MULTI-ATLAS-BASED SEGMENTATION OF PELVIC STRUCTURES FROM CT SCANS FOR PLANNING IN PROSTATE CANCER RADIOTHERAPY

Size: px
Start display at page:

Download "MULTI-ATLAS-BASED SEGMENTATION OF PELVIC STRUCTURES FROM CT SCANS FOR PLANNING IN PROSTATE CANCER RADIOTHERAPY"

Transcription

1 MULTI-ATLAS-BASED SEGMENTATION OF PELVIC STRUCTURES FROM CT SCANS FOR PLANNING IN PROSTATE CANCER RADIOTHERAPY Oscar Acosta, Jason Dowling, Gael Drean, Antoine Simon, Renaud De Crevoisier, Pascal Haigron To cite this version: Oscar Acosta, Jason Dowling, Gael Drean, Antoine Simon, Renaud De Crevoisier, et al.. MULTI-ATLAS-BASED SEGMENTATION OF PELVIC STRUCTURES FROM CT SCANS FOR PLANNING IN PROSTATE CANCER RADIOTHERAPY. Ayman S. El-Baz; Luca Saba; Jasjit Suri. Abdomen and Thoracic Imaging, Springer US, pp , 2013, < / >. <inserm > HAL Id: inserm Submitted on 28 Nov 2013 HAL is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. L archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

2

3 Abdomen And Thoracic Imaging, 2014, pp MULTI-ATLAS-BASED SEGMENTATION OF PELVIC STRUCTURES FROM CT SCANS FOR PLANNING IN PROSTATE CANCER RADIOTHERAPY Oscar Acosta (4) (5), Jason Dowling (6), Gael Drean (4) (5), Antoine Simon (4) (5), Renaud de Crevoisier (4) (5) (7), Pascal Haigron (4) (5) 4. INSERM, U1099, Rennes, 35000, France 5. Université de Rennes 1, LTSI, Rennes, 35000, France 6. The Australian e-health Research Center-CSIRO, Brisbane, Australia 7. Département de Radiothérapie, Centre Eugène Marquis, Rennes, 35000, France

4 Abstract In prostate cancer radiotherapy, the accurate identification of the prostate and organs at risk in planning computer tomography (CT) images is an important part of the therapy planning and optimization. Manually contouring these organs can be a time consuming process and subject to intra- and inter-expert variability. Automatic identification of organ boundaries from these images is challenging due to the poor soft tissue contrast. Atlas-based approaches may provide a priori structural information by propagating manual expert delineations to a new individual space; however the inter-individual variability and registration errors may lead to biased results. Multiatlas approaches can partly overcome some of these difficulties by selecting the most similar atlases among a large data base but the definition of similarity measure between the available atlases and the query individual has still to be addressed. The purpose of this chapter is to explain atlas-based segmentation approaches and the evaluation of different atlas-based strategies to simultaneously segment prostate, bladder and rectum from CT images. A comparison between single and multiple atlases is performed. Experiments on atlas ranking, selection strategies and fusion decision rules are carried out to illustrate the presented methodology. Propagation of labels using two registration strategies are applied and the results of the comparison with manual delineations are reported.

5 1. Introduction Prostate cancer is one of the most commonly diagnosed male cancer worldwide[1], with 190,000 new cases diagnosed in USA in 2010 [2] and 71,000 new cases in France in 2011 [3]. In Australia, prostate cancer is the most commonly diagnosed cancer behind skin cancer, and is the second highest cause of cancer-related deaths behind lung cancer [4]. External beam radiation therapy (EBRT) is a major clinical treatment for prostate cancer which has proven to be efficient for tumor control [5]. EBRT uses high energy x-ray beams combined from multiple directions to deposit energy (dose) within the patient tumor region (the prostate) to destroy the cancer cells. Modern treatment techniques offer nowadays improved treatment accuracy through a better planning, delivery, visualization and the correction of patient setup errors. The standard clinical protocol for EBRT treatment planning is shown in Figure 1. During the planning step, CT images from patients are acquired. The treatment targets (prostate and potentially seminal vesicles) along with important normal tissues (rectum, bladder, and femoral heads) are manually delineated using the scans. If MRI is used for the prostate definition then alignment of the MRI and the CT is performed to transfer the MRI structure contours to the CT scan. A defined prostate volume is then expanded to constitute the Planning Target Volume (PTV) for treatment (Figure 2). These spatial margins between the organs and the PTV allow for uncertainties in delineation, patient setup, motion and organ deformations [6] [7] [8]. The next step is the use of computer planning tools to determine the directions, strengths, and shapes of the treatment beams which will be used to deliver a prescribed dose to the defined target while

6 minimizing the dose to the normal tissues, according to a certain number of recommendations (eg.[9] ). Thus, a treatment plan consists of dose distribution information over a 3D matrix of points overlaid onto the individual's anatomy. Dose volume histograms (DVHs) summarize the information contained in the 3D dose distribution and may serve as tools for quantitative evaluation of treatment plans. The International Commission on Radiation Units and Measurements (ICRU) 50 and 62 reports define and describe several target and critical structure volumes that aid in the treatment planning process and that provide a basis for comparison of treatment outcomes. For example, to comply with ICRU recommendations for prostate, 95% of the PTV is irradiated with at least 95% of the prescribed dose. For the rectal wall the maximal dose should be less or equal than 76Gy and the irradiated volume at 72Gy, must be less than 25%. Finally, during the dose delivery step, which may last several weeks, the patient is carefully positioned at the accelerator and the treatment is performed according to the planning. A frequent method to align the patient for treatment is to use small implanted fiducial markers in the prostate. These are visible under x-ray imaging and show precise prostate position within the body. Image guidance may be used to align the treatment target each day for the entire course.

7 Figure 1. Workflow for traditional prostate cancer image guided radiation therapy. The prescribed radiation dose for EBRT is generally delivered over several weeks in small daily amounts (fractions).

8 a) CT scan b) Organ delineation c) PTV Figure 2. Sagittal views of CT scan delineation and definition of the Planned Target Volume (PTV). Figure 3. Typical Intensity Modulated Radiation Therapy (IMRT) plan (axial, coronal and sagittal views) showing iso-dose curves and the (PTV), obtained after organ delineations. One of the main challenges in prostate radiotherapy is to control the tumor, by accurately targeting the prostate, while sparing neighboring organs at risk (bladder and rectum). Several strategies have been developed in order to improve local control, particularly by increasing the radiation dose with highly conformal techniques demonstrating a strong dose-effect relationship [10]. The precision of treatment delivery is steadily improving due to the combination of intensity

9 modulated RT (IMRT) and image-guided RT (IGRT) and intraprostatic fiducial markers. New delivery systems are also populating clinical centers (ARC-Therapy, cyberknife). Hence the possibilities for achieving better control by increasing the dose are within reach. However, dose escalation is limited by rectal and urinary toxicity ([11], [12]). Toxicity events (incontinence, rectal bleeding, stool lose) are frequent with standard prescribed doses (70-80 Gy) and may even significantly increase for higher doses [13]. Thus, accurate delineation of both prostate and organs at risk (OARs) (i.e. bladder, rectum) from planning images are crucial to exploit the new capabilities of the delivery systems [14]. Identifying the boundaries of pelvic structures are of major importance not only at the planning step but also in other radiotherapy stages such as patient setup correction, accumulating dose computation when IGRT is used [15] [16] or for toxicity population studies [17]. Figure 4. Axial view of manual segmentation of bladder, prostate and rectum overlaid on CT scan. Nowadays, the organ contouring tasks are mainly carried out manually by medical experts. However, the CT offers poor soft tissue contrast and therefore segmenting pelvic organs is highly time consuming (between minutes to delineate each). Manual contouring requires training and is prone to errors, especially in the apical and

10 basis regions [18] [19]. These uncertainties lead to large intra- and inter-observer variation [20] and may impact treatment planning and dosimetry [19] [21]. Previous studies, for instance, have reported a prostate delineation variance of 20:60% [20]. For the rectum and bladder this difference may be as high as 2.5 to 3% [22]. Although improved organ contrast may be obtained with Magnetic Resonance Images (MRI), and several studies are in progress to introduce MRI in the radiotherapy planning ([23], [24]), CT scans are still required to perform this task since dose computation relies on electron density. Therefore there is a strong case for more reliable semi or fully automatic CT segmentation techniques. When dealing with automatic segmentation methods for prostate cancer treatment there are several difficulties which may arise. Firstly, there is a poor contrast between prostate, bladder and rectum and, secondly, there may exist a high variability in the amount of bladder and rectum filling. These challenges restrict the use of classical intensity-based segmentation methods. In addition the high intra- and inter-individual variability may cause model-based methods to fail [25]. Figure 5. Two examples of pelvic structures in CT (sagittal views). The poor contrast between structures hampers organ segmentation.

11 Atlas based approaches are common methods for organ segmentation, not only for obtaining a final contour but also to provide initial organ positions for further segmentation algorithms. In atlas-based methods a pre-computed segmentation or prior information in a template space is propagated towards the image to be segmented via spatial normalization (registration). These methods have been largely used in brain MRI ( [26], [27] ), head and neck CT Scans ( [28], [29], [30] ), cardiac aortic CT [31], pulmonary lobes from CT [32] and prostate MR ( [33], [34] ). In the atlas based methods image registration is a key element, as label propagation relies on the registration of one or more templates to a target image. In this chapter a brief overview of image registration and atlas methods will be provided. Atlas based methods which can perform the segmentation of the individuals' pelvic structures, prostate and organs at risk (OAR) from CT scans will be discussed and evaluated against clinical datasets. 2. Image registration 2.1 Introduction Atlas based segmentation is heavily dependent on the quality of image registration. Medical image registration involves determining the spatial transform which maps points from a moving image to homologous points on a object in a fixed image. The general idea of the registration may be summarized as in Figure 6. The basic input data to the registration process are two images: one is defined as the fixed image F(X) and the other as the moving image

12 M(X). The output of the registration is a spatial transformation T allowing the warping or the alignment of the moving image, on the fixed image, according to a similarity metric. Figure 6. Computerized registration framework. As depicted in Figure 6, there are four main components involved in image registration: a similarity measure between two images; the transformation model used to map points between images; a method to find the optimal transform parameters; and finally an interpolator to calculate moving image intensities at non-grid positions [20]. In this sense, registration may be seen as an optimization problem Tˆ arg minc( T ; F( x), M ( x)) (1) T

13 aimed at estimating the spatial mapping that better align the moving image into alignment with the fixed image according to a cost function: C s( F( x), T ( M ( x))) (2) where s( F( x), T ( M ( x)) is the similarity criterion, which provides a measure of how well the fixed image is matched by the transformed moving image. This measure forms the quantitative criterion to be optimized over the search space defined by the parameters of the transform. The similarity may lie on control points, features, anatomical structures, intensities, etc. Here, we restricted the study to the intensity similarity metrics. 2.2 Transform The transform component T(X) represents the spatial mapping of points from the fixed image space to points in the moving image space. The transformation model can either apply to the entire volume (global) or to each voxel (local). The two global methods are: rigid registration which allows only rotations and translations; and affine registration which extends rigid registration with the addition of skew and scaling parameters. Deformable, (also known as non-rigid or non-linear) registration affects individual voxels within the volume. This enables the matching of soft tissues which may deform between scans (eg. a patient s bladder on two CBCT volumes) or when performing interindividual mapping. Typically a regularization constraint is also implemented to constrain the allowable solution space. Deformable

14 methods can be complex and difficult to validate [35]. Common deformable transforms include BSpline free form deformation (FFD) [36], thin plate splines [37], and optical flow inspired approaches (Demons algorithm) [38]. The output from deformable registration is generally a volume (the deformation field) which contains displacement vectors for each voxel as illustrated in Figure 7 a)moving image b) Non-linear transformation c) Fixed image Figure 7. Example of a non-linear transformation obtained when registering the moving image (a) into the espace of the fixed image (b). 2.2 Image similarity metrics When the similarity between two images is based on intensity levels, several metrics can be considered [39] These can be computed via their voxel-wise differences, for example with the sum of squared differences (SSD), or via the cross correlation (CC) or the mutual information (MI). These metrics are computed as follows: SSD 1 n i ( F ( x ) T ( M ( i x i ))) 2 (3)

15 where is the fixed image and represents the transformed moving image. The CC as ) ( i x F )) ( ( i x M T i i i i i i i x M T x M T x F x F x M T x M T x F x F CC 2 2 ))) ( ( )) ( ( ( )) ( ) ( ( ))) ( ( )) ( ( ))( ( ) ( ( (4) and the MI, computed as ), ( ) ( ) ( ), ( M F H M H F H M F MI (5) where H(x) is the individual entropy of an image x, given by ) ( )log ( ) ( i p i p F H i (6) and ), ( ) log, ( ), (, j i p j i p M F H j i (7)

16 is the joint entropy and p the joint probability. The idea behind the term H(F, M), is that maximizing MI is related to minimizing joint entropy. A more robust version of the MI is the normalized mutual information (NMI) proposed by Studholme, et al. [40], and computed as H ( F) H ( M ) NMI( F, M ) (8) H ( F, M ) An important consideration with similarity metrics is the computational cost and the need of a large number of samples for the algorithms to be robust. Novel ways of computing MI, have been proposed [41], yielding comparable results with less samples. This approach approximates the entropy computation using the high order description. For a complete survey of MI, the reader may refer to [42]. 2.3 Optimization The images (or image features), are ideally related to each other by some transformation T. As shown in Figure 6, the iterative process of optimization aims at finding T with a cost function determined by the similarity metric. As the cost function may have multiple local minima, a weighted regularization term may be added to penalize undesirable deformations as C s( F( x), T ( M ( x))) w (9) Examples of include the curvature, the elastic energy, or volume preserving constraints. This term ensure smoothness of T in the nonparametric approaches. There are several ways to perform the optimization of T. These include the deterministic gradient-based algorithms such as gradient-descent, quasi-newton or non-linear

17 gradient descent; or the stochastic gradient-based algorithms such as the Kiefer-Wolfowitz, simultaneous perturbation; Robins Monro and Evolution Strategy, where they derive search directions with stochastic approximations of the derivative. A full evaluation of optimization techniques in a non-rigid registration context was presented by Klein, et al. [33]. They compared several methods with respect to speed, accuracy, precision and robustness. By using a set of CT images of heart and MR images of prostate, it was shown that a stochastic gradient descent technique the Robins-Monro process outperformed the other approaches. Acceleration factors of approximately 500, compared to a basic gradient descent method were achieved. 2.4 Interpolation As depicted in Figure 6, after a transformation is applied to the moving image, an interpolation is performed which enables evaluation of the moving image intensities at non-grid positions. To resample the moving image in the fixed image grid, the transformation can be applied either in a forward or backward manner. In the forward way, each voxel from the moving image can be directly transformed using the estimated mapping functions. Because of the discretization, this approach can produce holes and/or overlaps in the transformed image. Hence, the backward approach is more convenient and usually implemented. In this approach, the image interpolation takes place on the regular grid in the space of the fixed image. Thus, the registered image data from the moving image are determined using the coordinates of the target voxel and the inverse of the estimated transformation. In this way, neither holes nor overlaps can occur in the output image. Thus, depending on the required precision different alternatives exist for this resampling, for instance the nearest neighbor

18 (NN), tri-linear, BSpline (BS), Cubic interpolations (CI), etc. However, some artefacts may be introduced as a consequence of the iterative process. These interpolation-related errors in image registration have been studied by Pluim, et al. [43]. Thevenaz, et al. [44] have proposed a different approach to image resampling. Unlike the other methods, their resampling functions do not necessarily interpolate the image gray levels but values calculated as certain functions of the gray levels. The authors demonstrated how this approach outperforms traditional interpolation techniques. Several survey papers on resampling techniques have been published recently ([45], [46], [47], [48]). In practical terms, although higher-order methods may yield good result in terms of accuracy, the tri-linear interpolation offers a very good trade-off between accuracy and computational complexity. Cubic or spline interpolation is recommended when the transformation involves significant geometrical differences, as several voxels may be interpolated in between available information. Nearest neighbor interpolation produces several artefacts but is advised when the image to be transformed contains low number of intensities. For example, when propagating labels in atlas-based segmentation approaches, this is the preferred approach. 3. General atlas construction and segmentation strategies 3.1 Introduction The key idea in atlas-based segmentation is to use image registration to map one or more pre-labeled images (or atlas ) onto a new patient image. Once a good correspondence between structurally equivalent regions in the two images is achieved the labels defined on

19 the atlas can be propagated to the image. Rohlfing, et al. [49] have identified four main methods to generate the atlas which is registered to a target volume: using a single labeled image, generating an average shape image, selecting the most similar image from a database of scans; or finally to register all individual scans from a database and using multi-classier fusion to combine the pair-wise registration results. An atlas A i is constituted by a template image I i and, a set of generated labels i defined in the same coordinate system. In the case of pelvic structures from CT scans, the set of labels i { prostate, rectum, bladder}. The general framework of atlasbased segmentation, as depicted in Figure 8, relies on the registration of the template I i, to the query image I q in order to obtain a transformation T, that maps I i I q i into I q. If the mapping is anatomically correct, the yielded segmentation is accurate and anatomically meaningful. It is worth nothing that the similarity between the images I i and I q, as explained in previous sections may impact the registration results and therefore the segmentation.

20 Figure 8. Atlas Based Segmentation Strategy Several issues may arise under this framework in order to produce accurate segmentations. Firstly, the selection and generation of the initial patient scan which may be representative of a population; secondly, the registration strategy to bring Ii into the space of I q ; and finally, the propagation of the labels i into I q.and the subsequent generation of the new segmentation. Concerning the first issue, a typical individual from a given population may constitute an atlas, where the segmentation i may be manually generated on I i. This is the simplest strategy, but with the problems related to the inter-individual variability and inter-observer rating arising. However, in order to attenuate the dependency on a single observer, a group of experts can generate the set of labels, adding robustness to the definition of i. To a larger extent, to cope with the inter-individual variability, several individuals from a population can be used to constitute the atlas. In this case, two kinds of strategies may be followed. Either an atlas is built from the population by averaging the data ( Ii, i i 0,..,M ) or alternatively each individual is q

21 considered as a single atlas. In that case, for a given query, there is a previous selection of the best n atlases A i, i 0,.., M which better fit to the query I q. The last strategy allows for a reduction of the bias inherent to using a single template, but new questions arise concerning the best atlas selection strategy and label fusion decisions to constitute the final segmentation q. These points are detailed in the following sections. Proposed experiments compare the performances of those for segmenting prostate, bladder and rectum. 3.2 Average atlas construction An atlas can be computed in an iterative process as depicted in Figure 9. This approach was used in a comparative study that we presented in [17], but also is detailed in [50]. In this scheme, an arbitrary but representative individual was chosen as the initial template, defining the atlas space alignment. The first iteration involves the registration of every other individual to the selected template using a rigid or affine registration method (i.e. robust block matching approach [51], followed by a non-rigid registration [38] in the subsequent iterations. At the end of each iteration, a new average atlas is generated and used in the subsequent iteration.

22 Figure 9. Iterative averaging for obtaining a template After the average template is obtained, a probabilistic set of soft labels i (probability maps) is eventually generated by propagating the manual segmentations of these organs for each case using the obtained affine transform and deformation field into the atlas space. Figure 10 shows the obtained template after five iterations and Figure 11, depicts an overlaid of the probabilistic labeling for the prostate in the atlas coordinate system.

23 Figure 10. Example of a) Individual's CT and b) Averaged template The drawbacks of this strategy within the context of CT pelvic segmentation come from the large inter-individual variability and the poorly contrasted average atlas which is produced after several iterations. In order to diminish the bias inherent to using a single template, one potential strategy is to select one patient amongst typical individuals from a database, who is quite similar to the majority of individuals. Additional benefits may be brought to the segmentation by combining the results from multiple atlases, improving the accuracy as explained in the next section.

24 Figure 11. Generation of organ probability maps by propagating labels into the common template 3.3 Multi-atlas strategy: selecting the N best atlas from a database Previous works have shown the benefits to combine multiple atlases (multi-atlases-based approaches), improving the segmentation accuracy (eg. [26], [31], [27], [52] ). Thus, given a query individual, different possibilities appear. Either the closest individual from the database is selected as the best atlas or all the atlases are combined together as in the strategy depicted in Figure 12. In this approach, the atlases are firstly ranked according to the similarity to the query image. This is done after a rigid or affine registration step which allows for the inter-individual differences to be assessed. Then, in the steps 2 and 3, labels from the top n ranked atlases are propagated towards the individual CT via non-rigid registration to more accurately match template anatomies. Finally, in a fusion-decision step, organ segmentations are obtained by combining different labels. The

25 particular case n=1 corresponds to the most similar individual atlas strategy. Figure 12. Multi-atlas-based segmentation process. Atlas are first ranked according to the similarity to the query image, then, labels from the top n ranked atlases are propagated towards the individual CT and finally, in a fusion-decision step, organ segmentations are obtained. The questions arising in this scheme concern i) the method for selecting the atlases to be used and particularly the most convenient similarity metric, ii) the non-rigid registration technique and iii) the fusion-decision rules (discussed in the next sub-section).

26 The similarity measure can be based on the difference of intensity levels, for example, as explained in previous sections: the sum of squared differences, the cross correlation or the mutual information. The similarity can be also based on information obtained from the deformation [53], such as the Jacobian. The drawback of the Jacobian is the dependency on the registration method used to align the images. Two registration strategies are tested and discussed later in a further section, namely FFD [36] and the demons algorithm [54]. 3.4 Label fusion For both the average and multi-atlas approaches a method for combining labels needs to be implemented. This fusion step occurs at the voxel level during each training iteration of average atlas construction, and when combining propagated labels from selected atlases in a multi-atlas scheme. Majority voting simply counts the number of label overlaps (or votes) on a single voxel from each registered atlas and chooses the voxels receiving the most votes to produce the final label. In a probabilistic voting scheme, the labels mapped to the each voxel are combined to give an estimate of label likelihood (ie. a value of 0 means that no labels were mapped to that voxel location, and a value of 1 for a voxel means that all labels were mapped to that voxel location). The probabilistic segmentation can then be thresholded at a particular probability (typically 0.5) to give a degree of confidence for the label location. A more elaborate approach assigns a weight to voxels that are located at a particular location (eg. the centre of a structure of interest) or which contain more similar intensities (both within the training image labeled regions, or globally) [55], [31].

27 An alternate method to fusing labels which has been applied to prostate segmentation was proposed in the Selective and Iterative Method for Performance Level Estimation (SIMPLE) approach. In this method the labels to fuse are selected according to a similarity metric. The quality of the label segmentation is then improved by discarding the poorly correlated labels from the fused result. This process then iterates until a desired level of label similarity is achieved [56]. The Simultaneous Truth and Performance Level Estimation (STAPLE) is a popular approach which uses Expectation Maximisation to iterate between the estimation of the true consensus segmentation and the estimation of reliability parameters for each of the propagated segmentations [57]. The sensitivity and specificity of each propagated label are used to weight the contributions when generating the consensus label estimate. The current consensus estimate can, in turn, be used to measure the reliability of the raters and this forms the basis of the EM iterations [26]. 4. Experiments and Results 4.1 Average atlas based segmentation This section describes the construction and application of an average atlas to perform segmentation using a single template. The work in this section was motivated by the importance of applying spatial specific predictive models for toxicity [17].

28 Data and methods The study consisted of nineteen patients who were receiving external beam radiation therapy for prostate cancer. Each patient underwent a planning CT scan and 8 more weekly CT scans. All CT scans were acquired without contrast enhancement. The size of the images in the axial plane was 512x512 pixels with 1 mm resolution 3-mm thick slices. For each patient, the femur, the bladder, the rectum, the prostate and the seminal vesicles (SV) were manually contoured by the same observer of these organs for each case using the obtained affine transform and deformation field previously computed. An arbitrary but representative case in our database was selected as the initial atlas, defining the atlas space alignment. A pipeline as detailed in Figure 9 was applied to generate an average template. The first iteration involved the registration of every other case to the selected individual case using a robust block matching approach [51], followed by a diffeomorphic demons non-rigid registration [58] in the subsequent iterations. At the end of each iteration a new average atlas was generated and used in the subsequent iteration. In this study, five iterations were performed. After generation of the probabilistic labels (Prostate, rectum, bladder) in the common space, the atlas was used in a segmentation step to constrain the organs of interest. Thus, a scheme based on affine, followed by a diffeomorphic Demons non-rigid registration led us to map the atlas onto each individual s CT scan. The obtained affine transform and deformation fields were then used to map the probabilistic labels onto each individual scan. These registered labels were thresholded at 50% to provide the organ segmentations for each individual scan.

29 Results a) axial b) coronal c) sagittal Figure 13. Prostate probability maps overlaid on the generated atlas orthogonal axial, coronal and sagittal slices. The generated atlas and an example of probabilistic label are shown in Figure 13. Figure 14 depicts the overlap between the atlas and a single individual. The non rigid registration scheme obtains good correspondence between the two images, although the soft tissue contrast is still quite low. Notably the bladder and rectum alignment is better with the template than the prostate, as the intensity contrast in those organs is higher. The automatic hard segmentations were quantitatively compared against the manual segmentations using the Dice Similarity Coefficient (DSC) [59]: X Y DSC 2 X Y (10)

30 A leave-one-out cross validation was performed (at each iteration a single individual was extracted from the training data and used as a test). The DSC results appear summarized in Figure 15. The results for the bladder and rectum were reasonable as there is good contrast in the CT. Figure 14. Axial slice showing registration result between the atlas and a single individual. In general a good agreement was obtained with this approach. The main cause of error in the automatic segmentation results are related to inter-individual organ variation. Obesity appears to be a source of error, as it induces a quite important variability to the training data set. We must also consider the high inter-observer variability which also creates bias in the obtained results. This could be alleviated with the contribution of additional subjects to the atlas or with the computation of a set of atlases to stratify subjects. This will allow to group portions of the populations that can be further mapped together into a single template.

31 Figure 15. Results from leave one out validation using the average atlas. DSC results are displayed for all labeled organs (Bladder, Rectum and Prostate) Discussion The automatic segmentation of the prostate, rectum, bladder from CT images using a probability atlas scheme had reasonable correspondence with the manual segmentation, and may provide useful initial constraints for further segmentation methods, such as active contours or statistical models (e.g. [60], [61]). However, these examples point out the main concerns of a single average atlas. The contrast is very low, there is a large inter-individual variability, and considered structures are heterogeneous leading sin several cases to low DSC scores.

32 Problems appear when a single patient scan is used as the initial target for average atlas construction since the atlas is biased towards that patient s anatomy. It is expected that further improvement is brought by the selection and combination of several scans which are more similar to the query image as explained in the next section. 4.2 Evaluation of multi-atlas based segmentation In this section, we evaluated several multi-atlas based strategies, as an extension of [52], taking into account the different stages of the pipeline depicted in Figure 12.i) selection of the atlases based on three different metrics: sum of squared differences, cross correlation and mutual information;

33 ii) non-rigid registration using both Free Form Deformation and the demon's algorithm with multi atlas label propagation; iii) multi-label decision fusion using classical voting rule compared to the STAPLE method [57]. Erreur! Source du renvoi introuvable. summarizes the considered methods. Data and methods The images used in this experiment consisted of thirty patients treated for prostate cancer, who underwent a planning CT scan. All CT scans acquired were 2-mm slice thickness with 512x512 pixels of 1 mm in the axial plane. For each patient, the organs were manually contoured by the same expert observer, following the clinical protocol for the therapy. In this study, only the segmented prostate, bladder and rectum were considered. Following a leave-one-out cross validation scheme we assessed the impact of the atlas selection methods by comparing individual s manual segmentations with the obtained hard segmentations using the DSC. Thus, at each iteration a single individual was extracted from the training data and used as a test. The comparisons were done in two steps, first after affine alignment, aimed at quantifying the reliability of the similarity criteria. Then, as depicted in Erreur! Source du renvoi introuvable., the set of atlas was ranked according to a given similarity criteria and the ith-ranked atlases were taken. This atlas was used to segment the query image via two non-rigid registration strategies (FFD and Demons) that were compared. In a further experiment, a multiple atlas strategy allowed two label fusion methods (VOTE and STAPLE) to be compared. Selecting only the i-th ranked atlas

34 For each template, the registered individuals were ranked according to the similarity criteria computed on the masks of the union of the prostates, the union of the bladders, and the unions of the rectums after a rigid registration. Then we computed the average dice score for only the ith-top-ranked individual (with i = 1..30). Finally, Pearson score (R) was computed between the rank and the average dice score with the aim of assessing the best similarity metric able to predict the best template from a database. Increasing the number of ranked atlas. Selection of the best n- ranked atlas In an additional experiment, we assessed the effect of the number of atlases selected after ranking, by progressively including a new atlas to the segmentation step. The two schemes of decision rule were tested, voting and STAPLE and two non-rigid registration strategies were compared (FFD and Demons) as depicted in Figure 19 Results We first computed the average DSC when using only the ith-ranked atlas to segment, where i spans 1 to 29. Erreur! Source du renvoi introuvable. depicts for a single individual an example of overlapping between top-ranked and bottom-ranked atlases and a single individual. A significant difference between propagated structures appears depending on the atlas used to segment. In average, the SSD seems to be a better predictor of overlapping for the prostate and the rectum. The results of correlations between ranking and DSC for three organs and similarity measures are summarized in Table 1. The largest dependency with the rank appears in the bladder when the

35 CC is used. Indeed, this organ is very prone to deformations and exhibits a high interindividual variability that was better detected with the CC. R = 0.76 than with the SSD R = Unlike these measures, the MI offers a poor agreement, therefore it was not considered in the following experiments. We are in a monomodality context, and MI would be supposed to work better for measuring similarities between multimodal images. Figure 16. Top: Example of bladder segmentation with three different atlases (from top-ranked to bottom-ranked). The query individual is matched to the atlas data set via three similarity metrics: CC, SSD and MI. The most similar atlas yields a better result.

36 A significant improvement in the overlap was brought by the demons non-rigid registration. In average for the prostate 23.2% (p < ), for the rectum 24.8% (p < ) and for the bladder 35.0% (p < ). Further, with the demons algorithm the dependency on the selected ith-ranked atlas tends to become weaker, as shown by the correlation coefficients, which for some cases tends to be lower. This is due to the fact that the non-rigid registration is more accurate, which compensates for large differences between individuals. Consequently, the overlap was significantly improved when the lower-rank atlases were selected. The poor contrast between the prostate and bladder led in some cases to mis-registration problems when the images are quite dissimilar. The rectum, when not empty, was also poorly registered, although the results are still dependant on the rank of the selected atlas. Table 1. Correlation (R) between the average Dice score and the rank of the atlas used to segment, firstly, after affine registration (AFF) and then after nonrigid registration (NRR). Organ Registration MI CC SSD Prostate AFF Bladder AFF Rectum AFF Prostate NRR Bladder NRR Rectum NRR Increasing the number of ranked atlases within the segmentation Results of progressively increasing the number of atlas within the segmentation are depicted in Figure 17 to Figure 23. Firstly, a comparison between different registration strategies (rigid, FFD,

37 Demons) are depicted (Figure 17 to Figure 20). In this case, the majority vote was used for label fusion because it yielded the best result to compare. It can be seen that as the number of atlas increases there is a clear improvement when using demons. The same trend exists for the three obtained organ segmentations after the inclusion of 20 atlases shown in Figure 20. Figure 24 to Figure 23, compares STAPLE to majority vote. In case of STAPLE, the trust given to each atlas was the same. It is shown that as the number of selected atlases increased, the performance of the segmentations was firstly improved in both cases. Then, after several atlases were included the quality tends to a stable value with a lower variance for the vote, unlike STAPLE which exhibits a different behaviour. Indeed for the three organs the quality of the segmentations steadily decreases for STAPLE. Results on these data suggest that the vote-decision rule is more robust to high interindividual variability. In average, for the prostate and the rectum the differences between both methods became statistically significant (p < ) after 12 topranked atlases were combined. For the bladder, these differences are significant (p < 0.01) after 23 atlases.

38 Figure 17. DSC scores for prostate segmentation as the number atlases increased. Comparison between the different registration strategies. Figure 18. DSC scores for bladder segmentation as the number atlases increased. Comparison between different registration strategies.

39 Figure 19. DSC scores for rectum segmentation as the number of atlases increased. Comparison between different registration strategies.

40 a) Prostate-Rigid b) Prostate-FFD c) Prostate-Demons d) Rectum-Rigid e) Rectum-FFD f) Rectum-Demons g) Bladder-Rigid h) Bladder-FFD i) Bladder-Demons Figure 20. Example of segmentations for prostate, rectum and bladder, after including 20 atlases. Comparison between rigid, FFD and demons registration. Label fusion with majority voting. Blue label is the ground truth, red is the obtained segmentation.

41 Figure 21. Dice scores for prostate segmentation as a function of the number of best atlases used. Comparison between vote and STAPLE Figure 22. Dice scores for bladder segmentation as a function of the number of best atlases used. Comparison between vote and STAPLE

42 Figure 23. Dice scores for prostate segmentation as a function of the number of best atlases used. Comparison between vote and STAPLE

43 a) Prostate-STAPLE b) Prostate-vote c) Rectum-STAPLE d) Rectum-vote e) Bladder-STAPLE f) Bladder-vote Figure 24. Comparison between vote and STAPLE after inclusion of 20 atlases (Registration was performed with demons). Conclusion We have presented a study aimed at evaluating different atlas selection strategies for mapping of organs in pelvic CT for prostate cancer radiotherapy planning. We quantified the influence of multiple atlas selection based on three similarity measures and computed both the effects of the ranking according to these measures and the dependency on the number of atlases used. Results suggest that SSD is a better

44 predictor for mapping than the MI and is slightly similar to the CC. Considering the fusion decision rules the vote performed better than STAPLE. With the vote, combining more than one similar atlas may be more robust, but as the number of dissimilar atlases increased, the results tend to remain stable, at expense of computation time. A good compromise would be to use the top 20% ranked atlases. To increase the specificity of similarity measures as predictors for segmentation, more local similarity measures may be used, computed only in regions close to the considered organs or including other individual s characteristics, such as the patient weight. Another possibility relates to the inclusion of additional individuals within the atlas data base for query. Finally, different non-rigid registration methods can be validated within the same framework. 5. Summary Atlas based methods provide very useful tools for image analysis and generating automatic organ labels. This chapter has provided an overview of atlas based analysis applied to planning images in external beam radiation therapy treatment for the prostate. All atlas-based approaches depend on the quality of image registration used. Careful decisions need to be made about the transformation model, similarity metric and the optimization method used to deform a moving volume onto a target volume. Two main types of atlas have been described. The first is an average atlas approach where a single average volume is generated from a training set along with a set of labels. This average atlas is then registered to a target volume, and the same transform or deformation is

45 then applied to the atlas labels to provide automatic label, or segment, the target volume. A constraint with the average atlas approach is that atlas is biased towards the initial target patient selected during atlas construction and the atlas may not generalize to a wider population with different anatomy. The second, multi-atlas, approach involves pair-wise registration between each volume in an atlas set and the target volume. Following this, the registered volumes and the target volume are compared and the transformed labels from the most similar registration results are combined (or fused) to provide an automatic segmentation. There are a number of methods to fuse labels, however the most common method involves a simple voting approach. A number of previous papers have suggested that when adequate patients are included in the atlas set the multi-atlas approach has been found to lead to improved segmentation results. Experiments involving both types of atlas have been presented in this chapter, and the results have found that for CT monomodal atlas based analysis the use of a multi-atlas approach with correlation or sum of squared differences are better suited to handle large inter-patient anatomical variations.

46 6. References [1] GLOBOCAN, "Prostate Cancer Incidence and Mortality Worldwide in 2008," [2] A. Jemal, F. Bray, M. M. Center, J. Ferlay, E. Ward, and D. Forman, "Global cancer statistics," CA Cancer J Clin, vol. 61, pp , [3] INCa, "La situation du cancer en France en 2011-Rapport Institut National Du Cancer," INCa, rapport 14 Novembre [4] AIHW, "Cancer in Australia: an overview," Australian Institute of Health and Welfare (AIHW) & Australasian Association of Cancer Registries (AACR) Cancer series no. 37, [5] S. J. S. Grimsley, M. H. Khan, E. Lennox, and P. H. Paterson, "Experience with the spanner prostatic stent in patients unfit for surgery: an observational study," J Endourol, vol. 21, pp , [6] S. A. Mangar, R. A. Huddart, C. C. Parker, D. P. Dearnaley, V. S. Khoo, and A. Horwich, "Technological advances in radiotherapy for the treatment of localised prostate cancer," Eur J Cancer, vol. 41, pp , [7] M. Guckenberger and M. Flentje, "Intensity-modulated radiotherapy (IMRT) of localized prostate cancer: a review and future perspectives," Strahlenther Onkol, vol. 183, pp , [8] P. Cheung, K. Sixel, G. Morton, D. A. Loblaw, R. Tirona, G. Pang, R. Choo, E. Szumacher, G. Deboer, and J. P. Pignol, "Individualized planning target volumes for intrafraction

47 motion during hypofractionated intensity-modulated radiotherapy boost for prostate cancer," Int J Radiat Oncol Biol Phys, vol. 62, pp , [9] V. Beckendorf, S. Guerif, E. Le Prise, J. M. Cosset, A. Bougnoux, B. Chauvet, N. Salem, O. Chapet, S. Bourdain, J. M. Bachaud, P. Maingon, J. M. Hannoun-Levi, L. Malissard, J. M. Simon, P. Pommier, M. Hay, B. Dubray, J. L. Lagrange, E. Luporsi, and P. Bey, "70 Gy versus 80 Gy in localized prostate cancer: 5-year results of GETUG 06 randomized trial," Int J Radiat Oncol Biol Phys, vol. 80, pp , [10] A. L. Zietman, M. L. DeSilvio, J. D. Slater, C. J. Rossi, Jr., D. W. Miller, J. A. Adams, and W. U. Shipley, "Comparison of conventional-dose vs high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate: a randomized controlled trial," Jama, vol. 294, pp , [11] V. Fonteyne, G. Villeirs, B. Speleers, W. De Neve, C. De Wagter, N. Lumen, and G. De Meerleer, "Intensity-modulated radiotherapy as primary therapy for prostate cancer: report on acute toxicity after dose escalation with simultaneous integrated boost to intraprostatic lesion," Int J Radiat Oncol Biol Phys, vol. 72, pp , [12] C. Fiorino, T. Rancati, and R. Valdagni, "Predictive models of toxicity in external radiotherapy: dosimetric issues," Cancer, vol. 115, pp , [13] R. de Crevoisier, C. Fiorino, and B. Dubray, "Dosimetric factors predictive of late toxicity in prostate cancer radiotherapy," Cancer Radiothérapie vol. 14, pp , [14] C. F. Njeh, "Tumor delineation: The weakest link in the search for accuracy in radiotherapy," Journal of Medical Physics, vol. 33, pp , [15] G. Cazoulat, M. Lesaunier, A. Simon, P. Haigron, O. Acosta, G. Louvel, C. Lafond, E. Chajon, J. Leseur, and R. de

48 Crevoisier, "From image-guided radiotherapy to dose-guided radiotherapy," Cancer Radiother, vol. 15, pp , [16] T. Chen, S. Kim, J. Zhou, D. Metaxas, G. Rajagopal, and N. Yue, "3D meshless prostate segmentation and registration in image guided radiotherapy," Med Image Comput Comput Assist Interv, vol. 12, pp , [17] O. Acosta, J. Dowling, G. Cazoulat, A. Simon, O. Salvado, R. de Crevoisier, and P. Haigron, "Atlas Based Segmentation and Mapping of Organs at Risk from Planning CT for the Development of Voxel-Wise Predictive Models of Toxicity in Prostate Radiotherapy," presented at Prostate Cancer Imaging. Computer-Aided Diagnosis, Prognosis, and Intervention, International Workshop in MICCAI 2010, [18] D. C. Collier, S. S. Burnett, M. Amin, S. Bilton, C. Brooks, A. Ryan, D. Roniger, D. Tran, and G. Starkschall, "Assessment of consistency in contouring of normal-tissue anatomic structures," J Appl Clin Med Phys, vol. 4, pp , [19] C. Fiorino, M. Reni, A. Bolognesi, G. M. Cattaneo, and R. Calandrino, "Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning," Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology, vol. 47, pp , [20] X. Gual-Arnau, M. V. Ibanez-Gual, F. Lliso, and S. Roldan, "Organ contouring for prostate cancer: interobserver and internal organ motion variability," Comput Med Imaging Graph, vol. 29, pp , [21] C. Fiorino, V. Vavassori, G. Sanguineti, C. Bianchi, G. M. Cattaneo, A. Piazzolla, and C. Cozzarini, "Rectum contouring variability in patients treated for prostate cancer: impact on rectum dose-volume histograms and normal tissue

4 CIM&Lab, Universidad Nacional de Colombia, Bogota, Colombia {edromero,

4 CIM&Lab, Universidad Nacional de Colombia, Bogota, Colombia {edromero, Segmentation of pelvic structures from planning CT based on a statistical shape model with a multiscale edge detector and geometrical likelihood measures Fabio Martinez 1,2,4, Oscar Acosta 1,2, Gaël Dréan

More information

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology VALIDATION OF DIR Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology Overview Basics: Registration Framework, Theory Discuss Validation techniques Using Synthetic CT data & Phantoms What metrics to

More information

Multi-atlas labeling with population-specific template and non-local patch-based label fusion

Multi-atlas labeling with population-specific template and non-local patch-based label fusion Multi-atlas labeling with population-specific template and non-local patch-based label fusion Vladimir Fonov, Pierrick Coupé, Simon Eskildsen, Jose Manjon, Louis Collins To cite this version: Vladimir

More information

Methodological progress in image registration for ventilation estimation, segmentation propagation and multi-modal fusion

Methodological progress in image registration for ventilation estimation, segmentation propagation and multi-modal fusion Methodological progress in image registration for ventilation estimation, segmentation propagation and multi-modal fusion Mattias P. Heinrich Julia A. Schnabel, Mark Jenkinson, Sir Michael Brady 2 Clinical

More information

Is deformable image registration a solved problem?

Is deformable image registration a solved problem? Is deformable image registration a solved problem? Marcel van Herk On behalf of the imaging group of the RT department of NKI/AVL Amsterdam, the Netherlands DIR 1 Image registration Find translation.deformation

More information

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT Anand P Santhanam Assistant Professor, Department of Radiation Oncology OUTLINE Adaptive radiotherapy for head and

More information

Coverage based treatment planning to accommodate organ deformable motions and contouring uncertainties for prostate treatment. Huijun Xu, Ph.D.

Coverage based treatment planning to accommodate organ deformable motions and contouring uncertainties for prostate treatment. Huijun Xu, Ph.D. Coverage based treatment planning to accommodate organ deformable motions and contouring uncertainties for prostate treatment Huijun Xu, Ph.D. Acknowledgement and Disclosure Dr. Jeffrey Siebers Dr. DJ

More information

Auto-Segmentation Using Deformable Image Registration. Disclosure. Objectives 8/4/2011

Auto-Segmentation Using Deformable Image Registration. Disclosure. Objectives 8/4/2011 Auto-Segmentation Using Deformable Image Registration Lei Dong, Ph.D. Dept. of Radiation Physics University of Texas MD Anderson Cancer Center, Houston, Texas AAPM Therapy Educational Course Aug. 4th 2011

More information

Prototype of Silver Corpus Merging Framework

Prototype of Silver Corpus Merging Framework www.visceral.eu Prototype of Silver Corpus Merging Framework Deliverable number D3.3 Dissemination level Public Delivery data 30.4.2014 Status Authors Final Markus Krenn, Allan Hanbury, Georg Langs This

More information

Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases

Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases Automatic Segmentation of Parotids from CT Scans Using Multiple Atlases Jinzhong Yang, Yongbin Zhang, Lifei Zhang, and Lei Dong Department of Radiation Physics, University of Texas MD Anderson Cancer Center

More information

Overview of Proposed TG-132 Recommendations

Overview of Proposed TG-132 Recommendations Overview of Proposed TG-132 Recommendations Kristy K Brock, Ph.D., DABR Associate Professor Department of Radiation Oncology, University of Michigan Chair, AAPM TG 132: Image Registration and Fusion Conflict

More information

Good Morning! Thank you for joining us

Good Morning! Thank you for joining us Good Morning! Thank you for joining us Deformable Registration, Contour Propagation and Dose Mapping: 101 and 201 Marc Kessler, PhD, FAAPM The University of Michigan Conflict of Interest I receive direct

More information

Automated segmentation methods for liver analysis in oncology applications

Automated segmentation methods for liver analysis in oncology applications University of Szeged Department of Image Processing and Computer Graphics Automated segmentation methods for liver analysis in oncology applications Ph. D. Thesis László Ruskó Thesis Advisor Dr. Antal

More information

IMRT site-specific procedure: Prostate (CHHiP)

IMRT site-specific procedure: Prostate (CHHiP) IMRT site-specific procedure: Prostate (CHHiP) Scope: To provide site specific instructions for the planning of CHHIP IMRT patients Responsibilities: Radiotherapy Physicists, HPC Registered Therapy Radiographers

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT 3 ADVANCING CANCER TREATMENT SUPPORTING CLINICS WORLDWIDE RaySearch is advancing cancer treatment through pioneering software. We believe software has un limited potential, and that it is now the driving

More information

Spatio-Temporal Registration of Biomedical Images by Computational Methods

Spatio-Temporal Registration of Biomedical Images by Computational Methods Spatio-Temporal Registration of Biomedical Images by Computational Methods Francisco P. M. Oliveira, João Manuel R. S. Tavares tavares@fe.up.pt, www.fe.up.pt/~tavares Outline 1. Introduction 2. Spatial

More information

radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI

radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li NCAAPM Spring Meeting 2010 Madison, WI GPU-Accelerated autosegmentation for adaptive radiotherapy Andrew Godley, Ergun Ahunbay, Cheng Peng, and X. Allen Li agodley@mcw.edu NCAAPM Spring Meeting 2010 Madison, WI Overview Motivation Adaptive

More information

Computed Tomography to Ultrasound 2D image registration evaluation for atrial fibrillation treatment

Computed Tomography to Ultrasound 2D image registration evaluation for atrial fibrillation treatment Computed Tomography to Ultrasound 2D image registration evaluation for atrial fibrillation treatment Zulma Sandoval, Jean-Louis Dillenseger To cite this version: Zulma Sandoval, Jean-Louis Dillenseger.

More information

Real-time FEM based control of soft surgical robots

Real-time FEM based control of soft surgical robots Real-time FEM based control of soft surgical robots Frederick Largilliere, Eulalie Coevoet, Laurent Grisoni, Christian Duriez To cite this version: Frederick Largilliere, Eulalie Coevoet, Laurent Grisoni,

More information

Motion artifact detection in four-dimensional computed tomography images

Motion artifact detection in four-dimensional computed tomography images Motion artifact detection in four-dimensional computed tomography images G Bouilhol 1,, M Ayadi, R Pinho, S Rit 1, and D Sarrut 1, 1 University of Lyon, CREATIS; CNRS UMR 5; Inserm U144; INSA-Lyon; University

More information

Using Probability Maps for Multi organ Automatic Segmentation

Using Probability Maps for Multi organ Automatic Segmentation Using Probability Maps for Multi organ Automatic Segmentation Ranveer Joyseeree 1,2, Óscar Jiménez del Toro1, and Henning Müller 1,3 1 University of Applied Sciences Western Switzerland (HES SO), Sierre,

More information

Object Identification in Ultrasound Scans

Object Identification in Ultrasound Scans Object Identification in Ultrasound Scans Wits University Dec 05, 2012 Roadmap Introduction to the problem Motivation Related Work Our approach Expected Results Introduction Nowadays, imaging devices like

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT The RayPlan treatment planning system makes proven, innovative RayStation technology accessible to clinics that need a cost-effective and streamlined solution. Fast, efficient and straightforward to use,

More information

TG 132: Use of Image Registration and Fusion in RT

TG 132: Use of Image Registration and Fusion in RT TG 132: Use of Image Registration and Fusion in RT Kristy K Brock, PhD, DABR, FAAPM Associate Professor Department of Radiation Oncology, University of Michigan Chair, AAPM TG 132: Image Registration and

More information

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department Image Registration Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department Introduction Visualize objects inside the human body Advances in CS methods to diagnosis, treatment planning and medical

More information

Deformetrica: a software for statistical analysis of anatomical shapes

Deformetrica: a software for statistical analysis of anatomical shapes Deformetrica: a software for statistical analysis of anatomical shapes Alexandre Routier, Marcel Prastawa, Benjamin Charlier, Cédric Doucet, Joan Alexis Glaunès, Stanley Durrleman To cite this version:

More information

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM Contour Assessment for Quality Assurance and Data Mining Tom Purdie, PhD, MCCPM Objective Understand the state-of-the-art in contour assessment for quality assurance including data mining-based techniques

More information

Hierarchical Multi structure Segmentation Guided by Anatomical Correlations

Hierarchical Multi structure Segmentation Guided by Anatomical Correlations Hierarchical Multi structure Segmentation Guided by Anatomical Correlations Oscar Alfonso Jiménez del Toro oscar.jimenez@hevs.ch Henning Müller henningmueller@hevs.ch University of Applied Sciences Western

More information

PROSTATE CANCER DETECTION USING LABEL IMAGE CONSTRAINED MULTIATLAS SELECTION

PROSTATE CANCER DETECTION USING LABEL IMAGE CONSTRAINED MULTIATLAS SELECTION PROSTATE CANCER DETECTION USING LABEL IMAGE CONSTRAINED MULTIATLAS SELECTION Ms. Vaibhavi Nandkumar Jagtap 1, Mr. Santosh D. Kale 2 1 PG Scholar, 2 Assistant Professor, Department of Electronics and Telecommunication,

More information

Segmentation of pelvic structures for planning CT using a geometrical shape model tuned by a multi-scale edge detector.

Segmentation of pelvic structures for planning CT using a geometrical shape model tuned by a multi-scale edge detector. Segmentation of pelvic structures for planning CT using a geometrical shape model tuned by a multi-scale edge detector. Fabio Martínez, Eduardo Romero, Gaël Dréan, Antoine Simon, Pascal Haigron, Renaud

More information

Adaptive Local Multi-Atlas Segmentation: Application to Heart Segmentation in Chest CT Scans

Adaptive Local Multi-Atlas Segmentation: Application to Heart Segmentation in Chest CT Scans Adaptive Local Multi-Atlas Segmentation: Application to Heart Segmentation in Chest CT Scans Eva M. van Rikxoort, Ivana Isgum, Marius Staring, Stefan Klein and Bram van Ginneken Image Sciences Institute,

More information

Non-rigid Image Registration

Non-rigid Image Registration Overview Non-rigid Image Registration Introduction to image registration - he goal of image registration - Motivation for medical image registration - Classification of image registration - Nonrigid registration

More information

Dosimetric Analysis Report

Dosimetric Analysis Report RT-safe 48, Artotinis str 116 33, Athens Greece +30 2107563691 info@rt-safe.com Dosimetric Analysis Report SAMPLE, for demonstration purposes only Date of report: ----------- Date of irradiation: -----------

More information

From medical imaging to numerical simulations

From medical imaging to numerical simulations From medical imaging to numerical simulations Christophe Prud Homme, Vincent Chabannes, Marcela Szopos, Alexandre Ancel, Julien Jomier To cite this version: Christophe Prud Homme, Vincent Chabannes, Marcela

More information

Accounting for Large Geometric Changes During Radiotherapy. Disclosures. Current Generation DIR in RT 8/3/2016

Accounting for Large Geometric Changes During Radiotherapy. Disclosures. Current Generation DIR in RT 8/3/2016 Accounting for Large Geometric Changes During Radiotherapy Geoff Hugo, Ph.D. Department of Radiation Oncology Virginia Commonwealth University, Richmond, Virginia, USA Disclosures Research support: Philips

More information

Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines

Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines Martha M. Coselmon, a) James M. Balter, Daniel L. McShan, and Marc L. Kessler Department

More information

A Registration-Based Atlas Propagation Framework for Automatic Whole Heart Segmentation

A Registration-Based Atlas Propagation Framework for Automatic Whole Heart Segmentation A Registration-Based Atlas Propagation Framework for Automatic Whole Heart Segmentation Xiahai Zhuang (PhD) Centre for Medical Image Computing University College London Fields-MITACS Conference on Mathematics

More information

Auto-contouring the Prostate for Online Adaptive Radiotherapy

Auto-contouring the Prostate for Online Adaptive Radiotherapy Auto-contouring the Prostate for Online Adaptive Radiotherapy Yan Zhou 1 and Xiao Han 1 Elekta Inc., Maryland Heights, MO, USA yan.zhou@elekta.com, xiao.han@elekta.com, Abstract. Among all the organs under

More information

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC GPU applications in Cancer Radiation Therapy at UCSD Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC Conventional Radiotherapy SIMULATION: Construciton, Dij Days PLANNING:

More information

RIGID IMAGE REGISTRATION

RIGID IMAGE REGISTRATION RIGID IMAGE REGISTRATION Duygu Tosun-Turgut, Ph.D. Center for Imaging of Neurodegenerative Diseases Department of Radiology and Biomedical Imaging duygu.tosun@ucsf.edu What is registration? Image registration

More information

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha Model Generation from Multiple Volumes using Constrained Elastic SurfaceNets Michael E. Leventon and Sarah F. F. Gibson 1 MIT Artificial Intelligence Laboratory, Cambridge, MA 02139, USA leventon@ai.mit.edu

More information

How to simulate a volume-controlled flooding with mathematical morphology operators?

How to simulate a volume-controlled flooding with mathematical morphology operators? How to simulate a volume-controlled flooding with mathematical morphology operators? Serge Beucher To cite this version: Serge Beucher. How to simulate a volume-controlled flooding with mathematical morphology

More information

Use of Deformable Image Registration in Radiation Therapy. Colin Sims, M.Sc. Accuray Incorporated 1

Use of Deformable Image Registration in Radiation Therapy. Colin Sims, M.Sc. Accuray Incorporated 1 Use of Deformable Image Registration in Radiation Therapy Colin Sims, M.Sc. Accuray Incorporated 1 Overview of Deformable Image Registration (DIR) Algorithms that can deform one dataset to another have

More information

Lossless and Lossy Minimal Redundancy Pyramidal Decomposition for Scalable Image Compression Technique

Lossless and Lossy Minimal Redundancy Pyramidal Decomposition for Scalable Image Compression Technique Lossless and Lossy Minimal Redundancy Pyramidal Decomposition for Scalable Image Compression Technique Marie Babel, Olivier Déforges To cite this version: Marie Babel, Olivier Déforges. Lossless and Lossy

More information

Atlas Based Segmentation of the prostate in MR images

Atlas Based Segmentation of the prostate in MR images Atlas Based Segmentation of the prostate in MR images Albert Gubern-Merida and Robert Marti Universitat de Girona, Computer Vision and Robotics Group, Girona, Spain {agubern,marly}@eia.udg.edu Abstract.

More information

Registration by continuous optimisation. Stefan Klein Erasmus MC, the Netherlands Biomedical Imaging Group Rotterdam (BIGR)

Registration by continuous optimisation. Stefan Klein Erasmus MC, the Netherlands Biomedical Imaging Group Rotterdam (BIGR) Registration by continuous optimisation Stefan Klein Erasmus MC, the Netherlands Biomedical Imaging Group Rotterdam (BIGR) Registration = optimisation C t x t y 1 Registration = optimisation C t x t y

More information

Change Detection System for the Maintenance of Automated Testing

Change Detection System for the Maintenance of Automated Testing Change Detection System for the Maintenance of Automated Testing Miroslav Bures To cite this version: Miroslav Bures. Change Detection System for the Maintenance of Automated Testing. Mercedes G. Merayo;

More information

Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience

Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience DVH Estimates Creating a Knowledge Based Model using RapidPlan TM : The Henry Ford Experience Karen Chin Snyder, MS, DABR AAMD Region V Meeting October 4, 2014 Disclosures The Department of Radiation Oncology

More information

The Insight Toolkit. Image Registration Algorithms & Frameworks

The Insight Toolkit. Image Registration Algorithms & Frameworks The Insight Toolkit Image Registration Algorithms & Frameworks Registration in ITK Image Registration Framework Multi Resolution Registration Framework Components PDE Based Registration FEM Based Registration

More information

SDLS: a Matlab package for solving conic least-squares problems

SDLS: a Matlab package for solving conic least-squares problems SDLS: a Matlab package for solving conic least-squares problems Didier Henrion, Jérôme Malick To cite this version: Didier Henrion, Jérôme Malick. SDLS: a Matlab package for solving conic least-squares

More information

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis

Basic principles of MR image analysis. Basic principles of MR image analysis. Basic principles of MR image analysis Basic principles of MR image analysis Basic principles of MR image analysis Julien Milles Leiden University Medical Center Terminology of fmri Brain extraction Registration Linear registration Non-linear

More information

Prostate Detection Using Principal Component Analysis

Prostate Detection Using Principal Component Analysis Prostate Detection Using Principal Component Analysis Aamir Virani (avirani@stanford.edu) CS 229 Machine Learning Stanford University 16 December 2005 Introduction During the past two decades, computed

More information

Multi-Atlas Segmentation of the Cardiac MR Right Ventricle

Multi-Atlas Segmentation of the Cardiac MR Right Ventricle Multi-Atlas Segmentation of the Cardiac MR Right Ventricle Yangming Ou, Jimit Doshi, Guray Erus, and Christos Davatzikos Section of Biomedical Image Analysis (SBIA) Department of Radiology, University

More information

Medical Image Registration by Maximization of Mutual Information

Medical Image Registration by Maximization of Mutual Information Medical Image Registration by Maximization of Mutual Information EE 591 Introduction to Information Theory Instructor Dr. Donald Adjeroh Submitted by Senthil.P.Ramamurthy Damodaraswamy, Umamaheswari Introduction

More information

Biomedical Image Analysis based on Computational Registration Methods. João Manuel R. S. Tavares

Biomedical Image Analysis based on Computational Registration Methods. João Manuel R. S. Tavares Biomedical Image Analysis based on Computational Registration Methods João Manuel R. S. Tavares tavares@fe.up.pt, www.fe.up.pt/~tavares Outline 1. Introduction 2. Methods a) Spatial Registration of (2D

More information

Biomedical Imaging Registration Trends and Applications. Francisco P. M. Oliveira, João Manuel R. S. Tavares

Biomedical Imaging Registration Trends and Applications. Francisco P. M. Oliveira, João Manuel R. S. Tavares Biomedical Imaging Registration Trends and Applications Francisco P. M. Oliveira, João Manuel R. S. Tavares tavares@fe.up.pt, www.fe.up.pt/~tavares Outline 1. Introduction 2. Spatial Registration of (2D

More information

Using a Medical Thesaurus to Predict Query Difficulty

Using a Medical Thesaurus to Predict Query Difficulty Using a Medical Thesaurus to Predict Query Difficulty Florian Boudin, Jian-Yun Nie, Martin Dawes To cite this version: Florian Boudin, Jian-Yun Nie, Martin Dawes. Using a Medical Thesaurus to Predict Query

More information

HST.582J / 6.555J / J Biomedical Signal and Image Processing Spring 2007

HST.582J / 6.555J / J Biomedical Signal and Image Processing Spring 2007 MIT OpenCourseWare http://ocw.mit.edu HST.582J / 6.555J / 16.456J Biomedical Signal and Image Processing Spring 2007 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.

More information

Image Co-Registration II: TG132 Quality Assurance for Image Registration. Image Co-Registration II: TG132 Quality Assurance for Image Registration

Image Co-Registration II: TG132 Quality Assurance for Image Registration. Image Co-Registration II: TG132 Quality Assurance for Image Registration Image Co-Registration II: TG132 Quality Assurance for Image Registration Preliminary Recommendations from TG 132* Kristy Brock, Sasa Mutic, Todd McNutt, Hua Li, and Marc Kessler *Recommendations are NOT

More information

A Review on Label Image Constrained Multiatlas Selection

A Review on Label Image Constrained Multiatlas Selection A Review on Label Image Constrained Multiatlas Selection Ms. VAIBHAVI NANDKUMAR JAGTAP 1, Mr. SANTOSH D. KALE 2 1PG Scholar, Department of Electronics and Telecommunication, SVPM College of Engineering,

More information

The MSKCC Approach to IMRT. Outline

The MSKCC Approach to IMRT. Outline The MSKCC Approach to IMRT Spiridon V. Spirou, PhD Department of Medical Physics Memorial Sloan-Kettering Cancer Center New York, NY Outline Optimization Field splitting Delivery Independent verification

More information

Interactive Treatment Planning in Cancer Radiotherapy

Interactive Treatment Planning in Cancer Radiotherapy Interactive Treatment Planning in Cancer Radiotherapy Mohammad Shakourifar Giulio Trigila Pooyan Shirvani Ghomi Abraham Abebe Sarah Couzens Laura Noreña Wenling Shang June 29, 212 1 Introduction Intensity

More information

DSM GENERATION FROM STEREOSCOPIC IMAGERY FOR DAMAGE MAPPING, APPLICATION ON THE TOHOKU TSUNAMI

DSM GENERATION FROM STEREOSCOPIC IMAGERY FOR DAMAGE MAPPING, APPLICATION ON THE TOHOKU TSUNAMI DSM GENERATION FROM STEREOSCOPIC IMAGERY FOR DAMAGE MAPPING, APPLICATION ON THE TOHOKU TSUNAMI Cyrielle Guérin, Renaud Binet, Marc Pierrot-Deseilligny To cite this version: Cyrielle Guérin, Renaud Binet,

More information

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Computational Medical Imaging Analysis Chapter 4: Image Visualization Computational Medical Imaging Analysis Chapter 4: Image Visualization Jun Zhang Laboratory for Computational Medical Imaging & Data Analysis Department of Computer Science University of Kentucky Lexington,

More information

A Hybrid Method for Haemorrhage Segmentation in Trauma Brain CT

A Hybrid Method for Haemorrhage Segmentation in Trauma Brain CT SOLTANINEJAD ET AL.: HAEMORHAGE SEGMENTATION IN BRAIN CT 1 A Hybrid Method for Haemorrhage Segmentation in Trauma Brain CT Mohammadreza Soltaninejad 1 msoltaninejad@lincoln.ac.uk Tryphon Lambrou 1 tlambrou@lincoln.ac.uk

More information

An Experimental Assessment of the 2D Visibility Complex

An Experimental Assessment of the 2D Visibility Complex An Experimental Assessment of the D Visibility Complex Hazel Everett, Sylvain Lazard, Sylvain Petitjean, Linqiao Zhang To cite this version: Hazel Everett, Sylvain Lazard, Sylvain Petitjean, Linqiao Zhang.

More information

Additional file 1: Online Supplementary Material 1

Additional file 1: Online Supplementary Material 1 Additional file 1: Online Supplementary Material 1 Calyn R Moulton and Michael J House School of Physics, University of Western Australia, Crawley, Western Australia. Victoria Lye, Colin I Tang, Michele

More information

Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No.

Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132 Kristy K. Brock a) Department of Imaging Physics, The University

More information

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION Philips J. Res. 51 (1998) 197-201 FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION This special issue of Philips Journalof Research includes a number of papers presented at a Philips

More information

ANALYSIS OF PULMONARY FIBROSIS IN MRI, USING AN ELASTIC REGISTRATION TECHNIQUE IN A MODEL OF FIBROSIS: Scleroderma

ANALYSIS OF PULMONARY FIBROSIS IN MRI, USING AN ELASTIC REGISTRATION TECHNIQUE IN A MODEL OF FIBROSIS: Scleroderma ANALYSIS OF PULMONARY FIBROSIS IN MRI, USING AN ELASTIC REGISTRATION TECHNIQUE IN A MODEL OF FIBROSIS: Scleroderma ORAL DEFENSE 8 th of September 2017 Charlotte MARTIN Supervisor: Pr. MP REVEL M2 Bio Medical

More information

Nonrigid Registration using Free-Form Deformations

Nonrigid Registration using Free-Form Deformations Nonrigid Registration using Free-Form Deformations Hongchang Peng April 20th Paper Presented: Rueckert et al., TMI 1999: Nonrigid registration using freeform deformations: Application to breast MR images

More information

Multimodal Elastic Image Matching

Multimodal Elastic Image Matching Research results based on my diploma thesis supervised by Prof. Witsch 2 and in cooperation with Prof. Mai 3. 1 February 22 nd 2011 1 Karlsruhe Institute of Technology (KIT) 2 Applied Mathematics Department,

More information

3D Voxel-Based Volumetric Image Registration with Volume-View Guidance

3D Voxel-Based Volumetric Image Registration with Volume-View Guidance 3D Voxel-Based Volumetric Image Registration with Volume-View Guidance Guang Li*, Huchen Xie, Holly Ning, Deborah Citrin, Jacek Copala, Barbara Arora, Norman Coleman, Kevin Camphausen, and Robert Miller

More information

Virtual Phantoms for IGRT QA

Virtual Phantoms for IGRT QA TM Virtual Phantoms for IGRT QA Why ImSimQA? ImSimQA was developed to overcome the limitations of physical phantoms for testing modern medical imaging and radiation therapy software systems, when there

More information

Implementation of Advanced Image Guided Radiation Therapy

Implementation of Advanced Image Guided Radiation Therapy Image Acquisition Course Outline Principles, characteristics& applications of the available modalities Image Processing in the T x room Image guided treatment delivery What can / can t we do in the room

More information

Weed Leaf Recognition in Complex Natural Scenes by Model-Guided Edge Pairing

Weed Leaf Recognition in Complex Natural Scenes by Model-Guided Edge Pairing Weed Leaf Recognition in Complex Natural Scenes by Model-Guided Edge Pairing Benoit De Mezzo, Gilles Rabatel, Christophe Fiorio To cite this version: Benoit De Mezzo, Gilles Rabatel, Christophe Fiorio.

More information

Deformable Image Registration, Contour Propagation and Dose Mapping: 101 and 201. Please do not (re)redistribute

Deformable Image Registration, Contour Propagation and Dose Mapping: 101 and 201. Please do not (re)redistribute Deformable Registration, Contour Deformable Registration, Contour Propagation and Dose Mapping: 101 and 201 Marc Kessler, PhD The University of Michigan Jean Pouliot, PhD University of California Learning

More information

Spectral Active Clustering of Remote Sensing Images

Spectral Active Clustering of Remote Sensing Images Spectral Active Clustering of Remote Sensing Images Zifeng Wang, Gui-Song Xia, Caiming Xiong, Liangpei Zhang To cite this version: Zifeng Wang, Gui-Song Xia, Caiming Xiong, Liangpei Zhang. Spectral Active

More information

State-of-the-Art IGRT

State-of-the-Art IGRT in partnership with State-of-the-Art IGRT Exploring the Potential of High-Precision Dose Delivery and Real-Time Knowledge of the Target Volume Location Antje-Christin Knopf IOP Medical Physics Group Scientific

More information

CHAPTER 2. Morphometry on rodent brains. A.E.H. Scheenstra J. Dijkstra L. van der Weerd

CHAPTER 2. Morphometry on rodent brains. A.E.H. Scheenstra J. Dijkstra L. van der Weerd CHAPTER 2 Morphometry on rodent brains A.E.H. Scheenstra J. Dijkstra L. van der Weerd This chapter was adapted from: Volumetry and other quantitative measurements to assess the rodent brain, In vivo NMR

More information

Methods for data preprocessing

Methods for data preprocessing Methods for data preprocessing John Ashburner Wellcome Trust Centre for Neuroimaging, 12 Queen Square, London, UK. Overview Voxel-Based Morphometry Morphometry in general Volumetrics VBM preprocessing

More information

Motion-based obstacle detection and tracking for car driving assistance

Motion-based obstacle detection and tracking for car driving assistance Motion-based obstacle detection and tracking for car driving assistance G. Lefaix, E. Marchand, Patrick Bouthemy To cite this version: G. Lefaix, E. Marchand, Patrick Bouthemy. Motion-based obstacle detection

More information

STIC AmSud Project. Graph cut based segmentation of cardiac ventricles in MRI: a shape-prior based approach

STIC AmSud Project. Graph cut based segmentation of cardiac ventricles in MRI: a shape-prior based approach STIC AmSud Project Graph cut based segmentation of cardiac ventricles in MRI: a shape-prior based approach Caroline Petitjean A joint work with Damien Grosgeorge, Pr Su Ruan, Pr JN Dacher, MD October 22,

More information

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR Sean Gill a, Purang Abolmaesumi a,b, Siddharth Vikal a, Parvin Mousavi a and Gabor Fichtinger a,b,* (a) School of Computing, Queen

More information

MR IMAGE SEGMENTATION

MR IMAGE SEGMENTATION MR IMAGE SEGMENTATION Prepared by : Monil Shah What is Segmentation? Partitioning a region or regions of interest in images such that each region corresponds to one or more anatomic structures Classification

More information

Automatic Multi-Atlas Segmentation of Myocardium with SVF-Net

Automatic Multi-Atlas Segmentation of Myocardium with SVF-Net Automatic Multi-Atlas Segmentation of Myocardium with SVF-Net Marc-Michel Rohé, Maxime Sermesant, Xavier Pennec To cite this version: Marc-Michel Rohé, Maxime Sermesant, Xavier Pennec. Automatic Multi-Atlas

More information

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT CLINICAL COMMISSIONING AND ACCEPTANCE TESTING OF A 3D SURFACE MATCHING SYSTEM Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago Learning Objective Describe acceptance

More information

Where are we now? Structural MRI processing and analysis

Where are we now? Structural MRI processing and analysis Where are we now? Structural MRI processing and analysis Pierre-Louis Bazin bazin@cbs.mpg.de Leipzig, Germany Structural MRI processing: why bother? Just use the standards? SPM FreeSurfer FSL However:

More information

Robust IP and UDP-lite header recovery for packetized multimedia transmission

Robust IP and UDP-lite header recovery for packetized multimedia transmission Robust IP and UDP-lite header recovery for packetized multimedia transmission Michel Kieffer, François Mériaux To cite this version: Michel Kieffer, François Mériaux. Robust IP and UDP-lite header recovery

More information

A Study of Medical Image Analysis System

A Study of Medical Image Analysis System Indian Journal of Science and Technology, Vol 8(25), DOI: 10.17485/ijst/2015/v8i25/80492, October 2015 ISSN (Print) : 0974-6846 ISSN (Online) : 0974-5645 A Study of Medical Image Analysis System Kim Tae-Eun

More information

4D CT scan Generation of Lung from Physical Simulation of Pulmonary Motion

4D CT scan Generation of Lung from Physical Simulation of Pulmonary Motion 4D CT scan Generation of Lung from Physical Simulation of Pulmonary Motion Pierre-Frédéric Villard, Michaël Beuve, Behzad Shariat To cite this version: Pierre-Frédéric Villard, Michaël Beuve, Behzad Shariat.

More information

A Voronoi-Based Hybrid Meshing Method

A Voronoi-Based Hybrid Meshing Method A Voronoi-Based Hybrid Meshing Method Jeanne Pellerin, Lévy Bruno, Guillaume Caumon To cite this version: Jeanne Pellerin, Lévy Bruno, Guillaume Caumon. A Voronoi-Based Hybrid Meshing Method. 2012. hal-00770939

More information

Regularization parameter estimation for non-negative hyperspectral image deconvolution:supplementary material

Regularization parameter estimation for non-negative hyperspectral image deconvolution:supplementary material Regularization parameter estimation for non-negative hyperspectral image deconvolution:supplementary material Yingying Song, David Brie, El-Hadi Djermoune, Simon Henrot To cite this version: Yingying Song,

More information

Attribute Similarity and Mutual-Saliency Weighting for Registration and Label Fusion

Attribute Similarity and Mutual-Saliency Weighting for Registration and Label Fusion Attribute Similarity and Mutual-Saliency Weighting for Registration and Label Fusion Yangming Ou, Jimit Doshi, Guray Erus, and Christos Davatzikos Section of Biomedical Image Analysis (SBIA) Department

More information

Estimating 3D Respiratory Motion from Orbiting Views

Estimating 3D Respiratory Motion from Orbiting Views Estimating 3D Respiratory Motion from Orbiting Views Rongping Zeng, Jeffrey A. Fessler, James M. Balter The University of Michigan Oct. 2005 Funding provided by NIH Grant P01 CA59827 Motivation Free-breathing

More information

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration

iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration iplan RT Image Advanced Contouring Workstation - Driving Physician Collaboration The iplan Contouring Workstation offers unique and innovative capabilities for faster contouring and consistent segmentation

More information

Image Guidance and Beam Level Imaging in Digital Linacs

Image Guidance and Beam Level Imaging in Digital Linacs Image Guidance and Beam Level Imaging in Digital Linacs Ruijiang Li, Ph.D. Department of Radiation Oncology Stanford University School of Medicine 2014 AAPM Therapy Educational Course Disclosure Research

More information

Comparator: A Tool for Quantifying Behavioural Compatibility

Comparator: A Tool for Quantifying Behavioural Compatibility Comparator: A Tool for Quantifying Behavioural Compatibility Meriem Ouederni, Gwen Salaün, Javier Cámara, Ernesto Pimentel To cite this version: Meriem Ouederni, Gwen Salaün, Javier Cámara, Ernesto Pimentel.

More information

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending 3DVH : On The Accuracy Of The Planned Dose Perturbation Algorithm SUN NUCLEAR corporation Your Most Valuable QA and Dosimetry Tools *Patent Pending introduction State-of-the-art IMRT QA of static gantry

More information

Dense Hough transforms on gray level images using multi-scale derivatives

Dense Hough transforms on gray level images using multi-scale derivatives Dense Hough transforms on gray level images using multi-scale derivatives Antoine Manzanera To cite this version: Antoine Manzanera. Dense Hough transforms on gray level images using multi-scale derivatives.

More information