MCX402DR-BRD I/O expander. Operating Manual

Size: px
Start display at page:

Download "MCX402DR-BRD I/O expander. Operating Manual"

Transcription

1 Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: Document version: Rev. B

2 Design and application The MCX402DR-BRD is I/O expander dedicated to the RACS 5 system. The device is connected to MC16 access controller to provide control of 1 or 2 doors with Wiegand or PRT (RACS CLK/DTA) readers but in case of PRT readers new firmware must be uploaded to the expander. The expander offers eight NO/NC inputs, two relay outputs, two transistor outputs, 1.0A main power supply output and 0.2 auxiliary power supply output. All outputs of the expander are protected against overload. MCX402DR-BRD is supplied from 18VAC and it offers 13.8VDC at AUX and TML outputs to supply all door devices including door lock and readers. The expander can be equipped with backup battery. The expander is offered individually as electronic module or as a component of MCX402-1-KIT for readin/out door control or as a component of MCX402-2-KIT for two read-in doors control. In case of upgrade from RACS 4 to RACS 5 system, PR411 and PR402 controllers can be converted into MCX402DR expanders by upload of new firmware. Characteristics RS485 interface for communication with MC16 access controller Wiegand 26-66bit interface for communication with two readers of third party RACS CLK/DTA interface for communication with two PRT series readers 8 inputs NO/NC Relay output NO/NC 1,5A/30V Relay output NO/NC 5A/230VAC 2 transistor outputs 1A/15VDC Power output 13.8VDC/1.0A Power output 13.8VDC/0.2A 18VAC, 12VDC or 24VDC power supply Battery charging with 0.3A current Protection against full battery discharge Reporting of power supply status to access controller Fig. 1 General concept of MCX402DR-BRD application 2/11

3 Fig. 2 MCX402DR-BRD application in single read-in/out door control (A) and two read-in doors control (B) Power supply and backup battery MCX402DR-BRD expander is designed for power supply from 230VAC/18VAC/40VA transformer and then it offers 13.8VDC power outputs (AUX, TML) for external devices. Optionally the expander can be supplied from 12VDC or 24VDC but in case of 12VDC the backup battery cannot be directly connected to the expander thus the emergency power supply must be provided by external PSU. Note: Expander cannot be started using only power supply from backup battery. Fig. 3 MCX402DR-BRD supply from 18VAC 3/11

4 Fig. 4 MCX402DR-BRD supply from 12VDC or 24VDC Connection to RS485 communication bus MCX402DR-BRD is an addressable device and it must be connected to RS485 communication bus of the controller where MCT readers and other MCX expanders are usually also operated. Prior to connection, the expander must be assigned unoccupied address in range of Any topology of communication bus can be used (e.g. star, tree). The matching resistors (terminators) connected at the ends of transmitting lines are not required. In most cases communication works with any signal cable e.g. U/UTP cat.5. All devices connected to the same bus should have GND terminals connected. The RS485 communication standard in RACS 5 system guarantees proper communication in a distance of up to 1200 meters as well as high resistance to interferences. IN1-IN8 inputs The expander offers 8 inputs IN1-IN8 which can be configured as NO or NC. Electric parameters of all inputs are configured within low level configuration by means of RogerVDM software. Inputs are assigned with functions using VISO management software. IO1 and IO2 outputs The expander offers two open collector type transistor outputs IO1 and IO2. Output polarity can be configured as normal or reversed. Output with normal polarity represents high impedance in normal state and is shorted to ground when triggered. Output with reversed polarity operates with inverted logic. It is shorted to ground in normal state and represents high impedance when triggered. The configuration of output polarity is done within low level configuration using RogerVDM software. By default, outputs are configured with normal polarity. Outputs are assigned with functions using VISO management software. REL1 and REL2 outputs The expander offers two relay outputs REL1 and REL2. Each relay offers NO/NC terminals and REL1 is 30V/1.5A rated while REL2 is 230VAC/5A rated. In case of power outage both relays remain in the off state. Outputs are assigned with functions using VISO management software. AUX power output AUX power supply output is dedicated to supply door lock, alarm signalling device and other door related devices. The terminal AUX is protected with 1.0A electronic fuse. TML power output TML power supply output is dedicated to supply readers at doors. The terminal TML+ is protected with 0.2A electronic fuse. Door control The expander offers power supply at door and enables the operation of PRT (RACS CLK/DTA) or Wiegand readers with MC16 access controller. The expander offers 1.0A power output (AUX), 0.2A power output (TML), RACS CLK/DTA communication bus and programmable inputs/outputs which can be used to control door lock, communication with Wiegand readers and control of LEDs and buzzer of Wiegand readers. The 1.0A output is dedicated to supply door lock and door related devices (e.g. alarm signalling device). The 4/11

5 0.2A output is dedicated to supply readers. In the figure below a typical read-in/read-out door control scenario with MCX402DR-BRD expander is presented. The door system is supplied from the expander and it includes: 2 x PRT (RACS CLK/DTA) or 2 x Wiegand 26-66bit readers 12VDC door lock 12VDC alarm signalling device Door contact Exit button Fig. 5 Typical scenario of operation for read-in/read-out door with PRT readers (A) and Wiegand readers (B) Connection of expander to controller The expander is not operated as standalone device but as an extension of MC16 access controller. It is recommended to supply the MCX402DR-BRD from own transformer and equip it with backup battery. All devices connected to the same RS485 bus should have GND terminals connected. Such connection can be ensured with any wire. The maximal length of RS485 bus between MC16 controller and the expander equals to 1200m. MCX402-BRD expander is usually installed near controlled door. Fig. 6 Connection diagram for MC16 controller and expander 5/11

6 Device configuration The expander is configured within low level configuration by means of RogerVDM software. Such configuration must be done prior to connection to MC16 access controller particularly in regard of RS485 address and reader parameters. The address of expander can also be programmed manually with jumpers on expander s board. The address programmed with jumpers (hardware address) has higher priority than the address programmed with RogerVDM (software address). The factory new expander has ID=100 software address. Addressing with jumpers Every time the address is modified, the expander must be restarted with RST button or switching power supply off and on. Fig. 7 Manual addressing with jumpers on expander s board Low level configuration with RogerVDM software Fig. 8 Connection of expander to RUD-1 interface Connect the expander to RUD-1 interface as indicated in Fig.8. Run RogerVDM program and select MCX v1.x device, firmware version, RS485 communication channel and communication port (COM) emulated by RUD-1 interface. Click Connect and program will display main configuration window with parameters read from the connected device. 6/11

7 Set device address ( ) and other configuration parameters. Click Send to device to upload modified configuration parameters to the connected device. Optionally, save configuration parameters to file using Save to file button. Disconnect programmed device from RUD-1 interface. When low level configuration is finished then the expander can be connected to access controller in order to make functional configuration with VISO management software. Configuration parameters In the table below the configuration parameters of MCX402DR-BRD expander are presented. All settings are programmed with RogerVDM software within low level configuration of the expander. Configuration parameters Parameter Function Communication settings RS485 Address Parameter defines device address on RS485 bus. Range: Default value: 100 RS485 communication timeout [s] Parameter defines delay after which device will signal lost communication with controller. Range: 0-64s. When set to 0 then signalling is disabled. Default value: 10 s. General Single key press** When option is enabled then reader transmits the whole PIN to controller. When option is disabled then reader transmits every pressed key separately. Range: Yes, No. Default value: Yes. Min. PIN length Parameter defines minimal number of digits in PIN. Range: 0-8. When set to 0 then PIN is disabled. Default value: 4. Max. PIN length Parameter defines maximal number of digits in PIN. Range 0-8. When set to 0 then PIN is disabled. Default value: 8. [*] clears PIN buffer When option is enabled then [*] key pressing clears PIN buffer. Range: Yes, No. Default value: Tak Time between keys in PIN [s] PIN followed by [#] key AC return timeout [min.] AC lost delay [min.] Parameter defines max. time between two consecutive key pressings. Range: Default value: 20. When option is enabled then PIN must be followed with [#] key. Range: Yes, No. Default value: Yes. Parameter defines time after which return of AC supply is reported. Range: When set to 0 then signalling is disabled. Default value: 2. Parameter defines time after which loss of AC supply is reported. Range: When set to 0 then signalling is disabled. Default value: 10. Battery test period [min.] Parameter defines time between battery tests. Range: When set to 0 then testing is disabled. Default value: 10. Input types IN1-IN8 Parameter defines the type of input line. When Wiegand readers are enabled then inputs IN1-IN4 are reserved for such readers. Input comments IN1-IN8 Parameter defines any text or comment which corresponds to the object. It is later displayed in VISO program. Output polarity 7/11

8 REL1,REL2 IO1, IO2 Output and power supply comments REL1, REL2 IO1,IO2 PWR Device comment DEV Wiegand Terminal 1/2* Terminal enabled Keypad enabled Card type Card class KBD comment CDI comment Parameter defines the polarity of output line. Output with normal polarity represents high impedance in normal state and is shorted to ground when triggered. Output with reversed polarity operates with inverted logic. It is shorted to ground in normal state and represents high impedance when triggered. Range: [0]: Normal polarity, [1]: Reversed polarity. Default value: 0 Parameter defines any text or comment which corresponds to the object. It is later displayed in VISO program. When option is enabled then Wiegand Terminal 1/2 is operated. Range: Yes, No. Default value: Yes. When option is enabled the keypad on Wiegand Terminal 1/2 is operated. Range: Yes, No. Default value: Yes. Parameter defines the data type of the card returned by terminal. Default value: [16]: Number 40bits. Parameter defines the class of the card returned by terminal. Default value: [2]: EM. Parameter defines any text or comment which corresponds to the object. It is later displayed in VISO program. Card code length Parameter defines type of Wiegand 26-66bit interface. Range: Default value: 26 Card code reverse order When the option is enabled then expected card code returned by terminals is in reverse order. Range: Yes, No. Default value: No. PIN format Parameter defines format of PIN returned by terminal. Range: [0]: None, [1]: BIN, [2]: BCD, [3]: HEX. Default value: [0]: None. PIN length PIN reverse order Single key press Terminal RACS CLK/DTA ID0/ID1** Terminal enabled Keypad enabled Card type Parameter defines the length of PIN returned by terminal. Range: Default value: 0. When option is enabled then expected PIN returned by terminal is in reverse order. Range: Yes, No. Default value: No. When option is enabled then reader transmits the whole PIN to controller. When option is disabled then reader transmits every pressed key separately. Range: Yes, No. Default value: No. When option is enabled then PRT terminal ID0/ID1 on RACS CLK/DTA bus is operated. Range: Yes, No. Default value: Yes. When option is enabled then keypad on Terminal ID0/ID1 is operated. Range: Yes, No. Default value: Yes. Parameter defines the data type of the card returned by terminal. Default value: [16]: Number 40bits. 8/11

9 Card class KBD comment CDI comment BUZZER comment LED SYSTEM comment LED OPEN comment Parameter defines the class of the card returned by terminal. Default value: [2]: EM. Parameter defines any text or comment which corresponds to the object. It is later displayed in VISO program. LED ARMED comment * Wiegand settings are available when the factory default MCX402DR-WGx.hex firmware is uploaded into expander ** PRT readers settings are available when MCX402DRx.hex firmware from is uploaded into expander Memory reset Memory reset procedure restores factory default settings including ID=100 software address. Remove all connections from A, B, CLK and DTA terminals. Put jumper on 64 contact and restart device with RST button on device board or by switching supply off and on. Remove jumper from 64 contacts when LED STAT (red), LED OPN and LED SYS are ON. LED OPEN and LED SYSTEM will turn OFF and device shall restart automatically with factory default settings. Firmware update Factory new expander is equipped with a firmware dedicated to Wiegand readers. If the expander is to be operated with PRT readers then another firmware must be uploaded. Such firmware is available at Firmware update is also used in case of migration from RACS 4 to RACS 5 when PR411 and PR402 controllers are converted into MCX402DR expanders. Firmware update requires RogerISP program. Firmware update with RogerISP software Connect device to RUD-1 interface according to Fig.8. Put a jumper on FDM contacts. Restart device with RST button on device board or by switching supply off and on. Start RogerISP software. Select serial port emulated by RUD-1 interface. Select the option USB-RS485 Converter. Select firmware file (*.hex). Click Program and follow instructions on the screen. Once the firmware is uploaded remove the FDM jumper. Restart device. Start Memory Reset procedure. Installation Enclosure with DIN rail is recommended for installation of MCX402DR expander. All electric connections must be done without voltage on wires/terminals and with power supply disconnected. Optionally DIN rail mounting clips can be removed and the expander can be installed on flat surface. It is recommended to install the expander in the same enclosure as transformer/psu. Prior to expander connection to the controller specify RS485 address and configure other parameters if necessary. The expander is configured within low level configuration by means of RogerVDM. Default address of factory new device is ID=100. 9/11

10 Fig. 9 MCX402DR board MCX402DR terminals Term. Description Term. Description BAT+ Battery positive pole GND Ground BAT- Battery negative pole IN7 IN7 input line P1 Power supply input IN8 IN8 input line P2 Power supply input IO1 IO1 output line COM1 REL1 relay common terminal IO2 IO2 output line NC1 REL1 relay output (NC) IN1 IN1 input line NO1 REL1 relay output (NO) IN2 IN2 input line CLK RACS CLK/DTA interface, line CLK GND Ground DTA RACS CLK/DTA interface, line DTA IN3 IN3 input line GND Ground IN4 IN4 input line A RS485 communication bus, line A TML Power supply output 12VDC/0.2A B RS485 communication bus, line B AUX Power supply output 12VDC/1.0A GND Ground NO2 REL2 relay output (NO) IN5 IN5 input line NC2 REL2 relay output (NC) IN6 IN6 input line COM2 REL2 relay common terminal Specification Supply voltage Backup battery Average current consumption Nominal 18VAC, min./max. range 17-22VAC Nominal 12VDC, min./max. range 10-15VDC Nominal 24VDC, min./max. range 22-26VDC 13.8V/7Ah, charging current app. 300mA 100 ma (excluding load points connected to AUX and/or TML outputs) 10/11

11 Inputs Relay outputs Transistor outputs Power supply outputs Distances Environmental class Dimensions Weight Certificates Eight (IN1-IN8) NO/NC inputs, electrically biased to +12V via 15kΩ resistor, triggering level app. 3.5V Two (REL1,REL2) relay outputs with single NO/NC contact, 30V/1.5A (REL1) and 230VAC/5A (REL2) rated Two (IO1,IO2) open collector outputs, 15VDC/1A rated Two power supply outputs: 12VDC/0.2A (TML) and 12VDC/1A (AUX) rated Between controller and expander (RS485): max. 1200m Between expander and Wiegand reader: max. 100 m Between expander and PRT reader (RACS CLK/DTA): max. 150 m Class I, indoor general conditions, temperature: +5 C to +40 C, relative humidity: 10 to 95% (no condensation) 80 x 115 x 28mm approx. 100g CE Ordering information Product MCX402DR-BRD MCX402-1-KIT MCX402-2-KIT Description I/O expander for door control with Wiegand or PRT readers 1-door expander kit 2-door expander kit Product history Version Date Description MCX402DR v1.0 10/2017 The first commercial version of the product This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health. The user is obliged to deliver equipment to the designated collection points of electric and electronic waste. For detailed information on recycling, contact your local authorities, waste disposal company or point of purchase. Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment. Weight of the equipment is specified in the document. Contact: Roger sp. z o.o. sp.k Sztum Gościszewo 59 Tel.: Fax: Tech. support: biuro@roger.pl Web: 11/11

Installation guide for PR602LCD type access controller

Installation guide for PR602LCD type access controller Roger Access Control System Installation guide for PR602LCD type access controller Firmware version: 1.18.6 or newer Document version: Rev. K 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document

More information

Installation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers

Installation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers Roger Access Control System Installation guide for PR612, PR622, PR312EM, PR312EM-BK, PR312MF and PR312MF-BK access controllers Firmware version: 1.18.6 or newer Document version: Rev. G 2016 ROGER sp.

More information

MCT82M-IO-CH Operating Manual

MCT82M-IO-CH Operating Manual Roger Access Control System MCT82M-IO-CH Operating Manual Product version: 1.0 Document version: Rev. B FUNCTIONAL DESCRIPTION Design and application The MCT82M-IO-CH is an access terminal dedicated to

More information

Installation guide for PR302 v2.0 Rev. E

Installation guide for PR302 v2.0 Rev. E Installation guide for PR302 v2.0 Rev. E 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document is subject to the Terms of Use in their current version published at the www.roger.pl website of

More information

PR402 v2.0 Installer Manual Rev.C

PR402 v2.0 Installer Manual Rev.C PR402 v2.0 Installer Manual Rev.C Introduction This document contents minimum information required for electrical connections, installation and initial tests of PR402 access controller. Installation The

More information

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its

More information

RFT1000 reader in RACS 5. User Manual

RFT1000 reader in RACS 5. User Manual Roger Access Control System RFT1000 reader in RACS 5 User Manual Firmware version: 1.3 or newer Hardware version: 1.1 Document version: Rev. A 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document

More information

PR602LCD v1.0 Installer Manual Rev. A

PR602LCD v1.0 Installer Manual Rev. A PR602LCD v1.0 Installer Manual Rev. A Introduction This document contents minimum information required for electrical connections and installation of the PR602LCD access controller in Roger Access Control

More information

Buffered Power Supply PS-30DR v1.0

Buffered Power Supply PS-30DR v1.0 Roger Access Control System Buffered Power Supply PS-30DR v1.0 Document version: Rev. C Firmware: 1.0.4 1. PRODUCT DESCRIPTION The PS-30DR is dedicated for electronic equipment which require 12VDC buffered

More information

PRT12MF-DES, PRT84MF and PRT82MF readers. Operating Manual

PRT12MF-DES, PRT84MF and PRT82MF readers. Operating Manual Roger Access Control System PRT12MF-DES, PRT84MF and PRT82MF readers Operating Manual Firmware version: v1.0.8 or newer Hardware version: 1.0 Document version: Rev. C This document refers to the following

More information

Installation guide for RUD-1 Communication Interface

Installation guide for RUD-1 Communication Interface Roger Access Control System Installation guide for RUD-1 Communication Interface Firmware version: n.a. Document version: Rev. D 1. DESCRIPTION AND SPECIFICATION RUD-1 is an optional, universal, portable,

More information

PRxx1 series controllers Functional Description and Programming Guide

PRxx1 series controllers Functional Description and Programming Guide Roger Access Control System PRxx1 series controllers Functional Description and Programming Guide Document version: Rev.E This document refers to the following products: PR311SE, PR311SE-BK, PR611, PR621,

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

VISO Mobile app (Android) Operating Manual

VISO Mobile app (Android) Operating Manual Roger Access Control System VISO Mobile app (Android) Operating Manual Software version: 1.4 Document version: Rev. B 1. DESCRIPTION VISO Mobile is a mobile app dedicated to control remotely the RACS 5

More information

PSBOC PSBOC 27,6V/5,5A/OC

PSBOC PSBOC 27,6V/5,5A/OC v.1.1 PSBOC 27,6V/5,5A/OC Enclosed buffer switch mode power supply unit with technical outputs. EN** Edition: 8 from 01.06.2016 Supercedes edition: 7 from 10.04.2015 Features: 27,6VDC/5,5A uninterrupted

More information

Rev B ROGER ACCESS CONTROL SYSTEM

Rev B ROGER ACCESS CONTROL SYSTEM Rev B ROGER ACCESS CONTROL SYSTEM Roger access control solutions Code Locks Readers Access Controllers CPR Network Controllers Communication Interfaces Expanders Power Supply Units Accessories 2 SL2000

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible

More information

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

PR402 v1.0 SINGLE DOOR ACCESS CONTROLLER

PR402 v1.0 SINGLE DOOR ACCESS CONTROLLER PR402 v1.0 SINGLE DOOR ACCESS CONTROLLER FIRMWARE VERSION 117.0 Installation Manual MASCO Biztonságtechnikai és Nyílászáró Automatizálási Kereskedelmi Kft. 1045 Budapest, Madridi út 2. Tel: (06 1) 3904170,

More information

Scalable Access Control System with Building Automation

Scalable Access Control System with Building Automation Guide v5.3 Rev. A Scalable Access Control System with Building Automation System Workstations system management on multiple workstations operator authentication through Active Directory landlord-tenant

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

SINGLE READER EXPANSION MODULE

SINGLE READER EXPANSION MODULE SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

PRTxxMF series ISO/IEC 14443A and MIFARE readers. Firmware version: x Document version: Rev. H. This document refers to following products:

PRTxxMF series ISO/IEC 14443A and MIFARE readers. Firmware version: x Document version: Rev. H. This document refers to following products: PRTxxMF series ISO/IEC 14443A and MIFARE readers Firmware version: x.35.164 Document version: Rev. H This document refers to following products: - PRT12MF - PRT12MF-BK - PRT62MF - PRT64MF - PRT66MF Operating

More information

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras Edition: 4 from 15.11.2017 Supercedes the edition: 3 from 30.03.2017 EN** Features: Uninterruptible power supply

More information

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras Edition: 3 from 07.03.2018 Supercedes the edition: 2 from 15.11.2017 EN** Features: Uninterruptible power

More information

PRT12 v1.2 RFID/PIN Outdoor Access Terminal

PRT12 v1.2 RFID/PIN Outdoor Access Terminal PRT12 v1.2 RFID/PIN Outdoor Access Terminal Firmware v73.00 Installation and Programming Guide MASCO Biztonságtechnikai és Nyílászáró Automatizálási Kereskedelmi Kft. 1045 Budapest, Madridi út 2. Tel:

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

DIN-RAIL EXPANDER int-iors_en 10/14

DIN-RAIL EXPANDER int-iors_en 10/14 INT-IORS INT-ORS DIN-RAIL EXPANDER int-iors_en 10/14 The INT-IORS expander enables the system to be expanded by 8 programmable wired zones and 8 programmable wired outputs. The INT-ORS expander enables

More information

SPX-7400_SPX-7410_MAN_161028

SPX-7400_SPX-7410_MAN_161028 Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Installation and Programming Guide

Installation and Programming Guide PRT-EM Series EM 125 khz Access Terminals Firmware v1.29 and v2.29 Rev. K This document refers to the following products: - PRT12EM - PRT12EM-BK - PRT32EM - PRT42EM - PRT42EM-BK - PRT62EM - PRT64EM - PRT64EM-VP

More information

1. Product Specification

1. Product Specification 1. Product Specification Item Specification Voltage 12VDC +10%, Current 1.2A Lock Relay 12VDC/2A Environmental Temperature working:0 ~45 ; storage:-10 ~55 Relative humidity working:40%~90%rh; Card Capacity

More information

VISO WEB Server Application. Operating manual

VISO WEB Server Application. Operating manual Roger Access Control System VISO WEB Server Application Operating manual Software version: 1.4.2 Document version: Rev. C 1. DESCRIPTION VISO WEB is a network application which enables RACS 5 system management

More information

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control D1551A D1551B D1551P D1553B D1553C D1553P D1555B D1555C D1555P D155X Series Part Numbers 1A 12 volts in A box 1A

More information

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives with Electronic (E) Bypass Options SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

PRT42 and PRT42-BK Indoor Access Control Terminals Firmware v72.00

PRT42 and PRT42-BK Indoor Access Control Terminals Firmware v72.00 PRT42 and PRT42-BK Indoor Access Control Terminals Firmware v72.00 Installation and Programming Guide MASCO Biztonságtechnikai és Nyílászáró Automatizálási Kereskedelmi Kft. 1045 Budapest, Madridi út 2.

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815 95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing

More information

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811 95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3 KOD: TYP: PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU EN BLACK POWER This product is suitable for the systems designed in compliance with the PN-EN 50131-6 grade 1, 2 or 3

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

RFID/Digital Access Control Keypad

RFID/Digital Access Control Keypad R Luminous/ RFID/Digital Access Control Keypad Model:YK-368L-R Germany EMC tested FEATURES AND FUNCTIONS Simple Programming, Easy Operation 3-Operation Mode: ID Card Operation, User Code Operation, ID

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

1. Features. 2. Installation KNX INTEGRATION MODULE INT-KNX

1. Features. 2. Installation KNX INTEGRATION MODULE INT-KNX KNX INTEGRATION MODULE INT-KNX int-knx_en 09/11 The INT-KNX module integrates the INTEGRA alarm system with the KNX system, so the control panel can control the actuators connected to the KNX bus, and

More information

Installation / Setup Manual

Installation / Setup Manual April, 2008 Cat Series 4 Entrance Expansion Module Installation / Setup Manual CATD4 Select Engineered Systems, Inc. Page 1 CAT Series Auxiliary 4 eader Module This page left intentionally blank Page 2

More information

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default

More information

HI SEC Integrated Systems

HI SEC Integrated Systems Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT

More information

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from BNC08128C v.1.0 BNC 13,8V/8x1A/17Ah Switch mode buffer power supply unit for CCTV. EN** Edition: 3 from 15.05.2014 Supersedes the edition: 2 from 25.03.2014 GREEN POWER CCTV BNC PSU features: DC 13,8V/8x1A

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

PRT62 v1.1 Outdoor Access Control Terminal Firmware v74.7

PRT62 v1.1 Outdoor Access Control Terminal Firmware v74.7 PRT62 v1.1 Outdoor Access Control Terminal Firmware v74.7 Installation and Programming Guide 1 T ABLE OF C ONTENTS 1 Table of Contents...2 2 General...3 2.1 Designed Function...3 2.2 Features...3 3 Operating

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /

More information

DORMA. Installation Manual Extension kit I/O module in the B6L 4P

DORMA. Installation Manual Extension kit I/O module in the B6L 4P DORMA Installation Manual Extension kit I/O module in the B6L 4P Contents Contents 1 General information......................... 3 1.1 Preface................................. 3 1.2 Correct use.............................

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

PRT-PX16 16 PGM Output Expander

PRT-PX16 16 PGM Output Expander PRT-PX16 16 PGM Output Expander Installation Manual CONTENTS Protégé System Introduction... PGM Expander... Features... PGM Expander Specifications... Protégé System Management Suite... Protégé Modules...

More information

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316 CYPRESS Suprex RF Series Operations Manual Suprex Reader Extender - RF Wireless Interface EXP-2000 SPX-5521 900 Mhz SPX-5521_MAN_0316 Cypress Suprex SPX-5521 Series Overview This manual covers the operation

More information

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3. Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200

More information

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1 USER S MANUAL VER.1 C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1 MARCH 2018 User s Manual Page i USER'S MANUAL TABLE OF CONTENTS Contents Page # 1.0 OVERVIEW... iii 2.0 FEATURES... iii 3.0 SPECIFICATIONS...

More information

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz SPX-5000 Series Operations Manual Suprex Reader Extender - RF Wireless Interface SPX-5601 2.4GHz RPT-5651 2.4GHz Repeater SPX-5521 900 Mhz IOX-7621 2.4GHz EXP-2000 SPX-6601 2.4GHz SPX-5000_MAN_082112 This

More information

EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems

EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems CODE: TYPE: EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems EN** RED POWER 1438 Certificate of constancy of performance CNBOP-PIB No 1438-CPR-0385 Certificate of admittance

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,

More information

Remote management of RACS 5

Remote management of RACS 5 R o g e r A c c e s s C o n t r o l S y s t e m 5 Application note no. 035 Document version: Rev. B Remote management of RACS 5 system Note: This document refers to RACS v5.5 (VISO 1.5.2 or higher) Introduction

More information

UNIVERSAL CURRENT CONVERTER

UNIVERSAL CURRENT CONVERTER UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the

More information

ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM ACCESS CONTROL SYSTEM System versions Standalone controllers series based on integrated models KZ-400, 500, 600, 700, KZC-300,800, 900 KaDe Lite system based on integrated controllers KZ-1000 KaDe Premium

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power

More information

Serial Data DIN Fiber Link System

Serial Data DIN Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-120 2017A-0420 DIN Fiber Link System COMPACT, RUGGED & TEMPERATURE HARDENED Introduction The DIN Fiber Link system transports

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3 CODE: TYPE: PSBEN 5024C EN** v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit BLACK POWER Functional requirements This product is suitable for the systems designed in compliance

More information

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Key Switch. Document version: 1.5 (Updated 02 May 2017) Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3 CODE: TYPE: EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. BLACK POWER H H 1 W W 1 D 1 D Functional requirements This product is suitable for the systems

More information