1 Customer Focus Page 1 of 14 Release of Maxum Workstation Software Patch Versions and Earlier this year as decision was made to reintroduce the Workstation Patch program providing users with quicker updates to serious issues deemed too important to wait for the normal software release schedule. Two Maxum Workstation Software Patch versions have been released since the initial release of version in January In June 2013, the first Workstation Patch version was released to the website followed by Patch release in. All updates for are included in the patch currently on the Siemens website. All changes for these two releases are outlined in the following. For a complete listing of changes, refer to the ReadMe file located on the website mentioned below or refer to ReleaseNotes_5.10.x.pdf located in the /Maxum System Manager/Upgrade 5.10 folder. If you already have Maxum Workstation 5.10.x installed on your PC, select the Maxum GCP Workstation Patch and Embedded Maxum Software and Patches link located at Then install either the _SM_GCP_Update for GCP and System Manager fixes, or the _SM_Only_Update for System Manager fixes only. Note: A new patch will be released in October 2013 for users not currently at Workstation It will include all fixes for Workstation 5.00 and earlier. Description: Update for Gas Chromatograph Portal This update contains the following fixes: 1) Fixed: StatMon ArgumentOutOfRangeException after setting Action to -1 (empty binaries). 2) Allow user to provide an ID for new application On creating a new application in Gas Chromatograph Portal the new application ID was always the highest configured application ID increased by one. In many cases this behavior is not adequate. Now the user can provide a new application ID in the context of Add Application (part of Analyzer Overview ). OLD:

2 Customer Focus Page 2 of 14 NEW: 3) Added: sim_clock was missing required for Timer Applications The flag sim_clock wasn t available in Gas Chromatograph Portal. This flag is important for the configuration of timer applications. This has been added and grouped together with the other two timer application settings: OLD:

3 Customer Focus Page 3 of 14 NEW: 4) Problem: MicroSAM devices of specific database versions (2.07, 3.00, 3.10, 3.20) were not identified properly in the context of upgrading an analyzer. Symptom: An error message was displayed at the beginning of the upgrade process. Resolution: These errors have been fixed. 5) Problem: Windows 7 compatibility issues concerning the FTP file transfer in the context of upgrading an analyzer. Symptom: Timeout and error message when upgrading an analyzer (using Gas Chromatograph Portal Network View) Resolution: The FTP transfer code has been hardened in a way that it will work properly under Windows XP and Windows 7. 6) Problem: The Windows 7 firewall did block important communication between analyzer and workstation in the context of upgrading an analyzer (System Components, BIOS/Loader). Symptom: Gas Chromatograph Portal Network View did fail when attempting to update the BIOS/Loader component. Resolution: Added two inbound firewall rules (port ). 7) Problem: Gas Chromatograph Portal Network View wasn t able to receive broadcast messages from connected analyzers. Symptom: The analyzer status displayed in Gas Chromatograph Portal Network View did miss status information sent by the analyzer. Resolution: Added one inbound firewall rule (port 3004).

4 Customer Focus Page 4 of 14 Notes 1) If the patch is applied, the contained Windows Firewall exception rules are added to the current configuration even if these were not selected previously. If this set of exception rules isn t desired it has to be deselected again after the installation of the patch (available in Control Panel\Programs\Programs and Features, Gas Chromatograph Portal - Context Menu: Change ). 2) Communication with analyzers connected through a Public network interface isn t supported. Therefore it is necessary to have the analyzers connected through an interface which is at least configured as a Domain network or Work network (available in Control Panel/Network and Internet/Network and Sharing Center): Description of Maxum Update Operating System: 1) Problem: Maxum does not always power up with the most recently saved Database. Symptom: Changes made to a Maxum database and restored/saved to flash may not be loaded on the next reset. Resolution: The selection algorithm that determines which Database to load at startup was corrected. 2) Problem: Color Display Touchscreen controller chip on the CIM board does not always hold the touchscreen configuration. Symptom: After a reset, the active touch area may have changed which prevents the user from selecting items on the display correctly. (Other symptoms can be observed also with this problem.) Resolution: The software is updated to support the new controller chip that is being used on the new CIM boards. Database: 1) Problem: Program run did not always work for all remote requests. Symptom: Program run did not work when requested by a Modbus Master. Resolution: Modbus program run fixed. 2) Problem: Modbus readme flags occasionally time out too soon. Symptom: The readme flag will periodically only stay on for a second or two instead of the specific time period. Resolution: Timeout problem corrected to consistently time out at the specified time.

5 Customer Focus Page 5 of 14 HMI: 1) Problem: Alarm text not consistent for in-service and out-of-service messages. Resolution: Text was made consistent between the in/out states. 2) Problem: Pressure Program flow calculator was not working properly. Resolution: Problem corrected. 3) Problem: Times displayed on the HMI were 12 hr format instead of 24 hr. Resolution: Changed the display times to 24 hour clock format. 4) Problem: Alarm text incorrect for alarms Symptom: Text for these alarms came up unknown. Resolution: Fixed alarm text for each alarm to match the alarm numbers. 5) Problem: If timeserver gets set to dhcp, the HMI does not have a way to set it back. Resolution: Modify the HMI display to allow the user to turn off dhcp only if set to 1 on system_setup screen. (If dhcp is not set, the option to control this flag is not visible. This change allows the user to turn off dhcp if set, since dhcp is not a valid Maxum setting.) 6) Problem: Temperature and Pressure screens do not show enough resolution in the number displayed. Symptom: Only one decimal place was visible. Resolution: Increased the number of decimal places on the temperature and pressure screens. 7) Problem: CAN cards cannot be added using the HMI. Symptom: The serial number was being entered/displayed in scientific notation. Resolution: Fixed display/entry of CAN serial number. 8) Problem: Bios version is often incorrect on the system setup screen. Resolution: Remove Bios version from the HMI system setup screen since some versions do not pass this information. DBConverter 1) Problem: MicroSAM databases did not end up with a working serial port configuration following a conversion. Resolution: Add custom conversion for MicroSAM serial settings to leave the original setting format in the system_control table. 2) Problem: After file conversion Results were not tied to their appropriate EUHI. Resolution: Fixed the EUHI reference link with the associated Results. 3) Problem: After a file conversion the date and time values did not always convert to a correct datetime format in the Modbus map. Symptom: The values would not show up in the database even though they were in the map. Resolution: Fixed datetime conversion to handle both DATETIME and separate DATE and TIME entries in the map.

6 Customer Focus Page 6 of 14 Description of Update for GC Portal / GC Network 1) Problem: GCN: MicroSAM update issue Symptom: Flashed MicroSAM (2.8, 3.x) cannot be upgraded with GCP Resolution: Upgrade of flashed MicroSAM (2.8 and 3.x) with GCP 5.10 fixed. 2) Problem: GCP: (Online) Sequence issue with gaps in the sqid field of the sequence_entry table. Symptom: Deleting an entry in the sequence table results in a sequence that will only run to the gap in the analyzer and will then process the first pair in the sequence next. Resolution: With this fix GCP will update the sequence entry index in order to avoid gaps. 3) Problem: GCN/GCP: Confusing states during Data Logger configuration. Symptom: Datalogger cannot handle duplicate or missing serial numbers. Resolution: Both missing and duplicate serial numbers are now handled properly and highlighted. The serial number column highlights these problems for the Data Logger. 4) Problem: Change numbering of group id to make it identical to EZChrom. Symptom: Peak group IDs are automatically defined in GCP to start at one instead of zero and cannot be renumbered. Resolution: Make group ID of each detector start from zero as in EZChrom so that existing result index and MaxBasic programs that rely on this group ID convention can work without modification. 5) Problem: Loading a method from file can produce a duplicate entry. Symptom: Loading a method from file can produce a duplicate entry when overwriting an existing running method. Resolution: Duplicate method entry is prevented by waiting to load the method until the cycle completes. 6) Problem: Remember MBM file path after loading or saving an MBM method. Symptom: Each time a method is saved the directory path has to be retyped. Resolution: The directory path used previously will be the default path the next time a method is saved or loaded. 7) Problem: There is no way to reload a method from source (MBM file/ Ax method). Symptom: After modifying a method, it is not possible to discard the changes and reload the method. Resolution: Added context menus on the method tree node for reloading a method from its source (MBM file or analyzer method). Description of Maxum Update Database: 1) Problem: SNE did not correctly process I/O not on the I2C network that was used as a cycle event. Symptom: A DO designated as a cycle event does not work. Resolution: The SNE message for cycle events was corrected to indicate that the DO control for this I/O was to be done by the Database, rather than the SNE.

7 Customer Focus Page 7 of 14 2) Problem: Automatic parameter lookups for DIs and DOs were incorrect. Symptom: The value passed to the MaxBasic program is incorrect. Resolution: Automatic parameter lookup for DIs and Dos was corrected. 3) Enhancement: Turn off debug messages for DCS writes to modbus map. Symptom: Serial and LogMonitor shows excessive debug messages Resolution: Debug Messages were turned off 4) Problem: PrintService was not always working correctly. Symptom: Printout to serial port or debug port was wrong for standard report logs and reports from MaxBasic. Resolution: Standard report and MaxBasic printing was fixed. 5) Problem: The status on remote I/O is set to normal (0) every 5 minutes to regardless of the actual state. Symptom: Every 5 minutes remote I/O status is set to normal (0) until the remote I/O poll occurs and returns the status to the actual state. Resolution: Change remote I/O failsafe status to not init (-1) rather than normal (0) Fixes interaction with PrintService 6) Problem: If an analyzer has a problem responding correctly to only the currently defined slave address, loading 5.10 does not fix the response to previously defined slave numbers. Symptom: An analyzer that responds to more than one slave address does not correct itself when 5.10 is loaded. Resolution: Fixed typo in check slave mechanism for Modbus so that once is loaded into an analyzer the Modbus slave table is corrected properly by deleting unused slave addresses. 7) Problem: The db_load_file attribute in the system_info table gets set to the last filename saved by the automatic database save function. Symptom: This attribute would rotate between DB0.dat, DB1.dat and DB2.dat. The workstation tools were expecting it to always be the target filename to be used when a database was restored from the workstation. Resolution: Control naming of file when loaded from PC, by making the db_load_file always db.dat. Use cmd_file in system_info for incremental saves 8) Problem: MaxBasic debug statements do not show floating point parameter values. Symptom: MaxBasic debug statements show floating point parameter values as 0 instead of the actual value passed to program execution. Resolution: Changed debug for program execution to properly get the float parameter values 9) Problem: 0-20 ma Analog Outputs can post an alarm that values have been clamped when clamping did not occur. Symptom: Analog Outputs post an alarm when the value is at the low end of the scale even though clamping was not needed and did not take place. (Example: 0 value could generate a clamping alarm. Resolution: I/O values at the low end of the range no longer give an alarm unless clamping really takes place for 0-20 ma outputs.

8 Customer Focus Page 8 of 14 10) Problem: The db_load_file attribute in the system_control table was not always set to point to db.dat. Symptom: After a file conversion the db_load_file attribute was left at its previous setting which could be db0.dat, db1.dat or db2.dat. Resolution: DBConverter was modified to insure that the parameter was set to db.dat after a file conversion. 11) Problem: Parameter Table display of DI and DO values were inconsistent. Symptom: The DI and DO values were displayed as 1. in one case and 1.0 in the other. Resolution: Both DIs and DOs now display as ) Problem: The warning DO state did not always match the state of the Maxum alarm LEDs. Symptom: If a warning alarm occurred and then was cleared, the Warning DO state would remain set. Resolution: The handling of the warning DO specified in the system_control table was fixed to clear when the warning alarms were all cleared. 13) Problem: Pulse DO s do not work correctly with CAN cards. Symptom: A pulse DO using a CAN card address will pulse local Syscon I/O instead. (example: If a pulse DO is set for a CAN card address such as 0: , when the pulse activates it will be seen on DO 0: instead. The CAN node number of 11 in this case is ignored and the local 4.2 address is used.). Resolution: In the above example, 0: will now pulse correctly. HMI 1) Problem: The Workstation HMI does not work for PCs set to some European countries. Symptom: The workstation HMI crashed when opened on a PC that was set for a country that used a, instead of a. for a decimal point. (example: Germany) Resolution: This problem was corrected. 2) Enhancement: Improve the Chinese text in the HMI. (workstation HMI touchscreen version only) Symptom: Chinese translation had many errors in the 5.10 version. Resolution: Chinese translation was improved for the HMI screens and on-line help. (Note: Chinese text for alarms will be improved in a later release.) 3) Problem: The Result and Chromatogram storage had access problems for PCs set to some European countries. Symptom: Once a PC was localized for a country that uses commas in the time/date format the Workstation HMI could not display results or chromatograms. Resolution: This problem was corrected. DBConverter 1) Problem: Fixed db text load of serial_settings table Symptom: When a text file was loaded into an analyzer an invalid entry was created. The result was what appeared to be a blank table in GCP. Resolution: The text file load was corrected to prevent the invalid record.

9 Customer Focus Page 9 of 14 2) Problem: DBConverter was updating the screen text when 4.x files were converted. Symptom: After a conversion some of the buttons would show bad label instead of the correct label. Resolution: DBConverter no longer replaces screen text during 4.x conversions. (To correct a previously converted file you must reconvert the file with the new DBConverter.) 3) Problem: Scaled Modbus values were scaled incorrectly and ended up being transmitted as a zero value. Symptom: The Modbus Host would see zero instead of the correct value. Resolution: Modbus loads were corrected to handle EUHI entries so that they are linked properly to results and calculated the scaled value correctly. Description of Maxum Changes Operating System: 1) Problem: Maxum does not always power up with the most recently saved Database. Symptom: Changes made to a Maxum database and saved to flash may not be loaded on the next reset. Resolution: The selection algorithm that determines which Database to load at startup was corrected. 2) Problem: Networks with frequent errors can result in a LAN driver reset that leaks memory. Symptom: When enough memory is lost, the analyzer can reset. Resolution: Memory leak in this situation was fixed. 3) Problem: Networks with very frequent errors can result in applications not running. Resolution: Error reporting was modified to prevent very frequent errors from blocking applications. Description of Changes for Syscon 2 Database: 1) Problem: SNE did not correctly process I/O not on the I2C network that was used as a cycle event. Symptom: A DO designated as a cycle event does not work. Resolution: The SNE message for cycle events was corrected to indicate that the DO control for this I/O was to be done by the Database, rather than the SNE. 2) Problem: Automatic parameter lookups for DIs and DOs were incorrect. Symptom: The value passed to the MaxBasic program is incorrect. Resolution: Automatic parameter lookup for DIs and Dos was corrected. 3) Enhancement: Turn off debug messages for DCS writes to modbus map Symptom: Serial and LogMonitor shows excessive debug messages Resolution: Debug Messages were turned off

10 Customer Focus Page 10 of 14 4) Problem: The status on remote I/O is set to normal (0) every 5 minutes to regardless of the actual state. Symptom: Every 5 minutes remote I/O status is set to normal (0) until the remote I/O poll occurs and returns the status to the actual state. Resolution: Change remote I/O failsafe status to not init (-1) rather than normal (0) Fixes interaction with PrintService 5) Problem: The db_load_file attribute in the system_info table gets set to the last filename saved by the automatic database save function. Symptom: This attribute would rotate between DB0.dat, DB1.dat and DB2.dat. The workstation tools were expecting it to always be the target filename to be used when a database was restored from the workstation. Resolution: Control naming of file when loaded from PC, by making the db_load_file always db.dat. Use cmd_file in system_info for incremental saves 6) Problem: The db_load_file attribute in the system_control table was not always set to point to db.dat. Symptom: After a file conversion the db_load_file attribute was left at its previous setting which could be db0.dat, db1.dat or db2.dat. Resolution: DBConverter was modified to insure that the parameter was set to db.dat after a file conversion. 7) Problem: Parameter Table display of DI and DO values were inconsistent. Symptom: The DI and DO values were displayed as 1. in one case and 1.0 in the other. Resolution: Both DIs and DOs now display as ) Problem: Pulse DO s do not work correctly with CAN cards. Symptom: A pulse DO using a CAN card address will pulse local Syscon I/O instead. (example: If a pulse DO is set for a CAN card address such as 0: , when the pulse activates it will be seen on DO 0: instead. The CAN node number of 11 in this case is ignored and the local 4.2 address is used.). Resolution: In the above example, 0: will now pulse correctly. DBConverter 1) Problem: Fixed db text load of serial_settings table Symptom: When a text file was loaded into an analyzer an invalid entry was created. The result was what appeared to be a blank table in GCP. Resolution: The text file load was corrected to prevent the invalid record. 2) Problem: DBConverter was updating the screen text when 4.x files were converted. Symptom: After a conversion some of the buttons would show bad label instead of the correct label. Resolution: DBConverter no longer replaces screen text during 4.x conversions. (To correct a previously converted file you must reconvert the file with the new DBConverter.) 3) Problem: Scaled Modbus values were scaled incorrectly and ended up being transmitted as a zero value. Symptom: The Modbus Host would see zero instead of the correct value. Resolution: Modbus loads were corrected to handle EUHI entries so that they are linked properly to results and calculated the scaled value correctly.

11 Maxum Workstation Version numbers Customer Focus Page 11 of 14 Maxum Patch Version Information (Modules updated from original 5.10 CD release are shown in Bold Type) SYSCON: Bootloader version: OS version: DB version: B/W HMI version Touchscreen HMI TEXT version: SNE: OS version: 0004.f16 APP version: 0004.e16 Workstation Software: Gas Chromatograph Portal: EZChrom: System Manager: Touchscreen Workstation HMI: Workstation HMI: Other Software: APC: MaxBasic: SimDis.dll Statmon Printclient DbConverter Formula Note: To verify the correct version for the Workstation, go to Maxum System Manager\Upgrade5.10\versions.txt and verify the versions match above information. To verify the latest version is loaded into the NAU or analyzer, go to the HMI and select Configure Menu => System Setup => Version Info and verify the versions match above information.

12 Customer Focus Page 12 of 14 Maxum Version Information: (With Workstation Patch Release) (Modules updated from original 5.10 CD release are shown in Bold Type) SYSCON: Bootloader version: OS version: DB version: HMI version: SNE: OS version: 0004.f16 APP version: 0004.e16 Workstation Software: EZChrom: System Manager: Touchscreen Workstation HMI: Workstation HMI: Other Software: APC: MaxBasic: SimDis.dll Statmon Printclient DBConverter Note: To verify the correct version for the Workstation, go to Maxum System Manager\Upgrade5.00\versions.txt and verify the versions match above information. To verify the latest version is loaded into the NAU or analyzer, go to the HMI and select Configure Menu => System Setup => Version Info and verify the versions match above information.

13 Customer Focus Page 13 of 14 Maxum 4.40 Version Information: (With Workstation Patch Release) (Modules updated from original 5.10 CD release are shown in Bold Type) SYSCON: BIOS version: (Mar 18, 2005) OS version: V4.4.0 (Oct 2012) DB version: B/W HMI version version for DM Touchscreen HMI TEXT version: SNE: OS version: 0004.f16 APP version: 0004.e16 Workstation Software: EZChrom: System Manager: Touchscreen Workstation HMI: Workstation HMI: Other Software: APC: MaxBasic: SimDis.dll Statmon Printclient DbConverter Note: To verify the correct version for the Workstation, go to Maxum System Manager\Upgrade4.40\versions.txt and verify the versions match above information. To verify the latest version is loaded into the NAU or analyzer, go to the HMI and select Configure Menu => System Setup => Version Info and verify the versions match above information.

14 Customer Focus Page 14 of 14 CD Version Details Maxum Workstation Version (December 2012) Gas Chromatograph Portal 5.10 Maxum System Manager Maxum EZChrom 5.0 Simulated Distillation MaxBasic Editor Maxum OPC Note: System Manager remains at version 5.00 and is NOT able to backup and restore 5.10 databases. GCP is now at version 5.10 and is required to upgrade any Syscon2 to 5.10.

Description: Update for Gas Chromatograph Portal

Description: Update for Gas Chromatograph Portal 1 August 20, 2013 Maxum Workstation 5.10.10 Update Release Notes Requirements Maxum System Manager will operate best on computers equipped with a Pentium-166 or faster CPU, using at least 64 MB RAM. For

More information

The patch (Maxum Workstation Patch for Windows 7 Operating System) will load operating system libraries that Microsoft did not include with Windows

The patch (Maxum Workstation Patch for Windows 7 Operating System) will load operating system libraries that Microsoft did not include with Windows 1 August 20, 2013 Maxum Workstation 5.00.10 Update Release Notes Requirements Maxum System Manager will operate best on computers equipped with a Pentium-166 or faster CPU, using at least 64 MB RAM. For

More information

Summary of 4.10c Patch 3 Changes

Summary of 4.10c Patch 3 Changes MAXUM 4.10c Patch 3 Read the Summary of 4.1c Patch 3 section to determine if you need Patch 3. The Maxum 4.1c Patch 3 Upgrade Procedure section describes how to upgrade your workstation and individual

More information

Maxum Workstation Update Release Notes

Maxum Workstation Update Release Notes 1 August 9, 2017 Maxum Workstation 5.30.01 Update Release Notes Requirements Maxum Workstation Software will operate best on computers equipped with a multi-core processor, with at least 4 GB RAM (8+ GB

More information

1. Fixed problems with lost communication between the Syscon and the SNE that was causing SNE resets

1. Fixed problems with lost communication between the Syscon and the SNE that was causing SNE resets MAXUM 3.2b Patch 3 Read the Summary of 3.2b Patch 3 section to determine if you need Patch 3. The Maxum 3.2b Patch 3 Upgrade Procedure section describes how to upgrade your workstation and individual Maxum

More information

Technical Support Information No. 108c January 2013

Technical Support Information No. 108c January 2013 Customer Focus Page 1 of 17 Maxum/MicroSAM Modbus Transmission Summary In this documentation is a step by step procedure on how to successfully setup the Modbus transmission for the Maxum and/or MicroSAM

More information

Item 1: Microsoft.Net Framework generates an exception when viewing Group calibration information. Known Issues: Gas Chromatograph Portal 5.30.

Item 1: Microsoft.Net Framework generates an exception when viewing Group calibration information. Known Issues: Gas Chromatograph Portal 5.30. The following information covers issues and known work-arounds discovered that can be helpful in working with Maxum Gas Chromatograph Portal version 5.30.00. Known issues that have been discovered are

More information

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2 Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2 Difficulty Level: High Estimated time to execute: 3 Hours Revision

More information

Procedure to Install a CIM Door Retrofit in an Existing Airbath/Airless Maxum II (with SYSCON1/SYSCON+)

Procedure to Install a CIM Door Retrofit in an Existing Airbath/Airless Maxum II (with SYSCON1/SYSCON+) to Install a CIM Door Retrofit in an Existing Airbath/Airless Maxum II (with SYSCON1/SYSCON+) Difficulty Level: Medium Estimated time to execute: 2 Hours Revision History Issue Date Reason 00A 8/18/12

More information

Procedure to Upgrade from SYSCON+ to SYSCON2 and Implement Release 5.0 in a Working Maxum Network Access Unit (NAU)

Procedure to Upgrade from SYSCON+ to SYSCON2 and Implement Release 5.0 in a Working Maxum Network Access Unit (NAU) to Upgrade from SYSCON+ to SYSCON2 and Implement Release 5.0 in a Working Maxum Network Access Unit (NAU) Difficulty Level: High Estimated time to execute: 2 Hours Revision History Issue Date Reason 001

More information

CP30/G30/MC31 Firmware Service Update Version 2993 (19 Aug 2013) Release Notes

CP30/G30/MC31 Firmware Service Update Version 2993 (19 Aug 2013) Release Notes CP30/G30/MC31 Firmware Service Update Version 2993 (19 Aug 2013) Release Notes Summary This package contains updated firmware for the Kingfisher CP30/G30/MC31 modules. Note: This firmware should be used

More information

Procedure to Install a CIM Door Retrofit in an Existing Airbath/Airless Maxum (SYSCON1/SYSCON+ with 5.10 or 5.20 Software)

Procedure to Install a CIM Door Retrofit in an Existing Airbath/Airless Maxum (SYSCON1/SYSCON+ with 5.10 or 5.20 Software) to Install a CIM Door Retrofit in an Existing Airbath/Airless Maxum (SYSCON1/SYSCON+ with 5.10 or 5.20 Software) Difficulty Level: Medium Estimated time to execute: 2 Hours Revision History Issue Date

More information

CP30/G30/MC31 Firmware Version 3100 Known Issues

CP30/G30/MC31 Firmware Version 3100 Known Issues CP30/G30/MC31 Firmware Version 3100 Known Issues Introduction This document lists issues that have been identified with firmware version 3100 for the Kingfisher CP30/G30/MC31 modules. Where possible, workarounds

More information

Procedure to Replace a TCD DPM with an IS TCD DPM in a Maxum or Maxum II Analyzer

Procedure to Replace a TCD DPM with an IS TCD DPM in a Maxum or Maxum II Analyzer Procedure to Replace a TCD DPM with an IS TCD DPM in a Maxum or Maxum II Analyzer Difficulty Level: Medium Estimated time to execute: 1 Hour Revision History Issue Date Reason 001 1/31/2017 Initial Issue

More information

Optichrom Advance Application Personal Computer APC 8.0 & 8.1

Optichrom Advance Application Personal Computer APC 8.0 & 8.1 Siemens Applied Automation Optichrom Advance Application Personal Computer APC 8.0 & 8.1 Contents Overview 1 APC Hardware Installation 1 Addressing the PCI Board 1 PCI Installations Instructions 3 Board

More information

JNIOR Series 3 Release Notes Updated as of Monday, August 29, 2016

JNIOR Series 3 Release Notes Updated as of Monday, August 29, 2016 JNIOR Series 3 Release Notes Updated as of Monday, August 29, 2016 June 14 2016 4.8.614.2124 Fixed an issue where multiple MODBUS connections were violating the MODBUS store synchronization rules and overwriting

More information

Siemens Applied Automation. Advance Maxum MODBUS. Revised Printing April

Siemens Applied Automation. Advance Maxum MODBUS. Revised Printing April Siemens Applied Automation Advance Maxum MODBUS Revised Printing April 2001 User s Guide 2000584-001 2001 by Siemens Applied Automation Bartlesville, Oklahoma 74003, U.S.A. All rights reserved. Copyright

More information

This package contains updated Toolbox PLUS software for configuring and monitoring Kingfisher CP-

This package contains updated Toolbox PLUS software for configuring and monitoring Kingfisher CP- Toolbox PLUS Release Notes Version 4.2.0 (Build 7934, January 18, 2017) Summary This package contains updated Toolbox PLUS software for configuring and monitoring Kingfisher CP- 30 based RTUs. Firmware

More information

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER CHAPTER 6 This chapter helps you identify and solve problems that might occur while you are using the Cisco CDE110. If you are unable to resolve your server problems on your own, contact Cisco Technical

More information

Yokogawa DXP Ethernet Driver Help Kepware Technologies

Yokogawa DXP Ethernet Driver Help Kepware Technologies Yokogawa DXP Ethernet Driver Help 2012 Kepware Technologies 2 Table of Contents Table of Contents 2 3 Overview 3 Device Setup 4 Communications Parameters 6 Optimizing Your Ethernet Communications 8 Data

More information

Cinema.jnior for Series 3 (310/312) Release Notes

Cinema.jnior for Series 3 (310/312) Release Notes Cinema.jnior for Series 3 (310/312) Release Notes Version 2.42.314.1148 3/14/2017 2.41.624.1443 6/24/2016 2.40.925.1320 9/25/2015 2.38.827.1601 8/27/2015 2.37.529.1244 5/29/2015 2.36.420.1232 4/20/2015

More information

PC180 MODBUS COMMUNICATION MANUAL INJECTION MANAGEMENT SYSTEM

PC180 MODBUS COMMUNICATION MANUAL INJECTION MANAGEMENT SYSTEM PC180 MODBUS COMMUNICATION MANUAL INJECTION MANAGEMENT SYSTEM Modbus is a trademark of Modicon, Inc. Manual content copyright 2015 Extreme Telematics Corporation. All Rights Reserved. Ver 3.2 10/07/15

More information

Firmware Revision History and Upgrade Instructions

Firmware Revision History and Upgrade Instructions SENSAPHONE Firmware Revision History and Upgrade Instructions Equipment Firmware: WEB600 v1.46 WEB600 with Relay Output v1.59 Release Date: July 15, 2013 The upgrade package has no prerequisites and supersedes

More information

Release 2.11 Standard AXE Primary Firmware is not intended for use on any 8521 Controller not licensed as a RTU.

Release 2.11 Standard AXE Primary Firmware is not intended for use on any 8521 Controller not licensed as a RTU. December 2010 PAC8000 8521-RT-DE RTU Controller This release consists of firmware release 2.12 for the 8521-RT-DE RTU Controller and DNP Control Package release 2.14. It provides a performance enhancement

More information

Fix serial communications not functioning after reboot when the station number is set to iptables Fix iptables.

Fix serial communications not functioning after reboot when the station number is set to iptables Fix iptables. Sixnet IPm Firmware Revision History Note: IPm firmware versions are of the form major.minor.buildnumber. A letter X will be appended in the case of unreleased experimental versions. Other letters may

More information

ACE Operation Manual

ACE Operation Manual ACE Operation Manual Elecsys Director ACE Operation Manual Product Information Full information about other Elecsys products is available on our website at www.elecsyscorp.com Useful Contact Information

More information

User s Guide 1/2007 MAXUM TM MODBUS. process GAS CHROMATOGRAPHY

User s Guide 1/2007 MAXUM TM MODBUS. process GAS CHROMATOGRAPHY User s Guide 1/2007 MAXUM TM MODBUS process GAS CHROMATOGRAPHY Maxum MODBUS Revised Printing January 2007 User s Guide 2000584-001 Copyright Notice 2002-2007 by Siemens All rights reserved. This publication

More information

CREATING PANEL APPLICATIONS

CREATING PANEL APPLICATIONS CREATING PANEL APPLICATIONS 3.1. Setting up the Panel Application... 1 3.1.1. General Settings...2 3.1.2. Custom Settings...5 3.1.3. Activating Multiple Overlapped Buttons by One Touch...7 3.1.4. Specifying

More information

VR18 FAQs - Frequently Asked Questions

VR18 FAQs - Frequently Asked Questions VR18 FAQs - Frequently Asked Questions Q1: What is the maximum scale low and scale high values we can set in the recorder for the analog inputs and outputs? Q2: What is the maximum distance between PC

More information

VisionTools Pro-e v6.1

VisionTools Pro-e v6.1 Page 1 of 11 VisionTools Pro-e v6.1 I. VisionTools Pro-e version history II. Introduction to VisionTools Pro-e III. Regarding the use of foreign-language characters IV. PC requirements and recommendations

More information

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08 Model IR4000M HART Field Device Specification Multi-Point Monitor The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

jfqbi= = eqji=qççäâáí= = = eqji=^ééäáå~íáçå=réäç~çéê== rëéê=dìáçé= oéäé~ëé=oko=

jfqbi= = eqji=qççäâáí= = = eqji=^ééäáå~íáçå=réäç~çéê== rëéê=dìáçé= oéäé~ëé=oko= jfqbi= = eqji=qççäâáí= = = eqji=^ééäáå~íáçå=réäç~çéê== rëéê=dìáçé= oéäé~ëé=oko= oéäé~ëé=oko = HTML Application Uploader User Guide NOTICE The information contained in this document is believed to be accurate

More information

Fisher ROC Plus Serial Driver Help Kepware, Inc.

Fisher ROC Plus Serial Driver Help Kepware, Inc. Fisher ROC Plus Serial Driver Help 2015 Kepware, Inc. 2 Table of Contents Table of Contents 2 5 Overview 5 Channel Setup 7 Device Setup 13 Scan Mode 15 Timings and Timeouts 16 Automatic Demotion 17 Automatic

More information

New Service Release Advisor Management Software: SP7

New Service Release Advisor Management Software: SP7 New Service Release Advisor Management Software: SP7 New Features 33144 - Added card details also to the search when the card deck is being searched 32918 - Monitor - Allowing to define keyboard shortcuts

More information

ASIC/2 Firmware Release Note

ASIC/2 Firmware Release Note ASIC/2 Firmware Release Note APPLIES TO ASIC/2-7540, ASIC/2-8540 LAST REVISED 2007-03-26 ASIC/2-7540 FW754a2.1 (2007-03-23) ASIC/2-8540 FW854a2.1 (2007-03-26) Adds Decimal Fraction value to Function Float-to-Integer

More information

Model 2000 Programmer EnSonic Display & Control Unit. Document code: M2KCNF.001

Model 2000 Programmer EnSonic Display & Control Unit. Document code: M2KCNF.001 Model 2000 Programmer EnSonic Display & Control Unit Document code: 10735.M2KCNF.001 Document Model 2000 Programmer: EnSonic Display & Control Unit Document code 10735.M2KCNF.001 Date January 25, 2004

More information

Scan Station 710/730 Release Notes:

Scan Station 710/730 Release Notes: Scan Station 710/730 Release Notes: Date: March 26, 2018 New features and updates for the Scan Station software release V1.03.67 from V1.03.65 and Remote Administration software release V1.03.42 (no update

More information

GRANDSTREAM NETWORKS SUMMARY OF UPDATES. The main purpose of this release is bug fixes and feature enhancement.

GRANDSTREAM NETWORKS SUMMARY OF UPDATES. The main purpose of this release is bug fixes and feature enhancement. GRANDSTREAM NETWORKS Firmware Release Notes: Version 1.0.2.21 (HW Supported: 1.2A, 1.3A, 1.3B, 1.5A, 1.6A) Date: August 31, 2017 The main purpose of this release is bug fixes and feature enhancement. CHANGES

More information

Orchestrator. Version Release Information. Version 4.0 of the Orchestrator Software has now been released.

Orchestrator. Version Release Information. Version 4.0 of the Orchestrator Software has now been released. Orchestrator Version 4.0.0 Release Information Version 4.0 of the Orchestrator Software has now been released. Version 4.0 contains the following fixes/changes from V3.3 Operating System: Supports Windows

More information

Fisher ROC Plus Serial Driver Help Kepware Technologies

Fisher ROC Plus Serial Driver Help Kepware Technologies Fisher ROC Plus Serial Driver Help 2014 Kepware Technologies 2 Table of Contents Table of Contents 2 5 Overview 5 Channel Setup 6 Device Setup 7 Tag Import Settings 7 Address Specification 8 Operator Identification

More information

Fisher ROC Plus Ethernet Driver Help Kepware, Inc.

Fisher ROC Plus Ethernet Driver Help Kepware, Inc. Fisher ROC Plus Ethernet Driver Help 2015 Kepware, Inc. 2 Table of Contents Table of Contents 2 5 Overview 5 Channel Setup 7 Device Setup 13 Scan Mode 15 Timings and Timeouts 16 Automatic Demotion 17 Automatic

More information

Allegro CX Field PC Release 1.07a

Allegro CX Field PC Release 1.07a Allegro CX Field PC Release 1.07a Installation Instructions June 2007 Enhancements Enhancements included in the Allegro CX Field PC operating system release 1.07a are as follows: Integration of the OS

More information

StarFinder. Operation Manual. Star Chromatography Workstation Version 6

StarFinder. Operation Manual. Star Chromatography Workstation Version 6 Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Star Chromatography Workstation Version 6 StarFinder Operation Manual Varian, Inc. 2002 03-914723-00:Rev. 2 Trademark Acknowledgment

More information

NORDSON CORPORATION AMHERST, OHIO USA

NORDSON CORPORATION AMHERST, OHIO USA CanWorks Operator Interface Tracking PLUS for CanWorks Systems with SM-2 Spray Monitors User Guide Part 1018132A NORDSON CORPORATION AMHERST, OHIO USA 2002 Nordson Corporation. All rights reserved. CanWorks,

More information

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System SIMATIC HMI WinCC V7.0 SP1 SIMATIC HMI WinCC V7.0 SP1 WinCC Alarm Logging 1 Message System in WinCC 2 Principles of the Message System 3 Configuring the Message System 4 Printout of the Online Help 11/2008

More information

On Control SUSA v1.1 MODBUS Functions

On Control SUSA v1.1 MODBUS Functions Summary of functions: Function code 0x03 Read holding registers and Function code 0x04 Read input registers (both functon codes are equivalent): Register address: 0x0000..0x0102 (0..258) 0x0200..0x0281

More information

Technical Support Information No January Complementary Service Information for MicroSAM Part 4

Technical Support Information No January Complementary Service Information for MicroSAM Part 4 Process Analytics USA Customer Focus Page 1 of 7 Complementary Service Information for MicroSAM Part 4 According to the increasing number of MicroSAM applications and the experience resulting from it,

More information

Supply voltage. Input current. Encoder supply. Memory

Supply voltage. Input current. Encoder supply. Memory Data sheet SIMATIC S7-200, CPU 224XP COMPACT UNIT, DC POWER SUPPLY 14 DI DC/10 DO DC, 2 AI, 1 AO 12/16 KB CODE/10 KB DATA, 2 PPI/FREEPORT PORTS Supply voltage Rated value (DC) 24 V DC Load voltage L+ Rated

More information

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA, Data sheet SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA, Supply voltage Rated value (DC) 24 V DC Load voltage L+ Rated value (DC) permissible range, lower

More information

Superview INSTRUCTIONS. Version 2.0x

Superview INSTRUCTIONS. Version 2.0x INSTRUCTIONS Version 2.0x INDEX INDEX... 1 INTRODUCTION... 2 INSTALLING SUPERVIEW... 3 SYSTEM REQUIREMENTS... 3 INSTALLATION PROCEDURES... 3 FIRST STEPS... 4 CREATING A SIMPLE APPLICATION... 4 Start...

More information

IntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng

IntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng IntesisBox MAPS Configuration & monitoring software of IntesisBox KNX series User's manual Issue Date: 06/17 r1.0 eng Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject

More information

SCADA. SurvalentONE. STC Explorer

SCADA. SurvalentONE. STC Explorer SurvalentONE SCADA SurvalentONE SCADA Survalent SCADA is a software automation solution to provide real-time control and data acquisition for utility operations. Survalent SCADA software includes STC Explorer

More information

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer Difficulty Level: Medium Estimated time to execute: 1 Hour Revision History Issue Date Reason 001 5/31/2016 Initial

More information

Yokogawa HR Driver PTC Inc. All Rights Reserved.

Yokogawa HR Driver PTC Inc. All Rights Reserved. 2017 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 3 Overview 3 Setup 4 Channel Properties - General 4 Channel Properties - Serial Communications 5 Channel Properties - Write

More information

Safe Mode: Solve Startup Problems & Crashes S 3/1. Solve (Almost) Any Problem Your Computer May Have

Safe Mode: Solve Startup Problems & Crashes S 3/1. Solve (Almost) Any Problem Your Computer May Have Safe Mode: Solve Startup Problems & Crashes S 3/1 Solve (Almost) Any Problem Your Computer May Have If your PC refuses to start or keeps crashing for some unknown reason, Safe Mode is often your last resort.

More information

Operator Manual for Profibus

Operator Manual for Profibus PROCESS ANALYSERS SERVOPRO MultiExact Operator Manual for Profibus Part Number: Revision: Language: 05410007A 0 UK English This page intentionally blank LIST OF CONTENTS Section Page 1. DESCRIPTION AND

More information

Release Notes Schroff Firmware Part Number 99-W D For the 6-Slot Zephyr Chassis Fan Tray

Release Notes Schroff Firmware Part Number 99-W D For the 6-Slot Zephyr Chassis Fan Tray s Schroff Firmware Part Number 99-W0005011D For the 6-Slot Zephyr Chassis Fan Tray Release Date: December x, 2008 Release History: Release Date Schroff Version PPS version June 28, 2007 Revision A V1.51

More information

Error code. Description of the circumstances under which the problem occurred. Less than 200. Linux system call error.

Error code. Description of the circumstances under which the problem occurred. Less than 200. Linux system call error. Error code Less than 200 Error code Error type Description of the circumstances under which the problem occurred Linux system call error. Explanation of possible causes Countermeasures 1001 CM_NO_MEMORY

More information

Yokogawa HR Driver PTC Inc. All Rights Reserved.

Yokogawa HR Driver PTC Inc. All Rights Reserved. 2016 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 3 Overview 3 Device Setup 4 Data Types Description 6 Address Descriptions 7 HR2400 (10CH) Addressing 7 HR2400 (20CH) Addressing

More information

-Page 1 of 21 -

-Page 1 of 21 - ATCA Tester Version 3.3.0 Release Notes -Page 1 of 21 - Introduction The ATCA Tester is an automated test suite for testing the platform management software in different types of ATCA building blocks,

More information

JNIOR Support Tool Release Notes

JNIOR Support Tool Release Notes JNIOR Support Tool Release Notes Version 7.5.518.1209 18 May 2018 7.4.417.1208 17 April 2018 7.4.410.1512 10 April 2018 RELEASED to the website May 25, 2018 NOTE: This version or later IS REQUIRED with

More information

Modbus Plus Driver PTC Inc. All Rights Reserved.

Modbus Plus Driver PTC Inc. All Rights Reserved. 2017 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 4 Overview 5 External Dependencies 5 Setup 6 Channel Properties 7 Channel Properties General 7 Channel Properties Write Optimizations

More information

Modbus ASCII Serial Device Driver Help 2009 Kepware Technologies

Modbus ASCII Serial Device Driver Help 2009 Kepware Technologies Modbus ASCII Serial Device Driver Help 2009 Kepware Technologies 1 Table of Contents 1 Getting Started... 3 Help Contents... 3 Overview... 3 2 Device Setup... 3 Device Setup... 3 Cable Diagram... 4 Modem

More information

User Guide PC tool GDIR.danfoss.com

User Guide PC tool GDIR.danfoss.com User Guide PC tool Software for addressing, calibration and parameterization of Basic, Premium and Heavy Duty gas detection units and gas detection controller configuration GDIR.danfoss.com Contents Page

More information

Release 2.11 Standard AXE Primary Firmware is not intended for use on any 8521 Controller not licensed as a RTU.

Release 2.11 Standard AXE Primary Firmware is not intended for use on any 8521 Controller not licensed as a RTU. GFK-2594 September 2010 PAC8000 8521-RT-DE RTU Controller Firmware release 2.11 for the 8521-RT-DE RTU Controller adds DNP3 protocol support with store and forward capability. For details, see New Features

More information

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide VxI Power Ltd. IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide 01/12/2015 Document Number: 14970-020A Issue Number: 2 Contents 1.0 Device Overview... 2 2.0 Getting Started... 3 2.1 Connecting the Device...

More information

EasyIO 30P Frequently Asked Questions. Frequently Asked Questions

EasyIO 30P Frequently Asked Questions. Frequently Asked Questions Frequently Asked Questions 1 Document Change Log 31 th January 2011 Document created. 07 th March 2012 Remove Non Sedona content Update documents name 2 Disclaimer EasyIO 30P is a product by EasyIO Corporation

More information

Firmware Release Notes PREMIUM ETYPORT EXEC V5.4 TSX P M TSX P M TSX P M

Firmware Release Notes PREMIUM ETYPORT EXEC V5.4 TSX P M TSX P M TSX P M Status: Official Doc. No.: S1A5907607 Revision: 04 Firmware Release Notes PREMIUM ETYPORT EXEC V5.4 TSX P57 1634M TSX P57 2634M TSX P57 3634M Affected Product (s) Prior Version (s) New Version (s) Date

More information

Conversion checklist from BusinessWorks Version 12 to Sage BusinessWorks 2017

Conversion checklist from BusinessWorks Version 12 to Sage BusinessWorks 2017 Conversion checklist from BusinessWorks Version 12 to Sage BusinessWorks 2017 This checklist includes instructions for how to convert from BusinessWorks Version 12 to a new installation of Sage BusinessWorks

More information

VIP-102B IP Solutions Setup Tool Reference Manual

VIP-102B IP Solutions Setup Tool Reference Manual VIP-102B IP Solutions Setup Tool Reference Manual Version 6.3.0.0 For latest updates to this manual please check our website at: http://www.valcom.com/vipsetuptool/default.htm then click on Reference Manual

More information

Device Quotas. Administrator's Guide

Device Quotas. Administrator's Guide Device Quotas Administrator's Guide March 2015 www.lexmark.com Contents 2 Contents Overview... 4 Default configuration...4 Before you begin... 4 Configuring the application from the control panel...6 Accessing

More information

8-1. This chapter explains how to set and use Data Sampling.

8-1. This chapter explains how to set and use Data Sampling. 8-1 8. Data Sampling This chapter explains how to set and use Data Sampling. 8.1. Overview... 8-2 8.2. Data Sampling Management... 8-2 8.3. Creating a New Data Sampling... 8-2 8.4. Synchronizing cmt Viewer

More information

Chapter A1: Setting up BankLink Practice, BankLink Notes and BankLink Notes Online

Chapter A1: Setting up BankLink Practice, BankLink Notes and BankLink Notes Online Chapter A1: Setting up BankLink Practice, BankLink Notes and BankLink Notes Online This chapter is aimed at BankLink Administrators This chapter covers setting up BankLink Practice and BankLink Notes Online

More information

Perceptive AP Invoice eform

Perceptive AP Invoice eform Perceptive Release Notes Version: 12.2.x Written by: Product Documentation, R&D Date: August 2016 2015 Perceptive Software. All rights reserved Perceptive Software is a trademark of Lexmark International

More information

VERTIV. Albér Battery Xplorer Enterprise (BXE) Software Release Notes VERSION 4.5 (RELEASE NOTES VERSION 11), APRIL 6, 2018

VERTIV. Albér Battery Xplorer Enterprise (BXE) Software Release Notes VERSION 4.5 (RELEASE NOTES VERSION 11), APRIL 6, 2018 VERTIV Albér Battery Xplorer Enterprise (BXE) Software Release Notes VERSION 4.5 (RELEASE NOTES VERSION 11), APRIL 6, 2018 Release Notes Section Outline 1 Updates for This Release (Version 4.5) 2 Version

More information

Download Software User Guide Software Version

Download Software User Guide Software Version Download Software User Guide Software Version 1.3.51 AMALGAMATED INSTRUMENT CO PTY LTD ACN: 001 589 439 Unit 5, 28 Leighton Place Hornsby Telephone: +61 2 9476 2244 e-mail: sales@aicpl.com.au NSW 2077

More information

IMPORTANT PRODUCT INFORMATION

IMPORTANT PRODUCT INFORMATION 22-Apr-08 IMPORTANT PRODUCT INFORMATION READ THIS INFORMATION FIRST Product: Max-ON Hot-Backup Redundancy Software, Release 2.05 Introduction Max-ON is a trademark of GE Fanuc Automation, Inc. IC641HBR300D

More information

VISU+ BEST PRACTICE. Tips for using the Visu+ software. Application note 8212_en_01. 1 Description

VISU+ BEST PRACTICE. Tips for using the Visu+ software. Application note 8212_en_01. 1 Description Tips for using the Visu+ software Application note 8212_en_01 PHOENIX CONTACT 2013-10-21 1 Description This document provides support in finding the optimum hardware platform (Windows PC with Win32 or

More information

LxT Version October LxT Version December LxT Version January 2014

LxT Version October LxT Version December LxT Version January 2014 SoundTrack LXT & SoundExpert LxT Release History Enhancements and Fixes for SoundTrack LxT and SoundExpert LxT Firmware 1 LxT Version 2302 October 2017 Corrected calculation for Under-Range Value was lower

More information

Wago Ethernet Driver Help Kepware Technologies

Wago Ethernet Driver Help Kepware Technologies 1 Kepware Technologies Table of Contents Table of Contents 4 Overview 4 Device Setup 5 P/IP 5 Block Sizes 5 Slot Configuration 7 Digital Input Modules 7 Digital Output Modules 8 Analog Input Modules 9

More information

Kaseya 2. User Guide. for VSA 6.0

Kaseya 2. User Guide. for VSA 6.0 Kaseya 2 Patch Management User Guide for VSA 6.0 July 19, 2010 About Kaseya Kaseya is a global provider of IT automation software for IT Solution Providers and Public and Private Sector IT organizations.

More information

Release Notes Schroff Firmware Part Number Intelligent Shelf Alarm Panel (ISAP-II)

Release Notes Schroff Firmware Part Number Intelligent Shelf Alarm Panel (ISAP-II) s Schroff Firmware Part Number 63998-10151 Intelligent Shelf Alarm Panel (ISAP-II) Release Date: August 27, 2009 Release History: Release Date Schroff Version PPS version August 27, 2009 Revision 51, Build

More information

Security Escort Central Console Software. Table of Contents. Release Notes. Security Systems

Security Escort Central Console Software. Table of Contents. Release Notes. Security Systems Release Notes Security Escort Central Console Software Table of Contents 1 Security Escort v3.0.1... 2 1.1 Enhancements... 2 1.2 Errors Fixed... 2 1.3 Known Limitations and Restrictions... 3 1.4 Important

More information

TCweb Data Logger. November 9, 2005 Rev D Tidal Engineering Corporation Page 1 of 30

TCweb Data Logger. November 9, 2005 Rev D Tidal Engineering Corporation Page 1 of 30 TCweb Data Logger Page 1 of 30 Overview...3 Features...4 General...4 Tree View...4 Logging...4 Graphing...4 DDE...4 OPC...4 Alarms (Full Version)...4 Specifications...5 Table 1: TCweb Specifications...5

More information

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05 WRTU Client User Manual Date: 29 May, 2014 Document Revision: 1.05 2014 by BiPOM Electronics, Inc. All rights reserved. WRTU Client User Manual. No part of this work may be reproduced in any manner without

More information

Description of the Simotion D4xx Firmware update

Description of the Simotion D4xx Firmware update Description of the Simotion D4 Firmware update Simotion D consists of several individual software components that can be updated separately. The following figure shows the individual software components

More information

Ledger 9.0D ( )

Ledger 9.0D ( ) Adagio Ledger 9.0D (2011.10.17) Release Notes The most up-to-date compatibility information is on the Product Compatibility Info link at www.softrak.com. Upgrade Complexity From prior version: Easy Adagio

More information

Fisher ROC Serial Driver Help Kepware Technologies

Fisher ROC Serial Driver Help Kepware Technologies Fisher ROC Serial Driver Help 2012 Kepware Technologies 2 Table of Contents Table of Contents 2 4 Overview 4 Channel Setup 5 Device Setup 6 Tag Import Settings 6 Address Specification 7 Operator Identification

More information

Kaseya 2. User Guide. for VSA 6.2

Kaseya 2. User Guide. for VSA 6.2 Kaseya 2 Audit User Guide for VSA 6.2 April 16, 2012 About Kaseya Kaseya is a global provider of IT automation software for IT Solution Providers and Public and Private Sector IT organizations. Kaseya's

More information

Mettler Toledo Driver PTC Inc. All Rights Reserved.

Mettler Toledo Driver PTC Inc. All Rights Reserved. 2017 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 3 Overview 3 Setup 4 Channel Properties General 5 Channel Properties Serial Communications 6 Channel Properties Write Optimizations

More information

Memory may be insufficient. Memory may be insufficient.

Memory may be insufficient. Memory may be insufficient. Error code Less than 200 Error code Error type Description of the circumstances under which the problem occurred Linux system call error. Explanation of possible causes Countermeasures 1001 CM_NO_MEMORY

More information

Avigilon Control Center 5.6 Release Notes

Avigilon Control Center 5.6 Release Notes Notes Version 5.6.0.18 Released Tuesday July 7 th, 2015 Release Summary This is the first scheduled service release for Avigilon Control Center 5.6. Users experiencing issues listed in the Issues Fixed

More information

DNP3 Master Ethernet Driver PTC Inc. All Rights Reserved.

DNP3 Master Ethernet Driver PTC Inc. All Rights Reserved. 2018 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 10 Overview 10 Setup 11 Channel Properties General 11 Channel Properties Ethernet Communications 12 Channel Properties Write

More information

EZChrom Elite Compact. What s New in EZChrom Elite Compact Service Pack 2

EZChrom Elite Compact. What s New in EZChrom Elite Compact Service Pack 2 EZChrom Elite Compact What s New in EZChrom Elite Compact 3.3.2 Service Pack 2 Notices Agilent Technologies, Inc. 2010 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Golander Peristaltic Pump MODBUS Communication Instruction

Golander Peristaltic Pump MODBUS Communication Instruction Golander Peristaltic Pump MODBUS Communication Instruction 1 Introduction... 1 2 Modbus Protocol... 2 2.1 Modbus Protocol Model... 2 2.2 Byte Format... 2 2.3 MODBUS Message Timing... 2 2.4 Field... 3 2.5

More information

Operation Manual. for the. Data Logging Software. Version 7.1. (Isoft.xls)

Operation Manual. for the. Data Logging Software. Version 7.1. (Isoft.xls) for the Data Logging Software Version 7.1 (Isoft.xls) TetraTec Instruments GmbH 1 GENERAL HINTS 1.1 Typographical Conventions Displayment Means marks a work procedure, which you must implement references

More information

1 CDR-882 v2.00 Firmware... 3

1 CDR-882 v2.00 Firmware... 3 v2.00 User Manual Addendum March 2009 Contents 1 CDR-882 v2.00 Firmware... 3 1.1 Summary... 3 1.1.1 Firmware upgrade... 3 1.2 Independent recording on both drives... 3 1.3 Zero overlap DiscSpan... 4 1.4

More information

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual The Ferguson Beauregard RTU-5000 Configurator program and manuals are Copyright 1997-2004 by

More information

InfraStruXure Central Release Notes

InfraStruXure Central Release Notes InfraStruXure Central 5.0.1 Release Notes Table of Contents: Part Numbers Affected.......1 Minimum System Requirements......1 New Features........1 Issues Fixed.......2 Known Issues......3 Upgrade Procedure......10

More information

IMPORTANT UPGRADING NOTE

IMPORTANT UPGRADING NOTE GRANDSTREAM NETWORKS Firmware Release Notes: Version 1.0.2.9 (HW Supported: 1.2A, 1.3A, 1.3B, 1.5A, 1.6A) Date: June 1 st, 2017 IMPORTANT UPGRADING NOTE Once upgraded to 1.0.2.x firmware, downgrading to

More information