SR60 Busbar System 2/1. 2/2 Busbar routing. 2/3 Mounting components. 2/6 Accessories
|
|
- Owen Willis
- 5 years ago
- Views:
Transcription
1 SR60 Busbar System 2 2/2 Busbar routing 2/3 Mounting components 2/6 Accessories 2/1
2 SR60 Busbar System Busbar routing SR60 Busbar System Dimensions Order No. Price PG Weight PS*/ W x H x D mm mm mm 1 item kg Items Busbar support for SR60 busbar system for busbars with a bar thickness of 5 or 10 mm and a 12, 15, 20, 25 or 30 mm busbar height 60 mm busbar distance external 3-phase /55 8US AA internal 3-phase /55 8US AA internal 4-phase /55 8US AA N/PE busbar support for mounting onto busbar supports, can also be used as single support 1-phase /55 5SH /10 SR60 connecting terminal plate 3-phase, for conductors from 150 to 300 mm 2 (illustration without cover) 5SH Connector block for SR60 busbars 3-phase, for conductors from 35 to 120 mm 2 8US AA Accessories Terminals Conductor crosssection Tightening torque Order No. Price PG Weight PS*/ P. unit 1 item up to mm 2 Nm 1 item kg Items Terminals for one busbar 12 mm 5 mm JH JH JH JH JH JH JK JH JK JH JK3 061 Terminal for two busbars 12 mm 10 mm JH JH JK Extension terminal for 12 mm 5 mm busbar Busbar not included in delivery 1 set 6.0 8JK set Terminal for circular conductor 20 mm 5 mm to 30 mm 10 mm US BB /2
3 SR60 Busbar System Mounting components Size Rated current Rated Order No. Price PG Weight PS*/ voltage A V 1 item kg Items NEOZED SR60 bus-mounting base for busbar thickness 5 mm for NEOZED adapter sleeves D SG /10 excess width with clearance for wiring D SG /10 for busbar thickness 10 mm for NEOZED adapter sleeves D SG /10 excess width with clearance for wiring D SG /10 DIAZED SR60 bus-mounting base for busbar thickness 5 mm for use of DIAZED SR60 adapter rings DII SF /10 DIII SF /10 for use of DIAZED screw adapters DII SF /10 DIII SF /10 for busbar thickness 10 mm for use of DIAZED SR60 adapter rings DII SF /10 DIII SF /10 for use of DIAZED screw adapters DII SF /10 DIII SF / /3
4 SR60 Busbar System Mounting components Size MW Order No. Price PG Weight PS*/ 1 item kg Items NEOZED SR60 cover D SH /10 excess width with clearance for wiring D02 2 5SH /10 with double width for a larger clearance for wiring D02 3 5SH /10 DIAZED SR60 cover DII 2.3 5SH /10 DIII 3.2 5SH /10 with double width for a larger clearance for wiring DII 4.7 5SH /10 DIII 6.4 5SH /10 Size Thread for fuse Order No. Price PG Weight PS*/ links A 1 item kg Items DIAZED SR60 adapter rings only for DIAZED SR60 bus-mounting bases DII E SH SH SH SH SH SH DIII E SH SH SH SH SH SH SH SH SH NEOZED screw caps, adapter sleeves and fuse links, please refer to chapter "Low-voltage fuse systems", NEOZED fuse system. DIAZED screw caps, screw adapters and fuse links, please refer to Chapter "Low-voltage fuse systems", DIAZED fuse system. 2/4
5 SR60 Busbar System Mounting components Width Order No. Price PG Weight PS*/ mm 1 item kg Items SR60 LV HRC bus-mounting fuse base Size 000 and 00 with cover, top terminals, for 5 and 10 mm busbar thickness Terminals up to 70 mm 2 Rated voltage 690 V AC with saddle-type terminal connection 3NH with flat termination, screw M8 3NH I u for LV HRC Conductor crosssection Type of connection/ Order No. Price PG Weight PS*/ links adapter A Size up to mm 2 1 item kg Items Fuse switch disconnectors for SR60 busbars climate-proof, rated operational voltage 690 V AC delivered without LV HRC fuse links and top 3NP CK bottom 3NP CJ and 00 up to 2 70 top 3NP CE bottom 3NP CF and top 3NP CK (SIGUT terminal) bottom 3NP CJ and 1 max. 150 top or bottom 3NP CG max. 240 top or bottom 3NP CG max top or bottom 3NP CG For additional busbar adapters and fuse switch disconnectors, please refer to Chapter "Low-voltage fuse systems, LV HRC fuse systems, LV HRC fuse switch disconnectors". Rated current Rated voltage Order No. Price PG Weight PS*/ AC AC A V 1 item kg Items NEOZED SR60 bus-mounting switch disconnector for busbar thickness 5 and 10 mm for 3-phase busbar system Width: 1.5 MW Size D SG SR60 bus-mounting disconnector for 10 x 38 mm cylindrical fuses for busbar thickness 5 and 10 mm for 3-phase busbar system NW Auxiliary switch 1 changeover contact, 24 to 230 V AC, AC 2 A 5SH Lateral module for NEOZED SR60 bus-mounting switch disconnectors for better heat conduction at permanent loads over 35 A Width: 0.5 MW 5SH /5 Reducer for NEOZED fuse links D01 in the SR60 bus-mounting switch disconnector 5SH /5
6 SR60 Busbar System Accessories SR60 covers Length Order No. Price PG Weight PS*/ mm 1 item kg Items Base Height 230 mm, for 3 busbars SH mm, for 4 busbars 5SH Blanking cover Depth 32 mm SH Cover profile for busbars up to 30 x 5 mm US AA up to 30 x 10 mm 8US BA Edge H x W 17 x 36 mm, for 3 busbars SH x 36 mm, for 4 busbars 5SH Partition slotted H x W 17 x 86 mm SH End cover for busbar support, lateral Height 230 mm 5SH set 290 mm (1 set = 2 items) 5SH set End cover for busbar support, top 8US AC pole 8US AB Edge support and support for partition 5SH Support for blanking cover for blanking cover 5SH /6 7
SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More information5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009
Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens
More informationBusbar Systems. 10/2 Introduction. 10/3 General data. 40 mm Busbar Systems 10/6 Introduction 10/7 Base assemblies up to 400 A
Siemens AG 20 Busbar Systems /2 Introduction /3 General data 40 mm Busbar Systems /6 Introduction /7 Base assemblies up to 400 A mm Busbar Systems /8 Introduction /9 Base assemblies up to 630 A /13 Base
More informationSENTRON SIVACON ALPHA
SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 04/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution
More informationSENTRON SIVACON ALPHA
SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution
More informationSiemens AG Busbar Systems SENTRON. Configuration. Edition Manual. Answers for infrastructure and cities.
Busbar Systems SENTRON Configuration Manual Edition 2014 Answers for infrastructure and cities. Busbar Systems 2 Introduction 3 General data 8US 40 mm busbar systems 7 Introduction 8 Basic assemblies
More informationComponents for Distribution Systems
Components for Distribution Systems /2 Introduction Busbar adapter systems /4 General data /7 40 mm system / 60 mm system /12 Accessories /14 Project planning aids Door-coupling rotary mechanisms /23 General
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More information8WH5 Combination Plug-In Terminals
8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical
More informationSiemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.
3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationALPHA SIMBOX Small Distribution Boards
ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationNV disconnectors with fuses
NV disconnectors with fuses Horizontal fuse-switch disconnector type HVL size 00,, 2, and 4a Description Horizontal fuse-switch disconnector type HVL are designed to be used in most demanding fields of
More informationBasic Efficiency. NH Fuse-Bases 3-pole. NH Fuse-Bases up to 1500 V. NH Fuse-Bases 1-pole. NH Fuse-Bases, SILAS
Basic Efficiency up to 1500 V 1-pole 3-pole, SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 58 Accessories 60 Technical Data see page 63 NU System The EFEN successfully
More informationModular switch disconnectors and modular change-over switches
Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability
More informationSASY 60i Busbar System. SASY 60i Busbar System
Table of Contents SASY 60i Busbar System System up to 630 A for flat busbars System up to 1250, 1600 A for profile busbars Covers for 630, 1250 and 1600 A systems Feeder circuit adapters for 630, 1250
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More information3RP, 7PV Timing Relays
3RP, PV Timing Relays Overview Standards The timing relays comply with: EN 6021-3-3 "Environmental conditions" EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN 61000-6-2 and EN
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationAdd-on Residual Current Protection PBSM MW
SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm
ENERGY SAFELY SWITCHED SWITCHGEAR BUSBAR SYSTEM 60 mm SWITCHGEAR ENERGY safely switched About Grupa Apator Who we are? Grupa Apator is a dynamic Polish capital group, it currently includes 14 companies
More information- With PE/N terminals - For flush mounting devices with size 1 to DIN For circuit-breaker NZM... - Switch-disconnector N...
Distribution board enclosure with gland plates fitted KST... CI: Page 20/6 KST...: CI: Page 20/10 - With PE/N terminals - For flush mounting devices with size 1 to DIN 43880 Page 20/31 - For circuit-breaker
More informationMINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS
More informationFlat conductor adapter FI/LS Assembly instruction
Flat conductor adapter FI/LS Flat conductor adapter FI/LS 6 A Installation must be carried out by a person with electrical and technical knowledge and experiences (see DIN VDE 0620-1). Pre-tailored device
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationFast Bus Fast Bus Busbar System
Fast Bus Busbar System Contents Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming supply terminals /6 Copper busbar /6 Busbar
More informationFast Bus Busbar System
Busbar System Industrial Controls Product Catalog 2017 Section c o n t e n t s Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More informationLoad Feeders, Motor Starters and Soft Starters
Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line
More informationContactors and Contactor Assemblies
SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during
More informationLoad Feeders. Communication-capable load feeders
Load Feeders /2 Introduction Communication-capable load feeders ET 200S /4 ET 200S motor starters /8 Power modules for ET 200S motor starters /9 SIGUARD safety systems for ET 200S motor starters /10 ET
More informationControls Solid-State Switching Devices
Siemens AG 27 Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Relays /6 General data /7 3RF21 solid-state relays, single-phase, 22.5 mm
More informationSINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4
Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More information5SL Miniature Circuit Breakers
5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens
More informationMBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit
MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch
More informationMounting and Technical Data
Technical Information Mounting and Technical Data / ontent This document describes the technical data, the assembly and selection of cables for the D main distribution and. SM_SM--TI-en-30 Version 3.0
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class
More informationDIK 1,5. Extract from the online catalog. Order No.:
Extract from the online catalog DIK 1,5 Order No.: 2715966 Three-level initiator terminal block, cross section: 0.2-2.5 mm², AWG: 30-14, width: 6.2 mm, color: gray Commercial data EAN 4017918061715 Pack
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationInsulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals
Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Technical Data Type: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Article number * ) : 00636 00637 0063987 00614
More informationALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP
ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type
More informationDOK 1,5-2D. Extract from the online catalog. Order No.:
Extract from the online catalog DOK 1,5-2D Order No.: 2717139 Sensor/actuator terminal block, Cross section: 0.2 mm² - 4 mm², AWG: 24-12, Connection type: Screw connection, Width: 6.2 mm, Color: gray,
More informationUK-SI. Extract from the online catalog. Order No.:
Extract from the online catalog UK-SI Order No.: 3118012 Fuse terminal block for cartridge fuse inserts 5 x 20 and 5 x 25, cross section: 0.2 -, width: 8.2 mm, color: black Commercial data EAN 4017918092856
More informationSiemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices
Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationINSTALLATION GUIDE NP800R
INSTALLATION GUIDE ICE - 11, rue Marcel Sembat - 94146 ALFORTVILLE CEDEX - France TEL. : (33) 01 41 79 76 00 - FAX : (33) 01 41 79 76 01 E-MAIL : contact@icelec.com SITE WEB : www.groupeice.com File: A662A
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationFlexible connectors made out of copper- and aluminium foils
Fleible connectors made out of copper- and aluminium foils We offer a wide range of standardized laminated connectors as well as multifarious designs according to your drawings or wishes. All articles
More informationDIK 1,5-LA 24RD/U-O. Extract from the online catalog. Order No.:
Extract from the online catalog DIK 1,5-LA 24RD/U-O Order No.: 2715995 Sensor/actuator terminal block, Cross section: 0.2 mm² - 4 mm², AWG: 24-12, Connection type: Screw connection, Width: 6.2 mm, Color:
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationSENTRON SIVACON ALPHA
SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationdv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2
dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical
More informationAS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45
Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationUT 2,5-PE. Extract from the online catalog. Order No.:
Extract from the online catalog UT 2,5-PE Order No.: 3044092 Feed-through modular terminal block, Type of connection: Screw connection, Screw connection, Cross section: - 4 mm², AWG 26-12, Width: 5.2 mm,
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationOvervoltage Protection Devices
Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type
More informationZB4BW061 light block with body/fixing collar for BA9s bulb 250V 1NO
Characteristics light block with body/fixing collar for BA9s bulb 250V 1NO Product availability : Stock - Normally stocked in distribution facility Price* : 55.00 USD Main Range of product Product or component
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationInsulated Enclosure KU 4087, KU 4088 KU 4089 to DIN for installation in distribution cabinets or surface mounting
Insulated Enclosure KU 4087, KU 4088 KU 4089 to DIN 43 880 for installation in distribution cabinets or surface mounting Width 17,5 / 35 / 70 mm 8 / 16 / 32 plus-minus-terminal screws with self raising
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationUK 6 N. Extract from the online catalog. Order No.:
Extract from the online catalog UK 6 N Order No.: 3004524 Feed-through modular terminal block, Type of connection: Screw connection, Cross section: 0.2 mm² - 10 mm², AWG 24-8, Width: 8.2 mm, Color: gray,
More informationUK 5-HESILA 250. Extract from the online catalog. Order No.:
Extract from the online catalog UK 5-HESILA 250 Order No.: 3004142 The illustration shows version UK 5-HESI Fuse terminal block for cartridge fuse insert, cross section: 0.2-4 mm², AWG: 26-10, width: 8.2
More informationIndustrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,
Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,
More informationPower distribution systems - accessories
Connections and terminals Line terminal X 221 3 01 Power-D-Box with sockets pre-wired Line terminal (max. 63 A) X 221 3 01 14.551 max. tightening torque 3.0 Nm 15.591 busbar X1, X2 blade terminals 6.3
More informationC-POWER AC AUTOMATIC CONTROL
Issue 1 Print 1 C-POWER AC AUTOMATIC CONTROL INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model: 93 ACMC100I A Charles Industries, Ltd. All rights reserved. Printed in the United States of America. Issue
More informationXB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center
Characteristics key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center Main Range of product Product or component type Device short name Mounting diameter Oct 4, 2018 Harmony XB7
More information4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data
Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationIndustrial Hydraulics FAQs
Industrial Hydraulics FAQs FAQ Title: Z versus K or K0 in model code Category: Proportional & Servo Valves Sub-Category: Directional Control Valves Bosch Rexroth Corporation Hydraulics 5 City Line Road
More informationXL 4000 metal free-standing enclosures and cable compartments
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL metal free-standing enclosures and CONTENTS PAGE 1. General characteristics...1 2. Range...2 3. Overall dimensions...2 4. Equipment...3
More informationUT 6. Extract from the online catalog. Order No.:
Extract from the online catalog UT 6 Order No.: 3044131 Feed-through modular terminal block, Type of connection: Screw connection, Screw connection, Cross section: 0.2 mm² - 10 mm², AWG 24-8, Width: 8.2
More informationonlinecomponents.com
Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationXB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals
Characteristics round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals Complementary Height Width Depth Terminals description ISO n 1 Product weight Main Range of product Product
More informationPRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters
Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationOvervoltage Protection Devices
Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge
More informationOvervoltage Protection Devices
Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type
More informationISOMETER isopv with coupling device AGH-PV
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for photovoltaic plants up to AC 793 V/DC 1100 V Vorläufiges Datenblatt IsoPV_D00024_02_D_XXEN/07.2018 ISOMETER with coupling
More information