1 Changes Guide Premier Series - From V15.04 to V16 INS643-2
2 Contents Premier Series V15.04 tov16 Changes Guide 1. Contents 1. Contents Introduction... 3 Bug Fixes... 3 Improvements... 3 New Features Panel Start-up procedure... 3 Premier RKP8 & 16 LED Keypads... 3 Premier LCD Keypads Configuration Options :EN50131 Options Misc Options :Misc Options Other Features & Functions... 6 Confirm Devices... 6 User Time & Date Menu... 7 System Outputs... 7 Allow Reading and Editing of Zone Text with Simple Protocol... 7 Global System Timers New Log Events... 7 Speech Module... 7 Walktest Reset... 7 Keypad Fault Indications... 7 Partition Timers Entry Delay Wintex Changes... 8 Wintex Configuration Options... 8 Misc Options Language Changes... 9 Language Sets Premier INS643-2
3 2. Introduction Premier Firmware has undergone some major changes, focussed mainly on the changing requirements of international standards, but also encompassing feature changes requested by our customers. This document details the major changes between V15 & V16 firmware. Bug Fixes Over 60 minor "Bugs" have been fixed during Internal Testing; the majority of these were never seen in the field. Some of the Improvements listed below may have been made following the reporting of a "Bug" or the general operation and function of the panel. Improvements Several Improvements have been made in V16. None of these require any programming they are simply a better way of doing things, or as a result of a customer request. Com Port Fault Indications Changes made to specify which Com Port is in fault. If both Com ports are in fault, the Com Faults will alternate between the 2 ports. All languages modified to support this enhancement. Reporting Codes 1. New SIA code YT added for Radio Supervision fault restore. This will both be logged and reported. 2. Reporting added for Device low battery. When using Contact ID or SIA Low Battery notifications will be reported. Ricochet Changes 1. Any Ricochet devices including FOBs will now search for the first available free slot and map itself there. The mapping for ALL devices including FOBs will start from 0 and upwards until it reaches the maximum number of devices for the panel used.. 2. New message added for indicating Radio low battery to the User. 3. Ricochet Devices with same serial number will be dealt with correctly by considering the device type also. Panel Outputs Panel Outputs 3&4 will be set to "Not Used" when the Speech module is configured on Keypad or in Wintex. ComIP 1. Any changes to any of the ComIP details will cause the ComIP to initialize correctly. 2. In addition to this changes have been made to ensure the ComIP does not start re-configuring while the Engineer is still logged in. Wintex UDL Connections Wintex UDL connections will be dropped if a priority alarm has to be reported. New Features The new features added to the panel have been implemented to satisfy the requirements of changing standards in various countries, and requests from customers. The majority of the key changes are too the Global Options menu and Configuration Options, and Misc Options. Other new features are listed separately. Some of these new features have resulted in changes to Wintex which are detailed later. 3. Panel Start-up procedure V16 sees a new start-up procedure allowing selection of the control panel language, loading specific country defaults and confirming devices connected to the panel network at start-up. Premier RKP8 & 16 LED Keypads For LED keypads there is no change to the current operation. Bypassing the requirement to set the language and country code at initial power up is as follows. Power up the panel Enter the default engineers code Press / then 9 You are now in the programming menu and can continue as you did with previous versions of the panel. INS
4 Premier LCD Keypads As with LED keypad operation, the requirement to set the language and country code can be bypassed. The procedure is identical to that shown for LED keypads. Change the Language On powering up the panel the following sequence will be presented. You can exit this procedure at anytime by using the keys detailed in the Options column. Action Display Options Enter the default engineers code Press / and use the key to select the desired language Press / to confirm Language Press / and use the numeric keys to enter the desired country code. The panel will now load the defaults for the country code selected. Press / and check that all devices installed are shown. Press /. Press /. Press / and use the numeric keys to enter the correct time. You will be prompted to programme the correct date Press / and use the numeric keys to enter the correct date. You are now at the Programming Menu Press / takes you to the Programming Menu Press / takes you to the Programming Menu Press / takes you to day mode. You will be prompted to confirm devices when you log in again. Press / takes you to day mode. You will be prompted to confirm devices when you log in again. Press / takes you to the Programming Menu Press / takes you to the Programming Menu Press / takes you to the Programming Menu Press / takes you to the Programming Menu Press / takes you to day mode Press / takes you to day mode If confirm devices is not carried out you will be prompted every time you login as an engineer to carry out this function. If the date & time are not set then the engineer or user will be prompted when they login, and each time until the date and time are set. 4 INS643-2
5 4. Configuration Options The table below details the changes between V15 & V16. Each new feature is explained following this table. Menu 33:System Options 1 34:System Options 2 35:System Options 3 Description V15 & V16 are identical V15 & V16 are Identical V15 & V16 are Identical 36: Hardware Options V15 & V16 are Identical 39:EN50131 Options New in V16 in V15 firmware 39 was used for Misc. Options 2. The Misc options 2 in V16 are now 38.2 See section on Misc Options changes. 39:EN50131 Options include the following new features and functions:- Confirm Low Fob Battery on Arm On = An arming fob with a low battery causes a warning to be indicated. The user must acknowledge the warning before arming can continue. The Low Battery and acknowledgement are logged. Off = An arming fob with a low battery arms the system. Soak Test Active Arm Indication On = A zone in Soak Test being armed will cause the Soak Test Warning to be displayed. The user can then continue to arm or return to the day mode. If such a warning is to be displayed before arming, then Fault LED 1 (Service fault LED 1) is set Off = The Soak Test Warning message is not displayed. Soak Test Acknowledge Required On = Soak test warnings must be acknowledged by the user. Off = Soak test warnings are only displayed for 2 seconds before arming continues. Entry Stray Notification Delay. An entry stray occurs when a Zone NOT on the entry route is activated during the Entry Time. On = Entry stray notification is delayed after the alarm is raised. Off = Entry stray notification occurs when the alarm is raised. Entry Timeout Notify Delay On = Entry timeout notification is delayed when the alarm is raised. Off = Entry timeout notification occurs when the alarm is raised. Cable Cut Expander Tamper This option also applies to Keypad cables. In the event that a cable is cut, or shorted to any expander, a Tamper alarm will occur and be signalled. If the expander or keypad is lost as a result, any devices connected to the expander or keypad will also go into alarm. Depending on panel configuration this may cause a "Confirmed" activation. On = A cable cut expander signals a tamper alarm. Off = A cable cut expander does not signal a tamper alarm. User Code Entry Timed A User Code entry must be completed in 60 seconds. ( After every 10 invalid code entry attempts all the keypads are locked out for 90 seconds. After 21 invalid code entry attempts a keypad tamper event is raised) On = A user s code must be entered in 60 seconds. Off = User code validity is by number of characters entered. Power Failure Latch Mains and Battery failures are latched and must be acknowledged by the user On = Mains and Battery failures are latched to enable user notification. Off = Mains and Battery failures are only shown when present. INS
6 5. Misc Options The table below details the changes between V15 & V16. Each new feature is explained following this table. Menu 37:Auxiliary Input 38.1:Misc Options :Misc Options : Misc Options 3 Description V15 & V16 are identical New in V16 Was 38:Misc Options 1 in V15 no additional features just a menu number change. New in V16 Was 39:Misc Options 2 in V15 no additional features just a menu number change. New in V :Misc Options 3 Includes the following new features and functions Enable User Reset for Tampers On = Users can reset Tamper Alarms Off = Tamper Alarms can only be reset by an Engineer Allow Engineer Access when Armed On = When Areas are Armed an Engineer can access programming menus providing they have been enabled by a Master user. Off = an Engineer cannot access any menus if an Area is armed. 6. Other Features & Functions Confirm Devices A new menu option has been added to allow Confirming of devices manually by the Engineer. This function is ONLY available on LCD keypads. To access the menu in future if you are adding extra network components please follow this procedure. Enter Engineer Code Press Menu Press again Press / Press / The Expanders & Keypads installed will now show Press / Press / to Confirm Press to exit programming. 6 INS643-2
7 User Time & Date Menu The Date & Time menu will be shown to a user when they log-in, if the date & time needs to be set. For an engineer, Confirm devices will be shown first if required. After Confirm devices, if the Engineer logs out and logs in then the date & time menu will be shown. For Users the arming functionality is un-affected. System Outputs Output Type 36 A new System output type # 36 will now be available as 'Poll Timer'. This output is linked to the Global System Timer 14 "Poll IP Every" in minutes. Thus if this timer is programmed with a non-zero value, when the timer times out, this new output "Poll Timer" will activate for 10 seconds and then reset. This cycle will repeat every time the "Poll IP Every" timer expires. New Outputs 34 & 35 Two new output types have been added. a. Output Type 34 AC Fail b. Output Type 35 Battery Fail Outputs 8 & 21 Renamed c. Output 8 renamed from AC Fail to Latched AC Fail d. Output 21 renamed from Battery Fault to Latched Battery Fault Allow Reading and Editing of Zone Text with Simple Protocol If the Simple Protocol is used to interface the control panel with other equipment, it is now possible to view and edit the Zone Text. Global System Timers 14 IP poll will not be sent if Wintex is connected to panel using IP. This relates to Montex as it may not get a poll messages if Wintex is connected. However it is also true of other remote connections which may expect an IP poll. New Log Events Auto Arm Failure If the system is programmed to Auto Arm using a Control Timer and the Arming fails, the failure will be logged. Three of the same event Only 3 events of the same type from a single source will be logged during one set event. Com port Remote Commands The following Remote Commands are now added to the Event Log a. Partitions Reset b. Remote Arming c. Remote Zones Unbypassed d. Site Data Change via Wintex Users When Users are added or deleted from the system, this will be recorded in the Log User Acknowledgement, for example arming with Zones in Soak Test. Tamper Alarms & Restores e. Keypad Tampers & Restores are logged f. Box Tamper Restores are logged Speech Module # Key Speech calls can be terminated by the user using the # key on their telephone Abort calls from site Menu + 7 can be used to Abort Speech Module calls from the site keypad by the User. Walktest Reset When an engineer is using the Walktest function, System Utilities, 90 pressing the Reset key will clear all previously walktested zones. Keypad Fault Indications New indications have been added for both LED & LCD keypads. Fault indications on LCD keypads will display the text, LED keypad lights will indicate as follows:- General Warnings Press to view the warning, lights 1-5 indicate:- 1. AC Fail 2. Arming Fob has Low Battery 3. Soak Test Active Box Tamper & Auxiliary Input: Press to view type, lights 1-8 indicate: 1. Box Tamper 2. Auxiliary Tamper 3. Auxiliary PA 4. Auxiliary Tamper (UK Bell Module Only) 5. Bell Tamper (UK Bell Module Only) 6. Radio Plus Tamper 7. Low Fob Battery 8. User Code Tamper Partition Timers Entry Delay 1 Partition Timers Entry Delay 1 default has been changed from 15 seconds to 30 seconds to comply with the requirements of EN INS
8 7. Wintex Changes Wintex has been changed following the implementation of the new features added to the Global menus. These can be seen in the images detailed below. The default state for the affected changes are also shown. Wintex Configuration Options V15 Config V16 Config 8 INS643-2
9 Misc Options V15 Misc Options V16 Misc Options 8. Language Changes Language Sets Premier 832 For V16 the available Language Sets for the Premier 832 have been increased to accommodate the new features and functions, and to allow for the addition of translated firmware. All other panels remain unchanged. New Language Sets LS1 English, Norske, Dansk LS2 Francias, Vlaams and Nederlands LS3 English, Polski, A Magyar LS4 English, Portugeus, Espanol LS5 English, Cestina, Slovensky LS6 English, Suomi, Svenska, LS7 English, Deutsch, Italiano LS8 English, Pyccko Additional Language Changes English strings added to all languages that do not have corresponding translations Spanish language updated Czech language updated Finnish language Bulgaria Country defaults added French language updated Enabled Chiron code for ALL language sets for all panels INS
10 Notes: 10 INS643-2
11 Notes: INS
12 Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: (Calls charged at local rate from a BT landline. Calls from other networks may vary.) International Customers Tel: techsupport@texe.com Texecom Limited 2015 INS643-2
Changes Guide Premier Elite Series - From V2.11 to V3.00
Changes Guide Premier Elite Series - From V2.11 to V3.00 INS660-2 Contents Premier Elite V2.11 to V3.00 Changes Guide 1. Contents 1. Contents... 2 2. Introduction... 3 3. Bug Fixes... 3 4. New Premier
More informationV4 Changes Guide Premier Elite Series
V4 Changes Guide Premier Elite Series INS765 Contents Premier Elite V4.00 Changes Guide 1. Contents 1. Contents... 2 2. Introduction... 3 Bug Fixes... 3 Texecom Connect... 3 3. Texecom Connect Servers...
More informationInstallation Manual Premier Elite ComIP
Installation Manual Premier Elite ComIP INS273-6 Product Type - CEJ0000 1. Overview Introduction The ComIP module allows the Premier & Premier Elite control panels to be connected to either a Local Area
More informationMAINTEX. User Guide INS571
TM MAINTEX User Guide INS571 Contents Contents... 2 Introduction... 3 Installation... 3 Starting Maintex... 3 User Logon... 4 How to create a new Operator... 5 Connection Setup... 7 Modem Setup... 8 Network
More informationTHANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.
More informationMG/SP Series (V4.9/V5.1) What s New
MG/SP Series (V4.9/V5.1) What s New Firmware: SP4000 and SP5 version 5.1 SP5500, SP000, SP7000, and MG5050 version 4.9 (SP5500 pictured) Overview: New Programming Sections New Events New Trouble Display
More information2015/09/24. M-Touch
M-Touch 2.00.12 VERSION HISTORY (> 1.00) Graphics Maps: by means of Graphic Maps it s possible to display the alarm zones simply by tapping icons on the map shown on keypad screen. It s very simple to
More informationInstallation Manual Premier Elite ComGSM
Installation Manual Premier Elite ComGSM INS315-4 1. Introduction The Premier Elite Com GSM is a 2G module that can be connected to any Premier or Premier Elite control panel; however functionality differs
More informationTexecom Connect Guide INS760
Texecom Connect Guide INS760 1. Introduction Texecom s Premier Elite Series is the perfect security system for modern connected homes and buildings. Texecom s Premier Elite Series provides a single, comprehensive
More informationInstallation Manual Premier 8XP. Issue 4
Installation Manual Premier 8XP Issue 4 Introduction This manual is intended for version 9 expanders and above. To identify the expander version number, check the label on the processor chip in the PCB.
More informationSeries. NX-8-EUR Control Panel. Installation manual
g GE Security NetworX TM Series NX-8-EUR Control Panel Installation manual NX-8-EUR Installation manual Page 2 23/12/04 CONTENTS CONTENTS...3 GENERAL INFORMATION...5 ORDERING INFORMATION...5 FEATURE DEFINITIONS...6
More informationTHANK YOU FOR VOTING TEXECOM USER MANUAL. Security Control Panels
THANK YOU FOR VOTING TEXECOM USER MANUAL Security Control Panels Contents Premier 888 & 8168 User Manual Contents 1. About the Alarm System... Introduction... Overview... User Codes... Zones... Global
More informationATLAS 8 PLUSTM USER GUIDE LED & LCD. Rins 160 Issue 2
ATLAS 8 PLUSTM USER GUIDE LED & LCD The equipment has been approved to CTR21for pan-european single terminal connection to the Public Switched Telephone Network (PSTN). However, due to differences between
More informationATLAS 8 PLUSTM USER GUIDE LED & LCD. Intelligent Security & Fire Ltd Rins 160 Issue 6
ATLAS 8 PLUSTM USER GUIDE LED & LCD 8! INSTALLER DETAI LS: 1 3 4 2 5 6 7 8 9 0 OR SET TELEPHO NE: The equipment has been approved to CTR21for pan-european single terminal connection to the Public Switched
More informationDigiplex EVO High Security and Access System What s New EVO192 V2.7
Digiplex EVO High Security and Access System What s New EVO192 V2.7 Overview New zone programming and additional zone/system/anti-mask options EN 50131 compliancy Now supports automatic label broadcast
More informationControl Panel Solution 2000 / 3000
Control Panel Solution 2000 / 3000 en Quick Reference Guide Control Panel Table of contents en 3 Table of contents 1 Introduction 6 2 Programming 7 2.1 Alphanumeric Codepad Menu Programming 7 2.2 ICON
More informationeurösec CPX Control Panel User Instructions
eurösec CPX Control Panel User Instructions eurösec CPX User Manual Contents User Information... 2 Introduction... 3 User Code Types... 3 Setting The System... 4 Setting & Unsetting via Keyswitch... 4
More informationFSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:
FSK TX CELLULAR PLUS Installation and Programming Guide Tel: 0861 105 962 www.fsk.co.za INTRODUCTION The FSK TX Cellular Plus (TXC+) is a highly featured GSM based unit which is used for the transmission
More informationTelephone and Reporting Setup in ElkRP
Telephone and Reporting Setup in ElkRP 1. To add a telephone, right click on Telephones under Folder items on the left side of the screen. Then select New Telephone. 2. On the New Telephone IDs screen,
More informationApplicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above.
Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above. Please note that this manual has been prepared to highlight the new PD6662, BS8243 and EN50131-1 features. RINS1530-1 CHAPTER
More informationEUROPLEX TECHNOLOGIES. WARNING. Copyright. Disclaimer
EUROPLEX TECHNOLOGIES. Company Web Site address: www.europlex.com Europlex Technologies [Ireland] Ltd. Clonshaugh Industrial Estate, Clonshaugh, Dublin 17, Ireland. Tel: +353-1 - 8485111 Fax: +353-1 -
More informationVISTA-128BP/VISTA-250BP Programming Form
VISTA-128BP/VISTA-250BP Programming Form Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system, see the Partition-Specific Fields section
More informationControl Panel. D9412GV4/D7412GV4/D7212GV4 v1.xx. Release Notes
Control Panel D9412GV4/D7412GV4/D7212GV4 v1.xx en Release Notes Control Panel Table of contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 1.1.1 Bosch Security Systems, Inc. product
More informationHigh Security and Access System EVO48 V2.1 EVO192 V2.1
High Security and Access System EVO48 V2.1 EVO192 V2.1 Programming Guide Includes LCD Keypad Programming We hope this product performs to your complete satisfaction. Should you have any questions or comments,
More informationKeypad LCD (software version 3.10) CA-10 plus
PROGRAMMING AND INSTALLATION MANUAL Keypad LCD (software version 3.10) CA-10 plus GDAŃSK ca10plci_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only. Because
More informationAvantis AXI WEB SERVER MODULE USER MANUAL
Avantis AXI WEB SERVER MODULE USER MANUAL CONTENTS CHAPTER 1: SYSTEM LOGIN AND WEB PAGE LAYOUT 1.0 ACCESSING THE WEB PAGE 1.1 USER AUTHORITY 1.1.1 MASTER USER 1.1.2 USER/ GUEST SETTING 1.1.3 INSTALLER
More informationPROGRAMMING HELP GUIDE
DIGIPLEX EVO48-192 PROGRAMMING HELP GUIDE Entering Programming Mode 1) Press and hold the [0] key 2) Enter your [Installer Code] (default-000000) 3) Enter 4-digit [section] you wish to program 4) Enter
More informationVISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control
VISTA 12a / 48a TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control Version #.007 7th June 2005 VISTA 12a / 48a Training Guide Index 1. Vista Family Features....... p. 3 2. Wiring
More information2 IDS LCD Keypad User Manual C Issued March 2009
2 3 4 Contents 1. Introduction to the IDS LCD Digital Keypad...8 2. Arming the Control Panel...8 2.1 Away Arming...8 2.1.1 How to Away Arm...8 2.1.2 Quick Away Arm Shortcut Key...8 2.2 Stay Arming...9
More informationContents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...
Contents 1. Introduction to the Watchguard WGAP864 LCD Digital Keypad... 6 2. Viewing Violated Zones... 6 3. Arming the Control Panel... 7 3.1 Away Arming... 7 3.1.1 How to Away Arm... 7 3.1.2 Quick Away
More information1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...
HWZRU;;( Control/Communicator Installation Manual Table of Contents General Description... Ordering Information... Feature Definitions... Programming the LED Keypads... Programming the NX-E...9 Types of
More informationD1260/D1260B. Owner's Manual. Keypad
D1260/D1260B EN Owner's Manual Keypad D1260/D1260B Owner's Manual This system includes a telephone line seizure feature. The system may be programmed to communicate with a central monitoring station to
More informationENABLE / DISABLE: ZONES, DEVICES, CIRCUITS, COMMUNICATION SENSE, RESET HI-LO LEVELS, WALKTEST DIAGNOSTICS
Cheetah Manual #06-148 page 55 CHAPTER 10 Operation (level 2 password) Menu options available under this level of access are: HISTORY: ALARM, EVENT, ZONE, CURRENT LEVEL PASSWORD: (ENTRY) 1 SPECIAL: LEVELS,
More informationImportant Notice. Customer Information. 2 WisDom User Manual
User Manual Important Notice This manual is delivered subject to the following conditions and restrictions: This manual contains proprietary information belonging to RISCO Group. The information is supplied
More informationINT-TSI Brief User Manual
int-tsi_u_en 03/15 Keypad INT-TSI Brief User Manual SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 info@satel.pl www.satel.eu Firmware version 1.04 WARNINGS Please read this
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationUser Guide Speech Dialler/Speech & Text Dialler. Issue 2
User Guide Speech Dialler/Speech & Text Dialler Issue 2 Contents Overview...3 Introduction... 3 Speech Dialler Layout... 6 Function Keys... 6 1. Programming...7 Accessing the Programming Menu... 7 Contact
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationQuick Start Reference Guide Series 9.x and 10.x Software
Quick Start Reference Guide Series 9.x and 10.x Software NOTE: This quick reference should only be used by persons who have read the Software User Guide and received training on the use of the System.
More informationMetasys Integrator Northern Application
Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Northern Application lntroduction Page *3 Application Details
More informationControl Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide
Control Panel ICP-SOL2-P/ICP-SOL3-P en Quick Reference Guide Control Panel Table of Contents en 3 Table of contents 1 Introduction 6 2 Programming 7 2.1 ICON LCD Codepad Programming 7 2.2 TEXT LCD Codepad
More informationPROGRAMMING AND INSTALLATION MANUAL
PROGRAMMING AND INSTALLATION MANUAL Keypad LCD-S (software version 3.10) CA-10 plus GDAŃSK ca10plci_s_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only.
More informationDeveloper s Guide. PC54O1 Serial Interface Module Version 1.0
Developer s Guide PC54O1 Serial Interface Module Version 1.0 IMPORTANT This manual contains information on limitations regarding product use and function and information on the limitations as to liability
More informationUser s Guide English
User s Guide English www.brother.com. Safety Precautions WARNING Follow these guidelines to avoid the risk of fire, burns, injury, electric shocks, rupture, overheating, abnormal odours or smoke. printer
More informationKeypad LCD-L (software version 3.10) CA-10 plus
PROGRAMMING AND INSTALLATION MANUAL Keypad LCD-L (software version 3.10) CA-10 plus GDAŃSK ca10plci_l_e 09/03 WARNING Due to safety reasons, alarm system should be installed by qualified personnel only.
More informationSOFTWARE VERSION 3.10
738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]
More informationSOFTWARE VERSION 3.20
48EPEP-00 SOFTWARE VERSION 3.20 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]
More informationDAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End
RcvrAcct#: Test Date: May, ::PM SYSTEM ENTRY DELAY# [ ] = None, = secs, = secs, = secs, = secs, = secs, = mins [UL installations: The Entry Delay must be set for a maximum of seconds] ENTRY DELAY# [ ]
More informationIntegriti User Manual. Elite / EliteX LCD Terminal Keypads
Integriti User Manual Elite / EliteX LCD Terminal Keypads INNER RANGE recommends that all INTEGRITI systems are installed & maintained by FACTORY CERTIFIED TECHNICIANS. For a list of Accredited Dealers
More informationWireless Alarm System User Guide
Wireless Alarm System User Guide Alarm Panel Time 10:09 c RINS1902 Document SAP: 102015108-03 Contents ProControl+ 4 Setting Devices 5 The Wireless Panel Keypad 5 Wireless Keyfobs 5 Locking the Keyfob
More informationInstruction manual. DAB+/DAB FM Radio DENVER DAB-40. denver-electronics.com
denver-electronics.com Instruction manual DAB+/DAB Radio DENVER DAB-40 COPYRIGHT DENVER ELECTRONICS A/S www.denver-electronics.com www.facebook.com/denverelectronics ENG-1 IMPORTANT SAFETY INFORMATION
More informationProgramming Default Tables
Lynx Plus Control Defaults Lynx Plus Series Installation and Setup Guide *20 Installer code 4112 4112 4112 4112 *21 Quick arm enable 1 1 1 1 *22 Keypad backlight timeout 0 0 0 0 *23 Forced bypass 0 0 0
More informationVisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0
VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 1. Installation Requirements 1.1. PC Pentium III processor or higher. Minimum RAM memory: 128 Mbytes Operating system: Windows XP
More informationUser's Guide. StyleView SV43/44 Primary Drawer ENGLISH. For the latest User Installation Guide please visit: 1/16
User's Guide StyleView SV43/44 Primary Drawer For the latest User Installation Guide please visit: www.ergotron.com User's Guide - English Guía del usuario - Español Manuel de l utilisateur - Français
More informationSecurity System User Guide
Security System User Guide Setting the System: 1. Go to the keypad and key in your access code. (Alternatively, if you have a proximity tag, present your tag to the keypad.) Either - Full Set: 2. Press
More informationUser Manual WatchPower
User Manual WatchPower Management Software for SP Efecto / SP Brilliant (Plus) / SP Initial Table of Contents 1. WatchPower Overview...1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install
More informationAdemco/Protection One 250P1-1 Programming Form
Ademco/Protection One 250P1-1 Programming Form Local programming requires the use of a 2-line Alpha keypad connected to the keypad terminals on the control. Field Function Programmed Values [ ] = Default
More informationInstallation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...
NX-0 RELAY EXPANDER NX-0 OUTPUT EXPANDER Installation Manual GENERAL DESCRIPTION... WIRING INFORMATION FOR NX-0 AND NX-0... NX-0 TERMINAL DESCRIPTION... NX-0 DRAWING... NX-0 TERMINAL DESCRIPTION... NX-0
More informationProperty of Monitronics Inc
Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) Exit
More informationCreated by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8
Quick Start Guide for Interlogix NetworX NX4, NX6 & NX8 Programming Code = 9713 Master User Code=1234 Program Mode= *8 + 9713 To exit programming hit the Exit key until you reach the home screen If this
More informationINT-KSG Keypad Quick user s guide
INT-KSG Keypad Quick user s guide Firmware version 1.02 int-ksg_u_en 01/13 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu WARNINGS Please read
More information9200/9205/9210/9215 Installation and User Guide
9200/9205/9210/9215 Installation and User Guide Compatible Equipment: 9040 Internal Sounder 660 Speech Communicator 9220 Remote Keypad for 9210 and 9215 8506 Eurobell 496324 Issue 1 1 of 10 9200 Family
More informationNX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup
NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series NX-1700E Proximity Card Reader Installation and Startup 2002 GE Interlogix All rights reserved. Printed in the United States of America. These instructions
More informationPCX 46 App User Manual
PCX 46 App User Manual Connect to your home from anywhere in the world. Software version 10 RINS1770-1 Contents PCX46 App - Expandable, App compatible 3 User Friendly Keyfobs (using wireless expander)
More informationACCO SOFT. Configuration program for ACCO NET access control system. User Manual
ACCO SOFT Configuration program for ACCO NET access control system User Manual Program version 1.15.8 acco soft_en 11/17 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu
More informationIDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.
INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-146-01D ISSUED NOVEMBER 2002 VERSION 2.17 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm
More informationCONCEPT 3000/Access 4000 User Manual UK Supplement
CONCEPT 3OOO & Access 4000. 1 CONCEPT 3000/Access 4000 User Manual UK Supplement Revision 5.70 This manual is intended for use in conjunction with the Concept 4000 User Manual, Revision 5.6 or later. CONTENTS
More informationPX/QX/RX Version User Manual. Issue B
PX/QX/RX Version 4.20 User Manual Issue B Contents CONTENTS...2 INTRODUCTION...5 EVENT LOG...5 AREAS & SET GROUPS...5 CIRCUITS...5 USER, SET GROUP AND CIRCUIT IDENTIFICATION...5 USER CODES...6 OPERATOR
More informationDSC PowerSeries Neo Integration
DN2120-1015 DSC PowerSeries Neo Integration The purpose of this application note is to explain how to setup the DSC PowerSeries Neo integration with a KT-400 or a KT-1-M (or PCB) using an RS-232 or IP
More informationINT-KSG Keypad Quick user s guide
INT-KSG Keypad Quick user s guide Firmware version 1.00 int-ksg_u_en 08/10 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu WARNINGS Please read
More informationDAS LCD ALPHA NUMERIC CODEPAD
DAS LCD ALPHA NUMERIC CODEPAD Table of Contents 1. LCD Codepad Diagram... 2 2. Introduction... 3 3. Understanding Your LCD Codepad... 4-7 4. Changing User Codes... 8-9 5. Special Function Keys..... 10
More informationAgility Installation Quick Start Guide 1
Agility Installation Quick Start Guide Thank you for purchasing the Agility Flexible Wireless Solution from RISCO Group. This quick start guide will describe the main steps for installing and programming
More information4140XMPT2 PROGRAMMING FORM
414XMPT2 PROGRAMMING FORM Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown
More informationPowerView. Model PV-101-A, V2.3 User s Guide Section 78
PowerView Model PV-101-A, V2.3 User s Guide 10-18-11 00-02-0795 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications
More informationControl Panels D9412GV4/D7412GV4. en Owner's Manual
Control Panels D9412GV4/D7412GV4 en Owner's Manual Control Panels Table of Contents en 3 Table of contents 1 Introduction 8 1.1 About documentation 9 2 Keypads overview 11 2.1 Identify your keypad style
More informationQUICK CONSUMER REFERENCE GUIDE
QUICK CONSUMER REFERENCE GUIDE YOUR SYSTEM: ADT PM33 Commercial System Starting to use the Alarm Panel and Keypad PM33 Control Panel KP-250 PG2 Keypad Keyfob Setting Your System Step 1 When leaving your
More informationUser Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2
User Manual MPPTracker Management Software for Solar Charge Controller Version: 1.2 Table of Contents 1. MPPTracker Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. MPPTracker Install and Uninstall...
More information3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED
3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP ARMED READY 1 OFF 2 AWAY 3 STAY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY 0 # * NIGHT NO AC AWAY PHONE TEST BYPASS NOT READY ALARM STAY CHIME BAT FIRE CHECK INSTANT
More informationInstallation Instructions
NX-148E-RF LCD Touchpad w/receiver 466-2198 Rev. B May 2005 Product summary The NX-148E-RF Touchpad w/receiver combines touchpad and receiver capabilities into a single device for use with NetworX NX-4,
More informationTHE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13
THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 SECTION I. CHECKING SYSTEM STATUS 3 SECTION II. USING THE MENU 4 SECTION III. ARMING YOUR SECURITY SYSTEM 5 SECTION IV.
More informationAdemco Vista-20SE/First Alert FA-162C Program Sheet
Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) Exit
More informationI-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup
I-NXV-IM Rev F Dec 00 NetworX Series NX-V Control Panel Installation and Setup Copyright Disclaimer Trademarks and patents Copyright 00, GE Security Inc. All rights reserved. This document may not be copied
More informationControl Panels B9512G/B8512G/B6512/B5512/B4512/B3512. en Owner's Manual
Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512 en Owner's Manual Control Panels Table of Contents en 3 Table of contents 1 Introduction 8 1.1 About documentation 9 2 Keypads overview 11 2.1 Identify
More informationINT-GSM. GPRS communication module. Firmware version 1.00 int-gsm_en 07/18
INT-GSM GPRS communication module Firmware version 1.00 int-gsm_en 07/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu IMPORTANT The module should be installed
More informationGPRS Pager 3 INSTALATION AND USER MANUAL
GPRS Pager 3 INSTALATION AND USER MANUAL 1 Table of contents 1 Main functions of the GPRS Pager3...3 2 Operating mode, installation...3 2.1 Installation if no local network is available...3 2.2 Instalation
More informationControl Panel DS7400XiV4-EXP
Control Panel DS7400XiV4-EXP Release Notes January 2005 Release Notes for Firmware Version 4.10 Trademarks Cobox is a trademark of Lantronix. 1.0 Remote Programming Compatibility Use RPS-INT L version
More informationProperty of Monitronics Inc
Enter Program Master Code + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #)
More informationProperty of Monitronics Inc
Enter Program (Locations 034 to 410) 1. Press Program Button on main panel 2. At keypad press 9 + Program Code (9 8 7 6 5) or 1. Power down with black switch on bottom left of panel 2. Power up while holding
More informationXR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors
Name Answer Key Company Address City, State, Zip Instructor Date Your email User Name = Password = XR500/XR100 Command Processor Review 1. may be connected to the LX-Bus. a) Zone expanders c) Output expanders
More informationSPCK420/421 LCD-Keypad for SPC4000/5000/6000. User Manual. Building Technologies. Fire Safety & Security Products
SPCK420/421 LCD-Keypad for SPC4000/5000/6000 User Manual Building Technologies Fire Safety & Security Products Data and design subject to change without notice. / Supply subject to availability. 2008 Copyright
More informationFirst Alert FA160C/162C Installer Notes M. Leuck
First Alert FA160C/162C Installer Notes M. Leuck 1. Programming can only be done by 6139 Alpha keypads, standard 6128 keypad cannot be used to program zones 2. Enter programming: Master Code + 8 + 0 +
More informationSigNET 200/300 User Guide
SigNET 200/300 User Guide Warning: While this system is an advanced design integrated security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system,
More informationInstaller Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE
Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE 1. Programming can only be done with a 6139 Alpha Keypad on Vista-10/20/30PSE models. 2. When entering programming for the first time during Installations
More informationAMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual
AMAX panel AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel 4000 en Operation Manual AMAX panel Table of Contents en 3 Table of contents 1 Safety 5 2 Short information 6 2.1 Introduction
More informationCommercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A
VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security System with Scheduling Programming Guide K0376PRV5 2/11 Rev. A Table of Contents Programming Field Settings for UL864 Compliance
More informationSILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.
S Y S T E M U S E R G U I D E SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM
More informationStart Here. Remove all tape. Locate components
2004 Hewlett-Packard Development Company, L.P. English Arabic Bahasa Português Hrvatski Cesky Dansk Nederland Suomi Français Deutsch Greek Hangul Hebrew Magyar Italiano Español 2004 Hewlett-Packard Development
More informationEVOHD. Programming Guide. Version
EVOHD Programming Guide Version 1.11 www.paradox.com Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on our Web site: www.paradox.com. Your
More informationProperty of Monitronics Inc
Enter Program 1. Master Code + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and
More informationThe Texecom Premier Elite security panels integrate with the g! system using either an Ethernet connection or an RS-232 serial connection.
Manufacturer: Texecom Integration Note Model Number(s): Premier Elite Series Core Module Version: 6.4.200 Comments: Tested with Premier Elite 48 Document Revision Date: 8/6/2013 OVERVIEW AND SUPPORTED
More information