SANsurfer FC HBA CLI User s Guide

Size: px
Start display at page:

Download "SANsurfer FC HBA CLI User s Guide"

Transcription

1 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters N H

2 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document. Apple, Finder, Mac O, Macintosh, Power Mac, Panther, Tiger, and afari are registered trademarks of Apple, Inc. AMD is a registered trademark of Advanced Micro Devices, Inc. Cisco Nexus is a trademark of Cisco ystems, Inc. EMC is a registered trademark of EMC Corporation. Intel and Pentium are trademarks of Intel Corporation. Linux is a registered trademark of Linus Torvalds. Microsoft, Windows, Windows 2000 operating system, Windows erver 2003 and 2008 operating systems, Windows XP Professional operating system, and Windows Vista operating system are registered trademarks of Microsoft Corporation. Novell, NetWare, and UE are registered trademarks of Novell, Inc. IBM and PowerPC are registered trademarks of International Business Machines Corporation. QLogic, the QLogic logo, QLA, and ANsurfer are registered trademarks of QLogic Corporation. Red Hat is a registered trademark of Red Hat, Inc. olaris is a registered trademark of un Microsystems, Inc. PARC is a registered trademark of PARC International, Inc. in the UA and other countries. tuffit is a registered trademark of mith Micro oftware, Inc. VMware is a registered trademark of VMware, Inc. All other brand and product names are trademarks or registered trademarks of their respective owners. Revision A, August 20, 2004 Revision B, eptember 28, 2005 Revision C, June 7, 2006 Revision D, October 1, 2006 Revision E, February 1, 2007 Revision F, February 29, 2008 Revision G, June 30, 2008 Revision H, July 16, 2008 Document Revision History QLogic Corporation. All Rights Reserved Worldwide. First Published: August 2004 QLogic Corporation, Aliso Viejo Parkway, Aliso Viejo, CA 92656, (800) or (949) Page ii PRELIMINARY N H

3 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Changes ections Affected Revision H Changes: Removed note re Windows TORport driver version compatibility. FCoE Utility on page 4-64 Revision G Changes: Applied new QLogic book template. Modified guide s subtitle. Added note regarding messages displayed for unknown and unsupported HBAs. All Command Line Interface for QLogic FC and FCoE Adapters upported QLogic HBAs on page 1-4 Updated list of supported operating systems. upported Operating ystems on page 1-4 Corrected NPIV WWPN byte changes. Virtual Menu (Command Line Option -vp) on page 4-90 and -vp (Virtual Port) on page 5-43 Added QLE8052 to list of supported HBAs. upported QLogic HBAs on page 1-4 Added FCoE display and configuration information for QLE8042 HBA. Added introductions to the Utilities Menu, Beacon Menu, and Diagnostics Menu sections. Rearranged Utilities Menu: HBA Parameters Template section. HBA Information Menu (Command Line Option -i) on page 4-18 HBA Information (Command Line Option -i) on page 4-20 HBA Parameters Menu on page 4-23 HBA Parameters (Per FCoE Engine) on page 4-31 Utilities Menu on page 4-59, Beacon Menu on page 4-67, and Diagnostics Menu (Command Line Options -kl, -kr, and -dm) on page 4-69 HBA Parameters Template (Per HBA or All HBAs) (Command Line Option -n and OEM Name) on page 4-61 Added new FCoE Utility menu information. FCoE Utility on page 4-64 Removed Update Boot Code Only and Update FW Only options from Flash Update. Added FCoE command line information to Help menu. Added XML outputs for FCoE commands. Flash Update (Per HBA Port or All HBAs) (Command Line Option -b) on page 4-60 and Table E-1 (Command Line Option -b) Help Menu (Command Line Option -h) on page 4-93 Appendix A: XML Format 1, Appendix B: XML Format 2 N H Page iii

4 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Modified error codes and added new error codes (for FCoE) to exit/error codes appendices. Added FCoe help commands to appendix. Added glossary entries. Appendix C: Interactive Exit Codes, Appendix D: Non-interactive Error Codes Appendix E: Help Commands Glossary Revision F Changes: Changed NVRAM to HBA Parameters. Changed Option ROM to Flash. Changed HBA No. to HBA Instance. Changed FF DMI to HBA transceiver details. All All All All Updated supported QLogic HBA list. upported QLogic HBAs on page 1-4 Updated supported operating system list. upported Operating ystems on page 1-4 All non-interactive information moved from ection 4 to ection 5. ection 4, ection 5 Command line options put in alphabetical order. Table 2-1, ection 4 Added Appendix B: XML Format 2. Added port virtualization (NPIV) information. Appendix B Virtual Menu (Command Line Option -vp) on page 4-90, -vp (Virtual Port) on page 5-43 Added support for Red Hat Linux REL 5.1. Linux Installation on page 3-9 Removed installation/uninstallation instructions for olaris PARC 6 and 7. olaris Installation on page 3-9 Added O LUN Name (olaris and Linux). Target/LUN List Menu (Command Line Options -t and -l) on page 4-34 Added guide overview section, including a description of what s in the guide and documentation conventions used. Added interactive mode exit codes listing. Moved tables other than help commands from Help Commands appendix to appropriate interactive commands sections. Expanded iidma settings information. How this Guide is Organized on page 1-2 Appendix C ection 4 Target Link peed or iidma ettings Menu (Command Line Option -q) on page 4-42 Page iv PRELIMINARY N H

5 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Added Virtual Menu information. Virtual Menu (Command Line Option -vp) on page 4-90 Expanded HBA parameter templates information. Expanded diagnostic testing information. HBA Parameters Template (Per HBA or All HBAs) (Command Line Option -n and OEM Name) on page 4-61 Diagnostics Menu (Command Line Options -kl, -kr, and -dm) on page 4-69 N H Page v

6 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Page vi PRELIMINARY N H

7 Table of Contents 1 Introduction Intended Audience How this Guide is Organized Typographic Conventions Related Materials upported QLogic HBAs upported Operating ystems ystem Requirements Hardware Requirements oftware Requirements Unsupported Features License Agreements Technical upport Availability Training Contact Information Getting tarted tarting Interactive Mode tarting Non-interactive Mode Terminology Installing and Uninstalling ANsurfer FC HBA CLI Downloading the Installation Package Installing ANsurfer FC HBA CLI Windows Installation tandard (GUI) Installation Command Line Installation Linux Installation olaris Installation olaris PARC 8, 9, 10 Installation olaris x86 9 and 10 Installation N H Page vii

8 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Macintosh Installation tandard (GUI) Installation Command Line Installation Uninstalling ANsurfer FC HBA CLI Windows Uninstall tandard (GUI) Uninstall Command Line Uninstall Linux Uninstall olaris Uninstall olaris PARC 8, 9, and 10 Uninstall olaris x86 8, 9, and 10 Uninstall Macintosh Uninstall Interactive Commands General Information Menu (Command Line Option -g) Host Information (Command Line Option -g) Host Topology (Command Line Option -tp -topology) Display (Host Topology) (Command Line Option -tp -topology) ave As Txt File (Command Line Option -b) ave As XML File Generate Report (Command Line Option -z) Generate Report (Per HBA Port) Generate Report (All HBAs) (Command Line Option -z) Refresh HBA Information Menu (Command Line Option -i) HBA General Information (per HBA Port) HBA Information (Command Line Option -i) HBA Alias (Command Line Option -ha) HBA Port Alias (Command Line Option -pa) HBA VPD Information (Command Line Option -l and Reserved Word vpd ) HBA Information (All HBAs) Information HBA Parameters Menu HBA Parameters (Per HBA Port) Display HBA Parameters (Command Line Option -c#) Configure HBA Parameters (Command Line Option -n) Restore Defaults Page viii N H

9 A ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters HBA Parameters (Per FCoE Engine) Display FCoE Parameters Configure FCoE Parameters HBA Parameters (All HBAs) Target/LUN List Menu (Command Line Options -t and -l) Target/LUN List (Per HBA Port) Per Target/LUN Per Target/All LUNs All Targets Target/LUN List (All HBAs) Individual Target Individual LUN All Targets All Target(s) All LUN(s) Target Link peed or iidma ettings Menu (Command Line Option -q) Configuring the iidma ettings HBA Port Instance HBA Port Advanced Configuration Target Link peed: All HBAs Target Link peed: All HBAs, Basic Configuration Target Link peed: All HBAs, Advanced Configuration iidma ettings: Disk iidma: All HBAs Target Persistent Bindings Menu (Command Line Option -p) Target Persistent Bindings (Per HBA Port) (Command Line Option -p) Display Target Persistent Binding (Command Line Option -p) Target Persistent Bindings: Bind Target(s) (Command Line Option -p) Target Persistent Binding: Unbind Targets (Command Line Option -p) Target Persistent Binding (All HBAs) Display Target Persistent Binding Target Persistent Binding: Bind Targets Target Persistent Binding: Unbind Targets elective LUNs Menu (Command Line Option -m) elective LUNs (Per HBA Port) N H Page ix

10 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters elective LUNs (All HBAs) Display LUN Configuration Manual Configure LUNs Auto Configure LUNs Boot Device Menu (Command Line Option -e) HBA Port Instance Boot Device(s) (Per HBA Port) Configure Boot Device(s) Boot Device(s) (All HBAs) Driver ettings Menu (Command Line Option -fg) Utilities Menu Flash Update (Per HBA Port or All HBAs) (Command Line Option -b) Flash ave (Per HBA Port) (Command Line Option -b and Reserved Word save ) HBA Parameters Update (Per HBA Port or All HBAs) (Command Line Option -r) HBA Parameters ave (Per HBA Port) (Command Line Option -r and Reserved Word save ) HBA Parameters Template (Per HBA or All HBAs) (Command Line Option -n and OEM Name) Driver Update (Command Line Option -d) FCoE Utility Update Firmware tats Menu Logs Menu Driver Rescan (Command Line Option -rs) Beacon Menu Locate HBA: HBA Beacon (Command Line Option -a) Locate Target(s): Target Beacon (Command Line Option -tb) Beacon elected Target(s) Diagnostics Menu (Command Line Options -kl, -kr, and -dm) Diagnostics Loopback Test (Command Line Option -kl) Configure Loopback Test Parameters Run a Loopback Test Diagnostics Read/Write Buffer Test Configure Read/Write Test Parameters Run Read/Write Buffer Test Page x N H

11 A ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Diagnostics Transceiver Details: DMI (Command Line Option -dm) Transceiver Details: General Transceiver Details: Details tatistics Menu (Command Line Options -gs and -ls) HBA tatistics: Monitoring (Command Line Option -gs) Configuration how HBA tatistics Link tatus (Command Line Option -ls) Configuration how Link tatus Virtual Menu (Command Line Option -vp) Virtual Menu for HBA Instance List Virtual Port(s) Delete Virtual Port(s) Create Virtual Port(s) Help Menu (Command Line Option -h) Contents Exit Codes About Non-interactive Commands Display ystem Information (Command Line Options -g, -z, and -tp) Host Information (Command Line Option -g) Host Configuration (Command Line Option -z) Host Topology (Command Line Option -tp) Host Configuration Command ummary a (View or Toggle Beacon tatus) b (ave or Update the Flash BIO or Fcode) c (how Parameter ettings) d (Update Device Driver) dm (Display Diagnostics Monitoring Info) e (Boot Device View elect Disable) ei (List ANsurfer FC HBA CLI Error Codes) f (Input Parameter Options from a Text File) fcoe (Display and Configure FCoE Engine Parameters) fg (how Driver ettings) fs (Configure Driver ettings) g (Display ystem Information) N H Page xi

12 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters A XML Format 1 -gs (how HBA tatistics) h (Help) ha (et Delete HBA Alias) i (Display HBA General Information or VPD Information for One or All HBAs) kl (Loopback Test) DataPattern (DP) Dataize (D) TestCount (TC) TestIncrement (TI) OnError (OE) Run a Loopback Test kl (Run HBA Diagnostics Loopback Test) kr (Run Read/Write Buffer Test) Run a Read/Write Buffer Test Run HBA Diagnostics Read-write Buffer Test l (Display LUN Info) ls (Display Link tatus) m (View, Enable, or Disable LUNs) n (et elected HBA Parameter) o (Output to a File) p (Display Persistent Target Binding Info) pa (Define Port Alias) q (View or et Target Link peed) r (Update HBA Parameters) s (ilent Mode) t (Display Target Information) tb (Target Beacon On/Off) tp (Display Host Topology) v (Display Version) vp (Virtual Port) x (Output in XML Format 1) x2 (Output in XML Format 2) z (Display All HBA information for One or All HBAs) Output Parts A-1 Main Tag A-1 Utility Header A-1 tatus Message A-2 Page xii N H

13 A ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Reboot Message A-2 Error Message A-2 XML Format 1 Tags for Each Option A-2 Display ystem Information (Command Line Option -g) A-3 Display Adapter ettings (Command Line Option -c) A-4 Display HBA Information (Command Line Option -i) A-5 Display Device List (Command Line Option -t) A-7 Display LUN List (Command Line Option -l) A-7 Target Persistent Binding (Command Line Option -p) A-8 elective LUNs (Command Line Option -m) A-8 Boot Device (Command Line Option -e) A-9 Diagnostics Results Loopback Test (Command Line Option -kl)... A-9 Diagnostics Results Read/Write Buffer Test (Command Line Option -kr) A-10 View Driver ettings (Command Line Option -fg) A-10 Display All Information for One or All HBAs (Command Line Option -z) A-11 Link tatistics (Command Line Option -ls) A-14 HBA tatistics (Command Line Option -gs) A-14 HBA Alias (Command Line Option -ha) A-15 HBA Port Alias (Command Line Option -pa) A-15 HBA Transceiver Details (Command Line Option -dm) A-16 Host Topology (Command Line Option -tp) A-20 Display FCoE Information A-22 Display FCoE Parameters A-23 Display FCoE Link Events A-23 Display FCoE DCX A-25 Display FCoE Network Interface tatistics A-26 B XML Format 2 Output Parts B-1 Main Tag B-1 Utility Header B-2 tatus Message B-2 Reboot Message B-2 Error Message B-2 XML Format 2 Tags for Each Option B-2 Display ystem Information (Command Line Option -g) B-4 Display Adapter ettings (Command Line Option -c) B-4 Display HBA Information (Command Line Option -I) B-5 Display Device List (Command Line Option -t) B-7 N H Page xiii

14 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Display LUN List (Command Line Option -l) B-8 Target Persistent Binding (Command Line Option -p) B-9 elective LUNs (Command Line Option -m) B-9 Boot Device (Command Line Option -e) B-10 Diagnostics Results Loopback Test (Command Line Option -kl)... B-11 Diagnostics Results Read/Write Buffer Test (Command Line Option -kr) B-12 View Driver ettings (Command Line Option -fg) B-12 Display All Information for One or All HBAs (Command Line Option -z) B-13 Link tatistics (Command Line Option -ls) B-16 HBA tatistics (Command Line Option -gs) B-17 HBA Alias (Command Line Option -ha) B-18 HBA Port Alias (Command Line Option -pa) B-18 HBA Transceiver Details (Command Line Option -dm) B-20 Host Topology (Command Line Option -tp) B-25 Display FCoE Information B-26 Display FCoE Parameters B-27 Display FCoE Link Events B-27 Display FCoE DCX B-29 Display FCoE Network Interface tatistics B-30 C D E Interactive Exit Codes Non-interactive Error Codes Help Commands Glossary Index Page xiv N H

15 A ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters List of Figures Figure Page 3-1 electing HBA Model (Example) Preparing to Install Dialog Box Welcome Dialog Box Choose Destination Location Dialog Box Ready to Install the Program Dialog Box etup tatus Dialog Box Installhield Wizard Complete DIalog Box List of Tables Table Page 2-1 Non-interactive Mode Options Windows Command Line Installation Parameters HBA Parameters ettings (NVRAM) Target/LUN Information Target Link peed ettings Driver ettings Template upported Parameter ettings for QLA246x/QLE246x and QLE256x HBAs Template upported Parameter ettings for QLA23xx HBAs (IP2312) Template upported Parameter ettings for QLA23xx HBAs (IP2300/2310) Template upported Parameter ettings for QLA23xx HBAs (IP2322) HBA Diagnostics Configuration ettings HBA Port tatistics Options tatistics/link tatus Options Options hown by -z Command Variables FCoE Engine Parameters Driver ettings Parameters HBA tatistics Parameters Data Pattern Values OnError Values Driver Versions Not Requiring a Loopback Connector Diagnostics Parameters Data Pattern (DP) Test Patterns Link tatus Parameters HBA Parameters A-1 Options Displayed by -z A-11 B-1 Options Displayed by -z B-13 C-1 Exit Code Descriptions: Interactive Mode C-1 D-1 Error Code Descriptions: Non-interactive Mode D-1 E-1 Help Commands E-1 N H Page xv

16 ANsurfer FC HBA CLI User s Guide Command Line Interface for QLogic FC and FCoE Adapters Page xvi N H

17 1 Introduction The ANsurfer FC HBA CLI tool provides a command line interface (CLI) that lets you easily install, configure, and deploy QLogic Fibre Channel (FC) host bus adapters (HBAs), as well as QLogic Fibre Channel over Ethernet (FCoE) converged network adapters (CNAs). It also provides robust diagnostic and troubleshooting capabilities and useful statistical information to optimize AN performance. This tool only configures HBAs on the local machine (where ANsurfer FC HBA CLI is installed.) ANsurfer FC HBA CLI is a simplified, condensed version of the ANsurfer FC HBA Manager graphical user interface (GUI), which manages both local and remote hosts. ANsurfer FC HBA CLI can be operated in two modes: Interactive mode (menu-driven interface). This mode requires user intervention. Non-interactive mode (command line interface). Use this mode for scripting or when you want to do a single operation. NOTE: This guide uses interchangeably the terms HBA, CNA, and adapter. This introductory chapter covers the following: Intended Audience on page 1-1 How this Guide is Organized on page 1-2 upported QLogic HBAs on page 1-4 upported Operating ystems on page 1-4 ystem Requirements on page 1-5 License Agreements on page 1-8 Technical upport on page 1-8 Intended Audience This guide is intended for end users responsible for administration of QLogic FC HBAs. N H 1-1

18 1 Introduction How this Guide is Organized How this Guide is Organized The ANsurfer FC HBA CLI User s Guide is organized into the following chapters and appendices: 1 Introduction: This chapter provides a general overview of the product, lists the supported QLogic HBAs and operating systems, lists the system hardware and software requirements, and provides contact information for technical support. 2 Getting tarted: This chapter describes the two modes used in ANsurfer FC HBA CLI: interactive and non-interactive. It also explains some special terms used in this guide. 3 Installing and Uninstalling ANsurfer FC HBA CLI: This chapter provides step-by-step instructions for installing and uninstalling ANsurfer FC HBA CLI on Windows, Linux, olaris, and Macintosh. 4 Interactive Commands: This chapter provides detailed explanations and examples of the command line options used in interactive mode. 5 Non-interactive Commands: This chapter provides detailed explanations and examples of the command line options used in non-interactive mode. A XML Format 1: This appendix provides explanations and examples of XML files created with the -x1 command line option. B XML Format 2: This appendix provides explanations and examples of XML files created with the -x2 command line option. C Interactive Exit Codes: This appendix lists the exit codes that can occur while running ANsurfer FC HBA CLI in interactive mode. For each exit code number, it provides the name and description. D Non-interactive Error Codes: This appendix lists the error codes that can occur while running ANsurfer FC HBA CLI in interactive mode. For each error code number, it provides the name and description. E Help Commands: This appendix provides an alphabetical list of the command line actions, arguments, and functions of the help commands. Following the appendices are a glossary of terms used and an index that will help you quickly find the information you need. Typographic Conventions This guide uses the following typographic conventions: Text in bold font indicates a menu or menu item. For example: From the General Information Menu, type the number for Host Topology. 1-2 N H

19 A 1 Introduction How this Guide is Organized Text in a sans serif font (Courier New) indicates CLI window text output. For example: The HBA already has the device selected as boot device. Text in a bold sans serif font (Courier New) indicates user input (what you type). For example: # scli -z Text in ALL CAPITAL and sans serif font indicates the name of a key that you press on the keyboard. For example: Type the number for Host Information and then press ENTER. Italicized text indicates either a document reference, glossary term, or emphasis. For example: Attached Port means a QLogic HBA... For a complete list, see the QLogic AN Interoperability Guide. Italicized text within angle brackets indicates user-defined variables. For example: # scli -k (<HBA Instance> <HBA WWPN>) Text shown in blue indicates a cross-reference hyperlink to a Web site or to another section of this guide. Click the hyperlink to jump to that site or section. For example: Visit the QLogic support Web site at support.qlogic.com for the latest firmware and product updates. For information on the Virtual Menu, see Virtual Menu for HBA Instance on page In 4 Interactive Commands, a breadcrumbs line follows most command headings to show you how to access that option; that is, it shows the hierarchical path from the top level to the command under discussion. For example, to reach the ave to Text File options from the main ANsurfer FC HBA CLI menu, you would select option 1 to open the General Information menu, 2 to open the Host Topology menu, and 2 again to see the ave to Text File options. The following shows a breadcrumbs example: 1: General Information 2: Host Topology 2: ave to Text File Related Materials For additional information, refer to the ANsurfer FC HBA CLI ReadMe file and release notes. N H 1-3

20 1 Introduction upported QLogic HBAs upported QLogic HBAs ANsurfer FC HBA CLI is supported for the following QLogic HBAs: QLA2xx QLA234x QLE2xx QLA246x QLE246x QLE256x QLE8042 Not all ANsurfer FC HBA CLI features are available on every supported HBA. NOTE: If ANsurfer FC HBA CLI detects an unsupported HBA, the following message appears, where X is the adapter instance number and YYYYYYY is the adapter model: upported Operating ystems ANsurfer FC HBA CLI is supported on the following operating systems: Microsoft Windows : Windows 2000, 32-bit, Intel x86 Intel 64, AMD64 Windows erver 2003, 32-bit Intel x86, Intel 64, AMD64 Windows erver 2008, 32-bit Intel x86, Intel 64, AMD64 Windows XP Professional, 32-bit Intel x86, Intel 64, AMD64 Windows XP Professional, x64-bit Intel 64, AMD64 Windows Vista, 32-bit Intel x86 Windows Vista x64 Linux : Unsupported HBA (Instance X YYYYYYY) If ANsurfer FC HBA CLI detects an HBA for which no information is known, the following message appears, where X is the adapter instance number, 0xYYYY is the subsystem vendor ID, and 0xZZZZ is subsystem device ID of the HBA: Unknown HBA type (Instance X VID=0xYYYY DID=0xZZZZ)! Red Hat RHEL A/E bit, 64-bit Intel IA64, Intel 64, AMD64 Red Hat RHEL A/E bit, 64-bit Intel IA64, Intel 64, AMD64 Red Hat RHEL A/E bit, 64-bit Intel IA64, Intel 64, AMD64 Red Hat RHEL A/E bit, 64-bit Intel x86, Intel 64, AMD N H

21 A 1 Introduction ystem Requirements Novell LE bit, 64-bit Intel IA64, Intel 64, AMD64 Novell LE 9 32-bit, 64-bit Intel IA64, Intel 64, AMD64 Novell LE 8 32-bit, 64-bit Intel x86, AMD64 NOTE: RHEL 3.0 and LE 8 do not support 8Gb HBAs. olaris : olaris 9, 10 x86 32-bit, 64-bit Intel x86, Intel 64, AMD64 olaris 2.6, 7, 8, 9, and 10 PARC 32-bit, 64-bit PARC Apple Macintosh : Mac O X (Panther/Tiger), 32-bit, 64-bit PowerPC/Intel NetWare : NetWare bit Intel x86, Intel 64, AMD64 VMware EX: EX bit, Intel 64, AMD64 NOTE: VMware does not support 8Gb HBAs at the time of publication of this guide. NOTE: Throughout this guide, the terms Windows, Linux, olaris, and Macintosh refer to all the respective supported operating systems unless otherwise noted. For specific service packs (Ps) and O updates, refer to the descriptions where this software version is posted on the QLogic Web site: ystem Requirements The system requirements for ANsurfer FC HBA CLI are described in the following sections: Hardware Requirements on page 1-6 oftware Requirements on page 1-6 N H 1-5

22 1 Introduction ystem Requirements Hardware Requirements The minimum hardware requirements are as follows: QLogic HBAs (see upported QLogic HBAs on page 1-4). ingle- or multiprocessor server or workstation: Pentium III with 450 MHz or greater for Windows 2000, Windows erver 2003, Windows XP Professional, Linux, and olaris. Windows Vista and Windows erver 2008 Use the minimum requirements from Microsoft. Power Mac G5 1.8 MHz or greater with 512 MB of memory. FC devices, such as disks and RAID subsystems. QLogic FC HBAs. ANsurfer FC HBA CLI supports most FC devices. For a complete list of devices that support failover, see the QLogic AN Interoperability Guide, which you can download from the QLogic Web site, NOTE: Tape devices are shown as part of the configuration, but are not fully supported by ANsurfer FC HBA CLI. Only persistent binding and LUN masking are available. 256 MB physical RAM are required to run ANsurfer FC HBA CLI; running with less memory can cause disk swapping ( paging or paging out ), which severely affects performance. Video card capable of 256 colors and a screen resolution of 800x600 pixels. About 7 MB of disk space. oftware Requirements Unsupported Features The minimum software requirements are as follows: QLogic drivers for your O platform. Administrative privileges to perform management functions. One of the operating systems listed in upported Operating ystems on page 1-4. Depending on your system, not all ANsurfer FC HBA features are available. 1-6 N H

23 A 1 Introduction ystem Requirements Features Not Available When Running Windows Driver with NPIV Enabled When running the driver with NPIV enabled on Windows, the following features are not available with virtual port: HBA parameters settings HBA parameters restore default Flash update from file Flash save to file HBA parameters update from file HBA parameters save to file HBA parameters update from templates Target link speed Boot device settings Driver settings HBA beacon Target/LUN list Features Not Available When Running ioctl Module Driver When running the input/output control (ioctl) module driver on a Linux O, the following features are not available: Persistent binding elective LUN HBA port statistics Driver settings Host topology Features Not Available When Running ysfs Inbox Driver When running the ysfs Inbox driver on a Linux O, the following features are not available: Persistent binding elective LUN HBA port statistics Driver settings Host topology Link status Loopback test Features Not Available When Running VMware Driver When running the VMware driver on a Linux O, the following features are not available with virtual ports: HBA parameters settings HBA parameters restore default Flash update from file N H 1-7

24 1 Introduction License Agreements Flash save to file HBA parameters update from file HBA parameters save to file HBA parameters update from templates License Agreements Refer to the QLogic oftware End User License Agreement for a complete listing of all license agreements affecting this product. Technical upport Availability Customers should contact their authorized maintenance provider for technical support of their QLogic switch products. QLogic-direct customers may contact QLogic Technical upport; others will be redirected to their authorized maintenance provider. Visit the QLogic support Web site listed in Contact Information for the latest firmware and software updates. QLogic Technical upport for products under warranty is available during local standard working hours excluding QLogic Observed Holidays. Training QLogic offers certification training for the technical professional for both the ANblade HBAs and the ANbox switches. From the training link at you may choose Electronic-Based Training or schedule an intensive hands-on Certification course. Technical Certification courses include installation, maintenance and troubleshooting QLogic AN products. Upon demonstrating knowledge using live equipment, QLogic awards a certificate identifying the student as a Certified Professional. The training professionals at QLogic may be reached by at tech.training@qlogic.com. 1-8 N H

25 A 1 Introduction Technical upport Contact Information Please feel free to contact your QLogic approved reseller or QLogic Technical upport at any phase of integration for assistance. QLogic Technical upport can be reached by the following methods: Web: North America Contact Information support@qlogic.com Phone: (952) upport contact information for other regions of the world is available at the QLogic Web site: The QLogic knowledge database contains troubleshooting information for the QLogic HBAs. Access the data base from the QLogic Web site, Click the upport tab, and then use the search engine at the top of the page to look for specific troubleshooting information. N H 1-9

26 1 Introduction Technical upport Notes 1-10 N H

27 2 Getting tarted This chapter provides the following sections to help you get started using ANsurfer FC HBA CLI: tarting Interactive Mode on page 2-1 tarting Non-interactive Mode on page 2-3 Terminology on page 2-7 ANsurfer FC HBA CLI Modes ANsurfer FC HBA CLI operates in two modes: Interactive (menu-driven). The CLI starts and prompts for user input. Based on the input, the CLI executes the specified commands until terminated by the user. Use this mode to do multiple operations. 4 Interactive Commands covers this interface. Non-interactive (command line). The CLI starts, executes the functions defined by the list of parameters provided, and then terminates. Use this mode to run ANsurfer FC HBA CLI from a script file or when you want to do a single operation. 5 Non-interactive Commands covers this interface. ANsurfer FC HBA CLI is not case sensitive in either mode. However, file names in some operating systems are case sensitive; in this case, ANsurfer FC HBA CLI is case sensitive for that specific file. tarting Interactive Mode To start ANsurfer FC HBA CLI in interactive mode, use one of these methods: For Windows, click the ANsurfer FC CLI icon on the desktop. For Linux or olaris, open a command window and type one of the following: scli INT scli NOTE: When starting ANsurfer FC HBA CLI from a olaris console serial port connection, the CLI may take a long time to come up. To resolve this issue, specify the INT flag, as shown in the preceding bullet. N H 2-1

28 2 Getting tarted tarting Interactive Mode For Mac O X, follow these steps: 1. Double-click the ANsurfer FC HBA CLI (CLI) icon. 2. A terminal window opens. CLI (interactive mode) scans the host for QLogic HBAs and AN storage. 3. Run CLI commands as required. 4. When finished, return to the main menu, and type the indicated number to exit ANsurfer FC HBA CLI. 5. Close the terminal window. The Main Menu appears as shown in the following: ANsurfer FC HBA CLI v1.x.x Build xx Main Menu 1: General Information 2: HBA Information 3: HBA Parameters 4: Target/LUN List 5: Target Link peed or 5: iidma ettings 6: Target Persistent Bindings 7: elective LUNs 8: Boot Device 9: Driver ettings 10: Utilities 11: Beacon 12: Diagnostics 13: tatistics 14: Help or 14: Virtual (if available) 15: Exit or 15: Help or 16: Exit NOTE: The Virtual menu is available only on Windows systems running with a driver that supports NPIV (N_Port ID Virtualization). Depending on which menu you select, may prompt you for more input. For example, if you select HBA Parameters, ANsurfer FC HBA CLI prompts you for the port number that corresponds to the HBA model you want to view. 2-2 PRELIMINARY N H

29 A 2 Getting tarted tarting Non-interactive Mode NOTE: The Driver Update option under Utilities (option 10) is only available on Windows. In olaris PARC, the option to ave/update BIO is ave/update FCode. tarting Non-interactive Mode To start ANsurfer FC HBA CLI in non-interactive mode, type the following in a command window: scli <Parameters> ANsurfer FC HBA CLI executes the command options, then terminates. To list all of the available command line parameters and the ANsurfer FC HBA CLI version, type one of the following: scli -h scli -? In olaris PARC, include double quotes around the view option (?) if the system is running with a csh or tsch shell. For example: # scli -e 0 "?" For world wide node name (WWNN), world wide port name (WWPN), and port ID parameter inputs, ANsurfer FC HBA CLI accepts the notation with and without the dash ( ). Hexadecimal values can be uppercase or lowercase. The following input formats are valid for the WWNN and WWPN: E0-8B C E08B0183C4 The following inputs are valid for the port ID: 68-5C-AB 685CAB All command line options must be preceded by the dash ( ) or forward slash (/) notation. Most options have a corresponding menu selection in interactive mode. The valid command line options are listed in Table 2-1. N H 2-3

30 2 Getting tarted tarting Non-interactive Mode. Table 2-1. Non-interactive Mode Options CLI Option Interactive Menu (Windows) Interactive Menu (Red Hat/UE Linux, olaris PARC) Interactive Menu (Macintosh) Description ee User Guide ection -a Flash HBA beacon -a (View or Toggle Beacon tatus) on page 5-6 -b ave/update BIO/FCode a b -b (ave or Update the Flash BIO or Fcode) on page 5-7 -c how HBA settings -c (how Parameter ettings) on page 5-8 -d Update driver -d (Update Device Driver) on page 5-8 -dm Transceiver details -dm (Display Diagnostics Monitoring Info) on page 5-9 -e Boot device settings -e (Boot Device View elect Disable) on page 5-9 -f Input from a file -f (Input Parameter Options from a Text File) on page fg View driver settings -fg (how Driver ettings) on page fs Driver settings -fs (Configure Driver ettings) on page HBA utilities -g how system information -g (Display ystem Information) on page PRELIMINARY N H

31 A 2 Getting tarted tarting Non-interactive Mode Table 2-1. Non-interactive Mode Options (Continued) CLI Option Interactive Menu (Windows) Interactive Menu (Red Hat/UE Linux, olaris PARC) Interactive Menu (Macintosh) Description ee User Guide ection -gs HBA statistics -gs (how HBA tatistics) on page h -? how usage how usage -h (Help) on page ha HBA alias -ha (et Delete HBA Alias) on page i how HBA information -i (Display HBA General Information or VPD Information for One or All HBAs) on page kl Loopback test -kl (Loopback Test) on page kr Read/write buffer test -kr (Run Read/Write Buffer Test) on page l how LUN list -l (Display LUN Info) on page ls how Link status -ls (Display Link tatus) on page m elective LUNs -m (View, Enable, or Disable LUNs) on page n Configure HBA settings -n (et elected HBA Parameter) on page 5-34 N H 2-5

32 2 Getting tarted tarting Non-interactive Mode Table 2-1. Non-interactive Mode Options (Continued) CLI Option Interactive Menu (Windows) Interactive Menu (Red Hat/UE Linux, olaris PARC) Interactive Menu (Macintosh) Description ee User Guide ection -o Output to a file -o (Output to a File) on page p Target persistent binding -p (Display Persistent Target Binding Info) on page pa HBA port alias -pa (Define Port Alias) on page q Target link speed -q (View or et Target Link peed) on page r ave/update NVRAM Refresh 15 (16) 15 (16) 15 (16) Quit -s ilent mode -s (ilent Mode) on page t how device list -t (Display Target Information) on page tb Flash target beacon -tb (Target Beacon On/Off) on page tp how host topology -tp (Display Host Topology) on page v how version -v (Display Version) on page x Output in XML format -x (Output in XML Format 1) on page PRELIMINARY N H

33 A 2 Getting tarted Terminology Table 2-1. Non-interactive Mode Options (Continued) CLI Option Interactive Menu (Windows) Interactive Menu (Red Hat/UE Linux, olaris PARC) Interactive Menu (Macintosh) Description ee User Guide ection -z how all information for one or all HBAs Table Notes -z (Display All HBA information for One or All HBAs) on page 5-44 a b Windows, Linux, olaris x86 olaris PARC Options that have a corresponding menu selection cannot be combined. That is, only one option is allowed in a single command. If multiple options are specified in a command, only the first one is processed. These options, however, can be combined with one or more options that do not have a corresponding menu selection, with the exception of -F. For all command line options, ANsurfer FC HBA CLI shows the following when there are errors in the command line input: Error <error message> ANsurfer FC HBA CLI v1.x.x Build xx Copyright QLogic Corp. All rights reserved. Command Line QLogic FC Host Bus Adapters description of command entered Usage: <current command use usage> Terminology ome of the terms used in this guide are similar and some have changed slightly as technology changes. The following definitions apply: HBA Port HBA Port refers to the actual physical port on an HBA. For example, a QLA2462 has two ports called HBA port 1 and HBA port 2. N H 2-7

34 2 Getting tarted Terminology HBA Instance, HBA Instance number, or HBA Port Instance. When you install HBA in a system with other HBAs, each HBA port gets assigned a number by the driver or API so it knows which HBA to communicate with. This assigned number might be called HBA Instance, HBA instance number, or HBA Port Instance. HBA Alias. When an alias is assigned to a physical HBA, no matter how many ports that HBA has, the HBA Alias refers to the HBA, not one of its ports. Port Alias. You can also assign an alias to an individual port on an HBA. This Port Alias refers to only that port and none other. Thus, an HBA can only have one HBA Alias, but each port on that HBA must, have a unique Port Alias. 2-8 PRELIMINARY N H

35 3 Installing and Uninstalling ANsurfer FC HBA CLI This chapter provides procedures for downloading and installing ANsurfer FC HBA CLI, as well as how to remove the product. Refer to the following sections: Downloading the Installation Package on page 3-1 Installing ANsurfer FC HBA CLI on page 3-2 Uninstalling ANsurfer FC HBA CLI on page 3-14 Prerequisites Before you run ANsurfer FC HBA CLI, ensure that the following requirements are met: The HBAs must be installed. The HBA drivers must be installed. NOTE: ome ANsurfer FC HBA CLI features are not available when: You have a olaris system that is running with the driver distributed with the O installation CDs (QLC driver). You have a Linux system that is running with the ioctl or sysfs (inbox) driver. You have a Linux system that is running with a VMware driver. Downloading the Installation Package Follow these steps to download the ANsurfer FC HBA CLI installation package from the QLogic Web site. To download the installation package: 1. From the QLogic home page ( click the Downloads tab. 2. On the Driver Downloads / Manuals page, select your HBA model and then click Go! (Figure 3-1 shows an example.) N H 3-1

36 3 Installing and Uninstalling ANsurfer FC HBA CLI Installing ANsurfer FC HBA CLI Figure 3-1 electing HBA Model (Example) The resources page for the selected model appears. 3. Under Management Tools, click ANsurfer CLI... The End User oftware License Agreement page appears. 4. croll to the bottom and click Agree. 5. On the File Download dialog box, click ave. elect a directory on your system and download the file. Installing ANsurfer FC HBA CLI Follow the installation instructions in the section that corresponds to your operating system (O): Windows Installation on page 3-2 Linux Installation on page 3-9 olaris Installation on page 3-9 Macintosh Installation on page 3-12 Windows Installation To install ANsurfer FC HBA CL on Windows, follow either the GUI or command line installation steps: tandard (GUI) Installation on page 3-2 Command Line Installation on page 3-7 tandard (GUI) Installation Follow these steps to install ANsurfer FC HBA CLI on a Windows operating system using the standard (GUI) method. 3-2 PRELIMINARY N H

37 A 3 Installing and Uninstalling ANsurfer FC HBA CLI Installing ANsurfer FC HBA CLI To install ANsurfer FC HBA CLI on Windows (GUI): 1. Locate and double-click the installer package. The Preparing to Install dialog box appears, as shown in Figure 3-2. The status bar indicates that the installation package is loading. Figure 3-2 Preparing to Install Dialog Box After the install package is loaded, the Welcome dialog box appears as shown in Figure 3-3. N H 3-3

38 3 Installing and Uninstalling ANsurfer FC HBA CLI Installing ANsurfer FC HBA CLI Figure 3-3 Welcome Dialog Box 2. Read the information, and then click Next. The Choose Destination Location dialog box appears as shown in Figure 3-4. Figure 3-4 Choose Destination Location Dialog Box 3-4 PRELIMINARY N H

39 A 3 Installing and Uninstalling ANsurfer FC HBA CLI Installing ANsurfer FC HBA CLI 3. In the Choose Destination Location dialog box, do one of the following: To select the destination location in the dialog box, click Next (recommended). The default location for a Windows system is: Program Files\QLogic Corporation\ANsurferCLI To select a different location: a. Click Browse. b. elect an installation location. c. The Choose Destination Location dialog box reappears. Click Next. The Ready to Install the Program dialog box appears as shown in Figure 3-5. Figure 3-5 Ready to Install the Program Dialog Box 4. Read the information, and then click Install. The etup tatus dialog box appears as shown in Figure 3-6. N H 3-5

40 3 Installing and Uninstalling ANsurfer FC HBA CLI Installing ANsurfer FC HBA CLI Figure 3-6 etup tatus Dialog Box If you want to stop the installation, click Cancel. The Installhield Wizard Complete dialog box appears as shown in Figure 3-7. Figure 3-7 Installhield Wizard Complete DIalog Box 3-6 PRELIMINARY N H

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents SANsurfer Fibre Channel Command Line Interface (CLI) QLogic Corporation All rights reserved Table of Contents 1 Package Contents 2 Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3 OS

More information

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents SANsurfer FC/CNA HBA Command Line Interface (CLI) QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3. OS

More information

SANsurfer FC HBA Manager User s Guide

SANsurfer FC HBA Manager User s Guide ANsurfer FC HBA Manager User s Guide Management Tool for QLogic Fibre Channel Host Bus Adapters N0054651-00 A ANsurfer FC HBA Manager User s Guide Management Tool for QLogic Fibre Channel Host Bus Adapters

More information

SANsurfer FC HBA Manager. Table of Contents

SANsurfer FC HBA Manager. Table of Contents SANsurfer FC HBA Manager This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements

More information

SANsurfer iscsi HBA Application User s Guide

SANsurfer iscsi HBA Application User s Guide Q Simplify SANsurfer iscsi HBA Application User s Guide Management Application for SANsurfer iscsi Host Bus Adapters IS0054602-00 A Page i SANsurfer iscsi HBA Application User s Guide Management Application

More information

SANsurfer FC HBA Manager. Table of Contents

SANsurfer FC HBA Manager. Table of Contents SANsurfer FC HBA Manager This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements

More information

SANsurfer FC/FCoE HBA Manager. Table of Contents

SANsurfer FC/FCoE HBA Manager. Table of Contents SANsurfer FC/FCoE HBA Manager QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3. OS Support 4. Supported

More information

SANsurfer iscsi Host Bus Adapter CLI. Table of Contents

SANsurfer iscsi Host Bus Adapter CLI. Table of Contents SANsurfer iscsi Host Bus Adapter CLI QLogic Corporation All rights reserved Table of Contents 1 Package Contents 2 Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3 OS Support 4 Supported

More information

SANsurfer iscsi HBA CLI. Table of Contents

SANsurfer iscsi HBA CLI. Table of Contents SANsurfer iscsi HBA CLI QLogic Corporation All rights reserved Table of Contents 1 Package Contents 2 Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3 OS Support 4 Supported Features

More information

QConvergeConsole. Table of Contents

QConvergeConsole. Table of Contents QConvergeConsole QLogic Corporation All rights reserved Table of Contents 1 Package Contents 2 Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3 OS Support 4 Supported Features 5 Using

More information

SANsurfer Converged Network Adapter Networking CLI. Table of Contents

SANsurfer Converged Network Adapter Networking CLI. Table of Contents SANsurfer Converged Network Adapter Networking CLI QLogic Corporation All rights reserved Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3. OS

More information

FC HBA STOR Miniport Driver for Windows. Table of Contents

FC HBA STOR Miniport Driver for Windows. Table of Contents FC HBA STOR Miniport Driver for Windows This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. 1. Package Contents 2. OS Support 3. Supported Features 4. Using

More information

Flash Image for 3200 and 8200 Series Adapters. Table of Contents

Flash Image for 3200 and 8200 Series Adapters. Table of Contents Flash Image for 3200 and 8200 Series Adapters QLogic Corporation All rights reserved Table of Contents 1 Package Contents 1.1 Update the Flash Image 2 FCoE BIOS (8200 Series only) 2.1 Supported Features

More information

Software Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus

Software Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus Software Installation Guide for the QLA22xx Board Family Fibre Channel Host Adapter Boards for the PCI Bus FC0153302-00 F July 20, 2001 QLogic Corporation Information furnished in this manual is believed

More information

SANsurfer Fibre Channel (FC) HBA Manager. Table of Contents

SANsurfer Fibre Channel (FC) HBA Manager. Table of Contents SANsurfer Fibre Channel (FC) HBA Manager This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. OS Support 2. Supported Features 3. Application

More information

QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4. Table of Contents

QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4. Table of Contents QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4 Version: 7.07.05 OS Support : HBA Support: Red Hat RHEL 3 AS - Update 7 and Update 6 (IA32, EM64T, AMD64, IA64) Novell SLES

More information

BIOS for QLA4010 iscsi HBAs. Table of Contents

BIOS for QLA4010 iscsi HBAs. Table of Contents BIOS for QLA4010 iscsi HBAs This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. OS Support 2. Supported Features 3. Creating the Driver

More information

QConvergeConsole CLI Readme. QLogic Corporation All rights reserved

QConvergeConsole CLI Readme. QLogic Corporation All rights reserved QConvergeConsole CLI Readme QLogic Corporation All rights reserved Note: Please check the driverdownloads.qlogic.com website for the most up-to-date readme information for this application Table of Contents

More information

Data Migration Service for isr6200

Data Migration Service for isr6200 Data Migration Service for isr6200 User s Guide ISR654608-00 D Data Migration Service for isr6200 User s Guide Information furnished in this manual is believed to be accurate and reliable. However, QLogic

More information

Fibre Channel Adapter STOR Miniport Driver for Windows. Table of Contents

Fibre Channel Adapter STOR Miniport Driver for Windows. Table of Contents Fibre Channel Adapter STOR Miniport Driver for Windows QLogic Corporation All rights reserved Table of Contents 1. Package Contents 2. OS Support 3. Supported Features 4. Using the Driver 4.1 Creating

More information

[ Quick Start Guide ]

[ Quick Start Guide ] [ Quick Start Guide ] QUICK START GUIDE FIBRE CHANNEL SWITCH INSTALLATION z SANbox 5800V Series for Windows Operating Systems Purchasers of OEM products should consult with the OEM for support. Please

More information

Multi-boot Image for Qxx8xxx Converged Network Adapters. Table of Contents

Multi-boot Image for Qxx8xxx Converged Network Adapters. Table of Contents Multi-boot Image for Qxx8xxx Converged Network Adapters QLogic Corporation All rights reserved Table of Contents 1. Version 2. 10Gb BIOS 2.1 Changes 2.2 Bug Fixes 2.3 Known Issues 2.4 Additional Information

More information

[ Quick Start Guide ]

[ Quick Start Guide ] [ Quick Start Guide ] QUICK START GUIDE INTELLIGENT STORAGE ROUTER INSTALLATION z isr6250 Purchasers of OEM products should consult with the OEM for support. Please feel free to contact your QLogic approved

More information

[ User s Guide] QLA 200 Family. User s Guide FIBRE CHANNEL HBA INSTALLATION

[ User s Guide] QLA 200 Family. User s Guide FIBRE CHANNEL HBA INSTALLATION [ User s Guide] User s Guide FIBRE CHANNEL HBA INSTALLATION P QLA 200 Family Covers the following operating systems: Windows 2000 Windows Server 2003 Red Hat Linux SuSE Linux NetWare Technical Support

More information

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x QLogic Corporation. All rights reserved. Table of Contents 1. Version 2. Changes 3. Bug Fixes 4. Known Issues 5. Additional Information 6. History

More information

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05 EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006

More information

ExpressCluster X 2.0 for Linux

ExpressCluster X 2.0 for Linux ExpressCluster X 2.0 for Linux Installation and Configuration Guide 03/31/2009 3rd Edition Revision History Edition Revised Date Description First 2008/04/25 New manual Second 2008/10/15 This manual has

More information

ExpressCluster X 3.2 for Linux

ExpressCluster X 3.2 for Linux ExpressCluster X 3.2 for Linux Installation and Configuration Guide 5/23/2014 2nd Edition Revision History Edition Revised Date Description 1st 2/19/2014 New manual 2nd 5/23/2014 Corresponds to the internal

More information

FC HBA Driver for NetWare. Table of Contents

FC HBA Driver for NetWare. Table of Contents FC HBA Driver for NetWare This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. OS Support 3. Supported Features 4. Using

More information

Laser Beam Printer. Network Guide. IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference.

Laser Beam Printer. Network Guide. IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference. Laser Beam Printer Network Guide IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference. ENG Network Guide How This Manual Is Organized Chapter 1 Before

More information

The DataCore and Host servers

The DataCore and Host servers The DataCore and Host servers Qualified Hardware Components February 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. In general

More information

P/N REV A13. EMC Corporation Corporate Headquarters: Hopkinton, MA

P/N REV A13. EMC Corporation Corporate Headquarters: Hopkinton, MA EMC Host Connectivity with QLogic Fibre Channel and iscsi Host Bus Adapters (HBAs) and Fibre Channel over Ethernet Converged Network Adapters (CNAs) for the Linux Environment P/N 300-002-803 REV A13 EMC

More information

FC HBA Driver Installation Script for Linux. Table of Contents

FC HBA Driver Installation Script for Linux. Table of Contents FC HBA Driver Installation Script f Linux This software license applies only to QLogic customers. QLogic Cpation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 3. OS Suppt

More information

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at:

More information

User s Guide. Setting Up NPAR with QLogic Control Suite, QConvergeConsole, or Comprehensive Configuration Management

User s Guide. Setting Up NPAR with QLogic Control Suite, QConvergeConsole, or Comprehensive Configuration Management User s Guide Setting Up NPAR with QLogic Control Suite, QConvergeConsole, or Comprehensive Configuration Management 3400 and 8400 Series Adapters Windows Operating Systems BC0154502-00 B User s Guide Setting

More information

Emulex Drivers Version 10.6 for Windows. Quick Installation Manual

Emulex Drivers Version 10.6 for Windows. Quick Installation Manual Emulex Drivers Version 10.6 for Windows Quick Installation Manual Connect Monitor Manage 2 Copyright 2003-2015 Emulex. All rights reserved worldwide. No part of this document may be reproduced by any means

More information

Qualified Hardware Components

Qualified Hardware Components For DataCore and Host Servers October 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. The authority on real-time data Changes

More information

The DataCore and Host servers

The DataCore and Host servers The DataCore and Host servers Qualified Hardware Components May 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. In general DataCore

More information

Emulex and QLogic 8 Gb Fibre Channel Host Bus Adapters for IBM System x deliver robustness, ease of management, and high performance

Emulex and QLogic 8 Gb Fibre Channel Host Bus Adapters for IBM System x deliver robustness, ease of management, and high performance IBM United States Announcement 108-481, dated July 8, 2008 Emulex and QLogic 8 Gb Fibre Channel Host Bus Adapters for IBM System x deliver robustness, ease of management, and high performance Description...2

More information

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-7272 First edition: December 2007 Legal and notice information Copyright

More information

Windows SuperInstaller Readme. QLogic Corporation All rights reserved. Table of Contents

Windows SuperInstaller Readme. QLogic Corporation All rights reserved. Table of Contents Windows SuperInstaller Readme QLogic Corporation All rights reserved Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3. OS Support 4. Supported

More information

Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx

Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx IBM AnyPlace Kiosk 4838 Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx GA27-4371-01 IBM AnyPlace Kiosk 4838 Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx

More information

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

DSI Optimized Backup & Deduplication for VTL Installation & User Guide DSI Optimized Backup & Deduplication for VTL Installation & User Guide Restore Virtualized Appliance Version 4 Dynamic Solutions International, LLC 373 Inverness Parkway Suite 110 Englewood, CO 80112 Phone:

More information

Intel Solid State Drive Firmware Update Tool

Intel Solid State Drive Firmware Update Tool Intel Solid State Drive Firmware Update Tool Software Version 3.0.0 or later Document Number: 322570-011US Intel disclaims all express and implied warranties, including without limitation, the implied

More information

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. OS Support 3. Supported Features 4. Deploying the Driver 4.1

More information

ExpressCluster X 3.1 for Linux

ExpressCluster X 3.1 for Linux ExpressCluster X 3.1 for Linux Installation and Configuration Guide 10/11/2011 First Edition Revision History Edition Revised Date Description First 10/11/2011 New manual Copyright NEC Corporation 2011.

More information

Lenovo XClarity Provisioning Manager User Guide

Lenovo XClarity Provisioning Manager User Guide Lenovo XClarity Provisioning Manager User Guide Fifth Edition (October 2018) Copyright Lenovo 2017, 2018. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services

More information

[ Quick Start Guide ]

[ Quick Start Guide ] [ Quick Start Guide ] QUICK START GUIDE FIBRE CHANNEL SWITCH INSTALLATION z Purchasers of OEM products should consult with the OEM for support. Please feel free to contact your QLogic-approved reseller

More information

Application Note EDC Firmware Update for QLogic 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter

Application Note EDC Firmware Update for QLogic 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter Application Note EDC Firmware Update for QLogic 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter 1 Introduction This document provides instructions for IBM technical personnel and system administrators

More information

Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents

Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents Converged Network Adapter NDIS Miniport Driver for Windows 1. Package Contents 2. OS Support 3. Supported Features 4. Using the Driver 4.1 Creating the Driver Disk 4.2 Installing the Driver 4.3 Removing

More information

[ Quick Start Guide ]

[ Quick Start Guide ] [ Quick Start Guide ] QUICK START GUIDE INTELLIGENT STORAGE ROUTER INSTALLATION z isr6200 Purchasers of OEM products should consult with the OEM for support. Please feel free to contact your QLogic approved

More information

Parallels Server 5 Bare Metal

Parallels Server 5 Bare Metal Parallels Server 5 Bare Metal Installation Guide Copyright 1999-2011 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels Holdings, Ltd. c/o Parallels International GMbH. Parallels

More information

SuperLumin Nemesis. Getting Started Guide. February 2011

SuperLumin Nemesis. Getting Started Guide. February 2011 SuperLumin Nemesis Getting Started Guide February 2011 SuperLumin Nemesis Legal Notices Information contained in this document is believed to be accurate and reliable. However, SuperLumin assumes no responsibility

More information

The HBAs tested in this report are the Brocade 825 and the Emulex LightPulse LPe12002 and LPe12000.

The HBAs tested in this report are the Brocade 825 and the Emulex LightPulse LPe12002 and LPe12000. HBA Product Evaluation Evaluation report prepared under contract with Corporation Introduction Due to increased interest in 8 Gb/s Fibre Channel host bus adapters, Corporation commissioned Demartek to

More information

Hitachi Storage Command Portal Installation and Configuration Guide

Hitachi Storage Command Portal Installation and Configuration Guide Hitachi Storage Command Portal Installation and Configuration Guide FASTFIND LINKS Document Organization Product Version Getting Help Table of Contents # MK-98HSCP002-04 Copyright 2010 Hitachi Data Systems

More information

HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system.

HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system. HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system. Martin Gingras Product Field Engineer, Canada mgingras@ca.ibm.com Acknowledgements Thank you to the many people who have contributed and reviewed

More information

Application Note EDC Firmware Update for QLogic 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter

Application Note EDC Firmware Update for QLogic 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter Application Note EDC Firmware Update for QLogic 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter 1 Introduction This document provides instructions for IBM technical personnel and system administrators

More information

Parallels Server 4.0 for Mac Bare Metal Edition

Parallels Server 4.0 for Mac Bare Metal Edition Parallels Server 4.0 for Mac Bare Metal Edition Installation Guide Copyright 1999-2010 Parallels Holdings, Ltd. Parallels Holdings, Ltd. c/o Parallels International GMbH. Parallels International GmbH Vordergasse

More information

Symantec pcanywhere 12.5 SP4 Release Notes

Symantec pcanywhere 12.5 SP4 Release Notes Symantec pcanywhere 12.5 SP4 Release Notes Symantec pcanywhere 12.5 SP4 Release Notes The software described in this book is furnished under a license agreement and may be used only in accordance with

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0 Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0 Revision 1.0 February 2000 Revision History Revision Revision History Date 1.0 Initial Release 02/10/00 Intel Corporation

More information

Installation Guide. QConvergeConsole GUI

Installation Guide. QConvergeConsole GUI Installation Guide QConvergeConsole GUI 2400, 2500, 2600, 2700 Series Fibre Channel Adapters 3200, 3400, 41000, 45000 Series Intelligent Ethernet Adapters 8100, 8200, 8300, 8400 Series Converged Network

More information

Qualified Hardware Components

Qualified Hardware Components DataCore and Host Servers November 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. Also see Minimum Hardware Requirements https://www.datacore.com/products/software-defined-storage/tech/prerequisites/

More information

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-0025 Third edition: July 2009 Legal and notice information Copyright

More information

Version Monitoring Agent User s Guide SC

Version Monitoring Agent User s Guide SC Tivoli IBM Tivoli Advanced Catalog Management for z/os Version 02.01.00 Monitoring Agent User s Guide SC23-7974-00 Tivoli IBM Tivoli Advanced Catalog Management for z/os Version 02.01.00 Monitoring Agent

More information

How to Configure NPIV in a Microsoft Hyper-V Environment

How to Configure NPIV in a Microsoft Hyper-V Environment How to Configure NPIV in a Microsoft Hyper-V Environment Designed for Windows System Administrators and Storage Administrators, this document provides guidelines for configuring Microsoft Hyper-V using

More information

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Dell EMC Engineering February 2018 A Dell EMC Technical White Paper Revisions Date August 2017

More information

IBM XIV Host Attachment Kit for HP-UX Version Release Notes

IBM XIV Host Attachment Kit for HP-UX Version Release Notes IBM XIV Host Attachment Kit for HP-UX Version 2.4.0 Release Notes First Edition (March 2015) This document edition applies to version 2.4.0 of the IBM XIV Host Attachment Kit for HP-UX software package.

More information

EXPRESSCLUSTER X 3.3 for Linux

EXPRESSCLUSTER X 3.3 for Linux EXPRESSCLUSTER X 3.3 for Linux Installation and Configuration Guide 04/10/2017 5th Edition Revision History Edition Revised Date Description 1st 02/09/2015 New manual. 2nd 06/30/2015 Corresponds to the

More information

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation ProLiant CL380 Software User Guide Fourth Edition (December 2000) Part Number 157839-004 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation COMPAQ and the Compaq logo, Compaq Insight Manager,

More information

10GbE Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents

10GbE Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents 10GbE Converged Network Adapter NDIS Miniport Driver for Windows QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. OS Support 3. Supported Features 4. Using the Driver 4.1

More information

EXPRESSCLUSTER X Integrated WebManager

EXPRESSCLUSTER X Integrated WebManager EXPRESSCLUSTER X Integrated WebManager Administrator s Guide 10/02/2017 12th Edition Revision History Edition Revised Date Description 1st 06/15/2009 New manual 2nd 09/30/2009 This manual has been updated

More information

Appendix A Fast!UTIL

Appendix A Fast!UTIL Appendix A Fast!UTIL This appendix is part of the QLogic Corporation manual Hardware Installation Guide for the QLA1xxx Boards (PC0056105-00 E). The QLogic disclaimer and copyright notices for this document

More information

Oracle Retail WebTrack Release Notes Release September 2007

Oracle Retail WebTrack Release Notes Release September 2007 Oracle Retail WebTrack Release Notes Release 12.0.2 September 2007 Oracle Retail WebTrack Release Notes, Release 12.0.2 Copyright 2007, Oracle. All rights reserved. Primary Author: Rich Olson The Programs

More information

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.0 This paper describes how to implement a Fibre Channel (FC) SAN

More information

Product Release Notes

Product Release Notes Product Release Notes ATTO Configuration Tool v4.14 - Windows 1. General Release Information The ATTO Configuration Tool helps you customize the settings of your ATTO storage Controller to maximize the

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

MegaRAID Device Driver Installation

MegaRAID Device Driver Installation USER S GUIDE MegaRAID Device Driver Installation February 2005 DB11-000018-02 This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used

More information

Emulex Drivers Version 10.2 for Windows

Emulex Drivers Version 10.2 for Windows Emulex Drivers Version 10.2 for Windows Quick Installation Manual Emulex Connects Servers, Storage and People 2 Copyright 2003-2014 Emulex. All rights reserved worldwide. No part of this document may be

More information

Parallels Transporter

Parallels Transporter Parallels Transporter User's Guide Copyright 1999-2011 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels Holdings, Ltd. c/o Parallels International GMbH. Parallels International

More information

QLogic iscsi Boot for HP FlexFabric Adapters User Guide

QLogic iscsi Boot for HP FlexFabric Adapters User Guide QLogic iscsi Boot for HP FlexFabric Adapters User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in

More information

IBM XIV Host Attachment Kit for HP-UX Version Release Notes

IBM XIV Host Attachment Kit for HP-UX Version Release Notes IBM XIV Host Attachment Kit for HP-UX Version 2.3.0 Release Notes First Edition (August 2014) This document edition applies to version 2.3.0 of the IBM XIV Host Attachment Kit for HP-UX software package.

More information

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: July 29, 2008 IBM System Storage DS3000 Interoperability Matrix - 2 - Table

More information

Fibre Channel Adapter and Converged Network Adapter Inbox Driver Update for Linux Kernel 2.6.x and 3.x. Readme. QLogic Corporation All rights reserved

Fibre Channel Adapter and Converged Network Adapter Inbox Driver Update for Linux Kernel 2.6.x and 3.x. Readme. QLogic Corporation All rights reserved Fibre Channel Adapter and Converged Network Adapter Inbox Driver Update for Linux Kernel 2.6.x and 3.x Readme QLogic Corporation All rights reserved Table of Contents 1. Package Contents 2. OS Support

More information

Lenovo XClarity Essentials UpdateXpress User Guide

Lenovo XClarity Essentials UpdateXpress User Guide Lenovo XClarity Essentials UpdateXpress User Guide Version 2.2.0 Note Before using this documentation and the products it supports, read the information in Appendix B Notices on page 19. This edition applies

More information

Parallels Transporter Agent

Parallels Transporter Agent Parallels Transporter Agent User's Guide Copyright 1999-2015 Parallels IP Holdings GmbH and its affiliates. All rights reserved. Parallels IP Holdings GmbH Vordergasse 59 8200 Schaffhausen Switzerland

More information

Hardware Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus

Hardware Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus Hardware Installation Guide for the QLA22xx Board Family Fibre Channel Host Adapter Boards for the PCI Bus FC0151103-00 E February 6, 2001 QLogic Corporation Information furnished in this manual is believed

More information

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Revision: 20090313 Item:

More information

LSI SAS i PCIe to 6Gb/s SAS HBA Running On Dell Systems Important Information

LSI SAS i PCIe to 6Gb/s SAS HBA Running On Dell Systems Important Information LSI SAS 9207-8i PCIe to 6Gb/s SAS HBA Running On Dell Systems Important Information CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters.

The Contents and Structure of this Manual. This document is composed of the following three chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ETERNUS SF Express V15.3/ Storage Cruiser V15.3/ AdvancedCopy Manager V15.3. Migration Guide

ETERNUS SF Express V15.3/ Storage Cruiser V15.3/ AdvancedCopy Manager V15.3. Migration Guide ETERNUS SF Express V15.3/ Storage Cruiser V15.3/ AdvancedCopy Manager V15.3 Migration Guide B1FW-5958-06ENZ0(00) June 2013 Preface Purpose This manual describes how to upgrade to this version from the

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: 8/28/2007 IBM System Storage DS3000 series Interoperability Matrix

More information

Network Management Utility

Network Management Utility 4343-7705-02 Network Management Utility Foreword Welcome Network Management Utility is utility software that provides central control over printers, copiers, and other devices on a network. With Network

More information

IBM Tivoli Federated Identity Manager Version Installation Guide GC

IBM Tivoli Federated Identity Manager Version Installation Guide GC IBM Tivoli Federated Identity Manager Version 6.2.2 Installation Guide GC27-2718-01 IBM Tivoli Federated Identity Manager Version 6.2.2 Installation Guide GC27-2718-01 Note Before using this information

More information

Windows Host Utilities Installation and Setup Guide

Windows Host Utilities Installation and Setup Guide IBM System Storage N series Windows Host Utilities 6.0.1 Installation and Setup Guide GC52-1295-06 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information,

More information

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Version 4.0 Configuring Hosts to Access VMware Datastores P/N 302-002-569 REV 01 Copyright 2016 EMC Corporation. All rights reserved.

More information

ExpressCluster X 1.0 for Linux

ExpressCluster X 1.0 for Linux ExpressCluster X 1.0 for Linux Installation and Configuration Guide 10/12/2007 Fifth Edition Revision History Edition Revised Date Description First 2006/09/08 New manual Second 2006/12/12 EXPRESSCLUSTER

More information

FUJITSU Storage ETERNUS SF Express V16.5 / Storage Cruiser V16.5 / AdvancedCopy Manager V16.5. Migration Guide

FUJITSU Storage ETERNUS SF Express V16.5 / Storage Cruiser V16.5 / AdvancedCopy Manager V16.5. Migration Guide FUJITSU Storage ETERNUS SF Express V16.5 / Storage Cruiser V16.5 / AdvancedCopy Manager V16.5 Migration Guide B1FW-6000-06ENZ0(01) June 2017 Preface Purpose This manual describes how to upgrade to this

More information

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode) Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode) Dell Networking Solutions Engineering July 2011 A Dell EMC Deployment and Configuration Guide Revisions Date Description

More information