Make sure that there is enough space around the turntable and that no person is close or on the turntable. The desired angle is entered in the field Demand angle. The current angle is shown in the field Actual-angle. With Start and Stop the desired position will be initiated or the movement will be stopped. Height priority, Pol. priority, turntable priority: Priority between height, polarization or turntable can be chosen. During the automatic measurement the mast (Mast priority active), polarization (pol. Priority active) or turntable (turntable priority active) will be initiated first to find the maximum emission. Settings of mast and turntable can be saved or loaded. File extension *.msu. Manual EM-LAB V of 41

30 12.2. Scan The settings under Scan are defining the test run. Up to 5 scan columns can be defined which are processed automatically one after the other. Figure 17 : Scan settings Start, Stop frequency, step size and the time for pre-scan and final-scan can be edited. With a double left click on the fields Detector and Limits a new window pops up for the settings of detectors, limit lines, correction files and data reduction. During the pre-scan up to 6 detectors can be chosen simultaneously. For the final scan only two detectors are allowed. Selection of limit files, corrections files is done with double left click in the corresponding field. Then a file select box opens for chosen the desired file. The directories which were preselected in the Options menu are shown first. Manual EM-LAB V of 41

31 Data reduction Acceptance level: Range: Defines the proximity to the limit from which a final scan has to be made. The whole frequency range is divide in a number of subranges. In each sub-range x numbers of frequencies are finally measured, if necessary. x = Max value / Range This assures that not only a narrow range with high amplitudes is measured but also among the complete frequency range final measurements are made. Max value: Verify immediately: Autom. final meas.: Maximum number of frequencies to be finally measured Final measurement of critical frequencies starts immediately. If active a final scan starts automatically after a pre-scan (if necessary), without user activity. Figure 18 : Detectors/Limits/Corrections and data reduction If you chose a pre-programed measurement run in the start window you cannot Manual EM-LAB V of 41

32 change several parameters in the scan setting window. Those parameters are dimmed. Figure 19 : Scan settings for pre-programed test runs These settings cannot be stored. Manual EM-LAB V of 41

33 12.3. Graphics With this function you can change the view of the graphic during or after a measurement. Figure 20 : Graphic settings XMode: XGrid: YGrid: Representation between linear and logarithm. On and off X-grid On and off Y-grid Manual EM-LAB V of 41

34 Y-Scaling: Manual: Automatic: Fixed input of Y-axes limitations. Software calculates best representation in Y-Axe automatically. Name: Plot Form: Point Form: Line Form: Color: Activates the curve you want to change. Changes curve styles (thin line, points connected, single points, vertical bars, thick lines, thin steps, thick steps) Changes point styles (empty square, solid square, diameter form, simple point, no point) Changes line styles (solid, dash, dot, dash dot, dash dot dot) Setting of color to the selected curve. Visible / invisible: You can hide or show curves Limit lines annotations: Activates or deactivates line annotations of the limit lines Zoom in/zoom out of a graphic area Zoom in Press <Ctrl> and click and hold the left mouse button to define the first corner of the box. Drag the mouse to define the opposite corner of the rectangle. When you are satisfied with the new boundaries of the graph, release the mouse button Zoom out To zoom out, press <Ctrl> and click and hold the right mouse button. The resolution incrementally decreases by 10% along the zoomed axes. You also can undo up to 25 of the most recent pans or zooms by pressing <Ctrl-Space> to reverse each successive change. Manual EM-LAB V of 41

35 13. Testing (Scans) Measurements can be started with the menu entry Testing Start, with the function key F2 or with the start icon in the icon bar Start Stop - Pause After the start the window for the test documentation pops up. Figure 21 : Information for the test documentation Manual EM-LAB V of 41

36 After that the receiver is searched at the available interfaces. Figure 22 : Automatic search for receiver at existing interfaces The measurement is started after a successful connection. Figure 23 : Window during scan Now a pre-scan with a reduced measuring time is started which scans the defined frequency range. Based on the results of the pre-scan and the settings in the data reduction critical frequencies are calculated and at those frequencies a final measurement with the standard measurement time and detector is made. Manual EM-LAB V of 41

37 The critical frequencies and their values are shown in the table on the right side of the window and marked red if the value is above the limit line. Figure 24 : Window during final scan of critical frequencies After finishing the measurement a marker is shown on the screen for evaluation of the emission values. The cursor can be moved with mouse in a free mode manner or with the cursor keys along the curve. Manual EM-LAB V of 41

38 Figure 25 : Window after a complete scan With a double click on a critical frequency in the table you can select if you want to make an evaluation for this special frequency (Single freq.) or a sweep around that frequency (Spectrum analyzer). Figure 26 : Possibility to evaluate critical frequencies Manual EM-LAB V of 41

39 13.2. Single measurement Figure 27 : Window of single measurement In this window you can make measurement at a single frequency. All available detectors were measured and displayed, if it s possible. All necessary settings can be accomplished during the measurement. As soon as the measured values are valid they were shown and updated regularly according to the chosen hold time Hold time Sweep measurement With this function it is possible to use the receiver as a spectrum analyzer. Set the start and stop frequency or chose the range with Center und Span. Now the receiver sweep continuously through this frequency range and the software shows the emission values until you push the Back button or set the option Stop after sweep. Manual EM-LAB V of 41

40 Figure 28 : Window in sweep measurement With the option Maximum Curve and Minimum Curve in the field Tools you can include a second and third line, which are showing the minimum and maximum emission level overall sweeps. Modification on the EUT and their effect on the emission could be easily seen. Up to two limit line can be activated in the graphics. So you can check also during the sweep if you are under the limits or not. Also two additional correction factors can be loaded (for example antenna correction, attenuation correction) which are calculated with the row signals of the receiver. If the sweep mode was started from the normal scan all the parameters from the scan can be used (Take over data from scan table). Manual EM-LAB V of 41

41 14. Help EM-LAB use two online-help systems. For each point of the menu there is a description in Help in the menu bar. For the parameters in the parameter windows you can select the online help via right mouse click of F1-key on the active field. 15. Product support Even today s software programs are not faultless by 100 % and therefore you might detect errors in EM-LAB. Maybe you have ideas for improvements, have specific requirements or would prefer use of a device that is not mentioned in the list? In all of these cases please do not hesitate to contact us directly. Any comments and proposals from your side will be welcome. Frankonia EMC Test-Systems GmbH Daimlerstraße Forchheim Tel. +49(0)9191/ Fax +49(0)9191/ info@frankonia-emv.com Internet: Manual EM-LAB V of 41

TPEditor User Manual

TPEditor User Manual Table of Contents TPEditor User Manual Chapter 1 TPEditor Operation... 1-1 1-1 Recommended System Requirements... 1-1 1-2 TPEditor Software Installation... 1-1 1-3 Basic Introduction... 1-6 1-4 Skills

More information

Operating Instructions / User manual. IRSoft. Version 2.0. Documentation software for ERSA Rework Systems. ERSA GmbH

Operating Instructions / User manual. IRSoft. Version 2.0. Documentation software for ERSA Rework Systems. ERSA GmbH Operating Instructions / User manual IRSoft Version 2.0 Documentation software for ERSA Rework Systems ERSA GmbH Wertheim / Main July 2002 ERSA has taken great care in the preparation of this Users Guide,

More information

VANGUARD LOAD TAP CHANGER ANALYZER (LTCA) VERSION 2.xx SOFTWARE MANUAL. LTCA-10, LTCA-40, WRM-10P, WRM-40, TRM-20, TRM-40, TRM-203, and TRM-403

VANGUARD LOAD TAP CHANGER ANALYZER (LTCA) VERSION 2.xx SOFTWARE MANUAL. LTCA-10, LTCA-40, WRM-10P, WRM-40, TRM-20, TRM-40, TRM-203, and TRM-403 VANGUARD LOAD TAP CHANGER ANALYZER (LTCA) VERSION 2.xx SOFTWARE MANUAL For Use with Vanguard s LTCA-10, LTCA-40, WRM-10P, WRM-40, TRM-20, TRM-40, TRM-203, and TRM-403 Load Tap Changer Analyzers and Winding

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

POSITIONING DEVICES AND ACCESSORIES FOR ANECHOIC CHAMBERS, OATS AND SHIELDED ROOMS

POSITIONING DEVICES AND ACCESSORIES FOR ANECHOIC CHAMBERS, OATS AND SHIELDED ROOMS Antenna masts, Turntables, Controllers, Shielded video systems, Shielded audio systems and Optic converters POSITIONING DEVICES AND ACCESSORIES FOR ANECHOIC CHAMBERS, OATS AND SHIELDED ROOMS FAM - FULLY

More information

testo Comfort Software Professional 4 Instruction manual

testo Comfort Software Professional 4 Instruction manual testo Comfort Software Professional 4 Instruction manual 2 1 Contents 1 Contents 1 Contents...3 2 About this document...5 3 Specifications...6 3.1. Use...6 3.2. System requirements...6 4 First steps...7

More information

Q-Lab Software OPERATION MANUAL

Q-Lab Software OPERATION MANUAL Q-Lab Software OPERATION MANUAL Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed products

More information

R&S IMS Software Configuration and System Calibration according to IEC / EN (conducted Immunity)

R&S IMS Software Configuration and System Calibration according to IEC / EN (conducted Immunity) Products: R&S IMS, R&S NRP-Z91 R&S IMS Software Configuration and System Calibration according to IEC / EN 61000-4-6 (conducted Immunity) Application Note This application note describes the software configuration,

More information

Central Management Software for NVR-915 / NVR-1615 CV5-M256

Central Management Software for NVR-915 / NVR-1615 CV5-M256 Central Management Software for NVR-915 / NVR-1615 Table of Contents Chapter 1. Main Console... 4 1.1 Tool Bar... 4 1.2 NVR List... 5 1.3 Division List... 7 1.4 Group List... 9 1.5 PTZ Panel...11 1.6 Operation

More information

Software for Observation and Measurement SGMMS V2.6. Users Manual

Software for Observation and Measurement SGMMS V2.6. Users Manual AFM45-S03-12402 Software for Observation and Measurement SGMMS V2.6 Users Manual SIGMAKOKI Co., LTD. CONTENTS 1 OVERVIEW... - 3-2 BEFORE USE... - 3-2-1 OPERATIONAL ENVIRONMENT...- 3-2-2 INSTALLATION PREPARATION...-

More information

EMC Measurement Software EMC32

EMC Measurement Software EMC32 EMC Measurement Software EMC32 For use in development, for compliance and batch testing Flexible Modules for measuring electromagnetic interference (EMI) and electromagnetic susceptibility (EMS) Support

More information

GL500A Application Manual

GL500A Application Manual GL500A Application Manual Main Functions A Variety of Waveform Displays Y-T, X-Y, and FFT waveforms can be displayed on large, easy-to-read screens. Dual-screen Event and Current Data Replay Current data

More information

U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual

U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual July, 2006 U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual CODE:GZ9100230793B 2000 2006 HORIBA, Ltd. As this software is only made for sample, all problems regarding this software is

More information

Logger Pro 3. Quick Reference

Logger Pro 3. Quick Reference Logger Pro 3 Quick Reference Getting Started Logger Pro Requirements To use Logger Pro, you must have the following equipment: Windows 98, 2000, ME, NT, or XP on a Pentium processor or equivalent, 133

More information

Panaboard Overlayer User's Guide. Image Capture Software for Electronic Whiteboard (Panaboard)

Panaboard Overlayer User's Guide. Image Capture Software for Electronic Whiteboard (Panaboard) Panaboard Overlayer User's Guide Image Capture Software for Electronic Whiteboard (Panaboard) Contents Introduction... 3 Functional Overview... 3 Operation Flow... 3 Abbreviations... 4 Trademarks... 4

More information

User Guide 701P Wide Format Solution Wide Format Scan Service

User Guide 701P Wide Format Solution Wide Format Scan Service User Guide 701P44865 6204 Wide Format Solution Wide Format Scan Service Xerox Corporation Global Knowledge & Language Services 800 Phillips Road Bldg. 845-17S Webster, NY 14580 Copyright 2006 Xerox Corporation.

More information

PMM IMMUNITY SUITE. User Manual DATA ACQUISITION PROGRAM FOR RADIATED & CONDUCTED IMMUNITY TESTS

PMM IMMUNITY SUITE. User Manual DATA ACQUISITION PROGRAM FOR RADIATED & CONDUCTED IMMUNITY TESTS http://www.narda-sts.it NARDA Safety Test Solutions S.r.l. Socio Unico Sales & Support: Via Leonardo da Vinci, 21/23 20090 Segrate (MI) - ITALY Tel.: +39 02 2699871 Fax: +39 02 26998700 Manufacturing Plant:

More information

General Specifications

General Specifications General Specifications DAQManager Data Management Software for Paperless Recorders [Release: R2] Overview DAQManager is a software program that enables you to manage measured data from Daqstation and MVAdvanced

More information

SICAT SUITE VERSION 1.0. Instructions for use English

SICAT SUITE VERSION 1.0. Instructions for use English SICAT SUITE VERSION 1.0 Instructions for use English Table of contents Table of contents 1 System requirements... 4 2 Overview of... 6 3 Differences between full featured mode and viewer mode... 8 4 Safety

More information

SPRECON-E Display Editor

SPRECON-E Display Editor SPRECON-E Display Editor Version 2.0b USERS MANUAL 94.2.912.60en 09/2004 ISSUE A page 2 / 61 Business Sector Enery Station Automation (ENA) [Power systems automation] Sprecher Automation GmbH Franckstrasse

More information

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13 Thank you for buying Data Analysis Software. In order to use this software correctly and safely and to prevent trouble, please read this manual carefully. Notice 1. No part of this manual can be reproduced

More information

MESURgauge Software. User s Guide

MESURgauge Software. User s Guide MESURgauge Software User s Guide Thank you Thank you for purchasing MESURgauge software, a data collection and analysis program developed to: Measure Collect data from digital force gauges, torque gauges,

More information

User Manual. Central Monitoring Software for TER-series recorders. CenPro

User Manual. Central Monitoring Software for TER-series recorders. CenPro EN User Manual Central Monitoring Software for TER-series recorders CenPro Contents CENPRO USER MANUAL 1 PC REQUIREMENT 3 2 INSTALL 3 3 UNINSTALL 5 4 BASIC OPERATION 7 4.1 Log In 7 4.2 Screen Layout 8

More information

Ishida Label Editor USER GUIDE

Ishida Label Editor USER GUIDE Ishida Label Editor USER GUIDE ISHIDA CO., LTD Copyright 2000 Ishida Co. Ltd., Japan Copyright 2000 Interface Translation Ltd., New Zealand No part of this manual may be reproduced or transmitted in any

More information

PC Software R&S FS300-K1

PC Software R&S FS300-K1 Copyright 0 Copyright Copyright Licence Agreement Rohde & Schwarz grants you the right to install the R&S FS300-K1 software package on one or more PCs of your choice. The licence included in the software

More information

PSM Comm2 Data Logging Software User Manual

PSM Comm2 Data Logging Software User Manual PSM Comm2 Data Logging Software User Manual Manual constructed using Software version v1_1c Revision 1.1 25 th Sept 2018 ABOUT THIS MANUAL PSMComm2 is a self-contained executable software program for use

More information

Exhibitor Software User s Manual. Exhibitor Software V

Exhibitor Software User s Manual. Exhibitor Software V Exhibitor Software User s Manual Exhibitor Software V1.0.1 090908 1 Contents 1. Exhibitor Software 2. Installation 3. Using Exhibitor Program 3.1 Starting the Program 3.2 Logging in to the Program 3.3

More information

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA4G1 TSA6G1 TSA8G1 TSA12G5

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA4G1 TSA6G1 TSA8G1 TSA12G5 USB Mini Spectrum Analyzer User Manual PC program TSA For TSA4G1 TSA6G1 TSA8G1 TSA12G5 Triarchy Technologies, Corp. Page 1 of 17 USB Mini Spectrum Analyzer User Manual Copyright Notice Copyright 2013 Triarchy

More information

Release Notes. R&S ES-SCAN EMI Measurement Software

Release Notes. R&S ES-SCAN EMI Measurement Software Release Notes Revision: 09 R&S ES-SCAN EMI Measurement Software Software Release V2.70 These Release Notes describe the following types and options of the R&S ES-SCAN EMI Measurement Software. R&S ES-SCAN,

More information

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command OPERATION MANUAL MV-410HS Layout Editor Version 3.0 - higher Command Command Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410HS

More information

GET TO KNOW FLEXPRO IN ONLY 15 MINUTES

GET TO KNOW FLEXPRO IN ONLY 15 MINUTES GET TO KNOW FLEXPRO IN ONLY 15 MINUTES Data Analysis and Presentation Software GET TO KNOW FLEXPRO IN ONLY 15 MINUTES This tutorial provides you with a brief overview of the structure of FlexPro and the

More information

Viewer 3.0. Operation Guide

Viewer 3.0. Operation Guide Viewer 3.0 en Operation Guide Viewer 3.0 Table of Contents en 3 Table of Contents 1 Introduction 5 1.1 About this Manual 5 1.2 Conventions in this Manual 5 1.3 Viewer 5 1.4 System Requirements 6 1.5 Additional

More information

IML-RESI F-Series. Electronic. F-Tools F-Tools Pro. Manual. Issued

IML-RESI F-Series. Electronic. F-Tools F-Tools Pro. Manual. Issued IML-RESI F-Series Electronic F-Tools F-Tools Pro Manual Issued 09-2008 IML Instrumenta Mechanik Labor System GmbH Großer Stadtacker 2 69168 Wiesloch Germany IML-RESI F-Series i The information contained

More information

Windows Me Navigating

Windows Me Navigating LAB PROCEDURE 11 Windows Me Navigating OBJECTIVES 1. Explore the Start menu. 2. Start an application. 3. Multi-task between applications. 4. Moving folders and files around. 5. Use Control Panel settings.

More information

Galaxie Report Editor

Galaxie Report Editor Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Galaxie Report Editor User s Guide Varian, Inc. 2008 Printed in U.S.A. 03-914949-00: Rev 6 Galaxie Report Editor i Table of Contents Introduction...

More information

HeadMouse. Robotic Research Team. University of Lleida

HeadMouse. Robotic Research Team. University of Lleida HeadMouse Robotic Research Team University of Lleida User Manual and Frequently Asked Questions What is HeadMouse? HeadMouse is a free program designed to replace the computer mouse. The user can control

More information

Instruction Manual. Version 2.0 dated Zehntner mapping and data analysis software. MappingTools. as from software version 1.

Instruction Manual. Version 2.0 dated Zehntner mapping and data analysis software. MappingTools. as from software version 1. Zehntner GmbH Testing Instruments Gewerbestrasse 4 CH-4450 Sissach Switzerland Tel +41 (0)61 953 05 50 Fax +41 (0)61 953 05 51 zehntner@zehntner.com www.zehntner.com Instruction Manual Version 2.0 dated

More information

Instruction manual. testo easyemission Software

Instruction manual. testo easyemission Software Instruction manual testo easyemission Software en 2 General Information General Information This documentation includes important information about the features and application of the product. Please read

More information

GV 2 Devicemanagement 2

GV 2 Devicemanagement 2 GV 2 Devicemanagement 2 getting started & usage 1/13 Index 1 General Remarks...3 2 Software...3 2.1 System Requirements...3 2.2 Installation...4 2.3 Un-Installation...5 3 User Interface...5 3.1 Menu Bar...6

More information

Plotting. Documentation. DDBSP - Dortmund Data Bank Software Package

Plotting. Documentation. DDBSP - Dortmund Data Bank Software Package Plotting Documentation DDBSP - Dortmund Data Bank Software Package DDBST Software & Separation Technology GmbH Marie-Curie-Straße 10 D-26129 Oldenburg Tel.: +49 441 361819 0 Fax: +49 441 361819 10 E-Mail:

More information

CECOS University Department of Electrical Engineering. Wave Propagation and Antennas LAB # 1

CECOS University Department of Electrical Engineering. Wave Propagation and Antennas LAB # 1 CECOS University Department of Electrical Engineering Wave Propagation and Antennas LAB # 1 Introduction to HFSS 3D Modeling, Properties, Commands & Attributes Lab Instructor: Amjad Iqbal 1. What is HFSS?

More information

Spectrometer Visible Light Spectrometer V4.4

Spectrometer Visible Light Spectrometer V4.4 Visible Light Spectrometer V4.4 Table of Contents Package Contents...3 Trademarks...4 Manual Driver and Application installation...5 Manual Application Installation...6 First Start of the Application...8

More information

DAT38MK2 Version 1.12

DAT38MK2 Version 1.12 COMPUTER PROGRAM MANUAL (SURVEY DATA REDUCTION MANUAL) DAT38MK2 Version 1.12 June, 2011 Geonics Limited 1745 Meyerside Drive, Mississauga, Ontario, Canada L5T 1C6 Tel: (905) 670 9580 Fax: (905) 670 9204

More information

SoftWare. M.Wave Professional PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

SoftWare. M.Wave Professional PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Operation Manual SoftWare M.Wave Professional PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.011.14 Contents 1.

More information

Beyond 20/20. Browser - English. Version 7.0, SP3

Beyond 20/20. Browser - English. Version 7.0, SP3 Beyond 20/20 Browser - English Version 7.0, SP3 Notice of Copyright Beyond 20/20 Desktop Browser Version 7.0, SP3 Copyright 1992-2006 Beyond 20/20 Inc. All rights reserved. This document forms part of

More information

SICAT SUITE VERSION 1.0. Instructions for use SIDEXIS XG English

SICAT SUITE VERSION 1.0. Instructions for use SIDEXIS XG English SICAT SUITE VERSION 1.0 Instructions for use SIDEXIS XG English Table of contents Table of contents 1 System requirements... 3 2 Overview of SICAT Suite... 5 3 Differences between full featured mode and

More information

Operating Manual. Version 7.3.4

Operating Manual. Version 7.3.4 Operating Manual Version 7.3.4 March 2011 Index Page 1. Installation instructions 4 1.1 System requirements 4 1.2 Installation procedure 4 1.3 Meitav-tec USB adaptor installation 7 2. Open Maxinet and

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide This manual is the operation guide for Medal Editor. Please refer to this manual to install the software or create medal data used on the processing machine. Items That May

More information

Software for the processing of measuring data from Hydrotechnik measuring instruments and systems

Software for the processing of measuring data from Hydrotechnik measuring instruments and systems Software for the processing of measuring data from Hydrotechnik measuring instruments and systems Software Manual Revision 1.3EN Software version 6.2 TKZ L8874-19-01.01EN Hydrotechnik GmbH All rights reserved

More information

Operation Manual. Light Pen II. [Windows / Mac OS] ENGLISH

Operation Manual. Light Pen II. [Windows / Mac OS] ENGLISH Operation Manual Light Pen II [Windows / Mac OS] ENGLISH Contents Contents 2 How to use the pointer and pen 3 Use with Windows 5 System requirements 5 Install the LightPenII software (Windows XP procedures)

More information

PSA-Manager Version 3 User Manual

PSA-Manager Version 3 User Manual PSA-Manager Version 3 User Manual CONTENTS 1 Introduction...2 2 File Types and Locations...3 3 PSA-Manager Windows...4 4 Viewing Trace Files...7 4.1.1 The Trace Memo sub-window...8 4.1.2 Printing Trace

More information

SI-100 Digital Microscope. User Manual

SI-100 Digital Microscope. User Manual SI-100 Digital Microscope User Manual Read this manual before use Keep for future reference Content 1 Introduction... 3 1.1 About The SI-100... 3 1.2 Advantage of SI-100... 3 1.3 Product Specification...

More information

Summit WMScanner 12.0 Quick Start Guide

Summit WMScanner 12.0 Quick Start Guide Summit WMScanner 12.0 Quick Start Guide Thank you choosing Summit WMScanner from Extreme Networks. Please read the Quick Start Guide installation/upgrade instructions prior to installing the software.

More information

2015 Gantner Instruments Inc.

2015 Gantner Instruments Inc. 1 Released: 3/2/15 2015 Gantner Instruments Inc. Operating instructions, manuals, and software are protected by copyright. Copying, duplicating, translating, conversion into any electronic medium or into

More information

User s Manual. CW500Viewer IM CW500-61EN. 2nd Edition

User s Manual. CW500Viewer IM CW500-61EN. 2nd Edition User s Manual CW500Viewer 2nd Edition Thank you for purchasing the CW500 Power Quality Analyzer. This manual explains the operating procedures of CW500Viewer, a software application included with the CW500.

More information

Operating Instructions

Operating Instructions Providing presentation solutions V iewer Software Program Operating Instructions NIPPON AVIONICS CO., LTD. 1 This manual describes the functions and operations for conducting presentations using ip Viewer.

More information

testo Comfort Software Professional 4 Instruction manual

testo Comfort Software Professional 4 Instruction manual testo Comfort Software Professional 4 Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 About this document... 5 3 Specifications... 6 3.1. Use... 6 3.2. System requirements... 6 4 First steps...

More information

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3 SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3 Thank you for purchasing TOA s Digital Speaker Processor. Please carefully follow the instructions in this manual to ensure long, trouble-free use

More information

D-Cut Master MANUAL NO. OPS639-UM-153 USER'S MANUAL

D-Cut Master MANUAL NO. OPS639-UM-153 USER'S MANUAL D-Cut Master MANUAL NO. OPS639-UM-153 USER'S MANUAL Software License Agreement Graphtec Corporation ( Graphtec ) grants the user permission to use the software (the software ) provided in accordance with

More information

Virtual MODELA USER'S MANUAL

Virtual MODELA USER'S MANUAL Virtual MODELA USER'S MANUAL Virtual MODELA is a program that simulates the movement of the tool on the screen. Contents Contents Part 1 Introduction 1-1 System Requirements... 4 1-2 Overview of Virtual

More information

ezimagex2 User s Guide Version 1.0

ezimagex2 User s Guide Version 1.0 ezimagex2 User s Guide Version 1.0 Copyright and Trademark Information The products described in this document are copyrighted works of AVEN, Inc. 2015 AVEN, Inc. 4595 Platt Rd Ann Arbor, MI 48108 All

More information

Sending image(s) to report Click Send Snapshot on any screen in Dolphin3D and choose the Send to Report option

Sending image(s) to report Click Send Snapshot on any screen in Dolphin3D and choose the Send to Report option Dolphin 3D Reports Sending image(s) to report Click Send Snapshot on any screen in Dolphin3D and choose the Send to Report option Creating a report step by step 1. Generate the desired images in Dolphin3D

More information

DriveWizard Plus Instruction Manual

DriveWizard Plus Instruction Manual DriveWizard Plus Instruction Manual To properly use the product, read this manual thoroughly. MANUAL NO. TOEP C730600 20C Table of Contents Safety Symbols and Markings...4 Manual Overview...5 Related Manuals...5

More information

VarioAnalyze. User Manual. JENOPTIK Group.

VarioAnalyze. User Manual. JENOPTIK Group. VarioAnalyze User Manual JENOPTIK Group. Dear User Dear User You should carefully read these instructions before you start operating the VarioAnalyze Software. Editorial deadline: October 2005 Document

More information

Version: 01P02B. U3 Map Maker Operational Guide

Version: 01P02B. U3 Map Maker Operational Guide Contents 1. Map Maker Software Overview... 4 1.1 Features... 4 1.2 Remarks... 4 1.3 Supported Devices... 4 2. Installing U3 Map Maker... 5 2.1 System Requirements... 5 2.2 Map Maker Installation... 5 3.

More information

DataMaster for Windows

DataMaster for Windows DataMaster for Windows Version 3.0 April 2004 Mid America Computer Corp. 111 Admiral Drive Blair, NE 68008-0700 (402) 426-6222 Copyright 2003-2004 Mid America Computer Corp. All rights reserved. Table

More information

Contents. Version 1.5 and later. Introduction Panel Descriptions Sending Still Images to the VR-4HD... 12

Contents. Version 1.5 and later. Introduction Panel Descriptions Sending Still Images to the VR-4HD... 12 VR-4HD RCS is software designed to control the VR-4HD remotely using a computer. By connecting the VR-4HD and a computer via USB, along with operating the unit from the computer, you can also save and

More information

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro CVI SPECTRAL PRODUCTS 111 Highland Drive Putnam CT, 06260 (860) 928-5834 SM32Pro 2.8.28 Table of Contents Warranty and Liability 1 Quick Start Installation Guide 2 System Requirements 3 Requirements for

More information

Edupen Pro User Manual

Edupen Pro User Manual Edupen Pro User Manual (software for interactive LCD/LED displays and monitors) Ver. 3 www.ahatouch.com Some services in Edupen Pro require dual touch capability. In order to use dual touch, your computer

More information

Table of Contents. Chapter 1 Introduction Features System Diagram... 2 Multi-Server... 2 Single-Server... 3

Table of Contents. Chapter 1 Introduction Features System Diagram... 2 Multi-Server... 2 Single-Server... 3 inex Standard Table of Contents Chapter 1 Introduction... 1 1.1 Features... 1 1.2 System Diagram... 2 Multi-Server... 2 Single-Server... 3 Chapter 2 Installation... 5 2.1 Product Information... 5 Package

More information

Smart KM Link User Manual

Smart KM Link User Manual Smart KM Link User Manual Table of Contents Table of Contents Overview...3 System Requirements...3 Features...3 Support Language...3 Getting Started...4 Changing the Settings...6 Keyboard & Mouse Control

More information

Introduction. Summary. Otasuke GP-EX! Introduction Summary. Intro-21. Development Environment Intro-4. Procedures of Creating New Screen

Introduction. Summary. Otasuke GP-EX! Introduction Summary. Intro-21. Development Environment Intro-4. Procedures of Creating New Screen Introduction Summary Summary Intro-1 Development Environment Intro-4 Procedures of Creating New Screen Intro-5 Main Window Intro-6 Tips for man-hours reduction ~Full use of Work Space~ Intro-10 Simulation

More information

Wavy for PLZ-4W Ver. 4.0

Wavy for PLZ-4W Ver. 4.0 Operation Manual Sequence Creation Software Wavy for PLZ-4W Ver. 4.0 Version 4.0 Prepared: June 21, 2006 KIKUSUI ELECTRONICS CORPORATION 1/35 Note Before contacting us to request repair, inspection, or

More information

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500 CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide CyberScan DO 1500 Bench Dissolved Oxygen Meter Technology Made Easy... 68X292341 Rev.0 01/04 PREFACE Thank you for selecting the CyberScan

More information

GlossTools. Instruction Manual ZGM 1110 ZGM 1120 ZGM 1130

GlossTools. Instruction Manual ZGM 1110 ZGM 1120 ZGM 1130 GlossTools Instruction Manual As from software version 1.0.0036 for the following glossmeter series: ZGM 1110 ZGM 1120 ZGM 1130 Index Exclusion of liability... 3 1 Safety information... 4 1.1 Symbols

More information

Installing the Software

Installing the Software Logic User s Guide Note: this is a new version to support the 1.1.0+ software. Please let us know if you can t find what you re looking for http://www.saleae.com/contact Contents Installing the Software...

More information

NiceForm User Guide. English Edition. Rev Euro Plus d.o.o. & Niceware International LLC All rights reserved.

NiceForm User Guide. English Edition. Rev Euro Plus d.o.o. & Niceware International LLC All rights reserved. www.nicelabel.com, info@nicelabel.com English Edition Rev-0910 2009 Euro Plus d.o.o. & Niceware International LLC All rights reserved. www.nicelabel.com Head Office Euro Plus d.o.o. Ulica Lojzeta Hrovata

More information

MESURgauge Software. User s Guide

MESURgauge Software. User s Guide MESURgauge Software User s Guide MESURgauge Software Thank you! Thank you for purchasing MESURgauge software, a data collection and analysis program developed to: Measure Collect data from digital force

More information

Table of Contents. Chapter 1 Introduction Features System Diagram... 2

Table of Contents. Chapter 1 Introduction Features System Diagram... 2 inex Standard Table of Contents Chapter 1 Introduction... 1 1.1 Features... 1 1.2 System Diagram... 2 Chapter 2 Installation... 5 2.1 Product Information... 5 Package Contents... 5 System Requirements...

More information

Tach Facts V3.0 Software

Tach Facts V3.0 Software Tach Facts V3.0 Software Download runs from your Auto Meter Playback Tach with Tach-Facts Software. Instr. No. 2650-978 Tach Facts provides complete race analysis on your personal computer. Introduction

More information

IDIS Solution Suite. Video Wall Service. Software Manual. Powered by

IDIS Solution Suite. Video Wall Service. Software Manual. Powered by Solution Suite Software Manual Video Wall Service Powered by Before reading this manual This Operation Manual provides instructions for using Solution Suite, a network integration solution enabling remote

More information

SUNLITE is a trademark of Bruno Nicolaudie. WINDOWS is a trademark of the MICROSOFT CORPORATION. All rights reserved. No parts of this work may be

SUNLITE is a trademark of Bruno Nicolaudie. WINDOWS is a trademark of the MICROSOFT CORPORATION. All rights reserved. No parts of this work may be SUNLITE is a trademark of Bruno Nicolaudie. WINDOWS is a trademark of the MICROSOFT CORPORATION. All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic,

More information

Solo 4.6 Release Notes

Solo 4.6 Release Notes June9, 2017 (Updated to include Solo 4.6.4 changes) Solo 4.6 Release Notes This release contains a number of new features, as well as enhancements to the user interface and overall performance. Together

More information

1 GB RAM USB port 1152x864 minimum screen resolution (1280x720 recommended) 15 GB of hard drive space for full install

1 GB RAM USB port 1152x864 minimum screen resolution (1280x720 recommended) 15 GB of hard drive space for full install System Requirements Windows Microsoft Windows XP, Vista, 7, 8 or 10 2.33GHz or faster x86-compatible processor or Intel Atom 1.6GHz or faster processor for netbooks Mac Mac OS X v10.6, v10.7, v10.8, v10.9

More information

testo easyheat Configuration and Analysis software Instruction manual

testo easyheat Configuration and Analysis software Instruction manual testo easyheat Configuration and Analysis software Instruction manual en 2 General Information General Information This documentation includes important information about the features and application of

More information

Quick Start Guide. v1.1. Copyright 2011 AVID Technologies, Inc. Twinsburg, Ohio USA All Rights Reserved

Quick Start Guide. v1.1. Copyright 2011 AVID Technologies, Inc. Twinsburg, Ohio USA All Rights Reserved Quick Start Guide v1.1 Copyright 2011 Twinsburg, Ohio USA All Rights Reserved Qi Sniffer Quick Start Guide v1.1 Page 2 Overview AVID Technologies Qi Sniffer is a diagnostic tool that can be used to passively

More information

Codesoft 6 Premier Overview Manual. Thermocode Series 2 (all Printers)

Codesoft 6 Premier Overview Manual. Thermocode Series 2 (all Printers) Thermocode Series 2 Codesoft Overview Manual. (Issue 4.1) 28 July 2003 Page No. - 1 - Open Date Equipment Ltd. Unit s 8 & 9 Puma Trade Park, 145 Morden Road, Mitcham, Surrey. CR4 4DG United Kingdom. Tel:-

More information

XC USB 2.0 Smart Transfer Cable

XC USB 2.0 Smart Transfer Cable XC-4949 USB 2.0 Smart Transfer Cable Table of Contents Overview... 3 System Requirements... 3 Features... 3 Support Language... 3 Getting Started... 4 Changing the Settings... 6 Keyboard & Mouse Control

More information

intelligent Touch Manager

intelligent Touch Manager Commissioning Manual Supplementary Volume intelligent Touch Manager Layout Screen Creation Tool Model DCM601A51 MONITOR SERVICE LAN LAN SW FRONT BACK ON SLAVE BACKUP D MASTER OFF MASTER CPU ALIVE LAN LINK

More information

BlueViewer Software Handbook

BlueViewer Software Handbook BlueViewer Software Handbook Part Number: 204022-00 Revised April 2011 BlueView Technologies, Inc. All rights reserved. All product names are trademarks of their respective companies. Table of Contents

More information

SlideReader V12. Software Manual. System Requirements. Required Privileges

SlideReader V12. Software Manual. System Requirements. Required Privileges SlideReader V12 Software Manual System Requirements - 1.8 GHz Processor or higher - Operating System: WIN XP professional or WIN 7 professional, 64-Bit - 1 Gb RAM or more - Minimum 2 Gb free disk space,

More information

HeadMouse. Robotic Research Team. University of Lleida

HeadMouse. Robotic Research Team. University of Lleida HeadMouse Robotic Research Team University of Lleida User Manual and Frequently Asked Questions What is HeadMouse? HeadMouse is a free program designed to replace the computer mouse. The user can control

More information

N2KExtractor. Maretron Data Extraction Software User s Manual

N2KExtractor. Maretron Data Extraction Software User s Manual N2KExtractor Maretron Data Extraction Software User s Manual Revision 3.1.6 Copyright 2017 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

Breeze User Guide. Breeze Multiple Stream Video Processors. Light and Standard Editions Version 5.3.2

Breeze User Guide. Breeze Multiple Stream Video Processors. Light and Standard Editions Version 5.3.2 Breeze User Guide Breeze Multiple Stream Video Processors Light and Standard Editions Version 5.3.2 Copyright 1989-2007 Discovery Scientific, LLC All rights reserved www.discoverybiz.net January 01, 2007

More information

SAS Visual Analytics 8.2: Working with Report Content

SAS Visual Analytics 8.2: Working with Report Content SAS Visual Analytics 8.2: Working with Report Content About Objects After selecting your data source and data items, add one or more objects to display the results. SAS Visual Analytics provides objects

More information

WorldTracker RF Real-Time Tracker

WorldTracker RF Real-Time Tracker WorldTracker RF Real-Time Tracker Long-Range Radio-Controlled Tracking Quick-Start User s Manual Security Concepts 110 Palm Ave Millbrae, California 650-692-8100 www.trackingtheworld.com WorldTracker RF

More information

ENVI Tutorial: Introduction to ENVI

ENVI Tutorial: Introduction to ENVI ENVI Tutorial: Introduction to ENVI Table of Contents OVERVIEW OF THIS TUTORIAL...1 GETTING STARTED WITH ENVI...1 Starting ENVI...1 Starting ENVI on Windows Machines...1 Starting ENVI in UNIX...1 Starting

More information

USER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A.

USER MANUAL S6000 / S7000 S8000 / S9000. Associated Research, Inc., West Laurel Drive Lake Forest, Illinois, U.S.A. USER MANUAL TM S6000 / S7000 S8000 / S9000 Associated Research, Inc., 2005 13860 West Laurel Drive Lake Forest, Illinois, 60045-4546 U.S.A. Item 38086 Ver 1.04 Printed Nov 15, 2005 TABLE OF CONTENTS INSTALLATION

More information

testo Comfort Software Professional 4

testo Comfort Software Professional 4 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo Comfort Software Professional 4 Instruction manual 1 Contents 1 Contents

More information

WaveVision 5 Software

WaveVision 5 Software WaveVision 5 Software Data Acquisition and Analysis Tool User s Guide October 2008 Table of Contents 1.0 The WaveVision 5 System 3 2.0 Overview.. 4 2.1 Features and Capabilities of WaveVision 5 Software

More information