VueBox. Quantification Toolbox. Instructions for use. Copyright 2015 Bracco Suisse SA. Bracco Suisse SA Software Applications VBO.8.

Size: px
Start display at page:

Download "VueBox. Quantification Toolbox. Instructions for use. Copyright 2015 Bracco Suisse SA. Bracco Suisse SA Software Applications VBO.8."

Transcription

1 VueBox Quantification Toolbox Instructions for use Copyright 2015 Bracco Suisse SA Bracco Suisse SA Software Applications VBO

2 This publication may not be reproduced, stored in a retrieval system, distributed, recreated, displayed or transmitted in any form or by any means (electronic, mechanical, recording or otherwise), in whole or in part, without prior written authorization by Bracco Suisse SA. If publication of this work should occur, the following notice shall apply: Copyright 2015 Bracco Suisse SA ALL RIGHTS RESERVED. The software described in this manual is supplied under license and may only be used or copied in accordance with the terms of such license. The information in this manual is for instructional use only and is subject to change without notice. REF VueBox v6.0 Bracco Suisse SA Software Applications 2015/09 BRACCO Suisse S.A. Software Applications 31, route de la Galaise 1228 Plan-les-Ouates Genève - Suisse fax Bracco Suisse SA Software Applications VBO

3 CONTENTS 1 Introduction About this manual Interpreting symbols of the product Definitions System description Intended use Product lifetime Safety precautions Installation and maintenance Patient and user safety Measurement Installation System Requirements Installation of VueBox Activation of VueBox General review tools Interface elements Main toolbar Side toolbar Functional Reference User interface General workflow Specific application packages Principle Package selection GI-Perfusion General Imaging Perfusion Quantification Liver DVP Focal Liver Lesion Plaque Supported datasets Video settings Calibration files Clip edition Principle Interface elements Workflow Clip concatenation Flash image detection Regions of interest Principle Interface elements Workflow Dual display mode Length calibration and measurement Anonymization of clip Annotation Motion compensation Principle Workflow Perfusion data processing Principle Linearized signal Contrast arrival detection Bracco Suisse SA Software Applications VBO

4 Skip duplicate images Perfusion models Dynamic Vascular Pattern Dynamic Vascular Pattern Parametric Perfusion Segments Analysis Measurement acceptance criteria Parametric imaging Workflow Result window Interface elements Adjustable display presets Auto-scaled display presets Storing / loading display preset Parametric image overlay Perfusion instant detection Analysis result database Export analysis data Principle Interface elements Workflow Analysis report Import and export user settings About screen Quick guide General Imaging - Bolus analysis General Imaging Replenishment analysis Focal Liver Lesions, Dynamic Vascular Pattern Analysis Plaque Index Bracco Suisse SA Software Applications VBO

5 1 INTRODUCTION 1.1 ABOUT THIS MANUAL In this manual, examples, suggestions and warnings are included to help you to start using the VueBox software application and to advise you on important items. This information is indicated using the following symbols: The caution symbol indicates important information, safety precautions, or warnings. The stop symbol highlights important information. You should stop and read before continuing. The bulb symbol indicates a suggestion or an idea that simplifies the use of VueBox. It can also refer to information available in other chapters. 1.2 INTERPRETING SYMBOLS OF THE PRODUCT Symbol Location Description REF User Manual Product name and version User Manual Manufacturer s name User manual Production Year and month User Manual Conformity assessment procedure according to directive 93/42/EEC Annex II.3 Classification according to directive 93/42/EEC, Ann. IX: class IIa according to rule 10 Bracco Suisse SA Software Applications VBO

6 1.3 DEFINITIONS ASR Advanced System Recognition DVP Dynamic Vascular Pattern DVPP Dynamic Vascular Pattern Parametric FLL Focal Liver Lesion FT Fall Time MI Molecular Imaging MIP Maximum Intensity Projection mtt Mean Transit Time PA Perfused Area PE Peak Enhancement PI Perfusion Index PSA Perfusion Segments Analysis QOF Quality Of Fit rbv Regional Blood Volume ROI Region Of Interest rpa Relative Perfused Area RT Rise Time TSV Tabulation-Separated Values TTP Time To Peak WiAUC Wash-in Area Under Curve WiPI Wash-in Perfusion Index WiR Wash-in Rate WiWoAUC Wash-in and Wash-out AUC WoAUC Wash-out AUC WoR Wash-out Rate 1.4 SYSTEM DESCRIPTION VueBox is a software package useful for the quantification of blood perfusion, based on clips acquired in Dynamic Contrast Enhanced Ultrasound, in radiology applications (cardiology excluded). From the analysis of a time sequence of 2D contrast images, perfusion parameters are calculated, such as wash-in rate (WiR), peak enhancement (PE), rise time (RT) or area under curve during wash-in (WiAUC). Time parameters (e.g. RT) can be interpreted in absolute terms, and amplitude parameters (e.g. WiR, PE and WiAUC) in relative terms (vs. values in a reference region). VueBox can display the spatial distribution of any of these (and other) parameters, synthesizing time sequences of contrast images into single parametric images. Models are provided for the two most common modes of administration: bolus (wash-in / wash-out kinetics) and infusion (replenishment kinetics after destruction). For the specific case of Focal Liver Lesions (FLL), the Dynamic Vascular Pattern (DVP) of a lesion in comparison with its surrounding healthy parenchyma is displayed. Moreover, the DVP information over time is summarized in a single parametric image defined as Dynamic Vascular Pattern Parameter (DVPP). For the quantification of atherosclerotic plaques, as a way to identify vulnerable plaques, specific tools are necessary. These tools include a multi-scale graph, specific perfusion quantification methods, and specific quantification parameters such as Perfused Area (PA), relative Perfused Area (rpa). 1.5 INTENDED USE VueBox is intended to assess relative perfusion parameters in radiology applications (cardiology excluded), based on 2D DICOM datasets acquired in Dynamic Contrast Enhanced Ultrasound examinations. Bracco Suisse SA Software Applications VBO

7 The visualization of DVP through a contrast ultrasound examination after a bolus administration shall help clinicians characterize suspicious lesions, and better differentiate benign from malignant lesion types. The plaque package assesses pathologies of carotid arteries during a contrast ultrasound examination after a bolus administration. 1.6 PRODUCT LIFETIME For a given version of the product, the software and its documentation are supported for five years after the release date. 1.7 SAFETY PRECAUTIONS Please read the information in this section carefully before using the program. This section contains important information on safe operation and handling of the program as well as information on service and support. Only trained and licensed medical practitioners are authorized to use the system. Any diagnosis based on the usage of this product must be confirmed by a differential diagnosis prior any treatment according to common medical sense. Only 2D DICOM datasets of Dynamic Contrast Enhanced Ultrasound examinations for which a calibration file is available should be processed. 1.8 INSTALLATION AND MAINTENANCE Bracco Suisse SA assumes no liability for problems attributable to unauthorized modifications, additions or deletions to Bracco Suisse SA software or hardware, or unauthorized installation of third party software. As manufacturer and distributor of this product, Bracco Suisse SA is not responsible for safety, reliability and performance of the system, if: the product is not operated in accordance with the operating manual the product is operated outside of its operating conditions the product is operated outside of the specified operating environment. 1.9 PATIENT AND USER SAFETY The user must be satisfied with the suitability and completeness of clips acquired in a study, prior to analysis with VueBox. If not, acquisitions have to be repeated. For information about performing contrast acquisitions for reliable perfusion quantification, please refer to the operating instructions provided by the manufacturer of your ultrasound equipment as well as to Bracco s Application note Protocol for performing reliable perfusion quantification. The information contained in this manual is intended only for the operation of Bracco Suisse SA application software. It does not include information on echocardiograms or general ultrasound acquisition. Please refer to the operating instructions of your ultrasound equipment for further information. Bracco Suisse SA Software Applications VBO

8 1.10 MEASUREMENT The user is responsible for a suitable choice of ROI (Region of interest), in order to include contrast-ultrasound data only. ROI should not include any overlays such as texts, labels or measurements and should be drawn on ultrasound data acquired with a contrast-specific mode only (i.e. no Fundamental B-Mode or Color Doppler overlays). The user is responsible for determining if artifacts are present in the data to be analyzed. Artifacts can severely affect the analysis outcome and require a reacquisition. Examples of artifacts are: obvious discontinuity due to a jerky motion during acquisition or because the acquisition plane changed; excess shadowing in images; poorly defined anatomy or evidence of distorted anatomical representation. In the case of a poorly reconstructed image, as determined by the above criteria (e.g. artifacts) or by the user's clinical experience and training, measurements should not be made and must not be used for any diagnostic purposes. The user must ensure the accuracy of the images and measurement results. Acquisitions should be repeated if there is the slightest doubt as to the accuracy of images and measurements. The user is responsible for a suitable length calibration. In case of incorrect usage, wrong measurement results may occur. The user should always make sure to select the appropriate calibration according to the ultrasound system, probe and settings used. This control should be performed for each clip to be analyzed. Bracco Suisse SA Software Applications VBO

9 2 INSTALLATION 2.1 SYSTEM REQUIREMENTS Minimum Proposed CPU Intel Pentium Intel Core 2 Duo E8400 or better RAM 1 GB 2 GB or more Graphics Card Nvidia GeForce 8500GT 512DDR Minimum Resolution 1024x768 Nvidia GeForce 8800GT 1024DDR Resolution 1280x1024 and higher Monitor 17 SVGA (CRT) 19 TFT Flat Screen or higher Additional Requirements Operating System: Screen text size Microsoft Windows VISTA (SP1), 32 bit / 64 bit Microsoft Windows 7, 32 bit / 64 bit Microsoft Windows 8, 32 bit / 64 bit Microsoft Windows 10, 32 bit / 64 bit 96 dpi Please make sure that your screen resolution fulfills the minimum requirement and that your DPI (Dots Per Inch) setting is set at INSTALLATION OF VUEBOX The installation package of VueBox includes the following mandatory prerequisites: Microsoft.NET Framework SAP Crystal Report Runtime Engine for.net Framework 4.0 Visual C Runtime Libraries Visual C Runtime Libraries During the installation procedure, you will be automatically prompted if any of these prerequisites needs to be installed. Please perform the following steps in order to install VueBox : 1. close all applications, 2. run the setup.exe installation package located in VueBox installation folder, 3. accept the installation of the prerequisites (if not already installed), 4. select the installation folder and press Next, 5. follow the on-screen instructions, 6. at the end of the installation, press Close. The installation is now complete. VueBox can be started from the VueBox folder in the start menu or more directly using the desktop shortcut. VueBox can be uninstalled through the Add / Remove software feature from the Windows control panel. Bracco Suisse SA Software Applications VBO

10 2.3 ACTIVATION OF VUEBOX At first start-up, VueBox launches an activation process that will validate and unlock the copy of the software application. In this process you will be prompted to enter the following information: Serial number address Hospital / Company name. The activation needs to communicate these information to the activation server. This can be performed automatically through the online activation, or manually using the e- mail activation. In the online activation, VueBox will be activated and unlocked automatically, by simply following the on-screen instructions. In the activation, an including all necessary information for the activation of VueBox will be generated and you will be asked to send it to the activation server ( address will be displayed). Within a few minutes, you will receive an automatic reply by including an unlock code. This unlock code will be required at the next start-up of VueBox to finalize the activation process. Please note that this activation process, either through the online or the method, needs to be performed only once. Bracco Suisse SA Software Applications VBO

11 3 GENERAL REVIEW TOOLS 3.1 INTERFACE ELEMENTS MAIN TOOLBAR Available in mode Item Function Clip editor Motion comp. Result Comments 1 Clip editor X X Return to the clip editor mode. 2 Length Calibration X X X Set a known distance in the image to calibrate for length and area measurements. (Not available in the segmentation packages) 3 Copy ROI X X X Copy all ROI of the current active window into the ROI database. 4 Paste ROI X X X Paste selected ROI set from the ROI database. 5 Motion compensation 6 Perfusion data processing X X Apply spatial realignments on all images using a specific reference image. (Not available in the segmentation packages) X X Perform perfusion quantification or calculate DVP according to selected package 7 Save result X Store a result file (analysis result context) into the result database. (Not available in the segmentation packages) 8 Validate segmentation X Save the segmentation results (Only available in the segmentation packages) 9 Export data X Export selected data (e.g. quantification data, screenshots, movies). (Not available in the segmentation packages) 10 About X X X Display the about screen. Bracco Suisse SA Software Applications VBO

12 11 Exit X X X Close all clips opened and exit the software SIDE TOOLBAR Available in mode Item Function Clip editor Motion comp. Result Comments 11 Import / Export user settings 12 Length Measurement X X X Import / export user settings (i.e. ROI, result and display preset databases). X X X Measure distances in the image. 13 Annotations X X X Add text labels on images. 14 Anonymize X X X Hide patient s name and identification. Bracco Suisse SA Software Applications VBO

13 4 FUNCTIONAL REFERENCE To get instant help on working with VueBox, click the toolbar and click the help button. button in the main You will need Adobe Acrobat Reader to display the software manual. If Adobe Acrobat Reader is not installed on your system, please download the latest version from USER INTERFACE VueBox is a multiple window interface software application. The possibility to process several clips in separate child windows comes in handy for the user who, for example, wants to analyze different cross-sections of a given lesion at the same time. Another example is the case of a user who is interested to compare a given lesion imaged at different dates. Each analysis is performed in an individual, independent child window. VueBox is also multitasking, as each child window can execute processing at the same time while keeping the parent interface responsive. Furthermore, calculations that are demanding in terms of computing power, such as computing the perfusion quantification, have been optimized to benefit from multicore processors when available, a technology called parallelization. When VueBox is launched, a start page is shown indicating the software name and version number. From this start page, packages (e.g. GI-Perfusion, Liver DVP, Plaque), containing a set of dedicated features to be used in a specific context, can be selected. Figure 1 VueBox start page When VueBox is launched from TomTec s Image-Arena platform, the start page cannot be accessed. The data selection must be performed from Image- Arena. Bracco Suisse SA Software Applications VBO

14 Once a package is selected, clips can be opened; recent clips and recent analyses, if applicable, can be quickly reopened. Moreover, when a recent clip is selected, its associated analyses (i.e. previously saved analysis contexts) are accessible and can be restored. Once a clip is opened, a one-quadrant view is displayed, including the video settings toolbar, the clip editor as well as the remaining functionalities useful prior to launching the analysis process (e.g. ROI drawing toolbar, etc.). Patient ID Main toolbar ROI toolbar Side toolbar Video settings Clip Editor Figure 2 - One-quadrant view Finally, when the perfusion data processing is completed, results are presented in a fourquadrant view, where time-intensity curves, parametric images, time intensity curves and perfusion parameter values are displayed. Bracco Suisse SA Software Applications VBO

15 Display settings Parametric image Time- Intensity curves Perfusion parameter selection Parameter table Figure 3 - Four-quadrant view 4.2 GENERAL WORKFLOW The application workflow is easy and intuitive for a routine clinical use. It consists of the following steps: 1. Choose an application package 2. Load a dataset 3. Adjust video settings 4. Select perfusion model, if applicable 5. Remove unwanted images with the clip editor 6. Draw several ROI 7. Apply motion compensation if needed 8. Perform quantification 9. Visualize, save and export results 4.3 SPECIFIC APPLICATION PACKAGES PRINCIPLE While VueBox is a general quantification toolbox, dedicated features have been developed to address specific needs (e.g. DVP for focal liver lesions, see section 4.3.4). These dedicated features are placed into packages, which can be selected according to user needs. In most cases, the core features of VueBox (e.g. video data linearization, clip edition, ROI drawing, motion compensation, analysis context saving, result exporting, etc.) are similar in all packages PACKAGE SELECTION Specific application packages can be selected in the start page (see section 4.1) by clicking on the appropriate button. Bracco Suisse SA Software Applications VBO

16 Figure 4 - Specific application package selection The user should make sure to select the appropriate package in order to perform its analysis (e.g. Liver DVP for focal liver lesions) GI-PERFUSION GENERAL IMAGING PERFUSION QUANTIFICATION The General Imaging Perfusion Quantification package contains generic perfusion quantification tools, including both Bolus and Replenishment perfusion models (see section ), allowing to extract quantitative perfusion estimates through perfusion parameters in general radiology applications (cardiology excluded) LIVER DVP FOCAL LIVER LESION The Focal Liver Lesion-dedicated package contains the following specific tools for the analysis of FLLs: Liver-dedicated Bolus perfusion model (i.e. Bolus Liver) Dynamic Vascular Pattern (see section ) Dynamic Vascular Pattern Parametric (see section ) Customized analysis report (see section ) These tools allow the enhancement of blood perfusion differences between liver lesions and parenchyma. This package does not include any perfusion quantification tools, as opposed to the General Imaging Perfusion Quantification Package PLAQUE The plaque package contains tools dedicated to the quantification of atherosclerotic plaques. To identify vulnerable plaques, specific tools are available such as: Perfused Area (see section ) Relative Perfused Area (rpa) Mean MIP Opacification (MIP) Mean MIP Opacification Perfused Pixel only (MIP th) 4.4 SUPPORTED DATASETS VueBox supports contrast ultrasound 2D DICOM clips of systems for which linearization tables are available (also called calibration files). Other datasets such as Color Doppler clips, B-mode clips and contrast/b-mode overlay displays are not supported. Bracco Suisse SA Software Applications VBO

17 For ASR-compatible (Advanced System Recognition) ultrasound systems, linearization is performed automatically and manual selection of a calibration file is not required. More information can be found on In general, bolus clips longer than 90 seconds are recommended so as to include wash-in and wash-out phases. Replenishment clips can be substantially shorter. 4.5 VIDEO SETTINGS The video settings panel is shown when a clip is loaded in the software. In this panel, you need to: define the desired sub-sampling rate if needed, so as to reduce the number of frames to be processed (optional), select the appropriate ultrasound system and settings used for the acquisition so as to apply the correct linearization function to the image data (mandatory), Figure 5 - Video settings panel activate the dual display mode if the clip was recorded with both contrast and fundamental B-mode images side-by-side (or above each-other) on screen (optional), select the gain compensation so as to compensate for gain variations across different exams in order to be able to compare results of a given patient at different visits (optional). Bracco recommends activating the dual display mode when available, as this feature increases the robustness of the motion compensation algorithm. Default values are kept in memory from one session to another (e.g. last ultrasound system used, etc.). Therefore, it is important to make sure that these settings are correct before continuing with the analysis. The user should make sure that the clip frame rate read from the DICOM file and displayed in the video settings panel is correct before pursuing the analysis. An incorrect frame rate may result in a wrong time base and, thus, affect the computed values of perfusion parameters. 4.6 CALIBRATION FILES Calibration files contain the appropriate linearization function and color map correction for a given ultrasound system and specific setting (i.e. probe, dynamic range, color map, etc.). Using calibration files, the VueBox can convert video data extracted from DICOM clips into echo-power data, a quantity directly proportional to the instantaneous concentration of contrast agent concentration at each location in the field of view. Bracco Suisse SA Software Applications VBO

18 Calibration files are distributed to users according to their ultrasound system(s) (e.g. Philips, Siemens, Toshiba, etc.) and can be added to VueBox by a simple drag & drop into the VueBox user interface. The most common settings are available for each ultrasound system. However, new calibration files can be generated, with specific settings, upon users' request. Please contact your local Bracco representative for more information on how to obtain additional calibration files. 4.7 CLIP EDITION PRINCIPLE The clip editor module allows you to limit the analysis to a specified time window, and also to exclude unwanted images from processing (either isolated or in ranges). As illustrated on the figure below, the clip editor may be used to retain, within the washin and wash-out phases of a bolus, only the images within a relevant time interval. If the destruction-replenishment technique is applied during the experiment, the clip editor automatically defines selectable replenishment segments by including images between two destruction events only. (a) BOLUS Relevant time interval (b) REPLENISHMENT Replenishment segments: 1 st 2 nd Destruction event Time Time Image status bar: Exclusion Inclusion Image status bar: Exclusion Inclusion (selected segment) Destruction Figure 6 - Typical examples of clip edition Using the bolus perfusion model, the user should make sure to include both wash-in and wash-out phases. Not doing so may affect the outcome of the perfusion data processing. For the specific case of the Molecular Imaging package, the number of frames used for analysis should never be lower than INTERFACE ELEMENTS Figure 7 shows a screenshot of the interface elements in the clip editor in the replenishment mode. Bracco Suisse SA Software Applications VBO

19 Figure 7 User interface in the clip editor in the replenishment mode. Element Name Function Image display Image number Time indicator Zoom In / Out Image slider Image status bar Play shows the order number of the currently displayed image as well as the total number of images available in the clip. shows the time instant of the currently displayed image. increases or decreases the image size. selects the image to be displayed. If the cursor points to an excluded image, a red frame appears around it. shows excluded and included image ranges in red and green, respectively. Destruction images are shown in orange. runs the movie player. Fast play runs the movie player in fast mode. Bracco Suisse SA Software Applications VBO

20 Clip editor Exclude Include Add Flash Replenishment segment selector sets the exclusion mode. sets the inclusion mode. marks the current image as flash (see section 4.7.5). selects the previous/next replenishment segment (only available if the clip includes destruction-replenishment segments) WORKFLOW EXCLUDING IMAGES To exclude a range of images: 1. Move the Image slider to the first image to be excluded 2. Click the Exclude button 3. Move the Image slider to the last image to be excluded. INCLUDING IMAGES To include a range of images: 1. Move the Image slider to the first image to be included 2. Click the Include button 3. Move the Image slider to the last image to be included CHANGING THE RANGE OF EXCLUDED IMAGES To change the range of excluded images: 1. Move the mouse pointer over the Image status bar to any border of a range of excluded images ( ) 2. When the pointer's shape changes to a vertical split, drag the border to change the range of excluded images. MOVING THE RANGE OF EXCLUDED IMAGES To move the range of excluded images: 1. Move the mouse pointer over the Image status bar to any border of a range of excluded images ( ) 2. When the pointer's shape changes to a vertical split, press the Shift key and drag the range of excluded images to the desired position CLIP CONCATENATION The clip concatenation, or combination, is the process of pooling clips together to build up a single sequence of images. Using this feature, a set of clips recorded in chronological order by an ultrasound scanner can be processed. The concatenation function is useful when the ultrasound system has a limited clip recording time per DICOM file. Bracco Suisse SA Software Applications VBO

21 Bracco recommends concatenating clips with a clip-transition delay 15 seconds. Concatenate clip Move up selected clip Delete selected clip Move down selected clip opens and concatenates a clip with the current clip. moves up the selected clip in the Clip selector list. removes the selected clip from the Clip selector list. moves down the selected clip in the Clip selector list. Transition delay sets the transition delay (in seconds) between the beginning of the selected clip and the end of the previous one to account for this delay in the analysis. Clip selector selects a clip in the list FLASH IMAGE DETECTION The selection of the perfusion model (i.e. Bolus or replenishment) can be performed in the clip editor. So as to reduce the risk of selecting a wrong model (e.g. the replenishment model for a bolus injection), the replenishment button becomes active only if the software has detected flash images in the clip. The flash detection is an automatic process launched every time a clip is loaded in VueBox. Figure 8 - Flash image detection The automatic flash image detection progress can be seen in the clip editor toolbar as shown in the figure above. In some cases, this detection may not be accurate. Therefore, you may want to cancel it when the automatic detection is not accurate or fails. To cancel this flash image detection or to remove unwanted flash images: 1. if the detection is still being performed, click on the "X" button to stop it. 2. If the detection is completed, click on the destruction orange square located in the clip editor caption (with a X letter inserted). However, the "Replenishment" model will not be accessible anymore. Therefore, if you want to process destruction / replenishment clips with the replenishment model, you will Bracco Suisse SA Software Applications VBO

22 need to identify flash images manually by placing the image slider at the desired location and clicking the button or pressing the "F" keyboard key on each destruction frame. Flash image detection and/or manual definition is not available in all packages (e.g. Liver DVP and Plaque, which are compatible for bolus kinetics only). 4.8 REGIONS OF INTEREST PRINCIPLE With the help of the ROI toolbar, you can define up to five Regions of Interest on images of the clip using the mouse; a mandatory ROI named Delimitation and up to four generic ROI. The Delimitation ROI is used to delimit the processing area. It must thus exclude any non-echographic data, such as text, colorbars or image borders. A first generic ROI (e.g. ROI 1) usually includes lesion if applicable and a second generic ROI (e.g. ROI 2) may include healthy tissue to serve as reference for relative measurements. Note that ROI names are arbitrary and can be entered by the user. An additional two ROI are available to user s discretion. Figure 9 - Example of Regions of interest For the specific case of the Liver DVP package (see section 4.3.4), ROI are not generic anymore and have a specific use. Beside the Delimitation ROI, the following 4 ROI are available: Lesion 1, Reference, Lesion 2, Lesion 3. Note that Lesion 1 and Reference ROI are mandatory. For the specific application package Plaque, ROI are not generic anymore and have a specific use. Beside the Delimitation ROI, the following 4 ROI are available: Plaque 1, Lumen, Plaque 2, Plaque 3. Note that Plaque 1 and Lumen ROI are mandatory. The plaque ROI(s) must delineate all the plaque(s), whereas the Lumen ROI must contain a part of the lumen (cf. Figure 23 for an example) INTERFACE ELEMENTS The ROI toolbar (located in the upper-left corner of the image viewer) offers tools to draw four different shapes. The ROI label on the right of the toolbar identifies the current region to be drawn, and may be edited by clicking on it. Figure 10 ROI toolbar Button Name Function Select allows to select / modify a region of interest. Rectangle draws a rectangular shape. Bracco Suisse SA Software Applications VBO

23 Ellipse draws an elliptical shape. Polygon draws a closed polygonal shape. Closed curve draws a closed curvilinear shape WORKFLOW DRAWING A ROI To draw a rectangular or elliptical ROI: 1. Select a shape in the ROI toolbar ( or ) 2. Move the mouse pointer to the wanted location in the B-mode image (left side) or the contrast image (right side) 3. Click and drag to draw the ROI. To draw a closed polygonal or curved ROI, 1. Select a shape in the ROI toolbar ( or ) 2. Move the mouse pointer to the wanted location in the B-mode image (left side) or the contrast image (right side) 3. To add anchor points, click repeatedly while moving the mouse pointer 4. Double-click at any time to close the shape. DELETING A ROI To delete a ROI: 1. Right click in the image to set the ROI selection mode or click the button 2. Move the mouse pointer to any border of the ROI 3. Select the ROI using the left or right mouse button 4. Press either the DELETE or BACKSPACE keys. MOVING A ROI To change the location of a ROI: 1. Right click in the image to set the ROI selection mode or click the button 2. Move the mouse pointer to any border of the ROI 3. When the pointer shape changes to a double-arrow, click and drag the ROI to a new location EDITING A ROI To change the location of anchor points of a ROI: 1. Right click in the image to set the ROI selection mode or click the button 2. Move the mouse pointer to any anchor point of the ROI 3. When the pointer shape changes to a cross, click and drag the anchor point to a new location. Bracco Suisse SA Software Applications VBO

24 COPYING AND PASTING ROI Regions of interest can be copied into a ROI library and pasted at a later time point, in any clip analysis. To copy all the ROI currently drawn: 1. Click the button in the main toolbar 2. Set a name or accept the default generated one and press the OK button Figure 11 - Copying ROI into library To paste ROI from the library: 1. Click the button in the main toolbar 2. Select the item in the list and press the OK button Figure 12 - Pasting ROI from library DUAL DISPLAY MODE The dual mode is active when a clip is split into two image areas: contrast and fundamental B-mode. Each image area may be identified by its orientation marker, usually the logo of the ultrasound scanner manufacture, showing the scan orientation of the probe. Figure 13 - Dual display mode with automatic or manual detection options In this mode, ROI can be drawn on any side (i.e. contrast or B-mode) provided that that the contrast side is manually determined by the user. This operation is performed by first enabling the dual display mode in the video settings panel and then by left-clicking on the orientation marker of the contrast image. VueBox delineates the orientation marker using a white rectangle and detects the corresponding marker on the B-mode side automatically. Bracco Suisse SA Software Applications VBO

25 Time 1 st Figure 14 - Orientation marker detection in dual display mode In some cases, similar orientation markers on both contrast and B-mode images may not be available. Thus, the automatic detection cannot be performed and the manual selection of landmarks within both images should be chosen. To activate dual display with automatic detection (i.e. both probe orientation markers are available): 1. Set the toggle button to On in the dual display section of the video settings panel 2. Make sure that the toggle button is set to Auto 3. Click on the probe orientation marker of the contrast image 4. Control that the corresponding orientation marker located on the B-mode image is correctly detected To activate dual display with manual landmarks selection (i.e. no or different probe orientation markers present): 1. Set the toggle button to On in the dual display section of the video settings panel 2. Set the toggle button to Manual 3. Click on an image landmark of the contrast image 4. Click on a corresponding image landmark of the B-mode image 5. Note: By pressing the left mouse-button in the vicinity of each landmark, a magnifying tool is activated to help the user position a cursor in a very precise way The user should make sure to select the correct orientation marker (i.e. on the contrast-image side). Otherwise, all ROI may be inverted and all analysis results will be invalid. In the manual landmarks selection mode, the user should carefully select a pair of image landmarks spaced in exactly the same way as the B-mode and contrast images. Otherwise, ROI positioning may be incorrect and this may degrade both image registration and analysis results. When processing an ASR-compatible DICOM clip, the dual display mode is automatically enabled if the clip contains both contrast and fundamental B- mode image areas. Bracco Suisse SA Software Applications VBO

26 4.9 LENGTH CALIBRATION AND MEASUREMENT The Length Calibration tool is required for performing length and area measurements of anatomical objects in the images. It consists in identifying a known distance in any image of the clip. Once the line is drawn, the effective corresponding distance in mm needs to be entered. To calibrate: 1. click the length calibration button, 2. draw a line on a known distance in the image (e.g. along a calibrated depth scale), 3. in the Length calibration dialog box, type the known corresponding distance in mm. Once the Length calibration has been defined, areas of regions of interest will be listed in cm 2, in the quantitative parameter table. The lengths within the images can be measured with the Length measurement tool. The first Measurement tool is called ruler and is used for drawing straight lines. The second one is called cross ruler and is able to draw a cross, 2 lines perpendicular to each other. To make a length measurement: 1. click the length measurement button, 2. select the type of ruler in the ROI toolbar (line or cross), 3. draw the ruler on the image by holding down the left mouse button and drag the line to change its length. The ruler direction, location and size can be modified with the same procedure, 4. the cross ruler follows the same principle. The user must know that the perpendicular line may be shifted by moving the mouse in the direction opposite to the first line. The accuracy of the measurement tools was verified and the following error should be taken into account: Error on Length (horizontal and vertical) < 1% Error on Area < 1% Bracco Suisse SA Software Applications VBO

27 4.10 ANONYMIZATION OF CLIP The Anonymize Clip Tool is useful for presentations, lectures or any occasions in which the patient information must be removed to comply with privacy protection. This tool is available at any processing stage of VueBox. The user can move or resize the anonymization mask to hide the patient name. This mask is automatically filled with the most prominent color from the portion of the image covered. The general workflow is as follows: 1. Click the Anonymize button. 2. Adjust and move the Anonymize mask (rectangular shape) to where the information to be hidden is located in the image. Figure 15 - Anonymization mask 4.11 ANNOTATION The Annotation Tool is used for labeling important parts of the image (for instance, the lesion type). After selecting the tool, click at a desired location for the annotation in the image. Then, the software displays a dialog box in which you may enter text. Annotations can be moved or deleted exactly like ROIs, using either the DELETE or BACKSPACE key MOTION COMPENSATION PRINCIPLE Motion compensation is a key tool for allowing reliable perfusion assessments. Motion in a clip can be due to internal organ movements, such as breathing, or to slight probe movements. Manual alignment of individual images is extremely time-consuming and thus not proposed in VueBox. VueBox provides an automatic motion correction tool to correct in-plane breathing-motion and probe movements by spatially realigning anatomical structures with respect to a user-selected reference image. Lateral Motion (breathing) Automatically Compensated Motion Time Figure 16 - Motion compensation example WORKFLOW To apply motion compensation: 1. Move the Image slider to choose a reference image 2. Click the button in the main toolbar Bracco Suisse SA Software Applications VBO

28 3. Once motion compensation is applied, the native clip editor is replaced by a motion-corrected clip editor, where the clip resulting from the motion compensation process can be further edited. At this stage, colors of the Image status bar ( ) representing excluded and included image ranges are set to violet and blue, respectively. 4. Check the accuracy of the motion compensation by scrolling through the clip using the Image slider (motion compensation is considered a success if the images are spatially realigned and any residual motion is deemed acceptable) 5. If the motion compensation is unsuccessful, try one of the following: 6. Use the scissors and select another reference image and click the button again to re-apply Motion compensation. 7. Use the Clip editor to exclude any images thought to be degrading the result of motion compensation, such as out-of-plane movements, and then reapply Motion compensation. The user is responsible for checking the accuracy of the motion compensation before pursuing the clip analysis. In case of failure, incorrect results may occur. The user should exclude any out-of-plane images using the clip editor before performing a motion compensation. The user should avoid performing motion compensation when the clip does not contain any motion as this may degrade slightly the analysis results PERFUSION DATA PROCESSING PRINCIPLE The Perfusion data processing (or perfusion quantification) feature represents the core of the VueBox functionality and performs quantification in two steps. Video data are first converted into echo-power data, a quantity directly proportional to the instantaneous concentration of contrast agent concentration at each location in the field of view. This conversion process, called linearization, takes into account color or greyscale rendering, the dynamic range of log-compression used during the clip acquisition and compensates for contrast gain, as long as pixel intensity is not truncated or saturated. The echo-power data as a function of time, or Linearized signals, are then processed to assess blood perfusion, using a curve-fitting approach with a parametric Perfusion model. The parameters derived from such a model are called Perfusion parameters and are useful for relative estimates of local perfusion (e.g. in terms of relative blood volume or relative blood flow). For instance, theses parameters may be particularly useful for assessing the efficacy of given therapeutic agents at different times. In the next sections, the concepts of linearized signal, perfusion modeling and parametric imaging are explained further LINEARIZED SIGNAL A linearized (or echo-power) signal represents echo-power data as a function of time at either the pixel level or in a region of interest. The linearized signal results from a linearization process of the video data and is proportional to the local ultrasound agent concentration. As it is expressed in arbitrary units, only relative measurements are possible. For instance, let s consider echo-power amplitudes at a given instant in two ROI, one in a tumor and one in surrounding parenchyma. If the echo-power amplitude is twice as high in the tumor than in the parenchyma, this means that the concentration of ultrasound contrast agent in the lesion is close to double that present in the parenchyma. The same is true at the pixel level. Bracco Suisse SA Software Applications VBO

29 CONTRAST ARRIVAL DETECTION At the beginning of the perfusion quantification process, when the Bolus model is selected, the arrival of contrast is detected within the ROIs. The time of contrast arrival is automatically determined as the instant when the echo-power amplitude rises above the background (wash-in phase), and is represented by a red line. As shown in the Contrast arrival detection dialog box, this instant remains a suggestion which may be modified by dragging the red cursor line. After pressing the OK button, all images preceding the selected instant will be excluded from the analysis and the clip time origin will be updated accordingly. This instant should be shortly before contrast arrival in any region. Figure 17 - Contrast arrival detection dialog box The automatic contrast arrival detection is to be considered as a suggestion only. The user should make sure to review this suggestion before pressing OK SKIP DUPLICATE IMAGES Duplicate images (i.e. two or more consecutive similar images) may be found when a clip was exported from the ultrasound scanner at a frame rate higher than the acquisition frame rate (e.g. 25 Hz instead of 8 or 15 Hz). In this case, duplicate images are found in the clip. In order to insure a correct analysis as well as reliable time-related parameters, the duplicate images have to be discarded. To do so, when the clip is being loaded in memory, the software compares each frame with the previous one and discards any duplicate ones. This operation is automatic and requires no user intervention PERFUSION MODELS Perfusion estimates in VueBox are made by a curve fitting process that adjusts the parameters of a mathematical model function to fit the experimental linearized signal in an optimal way. In the context of ultrasound contrast imaging, the mathematical function is called Perfusion model and is chosen to represent either bolus kinetics or replenishment kinetics following bubble destruction. Such models serve to estimate sets of Perfusion parameters for quantification purposes. These parameters can be divided into three categories: those representing an amplitude, a time and a combination of amplitude and time. Firstly, amplitude related parameters are expressed as echo-power, in a relative way (arbitrary units). Typical amplitude parameters are the peak enhancement in a bolus kinetics, or the plateau value in a replenishment kinetics, which may be associated with relative blood volume. Secondly, time related parameters are expressed in seconds and refer to the timing of the contrast-uptake kinetics. As an example of time parameter in a bolus, the rise time (RT) measures the time that a contrast echo signal takes to go from baseline level to peak enhancement, a quantity Bracco Suisse SA Software Applications VBO

30 related to bloodflow velocity in a portion of tissue. Finally, amplitude and time parameters may be combined so as to produce quantities related to the blood flow (= blood volume / mean transit time) for replenishment kinetics or the wash-in rate (= peak enhancement / rise time) for bolus kinetics For Bolus kinetics, VueBox provides the following parameters, illustrated in the figure hereafter: PE Peak Enhancement [a.u] WiAUC Wash-in Area Under the Curve ( AUC (TI:TTP) ) [a.u] RT Rise Time ( TTP TI ) [s] mttl mean Transit Time local ( mtt TI ) [s] TTP Time To Peak [s] WiR Wash-in Rate ( maximum slope ) [a.u] WiPI Wash-in Perfusion Index ( WiAUC / RT ) [a.u] WoAUC Wash-out AUC ( AUC (TTP:TO) ) [a.u] WiWoAUC Wash-in and Wash-out AUC ( WiAUC + WoAUC ) [a.u] FT Fall Time ( TO TTP ) [s] WoR Wash-out Rate ( minimum slope ) [a.u] QOF Quality Of Fit between the echo-power signal and f(t) [%] Where TI is the instant at which the maximum slope tangent intersects the x-axis (or offset value if present), and TO is the instant at which the minimum slope tangent intersects the x-axis (or offset value if present). For Replenishment kinetics, VueBox provides the following parameters, illustrated in the figure hereafter: Bracco Suisse SA Software Applications VBO

31 rbv relative Blood Volume ( A ) [a.u] WiR Wash-in Rate ( maximum slope ) [a.u] mtt mean Transit Time [s] PI Perfusion Index ( rbv / mtt ) [a.u] QOF Quality Of Fit between the echo-power signal and f(t) [%] where [a.u] and [s] are arbitrary unit and second, respectively. The selection of the perfusion model (e.g. Bolus, Replenishment) can be performed in the Perfusion Models tab. Figure 18 - Perfusion model selection Note: the availability of perfusion models depends on the selected application package (see section 4.3). The user must ensure that the right perfusion model was selected before performing the perfusion data processing otherwise analysis results may be incorrect. The user must ensure that perfusion kinetics are not affected by any vessel or artifact. Bracco Suisse SA Software Applications VBO

32 Echo power [a.u.] In the replenishment perfusion case, the user must ensure that the plateau value is reached before considering analysis results DYNAMIC VASCULAR PATTERN This feature is available in the Liver DVP application package (see section 4.3.4). For the specific case of Focal Liver Lesions (FLL), the Dynamic Vascular Pattern (DVP) can be used to highlight how the contrast agent is being distributed in the lesion compared with the healthy liver tissue. Therefore the hyper-enhanced and hypo-enhanced pixels are being displayed over the time. Hyper-enhanced areas are displayed using warm colors, whereas hypo-enhanced ones are represented with cold hues. DVP signal is defined as the subtraction of a reference signal from pixel signals: f DVP (x, y, t) = [f(x, y, t) O(x, y)] [f REF (t) O REF ] Where f is the instantaneous signal and O the offset associated with (x,y) pixel coordinates. On the basis of this result the software will display a curve representing the distribution of the contrast agent. 15 (a) Healthy parenchyma (REFERENCE) Lesion 1 Lesion 2 10 (b) Healthy parenchyma - REFERENCE Lesion 1 - REFERENCE Lesion 2 - REFERENCE (c) Time [s] Time [s] Figure 19 - DVP processing In the above figure, (a) represents a simulation of the perfusion kinetics of healthy parenchyma taken as the reference (black), of a fast-washing lesion 1 (red) and of a slow-washing lesion 2 (green), (b) is the DVP processed signals expressed as differences of echo-power signals with respect to the reference, and (c), the bipolar color map, coding in warm and cold colors the positive and negative amplitudes, respectively, resulting from subtraction DYNAMIC VASCULAR PATTERN PARAMETRIC This feature is available in the Liver DVP application package (see section 4.3.4). In addition to the DVP feature (see section ), the Dynamic Vascular Pattern Parametric (DVPP) maps difference signals signatures into a single image, called DVP parametric image. Bracco Suisse SA Software Applications VBO

33 Using DVP signals, a classification is performed at the pixel level where each pixel is categorized into four classes according to the polarity of its difference signal over time, namely unipolar positive + (hyper-enhanced signature), unipolar negative - (hypo-enhanced signature), bipolar positive +/- (a hyper-enhancement followed by a hypoenhancement) and, conversely, bipolar negative -/+. A DVP parametric image is then built as a color-coded map, where pixels with red-, blue-, green-, and yellow-hue colors correspond to +, -, +/- and -/+ classes, respectively, with a luminance proportional to the difference signal energy. Figure 20 - Example of DVPP images PERFUSION SEGMENTS ANALYSIS This feature is available in the Plaque application package (see section 4.3.5). For the plaque application package, a reference ROI must be defined in the lumen, further to the plaque ROI(s). Also, for this specific package, no curve fitting is applied on linearized data. However, a Maximum Intensity Projection is performed on a small portion of the linearized data. Indeed, only 3 time segments (1 baseline segment and 2 perfusion segments) will be analyzed. As shown in Figure 21, the baseline segment is a 1 second interval selected before the contrast arrival time in the lumen. And the perfusion segment is the concatenation of 2 segments of 2 seconds interval (the first one starts 2 seconds after the peak in the lumen, and the second one 7 seconds after the peak). Bracco Suisse SA Software Applications VBO

34 Then, the MIP processing (for each individual pixel in the plaque ROI) is performed in two steps: A noise level detection, based on the last MIP image in the baseline time segment. The filtering of pixels, based on the last MIP image in the perfused segment, and on the threshold defined after the noise level. Echo-power Baseline Perfusions 1s 2s 2s 3s 2s Lumen Plaque Contrast arrival time (Lumen) Time to Peak (Lumen) Time Figure 21 - Baseline and Perfused segments detection The time segments (baseline and perfusions) are automatically detected by VueBox, and displayed in the Frame segments detection dialog box (cf. Figure 22). The signal of each ROI is displayed in a multi-scale time/intensity graph. The left scale (in white) is dedicated to the plaque ROI(s), whereas the right one (yellow) is the scale associated to the lumen ROI. In this graph, the user can modified the location of each time segment independently, by a drag and drop operation. Figure 22 - Frame segments detection dialog box Finally the following parameters are computed: Bracco Suisse SA Software Applications VBO

35 Perfused Area (PA, PA1, PA2) relative Perfused Area (rpa, rpa1, rpa2) Mean MIP Opacification (MIP) Mean MIP Opacification Perfused Pixel only (MIP th) Mean Median Integral PA represents the total number of pixels retained in the plaque after the processing or the area in [mm 2 ] of these pixels if the length calibration has been defined. Additionally, the rpa is expressed in [%] and corresponds to percentage of retained pixels with respect to the total pixels in the plaque ROI. For the parameters PA and rpa, the images considered during the processing are the concatenation of the two perfusion segments. For the parameters PA1 and rpa1, only the first perfusion segment is taken into account during the processing. For PA2 and rpa2, only the second perfusion segment is taken into account during the processing. The Mean MIP Opacification computes the mean value of the MIP in the ROI. It is also calculated in the lumen ROI which can serve as a reference ROI. The MIP th only takes into account the perfused pixel (after filtering). The Mean parameter corresponds to the mean value of the linearized signal inside a ROI, the Median parameter corresponds to the median value of the linearized signal inside a ROI, and the Integral parameter corresponds to the integral value of the linearized signal inside a ROI. Figure 23 - Parametric image of the perfused area Figure 23 shows the parametric image of the perfused area. In the plaque ROI, the pixels highlighted correspond to area considered as perfused. A plaque ROI must not be contaminated by enhancement coming from the lumen. It could lead to wrong perfusion area results. Time segments (baseline or perfusion) must contain images from the same plane (out of plane frames must not be included). It could lead to wrong perfusion area results. Bracco Suisse SA Software Applications VBO

36 During the baseline time segment (which aim is to compute the noise level in each plaque ROI), a plaque ROI should not be contaminated by artefacts (specular reflectors) to avoid perfusion area underestimation. Additionally, the baseline segment must be located before the contrast arrival time. Distal plaques cannot be analyzed correctly. Indeed, distal artefact creates an artificially high enhancement in the plaque MEASUREMENT ACCEPTANCE CRITERIA The accuracy of the calculated and measured parameters was verified and the following error should be taken into account: Calculated & Measured parameters f ± 15% t DVP t Tolerance ± 15% WiAUC ± 15% RT ± 15% mttl ± 15% TTP ± 15% WiR (Bolus) ± 15% WiR (Replenishment) ± 15% WiPI ± 15% WoAUC ± 15% WiWoAUC ± 15% FT ± 15% WoR ± 15% rbv ± 15% mtt ± 15% rbf ± 15% QOF ± 15% PA ± 15% rpa ± 15% PARAMETRIC IMAGING VueBox can perform spatial rendering of any perfusion parameter, in the form of a color-rendered parametric map. This map synthesizes the time sequence of images into a single parametric image. Parametric imaging may enhance the information content of the contrast examination. This technique may be particularly useful for making qualitative analyses in the course of a therapeutic monitoring performed on a given small-animal. In the example of using the destruction-replenishment technique, the efficacy of a substance inhibiting angiogenesis may be assessed by observing parametric images of relative blood volume (rbv) in a tumor, before and in the course of therapeutic treatment, reflecting the state of tumor perfusion resulting from the neovasculature. A second benefit of parametric images is the spatial visualization of tumor response to the treatment, or its effects on healthy surrounding parenchyma. Note that in order to perform qualitative analyses on the basis of parametric images, certain recommendations must be made: Bracco Suisse SA Software Applications VBO

37 the clips must represent the same anatomical cross-section from one exam to another; acquisition of contrast-ultrasound sequences must be performed using identical system settings (primarily transmit power, display settings, gain, TGC, dynamic range and postprocessing); only parametric images of the same perfusion parameter can be compared. Figure 24 - Parametric images example WORKFLOW To perform perfusion data processing: 1. click the button, 2. in the Bolus case only, accept, modify or ignore the automatic contrast arrival detection, 3. review the result in the result window RESULT WINDOW INTERFACE ELEMENTS Once the perfusion quantification processing is completed, VueBox switches from the clip editing mode to the result mode. The display-layout in the result mode comprises four quadrants (Q1-Q4). The four-quadrant representation combines all results within one display, namely Original clip (Q1); Processed clip or parametric image (Q2); Chart displaying time intensity curves (linearized and fitted signals) in each ROI (Q3); Table listing the computed parameter values in each ROI (Q4). Q1 displays the original clip and Q2 a processed clip or a parametric image, depending on the selection in the Parametric image view menu. Each parametric image has its own colormap, which is rendered in the colorbar located in the lower-right corner of Q2. For amplitude perfusion parameters, the colormap ranges from blue to red, representing low to high amplitudes, respectively. As regards time parameters, the colormap is a reversed version of the colormap used for amplitude parameters. In Q3, the colors of the traces match those of the ROI. When a ROI is moved or modified, its corresponding signals and computed values are automatically and immediately recalculated and displayed in Q4. The ROI labels may be changed by editing the data in the left column cells (Q4). For the specific case of the Plaque package, in Q3, the signal of each ROI is displayed in a multi-scale time/intensity graph (cf. Figure 22). The left scale (in white) is dedicated to the plaque ROI(s), whereas the right one (yellow) is the scale associated to the lumen ROI. Bracco Suisse SA Software Applications VBO

38 Q1 Q2 Q3 Q4 Figure 25 - User interface in result mode Control Name Function Parametric image view allows the selection of parameter to be displayed. Finally, relative measurements can be displayed in the Q4 table by checking one of the ROI as a reference (in the Ref. column). Relative values are displayed in [%] and [db] for amplitude-related parameters and in [%] for time-related parameters. Figure 26 - Quantitative parameter table When selecting DVP or DVPP parameters (i.e. in Liver DVP package) from the Parametric image view menu, the quantitative parameter table is replaced by a chart showing the DVP difference signals ADJUSTABLE DISPLAY PRESETS Above Q2, sliders are provided to adjust the gain and the dynamic range (logcompression) of the processed image displayed in Q2, in a way similar to a standard ultrasound scanner. Bracco Suisse SA Software Applications VBO

39 Slider / control Name Function Preset stores, restores and auto scales display preset (gain and dynamic range of all parametric images). Gain Dynamic range Overlay opacity controls the gain applied to the current processed image (Q2). (-60dB to +60dB) controls the dynamic range of logcompressed applied to the current processed image (Q2). (0dB to +60dB) controls the opacity of the overlay displayed on the B-Mode side (Q2) AUTO-SCALED DISPLAY PRESETS Display presets (i.e. gain & dynamic range) for each parametric image are automatically adjusted once the perfusion quantification processing is completed using the built-in auto-scaling function. However, this adjustment is to be seen as a suggestion and may need further manual fine tuning. Below, an example of a parametric image prior and after auto-scaling is applied: Figure 27 : Parametric image prior and after display presets auto-scaling STORING / LOADING DISPLAY PRESET Display preset can be stored into a dedicated library and loaded at a later time point. To store the preset for all parametric images: 1. Click the button in the preset toolbar 2. Set a name or accept the one generated by default and press the OK button Figure 28 : Storing display presets into library Bracco Suisse SA Software Applications VBO

40 To load display presets from the library: 1. Click the button in the preset toolbar 2. Select the item in the list and press the OK button Figure 29 : Loading display presets from library PARAMETRIC IMAGE OVERLAY In Q2, the B-Mode side can also displayed the parametric image by overlay. The opacity of this overlay can be increased or decreased using the opacity slider of the display settings. Figure 30 - An overlay is displayed on the B-Mode side in Q PERFUSION INSTANT DETECTION This feature is only available in the Liver DVP package (see section 4.3.4) Most representative perfusion instants (initial, mid and last) of the DVP clip are provided by VueBox as a suggestion of DVP images to be added to the patient report. Once the DVP processing is performed, perfusion instants are displayed as three red vertical bars in the difference graph (Q4) as illustrated below. These instants can be easily modified by dragging the bars to the desired instants. Bracco Suisse SA Software Applications VBO

41 Figure 31 - DVP perfusion instants ANALYSIS RESULT DATABASE Each clip associates a result database in which the whole context of each analysis result can be stored. This enables restoration of the result at a later time by selecting the corresponding clip (previously analyzed) in the start page of VueBox. Figure 32 - Result database dialog box The result database is automatically displayed when saving a result or loading a clip for which previous analyses exist. SAVING AN ANALYSIS To save the current result: 1. Click the button in the main toolbar 2. Under Save as, type the result name 3. Click the OK button. To overwrite a result: 1. Click the button in the main toolbar 2. Select a result in the list 3. Click the OK button. To remove a result: 1. Click the button in the main toolbar 2. Select a result in the list 3. Click the DELETE button. Bracco Suisse SA Software Applications VBO

42 4.15 EXPORT ANALYSIS DATA PRINCIPLE VueBox offers the possibility to export numerical, image and clip data to a user defined directory. For example, the numerical data are particularly useful for carrying out further analyses in a spreadsheet program. The image data are a set of screenshot containing both the regions of interest and parametric images. These images allow to perform qualitative comparisons between successive studies in the course of a therapeutic followup on a given patient. As a second example of qualitative analysis, the processed clips may provide a better assessment of the contrast-uptake over time. Still images or processed clips may also be useful for documentation or presentation purposes. Finally, an analysis report summarizing qualitative (i.e. still images) and quantitative (i.e. numerical data) information can be generated. The user should always review the consistency of the exported results (i.e. images, numerical data, etc.) INTERFACE ELEMENTS Some export options may not be available in all application packages. The figure below shows a screenshot of the interface elements in export mode. Figure 33: User interface in export mode Name Function Data TSV exports a tabulated text file (XLS extension) including time intensity curves and perfusion estimates. Images Full screen exports a screenshot of the front panel (All 4 quadrants). Bracco Suisse SA Software Applications VBO

43 Ultrasound image (current) Parametric images Time Intensity Curve exports the current ultrasound image with its ROIs (Quadrant 1). exports all parametric images (Quadrant 2). exports an image of the chart (Quadrant 3). Clip Original Parametric Native & Parametric exports the original clip. exports the processed clip. exports both the original and processed clips in a side-by-side view mode. Video Quality quality of the exported clip (in percent). Frame rate video frame rate of the exported clip (sub-sample factor). Analysis Report Generate report generates the analysis report and display the report generator dialog box. Folder name Save as indicates the folder name where the result files will be saved WORKFLOW To export data: 1. Click the button 2. Select a target directory in the left panel 3. Under Data, Images and Clip in the right panel, choose the type of results to export 4. Under Option, type a folder result name 5. Click the OK button in the main toolbar to export the results in the specified folder result name ANALYSIS REPORT The analysis report summarizes both qualitative (i.e. still images) and quantitative (i.e. numerical data) information in a single, customizable, easy-to-read report. The report is divided into two parts: a header and a body. The header contains the following information: Hospital-related information Patient- and exam-related information Bracco Suisse SA Software Applications VBO

44 Hospital name Patient ID Department name Patient name Professor name Physician name Phone & fax numbers Exam date Patient birth date Contrast agent used Indication for exam Hospital-related information are editable and are saved from one session to another. Patient- and exam-related information are automatically extracted from the DICOM dataset header, if present, and may be edited if not present. For the specific case of the Liver DVP package (see section 4.3.4): The body of the report contains the following information: an image of the analyzed clip including ROI, a DVPP image, three images at different DVP instants, a chart representing the average signal within available ROI, a chart representing the average difference signal within available ROI (i.e. DVP signal), an editable comment field. Otherwise, in all other cases: The body of the report contains the following information: an image of the analyzed clip including ROI, a chart representing the average signal within available ROI, the perfusion model selected, a parametric image and quantitative values, in absolute and relative terms, for each perfusion parameters, an editable comment field. Perfusion parameters can be dynamically added or removed from the analysis report, thus reducing or increasing the number of pages. The user selection is saved from one session to another. Bracco Suisse SA Software Applications VBO

45 Figure 34 - Analysis report, header modification interface Figure 35 - Analysis report, quantitative parameter selection Finally, the report can be saved into a finalized PDF file by pressing IMPORT AND EXPORT USER SETTINGS User settings such as ROI, result and display preset databases, can be exported into a single file (with 1.sharp extension) and reimported at a later time. This function may be useful for sharing results between users or when transferring the software to another computer. To export user settings: Bracco Suisse SA Software Applications VBO

Quick reference guide. MyLab50

Quick reference guide. MyLab50 Quick reference guide MyLab50 Quick reference guide MyLab50 Introduction This Quick Guide describes only the basic operating procedures for the diagnostic ultrasound MyLab50 Family, named in the following

More information

SICAT SUITE VERSION 1.0. Instructions for use SIDEXIS XG English

SICAT SUITE VERSION 1.0. Instructions for use SIDEXIS XG English SICAT SUITE VERSION 1.0 Instructions for use SIDEXIS XG English Table of contents Table of contents 1 System requirements... 3 2 Overview of SICAT Suite... 5 3 Differences between full featured mode and

More information

n o r d i c B r a i n E x Tutorial DSC Module

n o r d i c B r a i n E x Tutorial DSC Module m a k i n g f u n c t i o n a l M R I e a s y n o r d i c B r a i n E x Tutorial DSC Module Please note that this tutorial is for the latest released nordicbrainex. If you are using an older version please

More information

Echo Blaster 64/128 and LogicScan 64/128 Series Ultrasound Systems Echo Wave II Software User Manual

Echo Blaster 64/128 and LogicScan 64/128 Series Ultrasound Systems Echo Wave II Software User Manual Echo Blaster 64/128 and LogicScan 64/128 Series Ultrasound Systems Echo Wave II Software User Manual Internet page: http://www.telemed.lt Information E-mail: info@telemed.lt Ultrasound Medical Systems

More information

14 July Ver CRView V3 User Guide. 1 P a g e

14 July Ver CRView V3 User Guide. 1 P a g e Ver. 080707 CRView V3 User Guide 1 P a g e Contents Copyright notice... 3 Trademarks... 3 System requirements... 4 Required hardware... 4 Recommended hardware... 4 Installing CRView... 5 Installing from

More information

syngo.pet&ct Oncology CT Tutorial

syngo.pet&ct Oncology CT Tutorial www.siemens.com/healthcare syngo.pet&ct Oncology CT Tutorial Storyboard VA30 Answers for life. Table of contents 1 What's New in the Latest Upgrade of syngo.pet&ct Oncology? 5 2 Introduction 7 2.1 Prerequisites

More information

Sending image(s) to report Click Send Snapshot on any screen in Dolphin3D and choose the Send to Report option

Sending image(s) to report Click Send Snapshot on any screen in Dolphin3D and choose the Send to Report option Dolphin 3D Reports Sending image(s) to report Click Send Snapshot on any screen in Dolphin3D and choose the Send to Report option Creating a report step by step 1. Generate the desired images in Dolphin3D

More information

WoundManager Basic Edition v. 2.0 INSTRUCTIONS

WoundManager Basic Edition v. 2.0 INSTRUCTIONS WoundManager Basic Edition v. 2.0 INSTRUCTIONS Antonic d.o.o.(ltd.) 2012. TABLE OF CONTENTS 1. INSTALLATION... 1 1.1. Prerequisites... 1 1.2. Installing the product... 1 1.3. Location of application files...

More information

Bombardier Business Aircraft Customer Services. Technical Publications. SmartPubs Viewer 3.0 User Guide. Updated January 2013 [2013]

Bombardier Business Aircraft Customer Services. Technical Publications. SmartPubs Viewer 3.0 User Guide. Updated January 2013 [2013] Bombardier Business Aircraft Customer Services Technical Publications SmartPubs Viewer 3.0 User Guide Updated January 2013 [2013] Table of Contents Application Views... 5 Collection View... 5 Manual View...

More information

Insight: Measurement Tool. User Guide

Insight: Measurement Tool. User Guide OMERO Beta v2.2: Measurement Tool User Guide - 1 - October 2007 Insight: Measurement Tool User Guide Open Microscopy Environment: http://www.openmicroscopy.org OMERO Beta v2.2: Measurement Tool User Guide

More information

Graphic Design & Digital Photography. Photoshop Basics: Working With Selection.

Graphic Design & Digital Photography. Photoshop Basics: Working With Selection. 1 Graphic Design & Digital Photography Photoshop Basics: Working With Selection. What You ll Learn: Make specific areas of an image active using selection tools, reposition a selection marquee, move and

More information

ClinicalExpress Operator s Guide. version 6.1 for general radiography and mammography

ClinicalExpress Operator s Guide. version 6.1 for general radiography and mammography ClinicalExpress Operator s Guide version 6.1 for general radiography and mammography Copyright by VIDAR Systems Corporation. All rights reserved. No part of this publication may be reproduced, stored in

More information

User Manual Version 1.1 January 2015

User Manual Version 1.1 January 2015 User Manual Version 1.1 January 2015 - 2 / 112 - V1.1 Variegator... 7 Variegator Features... 7 1. Variable elements... 7 2. Static elements... 7 3. Element Manipulation... 7 4. Document Formats... 7 5.

More information

LOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company.

LOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company. TM LOGIQ V2 Ultrasound Part of LOGIQ Vision Series Imagination at work The brilliance of color. The simplicity of GE. Now you can add the advanced capabilities of color Doppler to patient care with the

More information

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1 IMAGE STUDIO LITE Tutorial Guide Featuring Image Studio Analysis Software Version 3.1 Notice The information contained in this document is subject to change without notice. LI-COR MAKES NO WARRANTY OF

More information

TotalLab TL100 Quick Start

TotalLab TL100 Quick Start TotalLab TL100 Quick Start Contents of thetl100 Quick Start Introduction to TL100 and Installation Instructions The Control Centre Getting Started The TL100 Interface 1D Gel Analysis Array Analysis Colony

More information

Medical Image Viewer Guide

Medical Image Viewer Guide Cloud Medical Image Management Medical Image Viewer Guide March 2016 Table of Contents Indications for Use 3 Browser Requirements 3 User Interface Overview 4-5 Study Page 6 Main Toolbar 7 Sub-Toolbars

More information

Image Quant TL (PSC 563, 537, NSC 338, 438)

Image Quant TL (PSC 563, 537, NSC 338, 438) Image Quant TL (PSC 563, 537, NSC 338, 438) Contact: Hyuk Kyu Seoh hseoh@gsu.edu Rm: PSC 537 Tel: (404) 413-5379 This software can analyze 1D gels, dot and slot blots, microplates, other basic arrays and

More information

Edupen Pro User Manual

Edupen Pro User Manual Edupen Pro User Manual (software for interactive LCD/LED displays and monitors) Ver. 3 www.ahatouch.com Some services in Edupen Pro require dual touch capability. In order to use dual touch, your computer

More information

BLUEPRINT READER 2010 INSTALLATION & USER GUIDE 09OCT09

BLUEPRINT READER 2010 INSTALLATION & USER GUIDE 09OCT09 BLUEPRINT READER 2010 INSTALLATION & USER GUIDE 09OCT09 The information in this document is subject to change without notice and should not be construed as a commitment by Blueprint Software Systems Inc.

More information

VIMED JWEB Manual. Victorian Stroke Telemedicine. Version: 1.0. Created by: Grant Stephens. Page 1 of 17

VIMED JWEB Manual. Victorian Stroke Telemedicine. Version: 1.0. Created by: Grant Stephens. Page 1 of 17 VIMED JWEB Manual Victorian Stroke Telemedicine Version: 1.0 Created by: Grant Stephens Page 1 of 17 1 Table of Contents 1 Table of Contents... 2 2 What is JWEB?... 4 3 Accessing JWEB... 4 3.1 For Mac

More information

Learn Image Segmentation Basics with Hands-on Introduction to ITK-SNAP. RSNA 2016 Courses RCB22 and RCB54

Learn Image Segmentation Basics with Hands-on Introduction to ITK-SNAP. RSNA 2016 Courses RCB22 and RCB54 Learn Image Segmentation Basics with Hands-on Introduction to ITK-SNAP RSNA 2016 Courses RCB22 and RCB54 RCB22 Mon, Nov 28 10:30-12:00 PM, Room S401CD RCB54 Thu, Dec 1 2:30-4:30 PM, Room S401CD Presenters:

More information

KCS Motion. Video Motion Analysis Software

KCS Motion. Video Motion Analysis Software Video Motion Analysis Software Software and supporting material is property of G. Mason, Seattle University, 2007 Overview Overview KCS Motion tracks moving objects in a video clip and analyzes their position,

More information

VXvue User Manual (For Human Use)

VXvue User Manual (For Human Use) VXvue User Manual (For Human Use) Page 2 of 90 Revision History Version Date Description 1.0 2012-03-20 Initial Release Page 3 of 90 Contents Safety and Regulatory... 8 Safety Notice... 8 1. Introduction...

More information

for ArcSketch Version 1.1 ArcSketch is a sample extension to ArcGIS. It works with ArcGIS 9.1

for ArcSketch Version 1.1 ArcSketch is a sample extension to ArcGIS. It works with ArcGIS 9.1 ArcSketch User Guide for ArcSketch Version 1.1 ArcSketch is a sample extension to ArcGIS. It works with ArcGIS 9.1 ArcSketch allows the user to quickly create, or sketch, features in ArcMap using easy-to-use

More information

Virtual MODELA USER'S MANUAL

Virtual MODELA USER'S MANUAL Virtual MODELA USER'S MANUAL Virtual MODELA is a program that simulates the movement of the tool on the screen. Contents Contents Part 1 Introduction 1-1 System Requirements... 4 1-2 Overview of Virtual

More information

Keynote 08 Basics Website:

Keynote 08 Basics Website: Website: http://etc.usf.edu/te/ Keynote is Apple's presentation application. Keynote is installed as part of the iwork suite, which also includes the word processing program Pages and the spreadsheet program

More information

Table of Contents. Logos Imaging Application User s Manual Version Page 1

Table of Contents. Logos Imaging Application User s Manual Version Page 1 Table of Contents About... 4 System Requirements... 5 Uninstall Previous Versions... 5 Install LIA 6.0... 6 Install the Device Drivers... 13 Register... 14 Getting Help... 14 Technical Support... 14 Workspace

More information

ENVI Classic Tutorial: Introduction to ENVI Classic 2

ENVI Classic Tutorial: Introduction to ENVI Classic 2 ENVI Classic Tutorial: Introduction to ENVI Classic Introduction to ENVI Classic 2 Files Used in This Tutorial 2 Getting Started with ENVI Classic 3 Loading a Gray Scale Image 3 ENVI Classic File Formats

More information

ClinicalConnect TM eunity TM Training Guide

ClinicalConnect TM eunity TM Training Guide ClinicalConnect TM eunity TM Training Guide October, 2013 Launch eunity TM from ClinicalConnect TM Search and select the patient whose record you wish to view. Navigate to the Radiology module in ClinicalConnect

More information

A QUICK TOUR OF ADOBE ILLUSTRATOR CC (2018 RELEASE)

A QUICK TOUR OF ADOBE ILLUSTRATOR CC (2018 RELEASE) A QUICK TOUR OF ADOBE ILLUSTRATOR CC (2018 RELEASE) Lesson overview In this interactive demonstration of Adobe Illustrator CC (2018 release), you ll get an overview of the main features of the application.

More information

Photoshop / Editing paths

Photoshop / Editing paths Photoshop / Editing paths Path segments, components, and points Select a path Adjust path segments Add or delete anchor points Convert between smooth points and corner points Adjust path components Path

More information

ezimagex2 User s Guide Version 1.0

ezimagex2 User s Guide Version 1.0 ezimagex2 User s Guide Version 1.0 Copyright and Trademark Information The products described in this document are copyrighted works of AVEN, Inc. 2015 AVEN, Inc. 4595 Platt Rd Ann Arbor, MI 48108 All

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd Copyright 2007-2009 Cortex Global Table of contents: Introduction... 3 1. Login... 3 1.1 Advanced login options... 4 2. Preview... 5 2.1 Main menu... 6 2.2 Camera list... 6 2.3 Main display... 6 2.4 Maps...

More information

L E S S O N 2 Background

L E S S O N 2 Background Flight, Naperville Central High School, Naperville, Ill. No hard hat needed in the InDesign work area Once you learn the concepts of good page design, and you learn how to use InDesign, you are limited

More information

ENVI Tutorial: Introduction to ENVI

ENVI Tutorial: Introduction to ENVI ENVI Tutorial: Introduction to ENVI Table of Contents OVERVIEW OF THIS TUTORIAL...1 GETTING STARTED WITH ENVI...1 Starting ENVI...1 Starting ENVI on Windows Machines...1 Starting ENVI in UNIX...1 Starting

More information

Manual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis

Manual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis Phone: (888) 765-9735 WWW.MINDWARETECH.COM User Reference Guide Manual Analysis Application Electromyography Analysis (EMG) Copyright 2014 by MindWare Technologies LTD. All Rights Reserved. 1 Phone: (614)

More information

Keys for selecting tools

Keys for selecting tools Keys for selecting tools Use these shortcuts in the Tools panel. In most cases, you can momentarily switch tools by holding down the keyboard shortcut for the tool. Selection tool V V Rotation tool W W

More information

10 Working With Setup Tools

10 Working With Setup Tools 10 Working With Setup Tools Setup Tools Overview The Setup window allows you to set defaults and control various functions of the Terason software. The Setup window tabs display sets of controls for defaults

More information

Motic Images Plus 3.0 ML Software. Windows OS User Manual

Motic Images Plus 3.0 ML Software. Windows OS User Manual Motic Images Plus 3.0 ML Software Windows OS User Manual Motic Images Plus 3.0 ML Software Windows OS User Manual CONTENTS (Linked) Introduction 05 Menus and tools 05 File 06 New 06 Open 07 Save 07 Save

More information

Imaging Guide Pancreatic Imaging

Imaging Guide Pancreatic Imaging Imaging Guide Guide to Small Animal Pancreatic Imaging using the Vevo 2100 Imaging System Ver 1.0 Guide to Small Animal Pancreatic Imaging using the Vevo 2100 Imaging System Course Objectives: This guide

More information

SICAT SUITE VERSION 1.1. Instructions for use English

SICAT SUITE VERSION 1.1. Instructions for use English SICAT SUITE VERSION 1.1 Instructions for use English TABLE OF CONTENTS TABLE OF CONTENTS 1 Used icons and highlighting... 4 2 Safety information... 5 2.1 Identification of danger levels... 6 2.2 Qualification

More information

DriveWizard Plus Instruction Manual

DriveWizard Plus Instruction Manual DriveWizard Plus Instruction Manual To properly use the product, read this manual thoroughly. MANUAL NO. TOEP C730600 20C Table of Contents Safety Symbols and Markings...4 Manual Overview...5 Related Manuals...5

More information

Synoptics Limited reserves the right to make changes without notice both to this publication and to the product that it describes.

Synoptics Limited reserves the right to make changes without notice both to this publication and to the product that it describes. GeneTools Getting Started Although all possible care has been taken in the preparation of this publication, Synoptics Limited accepts no liability for any inaccuracies that may be found. Synoptics Limited

More information

Colony Counting User Manual A D I V I S I O N O F S Y N O P T I C S L T D

Colony Counting User Manual A D I V I S I O N O F S Y N O P T I C S L T D ProtoCOL Colony Counting User Manual S Y N B I O S I S A D I V I S I O N O F S Y N O P T I C S L T D All possible care has been taken in the preparation of this publication, but Synoptics Limited accepts

More information

Creating a Title Block & Border Using Chief Architect. Architectural Design & Residential Construction Penncrest High School

Creating a Title Block & Border Using Chief Architect. Architectural Design & Residential Construction Penncrest High School Creating a Title Block & Border Using Chief Architect Architectural Design & Residential Construction Penncrest High School 2017-2018 Select New Layout to begin designing your Title Block. Note: Once the

More information

Ultrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software

Ultrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software Ultrasound Q-Station software Streamlined workflow solutions Philips Q-Station ultrasound workspace software Managing your off-cart workf low Everyone is being asked to do more with fewer resources it

More information

Logger Pro Resource Sheet

Logger Pro Resource Sheet Logger Pro Resource Sheet Entering and Editing Data Data Collection How to Begin How to Store Multiple Runs Data Analysis How to Scale a Graph How to Determine the X- and Y- Data Points on a Graph How

More information

CONTENT PLAYER 9.6_CA_BBP_EN_1.0

CONTENT PLAYER 9.6_CA_BBP_EN_1.0 CONTENT PLAYER 9.6_CA_BBP_EN_1.0 COPYRIGHT Copyright 1998, 2009, Oracle and/or its affiliates. All rights reserved. Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Other names

More information

MindWare Electromyography (EMG) Analysis User Reference Guide Version Copyright 2011 by MindWare Technologies LTD. All Rights Reserved.

MindWare Electromyography (EMG) Analysis User Reference Guide Version Copyright 2011 by MindWare Technologies LTD. All Rights Reserved. MindWare Electromyography (EMG) Analysis User Reference Guide Version 3.0.12 Copyright 2011 by MindWare Technologies LTD. All Rights Reserved. MindWare EMG 3.0.12 User Guide Internet Support E-mail: sales@mindwaretech.com

More information

10 Working With Setup Tools

10 Working With Setup Tools 10 Working With Setup Tools The Setup window allows you to set defaults and control various functions of the Terason software. The Setup window tabs display sets of controls for defaults and other settings.

More information

VisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents

VisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents VisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents 1 Objective Part Number: 11902 The objective of the 3D Tumor Imaging using the MicroMarker Non-Targeted

More information

Introducing Gupta Report Builder

Introducing Gupta Report Builder Business Reporting Chapter 1 Introducing Gupta Report Builder You can use Report Builder to design reports. This chapter describes: Our approach to building reports. Some of the reports you can build.

More information

American Board of Orthodontics (ABO) Model Conversion Utility User Guide Updated 7/2/2014. Authorized Users

American Board of Orthodontics (ABO) Model Conversion Utility User Guide Updated 7/2/2014. Authorized Users Authorized Users American Board of Orthodontics (ABO) Model Conversion Utility User Guide Updated 7/2/2014 All orthodontists who have made application for ABO examination will be authorized to register

More information

How to create interactive documents

How to create interactive documents Adobe InDesign Guide How to create interactive documents You can use Adobe InDesign to create dynamic web content or interactive documents. InDesign supports export to web-ready HTML or interactive PDF.

More information

Voxar 3D ColonMetrix. Reference Guide

Voxar 3D ColonMetrix. Reference Guide Voxar 3D ColonMetrix Reference Guide The software described in this document is furnished under a license, and may be used or copied only according to the terms of such license. Toshiba means, Toshiba

More information

MiBio Reference Manual

MiBio Reference Manual MiBio Reference Manual www.microtek.com Copyright 2012 by Microtek International, Inc. All rights reserved. Trademarks Microtek, ScanMaker, ArtixScan, ScanWizard and ColoRescue are trademarks or registered

More information

Stroke Quantification Tool (Sonia) Ver User Manual

Stroke Quantification Tool (Sonia) Ver User Manual Stroke Quantification Tool (Sonia) Ver. 1.0 User Manual English. 12/2016 Rev. 1.0 www.wakeup-stroke.eu 1 Table of Contents 1. Introduction...3 2. Installation...4 3. Data Import...5 4. Registration...7

More information

CHAPTER 3 RETINAL OPTIC DISC SEGMENTATION

CHAPTER 3 RETINAL OPTIC DISC SEGMENTATION 60 CHAPTER 3 RETINAL OPTIC DISC SEGMENTATION 3.1 IMPORTANCE OF OPTIC DISC Ocular fundus images provide information about ophthalmic, retinal and even systemic diseases such as hypertension, diabetes, macular

More information

cief Data Analysis Chapter Overview Chapter 12:

cief Data Analysis Chapter Overview Chapter 12: page 285 Chapter 12: cief Data Analysis Chapter Overview Analysis Screen Overview Opening Run Files How Run Data is Displayed Viewing Run Data Data Notifications and Warnings Checking Your Results Group

More information

3DMMVR REFERENCE MANUAL V 0.81

3DMMVR REFERENCE MANUAL V 0.81 3DMMVR REFERENCE MANUAL V 0.81 Page 1 of 30 Index: 1.0 System Requirements...5 1.1 System Processor...5 1.2 System RAM...5 1.3 Graphics Card...5 1.4 Operating System...5 2.0 Conventions...6 2.1 Typographic

More information

Funasset Limited Foundry House Foundry Road Taunton Somerset TA1 1JJ. Tel: +44 (0) Fax: +44 (0) mailmarkup.com funasset.

Funasset Limited Foundry House Foundry Road Taunton Somerset TA1 1JJ. Tel: +44 (0) Fax: +44 (0) mailmarkup.com funasset. Funasset Limited Foundry House Foundry Road Taunton Somerset TA1 1JJ Tel: +44 (0)1823 365864 Fax: +44 (0)1823 277266 mailmarkup.com funasset.com Copyright 2012 Funasset Limited. All rights reserved. Products

More information

AORTA CTA VPMC-12419

AORTA CTA VPMC-12419 AORTA CTA VPMC-12419 Workflow Overview: The Aorta can be post-processed in various ways. Auto Bone Removal and Vessel Pick provide a quick overview of the entire Aorta. Vessel Probe creates a centerline

More information

AEMLog Users Guide. Version 1.01

AEMLog Users Guide. Version 1.01 AEMLog Users Guide Version 1.01 INTRODUCTION...2 DOCUMENTATION...2 INSTALLING AEMLOG...4 AEMLOG QUICK REFERENCE...5 THE MAIN GRAPH SCREEN...5 MENU COMMANDS...6 File Menu...6 Graph Menu...7 Analysis Menu...8

More information

Student Quick Reference Guide

Student Quick Reference Guide Student Quick Reference Guide How to use this guide The Chart Student Quick Reference Guide is a resource for PowerLab systems in the classroom laboratory. The topics in this guide are arranged to help

More information

ADOBE ILLUSTRATOR CS3

ADOBE ILLUSTRATOR CS3 ADOBE ILLUSTRATOR CS3 Chapter 2 Creating Text and Gradients Chapter 2 1 Creating type Create and Format Text Create text anywhere Select the Type Tool Click the artboard and start typing or click and drag

More information

IDL Tutorial. Working with Images. Copyright 2008 ITT Visual Information Solutions All Rights Reserved

IDL Tutorial. Working with Images. Copyright 2008 ITT Visual Information Solutions All Rights Reserved IDL Tutorial Working with Images Copyright 2008 ITT Visual Information Solutions All Rights Reserved http://www.ittvis.com/ IDL is a registered trademark of ITT Visual Information Solutions for the computer

More information

Expression Design Lab Exercises

Expression Design Lab Exercises Expression Design Lab Exercises Creating Images with Expression Design 2 Beaches Around the World (Part 1: Beaches Around the World Series) Information in this document, including URL and other Internet

More information

Adobe Illustrator CS Design Professional GETTING STARTED WITH ILLUSTRATOR

Adobe Illustrator CS Design Professional GETTING STARTED WITH ILLUSTRATOR Adobe Illustrator CS Design Professional GETTING STARTED WITH ILLUSTRATOR Chapter Lessons Create a new document Explore the Illustrator window Create basic shapes Apply fill and stroke colors to objects

More information

MANUAL NO. OPS647-UM-151 USER S MANUAL

MANUAL NO. OPS647-UM-151 USER S MANUAL MANUAL NO. OPS647-UM-151 USER S MANUAL Software Usage Agreement Graphtec Corporation ( Graphtec ) hereby grants the purchaser and authorized User (the User ) the right to use the software (the Software

More information

XPEL DAP SUPPORT. DAP Tool List & Overview DESCRIPTION ICON/TOOL (SHORTCUT)

XPEL DAP SUPPORT. DAP Tool List & Overview DESCRIPTION ICON/TOOL (SHORTCUT) Pointer (S) Left-click on individual entities to add them to the current selection (selected entities will turn red). If the entity selected is a member of a group, the entire group will be added to the

More information

Version 4.0. Quick Start Guide For the Odyssey CLx Infrared Imaging System

Version 4.0. Quick Start Guide For the Odyssey CLx Infrared Imaging System Version 4.0 Quick Start Guide For the Odyssey CLx Infrared Imaging System 1 Install the Image Studio Software Important: You must be logged in to the Windows Operating System using an Administrator type

More information

ACUSON P300 Ultrasound System Control Panel Diagram

ACUSON P300 Ultrasound System Control Panel Diagram www.siemens.com ACUSON P300 Ultrasound System Control Panel Diagram 1 Power On / Off 1 2 TGC Controls 3 Left Mouse Click 4 Action 4 7 5 Right Mouse Click 6 Trackball 2 3 6 5 8 7 Pointer 8 Freeze 16 Color

More information

Solo 4.6 Release Notes

Solo 4.6 Release Notes June9, 2017 (Updated to include Solo 4.6.4 changes) Solo 4.6 Release Notes This release contains a number of new features, as well as enhancements to the user interface and overall performance. Together

More information

Avigilon Control Center Web Client User Guide

Avigilon Control Center Web Client User Guide Avigilon Control Center Web Client User Guide Version: 4.12 Standard PDF-WEBCLIENT-S-E-Rev2 Copyright 2013 Avigilon. All rights reserved. The information presented is subject to change without notice.

More information

Adobe InDesign CS6 Tutorial

Adobe InDesign CS6 Tutorial Adobe InDesign CS6 Tutorial Adobe InDesign CS6 is a page-layout software that takes print publishing and page design beyond current boundaries. InDesign is a desktop publishing program that incorporates

More information

4. TROUBLESHOOTING PREVIOUS VERSIONS RUN LOLITRACK ALWAYS AS ADMIN WIBU SOFTWARE PROTECTION... 30

4. TROUBLESHOOTING PREVIOUS VERSIONS RUN LOLITRACK ALWAYS AS ADMIN WIBU SOFTWARE PROTECTION... 30 Version 4.2.0 CONTENTS 1. GETTING STARTED... 2 2. TYPICAL APPLICATIONS... 4 3. USER GUIDE... 5 3.1 SINGLE OBJECT MODE... 7 3.2 SINGLE ARENA MODE... 12 3.3 EVENT RECORDER... 19 3.4 BATCH TRACKING... 21

More information

TexRAD Research Version Client User Guide Version 3.9

TexRAD Research Version Client User Guide Version 3.9 Imaging tools for medical decision makers Cambridge Computed Imaging Ltd Grange Park Broadway Bourn Cambridge CB23 2TA UK TexRAD Research Version Client User Guide Version 3.9 Release date 23/05/2016 Number

More information

Thermo Scientific. GRAMS Envision. Version 2.1. User Guide

Thermo Scientific. GRAMS Envision. Version 2.1. User Guide Thermo Scientific GRAMS Envision Version 2.1 User Guide 2013 Thermo Fisher Scientific Inc. All rights reserved. Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase

More information

Press the Plus + key to zoom in. Press the Minus - key to zoom out. Scroll the mouse wheel away from you to zoom in; towards you to zoom out.

Press the Plus + key to zoom in. Press the Minus - key to zoom out. Scroll the mouse wheel away from you to zoom in; towards you to zoom out. Navigate Around the Map Interactive maps provide many choices for displaying information, searching for more details, and moving around the map. Most navigation uses the mouse, but at times you may also

More information

Crop Counting and Metrics Tutorial

Crop Counting and Metrics Tutorial Crop Counting and Metrics Tutorial The ENVI Crop Science platform contains remote sensing analytic tools for precision agriculture and agronomy. In this tutorial you will go through a typical workflow

More information

Contents. Introduction... iii. CHAPTER 1 - Getting Started... 5

Contents. Introduction... iii. CHAPTER 1 - Getting Started... 5 Transducer Characterization User s Guide Version 5 5 1 build 12 or later UTEX Scientific Instruments Inc support@utex com Winspect Transducer Characterization User s Guide Contents Table of Contents and

More information

SIVIC GUI Overview. SIVIC GUI Layout Overview

SIVIC GUI Overview. SIVIC GUI Layout Overview SIVIC GUI Overview SIVIC GUI Layout Overview At the top of the SIVIC GUI is a row of buttons called the Toolbar. It is a quick interface for loading datasets, controlling how the mouse manipulates the

More information

When dragging out a marquee: Shift toggles the corner selection

When dragging out a marquee: Shift toggles the corner selection VECTORSCRIBE DYNAMIC CORNERS When dragging out a marquee: Esc cancels the marquee When dragging out a marquee: Shift toggles the corner selection When dragging out a marquee: Option+Alt adds corners to

More information

Chapter 1. Getting to Know Illustrator

Chapter 1. Getting to Know Illustrator Chapter 1 Getting to Know Illustrator Exploring the Illustrator Workspace The arrangement of windows and panels that you see on your monitor is called the workspace. The Illustrator workspace features

More information

Gallios TM Quick Reference

Gallios TM Quick Reference Gallios TM Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic

More information

VHSE - COMPUTERISED OFFICE MANAGEMENT MODULE III - Communication and Publishing Art - PageMaker

VHSE - COMPUTERISED OFFICE MANAGEMENT MODULE III - Communication and Publishing Art - PageMaker INTRODUCTION : It is one Adobe PageMaker 7.0 software is the ideal page layout program for business, education, and small- and home-office professionals who want to create high-quality publications such

More information

Product information. Hi-Tech Electronics Pte Ltd

Product information. Hi-Tech Electronics Pte Ltd Product information Introduction TEMA Motion is the world leading software for advanced motion analysis. Starting with digital image sequences the operator uses TEMA Motion to track objects in images,

More information

Adobe Photoshop Sh S.K. Sublania and Sh. Naresh Chand

Adobe Photoshop Sh S.K. Sublania and Sh. Naresh Chand Adobe Photoshop Sh S.K. Sublania and Sh. Naresh Chand Photoshop is the software for image processing. With this you can manipulate your pictures, either scanned or otherwise inserted to a great extant.

More information

This is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up.

This is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up. The Volume Strikes Back Press the (4D) button. This is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up. In the Left GUI (Graphic User Interface), you

More information

CAPTURE. USER GUIDE v1

CAPTURE. USER GUIDE v1 CAPTURE USER GUIDE v1 INTRODUCTION About The Logitech Capture app makes creating content with your webcam as easy as lights, camera, Capture. Start recording high-quality videos the second you plug in

More information

v Annotation Tools GMS 10.4 Tutorial Use scale bars, North arrows, floating images, text boxes, lines, arrows, circles/ovals, and rectangles.

v Annotation Tools GMS 10.4 Tutorial Use scale bars, North arrows, floating images, text boxes, lines, arrows, circles/ovals, and rectangles. v. 10.4 GMS 10.4 Tutorial Use scale bars, North arrows, floating images, text boxes, lines, arrows, circles/ovals, and rectangles. Objectives GMS includes a number of annotation tools that can be used

More information

GDL Toolbox 2 Reference Manual

GDL Toolbox 2 Reference Manual Reference Manual Archi-data Ltd. Copyright 2002. New Features Reference Manual New Save GDL command Selected GDL Toolbox elements can be exported into simple GDL scripts. During the export process, the

More information

Selective Space Structures Manual

Selective Space Structures Manual Selective Space Structures Manual February 2017 CONTENTS 1 Contents 1 Overview and Concept 4 1.1 General Concept........................... 4 1.2 Modules................................ 6 2 The 3S Generator

More information

BDM s Annotation User Guide

BDM s Annotation User Guide ETS :Foothill De Anza CC District April 17, 2014 1 BDM s Annotation User Guide Users with Read/Write access can annotate (markup) documents if they retrieve the document using Microsoft s Internet Explorer

More information

StickFont Editor v1.01 User Manual. Copyright 2012 NCPlot Software LLC

StickFont Editor v1.01 User Manual. Copyright 2012 NCPlot Software LLC StickFont Editor v1.01 User Manual Copyright 2012 NCPlot Software LLC StickFont Editor Manual Table of Contents Welcome... 1 Registering StickFont Editor... 3 Getting Started... 5 Getting Started...

More information

Using IPACS Webserver:

Using IPACS Webserver: Using IPACS Webserver: Logging On: The IPACS Webserver can be accessed from any PC with internet connectivity. 1. Open Internet Explorer or your internet service provider. 2. Type the IPACS web address

More information

Copyright (C) 2001 Roland DG Corporation

Copyright (C) 2001 Roland DG Corporation User's Manual Unauthorized copying or transferal, in whole or in part, of this manual is prohibited. The contents of this operation manual and the specifications of this product are subject to change without

More information

Software User s Manual

Software User s Manual 1 Software User s Manual CONTENTS About the manual 2 Navigating the manual 3 CUSTOMIZING 4 Opening the control panel 4 Control panel overview 5 Calibrating the pen display 7 Adjusting pitch and phase (VGA

More information

2010 by Microtek International, Inc. All rights reserved.

2010 by Microtek International, Inc. All rights reserved. 2010 by Microtek International, Inc. All rights reserved. Microtek and DocWizard are trademarks of Microtek International, Inc. Windows is a registered trademark of Microsoft Corporation. All other products

More information