FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION
|
|
- Candace Long
- 5 years ago
- Views:
Transcription
1 Philips J. Res. 51 (1998) FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION This special issue of Philips Journalof Research includes a number of papers presented at a Philips internal workshop on Motion Detection and Motion Compensation*. The meeting brought together Philips scientists of different disciplines working in the field of motion analysis for image processing applications. The interest in motion detection based on medical and technical image scenes from different image sensors is continuously growing. This is mainly due to the fact that an increasing number of faster imaging techniques allow for real-time applications where motion plays an increasingly more important role. In the medical segment, such applications can be found in fluoroscopic image sequences for digital subtraction angiographies (DSA), portal images from radiotherapy, and magnetic resonance imaging (MRI) as well as computer tomography (CT) image series. In the consumer segment, a large number of algorithms based on motion detection lead to improved television and video applications. In the professional segment, many computer vision and robot vision applications are inconceivable without motion detection. Figure 1 gives an overview of the application fields. The bold-printed number in some of the boxes refers to the respective paper in this issue. An example from the medical segment, which was the main focus of the workshop, is DSA, a standard diagnosis tool for the examination of blood vessels. With this method, X-ray images are taken from the patient, while a radio-opaque contrast agent is injected through a catheter. The first image is usually taken before injection, and is called the mask image. In the case of patient motion between mask and contrasted images, artifacts appear in the subtraction result. These artifacts can be significantly reduced by motion detection and subsequent compensation which then leads to an improved diagnosis. Another medical example is given by radiotherapy. Linear accelerator devices produce images that are called portal images. These portal images can be used for motion tracking. Tracking of patient motion during the radiotherapy treatment is very important for automatic accelerator control because the device must be immediately switched off when the patient leaves the optimal position. * Held at Philips Research Laboratories Hamburg, Germany in June Philips Journal of Research Vol. SI No
2 Fig. I. Overview of the application fields of motion detection. The bold-printed numbers refer to the numbered papers in this issue. If the patient is at rest, motion detection can also be used to track surgical instruments such as catheters, and biopsy needles within minimally invasive procedures which are monitored via CT, M RI or X-ray fluoroscopy devices. Since pre-operatively acquired images are necessary for navigation during such procedures, these images must be related to the patient's coordinate system in the operating room or to an intra-operatively acquired image. In the case of patient movements during treatment (e.g. due to heart beat and breathing), patient movement must be tracked, and the registration must be updated. In real-time applications a compromise is to be found between signal-tonoise ratio (SNR) and temporal resolution. In recent years, for instance, M RI has shown that real-time applications are possible. However, the main drawback of the required fast pulse sequences is the low SNR of the MR-images. In such situations the use of a radial MR-acquisition scheme 198 Philips Journalof Research Vol. SI NO
3 can support the concept ofhierarchical motion estimation in image sequences, which can be utilized for the Correlative Averaging noise-reduction strategy. In addition to the real-time aspect, dose reduction is a general goal in X-ray based medical imaging (fluoroscopy and CT). One example is real-time fluoroscopic visual guidance in diagnostic examinations and therapeutic interventions. The resulting moving images are viewed on-line on a monitor while the clinical procedure is performed. Patient and medical staff are therefore exposed to more radiation than in classical single-shot radiographic imaging. In these situations, low-dose rates are desired, and this becomes possible with the use of motion-compensated filtering. In the technical area, motion detection is also used in many application fields, particularly in television and video systems. Prominent examples of the consumer segment are picture rate conversion, coding and image compression, as well as noise reduction, In the professional computer- and robot vision segment motion tracking finds a huge variety of applications. Flow visualization and analysis (automatic extraction of velocity fields to study turbulence via particle tracking), matching of satellite image sequences, object-tracking in street scenes, and remote velocity measurement to control autonomous vehicles and robots are only a few examples that underline the importance of motion detection. The methods for motion detection are surprisingly similar for all the abovementioned applications. Generally, motion is associated with changes in the images. Hence, corresponding features ofthe object in motion have to be identified in the image sequence. Such features can be external artificial markers attached to the object, or intrinsic object-related image features like edges and corners. However, the most frequently used feature is the gray-value of the object itself, because motion-induced gray-value changes can be quantified in terms of similarity measures. Nevertheless, the similarity measure has to be carefully adapted to image-sensor characteristics to yield acceptable results. The first paper of this special issue, 'Motion Detection and Motion Compensation for Digital Subtraction Angiography Image Enhancement' by Buzug, Weese and Strasters (paper 1), focuses on artifact suppression in subtraction imaging. Special emphasis is given to the analysis of similarity measures that are used for motion detection. This is done because image pairs in digital subtraction angiography are inherently dissimilar and an adequate similarity measure must be adapted to that situation. In the second paper, 'Bayesian Motion Estimation for Temporally Recursive Noise Reduction in X-Ray Fluoroscopy' by Aach and Kunz (paper 2), the authors focus on a robust motion estimator which is able to deal with the high noise levels Philips Journal of Research Vol. SI No
4 encountered in low-dose fluoroscopy images. This robustness against noise is achieved by spatial and temporal regularization. In the paper 'Layered Motion Estimation' by Schutten, Pelagotti and de Haan (paper 3), a region based motion-parameter estimation and segmentation algorithm is proposed that permits quasi-simultaneous motion estimation up to a fixed maximum number ofmoving layers within a sequence. The concept yields a very simple approach to the total motion estimation problem, and results in a very low operationsper-pixel-count. A variant of the presented algorithm is scheduled to run in real-time on a Philips TMIOOOprocessor. The paper 'Correlative Averaging for Magnetic Resonance Imaging' by Schäffter, Carlsen and Rasche (paper 4) deals with a hierarchical block matching procedure for motion detection in Magnetic Resonance Imaging (MRI). The determined displacement fields can be used in a Correlative Averaging approach to increase the SNR and in the reconstruction process to reduce motion artifacts. In the paper 'A Projection-Based Method for Motion-Compensated Noise Suppression' by GraB, Rasche, Lüdeke, Pro ksa and Schäffter (paper 5), a projection-based method for the motion-compensated SNR enhancement in radial MR imaging is presented. Since motion of an object is represented in the radial projections used for the reconstruction, a motion-compensated noise suppression method can already be applied to the measured projections. The next two papers deal with motion detection or registration of pretreatment with intra-treatment images. The paper '2D/3D Registration and Motion Tracking for Surgical Interventions' by Weese, Buzug, Penney and Desmedt (paper 6) focuses on the problem of registration of intra-operatively acquired X-ray fluoroscopies with 3D CT images obtained before the intervention. The result can be used to support the placement of pedicle screws in spine surgery as well as to guide the installment of stents in Transfemoral Endovascular Aneurysm Management (TEAM). The different approaches for 2D/3D registration are discussed and a novel voxel-based method is presented. The paper 'A Structure-Based Method for on-line Matching of Port al Images for an Optimal Patient Set-up in Radiotherapy' by Kreuder, Schreiber, Kausch and Dössel (paper 7) describes the registration problem in radiotherapy. Portal images are used to ensure a correct position of the patient relative to the beam during every radiation session. A reliable on-line verification is of clinical interest to interrupt the treatment in time if the patient is not at the desired position. The authors present a structure-based method which is almost insensitive to disturbances. Motion of the patient on the treatment table can then be detected fast and reliably. Another approach of motion artifact reduction is given in the paper 'Real- Time Reduction of Motion Artefacts Using k-space Weighting in Magnetic 200 Philips Journal of Research Vol. SI No
5 Resonance Imaging' by Sinkus and Börnert (paper 8). Since respiratory motion in abdominal MRI gives rise to motion artifacts, the authors merge the benefits of the so-called Diminishing Variance Algorithm (DVA) concept with the ideas of Motion-Adapted Gating (MAG). In contrast to the other methods mentioned above, motion artifacts are reduced within the image acquisition process. I would like to acknowledge all the parties who contributed to the success of the workshop. Especially, I would like to thank Ursula Muuss for secretarial support and the service group of the laboratory. I would also like to thank all the reviewers from Philips Research Hamburg for their valuable help in the reviewing process. Last but not least, I would like to thank all our customers, whose kind support made the results reported in this special issue possible. Thorsten M. Buzug Medical Image Processing T.Buzug@pjh.research.philips.com Philips Journalof Research Vol. SI No
SIGMI Meeting ~Image Fusion~ Computer Graphics and Visualization Lab Image System Lab
SIGMI Meeting ~Image Fusion~ Computer Graphics and Visualization Lab Image System Lab Introduction Medical Imaging and Application CGV 3D Organ Modeling Model-based Simulation Model-based Quantification
More informationA PROJECTION-BASED METHOD FOR MOTION-COMPENSATED NOISE SUPPRESSION
Philips J. Res. 51 (1998) 283-298 A PROJECTION-BASED METHOD FOR MOTION-COMPENSATED NOISE SUPPRESSION by M. GRASS, V. RASCHE, K.M. LÜDEKE, R. PROKSA and T. SCHÄFFTER Philips Research Division Technical
More informationLecture 6: Medical imaging and image-guided interventions
ME 328: Medical Robotics Winter 2019 Lecture 6: Medical imaging and image-guided interventions Allison Okamura Stanford University Updates Assignment 3 Due this Thursday, Jan. 31 Note that this assignment
More informationGuide wire tracking in interventional radiology
Guide wire tracking in interventional radiology S.A.M. Baert,W.J. Niessen, E.H.W. Meijering, A.F. Frangi, M.A. Viergever Image Sciences Institute, University Medical Center Utrecht, rm E 01.334, P.O.Box
More informationMedical Images Analysis and Processing
Medical Images Analysis and Processing - 25642 Emad Course Introduction Course Information: Type: Graduated Credits: 3 Prerequisites: Digital Image Processing Course Introduction Reference(s): Insight
More informationA preliminary study on adaptive field-of-view tracking in peripheral digital subtraction angiography
Journal of X-Ray Science and Technology 11 (2003) 149 159 149 IOS Press A preliminary study on adaptive field-of-view tracking in peripheral digital subtraction angiography James R. Bennett a,b,er-weibai
More informationComputational Medical Imaging Analysis
Computational Medical Imaging Analysis Chapter 1: Introduction to Imaging Science Jun Zhang Laboratory for Computational Medical Imaging & Data Analysis Department of Computer Science University of Kentucky
More informationImage Acquisition Systems
Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS
More informationArtefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT
Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT Marcus Brehm 1,2, Thorsten Heußer 1, Pascal Paysan 3, Markus Oehlhafen 3, and Marc Kachelrieß 1,2 1 German Cancer Research Center
More informationNon-rigid 2D-3D image registration for use in Endovascular repair of Abdominal Aortic Aneurysms.
RAHEEM ET AL.: IMAGE REGISTRATION FOR EVAR IN AAA. 1 Non-rigid 2D-3D image registration for use in Endovascular repair of Abdominal Aortic Aneurysms. Ali Raheem 1 ali.raheem@kcl.ac.uk Tom Carrell 2 tom.carrell@gstt.nhs.uk
More informationRespiratory Motion Compensation for C-arm CT Liver Imaging
Respiratory Motion Compensation for C-arm CT Liver Imaging Aline Sindel 1, Marco Bögel 1,2, Andreas Maier 1,2, Rebecca Fahrig 3, Joachim Hornegger 1,2, Arnd Dörfler 4 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg
More informationClinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis
Clinical Importance Rapid cardiovascular flow quantitation using sliceselective Fourier velocity encoding with spiral readouts Valve disease affects 10% of patients with heart disease in the U.S. Most
More informationIntraoperative Prostate Tracking with Slice-to-Volume Registration in MR
Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR Sean Gill a, Purang Abolmaesumi a,b, Siddharth Vikal a, Parvin Mousavi a and Gabor Fichtinger a,b,* (a) School of Computing, Queen
More information3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations
3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations Martin Groher 2, Frederik Bender 1, Ali Khamene 3, Wolfgang Wein 3, Tim Hauke Heibel 2, Nassir Navab 2 1 Siemens
More informationA Study of Medical Image Analysis System
Indian Journal of Science and Technology, Vol 8(25), DOI: 10.17485/ijst/2015/v8i25/80492, October 2015 ISSN (Print) : 0974-6846 ISSN (Online) : 0974-5645 A Study of Medical Image Analysis System Kim Tae-Eun
More informationMotion Artifacts and Suppression in MRI At a Glance
Motion Artifacts and Suppression in MRI At a Glance Xiaodong Zhong, PhD MR R&D Collaborations Siemens Healthcare MRI Motion Artifacts and Suppression At a Glance Outline Background Physics Common Motion
More information3D Radial Undersampling 7/19/2012. Artifact Removal SNR Restoration-- HYPR. Background: Time Resolved MR Angiography 4D DSA AND 4D FLUOROSCOPY:
4D DSA AND 4D FLUOROSCOPY: Accelerated Applications using Undersampled Acquisition and Constrained Reconstruction Background: Time Resolved MR Angiography During the past 12 years we have been investigating
More informationFreehand 3-D Sonographic Measurement of the Superficial Femoral Artery
Freehand 3-D Sonographic Measurement of the Superficial Femoral Artery Dennis Sandkühler, Christian Sobotta, Matthias Samsel, Heinrich Martin Overhoff Medical Engineering Laboratory, University of Applied
More informationRADIOMICS: potential role in the clinics and challenges
27 giugno 2018 Dipartimento di Fisica Università degli Studi di Milano RADIOMICS: potential role in the clinics and challenges Dr. Francesca Botta Medical Physicist Istituto Europeo di Oncologia (Milano)
More informationImprovement and Evaluation of a Time-of-Flight-based Patient Positioning System
Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System Simon Placht, Christian Schaller, Michael Balda, André Adelt, Christian Ulrich, Joachim Hornegger Pattern Recognition Lab,
More informationImage Guidance and Beam Level Imaging in Digital Linacs
Image Guidance and Beam Level Imaging in Digital Linacs Ruijiang Li, Ph.D. Department of Radiation Oncology Stanford University School of Medicine 2014 AAPM Therapy Educational Course Disclosure Research
More informationUniversity College London, Gower Street, London, UK, WC1E 6BT {g.gao, s.tarte, p.chinchapatnam, d.hill,
Validation of the use of photogrammetry to register preprocedure MR images to intra-procedure patient position for image-guided cardiac catheterization procedures Gang Gao 1, Segolene Tarte 1, Andy King
More informationRespiratory Motion Estimation using a 3D Diaphragm Model
Respiratory Motion Estimation using a 3D Diaphragm Model Marco Bögel 1,2, Christian Riess 1,2, Andreas Maier 1, Joachim Hornegger 1, Rebecca Fahrig 2 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg 2
More informationAssessing Accuracy Factors in Deformable 2D/3D Medical Image Registration Using a Statistical Pelvis Model
Assessing Accuracy Factors in Deformable 2D/3D Medical Image Registration Using a Statistical Pelvis Model Jianhua Yao National Institute of Health Bethesda, MD USA jyao@cc.nih.gov Russell Taylor The Johns
More informationCombination of Markerless Surrogates for Motion Estimation in Radiation Therapy
Combination of Markerless Surrogates for Motion Estimation in Radiation Therapy CARS 2016 T. Geimer, M. Unberath, O. Taubmann, C. Bert, A. Maier June 24, 2016 Pattern Recognition Lab (CS 5) FAU Erlangen-Nu
More informationGradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay
Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay Jian Wang, Anja Borsdorf, Benno Heigl, Thomas Köhler, Joachim Hornegger Pattern Recognition Lab, Friedrich-Alexander-University
More informationAutomatic DRR Enhancement for Patient Positioning in a Radiotherapy Treatment
Automatic DRR Enhancement for Patient Positioning in a Radiotherapy Treatment Rafael Verdú-Monedero, Jorge Larrey-Ruiz, Juan Morales-Sánchez, José Luis Sancho-Gómez Department of Information Technologies
More informationA Navigation System for Minimally Invasive Abdominal Intervention Surgery Robot
A Navigation System for Minimally Invasive Abdominal Intervention Surgery Robot Weiming ZHAI, Yannan ZHAO and Peifa JIA State Key Laboratory of Intelligent Technology and Systems Tsinghua National Laboratory
More informationA Novel 2D-3D Registration Algorithm for Aligning Fluoro Images with 3D Pre-op CT/MR Images
A Novel 2D-3D Registration Algorithm for Aligning Fluoro Images with 3D Pre-op CT/MR Images Hari Sundar* 1, 2, Ali Khamene 1, Chenyang Xu 1, Frank Sauer 1, Christos Davatzikos 2 1 Siemens Corporate Research,
More informationMotion Compensation from Short-Scan Data in Cardiac CT
Motion Compensation from Short-Scan Data in Cardiac CT Juliane Hahn 1,2, Thomas Allmendinger 1, Herbert Bruder 1, and Marc Kachelrieß 2 1 Siemens Healthcare GmbH, Forchheim, Germany 2 German Cancer Research
More informationIncorporation of Prior Knowledge for Region of Change Imaging from Sparse Scan Data in Image-Guided Surgery
Incorporation of Prior Knowledge for Region of Change Imaging from Sparse Scan Data in Image-Guided Surgery J. Lee a, J. W. Stayman b, Y. Otake c, S. Schafer b, W. Zbijewski b, A. J. Khanna b,d, J. L.
More informationWhite Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space
White Pixel Artifact Caused by a noise spike during acquisition Spike in K-space sinusoid in image space Susceptibility Artifacts Off-resonance artifacts caused by adjacent regions with different
More informationCURRICULUM COMMITTEE MEETING Friday, March 18, :00 p.m. Student Life Center, Faculty Dining Room (Building 23, First Floor) AGENDA
CURRICULUM COMMITTEE MEETING Friday, March 18, 2016-2:00 p.m. Student Life Center, Faculty Dining Room (Building 23, First Floor) I. Call to Order AGENDA II. Roll Call III. Minutes of meeting of January
More informationRespiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data
Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data Christopher M Rank 1, Thorsten Heußer 1, Andreas Wetscherek 1, and Marc Kachelrieß 1 1 German Cancer
More informationNavigation System for ACL Reconstruction Using Registration between Multi-Viewpoint X-ray Images and CT Images
Navigation System for ACL Reconstruction Using Registration between Multi-Viewpoint X-ray Images and CT Images Mamoru Kuga a*, Kazunori Yasuda b, Nobuhiko Hata a, Takeyoshi Dohi a a Graduate School of
More information7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT
CLINICAL COMMISSIONING AND ACCEPTANCE TESTING OF A 3D SURFACE MATCHING SYSTEM Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago Learning Objective Describe acceptance
More informationAnalysis of 4D CT cine images for the characterization of organ motion due to breathing
-243- Analysis of 4D CT cine images for the characterization of organ motion due to breathing Maria Francesca Spadea 1,2, Marta Peroni 2, Marco Riboldi 2, Guido Baroni 2, George TY Chen 3, Gregory Sharp
More informationReal-time self-calibration of a tracked augmented reality display
Real-time self-calibration of a tracked augmented reality display Zachary Baum, Andras Lasso, Tamas Ungi, Gabor Fichtinger Laboratory for Percutaneous Surgery, Queen s University, Kingston, Canada ABSTRACT
More informationModule 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.
MRES 7005 - Fast Imaging Techniques Module 5: Dynamic Imaging and Phase Sharing (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review Improving Temporal Resolution True-FISP (I) True-FISP (II) Keyhole
More informationTomographic Reconstruction
Tomographic Reconstruction 3D Image Processing Torsten Möller Reading Gonzales + Woods, Chapter 5.11 2 Overview Physics History Reconstruction basic idea Radon transform Fourier-Slice theorem (Parallel-beam)
More informationOptical Guidance. Sanford L. Meeks. July 22, 2010
Optical Guidance Sanford L. Meeks July 22, 2010 Optical Tracking Optical tracking is a means of determining in real-time the position of a patient relative to the treatment unit. Markerbased systems track
More informationAccelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing
Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing Peng Hu, Ph.D. Associate Professor Department of Radiological Sciences PengHu@mednet.ucla.edu 310-267-6838 MRI... MRI has low
More informationRetrospective Spiral Respiratory Correlated Imaging with Varian RPM
Retrospective Spiral Respiratory Correlated Imaging with Varian RPM This is a Quick Step Guide for Retrospective Spiral Respiratory Correlated Imaging (4D CT) using the Varian RPM device v1.7 with the
More informationUse of MRI in Radiotherapy: Technical Consideration
Use of MRI in Radiotherapy: Technical Consideration Yanle Hu, PhD Department of Radiation Oncology, Mayo Clinic Arizona 04/07/2018 2015 MFMER slide-1 Conflict of Interest: None 2015 MFMER slide-2 Objectives
More informationAbbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology
Abbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology Outline High Spectral and Spatial Resolution MR Imaging (HiSS) What it is How to do it Ways to use it HiSS for Radiation
More informationUNIVERSITY OF SOUTHAMPTON
UNIVERSITY OF SOUTHAMPTON PHYS2007W1 SEMESTER 2 EXAMINATION 2014-2015 MEDICAL PHYSICS Duration: 120 MINS (2 hours) This paper contains 10 questions. Answer all questions in Section A and only two questions
More information3D/2D Model-to-Image Registration Applied to TIPS Surgery
3D/2D Model-to-Image Registration Applied to TIPS Surgery Julien Jomier 1, Elizabeth Bullitt 2, Mark Van Horn 2, Chetna Pathak 2, and Stephen R. Aylward 1 1 Kitware Inc. 28 Corporate Drive Clifton Park,
More informationGlobal Journal of Engineering Science and Research Management
ADVANCED K-MEANS ALGORITHM FOR BRAIN TUMOR DETECTION USING NAIVE BAYES CLASSIFIER Veena Bai K*, Dr. Niharika Kumar * MTech CSE, Department of Computer Science and Engineering, B.N.M. Institute of Technology,
More informationAn Endoscope With 2 DOFs Steering of Coaxial Nd:YAG Laser Beam for Fetal Surgery [Yamanaka et al. 2010, IEEE trans on Mechatronics]
An Endoscope With 2 DOFs Steering of Coaxial Nd:YAG Laser Beam for Fetal Surgery [Yamanaka et al. 2010, IEEE trans on Mechatronics] GEORGE DWYER Automatic Tracking Algorithm in Coaxial Near-infrared Laser
More informationMech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University
Mech. Engineering, Comp. Science, and Rad. Oncology Departments Schools of Engineering and Medicine, Bio-X Program, Stanford University 1 Conflict of Interest Nothing to disclose 2 Imaging During Beam
More informationOptimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago
Optimization of CT Simulation Imaging Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT imaging Goal: Achieve image quality that allows to perform the task at hand (diagnostic
More informationDigital Volume Correlation for Materials Characterization
19 th World Conference on Non-Destructive Testing 2016 Digital Volume Correlation for Materials Characterization Enrico QUINTANA, Phillip REU, Edward JIMENEZ, Kyle THOMPSON, Sharlotte KRAMER Sandia National
More informationChapter 3 Set Redundancy in Magnetic Resonance Brain Images
16 Chapter 3 Set Redundancy in Magnetic Resonance Brain Images 3.1 MRI (magnetic resonance imaging) MRI is a technique of measuring physical structure within the human anatomy. Our proposed research focuses
More informationClassification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging
1 CS 9 Final Project Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging Feiyu Chen Department of Electrical Engineering ABSTRACT Subject motion is a significant
More informationMarcel Worring Intelligent Sensory Information Systems
Marcel Worring worring@science.uva.nl Intelligent Sensory Information Systems University of Amsterdam Information and Communication Technology archives of documentaries, film, or training material, video
More informationCT Protocol Review: Practical Tips for the Imaging Physicist Physicist
CT Protocol Review: Practical Tips for the Imaging Physicist Physicist Dianna Cody, Ph.D., DABR, FAAPM U.T.M.D. Anderson Cancer Center August 8, 2013 AAPM Annual Meeting Goals Understand purpose and importance
More informationBACKGROUND MODELS FOR TRACKING OBJECTS UNDER WATER
Available Online at www.ijcsmc.com International Journal of Computer Science and Mobile Computing A Monthly Journal of Computer Science and Information Technology ISSN 2320 088X IMPACT FACTOR: 5.258 IJCSMC,
More informationMR Advance Techniques. Vascular Imaging. Class III
MR Advance Techniques Vascular Imaging Class III 1 Vascular Imaging There are several methods that can be used to evaluate the cardiovascular systems with the use of MRI. MRI will aloud to evaluate morphology
More information7/31/ D Cone-Beam CT: Developments and Applications. Disclosure. Outline. I have received research funding from NIH and Varian Medical System.
4D Cone-Beam CT: Developments and Applications Lei Ren, PhD, DABR Department of Radiation Oncology Duke University Medical Center Disclosure I have received research funding from NIH and Varian Medical
More informationState-of-the-Art IGRT
in partnership with State-of-the-Art IGRT Exploring the Potential of High-Precision Dose Delivery and Real-Time Knowledge of the Target Volume Location Antje-Christin Knopf IOP Medical Physics Group Scientific
More informationModel-Based Validation of a Graphics Processing Unit Algorithm to Track Foot Bone Kinematics Using Fluoroscopy
Model-Based Validation of a Graphics Processing Unit Algorithm to Track Foot Bone Kinematics Using Fluoroscopy Matthew Kindig, MS 1, Grant Marchelli, PhD 2, Joseph M. Iaquinto, PhD 1,2, Duane Storti, PhD
More informationDeviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies
g Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies Presented by Adam Kesner, Ph.D., DABR Assistant Professor, Division of Radiological Sciences,
More informationAn Improved Tracking Technique for Assessment of High Resolution Dynamic Radiography Kinematics
Copyright c 2008 ICCES ICCES, vol.8, no.2, pp.41-46 An Improved Tracking Technique for Assessment of High Resolution Dynamic Radiography Kinematics G. Papaioannou 1, C. Mitrogiannis 1 and G. Nianios 1
More informationREAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT
REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT Anand P Santhanam Assistant Professor, Department of Radiation Oncology OUTLINE Adaptive radiotherapy for head and
More informationFunctional MRI in Clinical Research and Practice Preprocessing
Functional MRI in Clinical Research and Practice Preprocessing fmri Preprocessing Slice timing correction Geometric distortion correction Head motion correction Temporal filtering Intensity normalization
More informationUvA-DARE (Digital Academic Repository) Motion compensation for 4D PET/CT Kruis, M.F. Link to publication
UvA-DARE (Digital Academic Repository) Motion compensation for 4D PET/CT Kruis, M.F. Link to publication Citation for published version (APA): Kruis, M. F. (2014). Motion compensation for 4D PET/CT General
More informationModel-Based Respiratory Motion Compensation for Image-Guided Cardiac Interventions
Model-Based Respiratory Motion Compensation for Image-Guided Cardiac Interventions February 8 Matthias Schneider Pattern Recognition Lab Friedrich-Alexander-University Erlangen-Nuremberg Imaging and Visualization
More informationVisualisation : Lecture 1. So what is visualisation? Visualisation
So what is visualisation? UG4 / M.Sc. Course 2006 toby.breckon@ed.ac.uk Computer Vision Lab. Institute for Perception, Action & Behaviour Introducing 1 Application of interactive 3D computer graphics to
More informationRAD. Experiences Using the Wireless FPD-Equipped MobileDaRt Evolution and Its Usefulness. 1. Introduction
RAD Experiences Using the Wireless FPD-Equipped MobileDaRt Evolution and Its Usefulness Department of Radiological Technology, Kitasato University Kitasato Institute Medical Center Hospital Satoshi Yanagita
More informationESTIMATING 3D DEFORMABLE MOTION FROM A SERIES OF FAST 2D MRI IMAGES. Jason M. Brown. Chapel Hill 2016
ESTIMATING 3D DEFORMABLE MOTION FROM A SERIES OF FAST 2D MRI IMAGES Jason M. Brown A thesis submitted to the faculty of the University of North Carolina at Chapel Hill in partial fulfillment of the requirements
More informationSPM8 for Basic and Clinical Investigators. Preprocessing
SPM8 for Basic and Clinical Investigators Preprocessing fmri Preprocessing Slice timing correction Geometric distortion correction Head motion correction Temporal filtering Intensity normalization Spatial
More informationTotal Variation Regularization Method for 3D Rotational Coronary Angiography
Total Variation Regularization Method for 3D Rotational Coronary Angiography Haibo Wu 1,2, Christopher Rohkohl 1,3, Joachim Hornegger 1,2 1 Pattern Recognition Lab (LME), Department of Computer Science,
More informationCT Basics Principles of Spiral CT Dose. Always Thinking Ahead.
1 CT Basics Principles of Spiral CT Dose 2 Who invented CT? 1963 - Alan Cormack developed a mathematical method of reconstructing images from x-ray projections Sir Godfrey Hounsfield worked for the Central
More informationDiagnostic quality of time-averaged ECG-gated CT data
Diagnostic quality of time-averaged ECG-gated CT data Almar Klein a, Luuk J. Oostveen b, Marcel J.W. Greuter c, Yvonne Hoogeveen b, Leo J. Schultze Kool b, Cornelis H. Slump a and W. Klaas Jan Renema b
More informationAutomatic Cerebral Aneurysm Detection in Multimodal Angiographic Images
Automatic Cerebral Aneurysm Detection in Multimodal Angiographic Images Clemens M. Hentschke, Oliver Beuing, Rosa Nickl and Klaus D. Tönnies Abstract We propose a system to automatically detect cerebral
More informationPlanmeca ProMax 3D s CBCT unit
D0010759 1(5) Planmeca ProMax 3D s CBCT unit Introduction The Planmeca ProMax 3D s X-ray unit uses cone beam computerized tomography (CBCT) to produce threedimensional X-ray images. Panoramic and cephalometric
More informationSPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing
SPM8 for Basic and Clinical Investigators Preprocessing fmri Preprocessing Slice timing correction Geometric distortion correction Head motion correction Temporal filtering Intensity normalization Spatial
More informationPlanmeca ProMax 3D Max CBCT unit
D00107623 1(6) Planmeca ProMax 3D Max CBCT unit Introduction The Planmeca ProMax 3D Max X-ray unit uses cone beam computerized tomography (CBCT) to produce threedimensional X-ray images. Panoramic and
More informationUtilizing Salient Region Features for 3D Multi-Modality Medical Image Registration
Utilizing Salient Region Features for 3D Multi-Modality Medical Image Registration Dieter Hahn 1, Gabriele Wolz 2, Yiyong Sun 3, Frank Sauer 3, Joachim Hornegger 1, Torsten Kuwert 2 and Chenyang Xu 3 1
More informationTHE DICOM 2013 INTERNATIONAL CONFERENCE & SEMINAR. DICOM Fields of Use. Klaus Neuner. Brainlab AG. Software Project Manager Feldkirchen, Germany
THE DICOM 2013 INTERNATIONAL CONFERENCE & SEMINAR March 14-16 Bangalore, India DICOM Fields of Use Klaus Neuner Brainlab AG Software Project Manager Feldkirchen, Germany Introduction This presentation
More informationFrequency split metal artifact reduction (FSMAR) in computed tomography
The Johns Hopkins University Advanced Computer Integrated Surgery Group 4 Metal Artifact Removal in C-arm Cone-Beam CT Paper Seminar Critical Review of Frequency split metal artifact reduction (FSMAR)
More informationA Spatio-temporal Denoising Approach based on Total Variation Regularization for Arterial Spin Labeling
A Spatio-temporal Denoising Approach based on Total Variation Regularization for Arterial Spin Labeling Cagdas Ulas 1,2, Stephan Kaczmarz 3, Christine Preibisch 3, Jonathan I Sperl 2, Marion I Menzel 2,
More informationAAPM Standard of Practice: CT Protocol Review Physicist
AAPM Standard of Practice: CT Protocol Review Physicist Dianna Cody, Ph.D., DABR, FAAPM U.T.M.D. Anderson Cancer Center September 11, 2014 2014 Texas Radiation Regulatory Conference Goals Understand purpose
More informationThE ultimate, INTuITIVE Mr INTErFAcE
ThE ultimate, INTuITIVE Mr INTErFAcE Empowering you to do more The revolutionary Toshiba M-power user interface takes Mr performance and flexibility to levels higher than ever before. M-power is able to
More informationBreast MRI Accreditation Program Clinical Image Quality Guide
Breast MRI Accreditation Program Clinical Image Quality Guide Introduction This document provides guidance on breast MRI clinical image quality and describes the criteria used by the ACR Breast MRI Accreditation
More informationRegistration concepts for the just-in-time artefact correction by means of virtual computed tomography
DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Registration concepts for the just-in-time artefact correction by means of virtual
More information3D Slicer Overview. Andras Lasso, PhD PerkLab, Queen s University
3D Slicer Overview Andras Lasso, PhD PerkLab, Queen s University Right tool for the job Technological prototype Research tool Clinical tool Can it be done? Jalopnik.com Innovative, not robust, usually
More informationRegistration, Matching, and Data Fusion in 2D/3D Medical Imaging: Application to DSA and MRA
Registration, Matching, and Data Fusion in 2D/3D Medical Imaging: Application to DSA and MRA Maximilien Vermandel 1, Nacim Betrouni 2, Georges Palos 2, Jean-Yves Gauvrit 1, Christian Vasseur 2, and Jean
More informationMathematical methods and simulations tools useful in medical radiation physics
Mathematical methods and simulations tools useful in medical radiation physics Michael Ljungberg, professor Department of Medical Radiation Physics Lund University SE-221 85 Lund, Sweden Major topic 1:
More informationThe team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge.
Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge Dimitre Hristov Radiation Oncology Stanford University The team Renhui Gong 1 Magdalena Bazalova-Carter 1
More informationLab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street
Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street MRI is located in the sub basement of CC wing. From Queen or Victoria, follow the baby blue arrows and ride the CC south
More informationMR-guided radiotherapy: Vision, status and research at the UMC Utrecht. Dipl. Ing. Dr. Markus Glitzner
MR-guided radiotherapy: Vision, status and research at the UMC Utrecht Dipl. Ing. Dr. Markus Glitzner About myself Training Medizintechnik TU Graz PhD UMC Utrecht Clinical work Software implementation
More informationA high accuracy multi-image registration method for tracking MRIguided
A high accuracy multi-image registration method for tracking MRIguided robots Weijian Shang* a, Gregory S. Fischer* a a Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA, USA 01609; ABSTRACT
More informationBrilliance CT Big Bore.
1 2 2 There are two methods of RCCT acquisition in widespread clinical use: cine axial and helical. In RCCT with cine axial acquisition, repeat CT images are taken each couch position while recording respiration.
More information2D-3D Rigid-Body Registration of X-Ray Fluoroscopy and CT Images by. Lilla Zöllei
2D-3D Rigid-Body Registration of X-Ray Fluoroscopy and CT Images by Lilla Zöllei Submitted to the Department of Electrical Engineering and Computer Science in partial fulfillment of the requirements for
More informationDepth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences
Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences Jian Wang 1,2, Anja Borsdorf 2, Joachim Hornegger 1,3 1 Pattern Recognition Lab, Friedrich-Alexander-Universität
More informationA Non-Linear Image Registration Scheme for Real-Time Liver Ultrasound Tracking using Normalized Gradient Fields
A Non-Linear Image Registration Scheme for Real-Time Liver Ultrasound Tracking using Normalized Gradient Fields Lars König, Till Kipshagen and Jan Rühaak Fraunhofer MEVIS Project Group Image Registration,
More informationCP467 Image Processing and Pattern Recognition
CP467 Image Processing and Pattern Recognition Instructor: Hongbing Fan Introduction About DIP & PR About this course Lecture 1: an overview of DIP DIP&PR show What is Digital Image? We use digital image
More informationRedundancy Encoding for Fast Dynamic MR Imaging using Structured Sparsity
Redundancy Encoding for Fast Dynamic MR Imaging using Structured Sparsity Vimal Singh and Ahmed H. Tewfik Electrical and Computer Engineering Dept., The University of Texas at Austin, USA Abstract. For
More informationTotal Variation Regularization Method for 3-D Rotational Coronary Angiography
Total Variation Regularization Method for 3-D Rotational Coronary Angiography Haibo Wu 1,2, Christopher Rohkohl 1,3, Joachim Hornegger 1,2 1 Pattern Recognition Lab (LME), Department of Computer Science,
More information