Nanodyne Replacement Illuminator for Zeiss Axiovert Microscope Installation Instructions
|
|
- Tabitha McBride
- 5 years ago
- Views:
Transcription
1 Nanodyne Replacement Illuminator for Zeiss xiovert Microscope Installation Instructions Note that this photo shows an older version of the illuminator. The current version is shown on the sheet. Original Zeiss xiovert Illuminator Nanodyne Replacement Illuminator for Zeiss xiovert Copyright 09 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Wayne onin Wayne onin //09 PN 0760 Zeiss xiovert OF 6
2 Nanodyne Replacement Illuminator for Zeiss xiovert Microscope Installation Instructions - Included Items dditional Items Included ut Not Shown: PN 090 Hex Key 5/6 inch for set screw PN 098 TPI Main ssy with Lens - Top djust PN 07 Power Supply - XP Power 5V Fixed lade US Input/US Output and PN 07 Cable ssy.5mm ID x.5mm OD R plug to US, 6 foot. The illuminator may be powered by plugging the cable into the power supply provided, or into a suitable US port on a computer or other device. PN 067 rass Tip Set Screw 8- Power supplies are subject to substitution without notice due to availability issues and changes in regulations. PN 0756 Zeiss xiovert Mounting Ring Copyright 09 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Wayne onin Wayne onin //09 PN 0760 Zeiss xiovert OF 6
3 Nanodyne Replacement Illuminator for Zeiss xiovert Microscope Installation Instructions - Step. Remove old lamp housing. Photo a Remove the lamp housing by twisting counter clock wise and pulling it off. Note the three screws holding the lamp/condenser lens assembly in place. Photo b Do Not Remove the rm From the Microscope. It is shown that way only because that is all we had access to. Copyright 09 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Wayne onin Wayne onin //09 PN 0760 Zeiss xiovert OF 6
4 Nanodyne Replacement Illuminator for Zeiss xiovert Microscope Installation Instructions - Step. Remove old lamp/condenser lens assembly and wires. Photo a Photo b Remove the three screws holding the lamp/condenser lens assembly. Retain the three screws and the filter holder as they will be used with the new illuminator. Cut the power leads to the old lamp as shown above. Either insulate the end of the wires remaining in the microscope, or completely remove the wire and/or original power supply so there is no possibility of power being applied to the old wiring. Copyright 09 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Wayne onin Wayne onin //09 PN 0760 Zeiss xiovert OF 6
5 Nanodyne Replacement Illuminator for Zeiss xiovert Microscope Installation Instructions - Step. Re-install filter holder. Photo b Replace the filter holder in its original position as shown above. Photo a Pull the illuminator assembly free from the arm as shown above. It is no longer needed. Copyright 09 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Wayne onin Wayne onin //09 PN 0760 Zeiss xiovert 5 OF 6
6 Nanodyne Replacement Illuminator for Zeiss xiovert Microscope Installation Instructions - Step. ttach Nanodyne adapter and illuminator. Photo a Using the three screws from the original illuminator, attach PN 0756 adapter ring as shown above. lthough not visible above, the brass tip set screw should be visible but not protruding into the inner diameter of the adapter ring. Note that this photo shows an older version of the illuminator. The current version is shown on the sheet. Insert PN 0759 Illuminator ssembly into the adapter ring and secure in place using the 5/6 hex key to tighten the set screw. fter attaching the power supply, the unit is ready to operate. To avoid confusion it would be good to black out the "6V 5W / 0W" text from the original illuminator with a permanent marker. Copyright 09 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. Wayne onin Photo b Wayne onin //09 PN 0760 Zeiss xiovert 6 OF 6
Original Zeiss Axiovert Illuminator. Nanodyne Replacement Illuminator for Zeiss Axiovert
Zeiss xiovert Replacement Instructions - Original and Nanodyne Replacement Original Zeiss xiovert Illuminator Nanodyne Replacement Illuminator for Zeiss xiovert Copyright 06 Nanodyne Measurement Systems.
More informationMicroscope with original illuminator. Microscope with Nanodyne replacement illuminator.
Nanodyne Replacement Illuminator for Zeiss xioskop Microscope Microscope with original illuminator. Microscope with Nanodyne replacement illuminator. Copyright 09 Nanodyne Measurement Systems. Document
More informationOlympus BX43_46 Installation Instruction (OEM Adjust) 4
Olympus X_6 Installation Instruction (OEM djust) If you are not an experienced repair tech please consider the alternate (easy install) version dditional Items Included ut Not Shown: PN 07 Olympus X Illuminator
More informationOlympus BX43 and BX46 Installation Instruction for Microscope End Users (easy install version) 4
Olympus X and X6 Installation Instruction for Microscope End Users (easy install version) PN 07 Olympus X_6 Illuminator ssy dditional Items Included ut Not Shown: PN 077 Hex Key mm PN 060 Hex Key mm M
More informationIncluded Items Not Shown:
PN 09 HP Illuminator ssy Olympus HS Installation Instructions - Nanodyne Illuminator for Olympus HS Microscope Figure. Parts included in Olympus HS Illuminator System. Included Items Not Shown: PN 057.5mm
More informationBPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
BPL SERIES INSTALLATION INSTRUCTIONS Important Warning THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This product must be installed in accordance with National Electrical
More informationCONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS
CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models L-100, M-100 Series, M-l, M-2, M-3 LESLIE Speaker Models 760, 770, 825 KIT CONTENT Console Connector Assembly 043075
More information1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.
CONSOLE CONNECTOR KIT 8101 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models A-100, D-100, RT2, RT3 LESLIE Speaker Models 122, 122RV KIT CONTENT Console Connector Assembly 047357 Echo Control
More informationArecont Vision MegaDome Installation Manual
0 P age MegaDome Installation Manual. recont Vision MegaDome B. Mounting template C. Magnetic core D. Pack of four (4) wood screws and four (4) dry wall anchors E. One double sided hex key F. One single
More informationArecont Vision MegaDome TM Installation Manual
0 P age MegaDome Installation Manual. recont Vision MegaDome TM B. Mounting template C. Magnetic core D. Pack of four (4) wood screws and four (4) dry wall anchors E. One double sided hex key F. One single
More informationSetup Guide. Confirming the Installation Space. Installation space (W x D x H) 70.5 x 66.3 x 61.5 inches (1790 x 1684 x 1560 mm) 23.
Introductory Information Setup Guide ENGLISH Read this manual before attempting to operate the printer. Keep this manual in a handy location for future reference. Caution Instructions in this Setup Guide
More informationMicroscope. Dual Magnification Microscope 20X / 40X. Base: 115 x 180mm Net weight: 4.0kg. Stereo Zoom Microscope 7X to 45X
Dual Magnification Microscope XTJ6000-B1 Magnification: 10X/20X, 10X/30X, 20X/40X Objective: 1X/2X, 1X/3X, 2X/4X Working distance: XTJ6012: 110mm, XTJ6013: 102mm, XTJ6024: 90mm Illuminator: 8W fluorescent
More informationHeathkit HR-1680 PC Card Extender. Heathkit HR-1680 PC Assembly Extender Assembly
Heathkit HR-1680 PC Assembly Extender Assembly Version Date Author Comment 1.0 August 15, 2009 RM Groh Original draft Table of Contents Introduction...1 Heathkit s Approach...2 Parts Required...3 Assembly
More informationZ-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly
Replacing the LCD Cable To remove and replace the LCD Cable you will need the following tools: #2 Phillips screwdriver (magnetic tip preferred) Socket wrench with 10mm socket Removing the Side Panel 1.
More information* * Agilent Power Distribution Unit (PDU) Installation Guide
Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The
More informationCAMERA ASSEMBLY. Removal/Replacement of the Camera Box Assembly APR-CA. Install Camera Assembly. Remove Camera Assembly
CAMERA ASSEMBLY Removal/Replacement of the Camera Box Assembly APR-CA REQUIRED TOOLS: 9/64 hex key Small flat-tip screwdriver Remove Camera Assembly camera 1. Locate the camera assembly underneath the
More informationParts List: Part # Tools List: Instructions:
Parts List: Part # 1 pair of Dayton Audio B652s 300-652 1 Dayton Audio DTA-2 amplifier 300-385 1 MP3 module 320-350 1 7805 +5 VDC voltage regulator 7805 1 12 VDC 2A power supply 129-077 1 2.1 mm panel
More informationCONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.
Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit
More informationArecont Vision MegaDome 2 Installation Manual (DN Models Only)
recont Vision MegaDome 2 Installation Manual (DN Models Only) 0 P age recont Vision MegaDome 2 Installation Manual (DN Models Only) MegaDome 2 Installation Manual (DN Models Only). recont Vision MegaDome
More informationDisplay Lights. Display Lights. SLC30-IPS Series: 1.18" (30mm) SLC30-IPS Series Panel Mounted Annunciators
S30-IPS Series: 1.18" (30mm) S30-IPS Series Panel Mounted Annunciators The S30-IPS combination display lights with control units combine display lights with control units such as pushbuttons, illuminated
More informationM20 Metallurgical Microscope User s Manual. Fein.
M20 Metallurgical Microscope User s Manual info@feinoptic.com M20 Microscope Components Lamp Housing C-Mount Adapter Eyepieces Analyzer Objective Lens Coarse Focus Mechanical Stage Stage X-Y Control Fine
More informationPreparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management
Docking Drawer Install Manual Docking Drawer Slim Series Applicable Models: 0290 00031(W) / 24 0290-00030(W) / 21 0290-00047(W) / 18 0230-00004. r6 1/19/2016 CAUTION READ CAREFULLY Failure to follow these
More informationUSBCNC USB Disk Key reader for CNC Controls Machine Mount instructions
USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions 2008-2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla St. Chatsworth, CA 91311 www.calmotion.com Introduction This
More information9100 Series. Card Edge Fixture Kit. P/N September , John Fluke Mfg. Co., Inc. All rights reserved. Litho in U.S.A.
9100 Series Card Edge Fixture Kit P/N 830349 September 1987 1987, John Fluke Mfg. Co., Inc. All rights reserved. Litho in U.S.A. CONTENTS Section Title Page 1. Introduction......................................
More informationUpgrade Instructions. P/N Revision A. October Printer Terminal Holder * *
Upgrade Instructions P/N 96-08-0 Revision A October 000 480 Printer Terminal Holder P/N 96-08-0 Revision A *96080* Instructions This terminal holder connects the INTERMEC R 600 Series and 700 Series Computers
More informationDescription: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447
Procedure: BRAKE BUSHING REPLACEMENT PROCEDURE Product: Document #: Rev: Page: MODEL 7000, 7000A, & 8000 GYRO 078 1 1 of 14 Description: Detailed procedure on removing old bushing and installing new Brake
More informationConstructing a Newtonian Achromatic Refracting Telescope Dr. Larry Browning, SDSU Physics Department
Constructing a Newtonian Achromatic Refracting Telescope Dr. Larry Browning, SDSU Physics Department These are plans to construct a Newtonian achromatic refractor telescope with a 70-mm aperture and an
More informationWARNING SPECIAL HANDLING REQUIRED!!!
WRNING SPECIL HNDLING REQUIRED!!! Electrostatic Discharge (ESD) Information Electrostatic discharge, the uncontrolled release of static electricity, can damage electronic parts and assemblies. ESD occurs
More informationUHP-T-LED User Manual
UHP-T-LED User Manual Ver 03 July 2014 UHP-T-LED System Description The UHP-T-LED is an Ultra High Power LED light source for fluorescence microscopy, Optogenetics, High power illumination and other applications.
More informationRING LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED
R80 Series RING LIGHT product introduction The all metal construction of the Series of lights provides a small particle resistant and all around durable light. Its simple plug and play 5 Pin M12 connector
More informationMi50 Inverted Microscope User s Manual. Fein.
Mi50 Inverted Microscope User s Manual Fein info@feinoptic.com Mi50 Microscope Components Siedentopf Trinocular Head Stage Plate Mechanical Stage Locking Screw Hex Wrench Storage Beam Splitter Dust Protector
More informationCAUTION READ CAREFULLY
DOCKING DRAWER INSTALL MANUAL, 0230-00004 Rev 2 7/1/15 Applicable Models: 0290-00030, 0290-00031 JTech Solutions, Inc. 12893 Alcosta Blvd. Ste M San Ramon, CA 94583 www.jtechsolutions.us CAUTION READ CAREFULLY
More informationShadowLESS lighting systems for microscopy
ShadowLESS lighting systems for microscopy Brightfield illumination (BF) BF-5400 BF-6500 Darkfield illumination (DF) DF-5400 DF-6500 INSTRUCTION MANUAL CONTENTS A. GENERAL INSTRUCTIONS 1 A1. Safety instructions
More informationLANCNC FTP Data Server for CNC Controls Machine Mount instructions
LANCNC FTP Data Server for CNC Controls Machine Mount instructions 2008-2016 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationIS-DM220/IR/HB IS-DM220
IS-DM220/IR/HB IS-DM220 Installation Guide Indoor/Outdoor Ver. 1.2 00P6NX223ZXSEA2 Table of Contents 1. Indoor Camera Installation... 3 1.1 Hard Ceiling... 3 1.2 In-Ceiling (T-Bar) Mounting... 13 1.3 4S
More informationFront View. Right Section View. Back View. Assy. Number Assy. Description A Control unit, MDU. Date 08.
18 av 94-2013-11-05 Front View Right Section View Back View 2011-10-14 Date 08 Revision Drawn KRT 6400007 Control unit, MDU 1:2 19 av 94-2013-11-05 1 Tighten lens nuts very carefully, lenses break easily
More informationNational Optical & Scientific Instruments Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)
National Optical & Scientific Instruments Inc. 6508 Tri-County Parkway Schertz, Texas 78154 Phone (210) 590-9010 Fax (210) 590-1104 INSTRUCTIONS FOR STEREOSCOPIC ZOOM MICROSCOPE MODELS 420-430PHF-10 (Binocular
More informationM40 and M40RT Series. Metallurgical Microscopes
M40 and M40RT Series Metallurgical Microscopes M40 / M40RT Metallurgical Microscope Features LWD Plan Achromat MET Infinity Corrected Objectives Part # Objective N.A. FMPLN5 FMPLN10 FMPLN20 FMPLN50 5x
More informationABM's High Resolution Mask Aligner Features:
ABM's High Resolution Mask Aligner is a very versatile instrument with interchangeable light sources which allow Near-UV (405-365 nm) as well as Mid- and Deep-UV (254 nm, 220 nm) exposures in proximity
More informationRING LIGHT. ON = Light Rest (LED inactive) OFF = LED/Light Ready Green Indicator LED
product introduction ODR130-16 Series RING LIGHT OverDrive The ODR130-16 Series ring light features an Overdrive driver with NPN or PNP signal options. The all metal construction of the Ring Light Series
More informationPalomar. Metallurgical Microscopes. Palomar Metallurgical Microscopes
Palomar Metallurgical Microscopes 1 2 3 4 Ergonomically inclined head with eyetubes at 30 places user in the best working position, creating less tension and fatigue. Interpupillary distance is adjustable
More informationUSBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version
USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311
More informationSurvival Laser SL-005PB Laser Parts Bundle Assembly & Operation Instructions
Survival Laser SL-005PB Laser Parts Bundle Assembly & Operation Instructions WARNING: READ ALL INSTRUCTIONS AND THE ENCLOSED SAFETY PRECAUTIONS BEFORE ASSEMBLY AND USE Assemble and use these parts ONLY
More informationNikon Focus Drive Manual
Nikon Focus Drive Manual PRIOR SCIENTIFIC INC., 80 RESERVOIR PARK DRIVE, ROCKLAND, MA 02370-1062 TELEPHONE 781-878-8442 FAX 781-878-8736 WWW.PRIOR.COM Table of Contents Safety Information...1 Unpacking
More informationPower Supply, 17-inch
apple imac G5 Power Supply, 17-inch Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note:
More informationUser Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com
User Manual Binocular Stereo Microscope with Boom Stand Model W42C1 Series MicroscopeNet.com Table of Contents i. Caution.. 1 ii. Care and Maintenance... 1 1. Component Illustration... 2 2. Installation...3
More informationMemory Expansion for DriveLogix Controller
Installation Instructions Memory Expansion for rivelogix ontroller!!! TTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged before performing any work
More informationLUMOTAST 25 selector switch 1-28 LUMOTAST 25 selector switch, ring nut fixing LUMOTAST 25 keylock switch 1-30 LUMOTAST 25 keylock switch 1-31
TAST General data TAST pushbutton range Illuminable pushbuttons and signal lamps. Please order lamps/leds separately. Mounting hole diameter: 6.2 mm 42 V/00 ma max. Water-jet proof IP65 Low profile Lamp
More informationTerminal Blocks - Single Row. Series A2000, LP2000 & CB2000 Single Row Terminal Blocks
Series A2000, LP2000 & C2000 Single Row Terminal A20510807WR SPECIFICATIONS Rating: A2: 30A, 300V* LP2: 30A, 150V* C2: 30A, 300V* Center Spacing: 0.375 or 3/8 (9.52mm) Wire Range: #12-22 AWG CU Screw Size:
More informationM50 and M50RT Series. Brightfield / Darkfield Metallurgical Microscopes
M50 and M50RT Series Brightfield / Darkfield Metallurgical Microscopes M50 / M50RT Brightfield / Darkfiefld Metallurgical Microscope Features Semi APO BF MET Infinity Corrected Objectives Part # Objective
More informationSeeburg JCU-DEC Kit Convert Your Seeburg DEC Wallbox Into a Jukebox
Seeburg JCU-DEC Kit Convert Your Seeburg DEC Wallbox Into a Jukebox MP3 Compact Flash Player Coin Operated or Free Play Integrated Power Amplifier Line-Out to External Amplifier Programmable Autoplay IR
More informationInstallation Guide. Retrofit Kit for USB Ready Intraoral Systems
Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the
More informationReplacement Instructions
imac G5 Inverter, 20-inch Replacement Instructions Follow the instructions in this document carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Online
More informationPLEASE NOTE: These instructions are intended to be used by a person with average mechanical and electrical skills.
ClassicLEDs is please to present their latest line in Corvette LEDs. This covers the 1975 thru 1979 Corvette. This systems does not include the Corvette... PLEASE NOTE: These instructions are intended
More informationRaven Adapter Harness
Note: Indented items indicate parts included in an assembly listed above Quantity by System Part Name/Description Part Number With Switch Box With Built-in Switches Raven Harness Adapter Kit 4100504 1
More informationRichter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models
Richter Optica info@richter-optica.com Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models Trinocular port for c-mount adapter Zoom Knob Focusing Holder Clamp Diopter adjustable eyepieces Magnification
More informationUpgrade Instructions Printer Terminal Holder
Upgrade Instructions 6820 Printer Terminal Holder Instructions Terminal Holder Installation Kit The terminal holder connects INTERMEC R computers to the 6820 Printer. Do these instructions, in the order
More informationUltra short throw lens installation
Ultra short throw lens installation The ultra short throw lens 0.36 UST GS (P/N: 140-133108-XX) allows you to position your projector as close as possible to your screen or display. Unless otherwise indicated,
More informationTailgates Conracks Sunshades
Aluminum Accessories Tailgates Conracks Sunshades 15168 BACKUP CAMERA KIT 2009 THRU 2013 Ford F-150 NOTE: This kit is ONLY for Ford F-150 pickups that already have the factory back up camera option The
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationFor documentation the instrument is available with a trinocular head which permits mounting of a video or digital camera system.
1. Introduction The PriorLux MET upright compound metallurgical microscope is a high quality instrument equipped with high resolution, chromatically corrected optics for excellent image quality in reflected
More informationTransit Color Light Signal. (6-3/8 Outer Lens Diameter)
645 Russell Street Batesburg, SC 29006 Service Manual 7080 Transit Color Light Signal (6-3/8 Outer Lens Diameter) Installation, Operation and Maintenance November, 997 997, Union Switch & Signal Inc. Printed
More informationMK-101 TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:
MK-0 TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS CAUTION: Read all safety and operating instructions before using this equipment Enter the Serial Number of your new saw in the space below. The Serial
More informationPrinthead alignment. 1. Turn the printer off. 2. Remove the top cover. See Additional information top cover removal on page 8.
Printhead alignment Warnings: Whenever a printhead is replaced, it is necessary to perform the Mechanical alignment. Then, if a black printhead is replaced, perform the Black Printhead electronic alignment
More informationTerminal Equipment Controller Enclosure
Document No. 550-196 Terminal Equipment Controller Enclosure Product Description A Terminal Equipment Controller enclosure is a general-purpose metal cabinet with a removable cover that houses an electronic
More informationDear user. You will find actual information about our products on Seite 1 / 6
User manual THALES EASY Dear user Thank you for using the THALES EASY. This tonearm is designed differently than all other tonearms. If you follow this manual accurately the most precise analogue playback
More informationM40 Microscope User s Manual
M40 Microscope User s Manual for M40 and M40RT Microscope Components: Trinocular Port Eyepieces Beam Splitter Field Diaphragm Adjustment Aperture Diaphragm Adjustment Filter Slots Analyzer Polarizer Hex
More informationRSS Series Wired Electronic Ballasts
RSS Series Wired s Specifications Charts RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz No. of Lamp Circuits
More informationEPILOG LASER Table Mountain Parkway Golden, Colorado Phone FAX
EPILOG LASER 16371 Table Mountain Parkway Golden, Colorado 80403 Phone 303-277-1188 - FAX 303-277-9669 www.epiloglaser.com Procedure Title: Replacing the Optics in your FiberMark Laser Engraver Tools Needed:
More informationOperating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High
Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical
More informationArtisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment
Looking for more information? Visit us on the web at http://www.artisan-scientific.com for more information: Price Quotations Drivers Technical Specifications. Manuals and Documentation Artisan Scientific
More informationHow to build an Olympus D-360L Trail Camera using the PixController Universal "Digital Trail Camera Kit" w/ RS-232-U PIC Chip
Copyright, PixController, Inc. http://www.pixcontroller.com, all rights reserved. How to build an Olympus D-360L Trail Camera using the PixController Universal "Digital Trail Camera Kit" w/ RS-232-U PIC
More informationJAN 16 Rev B
ANSI C136.41-2013 Rotatable Dimming Receptacles Application Specification 20 JAN 16 Rev B NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters
More informationTubeMount system. Section 11 (pp.53-59) Breadboards and bases. Section 12 (pp.60-62) Stages and rod system. Section 13 (pp.63-70)
OPTOMECHANICS - introduction 5 Optomechanics - introduction There are basically two ways of mounting an optical system enclosed or open. Enclosed systems,such as an ordinary microscope,are light- and dust-tight,rigid,
More informationOcé User manual. Océ CS2024. Quick Start Guide
Océ User manual Océ CS2024 Quick Start Guide Océ Technologies B.V. Copyright 2005, Océ-Technologies B.V. Venlo, The Netherlands. All rights reserved. No part of this work may be reproduced, copied, adapted,
More informationSurvival Laser SL-002PB Laser Parts Bundle w/g-1 Lens Assembly & Operation Instructions
Survival Laser SL-002PB Laser Parts Bundle w/g-1 Lens Assembly & Operation Instructions WARNING: READ ALL INSTRUCTIONS AND THE ENCLOSED SAFETY PRECAUTIONS BEFORE ASSEMBLY AND USE Assemble and use these
More informationReplacing the Billboard Diagnostic Camera
Replacing the illboard Diagnostic Camera (PN 1109502701SP) The billboard diagnostic camera is a compact camera used to transmit live video streams with high image rates that can be viewed from a remote
More informationQuick Start Guide. Mounting the Essential Plus and Elite
Quick Start Guide Congratulations on purchasing an Essential Plus or Elite access control system. This Quick Start Guide provides simple instructions on how to get the system up and running. For more detailed
More informationInstalling a Power over Ethernet injector
Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart
More informationRSS Series Wired Electronic Ballasts
REV 02/16 RSS Series Wired s Specifications Charts RSS Installation Wiring Diagrams RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline
More informationMounting DIGITAL DISPLAY
Mounting The Class digital display mounts in a. by. cutout. Overall area necessary for installation is. by.. Two 0.0 diameter holes are provided for mounting screws..0".0..0.900 Ø 0.0" () HOLES."." DIGITAL
More informationStarsysXD Assembly INSTRUCTIONS FOR USE. For Enclosed Shells and Angular Adjustable qwikslot TM Wire Shelves DOUBLE WIDE - MOBILE UNIT
INSTRUCTIONS FOR USE StarsysXD Assembly SINGLE WIDE - MOBILE UNIT DOUBLE WIDE - MOBILE UNIT TRIPLE WIDE - MOBILE UNIT Cart Load Capacities: Adjustable qwikslot TM Shelves: Single Wide = 300 lbs. (136 kg)
More informationTCM-4 Data Logger Battery Replacement Instructions
TCM-4 Data Logger Battery Replacement Instructions These instructions apply to the following product: TCM-4 Shallow Water Current Meter These instructions assume that the user has purchased a TCM-4 Battery
More informationRSS Series Wired Electronic Ballasts
RSS Series Wired s Specifications Charts RSS Series Electronic Sign Ballasts Minimum starting temperature is -20 F (-30 C). For use with T12 HO, T8 HO, and Slimline 120 Volts, 50/60Hz Per Circuit Combined
More information12 MODULE BAR ASSEMBLY INSTRUCTIONS EL3H12AØØ(x)
ASSEMBLY INSTRUCTIONS MOUNTING INSTRUCTIONS Before starting the installation make certain you have the correct bracket for your application. A universal Deck/Dash mount bracket is supplied. For other mounting
More informationMicroscopic Imaging Research Station (MIRS) Assembly Guide. Version 1.0.0
Microscopic Imaging Research Station (MIRS) Assembly Guide www.adsyscontrols.com Adsys Controls, Inc.2012 Version 1.0.0 I. Assembly of the Adsys Controls MIRS system This document explains the assembly
More informationERGONOMIC MODULAR RAIL V3 M-LOK. ALG Defense 800 East Walnut Street North Wales, PA algdefense.com
TM ERGONOMIC MODULAR RAIL V3 M-LOK ALG Defense 800 East Walnut Street North Wales, PA19454 610.635.8937 algdefense.com TM ERGONOMIC MODULAR RAIL V3 M-LOK PACKAGE CONTENTS Ergonomic Modular Rail V3 with
More informationLNS-S10/LNS-T10/LNS-W10/LNS-T11/LNS-W11
LCD Projector Lens Replacement Procedure Model Number LNS-S10/LNS-T10/LNS-W10/LNS-T11/LNS-W11 Notes on Lens Replacement Lens replacement should be performed by the qualified service personnel. It should
More informationConnectivity Products
Cable Glands Strain Relief Snap-In Labels Lock Nuts Torque Wrench Protective Sleeves U2 U5 U5 U6 U7 U8 Features NPT and PG thread cable glands in nylon or metal materials Locknuts in multiple thread sizes
More informationMAKE YOUR OWN WEB CAM MICROSCOPE
STEP-BY-STEP INSTRUCTIONS COMPONENT DIAGRAMS KEY VOCAB EXPLAINED TOOL KITS, HINTS & TIPS MAKE YOUR OWN WEB CAM MICROSCOPE f=3.85mm Megapixel 10X Digital Zoom MEET YOUR WEB CAM Did you know that the first
More informationInstalling 6 Indexer: PRS Standard Tools
888-680-4466 ShopBotTools.com Installing 6 Indexer: PRS Standard Tools Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Overview...5 Installing the
More informationCable clips and ties
H 130 Cable clips and ties Cable clip with driven nail white colour O P brown colour 50 25 Type for cable O - round P - flat Nail dimension lenght / diameter H.7001 H.7001-50 H.7001-25 3 mm O 18 / 2 H.7001B
More informationPrint Head Replacement and Adjustment Guide for the CD Printer Revision C
Print Head Replacement and Adjustment Guide for the CD Printer 110488-001 Revision C Rimage is the trademark of the Rimage Corporation. Perfect Image is a registered trademark of the Rimage Corporation.
More informationFEF368GBD FEF368GQD FEF368GSD
Product No. BD QD SD Series 30" f/s elec 30" f/s elec 30" f/s elec Color black bisque white Market North America North America North America Owner's Guide 316417003 316417003 316417003 Installation Instructions
More informationMicroLab Component Holders
$ Mirror and beamsplitter mounts $ Lens holders $ Optical component cell systems $ Prism/tilt table $ Polarizer holders $ Fiber holders Stable optical component holders are critical for aligning any optical
More informationFLOE WIRELESS REMOTE ASSEMBLY INSTRUCTIONS KIT P/N
FLOE WIRELESS REMOTE ASSEMBLY INSTRUCTIONS KIT P/N 5-0083-00 TOOLS REQUIRED - 3/4" SOCKET - 3/4" WRENCH - /3" WRENCH - PHILLIPS SCREW DRIVER - TORQUE WRENCH INSTRUCTION P/N 6-0083-00 ISSUED: 3//7 SHEET
More informationTEC APO 200 OWNER S MANUAL
TEC APO 200 OWNER S MANUAL 2005 IMPORTANT - PLEASE READ THIS MANUAL BEFORE USING YOUR TELESCOPE SAFETY WARNINGS Do not look at the sun through the telescope! Viewing the sun through the telescope without
More informationP160 User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario
P10 User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario At Antec, we continually refine and improve our products to ensure the highest quality. So it's possible
More informationMoticam X 3. Start Guide. Included Parts
Moticam X 3 Start Guide This camera is a delicate instrument and should be handled with care. When not in use, please store the camera in a safe place with the dust cap attached. Do not let the camera
More informationLUMOTAST FK. General data. Content. Pushbuttons 1-9
General data TAST illuminated pushbutton range Illuminable pushbuttons and signal lamps with lamp socket T /T / 4. Please order lamps / LEDs separately. Mounting hole diameter 6.2 mm 42 V/00 ma max. Water-jet
More information