What s New? Spring 2016 Release

Size: px
Start display at page:

Download "What s New? Spring 2016 Release"

Transcription

1 What s New? Spring 2016 Release This document describes the new features available with the software below available on SmartInstaller with the June 2016 release: Important Notes... 2 ECLYPSE Connected Controllers Firmware Version EC-gfxProgram Version ECB BACnet and ECL LONWORKS 50 Series Controllers XpressNetwork Utility Version Xpressgfx Points Version ECLYPSE Selection Tool Version mydc Control Version New! mydc AirBalancing Version Productivity Enhancing Tools Version

2 Important Notes To enhance the security level that the ECLYPSE Series controllers provide, we have implemented an algorithm that requires a password change after a user s first login to the controller. This makes certain that the factory default password is modified for security reasons. Due to this implementation, a password update will be required at the first login attempt of each user, after updating ECLYPSE controllers with firmware version The HTTPS certificate management has been improved. It s recommended to update the ECLYPSE Controllers to the latest firmware version After the update, if the HTTPS controller is used by the controller, you ll need to download the new certificate to the PC in use, using the Export Authority Public Key button in the ECLYPSE Configuration Web Interface under System Settings. Figure 1: Export Authority Public Key To take advantage of the new features offered by the new verison of XpressNetwork Utility available in this release, please update the ECLYPSE controllers firmware to the latest version For the 50 Series Display to function properly after updating the 50 Series ECB and ECL controllers with the latest firmware version (see the ECB BACnet and ECL LONWORKS 50 Series Controllers section for the different controllers firmware versions), the 50 Series Display firmware has to be also updated to the latest firmware version The new Distech Controls Software Compatibility document that includes PC requirements for all Distech Controls software tools, as well as a software intercompatibility table. For more details, refer to this document on SmartSource. 2

3 ECLYPSE Connected Controllers Firmware Version Important Notes To enhance the security level that the ECLYPSE Series controllers provide, we have implemented an algorithm that requires a password change after a user s first login to the controller. This makes certain that the factory default password is modified for security reasons. Due to this implementation, a password update will be required at the first login attempt of each user, after updating ECLYPSE controllers with firmware version The HTTPS certificate management has been improved. It s recommended to update the ECLYPSE Controllers to the latest firmware version After the update, if the HTTPS controller is used by the controller, you ll need to download the new certificate to the PC in use, using the Export Authority Public Key button in the ECLYPSE Configuration Web Interface under System Settings. Figure 2: Export Authority Public Key 3

4 New Features and Enhancements The following new features have been added in this release: Bridge connection in Wi-Fi Client mode: All ECLYPSE Connected Controllers now allow the wireless adapter to be used in Client mode simultaneously with the wired connection. This enables device connectivity through Wired IP to Wi-Fi, and back to a Wired IP network. This option is ideal in situations where passing network wires is impractical, for example to jump an atrium. Wi-Fi Adapter in Access Point mode Wi-Fi Adapter in Client mode Connected to the Wi-Fi Adapter in Access Point mode Wired IP Wired IP Figure 3: Wired IP to Wi-Fi and back to Wired IP network configuration 4

5 The RESTful API is now documented and available at With the RESTful API, the ECLYPSE controllers data can now be accessed from different applications, such as energy dashboards, analytics tools, and mobile applications. The RESTful API documentation explains the implementation protocol for this interface. Figure 4: RESTful API documentation 5

6 xpressenvysion: In addition to the embedded ENVYSION Studio and Viewer, the ECLYPSE Connected System Controller now comes embedded with xpressenvysion. xpressenvysion offers a simplified and streamlined experience in a workflow oriented, drag & drop GUI environment while ENVYSION still offers the full customization features and editing environment. Figure 5: xpressenvysion main page Figure 6: xpressenvysion heat map screen 6

7 RS-485 port settings: The Connected System Controller now supports 2 additional RS-485 ports when connected to an ECY-RS485 module. These port settings are configured in the ECLYPSE Web Configuration Interface when used with BACnet MS/TP devices or in EC-gfxProgram when used with Modbus RTU devices. Figure 7: Multiple RS-485 ports MIMO Technology: ECLYPSE controllers Wi-Fi communication now uses MIMO (multipleinput and multiple-output) technology. This allows wireless communication to reach higher speeds and improve the wireless network s performance. Strong Passwords: ECLYPSE controllers now support configurable strong passwords for login. The password strength level is configurable through the ECLYPSE Configuration Interface. This gives enough flexibility to meet the different security requirements for each site. 7

8 Figure 8: Configurable Strong Password 8

9 EC-gfxProgram Version New Features and Enhancements ECY-303 Support: EC-gfxProgram now supports the ECY-303 Connected Equipment Controller Series. A new menu item under the IO Module folder is now available in the Resource Configuration menu. Figure 9: ECY-303 controller inputs and outputs Configuration 9

10 LCD Screen block in EC-gfxProgram: The LCD Screen block was updated to reflect the new 50 Series controllers and ECx-Display user access settings. Password Type Administrator Manager Operator Guest Points (Points, Overrides, Favorites RW RW No Access No Access List) Schedule RW RW RW No Access Alarms RW RW No Access No Access PID parameters RW R No Access No Access Trends R R R No Access Time / Date RW RW RW R Daylight Saving Time RW RW RW R Language RW RW RW R Device Commissioning: MAC Address, Baud RW R R R Rate, etc. Favorite RW RW Configurable per Favorites group: RW, R or No Access Configurable per Favorites group: RW, R or No Access Export to EDE button in EC-gfxProgram: EC-gfxProgram now features an Export to EDE button, under the Tools tab. This allows users to export the BACnet Objects of the selected programming sheets into an Engineering Data Exchange (EDE) file format, which is a standard format that uses a collection of.csv files to share information about BACnet controllers between vendors. Figure 10: Export to EDE Button in the Tools tab 10

11 Full Project Print: Multiple programming sheets can now be printed in one operation due to the new menu item added to the Print menu. Figure 6: Project Print Window Notification Class block: A new Notification Class block has been added and can be used to make the notification class status and statistical data available for use in the programming logic. For all objects linked to the specified notification class, the block s outputs show the total number of objects that are currently in alarm and whether alarms have been acknowledged or not. This block is available for the ECB and ECY Series controllers. Figure 6: Notification Class block 11

12 AlarmInhibit property: A new AlarmInhibit property has been added to the alarm configuration settings of BACnet objects. This property can be activated either by writing to the AlarmInhibit port that can be available in the BACnet Object block (see figure below) or by selecting an Inhibit binary value from the drop down menu in the alarm configuration (see figure below). This property is available for the ECLYPSE Series controllers. Figure 6: AlarmInhibit port Figure 6: Inhibit binary value drop-down menu RJ Adapter Support: The Subnet Extension block has a new RJ Adaptor configuration to support the RJ9 to RJ45 adaptor that is used to connect a multi-sensor or an EC-Smart- Sense to the subnet port of an ECB, ECL, or ECY Series controllers. 12

13 Figure 11: RJ Adapter block and configuration page in the Resource Configuration Window Weather block: A Weather block is now available in EC-gfxProgram that allows EC-Net AX weather data to be available for use in the programming logic in EC-gfxProgram. For example, the Weather block s Temperature output (outdoor temperature) can be used in the programming logic to better optimize the control of the indoor temperature by taking into account the current outdoor weather conditions. This block is available for ECY and ECB Series controllers. Figure 12: Weather block 13

14 Hide/Show Ports context menu item: the block s context menu now shows a new Show/Hide Ports item that allows the user to show and/or hide ports without having to open the Configure Ports window. With this new context menu item, showing or hiding ports is quicker than ever. Figure 13: Port Visibility contextual menu item 14

15 ECY Series EC-Schedule now supports the Enumeration List Editor allowing to create an enumeration, change the number of members in an enumeration, or change an enumeration member s properties. In addition, for a Boolean schedule, the True Text and False Text fields are now editable. Figure 14: Boolean Type Text Editor window A TriggerTrendLog port is now available for the Generic BACnet objects block. Figure 15: TriggerTrendLog port Bug Fixes The following issues have been fixed in this release: Removed ECx-Light unused reverse action option. Wrong value in the Subnet extension error output port. EC-gfxProgram freezing when the output panel is in floating mode. Erratic ComSensor CO2 value on ECY Series controllers. Error when Override and Set Value actions are triggered on objects newly added to the programming sheet for ECY Series controllers. The Signal Offset parameter of a Hardware Input not taking effect. Signal Offset parameter not available for the Hardware Input of an ECY Series controller. Erratic ComSensor block conversion from ECB to ECY and vice versa. 15

16 ECB Multi State Value and Multi State Input Alarm values configuration not applied correctly. In the Subnet Extension block, the Extension type drop-down menu items have typos. In the Resource Configuration window, ENVYSION Data Tree items have erratic behaviour. When changes are cancelled (by clicking Cancel instead of Ok to the Resource Configuration window), they are still applied to the ENVYSION Data Tree. Snippet conversion issues with the following blocks: Subnet Extension, Wireless Sensor, Light Output, Sunblind Output, Light Sunblind Input. Some parameters change unexpectedly when the Resource Configuration window is reopened after having cancelling (by clicking Cancel) the last modifications. Debug values are not rounded even when Round Debug Values is checked in the Debugging section of the main ribbon. Trend log name of a duplicate object is not correct. Trend log object type is not changed when the Hardware Input type is changed. (T10416) Format contextual menu item still appears even when not relevant. 16

17 ECB BACnet and ECL LONWORKS 50 Series Controllers Important Notes For the 50 Series Display to function properly after updating the 50 Series ECB and ECL controllers with the latest firmware version (see below for the different controllers firmware versions), the 50 Series Display firmware has to be also updated to the latest firmware version New Firmware Versions Controller Series ECB-103 ECB-203 Series ECB-VAV Series ECB-300 Series ECB-400 Series ECB-600 Series Version ECB-PTU Series ECL-103 ECL-203 Series ECL-300 Series ECL-400 Series ECL-600 Series ECL-VAV Series Series Display

18 New Features and Enhancements The following new features have been added in this release: The user access rights were slightly modified to increase security while implementing a more flexible method to provide access rights to items that have been added to the Favorites groups for the Operator and Guest user types. Different rights (Read, Write, or No Access) can be set for each different Favorites group. Figure 16: LCD screen user access configuration 18

19 XpressNetwork Utility Version Important Notes To take advantage of the new features offered by the new verison of XpressNetwork Utility available in this release, please update the ECLYPSE controllers firmware to the latest version New Features and Enhancements The following new features have been added in this release: Parameters Auto-Increment: Some parameters such as the Hostname, Controller Name, Wi-Fi SSID and BACnet Device ID are now auto-incremented to avoid duplicates that can cause communication errors. For example, when configuring the hostname for 10 controllers, and starting with VAV10, the last controller will be VAV20. Figure 17: Hostname auto-increment Referencing to other parameters: For a faster network setup, some parameters can be referenced to the hostname. For example, if the Controller Name parameter of each ECLYPSE controller is the same as its Hostname, the Controller Name parameter can be referenced to the Hostname by entering the following in the Controller Name field: {hostname}. 19

20 Figure 18: Using the hostname as a variable for other parameters Date & Time settings: the date & time settings are now synchronized with the PC using a check box. If the box is checked, the PC current date & time will be sent to the selected controllers. Figure 19: Date & Time synchronization ENVYSION project download: An ENVYSION project can now be downloaded to the ECLYPSE controllers as a.zip file. Unzipping the file is no longer necessary. Figure 20: ENVYSION project file Communicating using HTTPS: The XpressNetwork Utility can now be used even when the ECLYPSE controllers are configured to use the HTTPS protocol. 20

21 Firmware Update progress: During the execution of a firmware update job to one or multiple controllers, a progress report is now available. In addition, it s now possible to cancel the firmware update during execution if needed. Figure 21: ENVYSION project file Bug Fixes The following issues have been fixed in this release: Application freezing when too many jobs are present in the Job History pane. A job still shows as successful even one at least one task has failed. 21

22 Xpressgfx Points Version New Features and Enhancements The following new features have been added in this release: Xpressgfx Points now supports ECY-303 Series controllers. Figure 22: New ECY-303 Controller Bug Fixes The following issues have been fixed in this release: Fixed export to EC-gfxProgram issues on ECY-S1000 Controllers with more than 9 IO modules. Fixed validation issues with NI1000@ C sensors. 22

23 ECLYPSE Selection Tool Version 1.20 New Features and Enhancements The following new features have been added in this release: Addition of the ECY-RS485 to the selection sheet to be considered for the power consumption calculations. Figure 23: ECY-RS485 added to the ECLYPSE Selection Tool 23

24 mydc Control Version New Features and Enhancements The following new features have been added in this release: Support of the Connected Equipment Controller Series (ECY-303). Figure 24: ECY-303 Support 24

25 Support of Com Sensors connected to ECLYPSE devices. Figure 25: Com Sensor Support: Device Extensions and Points 25

26 New! mydc AirBalancing Version mydc AirBalancing is a mobile application that is designed to simplify the task of air balancers by enabling them to perform the Variable Air Volume (VAV) system balancing procedure via their mobile devices. This mobile application works with Distech Controls ECB-VAV Series BACnet Controllers, ECL-VAV Series LONWORKS Controllers, and ECLYPSE Connected VAV Controllers (ECY-VAV series). This app is available for both ANDROID and ios devices and provides convenient and secure access to the VAV controllers connected within an EC-Net AX building automation system. Users can benefit from the following features: VAV Network View: an overall view that displays the status of all the recognized VAV controllers within the network. The VAV network is updated in real-time, giving the user up-todate information at all times. Figure 26: VAV Controller Network 26

27 Simple Calibration: Air balancers can save time by using a simple calibration feature, requiring only the measured airflow value to be entered and the VAV controller adjusts accordingly. All information is synchronized with the BMS instantly through EC-Net AX. Figure 27: Auto-calibration (landscape view) Select Flow Units: Configure flow units for the application between cfm, m 3 /h and L/s. Figure 28: Configuring flow units from Air Balancing View 27

28 Damper Overrides: Perform individual damper override commands on any selected VAV controller(s). Even during the balancing process, override commands will not affect any of the general group commands, making sure that the balancing process is not interrupted unless required. Figure 29: VAV Damper Override within Network (landscape view) Batch Commands: Users can easily perform batch commands during the balancing process, allowing them to save valuable time. Commands, such as Override or Auto can be quickly applied to a batch of selected VAVs located in specific zones in the building. Figure 30: Batch Commands (landscape view) 28

29 Preset Options: Benefit from preset options, such as: Normal Operation, Goto Min Flow, and Full Open that can help save critical time during the balancing process. Figure 31: Preset Options (portrait view) Damper Status Indication: Color-coded indications of each individual VAV damper provides visual information to the user: a) Orange indicates an override from the mydc AirBalancing App; b) Purple indicates an override from EC-Net AX or with a higher priority than the mydc AirBalancing app; c) Green indicates the damper is in normal operation; Figure 32: Damper Override from mydc AirBalancing (landscape view) 29

30 Figure 33: Normal Operation (landscape view) 30

31 Productivity Enhancing Tools Version New Features and Enhancements The following new features have been added in this release: The support of the EC-Smart-Comfort and EC-Smart-Air in all the Preloaded VAV and Pre-engineered VAV Applications for the ECB-VAV Series, ECL-VAV Series, and ECY-VAV series. Refer to the Productivity Enhancing Tools readme file on the Smart- Installer for more details. Updated dcgfxapplications in EC-gfxProgram; o ECB-VAV Series, ECL-VAV Series, ECB-PTU Serie,s and ECL-PTU Series devices are now updated to version 2.5. Updated dcgfxapplication.palette : o ECB-VAV Series, ECL-VAV Series, ECB-PTU Series, and ECL-PTU Series devices are now updated to version

32 New BACnet OptimumStart Custom Block in the HVAC section: Bug Fixes The following issues have been fixed in this release: ECB-PTU Series and ECL-PTU Series: o o o o o o Issue with EC-Smart-Comfort in unoccupied and standby mode. Fan stop delay not working when valve is configured in normally opened position. EC-Smart-Comfort Fan Speed overrides. Fan validation for electric heater when used in cooling mode. Issues when EC-Smart-Comfort sends Value to network in Standby and unoccupied mode. Refer to the Productivity Enhancing Tools readme file on the SmartInstaller for more details about corrected issues for different controller models. 32

ECLYPSE Series Connected IP and Wi-Fi Product Series and Accessories

ECLYPSE Series Connected IP and Wi-Fi Product Series and Accessories S o l u t i o n G u i d e Series IP and Product Series and Accessories Overview The series is a range of connected BACnet/IP controllers and accessories that are used to control a wide range of HVAC equipment

More information

Fall 2015 Release: Now Shipping!

Fall 2015 Release: Now Shipping! Fall 2015 Release: w Shipping! This communication is intended for Distech Controls Partners only. Content cannot be distributed without explicit permission from Distech Controls. For information concerning

More information

Now available to pre-order from Distech Controls

Now available to pre-order from Distech Controls In this release: A Leading Solution for Your Internet of Things Building 3 ECLYPSE Connected Equipment Controllers (ECY-303 Series) 5 Supporting Software for ECLYPSE Connected Equipment Controllers (ECY-303

More information

It s Time You Experienced

It s Time You Experienced It s Time You Experienced ECLYPSE Connected System Controller Series ECLYPSE Connected VAV Controller Series EC-gfxProgram A game-changer! - ThermAir Integrated Technologies Something new in the industry!

More information

ECLYPSE Connected Terminal Unit Controller

ECLYPSE Connected Terminal Unit Controller Datasheet ECLYPSE Connected Terminal Unit Controller Overview The ECLYPSE Connected Terminal Unit Controller is designed to control terminal units such as fan coil units, chilled beams, ceilings, and heat

More information

ECLYPSE Connected Equipment Controller

ECLYPSE Connected Equipment Controller Datasheet ECLYPSE Connected Equipment Controller Overview Features & Benefits The ECLYPSE Connected Equipment Controller (ECY-303) is designed to satisfy the needs of a wide range of HVAC applications

More information

ECLYPSE Connected Terminal Unit Controller

ECLYPSE Connected Terminal Unit Controller Datasheet ECLYPSE Connected Terminal Unit Controller Overview Applications The ECLYPSE Connected Terminal Unit Controller (ECY-(P)TU) is designed to control terminal units such as fan coil units, chilled

More information

Allure EC-Smart-Comfort Series

Allure EC-Smart-Comfort Series Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview The Allure EC-Smart-Comfort series are versatile communicating sensor which provide

More information

ECLYPSE Connected VAV Controller

ECLYPSE Connected VAV Controller Datasheet ECLYPSE Connected VAV Controller Overview Features & Benefits The ECLYPSE Connected VAV Controller (ECY-VAV) is designed to control any variable air volume (VAV) box. It supports BACnet/IP communication

More information

Datasheet. Smart-Sense Room Control. 1/6. Remote Room Control Application for iphone, ipad, and Android devices.

Datasheet. Smart-Sense Room Control.  1/6. Remote Room Control Application for iphone, ipad, and Android devices. Datasheet Smart-Sense Room Room Application for iphone, ipad, and Android devices Overview Applications The Smart-Sense Room application provides precise environmental zone control for temperature, fan

More information

ECLYPSE Connected Terminal Unit Controller

ECLYPSE Connected Terminal Unit Controller Datasheet ECLYPSE Connected Terminal Unit Controller Overview Applications The ECLYPSE Connected Terminal Unit Controller (ECY-TU/PTU) is designed to control terminal units such as fan coil units, chilled

More information

Allure EC-Smart-Comfort Series

Allure EC-Smart-Comfort Series Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview Features & Benefits The Allure EC-Smart-Comfort Series are versatile communicating

More information

Allure EC-Smart-Vue Sensor Series

Allure EC-Smart-Vue Sensor Series H a r d w a r e I n s t a l l a t i o n G u i d e Allure EC-Smart-Vue Sensor Series Figure 1: (Left image) Allure EC Smart Vue, Allure EC Smart Vue-H/-C/-CH sensors. (Right image) Models equipped with

More information

BACnet MS/TP CONTINUE

BACnet MS/TP CONTINUE BACNET MS/TP Topics: 1 Network Requirements 2 Device Addressing 3 Power Supply Requirements 4 System Architecture 5 BACnet Objects & Services 6 Labwork 1 EST: 45:00 BACnet MS/TP 1 Network Requirements

More information

BACnet FF Configuration Wizard Guide

BACnet FF Configuration Wizard Guide BACnet FF Configuration Wizard Guide TABLE OF CONTENTS SYSTEM ENGINEERING GUIDE INTRODUCTION... 3 WEBStation-AX... 3 Features... 3 BACnet FF Configuration Wizard... 3 BACnet FF Configuration Requirement...

More information

Datasheet. BACnet PFC Demo Case. 1/8. Distech Controls BACnet solution demo case. Overview

Datasheet. BACnet PFC Demo Case.  1/8. Distech Controls BACnet solution demo case. Overview Datasheet BACnet PFC Demo Case Distech Controls BACnet solution demo case Overview The BACnet PFC demo case is a simple and plug-and-play tool for qualitative and representative demonstrations aimed at

More information

Lighting and Sunblind Control Solution. Open-to-Wireless TM : Wireless, Battery-less Sensing, Wireless Mesh Networks. Energy Management and Metering

Lighting and Sunblind Control Solution. Open-to-Wireless TM : Wireless, Battery-less Sensing, Wireless Mesh Networks. Energy Management and Metering 0UUV]H[P]L :VS\[PVUZ MVY.YLLULY )\PSKPUNZ;4 Our solutions are built from the ground up to deliver exacting performance meeting the strictest guidelines, achieving an unprecedented interoperable building

More information

ECLYPSE Connected System Controller

ECLYPSE Connected System Controller Datasheet ECLYPSE Connected System Controller Overview Features & Benefits The ECLYPSE Connected System Controller is a modular and scalable platform used to control a wide range of HVAC applications.

More information

System Controls Suggested Specification

System Controls Suggested Specification 1. Description A. Rooftop Unit Controller The Rooftop Unit Controller shall come equipped with a proportional-integral (PI) controller for accurate temperature control. The rooftop unit controller shall

More information

ECLYPSE Connected System Controller

ECLYPSE Connected System Controller Datasheet ECLYPSE Connected System Controller Overview Features & Benefits The ECLYPSE Connected System Controller is a modular and scalable platform used to control a wide range of HVAC applications.

More information

Datasheet. ECB-VAV Series. 1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview

Datasheet. ECB-VAV Series.   1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview Datasheet ECB-VAV Series BACnet B-ASC Single Duct VAV / VVT Controllers Applications Meets the requirements of VAV zone applications, including: Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Parallel

More information

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview Datasheet BACnet B-ASC Powered Terminal Unit Programmable Controllers Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Chilled Beams Reversible Ceiling with

More information

ECLYPSE Connected System Controller

ECLYPSE Connected System Controller ECLYPSE Connected System Controller D a t a s h e e t Overview The ECLYPSE Connected System Controller is a modular and scalable platform that is used to control a wide range of HVAC applications. It supports

More information

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview Datasheet ECB-103 BACnet B-ASC 10-Point Programmable Controller Overview Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Unit Ventilators Chilled Ceilings Improves

More information

ECB-VAVS. Features and Benefits. Applications Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Room Pressurization.

ECB-VAVS. Features and Benefits. Applications Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Room Pressurization. D a t a s h e e t ECB-VAVS Overview The ECB-VAVS controllers are microprocessorbased programmable variable air volume (VAV) controllers designed to control cooling only and cooling with reheat single duct

More information

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

NB-VAV Family Protocol Implementation Conformance Statement (PICS) Vendor Name: American Auto-Matrix Product Name: NB-VAV Family Product Model Number: NB-VAVta, NB-VAVtf, NB-VAVra, NB-VAVrf, NB-VAVr, NB-VAVta-IAQ, NB-VAVtf-IAQ Firmware Revision: 6.03 BACnet Protocol Revision:

More information

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time. Datasheet Shades / Sunblinds Expansion Modules Overview Applications 100-240 VAC shades / sunblinds 24 VDC shades / sunblinds The Expansion Modules are microprocessor-based interfaces that extend the number

More information

Datasheet. ECB-VAV Series. 1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview

Datasheet. ECB-VAV Series.   1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview Datasheet BACnet B-ASC Single Duct VAV / VVT Controllers Overview Applications Meets the requirements of VAV zone applications, including: Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Parallel

More information

ECLYPSE nlight Solution

ECLYPSE nlight Solution Datasheet ECLYPSE nlight Solution nlight protocol Solution for ECLYPSE Connected System Controllers Figure 1: ECLYPSE nlight Solution shown with the power supply module, server module, and nlight communication

More information

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller Technical Specification Sheet Document No. 149-851 August 12, 2011 Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller The Siemens BACnet PTEC Dual Duct Controller provides high

More information

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time. Datasheet Lighting Expansion Modules Overview Applications On/Off lighting 1-10 V dimming lighting The Expansion Modules are microprocessor-based interfaces that extend the number of inputs and outputs

More information

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview Datasheet BACnet B-ASC 10-Point Programmable Controller Overview Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Unit Ventilators Chilled Ceilings Improves

More information

SE7600E Series Application Guide

SE7600E Series Application Guide SE7600E Series Application Guide Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview

More information

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller Technical Specification Sheet Document No. 149-851 September 24, 2014 Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller The Siemens BACnet PTEC Dual Duct Controller provides

More information

Overview. Integrated fail-safe mode in case of communication or power failure to comply with most regulation requirements

Overview. Integrated fail-safe mode in case of communication or power failure to comply with most regulation requirements Datasheet Lighting and Sunblind Expansion Modules Overview Applications When connected to any compatible HVAC programmable controller, the ECx-Light/Blind expansion modules allow to control up to 8 lights

More information

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Datasheet. ECB-PTU Series.  1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview Datasheet BACnet B-ASC Powered Terminal Unit Programmable Controllers Overview Applications Meets the requirements of the following applications: Fan Coil Units Heat Pumps Chilled Beams Reversible Ceiling

More information

htc HTC CONTROLS TEL:

htc HTC CONTROLS TEL: BUILDING AUTOMATION SYSTEM WebControl Quick Reference Guide htc HTC CONTROLS TEL: 46 3 3636 To Launch Open your Internet browser, then type your server s computer name, domain name, or IP address in the

More information

Siemens BACnet Programmable TEC Constant Volume

Siemens BACnet Programmable TEC Constant Volume Technical Specification Sheet Document No. 149-852 September 24, 2014 Siemens BACnet Programmable TEC Constant Volume Returns from power failure without operator intervention. No calibration required,

More information

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features ECP-VAV Series 10-Point Single Duct VAV / VVT Free Programmable Controller Applications Designed to meet the requirements of single duct variable air volume (VAV) or variable volume according to temperature

More information

Zio LCD Wall Modules TR70 AND TR70-H with Sylk bus

Zio LCD Wall Modules TR70 AND TR70-H with Sylk bus Zio LCD Wall Modules TR70 AND TR70-H with Sylk bus OPERATING GUIDE PREFACE This Operating Guide is intended to provide configuration information (using the Niagara Workbench tool) and a general overview

More information

ECLYPSE Connected System

ECLYPSE Connected System Datasheet ECLYPSE Connected System Controller Overview Features & Benefits The ECLYPSE Connected System Controller (ECY-CSC) is a modular and scalable platform used to control a wide range of HVAC applications.

More information

ECB-VAVS and ECB-VAV Series

ECB-VAVS and ECB-VAV Series ECB-VAVS and ECB-VAV Series BACnet B-ASC VAV / VVT Controllers Overview Applications Meets the requirements of single duct VAV zone applications, including: Cooling Only VAV Boxes Cooling with Reheat VAV

More information

BASview 2 USER MANUAL

BASview 2 USER MANUAL BASview 2 USER MANUAL BASview 2 Introduction The BASview2 is a small building controller that can provide alarming, trending, scheduling, graphics and programming for a small facility or portion of a larger

More information

BACnet Terminal Box (VAV) Controller

BACnet Terminal Box (VAV) Controller Technical Specification Sheet May 30, 2012 BACnet Terminal Box (VAV) Controller Figure 1. BACnet Terminal Box Controller. The BACnet Terminal Box Controller (Figure 1) provides high performance Direct

More information

Installation and Operation Instructions

Installation and Operation Instructions 33ZC ComfortID Test and Balance Tool Software Installation and Operation Instructions Part Number 33ZCBAL-SA INSTALLATION The ComfortID Test and Balance Tool software requires no special installation.

More information

BACnet Product Overview

BACnet Product Overview BACnet Product Overview Comfort and energy-saving of a HVAC system are all about control. With networking devices, you can monitor and control your equipment via a communication system anywhere and anytime

More information

Installation Manual. DZK BACnet

Installation Manual. DZK BACnet Installation Manual DZK BACnet InterfacepbilCodarPageNumber TABLE OF CONTENTS Page Overview... 5 Outline and Features... 5 System outline... 5 Specifications and device elements... 6 Functional specifications...

More information

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller Technical Specification Sheet Document No. 149-834 August 23, 2010 Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller The Siemens BACnet PTEC VAV with Series Fan and

More information

UPDATING CONTROLLERS USING PRISM 2 Updating the VCB-X / VCC-X Controller

UPDATING CONTROLLERS USING PRISM 2 Updating the VCB-X / VCC-X Controller Updating the VCB-X / VCC-X Controller Updating the VCB-X / VCC-X Controller Using Prism 2 Version 4.5.0 and higher The VCB-X and VCC-X Controllers are equipped with the ability to update their software

More information

USER S MANUAL. DAS-G01 The Power of Tomorrow

USER S MANUAL. DAS-G01 The Power of Tomorrow USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 0 USER S MANUAL DAS-G01 The Power of Tomorrow Richmond Heights 2018 Page 1 USER'S MANUAL TABLE OF CONTENTS Page # 1.0 GENERAL INFORMATION...

More information

Smart-Sense Room Control. End-User Manual

Smart-Sense Room Control. End-User Manual Smart-Sense Room Control End-User Manual Document Revision History: 1. Version 1.0 February 2012 2. Version 2.0 July 2013 3. Version 2.1 June 2013 Smart-Sense Room Control - User Guide v2.1 05DI-UGSSRCE-21,

More information

Pre-programmed room controller with display and communication

Pre-programmed room controller with display and communication revision 10 2017 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling

More information

Datasheet. ECB-300 Series. 1/6. BACnet B-AAC 18-Point Programmable Controllers. Overview

Datasheet. ECB-300 Series.  1/6. BACnet B-AAC 18-Point Programmable Controllers. Overview Datasheet ECB-300 Series BACnet B-AAC 18-Point Programmable Controllers Overview Applications Meets the requirements of the following applications: Air Handling Units Chillers Boilers Cooling Towers Heat-Exchangers

More information

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller Technical Specification Sheet Document No. 149-831 August 12, 2011 Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller No calibration required, thereby reducing maintenance costs. PID

More information

Shipping Now! Benefit from Unprecedented Adaptability! RCL/RCB-PFC Series Shipping Today!

Shipping Now! Benefit from Unprecedented Adaptability! RCL/RCB-PFC Series Shipping Today! Shipping Notification Document RCL/RCB-PFC Series November, 2012 RCL/RCB-PFC Series Shipping Today! + Shipping Now! Benefit from Unprecedented Adaptability! Inside System Architecture... 3 Benefit from

More information

building performance Reliable Controls Authorized Dealer, LCS Control Systems, completed this project for the Coral Leisure Centre

building performance Reliable Controls Authorized Dealer, LCS Control Systems, completed this project for the Coral Leisure Centre Sustainability standards place a high demand on facility managers to maintain a delicate balance of energy efficiency, client comfort, and environmental impact. The ease of use, versatility, and resilience

More information

Datasheet. ECB-203 Series. 1/6. BACnet B-ASC 14-Point Programmable Controllers. Overview

Datasheet. ECB-203 Series.  1/6. BACnet B-ASC 14-Point Programmable Controllers. Overview Datasheet ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers Overview Applications Meets the requirements of the following applications: Rooftop Units Fan Coil Units Chilled Ceilings Heat Pumps

More information

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

RC-CDTO. Pre-programmed room controller with display, communication and three-point control revision 02 2016 RC-CDTO Pre-programmed room controller with display, communication and three-point control RC-CDTO is a complete pre-programmed room controller from the Regio Midi series intended to control

More information

Overview - Danfoss Link and Connect software versions

Overview - Danfoss Link and Connect software versions Overview - Danfoss Link and Connect software versions Danfoss Link CC Mk II (with minisd card) software 2.1.35 2.3.27 2.4.51 2.5.57 2.7.42 01-12-2010 The initial Danfoss Link CC software: Supports all

More information

Siemens BACnet Programmable TEC Unit Conditioner Controller

Siemens BACnet Programmable TEC Unit Conditioner Controller Technical Specification Sheet Document No. 149-831 September 24, 2014 Siemens BACnet Programmable TEC Unit Conditioner Controller Returns from power failure without operator intervention. No calibration

More information

Efficient. Innovative. Sustainable.

Efficient. Innovative. Sustainable. Efficient. Innovative. Sustainable. Controlesta RCO System Description On-line, at each time, at each place 1 CONTROLESTA RCO System Description 1. System architecture 2.1 Master Controller 2.2 Network

More information

Commercial Controls. Advanced control for saving time and money

Commercial Controls. Advanced control for saving time and money L Connection NetWork Commercial Controls Advanced control for saving time and money The efficient way to control hvac and building operations L Connection Network at a glance: Controls a wide range of

More information

Specification Sheet For electronically commutated motors

Specification Sheet For electronically commutated motors SC-VAV-N Specification Sheet For electronically commutated motors Used in constant pressure applications The SC-EFC is designed to control exhaust air in various building applications. The system includes

More information

Communicative controller for VAV systems

Communicative controller for VAV systems FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration

More information

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control Technical Specification Sheet Document No. 149-844 August 12, 2011 Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control Returns from power failure without operator intervention.

More information

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers Wireless Sensor CARRIER CORPORATION 2017 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-583-01 6/2/2017 Verify that you have the most current version of this

More information

i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building

i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building i-vu Building Automation System VVT Zoning System Total Control and Comfort for Your Building Comfort and Control for Small to Medium Sized Commercial Buildings In the 1990 s, Carrier invented the first

More information

Datasheet. ECB-600 and ECx-400 Series. ECB-600 & ECx-400. Overview. Applications. Features & Benefits.

Datasheet. ECB-600 and ECx-400 Series. ECB-600 & ECx-400. Overview. Applications. Features & Benefits. Datasheet ECB-600 and ECx-400 Series BACnet Programmable Controllers and I/O Extension Modules Overview Applications Meets the requirements of the following applications: Central Plant Air Handling Units

More information

Daikin HVAC Controls Guide Specification

Daikin HVAC Controls Guide Specification VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM Building Management System Integration (Open Protocol Interface) Part 1 - General 1.01. Physical characteristics A. General: The VRV Controls Network shall

More information

SPECIFICATIONS Temperature Setting Range: Ambient Temperature Humidity Display Range: Screen lock & configuration password:

SPECIFICATIONS Temperature Setting Range: Ambient Temperature Humidity Display Range: Screen lock & configuration password: 1 FEATURES 5-inch touch & color screen Humanized operator interface Two kinds of display style Schedule setting in simple way Control your device with your cell-phone Compressor protection 12 wiring connections

More information

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation

More information

Meet the New Standard in Sustainable Buildings

Meet the New Standard in Sustainable Buildings Meet the New Standard in Sustainable Buildings An innovation leader in energy management solutions, Distech Controls provides unique building management technologies and services that optimize energy

More information

Building Management Systems (BMS) Back to Basics. Presented By: Andrew Smith Leader Building Technologies A.G. Coombs Advisory

Building Management Systems (BMS) Back to Basics. Presented By: Andrew Smith Leader Building Technologies A.G. Coombs Advisory Building Management Systems (BMS) Back to Basics Presented By: Andrew Smith Leader Building Technologies A.G. Coombs Advisory Back to Basics. 1) What is a Building Management System (BMS)? 2) Typical Components

More information

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green Richmond Heights Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller Presentation Agenda 1. Introduction To Richmond Heights 2. Smart Universal Controller Features Of DAS-G01 3. DAS-G01

More information

Siemens BACnet VAV Actuator

Siemens BACnet VAV Actuator Technical Specification Sheet Document No. 149-481 May 30, 2012 Siemens BACnet VAV Actuator Setpoints and control parameters assigned and changed locally or remotely. Setpoints and control parameters stored

More information

DataNab it8: Intelligent Communicating Thermostat

DataNab it8: Intelligent Communicating Thermostat DataNab it8: Intelligent Communicating Thermostat CONTENTS: - Title Page (This Page) Page 1 - Description Page 2 - Technical Specs Page 2 - Features Page 2 - Dimensions Page 2 - Installation Page 3 Page

More information

OWNER S MANUAL. Building Gateways MD-CCM08/E (K01-BACNET)

OWNER S MANUAL. Building Gateways MD-CCM08/E (K01-BACNET) OWNER S MANUAL Building Gateways MD-CCM08/E (K01-BACNET) Thank you very much for purchasing our air conditioner, please read this owner's manual carefully before using your air conditioner. CATALOGUE 1.

More information

75F Smart VAV with Reheat

75F Smart VAV with Reheat A unique system-wide approach to maximizing performance PRODUCT OVERVIEW The wireless control solution reduces install cost, improves energy efficiency, and introduces remote control and diagnostic capabilities

More information

ECB-VAV BACnet B-ASC VAV Controller

ECB-VAV BACnet B-ASC VAV Controller D a t a s h e e t ECB-VAV BACnet B-ASC VAV Controller Overview The ECB-VAV Series controllers are microprocessor-based programmable variable air volume (VAV) controllers designed to control any variable

More information

EC-Remote Series. End-User Manual

EC-Remote Series. End-User Manual EC-Remote Series End-User Manual Document Revision History: 1. Version 1.0 February 2012 2. Version 2.0 July 2013 EC-Remote Series - User Guide v2.0 05DI-UGECREM-20, Distech Controls Inc., 2012. All rights

More information

ECLYPSE Communication Modules

ECLYPSE Communication Modules Datasheet ECLYPSE Communication Modules Overview Features & Benefits Communication modules enable ECLYPSE Connected Controllers to communicate with a variety of devices. Scalable and Modular An ECY-RS485

More information

Pre-programmed room controller with display and communication

Pre-programmed room controller with display and communication revision 01 2014 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling

More information

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware

More information

UPDATING CONTROLLERS USING PRISM 2 Updating the VCC-X Controller

UPDATING CONTROLLERS USING PRISM 2 Updating the VCC-X Controller Using Prism 2 7. Click on the icon. The Job-Sites Window will appear. In the Type of CommLink Dialog Box, select CommLink 5 or USB Link II. The VCC-X Controller is equipped with the ability

More information

DESCRIPTION OF MODBUS CONNECTION

DESCRIPTION OF MODBUS CONNECTION DESCRIPTION OF MODBUS CONNECTION MODBUS CONNECTION There is a possibility to control Air Handling Unit (AHU) from external management system (BMS), which work with MODBUS data processing. For MODBUS connection

More information

Building Management Solutions. for Data Centers and Mission Critical Facilities

Building Management Solutions. for Data Centers and Mission Critical Facilities Building Management Solutions for Data Centers and Mission Critical Facilities How Efficient is Your Data Center? Recent years have seen rapid growth in global demand for computing capacity, resulting

More information

FCU-4 FAN COIL CONTROLLER

FCU-4 FAN COIL CONTROLLER FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced

More information

FX Tools Software Package - FX CommPro N2 User s Guide

FX Tools Software Package - FX CommPro N2 User s Guide User s Guide FX CommPro N2 Issue Date September 25, 2008 FX Tools Software Package - FX CommPro N2 User s Guide FX Tools Software Package FX CommPro N2... 3 Introduction...3 Installation... 4 Installing

More information

Honeywell Spyder BACnet Core Competency Training

Honeywell Spyder BACnet Core Competency Training Honeywell Spyder BACnet Core Competency Training 3 Day Training July 10 th -12 th 8:00 AM to 5:00 PM Charles D. Jones North Denver Branch 4900 Osage Street Denver, CO 80221 Class topics include controller

More information

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication X X testregistrierung Control system Type Central BMS interface DCP-FSL II-Stand-alone Pressure independent control valve Straight-way valve Modular, stand-alone room control system, specially for decentralised

More information

ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers

ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers Datasheet ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers Overview Features & Benefits The ECB-203 Series controllers are microprocessor-based programmable controllers designed to control

More information

ECL-VAV LONMARK Certified VAV Controller

ECL-VAV LONMARK Certified VAV Controller D a t a s h e e t ECL-VAV LONMARK Certified VAV Controller Overview The ECL-VAV Series controllers are microprocessor-based programmable variable air volume (VAV) controllers designed to control any variable

More information

ECLYPSE Communication Modules

ECLYPSE Communication Modules Datasheet ECLYPSE Communication Modules Overview Features & Benefits Communication modules enable ECLYPSE Connected Controllers to communicate with a variety of devices. Scalable and Modular An ECY-RS485

More information

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight Liebert icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight LIEBERT icom THERMAL SYSTEM CONTROLS All for One, One for All Optimize a Single Cooling Unit With an Intelligent

More information

Dip Switch settings.

Dip Switch settings. Smart Temp Australia P/L EC 02 Multifunction Module Instruction Manual Ver 1.0 Preface The EC 02 module is a dedicated companion module for exclusive use with the Smart Temp SMT 770 thermostat (firmware

More information

STRA-17 Room controller. Installation and maintenance manual. Content

STRA-17 Room controller. Installation and maintenance manual. Content Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8

More information

Millennium Simplicity Elite Parameter Points and Quirks

Millennium Simplicity Elite Parameter Points and Quirks Millennium Simplicity Elite Parameter Points and Quirks How to access, view and change parameter settings Program Button Test Reset UP Alarms Change Data Address Down 1. Push the Program button once. The

More information

Air-conditioner Network System Centralized Controller AG-150A AG-150A-A GB-50ADA-J

Air-conditioner Network System Centralized Controller AG-150A AG-150A-A GB-50ADA-J Air-conditioner Network System Centralized Controller AG-150A AG-150A-A GB-50ADA-A GB-50ADA-J Instruction Book (Web browser for System maintenance engineer) Contents 1 Introduction...2 1-1 Terms Used in

More information

SE7600E Series Application Guide

SE7600E Series Application Guide Schneider Electric SE7600E Series RTU Controller with IAQ Control Application Guide CONTENTS Solution Overview 2 Product Overview 3 Features & Benefits 3 System Overview & Architecture 4 Models Available

More information

GLAS Smart Thermostat

GLAS Smart Thermostat GLAS Smart Thermostat Product Bulletin SIO-00000, SIO-0000 Code No. LIT-098 Issued August 08 Refer to the QuickLIT website for the most up-to-date version of this document. The GLAS Smart Thermostat is

More information