WEB CONTROL PRODUCTS. User Manual. RSTC1000 HMI/PLC Design Guide FORM NO. L C-0908

Size: px
Start display at page:

Download "WEB CONTROL PRODUCTS. User Manual. RSTC1000 HMI/PLC Design Guide FORM NO. L C-0908"

Transcription

1 WEB CONTROL PRODUCTS User Manual RSTC1000 HMI/PLC Design Guide

2 DANGER Read this manual carefully before installation and operation. Follow Nexen s instructions and integrate this unit into your system with care. This unit should be installed, operated and maintained by qualified personnel ONLY. Improper installation can damage your system or cause injury or death. Comply with all applicable codes. In accordance with Nexen s established policy of constant product improvement, the specifi cations contained in this manual are subject to change without notice. Technical data listed in this manual are based on the latest information available at the time of printing and are also subject to change without notice. Technical Support: Nexen Group, Inc. 560 Oak Grove Parkway Vadnais Heights, MN i ISO 9001 Certifi ed Copyright 2008 Nexen Group, Inc.

3 TABLE OF CONTENTS Modbus RS485 Communications Connection Diagrams RSTC1000 Modbus Table of Registers RSTC1000 Modbus Registers Product Information Modbus Communication Parameters Diagnostics Tuning Setup Display Control Signal Selection Diameter Calibration Tension Calibration Warranty ii

4 MODBUS RS485 COMMUNICATIONS NOTE: This manual assumes familiarity with the Modbus RTU over Serial Line protocol. If you are not familiar with this protocol, then the following documents must be read: Modbus Application Protocol Specification and Modbus over Serial Line Specification & Implementation Guide found at modbus.org. Modbus RTU is a master/slave protocol that allows the RSTC1000 to send information only after it has been requested from the master device, typically the RSTC Operator Panel (ROP), Programmable Logic Controller (PLC), or Human Machine Interface (HMI). There can be up to 247 devices on one network all communicating with just one master. Each device on the network must share the same communication settings and have a unique address in the range of 1 to 247 with the exception of the master, which does not require an address. The RSTC1000 Modbus RTU communication settings are as follows: Settings Options Default Network Address Range 1 to Baud Rates 4800, 9600, 14400, 19200, 38400, Parity none, odd, even None Stop Bits 1 (odd or even parity), 2 (no parity) 2 These settings can be changed via the RSTC Communications Software, or must fi rst be used by the master to establish communication with the RSTC1000 and then changed as desired. The ROP has been programmed with the same communication parameters and will, upon connecting to the RSTC1000, be able to communicate without any changes. Because the ROP is a master device there can be no other masters on the same Modbus network. Any address in the range of 1 to 247 can be assigned to the RSTC1000. Baud rates, which designate the message transmission speed in units of bits per second, can be set for 4800, 9600, 14400, 19200, 38400, or The larger the baud rate the less time it takes for a message to travel across the network and the less time a device spends sending or receiving the message. However, the trade off is typically reduced communication cable length. The Modbus standard specifi es the maximum communication cable length as 1000 meters using a 4-wire implementation (500 meters for a 2-wire implementation), 26 AWG or larger wire, shielded, at 9600 baud. Cable capacitance and wire resistance affect baud rates, and as cable lengths increase so does the capacitance and resistance. This can cause a reduction in the speed that a message can travel across the network. Each message byte that is sent using the Modbus RTU protocol is eleven bits long with the message data byte being eight bits and then encapsulated by three other bits: start, parity, and stop. The start bit marks the beginning of the message byte. Parity is used for error detection and is often not necessary as another error detection method, Cyclical Redundancy Checking (CRC), is also performed on the message byte to check for errors. The stop bit marks the end of the message byte. Parity can be set for none, odd, or even. Stop Bits must be set to 1 for use with odd or even parity or 2 for use with no parity. Load Termination Resistors (LTR) are necessary to reduce noise and are applied to the devices at the remote ends of the network. These resistors can be installed at the RSTC1000 s Modbus RS485 port connector (refer to Figure 1). Typical values for LTRs are 150 ohms and 0.5 watts. 1

5 CONNECTION DIAGRAMS Modbus RS485 Port: This port is for communicating with the RSTC1000 using the Modbus RTU protocol over a 2-wire or 4-wire RS485 physical layer (Refer to Figure 1). Communication Indicator: Yellow indicator, visible through top cover, will illuminate whenever the RSTC1000 communicates over the RS485 port. ROP Red Black White (RxB+) ROP - RSTC RSTC VDC 2 DC Common 3 TxB+ Communication Error Indicator: Red indicator, visible through top cover, will illuminate whenever the RSTC1000 detects an error with a received message. Yellow (RxA ) Blue (TxB+) Orange (TxA ) TxA RxB+ RxA Power Indicator Reset Communication Indicator Communication Error Indicator RSTC1000 USB Cable Recommendation: - Shielded - 24 awg is always sufficient - 4 wire system, 1000 m (9600 baud) - 2 wire system, 500 m (9600 baud) Termination resistors added externally - Recommend 150 Ω, 0.5 W LTR = User supplied line termination resistor RS485 Figure 2 RSTC1000 Two Wire RS485 Connections RSTC1000 PLC or HMI DC Common Non-Inverted Tx/Rx DC Common TxB+ LTR 4 5 TxA RxB+ Inverted Tx / Rx 6 RxA Four Wire RS485 Connections RSTC1000 PLC or HMI 1 DC Common 2 DC Common RxB+ RxA LTR 3 4 TxB+ TxA TxB+ TxA LTR 5 6 RxB+ RxA Figure 1 Modbus RS485 Connections 2

6 RSTC1000 MODBUS TABLE OF REGISTERS Register Name Type Page Register Name Type Page Product Information Setup 1-4 Product Name Read Only 4 63 Torque Actuator Read/Write Product Number Read Only 4 64 Torque Actuator Inertia Read/Write Serial Number Read Only 4 65 Tension Zone Selection Read/Write Software Part Number Read Only 4 66 Minimum Output Read/Write 8 12 Software Revision Read Only 4 67 Maximum Output Read/Write 8 Modbus Comm Setup 68 Standby Output Read/Write 8 15 Baud Rate Read/Write 5 69 Web Material Selection Read/Write 8 16 Modbus Device Address Read/Write 5 70 Average Web Width Read/Write 9 17 Parity Read/Write 5 71 Maximum Roll Diameter Read/Write 9 18 Stop Bits Read/Write 5 72 Minimum Core Roll Diameter Read/Write 9 19 Remote Communications Reset Write Only 5 Display Diagnostics 78 Display Units Read/Write 9 30 Alarm Status Read Only 5 79 Language Read/Write Load Cell 1 Tension Read Only 5 Control Load Cell 2 Tension Read Only 5 80 Panel Write Enable Read/Write 9 35 Control Output Read Only 6 81 Manual/Automatic Mode Read/Write Roll Diameter Read Only 6 82 Manual Output Level Read/Write 9 38 Run/Stop Read/Write 6 83 Alarm Acknowledge Write Only Splice A Read/Write 6 84 Output On/Off Read/Write Splice B Read/Write 6 Signal Selection 41 Adaptation Read Only 6 85 Run/Stop Signal Read/Write Taper Tension Setpoint Read Only 6 Diameter Sensor Calibration Tuning 87 Diameter Sensor Installed Write Only Taper Tension Enable Read/Write 6 88 Diameter-Core Size Read/Write Tension Setpoint Read/Write 7 89 Diameter-Large Roll Size Read/Write Taper Read/Write 7 90 Diameter Measure Flag Read/Write Taper Delay Read/Write 7 Tension Calibration 51 Gain Read/Write Minimum Tension Setpoint Read/Write Stabilization Read/Write Maximum Tension Setpoint Read/Write Initial Adaptation Read/Write 7 77 Tension Calibration Set Read/Write Splice Adaptation Read/Write 7 93 Load Cell Measure Flag Read/Write Adaptation Rate Read/Write Tare Tension-Calibration Set 1 Read/Write Remote Tension Setpoint Enable Read/Write Span Tension-Calibration Set 1 Read/Write 12 Setup Tare Tension-Calibration Set 2 Read/Write Tension Monitor Enable Read/Write Span Tension-Calibration Set 2 Read/Write Tension Alarm Tolerance Read/Write Tare Tension-Calibration Set 3 Read/Write Alarm Output Type Read/Write Span Tension-Calibration Set 3 Read/Write 13 3

7 RSTC1000 MODBUS REGISTERS All values written to or read from the RSTC1000 must be in Imperial units. Conversion of values from other units of measure are done within the HMI or PLC. The following Modbus registers are numbered per the Modbus standard. Many PLCs use an alternate numbering scheme and the Modbus register numbers can be converted to the PLC numbering scheme by adding 40,001 to each Modbus register number. Common Defi nitions and Abbreviations: lsb: least signifi cant byte msb: most signifi cant byte lsw: least signifi cant word msw: most signifi cant word byte: 8 bits, range word: 2 bytes, range PRODUCT INFORMATION 1 4: Product Name Sent as ASCII values, read only. Example: RSTC1000 Register 1: R (msb), S (lsb) Register 2: T (msb), C (lsb) Register 3: 1 (msb), 0 (lsb) Register 4: 0 (msb), 0 (lsb) 6 7: Product Number Sent as long integer, read only. Example: Register 6: 14 (msw) Register 7: (lsw) = (14 * 65536) : Serial Number Sent as long integer, read only. Example: Register 8: 18 (msw) Register 9: (lsw) = (18 * 65536) : Software Part Number Sent as long integer, read only. Example: Register 10: 0 (msw) Register 11: (lsw) = (0 * 65536) : Software Revision Sent as ASCII value, read only. Example: A Register 12: 0 (msb), 65 (lsb) 4

8 MODBUS COMMUNICATION PARAMETERS Writing to registers changes the communication parameters. New paramter values take effect immediately after writing to register 19, or after turning the RSTC1000 power off and back on. 15: Baud Rate Sent as integer, read & write. Supported baud rates are 4800, 9600, 14400, 19200, 38400, 56000). Example: Register 15: 75 (msb), 0 (lsb) = (75 * 256) : Device Address Sent as integer, read & write. Address values are Example: 24 Register 16: 0 (msb), 24 (lsb) 17: Parity Sent as integer, read & write. Parity values are 1 = even, 2 = odd, 3 = none. Example: 3 Register 17: 0 (msb), 3 (lsb) 18: Stop Bits Sent as integer, read & write. Stop Bit values are 1 = 1 stop bit, 2 = 2 stop bits. Example: 2 Register 18: 0 (msb), 2 (lsb) 19: Remote Communications Reset Sent as integer, write only. Writing a 1 will cause RSTC1000 to begin using updated communication parameters immediately. Reading this variable will return a zero. Example: 1 Register 19: 0 (msb), 1 (lsb) DIAGNOSTICS 30: Alarm Status Sent as integer, read only. Web Break: value = 128, total loss of web tension. No Control: value = 72, control signal output has reached 0% or 100% during automatic operation and web tension is not at set point. High Tension: value = 64, web tension is greater than the high-tension limit. Low Tension: value = 32, web tension is less than the low-tension limit. Max Output: value = 16, control signal output has reached maximum output limit, typically 100%. Min Output: value = 8, control signal output has reached minimum output limit, typically 0%. Example: 32 Register 30: 0 (msb), 32 (lsb) 31-32: Load Cell 1 Tension Floating point number sent as long integer * 1000 in units of lbs, read only, tension range is to 10, lbs. Example: lbs Register 31: 8 (msw) Register 32: (lsw) Load Cell 1 Tension = ((8 * 65536) ) / 1000 = lbs 33-34: Load Cell 2 Tension Floating point number sent as long integer * 1000 in units of lbs, read only, tension range is to 10, lbs. Example: lbs Register 33: 8 (msw) Register 34: (lsw) Load Cell 2 Tension = ((8 * 65536) ) / 1000 = lbs 5

9 35: Control Output % Floating point sent as integer * 10, read only. Control Output % range is 0.0 to Example: 45.6% Register 35: 1 (msb), 200 (lsb) Control Output = ((1 * 256) + 200) / 10) = 45.6% 36 37: Roll Diameter Floating point number sent as long integer * 1000 in units of inches, read only, diameter range is to Example: inches Register 36: 0 (msw) Register 37: (lsw) Roll Diameter = ((0 * 65536) ) / 1000 = inches 38: Run/Stop Sent as integer, read & write. Run/Stop values are 1 = run and 0 = stop. Writing a 1 to the RSTC1000 will place it in the run mode and writing a 0 will place it in the stop mode. Reading this register provides the RSTC1000 s current operating mode. Example: 1 Register 38: 0 (msb), 1 (lsb) 39: Splice A Sent as integer, read & write. Write 1 to make Control Output A the controlling output and Control Output B the standby output. Register 39 can be read immediately after initially writing 1 and the returned value will be 1 for approximately one second before returning to zero. Example: 1 Register 39: 0 (msb), 1 (lsb) 40: Splice B Sent as integer, read & write. Write 1 to make Control Output B the controlling output and Control Output A the standby output. Register 40 can be read immediately after initially writing 1 and the returned value will be 1 for approximately one second before returning to zero. Example: 1 Register 40: 0 (msb), 1 (lsb) 41: Adaptation Floating point number sent as integer * 10, read only. Read the current calculated adaptation value. Used for diagnostic work. Adaptation ranges from 0.0 to Example: 8.9 Register 41: 0 (msb), 89 (lsb) Adaptation = ((0 * 256) + 89) / 10 = : Taper Tension Setpoint Floating point number sent as long integer * 1000 in units of lbs, read only, range is to 10, lbs but restricted by Maximum and Minimum Tension Setpoint values. Reads the calculated taper tension setpoint which decreases as roll diameter increases, calculation is always performed regardless of Taper Tension Enable. Taper Tension Setpoint is a function of Taper Factor and a condition of Taper Delay. Example: lbs Register 43: 8 (msw) Register 44: (lsw) Taper Tension Setpoint = ((8 * 65536) ) / 1000 = lbs TUNING 45: Taper Tension Enable Sent as integer, read & write. Taper Tension Enable has values of 0 for off and 1 for on. When set to 1, web tension will decrease with increasing roll diameter as a function of Taper Factor and a condition of Taper Delay, when set to 0, web tension remains at Tension Setpoint value. Example: 1 Register 45: 0 (msb), 1 (lsb) 6

10 46 47: Tension Setpoint Floating point number sent as long integer * 1000 in units of lbs, read & write, range is to 10, lbs but restricted by Maximum and Minimum Tension Setpoint values. Read the current tension setpoint or write a new tension setpoint value. Example: lbs Register 46: 8 (msw) Register 47: (lsw) Tension Setpoint = ((8 * 65536) ) / 1000 = lbs 48: Taper Sent as integer, read & write. Taper Factor has a range of 0 to 100. Taper Factor controls how much the tension setpoint is decreased for an increase in roll diameter. Larger values of Taper Factor will increase the rate of decrease and smaller values will decrease the rate of decrease. A value of 0 will result in no tension setpoint decrease. Example: 37 Register 48: 0 (msb), 37 (lsb) 49-50: Taper Delay Floating point number sent as long integer * 1000 in units of inches, read & write, range of to This value specifi es the roll diameter at which tension tapering is to begin. Example: inches Register 49: 0 (msw) Register 50: (lsw) Taper Delay = ((0 * 65536) ) / 1000 = inches 51: Gain Floating point number sent as integer * 10, read & write. Gain has a range of Example: 8.9 Register 51: 0 (msb), 89 (lsb) Gain = ((0 * 256) + 89) / 10 = : Stabilization Floating point number sent as integer * 10, read & write. Stabilization has a range of Example: 5.3 Register 52: 0 (msb), 53 (lsb) Stabilization = ((0 * 256) + 53) / 10 = : Initial Adaptation Floating point number sent as integer * 10, read & write. Initial Adaptation has a range of Example: 11.4 Register 53: 0 (msb), 114 (lsb) Initial Adaptation = ((0 * 256) + 114) / 10 = : Splice Adaptation Floating point number sent as integer * 10, read & write. Splice Adaptation has a range of Example: 11.4 Register 54: 0 (msb), 114 (lsb) Splice Adaptation = ((0 * 256) + 114) / 10 = : Adaptation Rate Floating point number sent as integer * 10, read & write. Adaptation Rate has a range of Example: 11.4 Register 55: 0 (msb), 114 (lsb) Adaptation Rate = ((0 * 256) + 114) / 10 = : Remote Tension Setpoint Enable Sent as integer, read & write. Remote Tension Setpoint Enable has values of 0 for Off and 1 for On. Set to 1 for the Tension Setpoint value to be read from the Remote Tension Setpoint analog input. Set to 0 for the Tension Setpoint value to be sent over the Modbus network. Example: 1 Register 60: 0 (msb), 1 (lsb) 7

11 SETUP 60: Tension Monitor Enable Sent as integer, read & write. Tension Output Enable has values of 0 for Off and 1 for On. Set to 1 for actual tension to be available on Control Output B. Set to 0 for the controlling or standby outputs to be available on Control Output B. Splice B register command and hardware input is ignored when Tension Output Enable is set to 1. Example: 1 Register 56: 0 (msb), 1 (lsb) 61: Tension Alarm Tolerance Sent as integer, read & write. Tension Alarm Tolerance has a range of 0 100%. Example: 25% Register 61: 0 (msb), 25 (lsb) Tension Alarm Tolerance = (0 * 256) + 25 = 25% 62: Alarm Output Type Sent as integer, read & write. Alarm Output Type has values of 0 for Normally Open and 1 for Normally Closed. Example: 1 Register 62: 0 (msb), 1 (lsb) 63: Torque Actuator Sent as integer, read & write. Torque Actuator has the following values: 1 Pneumatic Brake 2 Pneumatic Clutch 3 Magnetic Particle Brake 4 Magnetic Particle Clutch 5 Electric Brake 6 Electric Clutch 7 Motor-Drive System Example 2 Pneumatic Clutch Register 63: 0 (msb), 2 (lsb) 64: Torque Actuator Inertia Sent as integer * 100 in units of lb-ft 2, read & write. Torque Actuator Inertia has a range of 0.00 to Example lb-ft 2 Register 64: 8 (msb), 89 (lsb) Torque Actuator Inertia = ((8 * 256) + 89) / 100 = lb-ft2 65: Tension Zone Selection Sent as integer, read & write. Tension Zone Selection has values of 1 for Unwind and 2 for Wind. Example 2 Pneumatic Clutch Register 65: 0 (msb), 2 (lsb) 66: Minimum Output % Sent as intger, read & write. Minimum Output has a range of %. Example 32% Register 66: 0 (msb), 32 (lsb) 67: Maximum Output % Sent as intger, read & write. Maximum Output has a range of %. Example 10% Register 67: 0 (msb), 10 (lsb) 68: Standby Output % Sent as intger, read & write. Standby Output has a range of %. Example 67% Register 68: 0 (msb), 67 (lsb) 69: Web Material Selection Sent as integer, read & write. Web Material Selection has values of 1 for paper and plastic, 2 for aluminum, and 3 for steel. Example 2 aluminum Register 69: 0 (msb), 2 (lsb) 8

12 70: Average Web Width Floating point number sent as integer * 10 in units of inches, read & write. Average Web Width has a range of inches. Example inches Register 70: 11 (msb), 56 (lsb) Average Web Width = ((11 * 256) + 56) / 10 = inches 71: Maximum Roll Diameter Floating point number sent as integer * 10 in units of inches, read & write. Large Roll Diameter has a range of inches. Example 40.5 inches Register 71: 1 (msb), 149 (lsb) Average Web Width = ((1 * 256) + 149) / 10 = 40.5 inches 72: Minimum Core Roll Diameter Floating point number sent as integer * 10 in units of inches, read & write. Core Roll Diameter has a range of inches. Example 3.5 inches Register 71: 0 (msb), 35 (lsb) Average Web Width = ((0 * 256) + 35) / 10 = 3.5 inches DISPLAY 78: Display Units Sent as integer, read & write. Display Units has values of 0 for Imperial (English) and 1 for Metric. Display Units has no effect on the RSTC as it only stores the value, and register values are communicated in Imperial units only. Any Imperial to Metric or Metric to Imperial conversion is done in the HMI or PLC. Example 1 Metric Register 77: 0 (msb), 1 (lsb) 79: Language Sent as integer, read & write. Language has values of 0 for English, 1 for Spanish, 2 for French, 3 for German, and 4 for Italian. Language is used primarily to select the language in which the RSTC Operator Panel displays text and has no effect on the RSTC. Example 0 English Register 78: 0 (msb), 0 (lsb) CONTROL 80: Panel Write Enable Sent as integer, read & write. Panel Write Enable has values of 0 for disable and 1 for enable. RSTC1000 sets this register to 0 whenever the RSTC Communications Software is connected to the RSTC1000. An HMI can read this register and when equal to 0, any values sent by the HMI will be ignored by the RSTC1000. After the RSTC Communications Software is disconnected, the RSTC1000 sets this register to 1 and the HMI can again send values to the RSTC1000. This handshaking can be used to prevent two devices from sending register value changes to the RSTC1000 at the same time. Example 1 Enable Register 79: 0 (msb), 1 (lsb) 81: Manual/Automatic Mode Sent as integer, read & write. Manual/Automatic Mode has a value of 0 for Manual and 1 for Automatic. When mode is set to Manual the RSTC1000 control output can be controlled using the Manual Output Level register. When mode is set to Automatic the RSTC1000 control output is automatically controlled and writing to Manual Output Level has no effect. Example 1 Automatic Register 81: 0 (msb), 1 (lsb) 82: Manual Output Level % Sent as integer, read & write. Manual Output Level has a range of 0 to 100%. When the RSTC1000 is in manual mode, writing to this register will immediately change the Control Output s signal level. Example 67% Register 82: 0 (msb), 67 (lsb) 9

13 83: Alarm Acknowledge Sent as integer, write only. Alarm Acknowledge has a value of 1 to acknowledge an alarm. Writing a 1 to this register will turn off all alarm outputs until the alarm condition is satisfi ed and occurs again. Example 1 Register 83: 0 (msb), 1 (lsb) 84: Output On/Off Sent as integer, read & write. Output On/Off has a value of 0 for Off and 1 for On. Writing to this register will affect both RSTC1000 control outputs. Example 0 Output Off Register 84: 0 (msb), 0 (lsb) SIGNAL SELECTION 85: Run/Stop Signal Selection Sent as integer, read & write. Run/Stop Signal Selection has the following values: 1 run/stop maintained 2 run/stop momentary 3 run only momentary 4 run pulsed (encoder) 5 run/stop signal via Modbus Communications Example 4 run pulsed (encoder) Register 85: 0 (msb), 4 (lsb) DIAMETER CALIBRATION When calibrating the roll diameter signal, send registers 87 through 90 in the order shown here. 87: Diameter Sensor Installed Sent as integer, write only. Diameter Sensor Installed has a value of 0 for no sensor installed and 1 for sensor installed. When Diameter Sensor Installed is set to 0, values for registers 89 and 90 are ignored and Roll Diameter register is always 0. Example 1 Register 87: 0 (msb), 1 (lsb) 88: Diameter Core Size Floating point value sent as integer *10 in units of inches, read & write. Core Size is the outside diameter of roll s core or any roll diameter that is smaller than the roll diameter used for Large Roll Size. It has a range of 0.0 to 50.0 inches Example 3.5 inches Register 88: 0 (msb), 35 (lsb) Core Size = ((0 * 256) + 35) / 10 = 3.5 inches 89: Diameter Large Roll Size Floating point value sent as integer *10 in units of inches, read & write. Large Roll Size is the outside diameter of any roll used for diameter calibration that is larger than the diameter used for Core Size. It has a range of 0.0 to inches Example 42.7 inches Register 89: 1 (msb), 171(lsb) Large Roll Size = ((1 * 256) + 171) / 10 = 42.7 inches 10

14 90: Diameter Measure Flag Sent as integer, read & write. Diameter Measure Flag is only to be used after registers 87, 88, and 89 have been written. 1. Apply the voltage representing the Core Size to the Diameter Sensor Input terminal and then write a 1 to Diameter Measure Flag register. RSTC1000 will measure this voltage and calibrate the smaller roll size. 2. Read Diameter Measure Flag to determine when previous calibration step is complete. Calibration step is complete when fl ag = Apply the voltage representing the Large Roll Size to the Diameter Sensor Input terminal and then write a 2 to Diameter Measure Flag register. RSTC1000 will measure this voltage and calibrate the larger roll size. 4. Read Diameter Measure Flag to determine when previous calibration step is complete. Calibration step is complete when fl ag = 0. The diameter measurement is now calibrated and ready for use. TENSION CALIBRATION Set the Maximum Tension Setpoint before calibrating the tension sensors. Afterwards, re-calibration of tension sensors is necessary whenever Maximum Tension Setpoint is changed : Minimum Tension Setpoint Floating point number sent as long integer * 1000 in units of lbs, read & write, range is to 10, lbs. Minimum Tension Setpoint value must be less than Maximum Tension Setpoint value. Read the current minimum tension setpoint or write a new minimum tension setpoint value. Example: lbs Register 73: 0 (msw) Register 74: (lsw) Tension Setpoint = ((0 * 65536) ) / 1000 = lbs 75 76: Maximum Tension Setpoint Floating point number sent as long integer * 1000 in units of lbs, read & write, range is to 10, lbs. Maximum Tension Setpoint value must be greater than Minimum Tension Setpoint value. Read the current maximum tension setpoint or write a new maximum tension setpoint value. Example: lbs Register 75: 4 (msw) Register 76: (lsw) Tension Setpoint = ((4 * 65536) ) / 1000 = lbs 77: Tension Calibration Set Sent as integer, read & write. Tension Calibration Set has values of 1 for Calibration Set 1, 2 for Calibration Set 2, and 3 for Calibration Set 3. Writing a value to this register selects the desired calibration set. Example 3 Tension Calibration Set 3 Register 80: 0 (msb), 3 (lsb) 11

15 When calibrating the tension sensor signal, the registers for each calibration set must be written in the order shown here. Calibration Set : Tare Tension Floating point number sent as long integer * 1000 in units of lbs, read & write. Tare Tension is typically set to 0 and represents the web tension at the tare condition when the load cells measure only the weight of the tension sensing roller and its associated hardware. Example: lbs Register 94: 4 (msw) Register 95: (lsw) Tare Tension = ((4 * 65536) ) / 1000 = lbs 96 97: Span Tension Floating point number sent as long integer * 1000 in units of lbs, read & write. Span Tension has a range of 1 to 10,000 lbs and represents the load seen by the load cells when a known web tension is applied that is less than the Maximum Tension Setpoint. Example: lbs Register 96: 5 (msw) Register 97: (lsw) Span Tension = ((5 * 65536) ) / 1000 = lbs 93: Load Cell Measure Flag Sent as integer, read & write. Load Cell Measure Flag is only used after Tare Tension and Span Tension registers have been written. 1. Remove any web tension from the tension sensing roller and then write a 1 to Load Cell Measure Flag. This calibrates the load cell tare condition. 2. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the tare calibration takes 10 seconds. Calibration step is complete when fl ag = Apply the web tension load that was sent to Span Tension register and then write a 2 to Load Cell Measure Flag. This calibrates the load cell span condition. 4. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the span calibration takes 6 seconds. Calibration step is complete when fl ag = Remove any web tension from the tension sensing roller and write a 3 to Load Cell Measure Flag. This checks the load cell tare condition. 6. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the tare check takes 2 seconds. Calibration step is complete when fl ag = 0. Load Cell Calibration Set 1 is now calibrated. Calibration Set : Tare Tension Floating point number sent as long integer * 1000 in units of lbs, read & write. Tare Tension is typically set to 0 and represents the web tension at the tare condition when the load cells measure only the weight of the tension sensing roller and its associated hardware : Span Tension Floating point number sent as long integer * 1000 in units of lbs, read & write. Span Tension has a range of 1 to 10,000 lbs and represents the load seen by the load cells when a known web tension is applied that is less than the Maximum Tension Setpoint. 93: Load Cell Measure Flag Sent as integer, read & write. Load Cell Measure Flag is only used after Tare Tension and Span Tension registers have been written. 1. Remove any web tension from the tension sensing roller and then write a 4 to Load Cell Measure Flag. This calibrates the load cell tare condition. 2. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the tare calibration takes 10 seconds. Calibration step is complete when fl ag = Apply the web tension load that was sent to Span Tension register and then write a 5 to Load Cell Measure Flag. This calibrates the load cell span condition. 12

16 4. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the span calibration takes 6 seconds. Calibration step is complete when fl ag = Remove any web tension from the tension sensing roller and write a 6 to Load Cell Measure Flag. This checks the load cell tare condition. 6. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the tare check takes 2 seconds. Calibration step is complete when fl ag = 0. Load Cell Calibration Set 2 is now calibrated. Calibration Set : Tare Tension Floating point number sent as long integer * 1000 in units of lbs, read & write. Tare Tension is typically set to 0 and represents the web tension at the tare condition when the load cells measure only the weight of the tension sensing roller and its associated hardware : Span Tension Floating point number sent as long integer * 1000 in units of lbs, read & write. Span Tension has a range of 1 to 10,000 lbs and represents the load seen by the load cells when a known web tension is applied that is less than the Maximum Tension Setpoint. 93: Load Cell Measure Flag Sent as integer, read & write. Load Cell Measure Flag is only used after Tare Tension and Span Tension registers have been written. 1. Remove any web tension from the tension sensing roller and then write a 7 to Load Cell Measure Flag. This calibrates the load cell tare condition. 2. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the tare calibration takes 10 seconds. Calibration step is complete when fl ag = Apply the web tension load that was sent to Span Tension register and then write a 8 to Load Cell Measure Flag. This calibrates the load cell span condition. 4. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the span calibration takes 6 seconds. Calibration step is complete when fl ag = Remove any web tension from the tension sensing roller and write a 9 to Load Cell Measure Flag. This checks the load cell tare condition. 6. Read Load Cell Measure Flag to determine when previous calibration step is complete. Under normal conditions, the tare check takes 2 seconds. Calibration step is complete when fl ag = 0. Load Cell Calibration Set 3 is now calibrated. 13

17 WARRANTY Warranties Nexen warrants that the Products will be free from any defects in material or workmanship for a period of 12 months from the date of shipment. NEXEN MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. This warranty applies only if (a) the Product has been installed, used and maintained in accordance with any applicable Nexen installation or maintenance manual for the Product; (b) the alleged defect is not attributable to normal wear and tear; (c) the Product has not been altered, misused or used for purposes other than those for which it was intended; and (d) Buyer has given written notice of the alleged defect to Nexen, and delivered the allegedly defective Product to Nexen, within one year of the date of shipment. Exclusive Remedy The exclusive remedy of the Buyer for any breach of the warranties set out above will be, at the sole discretion of Nexen, a repair or replacement with new, serviceably used or reconditioned Product, or issuance of credit in the amount of the purchase price paid to Nexen by the Buyer for the Products. Limitation of Nexen s Liability TO THE EXTENT PERMITTED BY LAW NEXEN SHALL HAVE NO LIABILITY TO BUYER OR ANY OTHER PER- SON FOR INCIDENTAL DAMAGES, SPECIAL DAMAGES, CONSEQUENTIAL DAMAGES OR OTHER DAM- AGES OF ANY KIND OR NATURE WHATSOEVER, WHETHER ARISING OUT OF BREACH OF WARRANTY OR OTHER BREACH OF CONTRACT, NEGLIGENCE OR OTHER TORT, OR OTHERWISE, EVEN IF NEXEN SHALL HAVE BEEN ADVISED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH POTENTIAL LOSS OR DAMAGE. For all of the purposes hereof, the term consequential damages shall include lost profi ts, penalties, delay images, liquidated damages or other damages and liabilities which Buyer shall be obligated to pay or which Buyer may incur based upon, related to or arising out of its contracts with its customers or other third parties. In no event shall Nexen be liable for any amount of damages in excess of amounts paid by Buyer for Products or services as to which a breach of contract has been determined to exist. The parties expressly agree that the price for the Products and the services was determined in consideration of the limitation on damages set forth herein and such limitation has been specifi cally bargained for and constitutes an agreed allocation of risk which shall survive the determination of any court of competent jurisdiction that any remedy herein fails of its essential purpose. Limitation of Damages In no event shall Nexen be liable for any consequential, indirect, incidental, or special damages of any nature whatsoever, including without limitation, lost profi ts arising from the sale or use of the Products. Warranty Claim Procedures To make a claim under this warranty, the claimant must give written notice of the alleged defect to whom the Product was purchased from and deliver the Product to same within one year of the date on which the alleged defect fi rst became apparent. Nexen Group, Inc. 560 Oak Grove Parkway Vadnais Heights, MN Fax: ISO 9001 Certified 14

RSTC1000 HMI/PLC Design Guide WEB CONTROL PRODUCTS. User Manual FORM NO. L B MTY (81)

RSTC1000 HMI/PLC Design Guide WEB CONTROL PRODUCTS. User Manual FORM NO. L B MTY (81) WEB CONTROL PRODUCTS User Manual RSTC1000 HMI/PLC Design Guide DANGER Read this manual carefully before installation and operation. Follow Nexen s instructions and integrate this unit into your system

More information

TCD600 OPEN LOOP TENSION CONTROLLER INSTALLATION, OPERATION MANUAL ADDENDUM (NETWORK FEATURE)

TCD600 OPEN LOOP TENSION CONTROLLER INSTALLATION, OPERATION MANUAL ADDENDUM (NETWORK FEATURE) TCD600 OPEN LOOP TENSION CONTROLLER INSTALLATION, OPERATION MANUAL ADDENDUM (NETWORK FEATURE) INTRODUCTION Nexen s TCD600 is a LonWorks compatible controller. It has a unique networking feature which enables

More information

MODBUS MANUAL For the AccUView UV Transmission Monitor

MODBUS MANUAL For the AccUView UV Transmission Monitor MODBUS MANUAL For the AccUView UV Transmission Monitor HF scientific, inc. 3170 Metro Parkway Ft. Myers, FL 33916 Phone: 239-337-2116 Fax: 239-332-7643 E-Mail: info@hfscientific.com Website: www.hfscientific.com

More information

FTC-200 X-ray Tube Controller Users Manual

FTC-200 X-ray Tube Controller Users Manual Tubes FTC-200 X-ray Tube Controller TUB-MAN-2101 Rev. A 09/09/2009TTUB Table of Contents List of Tables...3 List of Figures...3 Introduction...3 Manual Set...3 About this Manual...4 X-Ray Safety Information...4

More information

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World!

Operating Bulletin MODBUS-RTU. The Fastest Flow Controller Company in the World! Operating Bulletin MODBUS-RTU The Fastest Flow Controller Company in the World! 1 Notice: Alicat Scientific, Inc. reserves the right to make any changes and improvements to the products described in this

More information

DeviceNet Expansion Board

DeviceNet Expansion Board DeviceNet Expansion Board Catalog No. EXBD05 Installation and Operating Manual 10/02 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

INTMOD485-LH Protocol Converter

INTMOD485-LH Protocol Converter For Use with L-GAGE LH Series Sensors Features Converts an LH Network to the 485-RTU protocol Supports baud rates up to 230,400 baud Supports LH Networks with up to 32 sensors Model Protocol Conversion

More information

CL-9 Linear Fader Controller for the 788T Digital Recorder

CL-9 Linear Fader Controller for the 788T Digital Recorder CL-9 Linear Fader Controller for the 788T Digital Recorder E7556 State Rd. 23 and 33 Reedsburg, WI USA +1 (608) 524-0625 fax: +1 (608) 524-0655 Toll-Free: (800) 505-0625 www.sounddevices.com support@sounddevices.com

More information

EZ-LIGHT K50 Modbus Series Pick-to-Light Sensors

EZ-LIGHT K50 Modbus Series Pick-to-Light Sensors EZ-LIGHT K50 Modbus Series Pick-to-Light Sensors Datasheet Compact, single-point devices for error-proofing of bin-picking operations Fixed field and polarized retroreflective models Capacitive touch models

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

PIM-Mini Pulsed Current Source Operation Manual

PIM-Mini Pulsed Current Source Operation Manual PIM-Mini Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0007

More information

QPP Proprietary Profile Guide

QPP Proprietary Profile Guide Rev. 04 April 2018 Application note Document information Info Content Keywords Proprietary Profile, Server, Client Abstract The Proprietary Profile is used to transfer the raw data between BLE devices.

More information

Modbus Communication Module Functional Specification FS-0053

Modbus Communication Module Functional Specification FS-0053 Modbus Communication Module Functional Specification FS-0053 11 Continental Blvd Merrimack NH 03054 v. (603) 546-0090 f. (603)386-6366 oztekcorp.com About Oztek Oztek Corp. is proven innovator of power,

More information

CL-8. User Guide and Technical Information

CL-8. User Guide and Technical Information CL- User Guide and Technical Information E7556 State Highway 23 and 33 Reedsburg, WI USA 53959 +1 (60) 524-0625 fax: +1 (60) 524-0655 Toll-Free: (00) 505-0625 www.sounddevices.com support@sounddevices.com

More information

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display VP Process Inc. Model: Modbus RTU LCD Display User Manual Ver: 2.0 Aug. 2017 P a g e 1 Standard Features Low Power (12-24 VDC) 2.1 x 5mm Barrel Plug, RJ45 and Terminal Block Input On-Board Local Temperature

More information

Entrust SSL Web Server Certificate Subscription Agreement

Entrust SSL Web Server Certificate Subscription Agreement Entrust SSL Web Server Certificate Subscription Agreement ATTENTION - READ CAREFULLY: THIS SUBSCRIPTION AGREEMENT (THIS "AGREEMENT") IS A LEGAL CONTRACT BETWEEN THE PERSON, ENTITY, OR ORGANIZATION NAMED

More information

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols USER MANUAL Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols Contents at a Glance: Section 1 General Information RM-PS-024-01F 3 Section

More information

Woolich Racing. USB ECU Interface User Guide

Woolich Racing. USB ECU Interface User Guide Woolich Racing USB ECU Interface User Guide 1) Introduction This user guide covers how to use the Woolich Racing USB ECU Interface. This includes: Connecting the USB ECU Interface into the Bike Harness

More information

MODBUS MANUAL For the CLX Online Chlorine Analyzer

MODBUS MANUAL For the CLX Online Chlorine Analyzer MODBUS MANUAL For the CLX Online Chlorine Analyzer HF scientific, inc. 3170 Metro Parkway Ft. Myers, FL 33916 Phone: 239-337-2116 Fax: 239-332-7643 E-Mail: info@hfscientific.com Website: www.hfscientific.com

More information

End User License Agreement

End User License Agreement End User License Agreement Kyocera International, Inc. ( Kyocera ) End User License Agreement. CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS ( AGREEMENT ) BEFORE USING OR OTHERWISE ACCESSING THE SOFTWARE

More information

Profibus DP Expansion Board

Profibus DP Expansion Board Profibus DP Expansion Board Catalog No. EXBD04 Installation and Operating Manual 10/02 MN1393 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

GASGUARDIAN RD3 Remote Display OPERATING & INSTALLATION MANUAL

GASGUARDIAN RD3 Remote Display OPERATING & INSTALLATION MANUAL GASGUARDIAN RD3 OPERATING & INSTALLATION MANUAL 3GasGuardian RD Operating and Instruction Manual Table of Contents General description... 4 Installation... 4 Locating the GasGuardian RD1... 4 Installation

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-2 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-485 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

PCM-7140 Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects

More information

CAN Fiber Optic Modem

CAN Fiber Optic Modem User Manual for the HE200CFM100 CAN Fiber Optic Modem Second Edition 17 September 1999 MAN0007-02 PREFACE 17 SEPT 1999 PAGE 3 PREFACE This manual explains how to use the Horner APG s CAN Fiber Optic Modem.

More information

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 - HOUSTON TX 77041-8943 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

Entrust WAP Server Certificate Relying Party Agreement

Entrust WAP Server Certificate Relying Party Agreement Entrust WAP Server Certificate Relying Party Agreement The WAP/WTLS specification v1.1 does not provide a means for certificate revocation checking. The following Relying Party Agreement" provides further

More information

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 HOUSTON TX 77041-8943 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 202 SAFETY NOTICE Universal Interface Device 47 (UID47) connects two

More information

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount Fiber-Optic Link to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount 101-0079 Installation Operation & Specifications Manual Auto-direcon control Supports BAUD rates up to 115,200 Fiber

More information

I/O Expansion Box Installation & Operator s Instruction Manual

I/O Expansion Box Installation & Operator s Instruction Manual I/O Expansion Box Installation & Operator s Instruction Manual May 2004 CTB Inc. Warranty I/O Expansion Box CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

MTS-2000 USER S MANUAL

MTS-2000 USER S MANUAL MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this

More information

THECHARGEHUB.COM. User Manual. For Square & Round Models

THECHARGEHUB.COM. User Manual. For Square & Round Models THECHARGEHUB.COM User Manual For Square & Round Models User Manual THECHARGEHUB.COM 7-Port USB Universal Charging Station Table of Contents General Safety Information...2 Care and Maintenance...3 Introduction...4

More information

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions BlueGuard FE Bluetooth Enabled Access Control MODEL BG-FE Operating Instructions CAUTION AND SAFETY INFORMATION IMPORTANT: If the equipment is used in a manner not specified in this manual, the protection

More information

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort, CPU42 RUN ERR/ALM INH PRPHL/COMN OPEN MCPWR BUSY OPEN PERIPHERAL PORT (RS-232C) CS-series B7A Interface Unit CSM DS_E_3_2 It transmits 16 points of I/O signals per word with a pair of cables. Easy and

More information

ME15 Magnetic Encoder Manual Revision 1.1

ME15 Magnetic Encoder Manual Revision 1.1 Product Overview The ME15 Magnetic Encoder is the newest addition to AMCI s Encoder product line. The encoder is designed for lower resolution and lower cost applications and provides 10 bits of resolution.

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

Powered Roller Controller for DeviceNet

Powered Roller Controller for DeviceNet PRC-620-090 TECHNICAL DATA Description The Holjeron Powered Roller Controller for use with DeviceNet has the features needed to handle up to four zones in a material handling system. A Brushless DC Powered

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

SGJ Cable Actuated Sensor Industrial CANBus J1939

SGJ Cable Actuated Sensor Industrial CANBus J1939 Cable Actuated Sensor Industrial CANBus J939 Two Available Stroke Ranges: 0-80 in & 0-20 in. Rugged Polycarbonate Enclosure Simple Installation Compact Design Built for IP67 environments IN STOCK FOR QUICK

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications. Safety Network Controller NEA-SCPU Series CSM_NEA-SCPU_Series_DS_E Achieve Safety Control through Programming. Compact Safety Controller. The NEA-SCPU-V provides built-in safety inputs and 8 built-in safety

More information

PC 150. Digital Bench Scale. Operation Manual

PC 150. Digital Bench Scale. Operation Manual PC 150 Digital Bench Scale Operation Manual Revision 1.2 September 14, 2000 1996-2000 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 35 Waltz Drive Wheeling,

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications Manufactured in ISO9000:2000 Facility Items Conform to AISI 304 / 316 Investment Cast SP114 Stainless Fittings

More information

Brushless DC Motor Controller Specification Assembly 025A0053

Brushless DC Motor Controller Specification Assembly 025A0053 Brushless DC Motor Controller Specification Assembly 025A0053 600A0053 Rev. 2 July 28, 2004 025A0053 Brushless DC Motor Controller Data Sheet Page 1 Revision History Date Rev Description By 5/15/04 1 Initial

More information

PMDX-170 Slotted Optical Sensor

PMDX-170 Slotted Optical Sensor PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc

More information

Install Motor Controller User Manual

Install Motor Controller User Manual Property of Motion Laboratories, Inc. Install Motor Controller User Manual 2014 Motion Laboratories, Inc. Created By: Michael Shaw Approved By: John Coppolecchia Page: 1 Page: 2 2014 Motion Laboratories,

More information

ACLD Channel Opto-isolated Digital Input Board

ACLD Channel Opto-isolated Digital Input Board ACLD-9182 16 Channel Opto-isolated Digital Input Board @ Copyright 1996 All Rights Reserved. Manual edition 01, January 1996 The information in this document is subject to change without prior notice in

More information

SNT-E RT 10.4 VGA TFT with Touch Screen Display Module Powered By SegeNT embedded GUI Board Hardware Manual

SNT-E RT 10.4 VGA TFT with Touch Screen Display Module Powered By SegeNT embedded GUI Board Hardware Manual HAIDAR TECHNOLOGY, LLC. The Next Generation Of Intelligent Embedded GUI Systems WWW.haidartechnology.com (614) 389-3022 Sales@haidartechnology.com SNT-E640480-104-RT 10.4 VGA TFT with Touch Screen Display

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

Relay Board. User Manual. 1.0, Oct 2013

Relay Board. User Manual. 1.0, Oct 2013 Relay Board User Manual 1.0, Oct 2013 This work is licensed under the Creative Commons Attribution-Share Alike 2.5 India License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/2.5/in/

More information

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring. CQM1 I/O CSM_CJ1W-AT4 DS_E_1_1 Easy and secure replacement by reusing the I/O terminal block wiring You can replace CQM1(H) Series with CJ Series, efficiently using your assets. Time for wiring works and

More information

Spec Tech Industrial Electric Technical Support. Model: DL34-(XX) Quick Start

Spec Tech Industrial Electric Technical Support. Model: DL34-(XX) Quick Start Technical Support For complete product documentation, video training, and technical support, go to www.flowline.com. For phone support, call 562-598-3015 from 8am to 5pm PST, Mon - Fri. (Please make sure

More information

PCMCIA Flash Card User Guide

PCMCIA Flash Card User Guide R R PCMCIA Flash Card User Guide For the CoreBuilder 3500 System Introduction The CoreBuilder 3500 PCMCIA Flash Card is a 20 MB flash card that you can use to save your system software. When you have saved

More information

Weather Station Display Software Rev A

Weather Station Display Software Rev A Weather Station Display Software 57-6058 Rev A This page intentional left blank. Page 2/16 Contents 1.0 NOTICES...4 1.1.1 1.1.2 1.1.3 1.1.4 Copyright...4 Manufacturer...4 Warranty Information...4 Product

More information

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual Contents HP E1586A Rack Mount Terminal Panel User s Manual Description... 5 Connecting to VXIbus Instruments... 5 Interconnect Cables... 5 Terminal Block Connections... 6 Using the Terminal Panel for Reference

More information

Thermocouple Input Module

Thermocouple Input Module User Manual for the HE150THM180 Thermocouple Input Module Fifth Edition April 01, 1998 MAN0004-05 PREFACE 4-01-98 PAGE 2 PREFACE This manual explains how to use Horner APG s Thermocouple Input module for

More information

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units. Sensor Communications Unit CSM DS_E_1_1 The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation Low initial cost achieved by distributed

More information

Extender for 1.3 over one CAT-6. EXT-HDMI1.3-1CAT6 User Manual

Extender for 1.3 over one CAT-6. EXT-HDMI1.3-1CAT6 User Manual Extender for 1.3 over one CAT-6 EXT-HDMI1.3-1CAT6 User Manual www.gefen.com Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual INC PBB-24 Plus Programmable Button Box Firmware version v 3.19 Manual Update: 06/10/2008 Due to the dynamic nature of product design, the information contained in this

More information

Data Reporter. Installation-Operation E rev.f

Data Reporter. Installation-Operation E rev.f Installation-Operation Data Reporter 309867E rev.f Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Part No. 246085 Records actual temperature,

More information

This application note is written for a reader that is familiar with Ethernet hardware design.

This application note is written for a reader that is familiar with Ethernet hardware design. AN 14.8 LAN8700/LAN8700I and LAN8187/LAN8187I Ethernet PHY Layout Guidelines 1 Introduction 1.1 Audience 1.2 Overview The LAN8700/LAN8700I and LAN8187/LAN8187I are highly-integrated devices designed for

More information

User Manual for XL-J1939

User Manual for XL-J1939 User Manual for XL-J1939 MAN0913-01 MAN0913-01 PREFACE PREFACE This manual explains how to use XL-J1939 Product. Copyright (C) 2002 Horner APG, LLC. S9. S. State Avenue, Indianapolis, Indiana 46201. All

More information

D12 Series DIN Rail High Power Fiber Optic Sensor

D12 Series DIN Rail High Power Fiber Optic Sensor Datasheet Powerful Self-Contained Sensors for Use with Glass or Plastic Fiber Optic Assemblies Fiber optic sensors for DIN rail mounting; cabled or quick disconnect (QD) Fast response: 500 μs standard,

More information

Pneumatic and Electric 2705 Commerce Pkwy., Auburn Hills, Michigan Ph: (248)

Pneumatic and Electric 2705 Commerce Pkwy., Auburn Hills, Michigan Ph: (248) Pneumatic and Electric Control Handles Index Introduction Overview...1 Control Handle Series Control Handle Series.... Servo Controls... Trigger Controls Series................... Balancer Controls...

More information

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS PRODUCT FEATURES MODELS: IIA SPRINT 310/510/710 200/250 2000 SERIES 3000 SERIES

More information

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr 24 2012 JNesbitt@GPS-US.co GPS updates

More information

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals. CS-series Net Unit CSM DS_E_5_3 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures

More information

InLinK HM Setup Software Installation & Operation Manual

InLinK HM Setup Software Installation & Operation Manual InLinK HM HART Protocol Modem Module with HART Device to Modbus Accumulator for OEM Applications 101-0014 Setup Software Installation & Operation Manual InLink-HM 101-0014 is a complete OEM HART protocol

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

ETConcept Systems Engineering. User s Guide

ETConcept Systems Engineering. User s Guide Wiegand to RS485 Converter User s Guide Nov-08 Copyright 2008. All rights reserved including the right of reproduction in whole or in part in any form. Contents List of Accessories Included... 1 List

More information

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL Transducer Techniques R 42480 RIO NEDO, TEMECULA, CA 92590 (909) 719-3965 FAX (909) 719-3900 URL: http://www.ttloadcells.com E-mail: tti@ttloadcells.com

More information

Miniature Overhead Stirrer

Miniature Overhead Stirrer KEM Scientific, Inc. Instruments for Science from Scientists J-KEM Scientific, Inc. 6970 Olive Blvd. St. Louis, MO 63130 (314) 863-5536 Fax (314) 863-6070 E-Mail: jkem911@jkem.com Miniature Overhead Stirrer

More information

AnalogBridge Analog transmission system

AnalogBridge Analog transmission system AnalogBridge Analog transmission system Enclosure showing RTU Module and optional Power supply, External Relay User Guide Revision 1.4 Wireless Solutions at Work www.orbitcoms.com Page 1 Orbit Communications

More information

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

Wall. No opening (Example: LA-030-W)

Wall. No opening (Example: LA-030-W) Thank you very much for choosing an EIZO product. Please read this User s Manual carefully to familiarize yourself with safe and effective usage procedures. Please retain this manual for future reference.

More information

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION FEATURES Individually digitized transducer data Continuous Expert System diagnostics Dynamic digital filtering 750,000 count resolution psr channel 20 updates/sec. Multi-function set-up and calibration

More information

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales

More information

RS485 MODBUS Module 8AO

RS485 MODBUS Module 8AO Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Modbus RTU Slave Driver is available within the following MicroLogix PLCs

Modbus RTU Slave Driver is available within the following MicroLogix PLCs TECH NOTES-303 Integrating RACO Verbatim Gateway and Allen-Bradley MicroLogix via Modbus RTU over RS232 This technical note explains how to interface the RACO Verbatim Gateway system with the Allen-Bradley

More information

HDMI Extender over Cat5e/6

HDMI Extender over Cat5e/6 Statement Thanks for purchasing this product, please read this user manual carefully before using this product.in the constant effort to improve our product, we reserve the right to make functions or parameters

More information

zpen-1080p Features zpen-1080p Layout

zpen-1080p Features zpen-1080p Layout 1 zpen-1080p Features CMOS image sensor with Low Light sensitivity HD 1080P up to 30fps, 720P up to 60fps H.264 compression Built-in micro SD card, supports up to 32GB One button operation Easily download

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

INSTRUCTION and OPERATIONS MANUAL. for

INSTRUCTION and OPERATIONS MANUAL. for INSTRUCTION and OPERATIONS MANUAL for CAB SIGNAL MASTER MODEL NUMBER 15100-00 CAUTION Be sure to read and become thoroughly familiar with the entire contents of this manual before attempting to operate

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216

More information

Motorized Filter Wheel FW-MOT-12.5 / FW-MOT-25

Motorized Filter Wheel FW-MOT-12.5 / FW-MOT-25 Motorized Filter Wheel FW-MOT-12.5 / FW-MOT-25 Andover Corporation 4 Commercial Drive Salem, New Hampshire 03079-2800 Tel: (603) 893-6888 US Toll Free: (888) 893-9992 Fax: (603) 893-6508 Email: techstaff@andovercorp.com

More information

Ludlum Lumic Data Logger Software Manual Version 1.1.xx

Ludlum Lumic Data Logger Software Manual Version 1.1.xx Ludlum Lumic Data Logger Software Manual Version 1.1.xx Ludlum Lumic Data Logger Software Manual Version 1.1.xx Contents Introduction... 1 Software License Agreement... 2 Getting Started... 5 Minimum

More information

Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL

Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL Congratulations on your purchase of the Mini USB-2 Extender. Your complete satisfaction is very important to us. Gefen Gefen delivers innovative, progressive

More information

CsCAN Data Concentrator Module

CsCAN Data Concentrator Module User Manual for the HE693CDC200 CsCAN Data Concentrator Module Second Edition 24 September 2001 MAN0283-02 MAN0283-02 24 SEP 2001 PAGE 3 PREFACE This manual explains how to use the Horner APG s CsCAN

More information

SMA OneTouch ICS Environmental Monitoring System REMOTE MONITORING GUIDE

SMA OneTouch ICS Environmental Monitoring System REMOTE MONITORING GUIDE Rev 1 04NOV2015 SMA OneTouch ICS Environmental Monitoring System REMOTE MONITORING GUIDE SMA ONETOUCH ICS WARRANTY warrants all equipment manufactured by and bearing its name to be free from defects in

More information

User Manual. Spectrum Pro

User Manual. Spectrum Pro 80140502-001 User Manual Spectrum Pro PCI PTS 4.X Hybrid Insert Reader RS232 Interface 80140502-001 Rev 51 3/10/2015 International Technologies & Systems Corporation 10721 Walker Street, Cypress, CA 90630-4720;

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking ! Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking All Rights Reserved 1997-2017 Enable-IT, Inc. INSTALLING THE 821 ETHERNET EXTENDER The Enable-IT 821 Ethernet Extenders

More information

TSD-SEQ6 Sequencer Controller

TSD-SEQ6 Sequencer Controller Owner s Manual 1 AtlasSound.com Owner s Manual Description The Atlas Sound features 6 outputs that are configurable individually to be either a 24VDC output or Hard Switch Contact Closure (CC). There are

More information