[ User s Guide] QLA 200 Family. User s Guide FIBRE CHANNEL HBA INSTALLATION

Size: px
Start display at page:

Download "[ User s Guide] QLA 200 Family. User s Guide FIBRE CHANNEL HBA INSTALLATION"

Transcription

1 [ User s Guide] User s Guide FIBRE CHANNEL HBA INSTALLATION P QLA 200 Family Covers the following operating systems: Windows 2000 Windows Server 2003 Red Hat Linux SuSE Linux NetWare

2 Technical Support Customers should contact their authorized maintenance provider for technical support of their QLogic products. QLogic-direct customers may contact QLogic Technical Support; others will be redirected to their authorized maintenance provider. Availability Training Contact Information Visit the QLogic support Web site listed in Contact Information section for the latest firmware and software updates. QLogic Technical Support is available from 7:00 AM to 7:00 PM Central Standard Time, Monday through Friday, excluding QLogic-observed holidays. QLogic offers certification training for the technical professional for both the SANblade HBAs and the SANbox switches. From the training link at you may choose Electronic-Based Training or schedule an intensive "hands-on" Certification course. Technical Certification courses include installation, maintenance and troubleshooting QLogic SAN products. Upon demonstrating knowledge using live equipment, QLogic awards a certificate identifying the student as a Certified Professional. The training professionals at QLogic may be reached by at tech.training@qlogic.com. Address: QLogic Corporation 6321 Bury Drive Eden Prairie, Minnesota USA Telephone: Fax: Technical Support Technical Training HBA support web site: support@qlogic.com tech.training@qlogic.com support.qlogic.com Use the following table to write down the serial numbers of your QLA200 HBAs. This information is useful for QLogic technical support and for your HBA warranty. HBA Serial Number HBA Serial Number

3 QLA200 User s Guide 2-Gbps Fibre Channel to PCI-X Host Bus Adapter FL B Page i

4 QLA200 User s Guide 2-Gb Fibre Channel to PCI-X Host Bus Adapter Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document. No part of this document may be copied nor reproduced by any means, nor translated nor transmitted to any magnetic medium without the express written consent of QLogic Corporation. Linux is a registered trademark of Linus Torvalds. Microsoft, Windows NT, Windows Server, Windows 2000, and Windows Server 2003, are trademarks or registered trademarks of Microsoft Corporation. QLA, QLogic, and the QLogic logo are registered trademarks of QLogic Corporation. Red Hat and all Red Hat-based trademarks are trademarks or registered trademarks of Red Hat, Inc. Solaris is a registered trademark of Sun Microsystems, Inc. SuSE is a registered trademark of SuSE Linux AG. WinZip is a registered trademark of WinZip Computing, Inc. All other brand and product names are trademarks or registered trademarks of their respective owners. Document Revision History Rev A release, 1/20/04 Rev B update, 4/9/04 Changes Document Sections Affected Re-format/re-design guide All Updated QLA200 information. 1 Updated HBA installation instructions 2 Updated instructions for driver installation in Windows operating systems 3 Updated instructions for driver installation in Red Hat/SuSE Linux operating 4 systems Added instructions for driver installation in NetWare operating systems 5 Revised hardware troubleshooting information Updated Fast!UTIL information QLogic Corporation. All rights reserved worldwide. First Printed: November 2003 Printed in U.S.A. QLogic Corporation, Aliso Viejo Parkway, Aliso Viejo, CA 92656, (800) or (949) Page ii FL B

5 Table of Contents Section 1 Introducing the QLA QLA200 HBA Highlights What s in the Box? QLA200 HBA Components System Requirements Installing the QLA200 HBA and Driver Section 2 HBA Installation 2.1 Installing the QLA200 HBA Section 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) 3.1 Introduction Installing the Driver Updating the Driver Removing the Driver Performing Diagnostics Section 4 Red Hat/SuSE Linux Driver Installation 4.1 Introduction Installing and Uninstalling the Driver with the Source RPM Package Installing the Source RPM Package Installing Only the Driver Source from the Source RPM Package Uninstalling the Source RPM Package System Driver Parameter max_scsi_luns Multiple LUN Support Through the Kernel Multiple LUN Support when the SCSI Mid-Layer is Compiled in the Kernel Multiple LUN Support when the SCSI Mid-Layer is Compiled as a Module Proc Filesystem Support Section 5 NetWare Driver Installation 5.1 Introduction Finding the Driver Files FL B Page iii

6 QLA200 User s Guide 2-Gbps Fibre Channel to PCI-X Host Bus Adapter 5.3 Installing the Driver Installing the Driver During Installation of the NetWare Operating System Installing the Driver on an Existing NetWare Server Updating the Existing Driver on a NetWare Server Removing the Driver Removing the QLA200 HBA and the NetWare Driver Removing the NetWare Driver Driver Parameters System Parameters NVRAM Parameters Section 6 Troubleshooting 6.1 Problems After Installation Hardware Problems System Configuration Problems Fibre Channel Problems Section 7 Software Applications and Utilities 7.1 Introduction Configuration Settings Adapter Settings Selectable Boot Settings Restore Default Settings Scan Fibre Channel Devices Fibre Disk Utility Loopback Data Test Select Host Adapter Appendix A Compliance, Specifications, and Agency Certification A.1 Compliance A-1 A.2 Specifications A-1 A.3 Transceiver Label A-2 A.4 Agency Certification A-3 A.4.1 EMI and EMC Requirements (Preliminary) A-3 A.4.2 Product Safety Requirements (Preliminary) A-3 Page iv FL B

7 QLA200 User s Guide 2-Gbps Fibre Channel to PCI-X Host Bus Adapter Figure Figures Page 1-1 QLA200 HBA Kit QLA200 HBA Layout Low-Profile Bracket Installation QLA200 HBA Installation Connecting the Cable Found New Hardware Wizard Dialog Box SANsurfer Fibre Channel HBA Software Screen SANsurfer HBA Software Screen SANblade Fibre Channel HBA Management Software and Drivers Screen File Download Dialog Box (Sample) Initial Driver Installation Dialog Box Select Driver Dialog Box Driver Server Proxy Settings Dialog Box Driver Update Screen Install Status (Successful) Dialog Box Install Status (Unsuccessful) Dialog Box Driver Install Completed Dialog Box Driver Update Completed Dialog Box Select HBAs to Test Dialog Box Diagnostic Test Results Diagnostic Test Results, Detailed Table Tables Page 3-1 Driver Versions that Do Not Require a Loopback Connector QL2300.HAM Driver Parameters NVRAM Parameters Adapter Settings A-1 QLA200 Board Specifications A-1 A-2 QLA200 Board Operating Environment A-2 FL B Page v

8 QLA200 User s Guide 2-Gbps Fibre Channel to PCI-X Host Bus Adapter Notes Page vi FL B

9 Section 1 Introducing the QLA QLA200 HBA Highlights The following QLogic host bus adapter (HBA) is supported in this document: QLA 200 (single channel, full-height bracket, optical media) The QLA200 is 32-bit, 133-MHz PCI-X 1.0 to Fibre Channel optical media. The QLA200 HBA is a robust, dependable addition to your storage area network (SAN). The features and performance are optimized for small and medium enterprise (SME) markets. With auto-install software, plug-and-play features, and an enhanced level of technical support, the QLA200 HBA makes expanding your SAN easy and affordable. The QLA200 HBA has the following features: 2-Gbps Fibre Channel 133 MHz, 32-bit PCI-X support Integrated single-chip solution Enhanced reliability Support for bus master DMA Fast!UTIL BIOS utility to enable the BIOS, set the spinup delay, and enable extended error logging on the QLA200 HBA and attached drives Supports Fibre Channel protocol-scsi (FCP-SCSI) Supports point-to-point fabric connection (F-PORT FABRIC LOGIN) FL B 1-1

10 1 Introducing the QLA200 What s in the Box? 1.2 What s in the Box? Make sure you have everything you need to install the QLA200 HBA (see figure 1-1). SYSTEM SERVICE AND WARRANTY BROCHURE QUICK START GUIDE AND USER S GUIDE SANsurfer Fibre Channel HBA Software CD Not all of these items are included in a bulk box. SANblade QLA200 HBA LOW PROFILE BRACKET (NOT AVAILABLE IN ALL MODELS) Figure 1-1. QLA200 HBA Kit 1-2 FL B

11 1 Introducing the QLA200 QLA200 HBA Components 1.3 QLA200 HBA Components CAUTION! The QLA200 HBA contains parts that can be damaged by electrostatic discharge (ESD). Before handling the QLA200 HBA, use standard methods to discharge static electricity. Keep the QLA200 HBA in the antistatic bag until you are ready to install it. Place the board on the bag when you examine or configure it. Retain the bag for future use. Figure 1-2 identifies the QLA200 HBA components referenced throughout this section. Each QLA200 HBA has a unique serial number; its location on the HBA is noted in figure 1-2. Take a minute to write down the serial number of the QLA200 HBA on the inside cover of this document. The serial number is required for QLogic technical support and for your HBA warranty. Green LED Yellow LED Power off Power Online Link established Flashing twice per second Loss of synchronization Green and Yellow LEDs flashing alternately twice per second Activity SERIAL NUMBER Firmware error LEDs TRANSCEIVER Figure 1-2. QLA200 HBA Layout FL B 1-3

12 1 Introducing the QLA200 System Requirements 1.4 System Requirements Your system must have the following functionality to support the QLA200 HBA: One of the following: PCI 32-bit data and 33/66 MHz clock frequency PCI-X and 66/100/133 MHz clock frequency 3.3-volt signaling (5-volt tolerant) The correct media (short wave 50µm fiber or 62.5µm fiber) and connectors (LC duplex) 1.5 Installing the QLA200 HBA and Driver Installing your QLA200 HBA is quick and easy: First, install the QLA200 HBA according to the directions in section 2. Second, install the software driver according to the directions in the section that corresponds to your computer s operating system: Operating System Section Windows 2000/Windows Server Red Hat /SuSE Linux 4 Novell NetWare FL B

13 Section 2 HBA Installation 2.1 Installing the QLA200 HBA Perform the following steps to install the QLA200 HBA in your PC: Step 1. Prepare the system for the QLA200 HBA. Power down the peripherals, then the computer. Remove the computer cover and save the screws. Check the motherboard and make any configuration changes necessary to accommodate the QLA200 HBA. The QLA200 HBA is self-configuring; however, some motherboards require manual configuration. For example, some systems have a PCI Device Configuration menu in the motherboard setup BIOS where you must enable HBAs, bus master slots, and IRQ levels. If the motherboard supports triggering, use level triggering for the QLA200 HBA. See the documentation supplied with your computer, or contact your computer dealer to determine if your motherboard requires configuration. Choose any PCI bus slot that supports bus mastering. Most motherboards automatically assign an IRQ level and interrupt line; if your motherboard does not, you must assign the IRQ level and use interrupt line A for this slot. Remove the slot cover for the slot in which you will install the QLA200 HBA. FL B 2-1

14 2 HBA Installation Installing the QLA200 HBA Step 2. Install the low-profile bracket (optional). Remove the two screws that attach the current bracket to the HBA. Retain the screws to re-attach the new bracket (see figure 2-1). BRACKET SCREW SCREW Figure 2-1. Low-Profile Bracket Installation Remove the current bracket by sliding it off the transceiver housings. Set the bracket aside. Position the new bracket over the transceiver housings. Gently press the bracket into position. Make sure the mounting tabs with the threaded holes are positioned on the far side (the side opposite the transceiver) of the QLA200 HBA. Align the screw holes of the QLA200 HBA and the bracket, then insert and tighten the screws. Correct torque is 3.6-in/lbs. 2-2 FL B

15 2 HBA Installation Installing the QLA200 HBA Step 3. Install the QLA200 HBA (see figure 2-2). LEVER SCREW HBA RETAINING BRACKET QLA200 HBA 64-BIT PCI BUS OR 32-BIT PCI BUS SLOT COVERS SYSTEM CHASSIS Figure 2-2. QLA200 HBA Installation Place the QLA200 HBA into the slot. Carefully press the HBA into the slot until it seats firmly. Secure the QLA200 HBA to the chassis. Follow the PC manufacturer s instructions. Connect the Fibre Channel connectors to the QLA200 HBA; follow the instructions provided by your storage vendor (RAID box) (see figure 2-3). Cable Type Max. Length Min. Length 62.5/125 µm (LC, multimode) 50/125 µm (LC, multimode) 150 meters at Gpbs 2 meters 300 meters at Gpbs 2 meters Figure 2-3. Connecting the Cable Carefully reinstall the computer cover. Insert and tighten the computer cover screws. FL B 2-3

16 2 HBA Installation Installing the QLA200 HBA Step 4. Power up all external FC devices, then power up the PC and observe the monitor. By default, the BIOS is disabled. Therefore, the devices attached to the QLA200 HBA are not displayed when the PC is powered up. For example: QLogic Corporation QLA200 PCI Fibre Channel ROM BIOS Version x.xx Copyright (C) QLogic Corporation 2004 All rights reserved. Press <CNTRL-Q> for Fast!UTIL BIOS for Adapter 0 is disabled ROM BIOS not installed Enable the BIOS only if the boot device is attached to the QLA200 HBA. This allows the system to boot faster. NOTE For more information about enabling the QLA200 HBA BIOS, see section 7. Congratulations! You have successfully installed your QLogic HBA! You are now ready to install the HBA driver. See the appropriate section for detailed instructions on how to install the software drivers. Operating System Section Windows 2000/Windows Server Red Hat /SuSE Linux 4 Novell NetWare 5 If the information displayed is not correct and you have checked the QLA200 HBA s configuration, see section 6 for troubleshooting information. See section 7 for detailed instructions on how to customize the QLA200 HBA and its attached devices using the Fast!UTIL BIOS utility. 2-4 FL B

17 Section 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) 3.1 Introduction 3.2 Installing the Driver The SANsurfer HBA Install Wizard does the following: Installs the QLA200 HBA driver for Windows 2000/Server 2003 operating systems (see section 3.2) Updates the QLA200 HBA driver for Windows 2000/Server 2003 operating systems (see section 3.3). (To remove the driver, see section 3.4.) Performs diagnostics on the QLA200 HBA and its attached devices (see section 3.5) The SANsurfer HBA Install Wizard is on the SANsurfer Fibre Channel HBA Software CD-ROM (CD), and can be run from the CD at any time. To run the wizard from the server (optional), see the instructions in section 3.2. If you have installed the QLA200 HBA in a Windows 2000/Server 2003 operating system, follow these instructions to launch the SANsurfer HBA Install Wizard, which installs the HBA driver automatically. When the system is powered on, the Microsoft Found New Hardware Wizard dialog box (plug-and-play installation process) may display (see figure 3-1). Click Cancel. You may have multiple NOTE dialog boxes if more than one QLA200 HBA is installed in the system. Click Cancel in each dialog box. Figure 3-1. Found New Hardware Wizard Dialog Box FL B 3-1

18 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Installing the Driver Step 1. Insert the SANsurfer Fibre Channel HBA Software CD in an appropriate drive. The SANsurfer Fibre Channel HBA Software screen displays (see figure 3-2). Figure 3-2. SANsurfer Fibre Channel HBA Software Screen If the SANsurfer Fibre Channel HBA Software screen does not display, do the following: Select the drive where the SANsurfer Fibre Channel HBA Software CD is located. Locate and double-click the Start_Here.htm file. Step 2. Click Drivers and Application. The SANsurfer HBA Software screen displays (see figure 3-3). Figure 3-3. SANsurfer HBA Software Screen 3-2 FL B

19 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Installing the Driver Step 3. In the table titled 2Gb FC - QLA200 Series, click the appropriate operating system: Windows 2000 or Windows Server The SANblade Fibre Channel HBA Management Software and Drivers screen displays (see figure 3-4). Figure 3-4. SANblade Fibre Channel HBA Management Software and Drivers Screen Step 4. In the table titled 2Gb FC - QLA200 Series, click Click Here to Install. The File Download dialog box displays (see figure 3-5). Figure 3-5. File Download Dialog Box (Sample) Step 5. You can run the SANsurfer HBA Install Wizard from the CD. Optionally, you can download the wizard to the server and run it from there. Do one of the following: Click Open or Run to run the SANsurfer HBA Install Wizard from the CD. Click Save to download the application to the computer s hard disk. The Save As dialog box displays. Specify a location on the hard disk, then click Save. From that location, double-click the installation file qlflzip.exe. The SANsurfer HBA Install Wizard starts automatically. If the wizard does not start and you are running the wizard from the CD, do the following: Select the drive where the SANsurfer Fibre Channel HBA Software CD is located. In the \data\files\windows directory, double-click the installation file qlflinst.exe. FL B 3-3

20 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Installing the Driver Step 6. The Initial Driver Installation dialog box displays (see figure 3-6). Click Install Driver to continue with the driver installation. Figure 3-6. Initial Driver Installation Dialog Box Step 7. The Select Driver dialog box displays (see figure 3-7). Figure 3-7. Select Driver Dialog Box Select the driver location by selecting one the following radio buttons: Default Driver (provided with wizard), From the Qlogic website, or Browse. If your system has internet access, QLogic recommends selecting the From the QLogic website radio button. NOTE Select Browse if you previously downloaded the driver to your hard disk. 3-4 FL B

21 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Installing the Driver If you select the From the QLogic website button and your system has a proxy server, select the Specify Proxy Settings check box. The Server Proxy Settings dialog box displays (see figure 3-8). Figure 3-8. Driver Server Proxy Settings Dialog Box Select the Use the following HTTP proxy setting check box. Enter the server name and address in the Address box. For example: proxy.mylan.com or Enter the port number where the server software is monitoring. Valid values are in the range Click Continue to proceed with the driver installation. The Driver Update screen displays while the system installs the driver (see figure 3-9). Figure 3-9. Driver Update Screen Step 8. One of the following dialog boxes displays: If the driver is installed successfully, the following Update Status dialog box displays (see figure 3-10). Click OK. Figure Install Status (Successful) Dialog Box FL B 3-5

22 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Installing the Driver If the driver does not install successfully, the following Install Status dialog box displays (see figure 3-11). Click OK. Figure Install Status (Unsuccessful) Dialog Box There are three reasons why the driver installation can fail: The OS cannot find the QLA200 HBA. Make sure that the QLA200 HBA is seated properly (be sure to power down the computer before checking the HBA). Next, use the Device Manager to verify that the OS sees the QLA200 HBA. If the HBA does not display, use the Scan for Hardware wizard from the Device Manager. Internet problems. If you selected the From the Qlogic website radio button in the Select Driver dialog box and the your PC did not connect to the QLogic web site, the problem may be with the internet connection. Install the default driver (select the Default Driver (provided with wizard) radio button in the Select Driver dialog box). If this installation works, the internet connection is not working. If this installation does not work, the problem could be a software bug (see the next paragraph). Software problems. If the driver cannot install successfully, there may be a problem with the driver or the SANsurfer HBA Install Wizard. Contact QLogic Technical Support. Step 9. If the operating system determines that a reboot is necessary, the Driver Install Completed dialog box displays (see figure 3-12). Wait for the system to reboot in 30 seconds, or click Reboot now. Figure Driver Install Completed Dialog Box Step 10.After the driver is installed, the SANsurfer HBA Install Wizard automatically exits. 3-6 FL B

23 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Updating the Driver 3.3 Updating the Driver Perform the following steps if a Windows 2000/Server 2003 driver is already installed and you want to install an updated version of the driver: You must have internet access if you want to update the driver from the QLogic web site. NOTE Step 1. Insert the SANsurfer Fibre Channel HBA Software CD in an appropriate drive. The SANsurfer Fibre Channel HBA Software screen displays. Step 2. Click Drivers and Application. The SANsurfer HBA Software screen displays. Step 3. In the table titled 2Gb FC - QLA200 Series, click the appropriate operating system: Windows 2000 or Windows Server The SANblade Fibre Channel HBA Management Software and Drivers screen displays. Step 4. In the table titled 2Gb FC - QLA200 Series, click Click Here to Install. The File Download dialog box displays. Step 5. You can run the SANsurfer HBA Install Wizard from the CD. Optionally, you can download the wizard to the server and run it from there. Do one of the following: Click Open or Run to run the SANsurfer HBA Install Wizard from the CD. Click Save to download the application to the computer s hard disk. The Save As dialog box displays. Specify a location on the hard disk, then click Save. From that location, double-click the installation file qlflzip.exe. The SANsurfer HBA Install Wizard starts automatically. If the wizard does not start and you are running the wizard from the CD, do the following: Select the drive where the SANsurfer Fibre Channel HBA Software CD is located. In the \data\files\windows directory, double-click the installation file qlflinst.exe. Step 6. The HBA Configuration Update dialog box displays. Step 7. Click Update Driver. Continue with step 7 in section 3.2. FL B 3-7

24 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Removing the Driver After the driver is updated, you may need to reboot the system. If so, the Driver Update Completed dialog box displays (see figure 3-13). Wait for the system to reboot in 30 seconds, or click Reboot now. If the PC has applications running in the background and you want to close them, click Cancel Reboot. However, the installation will not be complete until the system is rebooted. Figure Driver Update Completed Dialog Box 3.4 Removing the Driver Power down your computer and remove the HBA from your computer according to the manufacturer s instructions; the HBA removal also removes the driver. You do not have to use the Device Manager, Hardware Wizard, or SANsurfer HBA Install Wizard to uninstall the QLA200 HBA. After you have removed the HBA and restarted your computer, Windows NOTE 2000/Server 2003 recognizes that the HBA has been removed. Alternately, you can use the Device Manager to remove the driver, which disconnects the QLA200 HBA from its attached devices. However, this procedure is not recommended for other QLogic HBAs, because the Windows 2000/Server 2003 OS will substitute its own driver when the system is powered up. The OS driver may not be the latest version of the driver. 3.5 Performing Diagnostics The SANsurfer HBA Install Wizard performs the following diagnostic tests on the QLA200 HBA and its attached devices: Loopback. This test uses the Diagnostic Loopback mailbox command to send and receive data. Before running this test, the loop in the Fibre Channel port must be up or a loopback connector must be installed. The test evaluates the ports (transmit and receive transceivers) on the QLA200 HBA. More specifically, the loopback test transmits and receives (loopback) the data and checks for the frame CRC, disparity, and length errors. 3-8 FL B

25 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Performing Diagnostics A loopback connector is not required if your operating system has one of the driver versions listed in table 3-1. Table 3-1. Driver Versions that Do Not Require a Loopback Connector Operating System Driver Version a Windows 2000/Server 2003 with SCSI miniport driver Windows Server 2003 with STORport miniport driver Table Notes a All subsequent versions also apply. Read/Write Buffer. The read/write buffer test sends specified data through the SCSI Write Buffer command to a target device or tape. It then reads the data back through the SCSI Read Buffer command and compares the data for errors. The test also compares the link status of the device or tape before and after the read/write buffer test. If errors occur, the test indicates a broken or unreliable link between the adapter and the device/tape. Perform the following steps to run a loopback test and a read/write buffer test on the QLA200 HBA and its attached devices: Step 1. Insert the SANsurfer Fibre Channel HBA Software CD in an appropriate drive. The SANsurfer Fibre Channel HBA Software screen displays. Step 2. Click Drivers and Application. The SANsurfer HBA Software screen displays. Step 3. In the table titled 2Gb FC - QLA200 Series, click the appropriate operating system: Windows 2000 or Windows Server The SANblade Fibre Channel HBA Management Software and Drivers screen displays. Step 4. In the table titled 2Gb FC - QLA200 Series, click Click Here to Install. The File Download dialog box displays. Step 5. You can run the SANsurfer HBA Install Wizard from the CD. Optionally, you can download the wizard to the server and run it from there. Do one of the following: Click Open or Run to run the SANsurfer HBA Install Wizard from the CD. Click Save to download the application to the computer s hard disk. The Save As dialog box displays. Specify a location on the hard disk, then click Save. From that location, double-click the installation file qlflzip.exe. FL B 3-9

26 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Performing Diagnostics The SANsurfer HBA Install Wizard starts automatically. If the wizard does not start and you are running the wizard from the CD, do the following: Select the drive where the SANsurfer Fibre Channel HBA Software CD is located. In the \data\files\windows directory, double-click the installation file qlflinst.exe. Step 6. The HBA Configuration Update dialog box displays. Step 7. Click Diagnostics. The select HBAs to test dialog box displays (see figure 3-14). The QLA200 HBAs are listed by port number. Figure Select HBAs to Test Dialog Box Step 8. Choose the HBAs you want to test by clicking the appropriate box in the Select column. Click Next. Step 9. A loopback test and a read/write buffer test are run on the selected HBAs. The results are displayed (see figure 3-15). Figure Diagnostic Test Results 3-10 FL B

27 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Performing Diagnostics For more information, right-click the port number in the Adapter column. More detailed diagnostic results are displayed (see figure 3-16). Figure Diagnostic Test Results, Detailed NOTE Click Close. Be sure to remove the loopback connector when you are done running diagnostic tests. FL B 3-11

28 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003) Performing Diagnostics Notes 3-12 FL B

29 Section 4 Red Hat/SuSE Linux Driver Installation 4.1 Introduction This section provides instructions for installing QLogic drivers on the following Linux operating systems: Red Hat Linux Advanced Server 2.1 and Enterprise Linux 3.0. Earlier or later versions of Red Hat Linux are not currently supported. SuSE Linux enterprise server (SLES) (version 8). Earlier or later SuSE SLES versions are not supported. The latest version of the software drivers and documentation for Red Hat Linux are available on the SANsurfer Fibre Channel HBA Software CD and the QLogic Web site, support.qlogic.com. Be sure to review the README.qla2x00 and release.txt files for both new and changed information. To install the Red Hat/SuSE Linux driver, first mount the source RPM package, then build the driver from the package, as described in the following sections. 4.2 Installing and Uninstalling the Driver with the Source RPM Package Install and build the QLogic Linux driver from the source RPM package. The only requirement for the RPM is the kernel-source, which is usually installed when the kernel is installed on the system. The driver source is installed in the /usr/src/qla2x00 path when the source RPM is installed. NOTE If the kernel-source is missing, see the instructions in the README.qla2x00 file. FL B 4-1

30 4 Red Hat/SuSE Linux Driver Installation System Driver Parameter max_scsi_luns Installing the Source RPM Package Perform the following steps to mount the source RPM package and install the driver source: Step 1. Insert the SANsurfer Fibre Channel HBA Software CD in an appropriate drive. Step 2. Type the following command to mount the SANsurfer Fibre Channel HBA Software CD: # mount /dev/cdrom Step 3. Type the following command: For RedHat Linux: # cd /mnt/cdrom/data/files/linux # ls For SuSE Linux: # cd /media/cdrom/data/files/linux # ls Step 4. To install the source RPM package, type the following command: # rpm -i qla2x00-vx.xx.xxbxx-y.zzzz.rpm Installing Only the Driver Source from the Source RPM Package Type the following command to install only the driver source from the source RPM package: # rpm -i --noscripts qla2x00-vx.xx.xxbxx-y.zzz.rpm Uninstalling the Source RPM Package Uninstall the source RPM package by typing the following command: # rpm -e qla2x00-vx.xx.xxbxx-y 4.3 System Driver Parameter max_scsi_luns Support for multiple LUNs can be configured as follows: Through the kernel (see section 4.3.1) When the SCSI Mid-Layer is compiled in the kernel (see section 4.3.2) When the SCSI Mid-Layer is compiled as a module (see section 4.3.3) Currently, the maximum number of LUNs that can be scanned for each device is FL B

31 4 Red Hat/SuSE Linux Driver Installation System Driver Parameter max_scsi_luns Multiple LUN Support Through the Kernel The kernel must be configured to enable multiple LUN support so that nonzero LUNs can be configured and accessible. Use the make menuconfig command to build a kernel that has the option under SCSI Support enabled to probe all LUNs on SCSI devices. If you have multiple HBAs, set max_scsi_luns to the largest number of LUNs supported by any one of these HBAs. NOTE Multiple LUN Support when the SCSI Mid-Layer is Compiled in the Kernel If the SCSI Mid-Layer is compiled in the kernel, the boot loader can be configured to scan for multiple LUNs each time the system boots. For LILO IA-32 systems, perform the following steps: Step 1. Add the following line to each of the kernel images listed in the /etc/lilo.conf file: append="max_scsi_luns=128" Step 2. Type the following command: # lilo Step 3. Reboot the system. For GRUB IA-32 Red Hat systems, perform the following steps: Step 1. Append the max_scsi_luns parameter to each of the kernel images listed in the /etc/grub.conf file. For example: kernel /vmlinux ro root=/dev/hda2 max_scsi_luns=128 Step 2. Reboot the system. For GRUB IA-32 SuSE systems, perform the following steps: Step 1. Append the max_scsi_luns parameter to each of the kernel images listed in the /boot/grub/menu.lst file. For example: kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 max_scsi_luns=128 Step 2. Reboot the system. FL B 4-3

32 4 Red Hat/SuSE Linux Driver Installation Proc Filesystem Support For an IA-64 Red Hat system, perform the following steps: Step 1. Add the following line to each of the kernel images listed in the /boot/efi/efi/redhat/elilo.conf file: append="max_scsi_luns=128" Step 2. Reboot the system. For an IA-64 SuSE system, perform the following steps: Step 1. Add the following line to each of the kernel images listed in the /boot/efi/suse/elilo.conf file: append="max_scsi_luns=128" Step 2. Reboot the system Multiple LUN Support when the SCSI Mid-Layer is Compiled as a Module If the SCSI Mid-Layer is compiled as a module, perform the following steps: Step 1. Add the following line to the /etc/modules.conf file to scan for multiple LUNs when the system boots: options scsi_mod max_scsi_luns=128 Step 2. Rebuild the RAMDISK image. 4.4 Proc Filesystem Support The /proc filesystem for the driver can be found in the /proc/scsi/qla2300/ directory. This directory contains a file for each QLogic Fibre Channel HBA in the system. Each file presents information about the adapter and transfer statistics for each discovered LUN. 4-4 FL B

33 5.1 Introduction Section 5 NetWare Driver Installation This section provides instructions for installing QLogic drivers on a NetWare 5.x or 6.x operating system (OS). 5.2 Finding the Driver Files The NetWare driver files are located on the SANsurfer QLA200 (CD) and on the QLogic web site. Be sure to check the QLogic web site for the most up-to-date version of the driver. This section describes how to download the driver from the QLogic web page or the SANsurfer Fibre Channel HBA Software CD to a floppy disk (disk). During Netware OS installation, the driver must be on a disk, since you cannot swap CDs during the installation. NOTE Follow these steps to download the driver from the QLogic web page or the SANsurfer Fibre Channel HBA Software CD to a disk for installation: Step 1. Do one of the following: Locate the driver you want on the QLogic web site (support.qlogic.com) and click Download. From the SANsurfer Fibre Channel HBA Software CD home page, click Driver and Application. In the table titled 2Gb FC - QLA200 Series, locate the Operating System column. Click NetWare. The SANblade Fibre Channel HBA Software and Drivers screen displays. Click Download. Step 2. If prompted Would you like to open the file or save it to your computer?, click Save. Specify a temporary location on the hard drive and download the self-extracting file. Step 3. Insert a disk in an appropriate drive. Step 4. Run the self-extracting file you just downloaded. Extract the files to the following directory on the disk: A:\NWUPDATE\DRIVERS After the file has extracted, verify that the QL2300.HAM and QL2300.DDI files are in the \NWUPDATE\DRIVERS directory. Step 5. Remove the disk and take it to the NetWare server. FL B 5-1

34 5 NetWare Driver Installation Installing the Driver 5.3 Installing the Driver This section describes four NetWare driver installation options: Installing the driver during installation of the NetWare operating system (see section 5.3.1) Installing the driver on an existing NetWare server (see section 5.3.2) Updating the existing driver on a NetWare server (see section 5.3.3) Installing the Driver During Installation of the NetWare Operating System Perform the following steps to initially install the NetWare OS and the NetWare driver: Step 1. If you have not already done so, install the QLA200 HBA (see section 2). Step 2. Insert the driver disk (created in section 5.2) and the NetWare OS install CD into the NetWare server. Power up the server. Step 3. Follow the standard NetWare instructions to begin the installation. Step 4. Do one of the following: If the server will be booting from a device attached to the QLA200 HBA, perform the following steps to enable the BIOS and specify the boot device: a. Start Fast!UTIl (see section 7.1). b. Enable the BIOS (see section 7.2.1). c. Specify the boot device (see section 7.2.2). d. Exit Fast!UTIL. If the server is booting from a device that is not attached to the QLA200 HBA, perform the following steps to disable the BIOS: a. Start Fast!UTIl (see section 7.1). b. Disable the BIOS (see section 7.2.1). c. Exit Fast!UTIL. Step 5. After the Netware OS installation is complete, restart the server. 5-2 FL B

35 5 NetWare Driver Installation Installing the Driver Installing the Driver on an Existing NetWare Server Perform the following steps to add the NetWare driver to the existing NetWare system: Step 1. If you have not already done so, install the QLA200 HBA (see section 2). Step 2. Insert the driver disk (created in section 5.2) into the NetWare server. Power up the server. The HWDETECT or NWCONFIG program automatically detects the QLA200 HBA, and locates and loads the driver. If the programs do not find the driver (the QL2300.HAM file is missing from the Storage adapters: field of the drivers page), follow the instructions in section to manually install the driver files Updating the Existing Driver on a NetWare Server The HWDETECT or NWCONFIG program should find and prompt you to install the updated driver. If the programs do not find the driver (the QL2300.HAM file is missing from the Storage adapters: field of the drivers page), perform the following steps to manually install the driver files: Step 1. Insert the driver disk created in section 5.2. Step 2. Use either the NetWare Remote Manager or the DOS copy command to copy the files from the driver disk to the NetWare server. NetWare Remote Manager: a. Start the NetWare Remote Manager from the NetWare GUI (execute STARTX). b. Copy the QL2300.HAM and QL2300.DDI files (drag and drop) from the disk to the following directories on the server: C:\NWSERVER\DRIVERS (NetWare 6.x) C:\NWSERVER (NetWare 5.x) DOS Copy Command: a. Start at the DOS prompt. If your server does not stop at the DOS prompt, press the F8 key when the Starting DOS or Starting Caldera DR-DOS message displays during a hardware boot. If you miss the message, press CTRL+ALT+DELETE, then wait for the message to re-display. FL B 5-3

36 5 NetWare Driver Installation Removing the Driver When prompted, press Y in answer to all questions except SERVER (Y/N)?. When prompted SERVER (Y/N)?, press N. b. Copy the QL2300.HAM and QL2300.DDI files from the disk to the following directories on the server: C:\NWSERVER\DRIVERS (NetWare 6.x) C:\NWSERVER (NetWare 5.x) Make sure the QL2300.HAM and QL2300.DDI files are in the C: directory. Step 3. Start the server and manually load the driver once for each QLA200 HBA in the system. Each time you load the driver, note the slot number for future reference. Step 4. Start NWCONFIG. Select NCF Files Options. Select Edit STARTUP.NCF File to edit the file STARTUP.NCF. Step 5. At the end of the STARTUP.NVF file, append the following load line once for each QLA200 HBA in the system, using the slot number written down from step 3: LOAD QL2300.HAM SLOT=n /LUNS /ALLPATHS /PORTNAMES /QUALIFIED For example, if you have two QLA200 HBAs in slots 2 and 3, add the following lines: LOAD QL2300.HAM SLOT=2 /LUNS /ALLPATHS /PORTNAMES /QUALIFIED LOAD QL2300.HAM SLOT=3 /LUNS /ALLPATHS /PORTNAMES /QUALIFIED Step 6. Exit the editor (save the changes you made). Step 7. Exit NWCONFIG. 5.4 Removing the Driver Step 8. Restart the NetWare server. There are two ways to remove the NetWare driver: Removing the QLA200 HBA and the NetWare driver (see section 5.4.1) Removing the NetWare driver (see section 5.4.2) 5-4 FL B

37 5 NetWare Driver Installation Removing the Driver Removing the QLA200 HBA and the NetWare Driver If you are removing the QLA200 HBA from the server, perform the following steps: Step 1. Remove the QLA200 HBA from the server hardware. Step 2. Power on the server. Start the NetWare server if it does not start automatically. Step 3. The HWDETECT program automatically detects that the QLA200 HBA has been removed, and consequently removes the driver load instance. If HWDETECT does not remove the driver, perform the steps in section Removing the NetWare Driver If you are not removing the QLA200 HBA from the server, or you removed the QLA200 HBA and HWDETECT did not remove the driver load instance, perform the following steps: Step 1. Start NWCONFIG. Select NCF Files Options. Select Edit STARTUP.NCF File to edit the file STARTUP.NCF. Step 2. At the start of each line that loads the QL2300.HAM file (there is one line for each QLA200 HBA in the server), insert a pound sign (#) to comment out that line. Spaces are allowed after the pound character; be sure to add the space on all lines that load the NetWare driver. The following example lists the load lines for two driver instances commented out with the pound sign (#): # LOAD QL2300.HAM SLOT=2 /LUNS # LOAD QL2300.HAM SLOT=3 /LUNS Step 3. Exit the editor (save the changes you made). Step 4. Exit NWCONFIG. Step 5. Restart the NetWare server. When you want to reload the QLogic driver, use NWCONFIG (see step 1) to edit the STARTUP.NCF file. Remove the pound sign (#) that you inserted in step 1. Exit the editor (save any changes you made), exit NWCONFIG, and restart the server. FL B 5-5

38 5 NetWare Driver Installation Driver Parameters 5.5 Driver Parameters System Parameters The NetWare driver has two types of optional parameters: System parameters (specified when the driver is loaded) (see section 5.5.1) NVRAM parameters (stored in the HBA s NVRAM) (see section 5.5.2) The optional system parameters are specified on the driver load line. There are two types of system parameters: Global. The parameter applies to all driver instances; the value specified in the first instance is used globally for all instances. Instance. The parameter applies only to the individual driver instance specified by the load line. The system parameters are described in table 5-1. Table 5-1. QL2300.HAM Driver Parameters Parameter Type Description SLOT = n Instance This parameters tells NetWare the PCI slot number (n) of the HBA on which to load this driver instance. SLOT=n parameter example: LOAD QL2300.HAM SLOT=3 /LUNS Instance This parameter tells NetWare to scan for all LUNs when this driver is loaded. Otherwise, NetWare scans only for LUN zero devices. The scanned LUN number range is 0 to (n 1), where n is specified by the /MAXLUNS=n option. /LUNS parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /GANXT Instance This parameter queries the fabric name server; it is used instead of a single GNNFT parameter. /GANXT is used for compatibility with name servers that do not support GNNFT. /GANXT parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /GANXT /ALLPATHS Global This parameter disables failover and reports to NetWare all devices on all HBA paths, which allows upper layer modules to do failover across a Netware server's multiple HBAs. /ALLPATHS parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /ALLPATHS 5-6 FL B

39 5 NetWare Driver Installation Driver Parameters Table 5-1. QL2300.HAM Driver Parameters (Continued) Parameter Type Description /PORTNAMES Global This parameter internally tracks devices by port name rather than node name, which is required when storage LUNs do not have a 1:1 correspondence across port names. Tracking devices by port name allows upper layer modules to do failover across a storage subsystem's multiple ports. /PORTNAMES parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /PORTNAMES /PORTDOWN=n Global This parameter sets the port down timeout period to n seconds, which is the timeout period for storage port down. When the timeout expires, failover is triggered if multiple ports are available. /PORTDOWN=n parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /PORTDOWN=n /LINKDOWN=n Global This parameter sets the link down timeout period to n seconds, which is the timeout period for adapter link down. When this timeout expires, adapter path failover is enabled if multiple ports are available. /LINKDOWN=n parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /LINKDOWN=n /FAILBACK=n Global This parameter sets the failback delay time period to n seconds. This is the time period that elapses when a port update event has occurred before any attempt is made to failback paths/ports. /FAILBACK parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /FAILBACK=n /BACKOFF Global This parameter disables failback of I/O after a broken link or a broken port has been restored and made operational. /BACKOFF parameter example: LOAD QL2300.HAM SLOT=3 /LUNS/BACKOFF /IGNCFG Global This parameter avoids reading the configuration file QL2X00.CFG, and allows all devices to be reported to NetWare. The QL2X00.CFG file is located in the default DOS directory (C:\NWSERVER); this file is written by QLogic SANsurfer software or the CFG.NLM test tool. /IGNCFG parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /IGNCFG FL B 5-7

40 5 NetWare Driver Installation Driver Parameters Table 5-1. QL2300.HAM Driver Parameters (Continued) Parameter Type Description /REQCFG Global This parameter requires reading the configuration file QL2X00.CFG. All devices not specified in this file are ignored. If this file does not exist, all devices are ignored. The QL2X00.CFG file is located in the default DOS directory (C:\NWSERVER); this file is written by QLogic SANsurfer software or the CFG.NLM test tool. /REQCFG parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /REQCFG /CONSOLE Global This parameter sends system alerts to the server console when failover and failback events occur. /CONSOLE parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /CONSOLE /MAXLUNS=n Global This parameter sets the maximum number of LUNs allowed during the LUN scan. The range of LUNs searched is 0 to (n 1). /MAXLUNS parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /MAXLUNS=256 /SKIPREPORT Instance This parameter avoids executing the SCSI Report LUNs command during LUN scanning. Omitting this parameter allows the driver to use the response from the SCSI Report LUNS command to optimize the LUN scan by performing SCSI Inquiry commands only to LUNs listed in the response. /SKIPREPORT parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /SKIPREPORT /INQUIRY Instance This parameter forces the use of SCSI Inquiry commands during the LUN scan regardless of the LUNs listed by the response to the SCSI Report LUNs command. The existence of a particular LUN is determined by the results of the SCSI Inquiry command to that LUN. /INQUIRY parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /INQUIRY /STARTUNIT Instance This parameter sends the SCSI Start Unit command to each LUN during the LUN scan. On some multiple port RAID subsystems, this parameter may cause LUN ownership to transfer across ports. /STARTUNIT parameter example: LOAD QL2300.HAM SLOT=3 /LUNS /STARTUNIT 5-8 FL B

FC HBA Driver for NetWare. Table of Contents

FC HBA Driver for NetWare. Table of Contents FC HBA Driver for NetWare This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. OS Support 3. Supported Features 4. Using

More information

Hardware Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus

Hardware Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus Hardware Installation Guide for the QLA22xx Board Family Fibre Channel Host Adapter Boards for the PCI Bus FC0151103-00 E February 6, 2001 QLogic Corporation Information furnished in this manual is believed

More information

SANsurfer iscsi HBA Application User s Guide

SANsurfer iscsi HBA Application User s Guide Q Simplify SANsurfer iscsi HBA Application User s Guide Management Application for SANsurfer iscsi Host Bus Adapters IS0054602-00 A Page i SANsurfer iscsi HBA Application User s Guide Management Application

More information

Software Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus

Software Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus Software Installation Guide for the QLA22xx Board Family Fibre Channel Host Adapter Boards for the PCI Bus FC0153302-00 F July 20, 2001 QLogic Corporation Information furnished in this manual is believed

More information

Appendix A Fast!UTIL

Appendix A Fast!UTIL Appendix A Fast!UTIL This appendix is part of the QLogic Corporation manual Hardware Installation Guide for the QLA1xxx Boards (PC0056105-00 E). The QLogic disclaimer and copyright notices for this document

More information

QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4. Table of Contents

QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4. Table of Contents QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4 Version: 7.07.05 OS Support : HBA Support: Red Hat RHEL 3 AS - Update 7 and Update 6 (IA32, EM64T, AMD64, IA64) Novell SLES

More information

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

SANsurfer Fibre Channel (FC) HBA Manager. Table of Contents

SANsurfer Fibre Channel (FC) HBA Manager. Table of Contents SANsurfer Fibre Channel (FC) HBA Manager This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. OS Support 2. Supported Features 3. Application

More information

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents SANsurfer Fibre Channel Command Line Interface (CLI) QLogic Corporation All rights reserved Table of Contents 1 Package Contents 2 Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3 OS

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters.

The Contents and Structure of this Manual. This document is composed of the following three chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

BIOS for QLA4010 iscsi HBAs. Table of Contents

BIOS for QLA4010 iscsi HBAs. Table of Contents BIOS for QLA4010 iscsi HBAs This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. OS Support 2. Supported Features 3. Creating the Driver

More information

Configuring the MSA1000 for Linux or NetWare Environments

Configuring the MSA1000 for Linux or NetWare Environments White Paper September 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the new firmware for the MSA1000...1 Prerequisites...3 Firmware Upgrades:...3 Environmental

More information

FC HBA STOR Miniport Driver for Windows. Table of Contents

FC HBA STOR Miniport Driver for Windows. Table of Contents FC HBA STOR Miniport Driver for Windows This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. 1. Package Contents 2. OS Support 3. Supported Features 4. Using

More information

Upgrading the MSA1000 for Enhanced Features

Upgrading the MSA1000 for Enhanced Features White Paper December 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the MSA1000 Enhancements...1 Prerequisites...3 Environmental Monitoring Unit (EMU) issue:...3

More information

[ Quick Start Guide ]

[ Quick Start Guide ] [ Quick Start Guide ] QUICK START GUIDE INTELLIGENT STORAGE ROUTER INSTALLATION z isr6250 Purchasers of OEM products should consult with the OEM for support. Please feel free to contact your QLogic approved

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents SANsurfer FC/CNA HBA Command Line Interface (CLI) QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3. OS

More information

Fibre Channel Adapter STOR Miniport Driver for Windows. Table of Contents

Fibre Channel Adapter STOR Miniport Driver for Windows. Table of Contents Fibre Channel Adapter STOR Miniport Driver for Windows QLogic Corporation All rights reserved Table of Contents 1. Package Contents 2. OS Support 3. Supported Features 4. Using the Driver 4.1 Creating

More information

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes Part number: AA-RVGWG-TE Sixth edition: July 2006 Legal and notice information

More information

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x QLogic Corporation. All rights reserved. Table of Contents 1. Version 2. Changes 3. Bug Fixes 4. Known Issues 5. Additional Information 6. History

More information

EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment

EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment P/N 300-001-162 REV A03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright

More information

SATA 150 Controller PCI Card user

SATA 150 Controller PCI Card user SATA 150 Controller PCI Card user manual Model 158046 MAN-158046-UM-0508-01 Thank you for purchasing this MANHATTAN SATA 150 Controller PCI Card, Model 158046. Compatible with esata and SATA 150/300 drives

More information

Technical White Paper iscsi Boot November 11, 2004

Technical White Paper iscsi Boot November 11, 2004 Technical White Paper iscsi Boot November 11, 2004 SN0032004-00 Rev A 11/04 Page 1 of 12 Table of Contents I. Executive Summary...3 II. Booting The Basics...3 Booting Options...3 Boot Methods Pros and

More information

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems Application Notes HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems Product Version: 8.00 Second Edition (January 2005) Part Number: AA RVGWC TE This

More information

hp StorageWorks Using the QLogic Driver for Single-path or Multi-path Failover Mode on Linux Systems

hp StorageWorks Using the QLogic Driver for Single-path or Multi-path Failover Mode on Linux Systems Application Notes hp StorageWorks Using the QLogic 7.00.03 Driver for Single-path or Multi-path Failover Mode on Linux Systems Product Version: 7.00.03 First Edition (May 2004) Part Number: AA RVGWA TE

More information

Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents

Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents Converged Network Adapter NDIS Miniport Driver for Windows 1. Package Contents 2. OS Support 3. Supported Features 4. Using the Driver 4.1 Creating the Driver Disk 4.2 Installing the Driver 4.3 Removing

More information

AHA-3980/3980W AHA-3985/3985W

AHA-3980/3980W AHA-3985/3985W Quick Reference: Hardware Installation AHA-3980/3980W AHA-3985/3985W MultiChannel PCI-to-SCSI RAID Adapters R This guide explains how to install the AHA -398x RAID adapters: the AHA-3980, AHA-3980W, AHA-3985,

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

[ Quick Start Guide ]

[ Quick Start Guide ] [ Quick Start Guide ] QUICK START GUIDE FIBRE CHANNEL SWITCH INSTALLATION z SANbox 5800V Series for Windows Operating Systems Purchasers of OEM products should consult with the OEM for support. Please

More information

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment November 2000 Copyright 2000 EMC Corporation. All rights reserved. No part of this publication may be reproduced

More information

Dell Host Bus Adaptor User s Guide

Dell Host Bus Adaptor User s Guide Dell Host Bus Adaptor User s Guide Regulatory Model: UCSE 900 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION

More information

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-8e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.3 DB15-000902-03 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

Broadcom NetXtreme Gigabit Ethernet Adapter Installation

Broadcom NetXtreme Gigabit Ethernet Adapter Installation Page 1 of 8 Broadcom NetXtreme Gigabit Ethernet Adapter Installation This guide provides the following information: Safety Precautions Installing the Broadcom Adapter Installing the Adapter Connecting

More information

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

DP SATA 6Gb/s PCIe i/e Quick Installation Guide DP SATA 6Gb/s PCIe i/e Quick Installation Guide Introducing the SATA 6Gb/s PCIe i/e The DP SATA 6Gb/s PCIe i/e adds 2 SATA 6Gb/s & a PATA connectors to PCIe-equipped computers. Features and Benefits Dual

More information

AHA PCI-to-Fast SCSI Host Adapter. Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs

AHA PCI-to-Fast SCSI Host Adapter. Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs R AHA-2920 PCI-to-Fast SCSI Host Adapter Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs Introduction This installation guide provides the instructions needed to install and

More information

QLogic Fibre Channel Adapter Stor Miniport Driver for Windows Server 2003/Windows XP Professional. Table of Contents

QLogic Fibre Channel Adapter Stor Miniport Driver for Windows Server 2003/Windows XP Professional. Table of Contents QLogic Fibre Channel Adapter Stor Miniport Driver for Windows Server 2003/Windows XP Professional This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table

More information

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9207-8e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.3 DB15-000859-04 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-8i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.2 DB15-000984-02 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

Intel PRO/1000 T IP Storage Adapter

Intel PRO/1000 T IP Storage Adapter Intel PRO/1000 T IP Storage Adapter Bringing Gigabit Ethernet to Network Storage Quick Installation Guide 1 Additional Information Online User Configuration Guide Online Services The User Configuration

More information

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9211-4i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-000852-01 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-16e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.2 DB15-000982-03 For a comprehensive list of changes to this document, see the Revision History.

More information

Installation Guide AHA-1540CP/1542CP. ISA-to-SCSI Plug and Play High-Performance Bus Master Host Adapter with SCSISelect Utility

Installation Guide AHA-1540CP/1542CP. ISA-to-SCSI Plug and Play High-Performance Bus Master Host Adapter with SCSISelect Utility R Installation Guide AHA-1540CP/1542CP ISA-to-SCSI Plug and Play High-Performance Bus Master Host Adapter with SCSISelect Utility 1 Introduction This Installation Guide explains how to install and configure

More information

DtS Data Migration to the MSA1000

DtS Data Migration to the MSA1000 White Paper September 2002 Document Number Prepared by: Network Storage Solutions Hewlett Packard Company Contents Migrating Data from Smart Array controllers and RA4100 controllers...3 Installation Notes

More information

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9207-4i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.1 DB15-000858-02 Revision History Version and Date Description of Changes Final Version 2.1, Updated

More information

Fibre Channel card Users Guide

Fibre Channel card Users Guide C122-E012-19EN PRIMEQUEST Fibre Channel card Users Guide 2G Fibre Channel PCI-X card (MC-08FC11/ MC-08FC71) 4G Fibre Channel PCI-X card (MC-08FC31/ MC-08FC41) 4G Fibre Channel PCI-express card (MC-08FC51/

More information

SAS e PCI Express to 12Gb/s SAS Host Bus Adapter

SAS e PCI Express to 12Gb/s SAS Host Bus Adapter SAS 9305-16e PCI Express to 12Gb/s SAS Host Bus Adapter User Guide Version 1.1 pub-005244 For a comprehensive list of changes to this document, see the Revision History. Corporate Headquarters San Jose,

More information

HP StorageWorks QLogic host bus adapters for x86 and x64 Linux and Windows and x86 NetWare release notes

HP StorageWorks QLogic host bus adapters for x86 and x64 Linux and Windows and x86 NetWare release notes HP StorageWorks QLogic host bus adapters for x86 and x64 Linux and Windows and x86 NetWare release notes Part number: AV-RSBNV-TE Twentieth edition: January 2007 Description These release notes contain

More information

Dell EMC Host Bus Adapter User's Guide

Dell EMC Host Bus Adapter User's Guide Dell EMC Host Bus Adapter User's Guide HBA330 and External 12 Gbps SAS HBA Regulatory Model: UCSE 900, UCSF-1000, UCSN-1000 Notes, cautions, and warnings NOTE: A NOTE indicates important information that

More information

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-16i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-001137-01 For a comprehensive list of changes to this document, see the Revision History.

More information

Serial ATA PCI RAID Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide Serial ATA PCI RAID Quick Installation Guide Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers.

More information

READ ME FIRST Windows 98/ME/2000

READ ME FIRST Windows 98/ME/2000 READ ME FIRST Windows 98/ME/2000 *DSL Equipment Installation Guide: Alcatel Speed Touch PC *Digital Subscriber Line Part Number: AlcatelPC9x02A Version 1.2-A Table of Contents Follow Steps 1 through 7

More information

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA)

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA) LSI SAS 9212-4i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA) User Guide Version 1.1 DB15-000853-01 For a comprehensive list of changes to this document, see the Revision History.

More information

Flash Image for 3200 and 8200 Series Adapters. Table of Contents

Flash Image for 3200 and 8200 Series Adapters. Table of Contents Flash Image for 3200 and 8200 Series Adapters QLogic Corporation All rights reserved Table of Contents 1 Package Contents 1.1 Update the Flash Image 2 FCoE BIOS (8200 Series only) 2.1 Supported Features

More information

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations Technical Note Revised October 2006 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Configuring the StorageWorks MSA1000 and MSA1500cs for External Boot with NetWare Considerations...3

More information

QLogic iscsi Adapter SCSI Stor Miniport Driver for Windows Server 2003/XP. Table of Contents

QLogic iscsi Adapter SCSI Stor Miniport Driver for Windows Server 2003/XP. Table of Contents QLogic iscsi Adapter SCSI Stor Miniport Driver for Windows Server 2003/XP This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. OS Support

More information

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0 Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0 Revision 1.0 February 2000 Revision History Revision Revision History Date 1.0 Initial Release 02/10/00 Intel Corporation

More information

[ Quick Start Guide ]

[ Quick Start Guide ] [ Quick Start Guide ] QUICK START GUIDE FIBRE CHANNEL SWITCH INSTALLATION z SANbox 5802V for Windows Operating Systems Purchasers of OEM products should consult with the OEM for support. Support Headquarters

More information

QLogic QLA4010/QLA4010C/QLA4050/QLA4050C/ QLA4052C/QMC4052/QLE4060C/QLE4062C iscsi Driver for Linux Kernel 2.6.x.

QLogic QLA4010/QLA4010C/QLA4050/QLA4050C/ QLA4052C/QMC4052/QLE4060C/QLE4062C iscsi Driver for Linux Kernel 2.6.x. QLogic QLA4010/QLA4010C/QLA4050/QLA4050C/ QLA4052C/QMC4052/QLE4060C/QLE4062C iscsi Driver for Linux Kernel 2.6.x This software license applies only to QLogic customers. QLogic Corporation. All rights reserved.

More information

Sound Card Installation for Windows 95/98

Sound Card Installation for Windows 95/98 Sound Card Installation for Windows 95/98 Hardware Installation 1. Shut down Windows and power down system. Unplug power cable from the system. 2. Remove screws and open system enclosure. 3. Remove static

More information

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.0 This paper describes how to implement a Fibre Channel (FC) SAN

More information

Express5800/320La System Release Notes

Express5800/320La System Release Notes System Release Notes Express5800/320La System Release Notes PN: 455-01623-003 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9201-16e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-000854-01 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

SANsurfer FC/FCoE HBA Manager. Table of Contents

SANsurfer FC/FCoE HBA Manager. Table of Contents SANsurfer FC/FCoE HBA Manager QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3. OS Support 4. Supported

More information

10GbE Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents

10GbE Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents 10GbE Converged Network Adapter NDIS Miniport Driver for Windows QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. OS Support 3. Supported Features 4. Using the Driver 4.1

More information

ADSP EZ-ICE Emulator User s Guide (For Use with VisualDSP++ Release 2.0 or Higher)

ADSP EZ-ICE Emulator User s Guide (For Use with VisualDSP++ Release 2.0 or Higher) User s Guide (For Use with VisualDSP++ Release 2.0 or Higher) First Edition, Revision 1.0, October 2002 Part Number 82-000259-01 Analog Devices, Inc. Digital Signal Processing Division One Technology Way

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

SCSI device drivers are provided for the following operating systems:

SCSI device drivers are provided for the following operating systems: This section describes how to install and configure the Dell small computer system interface (SCSI) device drivers included with your Dell PowerEdge computer system. These device drivers are designed to

More information

[ Quick Start Guide ]

[ Quick Start Guide ] [ Quick Start Guide ] QUICK START GUIDE FIBRE CHANNEL SWITCH INSTALLATION z Purchasers of OEM products should consult with the OEM for support. Please feel free to contact your QLogic-approved reseller

More information

SANsurfer FC HBA Manager. Table of Contents

SANsurfer FC HBA Manager. Table of Contents SANsurfer FC HBA Manager This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements

More information

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide March 2010 Revision History March 2010 October 2009 July 2009 Version and Date Description of Changes Updated Figure 2, LSISAS9200-8e

More information

Firmware. Update Manual for Sun-Branded Fibre Channel Adapters by Emulex

Firmware. Update Manual for Sun-Branded Fibre Channel Adapters by Emulex Firmware Update Manual for Sun-Branded Fibre Channel Adapters by Emulex Copyright 2007 Emulex Corporation. All rights reserved worldwide. No part of this document may be reproduced by any means nor translated

More information

Emulex Drivers Version 10.6 for Windows. Quick Installation Manual

Emulex Drivers Version 10.6 for Windows. Quick Installation Manual Emulex Drivers Version 10.6 for Windows Quick Installation Manual Connect Monitor Manage 2 Copyright 2003-2015 Emulex. All rights reserved worldwide. No part of this document may be reproduced by any means

More information

SANsurfer FC HBA Manager. Table of Contents

SANsurfer FC HBA Manager. Table of Contents SANsurfer FC HBA Manager This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements

More information

Serial ATA PCI RAID Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide Serial ATA PCI RAID Quick Installation Guide Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers.

More information

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1 FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept

More information

Gigabit Network Card user manual Model

Gigabit Network Card user manual Model Gigabit PCI Network Card user manual Model 522328 INT-522328-UM-0108-01 Thank you for purchasing the INTELLINET NETWORK SOLUTIONS Gigabit PCI Network Card, Model 522328. A high-performance network adapter

More information

HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RWFNF-TE Fourteenth edition: April 2009

More information

EMC Fibre Channel with QLogic Host Bus Adapters in the Windows Environment

EMC Fibre Channel with QLogic Host Bus Adapters in the Windows Environment EMC Fibre Channel with QLogic Host Bus Adapters in the Windows Environment P/N 300-001-164 REV A07 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright

More information

READ ME FIRST Windows 95/98/Me/2000

READ ME FIRST Windows 95/98/Me/2000 READ ME FIRST Windows 95/98/Me/2000 *DSL Equipment Installation Guide: Efficient Networks 5260 *Digital Subscriber Line Part Number: 52609x02 Version 1.2-A Table of Contents Follow Steps 1 through 8 to

More information

RAID Controller Installation Guide

RAID Controller Installation Guide RAID Controller Installation Guide Document Number 60001075 Second Edition March 2003 The RAID Controller Installation Guide explains how to install and configure a RAID Controller in an Omvia Media Server.

More information

SANsurfer iscsi Host Bus Adapter CLI. Table of Contents

SANsurfer iscsi Host Bus Adapter CLI. Table of Contents SANsurfer iscsi Host Bus Adapter CLI QLogic Corporation All rights reserved Table of Contents 1 Package Contents 2 Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3 OS Support 4 Supported

More information

Installation and Hardware Guide. AAA-130 Series. PCI-to-Wide UltraSCSI Array Adapters

Installation and Hardware Guide. AAA-130 Series. PCI-to-Wide UltraSCSI Array Adapters Installation and Hardware Guide AAA-130 Series PCI-to-Wide UltraSCSI Array Adapters R Stock Number: 511198-00, Rev. A Page: Front Cover R Adaptec, Inc. 691 South Milpitas Boulevard Milpitas, CA 95035 1997

More information

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005) MSA1500cs ReleaseNotes hp StorageWorks Modular Smart Array 1500 cs Release Notes Third Edition (February 2005) Publication of the third edition of this document coincides with the release of MSA1500 cs

More information

READ ME FIRST Windows 95/98/Me/2000

READ ME FIRST Windows 95/98/Me/2000 READ ME FIRST Windows 95/98/Me/2000 *DSL Equipment Installation Guide: Efficient Networks 5260 *Digital Subscriber Line Part Number: 52609X02 Version 1.2 Table of Contents Follow Steps 1 through 8 to complete

More information

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260 READ ME FIRST Windows NT *DSL Equipment Installation Guide: Efficient Networks 5260 *Digital Subscriber Line Part Number: 5260NT02A Version 1.2-A. Table of Contents Follow Steps 1 through 8 to complete

More information

Port PCI Quick Installation Guide

Port PCI Quick Installation Guide 1394 3-Port PCI Quick Installation Guide Introducing the 1394 3-Port PCI The 1394 3-Port PCI is designed to connect DV camcorders, hard disk drives, scanners, printers and other 1394 audio/video devices

More information

Installation Guide AHA -1530P/1532P. Plug and Play AT-to-SCSI Host Adapter with SCSISelect Utility

Installation Guide AHA -1530P/1532P. Plug and Play AT-to-SCSI Host Adapter with SCSISelect Utility R Installation Guide AHA -1530P/1532P Plug and Play AT-to-SCSI Host Adapter with SCSISelect Utility Note: Read the AHA-1530P/1532P Getting Started guide first when you are ready to install your AHA-1530P/1532P

More information

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Integrated Mirroring SAS User s Guide Areas Covered Before Reading This Manual Chapter 1 Chapter 2 Chapter 3 This section explains the notes for your safety and conventions used in this manual. Overview

More information

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide Part number: 5697-5263 First edition: May 2005 Legal and notice information Copyright

More information

TESLA C2050 COMPUTING SYSTEM

TESLA C2050 COMPUTING SYSTEM TESLA C2050 COMPUTING SYSTEM installation guide TESLA C2050 installation guide NVIDIA Tesla C2050 Table of Contents Table of Contents Introduction 1 About This Guide 1 Minimum System Requirements 2 Unpacking

More information

DP SATA 6Gb/s 2S1P PCIe Installation Guide

DP SATA 6Gb/s 2S1P PCIe Installation Guide Introduction DP SATA 6Gb/s 2S1P PCIe Installation Guide The DP SATA 6Gb/s 2S1P PCIe will add 2 SATA 6Gb/s & a PATA connectors to PCIe-equipped computers. Features and Benefits Adds two SATA 6Gb/s and one

More information

Emulex Drivers for Linux for LightPulse Adapters Release Notes

Emulex Drivers for Linux for LightPulse Adapters Release Notes Emulex Drivers for Linux for LightPulse Adapters Release Notes Versions: FC Version 11.4.142.21 Date: September 6, 2017 Purpose and Contact Information These release notes describe the new features, current

More information

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: 8/28/2007 IBM System Storage DS3000 series Interoperability Matrix

More information

Parallels Virtuozzo Containers 4.6 for Windows

Parallels Virtuozzo Containers 4.6 for Windows Parallels Parallels Virtuozzo Containers 4.6 for Windows Deploying Microsoft Clusters Copyright 1999-2010 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels Holdings, Ltd. c/o

More information

Installation Guide AHA-2930B. PCI-to-Fast SCSI Host Adapter with SCSISelect

Installation Guide AHA-2930B. PCI-to-Fast SCSI Host Adapter with SCSISelect R Installation Guide AHA-2930B Adaptec, Inc. 691 South Milpitas Blvd. Milpitas, CA 95035 Copyright 1996, 1997, Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in

More information

JUNE 2000 IC136C. USB Card

JUNE 2000 IC136C. USB Card USB Card JUNE 2000 IC136C CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500

More information

SATA 150 PCI Card 2-Channel

SATA 150 PCI Card 2-Channel SATA 150 PCI Card 2-Channel User Manual Ver. 1.00 All brand names and trademarks are properties of their Respective owners. 1 Features Silicon Image SiI3512 SATA controller chip Compliant with PCI Specification,

More information

SANblade 2200 Series User s Guide

SANblade 2200 Series User s Guide Q Simplify SANblade 22 Series User s Guide 1-Gb Fibre Channel to cpci and SBus Host Bus Adapters CF225112- C Page i SANblade 22 Series User s Guide 1-Gb Fibre Channel to cpci and SBus Host Bus Adapters

More information

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix - 1 - IBM System Storage DS3000 series Interoperability Matrix Last Revised: 9/19/2007 IBM System Storage DS3000 series Interoperability Matrix

More information

Rocket 133/133S/133SB User s Manual. Revision: 1.1 Date: Dec HighPoint Technologies, Inc.

Rocket 133/133S/133SB User s Manual. Revision: 1.1 Date: Dec HighPoint Technologies, Inc. Rocket 133/133S/133SB User s Manual Revision: 1.1 Date: Dec. 2001 HighPoint Technologies, Inc. Copyright Copyright 2001 HighPoint Technologies, Inc.. This document contains materials protected by International

More information